12-1462 (SFD)I f t P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 j VOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 2/28/13 Owner: RICHARD.& ALEXANDRA ALBERS THE ALBERS FAMILY TRUST DETACHED .49855 RANCHO SAN FELIPE LA'QUINTA, CA 92253 Contractor: Applicant: Architect or Engineer: ALBERS CONSTRUCTION CO, C. P.O. BOX 238 LA QUINTA, CA 92253 (760)771-9954FEB 2013 Lic. No.: 769229 CITY OF LA QUINTA FINANCE DEPT. --------------------------------------------------------------------`----------------------------- LICENSED CONTRACTOR'S DECLARATION IWORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect._ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License lass: B License No.: 769229 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ' 1� �� // /� — issued. Date: Contractor: IJ -e Vi Cc9-�.t �' I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: ' I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 9028371-2012 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to- _• I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or Z 3700 of the Labor Code, I shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violatioh of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: -Date: �� 3 �f/Applicant: �. — (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the _ improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who.builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 1 am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000)• IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for - whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. .•� 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this unty t enter -upon the above-mentioned pro a 'nspection purposes. f �I. � Date: VSignature (Applicant or Agent): Application Number: 1'2-00001462 Property Address: 80270 VIA CAPRI APN: 777-100-073- - - Application description: DWELLING - SINGLE FAMILY Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 474471 j VOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 2/28/13 Owner: RICHARD.& ALEXANDRA ALBERS THE ALBERS FAMILY TRUST DETACHED .49855 RANCHO SAN FELIPE LA'QUINTA, CA 92253 Contractor: Applicant: Architect or Engineer: ALBERS CONSTRUCTION CO, C. P.O. BOX 238 LA QUINTA, CA 92253 (760)771-9954FEB 2013 Lic. No.: 769229 CITY OF LA QUINTA FINANCE DEPT. --------------------------------------------------------------------`----------------------------- LICENSED CONTRACTOR'S DECLARATION IWORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect._ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License lass: B License No.: 769229 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ' 1� �� // /� — issued. Date: Contractor: IJ -e Vi Cc9-�.t �' I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: ' I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 9028371-2012 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to- _• I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or Z 3700 of the Labor Code, I shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violatioh of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: -Date: �� 3 �f/Applicant: �. — (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the _ improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who.builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 1 am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000)• IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for - whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. .•� 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this unty t enter -upon the above-mentioned pro a 'nspection purposes. f �I. � Date: VSignature (Applicant or Agent): 1. . Application Number . . . . . 12-00001462 Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy'Type DWELLG/LODGING/CONG <=10 Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 4.00 FIRE SPRINKLERS YES GARAGE SQ FTG 995.00 PATIO SQ FTG 380.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 5433.00 Permit . . . BUILDING PERMIT Additional desc .. Permit Fee 1952.00 Plan Check Fee 1268.80 _ Issue Date Valuation 474471 Expiration Date 8/27/13 • Qty Unit Charge Per Extension BASE FEE 639:50 375.00 3.5000 ------------------------------------------------------------------------------ THOU BLDG,100,001-500,000 1312.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 240.06 Plan Check Fee 60.02 Issue.Date Valuation "0 Expiration Date 8/27/13 Qty Unit Charge Per Extension BASE FEE _ 15.00 5433.00 ..0350 ELEC NEW RES - 1 OR 2 FAMILY 190.16 995.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 19.90 ' 1.00 15:0000 EA ELEC TEMPORARY POWER POLE 15.00 --------------------------------- ------------------------------------------ - Permit . . . GRADING PERMIT Additional desc . Permit Fee . . 15.00 Plan Check.Fee .00 Issue Date . . . . Valuation 0 Expiration Date 8/27/13 Qty Unit Charge .Per Extension BASE FEE 15.00 Permit . . . . . : MECHANICAL LQPERMIT Application Number . . . . . 12-00001462 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 163.00 Plan Check Fee 40.75 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/27/13 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 9.0000 EA MECH FURNACE <=100K 45.00 2.00 9.0000 EA'MECH B/C <=3HP/100K BTU' 18.00 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 33.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 -Permit . . . PLUMBING Additional desc . Permit Fee 219.75 Plan Check Fee 54.94 Issue Date Valuation 0 Expiration Date 8/27/13 Qty Unit Charge -Per Extension BASE FEE 15.00 24.00 6.0000 E.A. PLB FIXTURE 144.00. 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 15.00 .7500 EA PLB GAS PIPE >=5 11.25 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 5433 SF SFD. 2010 CODES.W/.FIRE SPRINKLERS. 2008 DIF. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, . SPA, BBQ'.S, FIRE PIT and DRIVEWAY APPROACH** ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 686.18 BLDG STDS ADMIN (SB1473) 19.00 DIF COMMUNITY CENTERS -RES 104.00 DIF CIVIC CENTER - RES 1089.00 ENERGY REVIEW FEE 126.88 DIF FIRE PROTECTION -RES 612.00 DIF LIBRARIES - RES -334.00 MULTI -SPECIES (MSHCP) FEE 1254.00 DIF PARK MAINT FAC - RES 51.00 DIF PARKS/REC - RES .1773.00 LQPERMIT LQPERMIT Application Number , . . . . 12-00001462 -----------------_-_------------------------------------_------- Other Fees .. . . . . . . STRONG MOTION (SMI-) RES ----------- 47.45 DIF STREET MAINT FAC -RES 158.00 DIF TRANSPORTATION - RES 3592.00 Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 2589.81 .00 .00 2589.81 Plan Check Total 1424.51 .1000.00 .00 424.51 Other Fee Total 9846.51 .00 .00 9846:51 Grand Total 13860.83 1000.00 .00 12860.83 LQPERMIT PO. BOX 1504 APPLICATION ONLY Building78-495 CALLE TAMPICO Address 802.70 VIA IA eAPR Q LA QUINTA, CALIFORNIA 92253 Owner 1CKARr-) A. AL-13F-9,5BUILDING: TYPE CONST. �^ N OCC. GRP. 973LU I Mailing -7 VIA IA CAFN A.P. Number -777 (O0 — c-733 Address&-2--10 City IZIP Tel. Legal Description LQ� 51 olhd 554 !88a 2�j$�- . -2 I �.A(WIMTA F1,2253546797 M B -7/o Co ra r QI �L Project Description �RS CO i•1sT�zUG1'► ©til 5 le, :Favn; I . 3 $a4m l h Address2�4 PJ US C-2-SOil W [>G)tb 7 A . City Zip Tel. � L)i zA °1229- -10-71J-61V7 State Lic. City Sq. Ft. f. No. No. Dw. & Classif.,6 2.2`� —'g Lic. # Size 5`� S' 1' Stories Units Arch., Engr., New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Designer JEKF`r W. S H Et�Nl, ,N Address Tel. 81677 ShAPOW AVE -160- 271-707 City Zi State IN1710 8220 I Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed d r provisions of Chapter 9 (commencing with Section 7000) of Divi s' n of B ines a Professions Code, and my license is in full f rce and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also PERMIT AMOUNT requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis Plan Chk. Dep. Dn - for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than live hundred dollars (8500). Plan Chk. Bal. ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- Const. sions Code: The Contractor's License Law does not apply to an owner of properly who builds or improves thereon and who does such work himself or through his own employees, provided Mech. that such improvements are not intended or offered for sale. If, however, the building or im- N I n I I I fl l l provement is sold within one year of completion, the owner -builder will have the burden of Electrical r'� proving that he did not build or improve for the purpose of sale). I U�1 —�I I I II ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct Plumbingrr the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does S.M.I. III III I II not apply to an owner of property who builds or improves thereon, and who contracts for such - 1` •- ^, - projects with a contractor(s) licensed pursuant to the Contractor's License Law)J Lu l L Grading — Iff)l ❑ 1 am exempt under Sec. B. & P.C. for this reason Driveway Enc. I C--=. j ... r LIQ L,ttyINJA Infrastructure ^,f f A 011^ ' M -r Date Owner - _ WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy t1�roof. (Sec. 3800, Labor Code.) Policy No.9 OZgi7 i Company ST�Y�Y-i.i�/✓� 0 Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTIO OM TOTAL WORKERS'COMPENSATIO SURANCE (This section need not be completed�ecome or one hundred dollars (8100) valuation REMARKS or less). I certify that in the performancewhich this Permit is issued, I shall not employ any person in any manner so bject to Workers' Compensation Lawsof California. Date Owner NOTICE TO APPLICANT.' If, er making this Certificate of Exemption you should become subject to the Workers' 015mpensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. ZONE: BY: Minimum Setback Distances: CONSTRUCTION LENDING AGENCY Front Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work Rear Setback from Rear Prop.Line for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Side Street Setback from Center Line Lender's Address Side Setback from Property Line This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. FINAL DATE INSPECTOR I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Issued by: Date Permit Signature of applicant Date Mailing Address Validated by: City, State, Zip Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Coachella Valle Unified School District Valley This B., For District Use Only ' 83=733 Avenue 55, Thermal, CA: 12274 DEVELOPER FEES PAID (760),398-5909 — Fax. (760) 398-1224 ; AREA: .. .. .. AMOUNT .. - . LEVEL ONE AMOUNT: LEVEL TWO AMOUNT:- MITIGATION AMOUNT: COMMAND: AMOUNT: DATE: RECEIPT: CHGCK#: INITIALS ' CERTIFICATE OF COMPLIANCE (California Education Code:17620) Project Namn :he Hideaway Date: February 28, 2013 -- ' Owners Name:: Bill &:Alexandra Albers : Phone No. Project Address: 80-270 Via Capri, La Quinta, CA Project Description: Single Family Dwelling APN: 777=100-073 Tract Lot s:. .:.... . Type of Development::.: Residential X-9 Commercial 'Industrial - Total Industrial:Total Square Feet of Building Area: 5433s ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this -statement under penalty of perjury and further represents that he/she is. authorized to sign on behalf of the owner/developer.: Dated: February 28; 2013 Signature: SCHOOL DISTRICT'S ,REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) . Education Code, .:: Gov. Code Project : Agreement; Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87. Requirement , Note: Number of Sq.Ft., _; ;.5433 Pursuant to AB 181;any;room additions or enclosures of 500 sq. ft. or less are exempt from developer fees.- Any. mobile Amount per Sq.Ft. $3.20. :. homes being relocated within:the same school district's.: Amount Collected. $17385.60 jurisdiction are. exempt from developer fees.. . Building Permit Application Completed: Yes/No By: Elsa -F. Esqueda, Director. of Facilities and Maintenance Certificate issued by:* Laurie Howard; Secretary . Signature: 1 .NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES . . Section 66020 of the. Government Code asserted by Assembly Bill 3081, effective:January 1, 1997, requires that this District provide.(!) a written notice to the project appellant, at the time *:of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to.protest.the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 660209f the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or. the validity thereof; commences with the payment of:the fees or performance of any other requirements as described in section 66020'of the Government code: Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in: part: prior to issuance of a Certificate of Occupancy., :As in the latter, the 90 days starts on the date hereof. This Certificate of . Compliance is valid for thirty- (30) days from the.date:of.issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/ntydecs/de.vfees/certlificate ofxompliance form updated 3-2007 11/2010 CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed [Address(s): elow are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. ate: 1 114-5113 Developer: % I%f �r S%i2vcT % �,� Co .Zn L. act No.: 749 Tract Name: I �.eL4. v 60-C11V4 Lot No.(s): 96277 0 `,ck. Com, �,' �� C.f �u S 3 `/ A � � � � Phone Number: ( The following are the requirements for Public Works Clearance to authorize issuance of a building permit f om tthheED Building & Safety Department: ❖ USTOM HOMES: PROVIDE ITEMS #2. #3. #4_ #5 & #7 RF1 nW JAN 3 0 2013 ❖ TRACT HOMES: PROVIDE ITEMS #1 #2 #3 & #5 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS 01 02 #3 #5 & #7 BELOW •: WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW BY: 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. n vs� Attach geotechnical certification of grading plan compliance including, compaction reports from a licensed Soils Engineer. Recently rough graded residential developments ,which have a previously approved geotechnical certification are exempt from this requirement. X Attach recorded. final map or title information/grant;deed showing proposed building, locations,are.legal lots:, 4' Complete the attached <1 acre per lot or infill project Fugitive,Dust Control project information=form, PM10?'plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A,current.PM10 certification number is required. Attach a copy of the rough or precise! ' rading plarirto the Public Works Department showing building location(s) . for pad elevation verification. Z flood zone evelopments will require an approved flood plain development plan. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. Complete..and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved" building construction projects require eitherr-a WQMP or a completed WQMP exemption form.:: Approved maps/plans may be viewed at the following link: http://www.la-ouinta.org/PlanCheck/m search.asp I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. 4111-1 11 Recommended by:, Date: Public Works Distribution: Green Sheet to Planning Department �® ( � Green Sheet to Building &Safety FF ( ) B 1 co,C`--'';°} 1 013 Declined for approval for reason(s) as follow(s), please correct and resubmit: u4f - 44 QC/ oK /4/r 3 �0 A. T:\Checklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than t Acre Revised 9-25-09.doc City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement <1 or Infill Project Project Information /acre/lot ontractor: q l� uS `�r� S�Yt�' ` �J C'' II tProjectV �( t KLe- Project Phase me: (check one) S Sact/Lot Numbers: i, Oji SLI " Construction Demolition Project Street Address: `l t+ afi C _ Total Acres in Active Construction (<1 acre per Anticipated Start Date: 02/ 0/jaAnticipated Completion Date: <Z/ 3 / 13 Lot): t PM10 Contact tcontrol Is required 24 hours a day, , 7 days.a week, regardless const listed below is responsible for dust control during business and Information constlease ruction status. Person non-business hours. �J Name:.c'R Title: 0 01JT4A_Z_T hL �lLc�St l�t� r Company Name: tr� t 1S C�►S LTl.O� C_ Mailing Address: �($ S S IZ-t�.tic,L� J S w� , State, ZIP Code: LCI (�vt w CJS- Ct ZZ S 3 Prima Phone #: c � d 2 Fax M -1 �l t � � 3 -3 24 Hour Emergency Phone#: Cell Phone M i `i - o i� 1b 2`r S' cD �4r' + i �' k" o ry Email Address: PM10 Certificate #: The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402_201, 203 and PERP; Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. •3 Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance; regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; Shall take all necessary precautions to,minimize dust, even if additional measures beyond those listed, in the dust control plan are necessary; Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; •: Shall hold harmless the City/Countyand its representatives -from liability for any actions. related.to jhhls dust control plan or any City/County initi ted abatement activities. C z s- Signature of Property" Owner or Authorized Representative Date T -.\Checklists - Forms & Applicatlons\Forms & ApplicaUons\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc Plan Submittal Job Site Ad Owners N Number, Street, or PO City, State, Postal C Owners Phone Nun Owner's E -Mall Add Building Permit Number: Project Description: SFR Exempt: O (Materials may contain hazardous wastes and are not subject to recycling provisions) . Construction Debris Management Plan 1/28/2013 80270 \Tia Capri Richard Albers RECEIVE 80270 via Capri La Quinta, Ca 92253 FEB 4 2013 ,...�-�:� :.- - h ::..�•�:�� �.� �Y:OF �LA:QUINTA ��,.:.�.:.� .:>�- :. r�-.�-. '8ilt'Atbers" _. r -N Project Managers Phone Number 760.774-6787 T COMMUNITY DEVELOPMENT Project Managers E -mall Address b,albara0learthlink.net Builder / Contractor Albers Construction Number, Street or PO Box 49855 Rancho San Felipe city, state, Postel codel La Quinta, Ca 92253 Project Square Footage 6,428 City Approval By ' Date of City Approval 3 Materials To Be Discarded: Product Tons Trash 12.21 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Brick/Block 0.00 Recyclable Piaster 1.29 Cardboard 2.12 Recyclable Scrap Metal 0.00 Commingled 0.00 Recyclable Tile (floor) 1.09 Concrete 0.51 Recyclable Tile (roof) 0.00 Drywall 0.38 Racyclable Wood 18.07 Donated / Reuse* I 0.00 Racyclaable Landscape Debris 0.00 "Describe Items Totals: Recycle Trash Projected Dlversion: 21.5 12.2 I understand itis the property owners responsibility to submit copies of wolght tickets or reaelpts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (OMP) for the above named project shell guarantee that at least 60% of the jobslte waste Is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project In accordance with this plan. This OMP Is Issued In the name of the properly owner(s) and shall remain their property throughout the construction and/or demolition . project A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still Issued In the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The prop" owner(s) and generid contractor shall be kept Informed of the diversion progress through bbmonthly reports. If self-haulin , refuse at f this project site must be taken to an approved recycler or transfer station. /Z:P//3 Owner / Developer / Projoct Manager / Superintendent Date A it 0� PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA, MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUX CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT.5 RIVERSIDE COUNTY FFIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF.FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. 1 201, Palm Desert,, CA 92211-4131 • Phone (760) 863-8886 •' Fax (760) 863-7072 www.rvcfiire.org R,Er-xivcr-� January 7, 2013 Thorpe Sprinkler Design FEB 4 2013 CITY OF LA Re: Residential Fire Sprinkler Plan Review COMM(JN17y 4VINTq LAO -I2 -RS -071 Albers Residence 80-270 Via Capri La Quin a, �i VELOPMENT The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved1with the following conditions: A minimum of three spare fire sprinklers of each type and temperature rating along with a sprinkler wrench should be located in a spare head cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all control valves. A warning sign, with minimum I/ inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. ' The following inspections/tests are required to be witnessed,by the Fire Department Planning Division staff: (a) Overhead Rough and Hydrostatic test: All piping shall be visible and pumped at normal operating pressure. (b) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Departmen to schedule inspeption. Sincerely, Jaso Stubble Fire Safety Specialist O rt EsGil Corporation In Tartnerskip with Government for Building Safety DATE: FEB: 12, 2013 , ❑ APPLICANT 13'JURIS. JURISDICTION: "LA QUINTA ❑ PLAN REVIEWER ❑ FILE PLAN CHECK NO.: 12-1462 SET: II PROJECT ADDRESS: 80-270 VIA CAPRI PROJECT NAME: SFR FOR.ALBERS ® The plans transmitted herewith have been corrected where necessary and substantially comply . with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have- significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being- held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for th&jurisdiction'to forward, to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® EsGil Corporation staff did not advise the applicant that the plan check has been completed. ❑ EsGil Corporation staff did advise the applicant that the plan check has been completed.. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person ❑ REMARKS: 'E'R 1VE By: ALI SADRE, S.E.' Enclosures: i FEB] 2 2013 EsGil' Corporation cm. 01 ❑ GA E] EJ ❑ PC 2/4 ro�MUtVITY E Q �I(VTq OPNjEIVT 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858)560-14681* ,Fax (858)560-1576 Sladden Engineering 45090 Golf. Center Parkway, Suite F, Indio, CA Y92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 January. 24, 2013 Project No. 544-13010 13-01-030 Albers Construction Company, Inc. RECE/VED P. O. Box 238 La Quinta, California 92247 FEB 4 2013 Subject: Foundation Plan Review . CIl'Y OF LA 'QProposed Albers Residence CO DEVELOPMEN 80-270 Via Capri MENT The Hideaway La Quinta, California Ref: Geotechnical Update prepared by Sladden Engineering dated January 16, 2013; Project No. 544-13010, Report No. 13-01-018 As requested, we have reviewed the Foundation Plans and Details prepared by RA Structural Engineering for the proposed custom residence to be located at 80-270 Via Capri within the 4 Hideaway development in the City of La Quinta, California. Based on our review, it is our opinion that the recommendations provided in the above referenced Geotechnical Update report and previous geotechnical reports have been properly incorporated in these plans. If you have questions regarding' this memo or the referenced report, please contact the undersigned. - Respectfully submitted, SLADDEN ENGINEERING CITY OF LA nUINTA S�oNgl BUILDING & SAFETY DEPT. RETTL.- F APPROVE® Brett L. Anderson ANDERSON -FOR CONSTRUCTION No. 045389 Principal Engineer Exp. 9/3a�4 ` . -CIVIL LqZ BY� ENGINEERING Letter/gvm � '15;> f=f Copies: Q Albers Construction Company, Inc. Sladden Engineering F 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 January 16, 2013 Project No. 544-13010 13-01-018 Albers Construction Company, Inc. P. O. Box 238 La Quinta, California 92247 Project: Proposed Albers Residence 80-270 Via Capri ' The Hideaway m . La Quinta, California Subject: Geotechnical Update Ref: Geotechnical Update prepared by Sladden Engineering dated October 26, 2009; Project No. 544-09165, Report No. 0-10-258 Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated September. 22, 2000; File No. 07117-10, Report No. 00-09-772 - Report of Testing and Observation During Rough Grading prepared by ESS dated August 28, 2002; File No. 07117-11, Report No. 01-07-718 Report of Testing and Observation During Rough Grading prepared by Sladden . Engineering dated October 12, 2003; Project No. 544-2199 Report No. 03-10-647 - As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed custom residence.' The project site is located at 80-270 Via Capri within the Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight wood -frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded during the rough grading of the Hideaway project site and was subsequently "regraded. The rough grading included over -excavation of the native surface soil along with the placement of engineered fill soil to construct the building pads. The regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads to the current configurations. Some additional over -excavation was performed in' areas where the building envelopes were reconfigured. The most recent site grading is summarized in the referenced Report of Testing and Observations During Rough Grading prepared by Sladden Engineering along with the compaction test results. The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced ,reports, it is our opinion that the structural values included in the referenced grading report prepared .by Sladden Engineering remain applicable for the design and construction of the proposed residential structure foundations. s' r January 16, 2013 -2- Project No. 544-13010 13-01-018 Because the lot has been previously rough graded, the remedial grading required at this time should be minimal provided that the building falls within the previously assumed building envelope. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing, pressures recommended in the referenced grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each additional 6. inches of depth may be utilized if desired. The maximum allowable bearing. pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance' along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is non -expansive 'and falls within the "very low' expansion category in accordance with 2010 California Building Code (CBC) classification criteria. Slab thickness and reinforcement should be determined by the structural engineer. We recommend a minimum floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder consisting of a polyvinyl chloride membrane such as 10 -mil Visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface can not be achieved by grading, consideration should be given to placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the membrane. Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is So, generally described as stiff soil. The following presents additional coefficients and factors relevant to seismic mitigation for new construction based upon the 2010 California Building Code (CBC). Sladden Engineering January 16, 2013 -3- Project No. 544-13010 13-01-018 The seismic design category for a structure may be determined in accordance with Section 1613 of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used -to estimate design seismic loading for the proposed structures. The 2010 CBC Seismic Design Parameters are summarized below. Occupancy Category (Table 1604.5): II - Site Class (Table 1613.5.2): D Ss (Figure 1613.5.1): 1.508 A , S1(Figure 1613.5.1): 0.608 Fa (Table 1613.5.3(1)):1.0 Fv (Table 1613.5.3(2)): 1.5 Sins (Equation 16-36 (Fa X Ssl):1.50g Smi (Equation 16-37 (Fv X Si)): 0.908 SDS (Equation 16-38 (2/3 X Smsl):1.00g SDI (Equation 16-39 (2/3 X Smil): 0.60g Seismic Design Category: D In addition, we have sampled the surface soil on the subject lot to determine the soluble sulfate content as it relates to selecting appropriate concrete mix designs. Testing indicates that the site soil is potentially corrosive with respect to concrete. The testing indicated soluble sulfate content of "3000 ppm (0.300 percent) that corresponds with the. "severe" exposure category in accordance with ACI 318-08,'Table 3. . In accordance with ACI 318=08; special sulfate related concrete mix designs will be required. Structural concrete in contact with the soil should include Type V cement, a minimum compressive strength of 4500 psi and a maximum water cement ratio of 0.45'. If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING ,. BRETT L. `F DERSON G� y Brett L. onZ CM No. q- z Ui Exp 9/30/14. . Principal Engineer ccCIVIL ENGINEERIPIG 4 SER/gvm Copies: 4/Albers Construction Company, Inc: Sladden Engineering n Sladden Engineering 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 45090 Golf Center Pkwy, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 Date: January 17, 2013 Account No.: 544-13010 Customer: Albers Construction Co., Inc Location: The Hideaway, 80-270 Via Capri, La Quinta Analytical Report Sulfate Series Soluble Sulfates Soluble Chloride per CA 417 per CA 422 PPM PPM 3000 1050 Sulfate 544-13010 011713 (2).doc TABLE 19-A-3—REQUIREMENTS.FOR.CONCRETE EXPOSED TO SULFATE=CONTAININr -cnl.l rnnnio tit' MIN MUM.' MAXIMUM NORMAL' -WEIGHT AND . MaxlmurnVater- Cementltlous Materia IV Ratio, -by'.. Wagh4•:-, Normal -Vel' Co9create Concreto WATER-CEMENtMOUSIGHTEIGHT,: SULFATE EXPOSURE WATER- SOLUBLE SULFATE (SOi),IN SOII� PERCENTAGE BY WEIGHT MATERIALS- RATIO; BY. ;' AGGREGATE.CONCRETE, EXPOSURE CONDITION WEIGHT, NORMAL -WEIGHT AGGREGATE CONCRETE psi. Concrete intended to have low permeability when x O.DIM69.lor MPa exposed to water - 0.50 0.10-0.20 Concrete exposed to freezing and thawing in a moist 1I, IP(MS), IS (MS) 4,000 condition or to deicing chemicals 4 000 Scverc For corrosion protection for reinforced cOnc,,tc 0.45 4,500 exposed to chlorides from deicing chemicals, salts or 4.500 brackish water, orsprayfrom thesc'sources Over 2.00 Over 10,000 V plus pozzolan3 0.40 5,000 TABLE 19-A-3—REQUIREMENTS.FOR.CONCRETE EXPOSED TO SULFATE=CONTAININr -cnl.l rnnnio tit' NORMAL -WEIGHT AGGREGATE LIGHTWEIGHT AGGREGATE .CONCRETE MaxlmurnVater- Cementltlous Materia IV Ratio, -by'.. Wagh4•:-, Normal -Vel' Co9create Concreto !^,'Normal- 'Weight—and . ,Ltghtwelght' ' 'A99*ote, . Concrete,: PO SULFATE EXPOSURE WATER- SOLUBLE SULFATE (SOi),IN SOII� PERCENTAGE BY WEIGHT SULFATE (S0�) IN. WATER, ppm' CEMENT TYPE x t?•00689'IorMPe. Negligible 0.00-0.10 0-150 M6derate2. 0.10-0.20 150-1,500 1I, IP(MS), IS (MS) 0.50. 4 000 Scverc 0.20-2.00 450040,000 V 0.45 4.500 Very severe Over 2.00 Over 10,000 V plus pozzolan3 0.45 4;500 IA lower watcr-c omen sous materials rano or higher strength may be required for low permeability orfor against corrosion of embedded items or freezing and thawing (rabic 19-A-2). protection ZSeawater 3Pozzolan that has been determined by test or service record to i taiiiing Typc V cement. „ mprove sulfate resistance when used in concrete con- , 2-264 'Electronically Piled by Tim Scott and Authenticated at CalCERTS.com - 1/23/2013 -Electronically Signed at CalCERTS.com by Bill Albers (Albers Construction Co., Inc.) 1%23/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1R Project Name : • - - Mr 8 MIS Richard Albers Building Type 1® Single Family fJ Addition AloneDate O Multi Family .13Existing+ Addition/Alteration 1112312013 Project Address 80-270 Via Capri The Hideaway La Quint California Energy Gimate Zone CA Climate Zone 15 Total Cond. Floor Area 5,000 Addition n/a #of Stories, 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No - HERS Measures -- If Yes, A CF -4R must lie provided per Part 2 of 50of this'form. El Yes .' ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area • Special Construction Type, Cavity Features (see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,976 Radiant Barrier New Well Wood Framed R-21 3,899 New Slab Unheated Slab•on-Grade 3' P 'm = 41 New Door Opaque Door N nQUIN-6ANew.. SAFETY DEP - o ON CM rt OF Lq QUINTA FENESTRATION' A - 2 �3 BY RfrDEVELOPMENT Orientation Area f i i Wins Shades Status Skylight 4.0 `' 0.550 0.67 none none None New Lek (W) 128.0 %- 0.530, .0:46,none„y , ,,,,none #� _ -.- .Bug.ScreenM New Skylight j , 16.00'S50t`n- 0.67 nn"nezr�, none, rNone!�. New Rear (N) ` F ,� 4`00 0'., Jf -j 0.530 0 46 b none' knone r Bug Screen M� Rear, (NE) - := X",80 0„���,+++��4 0.530 0.46 ,none .., none t Bug -Scree> X1 yNew r1 -t Front (S)i;, 170.0 f es, X 0.530 0.46 non ,s� none , ; Bug Screen lg#7MWfNew Left (NW)80.0 ; 0.530. ., 0.46 none *” ^ '� none `' Bug Screen ""' New Skylight_ �. "�, 4.0 1;0.550* 0.67 none none None New Right (E), - ;* 12.0 '0.530 0.46 none none Bug Screen New Front (Si4l ,. 'X68.0 . .':0.530 0.46 none none Bug Screen New HVAC SYSTEMS Ot . Heatin • Min.'Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.3 SEER Setback • New ` 2 Central Furnace 80%AFUE Split Air Conditioner ' 16.0 SEER Setback New 1 Central Furnace 80%AFUE Split Air Conditioner 16.3 SEER r Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value` Status HVAC 1 Ducted Ducted Attic, CeiBng Ins, vented 4.2 New HVAC 2 8 3 , Ducted Ducted Attic, Ceiling Ins, vented - 4.2 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Sma# Gas 50 0.61 No Pipe Insulation New Ene%yPro 5.1 by EnerpySoft User Number. 6712 RunCode: 2013-01-23T08:31:47 ID: Page 1 of 7 Reg: 213-N0004580A-000000000-0000" Registration Date/Time: 2013/01/23 11:33:01 HERS Providei: Ca10ERTS,1 Inc y Electronically Filed by Tim Scott and Authenticated at CalCERTS.ccm - 1/23/2013 Electronically Signed at CalCERTS.aom by Bill Albers (Albers Construction'Co., Inc.) 1/23/2013 PERFORMANCE CERTIFICATE: Residential • ' , Part 1 of 5 CF -1 R Project Name MT &Mrs Richard Albers Building Type ® Single. Family ❑ Addition Alone_Date ❑ Multi Family E3Existing+ Additio/Alteration 1/23/2013 Project Address 80-270 Via Capri The Hideaway La Quint California Energy Gimate Zone CA Climate Zone 15 Total Cond. Floor Area 5, 000 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes, ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 •of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. - INSULATION Area Special Construction Type Cavity Features see Part 2'of 5 Status ti .. . FENESTRATION . ' `: U. Exterior Orientation Area fFactor SHGC Overhang Sidefins 'Shades Statu-s 1 /��� r ... •q �} ��+y�•� j{/�' (,� .�: ,...,,.,,-ka,/,-+ +yyr .s, J{ die '}■� [y(�r' -,a S,�+A% ''•-4 ,..'� f � '/r!�'il���f `. i - 1-@y:� ..�� � f.. -14>, � •r..�'•�.�.e':j i �`'. ¢ y s� py.�,� ,� y�■ n. �� [ ��i�- c'3'•a'%��d[.: ,"Q:'.",8'3..Y.. � f: �..d.'• ,� � �•. } � �—.—._y,���'./.-.�.{r.,,..�:+ii�„—,•cy,..+�,,ti . iI� jjN 4 t,`- � t�"Y���11�'� � /F %!�� � ��Y �p� � J ✓,�.`.. .:f�" Ytf Y h. /'S.`-'�'. �. /.'..� �r�i*��1,1�r�'.l ,¢�:},,� }./ i-��',,.Sµ - 'r � ,�I'.""",�?FiS4+, 'yv, � \+ �~-� - .:R. 2a � ���t~2'. t N'�.'yT" i `T•".-� _,, -. . ,._ I\J HVAC SYSTEMS Ot . Heating.' Min. Eff- Cooling Min. Eff Thermostat Status 1 Cer&al Furnace 180% AFUE Split Air Conditioner 14.5 SEER , ' Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted' Ducted Attic, Ceiling Ins, vented' 4.2 New WATER HEATING , Ot . Type Gallons Min. Eff Distribution Status Energjfto 5.1 by EnergySoft User Number. 6712 RunCode: 2013-01-23708:31:47 /D: • Page 2 of 7 Reg: 213-N0004580A-000000000-0000, Registration Date/Time: 2013/01/23 11:33:01 'HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/23/2013 + .Electronically Signed at CalCERTS.com by Bill Albers (Albers -Construction Co., Inc.) 1/23/2013 k Reg: 2137N00045BOA-000000000-0000 Registration Date/Time: 2013/01/23 11:33:01 HERS Provider: Ca10ERTS, Inc ` PERFORMANCE' CERTIFICATE: Residential Part2 of 5 CF -1R Project Name Building Type ® Single Family ❑ Addition Alone Date Mr & Mrs Richard Albers ❑ Multi Family • ❑ Existing+ Addition/Alteration ,1/23/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential A ndix RA3.3 must be met HIGH MASS Design - Verify Thermal Mass: 646.0 ftp Covered Slab Floor, 3.500" thick at Bedroom 2 & 3 HIGH MASS Design -Verify Thermal Mass: 160.0 fl= Exposed Slab Floor, 3.500" thick at Bedroom 2 & 3 The HVAC System HVAC 2 & 3 must serve only Living Areas. The non-dosable area between zones cannot exceed 40 sf and each zone must have a separate thermostat In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met HIGH MASS Design - Verify Thermal Mass: 630.0 R= Covered Slab Floor, 3.500" thick at Family Great Kitchen HiGH MASS Design - Verify Thermal Mass: 1,724.0 fl= Exposed Slab Floor, 3.500" thick at Family Great Kitchen - The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fen watt draw requirements in Residential Appendix RA3.3 must be met HIGH MASS Design - Verify Thermal Mass: 949.0 R' Covered Slab Floor, 3.500" thick at Master 3 . HIGH MASS Design - Verify Thermal Mass: 462.0 IV Exposed Slab Floor, 3.500" thick at Master The HVAC System HVAC 5 must serve onty Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se ara'te thermostat. In'addition the air flow requirements and fan watt draw requirements in Residential A ndix RA3.3 must be met. . HIGH MASS Design - Verify Thermal Mass: 332.0 IV Covered Slab Floor, 3.500" thick at Cas" HIGH MASS iiigrn"Ver(ify Thermal Mass- 1000.0 & Ezpo�s"e_d-Slab-Flda 3.500 thick at�Casita . /D.d OF The Roof R-38 Roof(R 38 2x14 16) includes credit for a Radiant Barrier that is''Contindous meeting eligibility and installation criteria as specified in , Residential Appendix RA4:2 2. HERS RE0UIR.ED`N.EAIFICATION' Zt4r���-h6�flris ,+,n����Items _��..� �• t e� *,cam . `.4 ., .��- ..�i ---. in;tFiis1section require•field,testingand/or verificationty arcertified HERS Tpector must receive a com leied'CF-4R form for each of the measures listed below.for final to be iven. - The Cooling System York C2F030 TMBLX060Al2MP1 i includes credit for a 13.3 EER Condenser. A certified HERS rater must field verify the y installation the correct Condenser. l of The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria' The Cooling System York CZF060 TM8LX100Al2MPI I includes credit for a 13.3 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. s The Cooling System York CZF048 TMBLX100C20MP11 includes credit for a 13.5 EER Condenser. A certified HERS rater must field_ verify the installation of the correct Condenser. ' The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS Field verification and diagnostic testing is required to verify that duct leakage meets the specified kriteria. ' The Cooling System York YCJD18 TMBLX06OAl2MP11 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. ± The HVAC System HVAC 5 incorporates HERS Verified Refigerant Charge or a Charge Indicator Display. , The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified kriteria. F En o 5.1 b Ene oft User Number. 6712 RunCode: 2013-01-23 70 8:31:47 /D: Pa e 3 of 7 ,Electronically Filed by Tim'Scott and Authenticated at CalCERTS.com - 1/23/2013 Electronically Siqned at Ca10ERTS.com by Bill Albers (Albers Construction Co., Inc.) 1/23/2013 Reg: 213-N0004580A-000000000-0000 Registration Date/Time: 2013/01/23 11:33:01 HERS Provider: Ca10ERTS, Inc . PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family [3Addition Alone Date . Mr & Mrs Richard Albers [3Multi Family ❑ Existing+ Addition/Alteration 1112312013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/fe- r '' . . Space Heating 3.70 4.60 -0.91 Space Cooling 55.53 45.99 9.53 Fans 11.22' 14.93 -3.71 Domestic Hot Water 7.30 7.07 0.23 Pumps 0.00 0.00 0.00 Totals 77.74 '72.59 5.15 , Percent Better Than Standard:,, 6.6% ' BUILDING COMPLIES. - HERS VERIFICATION REQUIRED .Fenestration . Building Front Orientation:. (S) 180 deg Ext. Walls/Roof Wall Area Area' Number of Dwelling Units: 1.00 (S) 1,292 238 Fuel Available at Site: Natural Gas (W 1,258 208 Raised Floor Area: 0 (N) 1,259• 480 Slab on Grade Area: 5,003 (E) 1,052 `• 12 Average Ceiling Height: , , ,. .11.9 Roof - 5,000 a 24 Fenestration Average U -Factor: 0.53 TOTAL: 962 Average SHGC:" 0.46 t . Fenestration/CFA Ratio: 19.2% - REMARKS— '- The. Hideaway Lot # 54 & 55 - �,y.' Cy,t ..... .a.::,i' �7 s %• r•a qty,' <` •4.+h /rv' Yhi�' k(r i,A "+!'• Y H qF : Il'-weH T •�.• F V'.� Y, -F .� s ' �• .. yli dy STATEMENT'OF COMPLIANCE - This certificate of compliance' lists' the building features and specifications needed - tc comply with Title 24,'Partsy1.,ttie Administrative Regulations and Part 6 the ' Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation.is accurate and complete. < < Documentation Author Company Scott Design and Title 24, Inc, 1/23/2013 Address ' '77-065 Michigan Drive Name Tim Scott ; City/state/Zip Palm'Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and_recognizes,that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing•require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) C, Company , Residential Concepts Address 80-270 Via Capri The Hideaway Name Jerry W. Sherman •W�, 2 ' 13 .z • City/Stateop La Quints, CA 92253 Phone (760) 342-1709 Si - License# Date Ene ro 5.16 Ene oft User Number. 6712 RunCode: 2013 01-23708:31:47 ID: Pace 4 of7 Reg: 213-N0004580A-000000000-0000 Registration Date/Time: 2013/01/23 11:33:01 HERS Provider: Ca10ERTS, Inc . PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family [3Addition Alone Date . Mr & Mrs Richard Albers [3Multi Family ❑ Existing+ Addition/Alteration 1112312013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/fe- r '' . . Space Heating 3.70 4.60 -0.91 Space Cooling 55.53 45.99 9.53 Fans 11.22' 14.93 -3.71 Domestic Hot Water 7.30 7.07 0.23 Pumps 0.00 0.00 0.00 Totals 77.74 '72.59 5.15 , Percent Better Than Standard:,, 6.6% ' BUILDING COMPLIES. - HERS VERIFICATION REQUIRED .Fenestration . Building Front Orientation:. (S) 180 deg Ext. Walls/Roof Wall Area Area' Number of Dwelling Units: 1.00 (S) 1,292 238 Fuel Available at Site: Natural Gas (W 1,258 208 Raised Floor Area: 0 (N) 1,259• 480 Slab on Grade Area: 5,003 (E) 1,052 `• 12 Average Ceiling Height: , , ,. .11.9 Roof - 5,000 a 24 Fenestration Average U -Factor: 0.53 TOTAL: 962 Average SHGC:" 0.46 t . Fenestration/CFA Ratio: 19.2% - REMARKS— '- The. Hideaway Lot # 54 & 55 - �,y.' Cy,t ..... .a.::,i' �7 s %• r•a qty,' <` •4.+h /rv' Yhi�' k(r i,A "+!'• Y H qF : Il'-weH T •�.• F V'.� Y, -F .� s ' �• .. yli dy STATEMENT'OF COMPLIANCE - This certificate of compliance' lists' the building features and specifications needed - tc comply with Title 24,'Partsy1.,ttie Administrative Regulations and Part 6 the ' Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation.is accurate and complete. < < Documentation Author Company Scott Design and Title 24, Inc, 1/23/2013 Address ' '77-065 Michigan Drive Name Tim Scott ; City/state/Zip Palm'Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and_recognizes,that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing•require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) C, Company , Residential Concepts Address 80-270 Via Capri The Hideaway Name Jerry W. Sherman •W�, 2 ' 13 .z • City/Stateop La Quints, CA 92253 Phone (760) 342-1709 Si - License# Date Ene ro 5.16 Ene oft User Number. 6712 RunCode: 2013 01-23708:31:47 ID: Pace Electronically Piled by Tim Scott and Authenticated at Ca10ERTS.com - 1/23/2013 Project Name Mr & Mrs Richard Albers Electronically Signed at CalCERTS.com by Bill Albers (Albers Construction Co., Inc.) 1/23/2013 OPAQUE SURFACE DETAILS " CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 4 CF -1R Project Name Mr & Mrs Richard Albers Building Type O Single Family ❑ Addition Alone ❑Multi Family Existing+ AdditioNAlteration Date 1112312013 OPAQUE SURFACE DETAILS " Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 802 0.026 R-38 0 20 New 4.2.1-A9 Bedroom 2 & 3 Wall 55 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 336 0.069 R-21 180 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 348 0.069.R-21 270 90 New 4.3.1-A6 Bedroom 2 & 3 Slab " 646 0.730 None 0 180 New 4.4.7-A 1 Bedroom 2 & 3 Slab 160 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 & 3 Roof 2,338 0.026 R-38 0 20 New 4.2.1-A9 Fami Great Kitchen Wall 482 ..0.069 R-21 0 90 New 4.3.1-A6 Family Great Kitchen Wall 102 0.069 R-21 45 90 New 4.3.1-A6 Family Great Kitchen Well _ 196 0.069.R-21 90 90 New 4.3.1-A6 Family Great Kitchen Wall 414 0.069 R-21 180 90 New 4.3.1-A6 Family Great Kitchen Door 24 0.500 None 180 90 New 4.5.1-A4 Family Great Kitchen Wall 490 0.069 R-21 270 - 90 New 4.3.1-A6 Family Great Kitchen Wall 102 0.069 R-21 315 90 New 4.3.1-A6 Family Great Kitchen Slab . -630 0.730 None 0 180 New 4.4.7-A1[Family Great Kitchen - Slab 1,724 0.730 None 0 180 New 4.4.7-A1 JFamily Great Kitchen FENESTRATION SURFACE.DETAILS ID Type Area r LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Skylight 4.0 0.550 Default 0.67 Default 0 New Double Non Metal Clear Bedroom 2 & 3 2. Window 30.0 0.530 NFRC 0.46 NFRC 270 New Dual Metal Tint Bedroom 2 & 3 �3 Window-, -. x'48.0 0.530 NFRC 0.46 NFRC 270 New Dual Metal Tint Bedroom 2 & 3 4, Skylight 16.0 0.550 Default 0.67 Default -0 New Double Non Metal Clear Family Great Kitchen 5 Window - ,-120.0 0.530 NFRC;: _ 0.46 NFRC, 0 New--- Dual Metal Tint Family Great Kitchen 6 Window�sr : 'k120.0 0.530 NFRC o X0.46^ ,NFRC ('O New N Dual MetaLTinf4 ,Af,t �t "= " %, Family Great Kitchen 7 Window:." ' 36.0 '0.530 NFRC l ' V 0:46 (NFRC i a' : .', 0 Newl' ,.e',, } Dual Metal Tint --ss ., .. y� }* Family Great Kitchen 14,-45 8 Window' 80.0- Z 0.530, NFRC,l °"' 0.46 NFRC 1- New , e+'� -Dual Metal Tint - ` \: Family Great Kitchen 9 Window 2.4.0 /10.530 NFRC. ,t 0.46 NFRC', '' #,180 New ;� Dual Metal;Tint Family, Gres t Kitchen �a 10 Windaw ,4 At 6.0' i 0.530, NFRC ' * 0.46' N ,FRC ,8 X180 'New: -J Dual Metal Tint R. _. ` 1 Family Great Kitchen - -> 11 - WindowoK 060.0 ..0.530 NFRC. '' r.w0:46 NFRC'e-?180 New V Dual Metal Tint CC-, Family GieatKitchen 12' Window.: : :80.0 "-0.530 NFRC 0.46 NFRC !r 180 New Dual Metal _Tint: I -e; * "' Family Great Kitchen 13 Window 80.0 0.530 NFRC 0.46 NFRC 1.315 New Dual Metal Tint Family Great Kitchen .14 - Skylight- -1,.4.0 0.550 Default 0.67 Default 0 New Double Non Metal Clear Master 15 , Window. . 120.0 0.530 NFRC 0.46 NFRC 0 New Dual Metal Tint Master 16 Window ' 4.0 0.530 NFRC 0.46 NFRC 0 New Dual Metal Tint Mester (1) U -Factor Type: '116-A = Default Table from Standards, NFRC =Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin - Right Fin ID Exterior Shade Type SHGC Hot Wd Len H LExt RExt Dist Len Hat Dist Len Hq t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Norte 1.00 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 None 1.00 15 IBug Screen 0.76 16 IBug Screen 0.76 s. EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-01-23708:31:47 /D: Page 5 of 7, Reg: 213-N0004580A-000000000-0000• Registration Date/Time: 2013/01/23 11:33:01 HERS Provider: Ca10ERTS, Inc U A Electronically Filed by Tim Scott and Authenticated at Ca10ERT5`.com - 1/23/2013 Electronically Signed at'Ca10ERTS.com by•Bill Albers (Albers Construction Co., Inc.) 1/23/2013 CERTIFICATE'OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Mr & Mrs Richard Albers Building Type ' m Single Family O Addition Alone 17 Multifamily ❑ Existing+ Addition/Alteration Date 1/2312013 OPAQUE SURFACE DETAILS Surface U- Insulation - Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments . Roof 1,404 0.026 R-38 0 '20 New 4.2.1-A9 Master Wall 140 0.069 R-21 0 90 New 4.3.1-A6 Master Wall 608 ' 0.069 R-21 90 90 New 4.3.1-A6 - Master well 88 0.069 R-21 3 180 90 New 4.3.1-A6 Master Slab 949 0.730 None 0 -180 New 4.4.7-A 1 Master Slab 462 0.730 None 0 180 New 4.4.7-A 1 Master Roof 432 0.026 R-38 _ 0 20 New '' 4.2.1-A9 Casits Wall • 236 • 0.069 R-21 t 90 90 New + 4.3.1-A6 .. Casita Wall 100 0.069 R-21 180 90 New 4.3.1-A6 Casita Wall 92 0.069 R-21 225 90 New , 4.3.1-A6 Casfte Wall 110 0.069 R-21 J 270 90 New 4.3.1-A6 Casita Slab 332 0.730 None 0 180 New 4.4.7-A 1 Casks Slab 100 0.730 None 0 180 New 4.4.7-A 1 Casfta FENESTRATION SURFACE DETAILS ID Type Area - /U -Factor _ SHGC. Azm Status Glazing Type Location/Comments 17. Window 4.0 0.530 NFRC 0.46 NFRC 90 New Dual Metal Tint Master F 18 _ Window 4.0 0.530 NFRC 0.46 NFRC 90 New Dual Metal Tint Master 19 Window' •• -.• 4.0 0.530 NFRC 0.46 NFRC 90 New Dual Metal Tint CesBa 20 Window. 68.0 0.530 NFRC 0.46 NFRC .. 225 New Dual Metal Tint Casita 21%. Window. ..50.0 0.530 NFRC: _-0. 46, NFRC ,__, -` 27_0 New-_ Dual Metel_Tint Casita ,�+f"r�` 'a`'4��"x '•t-•-��i....'� G�`�r. �.{:r 7 f�*•�.'Sd`:l'>�Ft� .�4 ¢:i_/„�ee�.�.a-�lF..� 3�' LI a&t.. �F .F.• 7 ,(: xj I J.„ �.�:.i 4 }.. � •�' �i' � .'�.,-'"� i'..+�1,-+,..�y'.a�4 � • M'._'YJ ,... .s.,'iyf�?:. a i It Ati � � {.•�� --��.. �'i. '4 sly;._. � ��- ... �..r'� �vw. ,.'. 4r' ,�i. '9i.+�+• :"4'-�rR•-}"." ;�:.s�Af'1 �'7r�Ta'. t�� �A'_-µms !' 4�n.r ..1•':6+4.?.- ..ry` �.ls'. ��uu`'-yY1!11 ••IY"S. ]G.. i�Y.n .. , ! ..Hr� ». s An (1) U -Factor Type: ,116-A =_ Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 =' Defauft Table from Standards NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hanq Left Fin Right Fin ID Exterior Shade Type' SHGC Hat Wd Len Hot LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 f, 20 Bug Screen 0.76 21 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode:2013-01-23T08:31:47 /D: Page 6 of7 Reg: 213-N000458OA-000000000-0000 Registration-Date/Time: 2013/01/23 11:33:01 HERS Provider: Ca10ERTS, Inc n ,-Electronically jiled by Tim. Scott and Authenticated at Ca10ERTS.com --1/23/2013 Electronically Signed at CalCERTS.com by Bill Albers (Albers Construction Co., Inc.) 1/23/2013 CERTIFICATE'OF COMPLIANCE: Residential Part 5 of 5 CF -1R Project Name ti Mr & Mrs Richard Albers Building Type m Single Family ❑ Addition Alone ❑ Multi Family , ❑ Existing+ Addition/Alteration Date •1/23%2013 BUILDING ZONE INFORMATION Floor Area System Name Zone Name New Existing Altered • Removed Volume Year Built HVAC 1 Bedroom 2 & 3 806 8,060 HVAC 2 & 3 Family Great Kitchen 2,354 32,956 HVAC 4 Master 1,408 14,080 HVAC 5 Casita 432 4,320 it Totals 5,000 0 01 0 HVAC SYSTEMS 1::'' ' System Name -,Heating Type Min. Eff. Cooling Type Min, Eff. Thermostat Type Status HVAC 1 "' y,+ 1 Central Fumace 80% AFUE Split Air Conditioner 16.3 SEER Setback New HVAC 2 & 3 2 } Central Fumace 80% AFUE Split Air Conditioner 16.0 SEER Setback 4 - 1 CentrelF-urnace',-4 -80%,AFUE S lif Air Conditioner =16.3_SEER, Setback:. 80°�AFUE S'IitrAirConditione..J 14.5 SEER Setbacks" 4NewHVAC -411 J HVAC DISTRIBUTION`S ja' :.y ""_.� + 4',. u,r�F• ,�,, •; _ -�.� �� , ..�..• ... � .'�. ,.-�+�.T .� ' � "��tDuct�lL?li_�.`•Ducts?''tvti %r ,��.t`• {.<W✓.�S.:g+. L� fir/ �• •�- '� System Name Heatin • . Coolinw_. Duct Location1 F R -Value Tested? Status HVAC 1 _ .� • Ducted Ducted Attic, Ceiling Ins, vented 4.2 m New HVAC2'9'3 N, Ducted ... Ducted Attic, Ceiling Ins, vented 4.2 m New HVAC 4 ` ;: ` i. Ducl'ed.'' Ducted Attic, Ceiling Ins, vented 4.2 M New HVAC 5 *\I Ducted '' Ducted Attic, Ceiling Ins, vented 1 4.21 lNew WATER HEATING SYSTEMS - S stem Name Tvoe Distribution' Rated Input (Btuh) Tank Cap. (gal Energy Standby 'Factor Loss or or RE Pilot Ext. Tank Insul. R- Value ' Status G50T236 American Stend 1 Small Gas No Pipe Insulation 40,000 50 0.61 We We New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING ControlHP Hot Water Piping Length ft , c o a — System Name Pipe Len th Pipe Diameter- Insul. Thick. 'Plenum Outside Buried 13❑ EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-01-23T08:31:47 Q Page 7 of 7 Reg: 213-N0004580A-000000000-0000 Registration Date/Time: 2013/01/23 11:33:01. HERS Provider: Ca10ERTS, Inc