Loading...
BRES2014-1153LA QUINTA, CALIFORNIA 92253 . f) Application Number: BRES2014-1153 Property Address: 80325 VIA CAPRI APN: 777100052 Application Description: 6,931SF DWELLING Property Zoning: Z _n Application Valuation: $730,199.50 Applicant: FEDDERLY & ASSOCIATES 38-747 NOPALES ROAD PALM DESERT, CA 92211 ceit�p 44 Q" COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 {commencing with Section 7000} of Divisio of the Business and Professions Code, and my License is in full force and effect. License Cla s: License No.: C28860 Date ` Contract* % Gi� S� ✓1�t Ile It OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Owner: ALAN FLEENOR 80100 VIA PESSARO VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/27/2015 LA QUINTA, CA 0 0 �- a: c Z _n _n o cu Contractor: o ILS MONARCH HOMES 49950 JEFFERSON STREEI #130 ry LA QUINTA, CA 92264 m n cv o (951)634-6381 Llc. No.: C28860 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compe ation, as provided for by Section 3700 of the Labor Code, for the performance of the rk-for which this permit is issued. -1-have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ .Policy Number:' I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manne as to become subject to the workers' compensation laws of California; and agree t ould become subject to the workers' compensation provisions of Sect' n 37 o e Labor Code, I shall forthwith comply wijh,those provisions. ill i S s WARNING: FAILURE TO SECURE WORKERS LOA4P£NSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees.to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees.for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that thewove information is correct. I agree to comply with all city and county ordinances ands relating to building construction, and hereby authorize representatives of thi i t nter upon the above - mention d property for inspection purposes. l Dat, e n J Signature (Applicant or Age t): �i✓ r .� FINANCIAL INFORMATION -DESCRIPTION ACCOUNT :. QTY '. AMOUNT PAID PAID DATE ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $1,325.50 $1,325.50 2/27/15 PAID BY . •METHOD RECEIPT # ; . CHECK_# CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH Total Paid forART IN PUBLIC PLACES - AIPP: $1,325.50 $1,325.50 DESCRIPTION ACCOUNT' QTY, " AMOUNT, PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $30.00 $30.00 2/27/15 PAID BY METHOD , . RECEIPT # : CHECK # _ CLTD BY, ALAN FLEENOR CHECK R3834 1074 SKH Total Paid forBUILDING STANDARDS ADMINISTRATION BSA: $30.00 $30.00 DESCRIPTION � ACCOUNT QTY,:: . AMOUNT6 PAID PAID DATE DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 2/27/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - COMMUNITY CENTERS 254-0000-43200 0. $129.00 $129.00 2/27/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY ALAN FLEENOR / CHECK R3834 1074 SKH DESCRIPTION w 'ACCOUNT QTY AMOUNT PAID PAID DATE DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 2/27/15 PAID BY METHOD. RECEIPT ,# CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION :, ACCOUNT QTY,. • AMOUNT• PAID , !,PAID DATE DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 2/27/15 PAID BY .,METHOD RECEIPT# CHECK # ' CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT. QTY AMOUNT PAID PAID DATE DIF - PARK MAINTENANCE 2S6-0000-43200 0 $40.00 $40.00 2/27/15 PAID BY METHOD RECEIPT # `< CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT"QTY AMOUNT PAID PAID DATE. DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 2/27/15 PAID BY METHOD RECEIPT # ' CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $116.00 2/27/15 PAID BY METHOD RECEIPT # " CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF -TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 2/27/15 r . PAID BY METHOD RECEIPT # CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 I DESCRIPTION . ACCOUNT QTY : °.; AMOUNT' PAID PAID DATE TEMP POWER SERVICE 101-0000-42403 0 $24.17 $24.17 2/27/15 PAID BY f, METHOD ,.,° RECEIPT # i r e� a CHECK # t CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH ' DESCRIPTION '' ACCOUNT QTY AMOUNT PAID PAID DATE TEMP POWER SERVICE PC 101-0000-42403 0 $16.92 $16.92 2/27/15 + PAID BY METHOD : RECEIPT•# w CHECK # ` " . CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH Total Paid for ELECTRICAL: $41.09 $41.09 DESCRIPTION ,` :ACCOUNT. QTY AMOUNT,, ° ° PAID ,PAID. DATE RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $98.64 $98.64 2/27/15 r PAID BY METHOD RECEIPT # CHECK # CLTD BY ALAN FLEENOR CHECK R3834 • 1074 SKH .'-DESCRIPTION ACCOUNT QTY AMOUNT PAID' PAID DATE; RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $40.64 $40.64 2/27/15 ' r ' PAID BY METHOD RECEIPT # CHECK # t 1CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT QTY "' AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 2/27/15 PAID BY, METHOD ., RECEIPT # . ° CHECK # , ,. CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT QTY, AMOUNT _ PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47.86 2/27/15 PAID BY �. .: METHOD v RECEIPT # CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH Total Paid forELECTRICAL - NEW CONSTRUCTION: $332.17 $332.17 DESCRIPTION h ,' ACCOUNT: QTY AMOUNT PAID PAID DATE RESIDENTIAL FINISH GRADING PC 101-0000-42600 0 $143.00 $143.00 2/27/15 PAID BY , METHOD RECEIPT # CHECK # CLTD BY ALAN FLEENOR CHECK R3834 . 1074 SKH Total Paid forGRADING: $143.00 $143.00 DESCRIPTION ACCOUNT QTY: " AMOUNT, " PAID PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $253.82 $253.82 2/27/15 - PAID BY METHOD RECEIPT # CHECK # CLTD BYw' ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ; . SACCOUNT` QTY1 AMOUNT PAID --PAI . D DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $169.19 $169.19 2/27/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION x ACCOUNT QTY E AMOUNT a PAID .' PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 2/27/15 PAID BY METHOD RECEIPT # CHECK #., r CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH a DESCRIPTION `- r ACCOUNT " 1 QTY ° AMOUNT,; • PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $4.83 2/27/15' PAID BY METHOD RECEIPT # �' CHECK # `, ' , CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ! ACCOUNT:.: QTY AMOUNT .; PAID ` PAID DATE: FURNACE 101-0000-42402 0 $253.82 $253.82 2/27/15 PAID BY METHOD "; :RECEIPT # . CHECK # ": CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION , ACCOUNT _ QTY , ° AMOUNT •PAID`, PAID DATE FURNACE PC 101-0000-42600 0 $169.19 $169.19 2/27/15 PAID BY `' METHOD,' , RECEIPT # CHECK # c' CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT QTY AMOUNT- PAID PAID DATE VENT FAN 101-0000-42402 0 $169.26 $169.26 2/27/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY ALAN'FLEENOR CHECK R3834 1074 SKH „ DESCRIPTION ACCOUNT QTY, AMOUNT PAID ` PAID DATE VENT FAN PC 101-0000-42600 0 $67.62 $67.62 2/27/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH Total Paid forMECHANICAL: $1,099.82 $1,099.82 DESCRIPTION ACCOUNTQTY AMOUNT - PAID'; a PAID DATE NEW CONSTRUCTION PERMIT 101-0000-42400 0 $878.93 $878.93 2/27/15 'r PAID BY ;fi METHOD u RECEIPT # CHECK #'CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH Total Paid for NEW CONSTRUCTION PERMIT: $878.93 $878.93 -DESCRIPTION. ACCOUNT I QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $512.44 $512.44 2/27/15 PAID BY",. METHOD - RECEIPT # CHECK # ," c CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH • DESCRIPTION ACCOUNT. QTY AMOUNT' PAID PAID DATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,400.00 $1,400.00 10/28/14 F, PAID BY METHOD,' 4 % RECEIPT # . RE CHECK # " CLTD BY FEDDERLY & ASSSOC. CHECK R2511 098052 PJU Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,912.44 $1,912.44 DESCRIPTION ACCOUNT. QTY? AMOUNT , _ = PAID PAID DATE BACKFLOW DEVICE 101-0000-42401 0 $12.09 $12.09 2/27/15 PAID BY. i METHOD RECEIPT # ° CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT :. QTY AMOUNT ' ; : _ PAID PAID DATE BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $4.83 2/27/15 PAID BY :j METHOD RECEIPT # CHECK # ' CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH ' DESCRIPTION, ' ' ACCOUNT.. QTY , AMOUNT ,.: ,..:PAID � PAID D _. ATE. BUILDING SEWER 101-0000-42401 0 $12.09 $12.09 2/27/15 PAIDBYMETHOD " ,:RECEIPT # x CHECK #, CLTD BY: ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT. QTY AMOUNT PAID PAID DATE BUILDING SEWER PC 101-0000-42600 0 $12.09 $12.09 .2/27/15 PAID BY METHOD RECEIPT #.:- CHECK # ' CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ipACCOUNT '[ QTY^, -AMOUNTt PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $314.34 $314.34 2/27/15 PAID BY METHOD , RECEIPT # CHECK#1 CLTD BY,. ALAN FLEENOR CHECK R3834 .1074 SKH DESCRIPTION ACCOUNT QTY AMOUNT: ; PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $314.34 $314.34 2/27/15 PAID BY : METHOD `, RECEIPT # CHECK # '= CLTD BY^ ' ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTIONACCOUNT QTY AMOUNT' PAID PAID -DATE: GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $36.26 $36.26 2/27/15 = ` - • PAID BY _ METHOD ,,. . _ , " :RECEIPT # CHECK # <: CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH ` DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID. DATE GAS SYSTEM, S+ OUTLETS PC 101-0000-42600 0 $24.17 $24.17 2/27/15 PAID BY ' METHOD r RECEIPT #. .. s`CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH ;:DESCRIPTION ; ACCOUNT : QTY AMOUNT PAID PAID DATE WATER HEATER/VENT 101-0000-42401 0. $36.27 $36.27 2/27/15 PAID BY METHOD RECEIPT # . CHECK # CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT ' QTY AMOUNT` PAID PAID DATE WATER HEATER/VENT PC 101-0000-42600 0 $21.75 $21.75 2/27/15 PAID BY METHOD, ': '. ;; RECEIPT # CHECK # , CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT QTY _ . AMOUNT' ;' ' PAID PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $12.09 2/27/15 PAID BY * ' METHOD .. RECEIPT # '. .' CHECK$f CLTD BY ALAN FLEENOR CHECK R3834 1074 SKH DESCRIPTION ACCOUNT. QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 U $12.09 $12.09 2/27/15 ;PAID BY,', -a ; €_ .. n 'METHOD RECEIPT # =, CHECK # CLTD BY', ALAN FLEENOR CHECK R3834 1074 SKH Total Paid forPLUMBING FEES: $812.41 $812.41 DESCRIPTION ;: ` 4 ACCOUNT ­'CITY AMOUNT tF c PAID DATE y IPAID SMI - RESIDENTIAL 101-0000-20308 0 $94.93• $94.91 2/27/15 -� METHOD`i RECEIPT # CHECK # r'CLTD BY �• . ;, ALAN FLEENOR CHECK R3834 1074 SKH Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $94.93 $94.93 DESCRIPTION "�y :ACCOUNT ' - QTY AMOUNT ` r' 4' PAID jPAID DATE: L SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $1,837.44 2/27/15 .'.RAIDBY�� �`METHOD� RECEIPT#� ^ '�' CHECK#C LTDBY � �.� n., ALAN FLEENOR CHECK R3834 1074 SKH Total Paid forTUMF - RESIDENTIAL: $1,837.44 $1,837.44' TOTALS: Description: 6,931SF DWELLING Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE Status: APPROVED Applied: 10/28/2014 AOR FAMILY DETACHED - Approved: 1/28/2015 J10 Parcel No: 777100052 Site Address: 80325 VIA CAPRI LA QUINTA,CA 92253 Subdivision: TR 29894-2 AMEND NO 2 Block: Lot: 11 Issued: Lot Sq Ft: 0. Building Sq Ft: 0' Zoning: Finaled: . Valuation: $730,199.50 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: NEW SFD. GARAGE IS A/C 1591 SQ. FT. THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS, DRIVEWAY APPROACH, FIRE -PIT, OR, WATER FEATUREMOME IS FIRE SPRINKLED PER 2013 CRC CODES. 92 ' ' • Applied to Approved Printed: Friday, February 27, 2015 3:15:34 PM 1 of 6 C sysrenns ADDITIONAL CHRONOLOGY CHRONOLOGhTYPE' ,STAFF NAME ACTION DATE, COMPLETION DATE. NOTES PLAN CHECK COMMENTS FROM CONSULTANT JIM JOHNSON 12/1/2014 11/26/2014 STRUC CORRECTIONS REQUIRED RECEIVED PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 1/28/2015 1/28/2015 STRUC APP 1/27/2015 RECEIVED _ PLAN CHECK PICKED UP STEPHANIE KHATAMI 12/1/2014 12/1/2014 PICKED UP BY RICHARD MONTEZ SK PLAN CHECK SUBMITTAL KAY HENSEL 10/28/2014 10/29/2014 RECEIVED PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 2/26/2015 2/26/2015 PM10 SUBMITTED. RECEIVED RESUBMITTAL KAY HENSEL 1/9/2015 1/9/2015 Printed: Friday, February 27, 2015 3:15:34 PM 1 of 6 C sysrenns SENT TO PLAN CHECK KAY HENSEL 10/29/2014 10/29/2014 STRUC TO YOUNG, DUE 11/18 CONSULTANT - SENT TO PLAN CHECK KAY HENSEL 1/9/2015 1/9/2015 STRUC TO YOUNG - DUE 1/23/15 CONSULTANT RECEIPT#- `CHECK #..-' „ METHOD ' '. '>PAID BY CLTD BY ART IN PUBLIC PLACES - 270-0000-43201 0 CALLED FEDDERLY & ASSOCIATES TO INFORM THEM TELEPHONE CALL JIM JOHNSON 12/1/2014 12/1/2014 CHECK ALAN FLEENOR • RESIDENTIAL CORRRECTIONS READY TO PICK UP. CALLED FEDDERLY & ASSOCIATES TO INFORM THEM PLANS Total Paid forART IN PUBLIC PLACES - AIPP: READY TO ISSUE. TELEPHONE CALL JIM JOHNSON 1/28/2015 1/28/2015 BSAS SB1473 FEE 101-0000-20306 FAXED SCHOOL LETTER TO TAMMY AT FEDDERLY & $30.00 $30.00 2/27/15 R3834 ASSOCIATES CHECK ALAN FLEENOR SKH Total Paid for BUILDING STANDARDS ADMINISTRATION $30.00 $30.00 BSA: NAME TYPE 'NAME ' ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT FEDDERLY & ASSOCIATES 38-747 NOPALES ROAD PALM DESERT CA 92211 1074 CHECK ALAN FLEENOR CONTRACTOR MONARCH HOMES 49950 JEFFERSON LA QUINTA CA 92264 $129.00 2/27/15 R3834 1074 CHECK STREET #130 SKH CENTERS OWNER ALAN FLEENOR 80100 VIA PESSARO LA QUINTA CA 0 Printed: Friday, February 27, 2015 3:15:34 PM 2 of 6 cm srsrrMS FINANCIAL INFORMATION DESCRIPTION ACCOUNT., QTY 'AMOUNT PAID PAID DATE RECEIPT#- `CHECK #..-' „ METHOD ' '. '>PAID BY CLTD BY ART IN PUBLIC PLACES - 270-0000-43201 0 $1,325.50 $1,325.50 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH RESIDENTIAL Total Paid forART IN PUBLIC PLACES - AIPP: $1,325.50 $1,325.50 BSAS SB1473 FEE 101-0000-20306 0 $30.00 $30.00 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH Total Paid for BUILDING STANDARDS ADMINISTRATION $30.00 $30.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH DIF - COMMUNITY 254-0000-43200 0 $129.00 $129.00 2/27/15 R3834 1074 CHECK FALAN FLEENOR SKH CENTERS Printed: Friday, February 27, 2015 3:15:34 PM 2 of 6 cm srsrrMS y DESCRIPTION . ANT ACCOUNT QTY AMOUNT- PAID ' PAID DATE RECEIPT # CHECK # METHOD ' PAID BY C LTD, . � - BY DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 2/27/15 -113834 1074 CHECK ALAN FLEENOR SKH DIF - LIBRARIES 253-0000-43200 0 $344.00' $344.00 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH. DIF -PARK 256-0000-43200 0. $40.00 $40.00 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH- MAINTENANCE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH DIF - STREET 255-0000-43200 0 $116.00 $116.00 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH MAINTENANCE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH Total Paid forDIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 TEMP POWER SERVICE 101-0000-42403 0 $24.17 $24.17 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH TEMP POWER SERVICE 101-0000-42403 0. $16.92 $16.92 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH. PC Total Paid for ELECTRICAL: $41.09 $41.09 RESIDENTIAL, EA 101-0000-42403 0 $98.64 $98.64 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH ADDITION 1,000SF RESIDENTIAL, EA 101-0000-42600 0 $40.64 $40.64 2/27/15 R3834 1074 r CHECK ALAN FLEENOR SKH ADDITION 1,000SF, PC RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH 1,0005E • • RESIDENTIAL, FIRST 101-0000-42600 0. $47.86 $47.86 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH 1,000SF, PC Total Paid forELECTRICAL - NEW CONSTRUCTION: $332.17 $332.17 RESIDENTIAL FINISH 101-0000-426000 $143.00 $143.00 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH GRADING PC Total Paid forGRADING: $143.00 $143.00 CONDENSER/COMPRES 101-0000-42402 0 $253.82 $253.82 2/27/15' R3834 1074 CHECK ALAN FLEENOR SKH SOR CONDENSER/COMPRES 101-0000-42600 0 $169.19 -$169.19 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH SOR PC Printed: Friday, February 27, 2015 3:15:34 PM 3 of 6 _sysrcMs -'DESCRIPTION - ACCOUNTQTY 7' w .. 'AMOUNT i - PAID"", - . __......�..�... PAID DATE .... RECEIPT# �,- ,... �.. t CHECK# METHOD ti.. 1,4PAIDBY, -...-,.-. LTD EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH EXHAUST HOOD PC 101-0000-42600 0 $4.83 $4.83 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH FURNACE, 101-0000-42402 0 $253.82 $253.82 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH FURNACE PC 101 0000-42600 0 $169.19 $169.19 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH VENT FAN 101-0000-42402 0 $169.26 $169.26 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH VENT FAN PC 101-0000-42600 0 $67.62 $67.62 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH Total Paid forMECHANICAL: $1,099.82 $1,099.82 NEW CONSTRUCTION PERMIT 101-0000-42400 0 $878.93- $878.93 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH Total Paid for NEW CONSTRUCTION PERMIT: $878.93 $878.93 NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $512.44 $512.44 2/27/15 R3834 1074 CHECK ALAN FLEENOR - SKH NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,400.00 $1,400.00 10/28/14 R2511 098052 CHECK FEDDERLY & ASSSOC. PJU Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,912.44 $1,912.44 BACKFLOW DEVICE 101-0000-42401 0 $12.09 $12.09 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $4.83 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH_ BUILDING SEWER 101-0000-42401 0 $12.09 $12.09 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH • BUILDING SEWER PC 101-0000-42600 0 $12.09 $12.09 2/27/15 83834 1074 CHECK ALAN FLEENOR SKH FIXTURE/TRAP 101-0000-42401 0 $314.34 $314.34 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH FIXTURE/TRAP PC 101-0000-42600 0 $314.34 $314.34 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH GAS SYSTEM, 5+ - OUTLETS 101-0000-42401 0 $36.26 $36.26 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 $24.17 2/27/15 R3834 1074 CHECK ALAN FLEENOR _ SKH WATER HEATER/VENT 101-0000-42401 0 $36.27 $36.27 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH Printed: Friday, February 27, 2015 3:15:34 PM 4 of 6 CRWIYSTEMS DESCRIPTION t , ACCOUNT QTY AMOUNT PAID PAID,DATE .RECEIPT# :PAID BY CLTD NON-STRUCTURAL JIM JOHNSON 10/28/2014 11/18/2014 11/18/2014 REVISIONS REQUIRED CORRECTIONS 1ST. PLAN CHECK CORRECTIONS BY WATER HEATER/VENT 101-0000-42600 0 $21.75 $21.75 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH PC APPROVED APPROVED ITEMS PENDING: SCHOOL FEES, P.M. 10, STRUC WATER SYSTEM 101-0000-42401 0 $12.09 $12.09 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH INST/ALT/REP 1/19/2015 1/28/2015 APPROVED APPROVED PLANS APPROVED ' SAMUELS WATER SYSTEM 101-0000-42600 0 $12.09 $12.09 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH INST/ALT/REP PC Total Paid for PLUMBING FEES: $812.41 $812.41 SMI - RESIDENTIAL 101-0000-20308 0 $94.93 $94.93 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $94.93 $94.93 SINGLE FAMILY 224-0000-20320 0 $1,837.44 $1,837.44 2/27/15 R3834 1074 CHECK ALAN FLEENOR SKH DETACHED -Total Paid forTUMF - RESIDENTIAL: $1,837.44 $1,837.44 TOTALS:40 PARENT PROJECTS INSPECTIONS REVIEWER SE ID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE .DATE . RESULT REMARKS . NOTES FINAL" NOTES PARENT PROJECTS REVIEW TYPE REVIEWER SENT DATE , DUE DATE REVIEWS RETURNED STATUS REMARKS NOTES DATE NON-STRUCTURAL JIM JOHNSON 10/28/2014 11/18/2014 11/18/2014 REVISIONS REQUIRED CORRECTIONS 1ST. PLAN CHECK CORRECTIONS STRUCTURAL JIM JOHNSON 10/28/2014 11/12/2014 12/1/2014 REVISIONS REQUIRED CORRECTIONS CORRECTIONS REQUIRED NON-STRUCTURAL JIM JOHNSON 1/9/2015 1/23/2015 1/22/2015 APPROVED APPROVED ITEMS PENDING: SCHOOL FEES, P.M. 10, STRUC APPROVAL. KATHRYN 2ND STRUC P/CTO YOUNG -DUE 1/23/16 STRUCTURAL 1/9/2015 1/19/2015 1/28/2015 APPROVED APPROVED PLANS APPROVED ' SAMUELS - Printed: Friday, February 27, 2015 3:15:34 PM 5 of 6 sysreMs 1ST PW GREEN I AMY YU 12/26/2015 I 3/5/2015 I 2/26/2015 I APPROVEDSHEET I I "BOND•' • Printed: Friday, February 27, 2015 3:15:34 PM 6 of 6 CRWIYSTrMS ATTACHMENTS Attaclir ent Type .. r . CREATED," OWNER: DESCRIPTION `F PATHNAME - `` ' SUBDIR` ETRAKIT ENABLED DOC 1/22/2015 JIM JOHNSON 80-325 VIA CAPRI.docx 80-325 VIA CAPRI.docx .0 ' CONSTRUCTION DEBRIS CONSTRUCTION DEBRIS DOC 2/26/2015 STEPHANIE KHATAMI MANAGEMENT PLAN MANAGEMENT PLAN.0 80325 VIA CAPRI 02-26- 80325 VIA CAPRI 02 -26 - is 15.pdf Printed: Friday, February 27, 2015 3:15:34 PM 6 of 6 CRWIYSTrMS Plan Submittal Job Site Building Permit Number. Project Description: SFR Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Owners Name Number, Street, or PO Box City, State, Postal Code Owners Phone Number Owner's E -Mall Address 2/26/2015 80-325 Via Capri (parcel #777-100-052) AI & Ami Fleenor 80100 Via Pessaro La Quinta, Ca. 92253 760-771-2475 ProjectManager'sNarnal August Iacono Project Managers Phone Number 951-634-6381 Project Managers E-mail Address I Auaust(Miaconodeveloomentcom Bulkier / Contra Number, Street or PO City, State, Postal C Monarch Homes Desert Division, Inc. 49951 Jefferson St. #130 Indio, Ca. 92201 Project Square Footage I approx.10,487 sq ft City Approval iBy IWA.UCL Date of City Approval 02dydI S Materials To Be Discarded: Product Tons Trash 41.75 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Recyclable Brick/Block 0.00 Recyclable Plaster 11.00 Recyclable Cardboard 0.00 Recyclable Scrap Metal 0.00 Recyclable Commingled 0.00 Recyclable Tile (floor) 0.75 Recyclable Concrete 44.00 Recyclable Tile (roof) 1.25 Recyclable Drywall 4.75 Recyclable Wood 13.75 Recyclable Donated / Reuse" 0.00 Recyclable Landscape Debris 0.00 Recyclable *Describe Items Totals: Recycle Trash 75.5 1 41.8 Projected Diversion: 64.39Yo I understand it Is the property owners responsibility to submit copies of weight tickets or receipts to the District Envkonrnental Coordinator as these hauls occur. I hereby certify that completion, knplementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted from IandfUUng. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demoiitfon o serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still Issued in the name orty owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adheredU;�' er(s) and general contractor shall be kept informed of the diversion progress through bNnonthy reportsfuse materiel from this project site must betaken to an approved recycler or transfer Date r, ,_J P.O. BOX 1504 BuildingSo-325 78-495 CALLE TAMPICO Address Uo - 3 2 5 Iii A CAAri LA QUINTA, CALIFORNIA 92253 Ad �,ailing v► � eccv�o Address �- 100 a (Cl PL9C�a City W` ow ma Zip'12253 Tel. X71 Z'f7 Contractor rr_dJeAu P��Gair_s - lwl State Lic. City q�1p & Classif. I(o2TgI Lic. # " 1� ! -71 Arch., En r., 11 I I - Designer g VOAAO,/1V 9 A -e v/ lac Address Tel. 3g' 41 � e 7(�D-��3-5205 city PlMWTk1e5 ipa 72,11 Lic t� I q9 -7 I hereby affi am � se and r i 6n f h r 9 (commencing with Section of Divisi of the � ess an P f io s ode d,Lny license is in full with -e� ion I eby affirm that 1 am exempt from the Contractor's License Law for the following reason: 031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not appy to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). 171, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not appy to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Cc pensatio insurance or a certified cop thereof (S c. 3800, Labor de.)1 Policy No. — Company OI,�.+_�,.1'Ie1'�J1 ❑Copy is tiled with the city. PJl�ertified copy is hereby furnished. QK�v CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT .Itis lotf APPLICATION ONLY BUILDING: TYPE CONST. OCC. GRP. ^'"3� A.P. Number -1,, 100 _ QST Legal Description LJl I IF cF a(f 29 1Rq'i Project Description 71 In SFt. % t�• Cuacheila Valley Unified School District 83-733 Avenue 55, Thermal, CA- 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name:jI he Hideaway Date: " 'February 27, 2015 Owner's Name:' Alan Fleenor Phone No. 951-634-6381 Project Address: 80-325 Via Capri, LaQuinta Project Description: New SFD APN: 777-100-052 Tract #:, Lot #'s: Type of Development: Residential XX! Commercial Industrial: Total Square Feet of Building Area: 8,522" Certification of Applicant/Owners: The person signing certifies that the above inform, on -is -co e t and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of owner/dev er. Dated: February 27, 2015. Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) E LL BE SATISFIED IN Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1%1/87 Requirement Note: Number of Sq.Ft. 8522Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile Amount per Sq.Ft. $3.36homes being relocated within the same school district's' . Amount Collected . $28633.92 jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature: ,Q,(�G�p� NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only foe good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs/devfees/certificate of compliance fonn updated 3-2007 " 11/2010 r� J i RECORDING REQUESTED BY: Lawyers Title - IE WHEN FIECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: the Alan and Ami L. Fleenor Trust ...�• `�oas S�S�Lc.t� - t� z-�o • Order No.:14, t2;L-i-t Escrow No.: PDL10160-CM A.P.N.: 777-100-052 77�t 0�0 —� NT DEED _ THE UNDERSIGNED GRANTOR(S) DECLARE(S)DOCUMENTARY TRANSFER TAX O computed on full value of property conveyed D City of La Quinta I FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, William V. Anderson and Teri L. Anderson, Trustees of the Anderson Family Trust, U.D.T. dated September 13, 2007 hereby GRANT(S) to Alan A. Fleenor and Ami L. Fleenor, Trustees of the Alan; A. and Ami L. Fleenor Trust dated 10/1/2004 - GRA Dr` # 2009-0220523 05/04/2009 08:00A Fee:12.00 Page 1 of 2 Doc.T Tax Paid Recorded in'Official Records ' County of Riverside ' t 5' Carry W. Ward Assesso'r,.,'County Clerk &.Recorder I IfIIII.IIIIIII IIII IIIIII IIID ISI �Ill�il III �Ilfl IIII ILII S -T- RU AGE SIZE DA MISC :LONG RFD COPY M A L 465426 PCOR COR SMF NCHG EXAM + . T T UNI the following described real property in the County of Riverside, State of California Legal Description attached as' Exh)bit 'A' - Dated: April 27, 2009 ' State of Califon ' County f 1��4e"StCe ss On �-�� i �, before me a Notary Public, personally appeared the Anderson Family Trust, U.D.T. dated September i L k y arv, ndcr-'Sta n 2007 Gr► , L— - VkqMrspo .. 1� . , �,-- L(z'�L' <�'/ who proved tc,me on,the besis of satisfactory evidence,to be the persons whose nam s�s/are subscribed to the ` 'n �y 'v1i'i..:r' V: iiderson; ru�tee instrument and, acknowledge o me that he/sh /t e executed the same' his/he th i authorized capacity ) and that by his/her theTjsignatuQj) on the instrument e y .• eri L. Anderson, Trustee personso or the enti upon behalf of which•the persor6). 4- 1-1 o 01 acted, executed the instrument. , I certify under PENALTY OF PERJURY under the laws of Im t. ilk the State of Car rnia that the foregoing paragraph is true Arm Gommkom O it and correct. Notwy ttibiiie . C> eplO WITNESS my and d official seal. Rlwrsi4o Costly Signature. TY, . �UV • 161 120/ 0 Signature of Notary ' (This area for official notary seal) „ MAIL TAX STATEMENTS AS DIRECTED ABOVE F 1 EXHIBIT "A" File No: 69612279 All that certain real property situated in the County of Riverside, State of California, described as follows: Parcel No. 1: Lot ii, of Amended No. 2 of*— ract No. 29894-2, in the City of La Quinta, County of Riverside, State of California, as per map recorded In Book 359, page(s) 68 to 82, Inclusive, of Maps, in the office of the County Recorder of said County. Parcel No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration Assessor's Parcel Number;. (777-100-052) JA IV cln, 0 9 20J5 CDNjMUrvITYD�� �UIkTA V �CCPt`�F/VT May 21, 2014 Mr. and Mrs. Al Fleenor 80100 Via Pessaro La Quinta, CA 92253 Re: Lot 11F at 80325 Via Capri Construction Document Review #1 Dear Mr. and Mrs. Fleenor, The Hideaway Design Review Committee (DRC) received your final working drawings for review at their May 20, 2014 meeting. The project was approved to start construction. As a courtesy comment only, the committee noted that Carissa may be prone to freezing in the winter months which may become a maintenance and replacement issue for you in the future. If another plant material is selected please submit your change for review prior to installation. Any future submittals from the design team should include revision deltas and dates. We look forward to working with you during the construction process. Please contact Brook Marshall at 760-219-8057 or by email at DRCFacilitator@gmail.com with any questions regarding this review or to schedule your Pre -Construction Meeting once a Building Permit has been received. As a reminder, final approvals are valid for a one-year period. Sincerely, The Hideaway Design Review Committee cc: Lance Fedderly Alfleenor@comcast.net DRC File r \\ BUILDING ENERGY ANALYSIS REPORT PROJECT: The Fleenor Residence , 80-325 Via Capri, The Hideaway La Quinta, Ca 92253 Project Designer: Fedderly and Associates 38-747 Nopales Road Palm Desert, Ca 92253 (760) 773-0875 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive 'Palm Desert, Ca 92211 (760) 200-4780 Job Number: R" EE I c! rF E3UILafNGjk F� (VTA Date: 7YQP'T, 11. 1/7/2015 F 126 N MEN JDATEI/2�—Z The EnergyPro computer program has been used to perform the calculations summarized in this compliance-rep9rt. This pro pproval a d is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Efiergy-Eifi 'enGi cy�t'andard,�: This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5. 1 by EnergySoft User Number: 6712 Run Code: 2015-01-07T15.38:15 ID: • 1� PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Fleenor Residence Building Type m Single Family O Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 Project Address 80-325 Via Capri, The Hideaway La Quin California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,522 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 8,522 Radiant Barrier New Wall Wood Framed R-21 6,748 New Slab Unheated Slab -on -Grade None 8,522 Perim = 784' New Door Opaque Door None 48 New Door Opaque Door None 376 Int --R-8.0 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (SE) 30.0 0.390 0.39 none none Bug Screen New Rear (SIM 350.0 0.390 0.32 none none Bug Screen New Right (NIM 60.0 0.390 0.32 none none Bug Screen New Front (NE) 396.5 0.390 0.32 none none Bug Screen New Front (NE) 60.0 0.390 0.39 none none Bug Screen New Front (NE) 70.0 0.390 0.32 2.0 none Bug Screen New Front (NE) 50.0 1.040 0.38 2.0 none Bug Screen New Left (SE) 166.5 0.390 0.32 none none Bug Screen New Rear (SW) 384.0 0.390 0.39 22.0 none Bug Screen New Right (NIM 144.0 0.390 0.39 none none Bug Screen New Right (NIM 27.0 0.390 0.39 18.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 3 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2, 3 & 4 Ducted HVAC 5 & 6 Ductless/ with Fan Ducted Attic, Ceiling lens vented ----��--. 8.0 New Ductless n/a I y V F LAn/n I i i K 7i -a- 3 WATER HEATING bUILD"NG & SAFETY DEPT -• Qty. Type Gallons Min. Eff Distribut or` jj ,Qt -N,1 .er- 5tItus 1 Instant Gas 1 0.70 All Pipes InsFUh-I COijI '_' I� Ne 1 Instant Gas 1 0.70 All Pipes Ins v Ne 1 Instant Gas 1 0.70 A11,Pipe0ns v Ne EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2015-01-07715:38:15 ID: a e 3 of 35 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Fleenor Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 Project Address 80-325 Via Capri, The Hideaway La Quini, California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,522 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. 0 Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity f Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (SIM 80.0 0.390 0.39 none none Bug Screen New HVAC SYSTEMS Qty- Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 7 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING � BUILD1NGr& SAFETY D � Qty. Type Gallons Min. Eff Distribution„ ,.,._ -�, _ES�tus f--,- - r- r-� - ✓! J u"O I HUCTION EnergyPro 5.1 by EnergySoft User Number., 6712 Run Code: 2015-01-07T15:38:15 ID: a 4 of 35 • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name The Fleenor Residence Building Type ®Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 1/7/2015 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design -Verily Thermal Mass: 1,010.0 ftz Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 476.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite The HVAC System HVAC 2, 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 330.0 ft2Covered Slab Floor, 3.500" thick at Living/Kitchen/Dining/Office HIGH MASS Design - Verify Thermal Mass: 3,526.0 ft2 Exposed Slab Floor, 3.500" thick at Living/Kitchen/Dining/Office HIGH MASS Design - Verify Thermal Mass: 329.0 ft2 Covered Slab Floor, 3.500" thick at Bed 2 HIGH MASS Design - Verify Thermal Mass: 104.0 ft= Exposed Slab Floor, 3.500" thick at Bed 2 The HVAC System HVAC 5 & 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,591.0 ft2 Exposed Slab Floor, 3.500" thick at Garage 1 & 2 The HVAC System HVAC 7 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 719.0 ft' Covered Slab Floor, 3.500" thick at Guest Suite HIGH MASS Design - Verify Thermal Mass: 437.0 ft2 Exposed Slab Floor, 3.500" thick at Guest Suite HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA760158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA760/58CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verity the installation of the correct Condenser. The HVAC System HVAC 2, 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2, 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA748156CVXI 10 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 7 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 7 incorporates HERS verified Duct Leakage. HERS field verification -and -diagnostic testing is required to verify that duct leakage meets the specified criteria. + Cl r UUINTA BUILDING Ac '_ 10 —UurdSTBUCTION DATE- BY Ene Pro 5.1 b Ene Soft User Number: 6712 Run Code: 2015-01-07T15:38:15 D: e 5 of 35 L-A PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name The Fleenor Residence Building Type 0 Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1 1/7/2015 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. uiI Y Uo- LA QUINTA ! III Klrr Q Q n r M A f–' R�— — FOR CONSTRUCTION DATE R EneMyPro 5.1 by EneMySoft User Number. 6712 Run Code: 2015-01-07T15:38: 3-----I Pa e 6 of 35 • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date The Fleenor Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 117/2015 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ft2- r Space Heating 4.00 4.44 -0.43 Space Cooling 51.21 39.59 11.63 Fans 10.11 11.99 -1.88 Domestic Hot Water 4.28 3.58 0.70 Pumps 0.00 0.00 0.00 Totals 69.60 59.59 10.01 Percent Better Than Standard: 14.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 2,358 577 Fuel Available at Site: Natural Gas (SE) 1,884 197 Raised Floor Area: 0 (SK9 2,599 814 Slab on Grade Area: 8,522 (Nw) 2,149 231 Average Ceiling Height: 11.4 Roof 8,522 0 Fenestration Average U -Factor: 0.41 TOTAL: 1,818 Average SHGC: 0.35 Fenestration/CFA Ratio: 21.3 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 1!1/1015 City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and-building_enxelope sealing require installer testing and certification and field verification by an approved HERS rater 8TH' OF LA QUIN TA Designer or Owner (per Business & Professions Code) BUILDING & SAFETY DEPT. -4� Company Fedderly and Associates 6�i p w,� Address 38-747 Nopa/es Road Name Fedderly and Associates F: 1k (t�jtla -� �� City/State/ZipCity/State/Zip Palm Desert, Ca 92253 Phone (760) 773-0875 Signed Lice nse #"� ate ~ Y EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2015-01-07715:38:15 ID: of 35 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R .Project Name The Fleenor Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1 117/2015 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 1,486 0.026 R-38 270 0 New 4.2.1-A9 Master Suite Wall 225 0.069 R-21 45 90 New 4.3.1-A6 Master Suite Wall 156 0.069 R-21 135 90 New 4.3.1-A6 Master Suite Wall 424 0.069 R-21 225 90 New _ 4.3.1-A6 Master Suite Wall 410 0.069 R-21 315 90 New 4.3.1-A6 Master Suite Slab 1,010 0.730 None 0 180 New 4.4.7-A1 Master Suite Slab 476 0.730 None 0 180 New 4.4.7-A 1 Master Suite Roof 3,856 0.026 R-38 270 0 New 4.2.1-A9 Living Zone Wall 4391 0.069 R-21 45 90 New 4.3.1-A6 LivinZone Door 241 0.500 None 45 90 New 4.5.1-A4 Livin Zone Wall 5871 0.069 R-21 135 90 New 4.3.1-A6 Living Zone ,. Wall 456 0.069 R-21 225 90 New 4.3.1-A6 Living Zone Wall 447 0.069 R-21 315 90 New 4.3.1-A6 Living Zone Slab 330 0.730 None 0 180 New 4.4.7-A1 Mvin2 Zone Slab 3,526 0.730 None 01 180 New 4.4.7-A1 Living Zone Roof 433 0.026 R-38 _ 2701 0 New 14.2.1-A9 JBed 2 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC4 Azm Status Glazing Type Location/Comments 1 Window 30.0 0.390 NFRC 0.39 NFRC 135 New Dual Non Metal Tinted Door Master Suite 2 Window 120.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Master Suite 3 Window 6.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Master Suite 4 Window 40.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Master Suite 5 Window 6.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Master Suite 6 Window 10.0 0.390 NFRC ^ 0.32 NFRC 225 New Dual Non Metal Tinted Master Suite 7 Window 24.0 0.390 NFRC . 0.32 NFRC 315 New Dual Non Metal Tinted Master Suite 8 Window 39.0 0.390 NFRC , 0.32 NFRC 45 New Dual Non Metal Tinted Living Zone 9 Window 60.0 0.390 NFRC ' 0.39 NFRC 45 New Dual Non Metal Tinted Door Living Zone 10 Window 39.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Living one 11 Window 62.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Living Zone 12 Window 108.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted living Zone 13 Window 35.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Living Zone 14 Window 50.0 1.040 NFRC 0.38 NFRC 45 New Custom Door Living Zone 15 Window 35.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Living Zone 16 Window 12.5 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Living Zone (1) U -Factor Type: 116-A =Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt 'RExt Dist Len Ri ht Fin Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 1 fL, I I 'y'" : I n, so , 12 Bu Screen 0.76 I p `-.,. i L 1 E i 13 Bu Screen 0.76 10.0 3.5 2.0 0.1 2.0 2.0 _ °` `J' wtia & 6Ai=F pT 14 Bu Screen 0.76 10.0 5.0 2.0 0.1 2.0 2.0 e R" r-1' -�, , f ` 15 IBug, Screen 0.76 10.0 3.5 2.0 0.1 2.0 (2.0 i- `, ° _ r 1 %--J' V C-- I__J 16 Bug Screen 0.76 ` Y V U T,4 `v j R DATE Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2015 -01 -07T15:38:1.5 ----_JD- - �� e of 35 L] • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name The Fleenor Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation I Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 215 0.069 R-21 45 90 New 4.3.1-A6 Bed 2 Wall 217 0.069 R-21 135 90 New 4.3.1-A6 Bed 2 Wall 420 0.069 R-21 225 90 New 4.3.1-A6 Bed 2 Wall 112 0.069 R-21 315 90 New 4.3.1-A6 Bed 2 Slab 3291 0.730 None 1 0 180 New 4.4.7-A1 Bed 2 Slab 1041 0.730 None 0 180 New 4.4.7-A1 Bed 2 Roof 1,591 0.026 R-38 270 0 New 4.2.1-A9 Garage 1 & 2 Wall 414 0.069 R-21 45 90 New 4.3.1-A6 Garage 1 & 2 Door 144 0.106 None 18.0 None 45 90 New 4.5.1-A2 Garage 1 & 2 Wall 400 0.069 R-21 135 90 New 4.3.1-A6 Garage 1 & 2 Wall 160 0.069 R-21 225 90 New 4.3.1-A6 Garage 1 & 2 Wall 3431 0.069 R-21 315 90 New 4.3.1-A6 Garage 1 & 2 . Door 24 0.500 None 315 90 New 4.5.1-A4 Garage 1 & 2 .. Door 96 0.106 None 8.0 None 315 90 New 4.5.1-A2 Gara e 1 & 2 Door 136 0.106 None 8.0 None 315 90 New 4.5.1-A2 Garage 1& 2 . Slab 1,591 0.730 None 0 180 New 4.4.7-A1 Garage 1 & 2 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 50.0 0.390 NFRC 0.32 1 NFRC 135 New Dual Non Metal Tinted Living Zone 18 Window 20.0 0.390 1 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Living Zone 19 Window 17.5 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Living Zone 20 Window 17.5 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Living Zone 21 Window 36.0 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Living Zone 22 Window 81.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Living Zone 23 Window 384.0 0.390 NFRC 0.39 NFRC 225 New Dual Non Metal Tinted Door Living Zone 24 Window 72.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Living Zone 25 Window 96.0 0.390 NFRC 0.39 NFRC 315 New Dual Non Metal Tinted Door Living Zone 26 Window 27.0 0.390 NFRC 0.39 NFRC 315 New Dual Non Metal Tinted Door Living Zone 27 Window 12.5 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Bed 2 28 Window 12.5 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Bed 2 29 Window 7.5 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Bed 2 30 Window 6.0 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Bed 2 31 Window 48.0 0.390 NFRC 0.39 NFRC 315 New Dual Non Metal Tinted Door Bed 2 32 Window 6.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted 1 Garage 1 & 2 (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC ' Window H t Wd Ove hanq Left Fin Len Hot I LExt RExt Dist Len Ri ht Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 12.0 32.0 22.0 0.1 22.0 22.0 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 9.0 3.0 18.0 0.1 18.0 18.0-- 27 Bug Screen 0.76 r �T 28 Bug Screen 0.76 -' Y 1 r ( A n - 29 Bug Screen 0.76 ( �,[ jlt f t s� 1\1 30 Bug Screen 0.76 31 JBug Screen 0.76 ( Al �, . a ;; 32 IBug, Screen 0.76 rf _�� s f C ' "' f UCTION EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2015-01-07T15:3 :1 " Pa 9 of 35 • 1� CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name The Fleenor Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FactorVR-21 Roof 1,156 0.026 270 0 New 4.2.1-A9 Guest Suite Wall 321 0.069 45 90 New 4.3.1-A6 Guest Suite Wall 328 0.069 135 90 New 4.3.1-A6 Guest Suite Wall 325 0.069 225 90 New 4.3.1-A6 Guest Suite Wall 350 0.069 R-21 315 90 New 4.3.1-A6 Guest Suite Slab 719 0.730 None 0 180 New 4.4.7-A1 Guest Suite Slab 437 0.730 None 0 180 New 4.4.7-A1 Guest Suite FENESTRATION SURFACE DETAILS ID Type I Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 6.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Garage 1 & 2 34 Window 6.0 0.390 NFRC 0.32 NFRC 315 New Dual Non Metal Tinted Garage 1 & 2 35 Window 35.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Guest Suite 36 Window 56.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Guest Suite 37 Window 8.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Guest Suite 38 Window 6.0 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Guest Suite 39 Window 6.0 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Guest Suite 40 Window 48.0 0.390 NFRC 0.39 NFRC 225 New Dual Non Metal Tinted Door Guest Suite 41 Window 15.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Guest Suite 42 Window 32.0 0.390 NFRC 0.39 NFRC 225 New Dual Non Metal Tinted Door Guest Suite 43 Window 15.0 0.390 NFRC 0.32 NFRC 315 New Dual Non Metal Tinted Guest Suite 44 Window 15.0 0.390 NFRC 0.32 NFRC 315 New Dual Non Metal Tinted Guest Suite (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hanq Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 r- • _ ,__ 42 Bug Screen 0.76�--- 43 BLkq Screen 0.76 44 Bug Screen 0.76 ()!W' FP r- La"..r VISI EnergyPro 5.1 by EnergySoft User Number., 6712 Run Code: 2015-01-07715:38:15 ID: Pa 1 of 35 C CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name The Fleenor Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1 1/7/2015 BUILDING ZONE INFORMATION System Name Floor Area Zone Name New Existina I Altered Removed Volume Year Built HVAC 1 Master Suite 1,486 16,346 HVAC Z 3 & 4 Living/Kitchen/Dining/Office 3,856 48,586 Bed 2 433 4,330 HVAC 5 & 6 Garage 1 & 2 1,591 1 15,910 HVAC 7 Guest Suite 1,156 11,560 Totals 8,522 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Fumace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 2,3 & 4 3 Central Fumace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 5 & 6 2 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New HVAC 7 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION System Name Duct Heating Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2,3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 5 & 6 Ductless /with Fan Ductless n/a n/a ❑ New HVAC 7 Ducted Ducted Attic, Ceiling Ins, vented 8.01 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Bradford White #IGI-180R 1 Instant Gas All Pipes Ins 180,000 1 0.70 n/a n/a New Bradford White #IGI-180R 1 11nstantGas 1AH Pipes Ins 1 180,0001 1 0.70 1 n/a I n/a New Bradford White #IGI-180RI 1 1 Instant Gas I All Pipes Ins 1 180,0001 1 1 0.70 1 n/a I n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 0 ca — FC I l_Y �" �� ste.maName,Ir_ o ----._ FPPea� L1IPgpe Len th_ Dianne {e nsul. Thick. Qty. HP Plenum Outside Buried ❑ {{S 3 Il 1, - - *-PYf_r- t Y DEPT - 0 w -r- ❑ EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2015-01-07715:38:15 ID: Pa 11 of 35 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name he Fleenor Residence Date 1/7/2015 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures:. 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all 'oints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection re uirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >f5 s'i'meets-the-requiFements-oLS.ta rds Table 123-A. F � _ (� f t t N t A ta.i Y Y 'U tl IAi 4150(0)3A: Insulation is protected from damage, includingthat due to sunlight, moistures a Ui-'ment_maintenanse-and win -,.. . §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes avapor retardant or is enclose'd'e tires i - conditioned space. I APP R n` A= r §150(0)4: Solar water -heating systems and/or collectors are certified by the Solar Rating an6Certific6iion- O'r' o_ fation. f DAT EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2015-01-07715:389.5 !D. age 12 of 35 4 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date he Fleenor Residence 1/7/2015 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Liqhting integral to exhaust fans in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable c�ontroL syst_ em; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are°high eff—Poo and -controlled b a �rr manual -on occupant sensor. M i jr OF 1 A nj §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more thin 20�watts;of�powexr f' �IrlYo illuminated cabinet. . DEPT ED FOR CONSTRUCTION DATE EnergyPro5.1 byEnergySok User Number: 6712 RunCode:2015-01-07715:38:15 _""---ID: . _----Page_i3 f35 4 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date The Fleenor Residence 1/7/2015 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. '!� ® �vls✓oING INTq � & �, DEPT. Alf. TFOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoff User Number: 6712 Run Code: 2015-01-07T15:38:15 ID: Page of 35 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name he Fleenor Residence Date 1/7/2015 System Name HVAC 1 Floor Area 1,486 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM 623 14,065 1,128 319 0 812 0 0 0 0 0 0 1 8121 15,689 1,128 PEAK Heating System Sensible Output perSystem 110,000 17,270 Total Output Btuh 110,000 Output Btuh/s ft 74.0 849 Cooling System 0 Output perSystem 59,0001 0 Total Output Btuh 59,000 0 Total Output ons 4.9 849 Total Output Btuh/s ft 39.7 Total Output s ft/Ton 302.2 1 18,967 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24APA760/58CVX110 46,779 4,254 110,000 Airflow cfm/s ft 1.35 Airflow cfm/Ton 406.8 Total Adjusted System Output for Peak Design conditions) TIME OF SYSTEM PEAK 46,779 4,254 110,000 Aug 3 PM Jan 1 AM Outside Alr % 0.0% Outside Air cfm/s ft 0.00(Adjusted e: values above iven at ARI conditions L't ATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan AL 2,000 cfm 70 OF 70 OF 121 OF Heating Coil 121 ,F (ROOM WHE 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/63°F 78/63°F 56/55°F c Outside AirAr 0 cfm Supply Fan Cooling Coil 2,000 cfmpUl!_pj,r�G 78 / 63 OF , P'y-�� f i OF LA Q 1 t� / 55 F 0 J . eea�44.2 p% A' a P FU1-i CONSTRV iC— 78/6 OF DATE �— BY EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2015-01-07715:38:15 ID: Pae 112f 35 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date �he Fleenor Residence 1/7/2015 System Name Floor Area HVAC 2,3 & 4 4,289 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL COOLING PEAK COIL HTG. PEAK Heatino Svstem I CFM Sensible Latent CFM Sensible Total Cool Total Total Total 110,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 330,000 76.9 59,000 177,000 14.8 41.3 290.81 2,613 58,390 3,078 1,090 58,882 0 3,371 2,894 0 0 0 0 0 0 0 0 0 3,371 2,894 65,132 64,669 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 6,000 Carrier 24APA760/58CVX110 140,795 12,460 330,000 Airflow cfm/s ft 1.40 Airflow cfmfTon 406.8 Outside Air % 0.0% Total Adjusted System Output 140,795 12,460 330,000 Outside Air cfm/s ft 0.00 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 70 OF 121 OF C!0]Outside Air 0 cfm Supply Fan Heating Coil 121 OF 6,000 cfm ROOM 70 OF 70 OF 14 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/63°F 79/63°F 56/55°F :QHS — Outside Air 0 gg �o 0 cfm Supply Fan Cooling Coil t i F LA QUI. ° 6,000 cfm BUILDING & aa,.2,/° 0�0111AE 79 / 63 °F©� CONST RUCTIO 78 / 63 OF GATE EnergyPro 5.1 by EnergySoR User Number: 6712 Run Code: 2015-01-07T15:38:15 ID: Page 6 of 35 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Fleenor Residence Date 1/7/2015 System Name HVAC 5&6 Floor Area 1,591 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 2 COIL CFM Total Room Loads 293 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 24,000 9,674 1,037 681 17,459 Total Output Btuh 48,000 0 Output Btuh/s ft 30.2 0 0 Cooling System 0 0 Output per System 24,000 0 0 0 0 Total Output Btuh 48,000 0 0 1 9,674 1,037 0 Total Output ons 4.0 0 Total Output Btuh/s ft 30.2 Total Output s ftrron 397.8 1 17,459 Air System CFM per System 585 HVAC EQUIPMENT SELECTION Airflow cfm 1,170 Fujitsu #24RLXFW 38,614 0 29,979 Airflow cfm/s ft 0.74 29,979 Jan 1 AM Airflow cfm/Ton 292.5 Outside Air % 0.0% Total Adjusted System Output 1 38,614 0 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 94 OF ^^ 94 OF tn� Heating Coil Supply Fan 1,170 cfm 94 OF ROOM 70 OF riI COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 78 / 59 OF 78/59°F 47/45°F 47/45°F 007. Cooling Coil Supply Fan C I 1 i OFF LA QUI N177 45t°F 1,170 cfm BUILDING & SAFETY DE 30:4'% ROOM I-, ' Rt wr p i FOR CONSTRUCTION / 59 OF DATE BY EnergyPro 5.1 by EnergySoff User Number: 6712 Run Code: 2015-01-07T15:38:15 ID: Page 1of 3 4 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name he Fleenor Residence System Name HVAC 7 Date 1/7/2015 Floor Area 1,156 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 636 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 13,760 922 319 17,414 Total Output Btuh 89,000 0 Output Btuh/s ft 77.0 794 856 Cooling System 0 0 Output per System 46,500 0 0 0 0 Total Output Btuh 46,500 0 794 1 15,348 922 0 Total Output Tons 3.9 856 Total Output Btuh/s ft 40.2 Total Output s ft/Ton 298.3 19,126 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24APA748/58CVX110 36,197 4,334 89,000 Airflow cfm/s ft 1.38 89,000 Jan 1 AM Airflow cfm/Ton 412.9 Outside Air % 0.0% Total Adjusted System Output 36,197 41334 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3P M Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 10 Outside Air 0 cfm 69 OF 69 OF 122 OF 122 OF Heating Coil Supply Fan 1,600 cfm 121 OF ROOM 70 OF rnI COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 78 / 64 OF 78/64°F 57/56°F 57/56°F i� c a t Supply FanOF Q U I N V 58 6 F Cooling Coil BUILDING & SI, -1FTY-DEP- 1,600 cfm FOR CONSTRUCTION78 / 64 IF I DATE BY EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2015-01-07T15:38:15 ID: Page 18 of 35 ,f6 ROOM LOAD SUMMARY 623 14,065 1,128 319 1,270 Project Name The Fleenor Residence System Name HVAC 1 Date 1/7/2015 Floor Area 1,486 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mutt. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Suite Master Suite 1 623 14,065 1,128 623 14,065 1,128 319 17,270 iTV tomI A 0al l R1 III_ nimr` -9 SAFE j Fv/ aE • Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL ' r cs ti 9_i4J V MU 623 ''" 1.4Alb jB��4 ;TIQH 1:1270 DATE __ BY Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2015-01-07715:38:15 9 f 35 ,f6 623 14,065 1,128 319 1,270 • • ROOM LOAD SUMMARY z L,090 5 ,882 2,6F3 3H �8�?�0� ^Ta;� Project Name The Fleenor Residence 5 ,882 Date 1/7/2015 System Name HVAC 2, 3 & 4 Floor Area 4,289 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Living Zone Living/Kitchen/Dining/Otfi 1 2,326 51,977 2,608 2,326 51,977 2,608 937 50,640 Bed 2 Bed 2 1 287 6,413 470 287 6,413 470 153 8,241 ' Total includes ventilation PAGE TOTAL TOTAL . �Ei r .% ry^ 2,613•q �1 59�,0 A -,3,078r z L,090 5 ,882 2,6F3 3H �8�?�0� ^Ta;� `Tj0�90 5 ,882 • r1 • ROOM HEATING PEAK LOADS Project Name The Fleenor Residence Date 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Floor Area 1,486.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 1,486.0 X U -Value AT °F Btu/hr X 44 = 1,700 X 44 = 3,689 X 44 = 515 X 44 = 3,535 X 44 = 4,208 X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = Page Total 13,646 -60,3624u _ I r 11 INTA BUILDING & SAFETY D r-„ r-, p. EFT. R-38 Roof(R.38.2x12.16) 0.0260 R-21 Wall (W.21.2x6.16) 1,215.0 X X 0.0690 Dual Non Metal Tinted Door 30.0 0.3900 Dual Non Metal Tinted 206.0 X X X X X X X 0.3900 Slab -On -Grade perim = 131.0 0.7300 X X X X X X X X X X X X X X X X X X X X X through an interior surface to X 1,486 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room 11.00 X 10.284,j—/ Height CH'" r TOTAL HOURLY HEAT LOSS FOR ROOM UVPr- 1727°0 U11 UNSTRUCTION 1,17 Energ Pro 5.1 by EnergySoft User Number. 6712 Run Code: 2015-01-07T15:38:15 lD Page 23 of C C, r • ROOM HEATING PEAK LOADS Project Name The Fleenor Residence 71/7/2015 Date ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Kitchen/Dining/Office Floor Area 3,856.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 3,856.0 X 0.0260 X 1,928.5 X 0.0690 X 24.0 X 0.5000 X 624.5 X 0.3900 X 567.01 X 0.3900 X 50.0 X 1.0400 X perim = 240.0 X 0.7300 X X X X X X X X X X X X X X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x through an interior surface to another room X 3,856 X 12.60 x 0, ., Area Ceiling Height AC-1t� AT *F Btu/hr 44 = 4,411 44 = 5,855 44 = 528 44 = 10,716 44 = 9,730 44 = 2,288 44 = 7,709 �> Page Total 41,237 / iQ �X W- 4• _�FIJ A9,4 3 L�i�`QG vAbTt Y DEPT. A P P R OWE D R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) Wood Door Dual Non Metal Tinted Dual Non Metal Tinted Door Custom Door Slab -On -Grade Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 x 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM F a'�- e I H U (; I ION 550,65 0 nATC: i EnergyPro 5.1 by Energ Soft User Number: 6712 Run Code: 2015-01-07715:38:15 ID: —� BY=Pa a 29 0 5 J ROOM HEATING PEAK LOADS Project Name The Fleenor Residence Date 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Bed 2 Floor Area 433.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value 433.0 X 0.0260 X 963.5 X 0.0690 X 38.5 X 0.3900 X 48.0 X 0.3900 X perim = 71.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 433 X 10.00 X[AWnC811LD11'NG Area Ceiling Height AT *F Btu/hr R-38 Roof(R.38.2x12.16) 44 = = 495 R-21 Wall (W.21.2x6.16) 44 2,925 Dual Non Metal Tinted 44 = 661 Dual Non Metal Tinted Door 44 c = = = = = 824 Slab-On-Grade 44 2,281 = = = = = = = = = = = = = = o = = = = = = Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction Page Total 1� 7,185 I JTA 1,056 DEPT. Uar X J & SAI"TETY TOTAL HOURLY HEAT LOSS FOR ROOM FnR (` ims ) 8,241 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2015.01-07T15:38:15 DA lQ' BY fam, 35 1 J ROOM HEATING PEAK LOADS Project Name The Fleenor Residence Date 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage 1 & 2 Floor Area 1,591.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X 0.0690 X 0.3900 AT *F Btu/hr R-38 Roof(R.38.2x12.16) 1,591.0 X X X X X 44 = = = = = 1,820 R-21 Wall (W.21.2x6.16) 1,317.0 44 3,998 Dual Non Metal Tinted 18.0 44 309 Insulated Garage Door 376.0 X X X 0.1061 44 1,755 Wood Door 24.0 0.5000 44 528 Slab -On -Grade perim = 180.0 0.7300 X X X X 44 = = = = 5,782 X X X X X X X X = = = X X X X X X X X X = X X X = = = X = X X = = X X X X X X X X X = = = = = = = = X X X X X X X X X X X to another room 10.00 X �0'2Z Ceiling Height EA9JHLDENG X X X = = = X = Page Total Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,591 X Area 14,192 t�' [F 60]]X -A k�t441t & SAV-oTl� 267 v r I - TOTAL HOURLY HEAT LOSS FOR ROOM FUI-i C:UIVb I HUC. I IUN 17 59 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2015-01-07715:38:15 ,- ID,---Page-26 • f 35 C� i 17-1 ROOM HEATING PEAK LOADS Project Name The Fleenor Residence Date 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite Floor Area 1,156.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 1,156.0 X 0.0260 1,324.0 X 0.0690 156.0 X 0.3900 80.0 X 0.3900 perim = 162.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 1,156 X 10.00 X ('0,312�/��_ Area Ceiling Height ACO BUILDING X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X A9, AT *F Btu/hr 44 = 1,322 44 = 4,020 44 = 2,677 44 = 1,373 44. = 5,203 = = = = = = = = = = = = = = = = = = = = = = = = = = Page TotalF 14,595 X �� _ 819 1-.r"1 V & SAFETY DEPT. r -t row A �— R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) Dual Non Metal Tinted Dual Non Metal Tinted Door Slab -On -Grade Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM '- V C-- LJ 1,414 rU�CONs I HUCTION EnergyPro 5.1 by Ene Soft User Number. 6712 Run Code: 2015-01-07T15:38:1� ID: Page 2 of 35 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Fleenor Residence 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,486.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) (W) 1,486.01 X 0.0260 X 56.0 = 2,164 R-21 Wall (W.21.2x6.16) (NE) 225.0 X 0.0690 X 29.0 = 450 R-21 Wall (W.21.2x6.16) (SE) 156.0 X 0.0690 X 31.0 = 334 R-21 Wall (W.21.2x6.16) (SIM 424.0 X 0.0690 X 31.0 = 907 R-21 Wall (W.21.2x6.16) (NM 410.0 X 0.0690 X 30.2 = 855 X X = X X = X X = X X = Page Total 4,710 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 8 (SE) 0.0 X 22.3 + 30.0 X 31.2 = 937 J (SVt9 0.0 X 19.7 + 120.0 X 27.0 = 3,245 F (SW) 0.0 X 19.7 + 6.0 X 27.0 = 162 H (S VV) 0.0 X 19.7 + 40.0 X 27.0 = 1,082 F (SVV) 0.0 X 19.7 + 6.0 X 27.0 = 162 G (SVt,9 0.0 X 19.7 + 10.0 X 27.0 = 270 ? (NV19 0.0 X 19.7 + 24.0 X 30.0 = 719 X + X - X + X - Page Total 6,578 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 81.31 X 34 = 2,548 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,065 Latent Gain �+ �tto/hr Occupants 1.0 Occupants X I � � 9 200 g{5h/LcA QUI N 200 � BUILDING PY SAFETY DEPT. Infiltration: X 0.87 X 81.31 X 0.00276 = A�,;,P�'m'b,v"��, E[) 'i/' 928 Sensible Air Sensible CFM ELA pyy i`� FOR � CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,128 E QATF BY EnemvPro 5.1 by EnemySoft User Number. 6712 RunCode: 2015-01-07715.138:15.-1D P -a - 28 of 35 s RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Fleenor Residence 1 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Kitchen/Dining/Office Outdoor Dry Bulb Temperature 112 OF Floor Area 3,856.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dallv Range: 34 °F Opaque Surfaces R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) Wood Door R-21 Wall (W..21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation III" (NE) (SE) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 3,856.01 0.0260 56.0 438.5 0.0690 29.0 24.0 0.5000 29.0 587.0 0.0690 31.0 456.01 0.0690 31.0 447.0 0,0690 30.2 375 14,348 Page Total. Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPn?Stratlnn D 2 D C B A 1 A R Orientation (NE) (NE) (NE) (NE) (NE) (NE) (NE) (NE) (NE) Btu/hr 5,614 877 348 1,256 975 932 I 10,0031 Shaded Area X X X X X X X X X GLF 19.7 22.3 19.7 19.7 19.7 19.7 34.9 19.7 19.7 + + + + + + + + +1 Unshaded Area 39.0 X 60.0 X 39.0 X 62.0 X 108.0 X 35.0 X 50.0 X 35.0 X 12.51 X GLF 30.0 = 34.8 = 30.0 = 30.0 = 30.0 = 30.0 = 47.1 = 30.0 = 1 30.0 = Page Total Btu/hr 0.0 1,169 0.0 Z089 0.0 1,169 0.0 1,858 0.0 3,236 0.0 1,049 0.0 2,356 0.0 1,049 0.0 375 14,348 Internal Gain Btu/hr Occu ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 211.00 X 34 = 6,611 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 51.9771 Latent Gain Occupants 1.0 Occupants x(2,0gJ- IfUh`/"gec:LA QU' . �V Infiltration: 4,771 X 0.87 X 211.00 X 0.00276 = �..,, ,.� ,,wRO BUILDING & SAFETY D �� �E � ��..-� Air Sensible CFM ELA AW r s FOR CONSTRUCTION 01 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Fleenor Residence 7 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Kitchen/Dining/Office Outdoor Dry Bulb Temperature 112 OF Floor Area 3,856.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranae: 34 OF Opaque Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = = = 0.0 19.7 50.0 27.0 0.0 19.7 20.0 27.0 0.0 19.7 17.5 27.0 0.0 19.7 17.5 27.0 0.0 19.7 36.0 27.0 0.0 19.7 81.0 27.0 384.0 22.3 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration E P N N M L 9 K 12 Internal Gain Oripntatinn (SE) (SE) (SE) (SE) (SE) (SM (SIA9 (SIAL (NNS Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 19.7 50.0 27.0 0.0 19.7 20.0 27.0 0.0 19.7 17.5 27.0 0.0 19.7 17.5 27.0 0.0 19.7 36.0 27.0 0.0 19.7 81.0 27.0 384.0 22.3 0.0 31.2 0.0 19.7 72.0 27.0 0.0 22.3 96.0 34.8 Page Total 1.0 Occupants X 230 Btuh/occ. - 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.87 X 211.00 X 34 = Air Sensible CFM ELA AT Btu/hr r 1 0 541 473 473 973 2,190 8,552 1,947 3,342 19.844 Btu/hr I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5l o»I Latent Gain Occupants 1•o Occupants X 2o� tF�iiccO----- LA Q Infiltration: 4,771 X 0.87 X 211.00 X 0.00276 = BUILDING & SAFET Air Sensible CFM ELA AW t P PRO, VE TOTAL HOURLY LATENT HEAT GAIN FOR ROOM i `' k-UiV, IRI 1(` Btu/hr 200 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Fleenor Residence 7 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Kitchen/Dining/Office Outdoor Dry Bulb Temperature 112 OF Floor Area 3,856.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 10 (NKK 0.0 X 22.3 + 27.0 X 34.8 a 940 X + X - X + X - X + X - X + X - X + X - X + X - X + X - X +1 xi - Page Total 940 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 211.00 X 34 = 6,611 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 51,977 Latent Gain Occupants 1.0 Occupants X -p-q� ' I 29,0 gttuh/p� LA Q� IN 210 UILOING &SAFETY Infiltration: 4,771 X 0.87 X 211.00 X 0.00276 = APPROVE E -- 2,4 8 Air Air Sensible CFM ELA AW FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM (_ . 2 08 By EnerqvPro 5.1 by EnerqvSoft User Number- 6712 Run Code: 2015-01-07715:38:15 a 31 o435 C 17A RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Fleenor Residence 7 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Bed 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 433.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) (lM 433.01 X 0.0260 X 56.0 = 630 R-21 Wall (W.21.2x6.16) (NE) 215.0 X 0.0690 X 29.0 = 430 R-21 Wall (W.21.2x6.16) (SE) 216.5 X 0.0690 X 31.0 = 463 R-21 Wall (W.21.2x6.16) (SK0 420.0 X 0.0690 X 31.0 = 898 R-21 Wall (W.21.2x6.16) (NVIO 112.0 X 0.0690 X 30.2 = 234 X X = X X = X X = X X = Page Total 2,656 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr R (NE) 0.0 X 19.7 + 12.5 X 30.0 = 375 R (NE) 0.0 X 19.7 + 12.5 X 30.0 = 375 Q (SE) 0.0 X 19.7 + 7.5 X 27.0 = 203 F (SE) 0.0 X 19.7 + 6.0 X 27.0 = 162 11 (NM 0.0 X 22.3 + 48.0 X 34.8 = 1,671 X + X - X + X - X + X - X + X I - Page Total 2,785 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 23.69 X 34 = 742 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,413 Latent Gain Occupants OF LA 0�, 6� t I. r 1.0 Occupants X 200 / 0 p 0>JIL to occ i�jraG ;;al"ET tl� . Infiltration: 4,771 X 0.87 X 23.69 X Air Sensible CFM ELA ow F -OR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM = 47� Ener Pro 5.1 by EnemySoft User Number: 6712 Run Code: 2015-01-07715.38:15 ID: 0 4 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Fleenor Residence 1lI/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,591.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) (W) 1,591.01 X 0.0260 X 56.0 = 2,316 R-21 Wall (W.21.2x6.16) (NE) 414.0 X 0.0690 X 29.0 = 828 Insulated Garage Door (NE) 144.0 X 0.1061 X 29.0 = 443 R-21 Wall (W.21.2x6.16) (SE) 400.0 X 0.0690 X 31.0 = 856 R-21 Wall (W.21.2x6.16) (SVIO 160.0 X 0.0690 X 31.0 = 342 R-21 Wall (W.21.2x6.16) (NV19 343.0 X 0.0690 X 30.2 = 715 Wood Door (NVI9 24.0 X 0.5000 X 30.2 = 363 Insulated Garage Door (NM 232.0 X 0.1061 X 30.2 = 744 X X = Page Total 6,608 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference.(CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr F (NE) 0.0 X 19.7 + 6.0 X 30.0 = 180 F (NE) 0.0 X 19.7 + 6.0 X 30.0 = 180 F (NW) 0.0 X 19.7 + 6.0 X 30.0 = 180 X + X - X + X - X + X - X + X - X + X - X + X - Page Total 539 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ.= 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 73.31 X 34 = 2,297 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,674 Latent Gain - Rb 1 r Occupants 1.0 Occupants X (3001 °t iuh occ. (A QTA 200 �=: I Infiltration: 4,771 X 0.87 X 73.31 X 0.00276 BUILDING & SAFETY DP 837 APF -'ROVED' Air Sensible CFM ELA DW FOR CONSTRUCTION i TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 037 3ov Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2015-01-07T15:38:15i �. T lD: Page33 f 35 r� �y I RESIDENTIAL ROOM COOLING LOAD SUMMARY I The Fleenor Residence 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,156.0 ft2 Outdoor Wet Bulb Temperature 78 OF indoor Dry Bulb Temperature 78 OF Outdoor Dailv Range: 34 OF R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (SE) (SVt� Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,156.0 0.0260 56.0 321.0 0.0690 29.0 328.0 0.0690 31.0 325.0 0.0690 31.0 350.0 0.0690 30.2 32.0 0.0 15.0 Page Total Fenestratinn AA BB cc DD DD G2 EE G1 EE Orientation (NE) (NE) (NE) (SE) (SE) (SIA9 (SW) (S W) (NKK Shaded Area GLF X 19.7 X 19.7 X 19.7 X 19.7 X 19.7 X 22.3 X 19.7 X 22.3 X 19.7 + + + + + + + + + Unshaded Area GLF X 30.0 X 30.0 X 30.0 X 27.0 X 27.0 X 31.2 X 27.0 X 31.2 X Page Total = = = = = = = = 0.0 35.0 0.0 56.0 0.0 8.0 0.0 6.0 0.01 6.0 0.0 48.0 0.0 15.0 0.0 32.0 0.0 15.0 Btu/hr 1,683 642 702 695 730 4,452 Btu/hr 1,049 1,678 240 162 162 1,500 406 1,000 449 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 63.26 X 34 = 1,982 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,760 Latent Gain Occupants 1.0 Occupants X Infiltration: 4,771 X 0.87 X 63.26 X 0.00276 Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN iyl Mur� .r LA QUI� BUILDING & SAFETY APPR®VEC 200 • w s RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Fleenor Residence 1/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,156.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr EE (NIM 0.01 X 19.7 + 15.0 X 30.0 = 449 X + X - X + X - X + X - X + X - X + X - X + X - X + X - X + X - Page Total 449 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ.= 230 Equipment 0.0 Dwelling Unit X 1,600 Btu - 0 Infiltration: 1.064 X 0.87 X 63.26 X 34 = 1,982 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,760 Latent Gain OF LA 0UIN B& Occupants 10 Occupants X -/ �2ooG Bth/oce. EPT. -oo UIQ & SA��Aixg��• Infiltration: 4,771 X 0.87 X 63.26 X 0.00276 = T'PRO `° 712 Air Sensible CFM ELA AW �CjR CONSTRUCT11-564 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2 i DATE J EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2015-01-07715:38:15 '•--ID: Pa a 35 of 35 Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/7/2015 Electronically Signed at Ca10ERTS.com by George Camarena (Fedderly & Associates) 1/7/2015 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Fleenor Residence Building Type 0 Single Family 0 Addition Alone 0 Multi Family O Existing+ Addition/Alteration Date 1/7/2015 Project Address 80-325 Via Capri, The Hideaway La Quin California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,522 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. © Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area. Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 8,522 Radiant Barrier New Wall Wood Framed R-21 6,748 New Slab Unheated Slab -on -Grade None 8,522 Perim = 784' yp yy e Door Opaque Door None 48 Door Opaque Door None 376 Int --R-8.0 New JAN 0 9 2015 1 I v Ur UA cru FENESTRATION U- e%i'' '` ' t N Orientation Area(ft) =^Factor SHGC Overhang Sidefins Shades Status Left (SE) 30.0 1 0.390 0.39 none none Bug Screen New Rear (SW) 350.0 - 0.390 ,,.0.32,x, none. , ,. —.,r none ,; Bug, Screen%PKVA,,,,, New Right(Nl9t�5e.' �4. 60.0 0.390x ,032;''none' µznnone 1 " ..a�.M ' Bug�Screen,1t. New Front AT)l u' ( )l _,;3965u 032 none_ sir` s,r #" �'_ none;: .Bug Screeny,; �� New Front (NE) x"I , r 60 O rif f; 0.390 ��, 0 39 o e; none Bug Screen r 4' n n tlt,r . z `' .; "e2r c /Vew! Front(NE) ,,s<g700r X0.390 032'x- 20 4 i Frione;.FR� Bu Screen�'� New r" sk '7 t15 i�r` 3 � 9: Front (NE) w.. ,� .:: • � . �,Wi , 50.0 �~ 1 A40 ` 0.38 2 0 none Bug Screen New Left (SE) , ,.' �: 166.5 ; , 0.390 0.32 none none Bug Screen New Rear (SM 384.0 t 0.390 0.39 22.0 none Bug Screen New Right (NM 144.0 % 0.390 0.39 none none Bug Screen New Right (NW) 27.0 0.390 0.39 18.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner. 16.0 SEER Setback New 3 Central Furnace 80% AFUE Split Air ConditlonefIt X1'6:0=SEER Setback New 2 Split Heat Pump 10.00 HSPF Split Heat Purflip B •18.0 SEERSetback New HVAC DISTRIBUTION Location HeatingCooling/Du ��.%VfU, �tt � ct.Location� Com, �_�Rr1Va-lue Status HVAC 1 Ducted Ducted Attic, Celih"aCn' vented 1d'lf�`.. Fo o New HVAC 2,3 & 4 Ducted Ducted Oq tti Bilin Ins, e^ e'd°JCjyr,�-d` 8.0 New HVAC 5 & 6 Ductless / with Fan Ductless / n/ New WATER HEATING Ot . Type Gallons Min. Eff Distri ton Status 1 Instant Gas 1 0.70 All Pipes Ins New 1 Instant Gas 1 0.70 All Pipes Ins New 1 Instant Gas 1 0.70 All Pipes Ins New Energ Pro 5.1 by Energ Soft User Number 6712 RunCode: 2015-01-07715:38:15 ID: Page 1 of 9 Reg: 214-N0026233F-000000000-0000 Registration Date/Time: 2014/04/15 14:24:01 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/7/2015 Electronically Signed at Ca10ERTS.com'by George Camarena (Fedderly & Associates) 1/7/2015 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Fleenor Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family- ❑ Existing+ Addition/Alteration Date 1/7/2015 Project Address 80-325 Via Capri, The Hideaway La Quin California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,522 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ( Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) t Factor SHGC Overhang Sidefins Shades Status Rear (SVI9 80.0 i 0.390 0.39 none none Bug Screen New +-�■.::£�'0l.si1r _�r•� 1P,, ,,:'''�"' /.'id'" �',�f'k"�•x+' �s! if:3�'�. [{*�(`L!k;7(�. tyy ,�!q�[y$�}.T.wr.)jj" ii, •� �'"1trf 1j. {"• £ ..,#fr��'', �.� T?�i."�v �5�. �. !`�n1"X�p�"i4. _�__i,•-( ��-.i,�`'�,~.�i�a".,#is;.["yf'� �if�yy�' ,�ji`',L'�'f'� .r. ... v. A ^+r .1 .!.,�;✓...?+_� f.: r-.rn�y,�n yr ak :: "�..a.. ^-�.;�✓ :�,�, ..-aq;.'-- .-.... i HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duc Location R -Value Status HVAC 7 Ducted Ducted Attica eiling nl s, �e ted 8.0 New WATER HEATING SOH 1-J)-1 o r'�-Q�p .0ty. Type Gallons Min. Eff Distri�iution_,� T Status QCT/ Ener Pro 5.1 by Ener Soft User Number. 6712 RunCode: 2015-01-07715:38:15 ID: Page 2 of 9 Reg: 219-N0026233F-000000000-0000 Registration Date/Time: 2014/04/15 14:24:01 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/7/2015 Electronically Signed at CalCERTS.com by George Camarena (Fedderly & Associates) 1/7/2015 PERFORMANCE CERTIFICATE:. Residential . (Part 2 of 5) CF -1 R Project Name The Fleenor Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan waft draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,010.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 476.0 112 Exposed Slab Floor, 3.500" thick at Master Suite The HVAC System HVAC 2, 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 330.0112 Covered Slab Floor, 3.500" thick at Living/Kitchen/Dining/Office HIGH MASS Design - Verify Thermal Mass: 3,526.0 ft2 Exposed Slab Floor, 3.500" thick at Living/Kitchen/Dining/Office HIGH MASS Design - Verify Thermal Mass: 329.0 f12 Covered Slab Floor, 3.500" thick at Bed 2 HIGH MASS Design - Verify Thermal Mass: 104.0 ft2 Exposed Slab Floor, 3.500" thick at Bed 2 The HVAC System HVAC 5 & 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,591.0 ft2 Exposed Slab Floor, 3.500" thick at Garage 1 & 2 The HVAC System HVAC 7 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se crate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS•Design7'Verify Thermal Mass: 719.0112 Covered Slab -Floor 3.500 thick at Guest Suite 11A A HIGH MASS Design - Verify Thermal -Mass 437:0 ft2 Exposed Slab Floor, 3.500" thick at Guest Suite ?' _ v"r HERS REQUIREDWERIFICATION ' g p ) t �? ":•w.'41�i—'.'• `K R' fl—'eaeL'}� 4C,^ x 'l» 7+*itk Items in,tliis s action require field testing and%orhverification,by;a certifiediHERS{Rater. The -inspectorwmustrecei`ve a complete CF -4R form for each" of,the'measures listed below for final to be given. The Cooling ^System Carrier 24APA 760158CVX1 10 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condense. I The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. t The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA760158CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2, 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2, 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA748158CVX110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 7 incorporates HERS Verified Refrigerant Charge or �Oharge Indicator Display. The HVAC System HVAC 7 incorporates HERS verified Duct Leakage. HERS field verification and diagn, stic testing is required to verify that duct leakage meets the specified criteria. v�l��at1in a^ �r V 00 %�J ''V T '/01V Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2015-01-07T15:38:15 t Page 3 of 9 _J Reg: 219-N0026233F-000000000-0000 Registration Date/Time: 2014/04/15 14:24:01 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/7/2015 Electronically Signed at CalCERTS.com by George Camarena (Fedderly & Associates) 1/7/2015 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name The Fleenor Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. �f". -_ �, l.•. -�1 }F"h� .viL�f. r.� ��f -,t .�+�Y f�r�r�, T' +�f .�� •j'�' a��: �F+����.1;YI �'{:��K ^J�•,�`fr' `y��' �3✓? .: ,j1• a,W� ..`ly, _ _ . #;s HERSIREQUIRED1UERIFICATIONliItems r"�"'� in this section re uire field,testin and/or veation'b a certied',HERS Rater" The'Ins ector must receive a Q - 9 .,� _. y4 ,,;. , - % p com Ieted'CF-4R form for each of the measures listed below for final to -be iven. A.. r F C ' e OA/�� y V+ CN� k-//pN Y Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2015-01-07T15:38:15 ID ----.-Page 4 of 9 -1-.J ' Reg: 219-N0026233F-000000000-0000 Registration Date/Time: 2014/04/15 14:24:01 HERS Provider: CalCERTS, Inc r .S ..r .nr • .� , d ,.. • - _ .. e - {;.lr- -.r; yr-.; a ,•fsJi;�+,� F• �t. �w,i•.. x.. Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/7/2015 Electronically Signed at CalCERTS.com by George Camarena (Fedderly & Associates) 1/7/2015 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name0 Single Family ❑ Addition Alone Date The Fleenor Residence ❑ Multi Family ❑ Existing+Addition/Alteration 777 1/7/2015 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.00 4.44 -0.43 Space Cooling 51.21 39.59 11.63 Fans 10.11 11.99 -1.88 Domestic Hot Water 4.28 3.58 0.70 Pumps 0.00 0.00 0.00 Totals 69.60 59.59 10.01 Percent Better Than Standard: 14.4 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 2,358 577 Fuel Available at Site: Natural Gas (SE) 1,884 197 Raised Floor Area: 0 (SK9 2,599 814 Slab on Grade Area: 8,522 (NKK 2,149 231 Average Ceiling Height: 11.4 Roof 8,522 0 Fenestration Average U -Factor: 0.41 TOTAL: 1,816 Average SHGC: 0.35 Fenestration/CFA Ratio: 21.3% REMARKS Or 4 W. � .'Y � � �4 5 � moi" •'4:^', � �{, Y M • :� .P �..,� .yc� y dpi r'3''�:L. �, �` B :t' t .. %�.� ,',,j���,l��'� ���Td1 f y� -,i ^ o 'ar�-i'�*i'St" � `�: 1,�����"�'%,.f �� ." igaw +.eZ.S.tt ..t..+ -?+yFn,�.��'T"al��' •,� � n f. STATEMENT'OF COMPLIANCE This certificate of compliance'lists the building features and specifications needed to comply with Title 24, Parts".1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 1/7/2015 Address 77-085 Michigan Drive Name' Tim Scott Cit State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Fedderly and Associates Address 38-747 Nopales Road Name Fedderly and Associates City/State/Zip Palm Desert, Ca 92253 Phone (760) 773-0875 Signed License # Date Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2015-01-07715:38:15 ID: Page 5 of 9 Reg: 214-N0026233F-000000000-0000 Registration Date/Time: 2014/04/15 14:24:01 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/7/2015 Electronically Signed at Ca10ERTS.com by George Camarena (Fedderly & Associates) 1/7/2015 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name The Fleenor Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area I Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof -1,4861 0.026 R-38 1 270 0 New 4.2.1-A9 Master Suite Wall 225 0.069 R-21 45 90 New 4.3.1-A6 Master Suite Wall 156 0.069 R-21 135 90 New 4.3.1-A6 Master Suite Wall 424 0.069 R-21 225 90 New 4.3.1-A6 Master Suite Wall 410 0.069 R-21 315 90 New 4.3.1-A6 Master Suite Slab 1,010 0.730 None 0 180 New 4.4.7-A1 Master Suite Slab 476 0.730 None 0 180 New 4.4.7-A1 Master Suite .. Roof 3,856 0.026 R-38 270 0 New 4.2.1-A9 Living Zone Wall 439 0.069 R-21 45 90 New 4.3.1-A6 Living Zone Door 24 0.500 None 90 New 4.5.1-A4 Living Zone Wall 587 0.069 R-21 90 New 4.3.1-A6 Living Zone Wall 456 0.069 R-21 90 New 4.3.1-A6 LivingZone Wall 447 0.069 R-21 N�225 90 New 4.3.1-A6 Living Zone Slab 330 •0.730 None 180 New 4.4.7-A1 Livin Zone Slab 3,526 0.730 None 180 New 4.4.7-A1 Livin Zone Roof 433 0.026 R-38 0 New 4.2.1-A9 jBed 2 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 30.0 0.390 NFRC 0.39 NFRC 135 New Dual Non Metal Tinted Door Master Suite 2 Window 120.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Master Suite 3 Window 6.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Master Suite 4 Window 40.0 0.390 NFRC 0.32 NFRC 225 New Dual Non Metal Tinted Master Suite 5 Window - _ 6.0 0.390 NFRC 0.32 NFRC _ ___-225, New Dual Non Metal Tinted -- Master Master Suite 6 Window; N 10.0 0.390 NFRC o K 0.32 NFRC `syw; 225 NewDual Ncn'Metal,Tinted".j�,, ,'jr: 'Master Suite 7 Window'' 124.0 0.390 1 NFRC:'' 1 ',%41 0.32 'NFRC;.-, !' 315 New ``Y' Dual Non MetahTinted Master Suite 8 Window 39.0 2:0.390 NFRC tali; : 0.32 NFRC:-: 45 New.. `+ Dual Non"Metal Tinted y'ti_ Living Zone - 9 Window 60.0 10.390 NFRCr.,t 0.39 NFRC�vl ski,, 45 New;+ ani Dual Non Metal Tinted Door.*;. Living Zone,; 10 Window ,/ ,139.0 ,1:;0.390 NFRC 4G=1 �,. 0.37 NFRC 1 445 New;c,.'S`rig, Dual Non Metal.TintedLiying,Zohe €� 11 Window 9 ir�� 62.0 'zr, 0.390 NFRC b:1- x.0.32 NFRC,,V. WF.,�#'45 New? '+k' Dual Non Metal Tinted k„K# � w Living Zone'�"o 12 Window 108.0 -0.390 NFRC `t-=- Q -k* 0.32 NFRC ` ' i--45 New Dual Non Metal Tinted Living Zone 13 Window _ 35.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Living Zone 14 _ Window" '50.0 1.040 NFRC 0.38 NFRC 45 New Custom Door Living Zone 15 Window 35.0 0.390 1 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Living Zone 16 Window 12.5 0. 3901 NFRC 1 0.32 NFRC 451 New Dual Non Metal Tinted Living Zone (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 s 5 Bug Screen 0.76 r 6 Bug Screen 0.76 7 Bug Screen 0.76 �li1�f1,... -11 C)" itn,_ 8 Bug Screen 0.76 �� °� vi 114 t; r---.� 01 U 9 Bug Screen 0.76 w. R" t .i k - �` Y OP 10 Bug Screen 0.76 11 Bug Screen 0.76 1 v - 12 Bug Screen 0.76 13 Bug Screen 0.76 10.0 3.5 2.0 .1 2.0 14 Bug Screen 0.76 10.0 5.0 2.0 0.1 B 15 jBug Screen 1 0.76 10.0 3.5 2.0 0.1 2.0 2. 16 jBug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2015-01-07715:38:15 ID:. Page 6 of 9 Reg: 214-N0026233F-000000000-0000 Registration Date/Time: 2014/04/15 14:24:01 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/7/2015 Electronically Siqned at CalCERTS.com by Georae Camarena (Fedderly a A anriatas) 1/7/9n15 CERTIFICATE OF COMPLIANCE: Residential Part 4 of.5 CF -1 R Project Name The Fleenor Residence I Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Wall 215 0.069 R-21 45 90 New 4.3.1-A6 Bed 2 Wall 217 0.069 R-21 135 90 New 4.3.1-A6 Bed 2 Wall 420 0.069 R-21 225 90 New 4.3.1-A6 Bed 2 Wall 112 0.069 R-21 315 90 New 4.3.1-A6 Bed 2 Slab 329 0.730 None 0 180 New 4.4.7-A1 Bed 2 Slab 1041 0.730 None 0 180 New 4.4.7-A1 Bed 2 Roof 1,591 0.026 R-38 270 0 New 4.2.1-A9 Garage 1 & 2 Wall 414 0.069 R-21 45 90 New 4.3.1-A6 Garage 1 & 2 Door 144 0.106 None 8.0 None 45 90 New 4.5.1-A2 Garage 1 & 2 Wall 400 0.069 R-21 135 90 New 4.3.1-A6 Garage 1 & 2 Wall 160 0.069 R-21 225 90 New 4.3.1-A6 Garage 1 & 2 Wall 343 0.069 R-21 315 90 New 4.3.1-A6 Garage 1 & 2 Door 24 0.500 None 315 90 New 4.5.1-A4 Garage 1 & 2 Door 96 0.106 None 8.0 None 315 90 New 4.5.1-A2 Gara e 1 & 2 Door 136 0.106 None 8.0 None 315 90 New 4.5.1-A2 Gara e 1 & 2 Slab 1,5911-0.730 None 01 180 1 New 4.4.7-A1 Garage 1 & 2. FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 50.0 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Living Zone 18 Window 20.0 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Living Zone 19 Window 17.5 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Living Zone 20 Window 17.5 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Living Zone 21 Window_ 36.0 0.390 NFRC, _0.32_ NFRC_._. 135 New .-I.Dual ,Non Metal Tinted _ ... Living Zone 22 Window.. `y'81.0 0.390 NFRC ,,�t ;ri;0.32 NFRCf-:, 2-225 NeWAL;,.J DuaPNon Metal.TfntediPf,.h;„ ;'Living Zone 23 Windows' 384.0 0.390 NFRC'4 rrot0.39 'NFRC ; t.` 225 New�yZ*P',i Dual Non MetaLTinteo Door- " Living Zone 24 25 `�:-.� Living Zone �--- ;Window 72.0- X0.390. NFRCQ- °' 0.32 NFRC46 ; ;:4225 New L.7 Dual Non'Metal Tinted. - Window 96:0 P0.390 NFRCI;a 0.39 NFRC r„ .':1 315 New �ogii Dual Non Metal Tinted DoorA,!; Living;Zone 26 Window J27.0 1, 0.390 NFRC : O 0.39 NFRC 315 'New fi Dual Non Metal Tinted Door, -tet; Living;Zon6Ijtf 27 WindowmAt.:V12.5 , 0.390 NFRCir� ft,'0.32 NFRC': *N ---a,45 New X1 Dual Non Metal Tintedl >_2 Bed'2RFP-I %hft 28 Window ' " 12.5 "0.390 NFRC'= 0.32 NFRC'{'-`''x-45 New Dual Non Metal Tinted' '- Bed 2 29 Window 7.5 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Bed 2 , 30 , Window % x, 6.0 0.390 NFRC 0.32 NFRC 135 New Dual Non Metal Tinted Bed 2 31 Window 48.0 0.390 NFRC 0.39 NFRC 315 New Dual Non Metal Tinted Door Bed 2 32 Window 6.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Garage 1 & 2 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade T H e SHGC t Wd Ove hang Left Fin Len H t LExt REM Dist Len Right Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 12.0 32.0 22.00 1 24 Bug Screen 0.76 25 Bug Screen 0.76 �"'� �f� ,q. r,„ 26 Bug Screen 0.76 9.0 3.0 18.0 0.1 18;0, r--%1,8.0,- "^ -C n r 27 Bug Screen 0.76>r-- 28 Bug Screen 0.76 1z L 29 Bug Screen 0.76 CT 30 Bug Screen 0.76 p 31 JBug Screen 0.76 32 JBug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number. 6712 Run Code: 2015-01-07715:38:15 ID: Page 7 of 9 Reg: 214-N0026233F-000000000-0000 Registration Date/Time: 2014/04/15 14:24:01 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/7/2015 Electronically Signed at CalCERTS.com by Georqe Camarena (Fedderly & Associates) 1/7/2015 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name The Fleenor Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,156 0.026 R-38 270 0 New 4.2.1-A9 Guest Suite Wall 321 0.069 R-21 45 90 New 4.3.1-A6 Guest Suite Wall 328 0.069 R-21 135 90 New 4.3.1-A6 Guest Suite Wall 325 0.069 R-21 225 90 New 4.3.1-A6 Guest Suite Wall 350 0.069 R-21 315 90 New 4.3.1-A6 Guest Suite Slab 719 0.730 None 0 180 New 4.4.7-A1 Guest Suite Slab 437 0.730 None 0 180 New 4.4.7-A1 Guest Suite FENESTRATION SURFACE DETAILS ID T e Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 6.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Garage 1 & 2 34 Window 6.0 0.390 NFRC 0.32 NFRC 315 New Dual Non Metal Tinted Garage 1 & 2 35 Window - - 35.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Guest Suite 36 Window 56.0 0.390 NFRC 0.32 NFRC 45 New Dual Non Metal Tinted Guest Suite 37 . Window_ p _ _8.0 0.390 NFRC _0.32 NFRC,--,45 New ,:- Dual Non Metal Tinted Guest Suite 38 Wind6w--1 .' %1.6.0 0.390 NFRC ,,r ) 0.32 NFRC --v�--135 New;%4z'1 Dual'Non Metaf,Tihtedr�#";.x �f"Guest Suite 39 Wfndowx "6.0 6.0 0.390 NFRC..I, FS,'0.32 'NFRC:, " r- 135 New;:y' - i Dual Non Metal.,Tirited � e"FZ_ y Guest Suite 40 •Window 48.0 r 0.390, NFRCe: - ' 0.39 NFRC;° X225 New -10f Dual Non`Metal Tinted`D_ oor�;, Guest Suite r- - •- . 41 Window 15:0 X0.390 NFRC r;. r; 0.32 NFRC;tf ' fir: 225New ";- Dual Non Metal Tinted _.;ws Guest Suite 42 Window 4)32.0 32.0 ,e 0.390 NFRC ;.4f 0.39 NFRC r ,225 'New; Z. Dual Non Metal:Tinted Door -414 GUest,Suitel~'O 43 Windows. •'..,V.15.0 :;:0.390 NFRC a; --46.32 NFRC:8315 Newt %C4 Duet Non Metal Tinted 1 Guest Sditellft 44 Window' 15.0 '0.390 NFRC ,r.. �-cri0.32 NFRC '!"5315 New Dual Non Metal Tinted Guest Suite (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Ove hang Left Fin Right Fin Exterior Shade Type SHGC -Hot Wd Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 1T, 41 Bug Screen 0.76 1 n E r 42 Bug Screen 0.76 Oun #A,,,` 1�� n1 1, , 43 Bug Screen 0.76 " v u Yt .0 r 'V I 44 Bug Screen 0.76 A ti Y 10 nrA 9- 1 IiO _ By Ener Pro 5.1 by Ener Soft User Number- 6712 RunCode: 2015-01-07715:38:15 ID: Pa e 8 of 9 Reg: 214-N0026233F-000000000-0000 Registration Date/Time: 2014/04/15 14:24:01 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/7/2015 Electronically Signed at CalCERTS.com by George Camarena (Fedderly & Associates) 1/7/2015 CERTIFICATE OF COMPLIANCE: Residential , (Part 5 of 5) CF -1 R Project Name The Fleenor Residence Building Type 2 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/7/2015 BUILDING ZONE INFORMATION' Floor Area System Name Zone Name New Existin Altered • Removed Volume Year Built HVAC 1 Master Suite 1,486 16,346 HVAC Z 3 & 4 Living/Kitchen/Dining/Office 3,856 48,586 Bed 2 433 4,330 HVAC 5 & 6 Garage 1 & 2 1,591 15,910 HVAC 7 Guest Suite 1,156 11,560 Totals 1 8,5221 01 01 0 HVAC SYSTEMS System Name Ot ' Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 j Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC Z 3 & 4 3 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 5 & 6-oVw*4%* 2 ,_ Split Heat Pump".. 10.00 HSPF Split Heat -Pum T18:0 -SEER, Setback New HVAC 7 /-Yj ,�' V91 1 Furnace FI'4 86%S littAir.Conditionerz x16.0 SEER SeytbackE New YYii yC��enntwr�a/ yAFUE )t All' I HVAC; DISTRIBUTION A*i': •+"!s: •f. ^fir�y� r+,i r." �Duct�`* Ducts Sys em Name -HHeatin Coolin Duct Location ` R -Value Tested? Status HVAC 1 _ ,,.-.: Ducted Ducted Attic, Ceiling Ins, vented' 8.0 0 New HVAC 2,-3 & 4 `' Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New HVAC 5 & 6 Ductless/ with Fan Ductless n/a n/a ❑ New HVAC 7 Ducted Ducted Attic, Ceiling Ins, vented 8.01 0 New WATER HEATING SYSTEMS S stem Name Ot . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White #IGI-180R 1 Instant Gas All Pipes Ins 180,000 1 0.70 n/a n/a New Bradford White #IGI-180R 1 Instant Gas 1A11Pipes1ns 1 180,0001 1 1 0.70 n/a n/a I New Bradford White #IGI-180RI 1 Instant Gas All Pipes Ins 80,0001 1 1 0.70 1 n/a n/a INew MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING , Control Hot Water Piping Length ft � o i� Q — CEry I 6Ulrr (jr�r S stem Name �$ I„P_ipe,���P+p cLeri fh�;-Diameter Insul. hick. Ot . HP Plenum Outside Buried 13 ❑ ❑ ❑ Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2015-01-07715:38:15 ID: I Page 9 of 9 Reg: 219-N0026233F-000000000-0000 Registration Date/Time: 2014/04/15 14:24:01 HERS Provider: CalCERTS, Inc