14-0069 (SFD)P.O. BOX 1504
78-495 CALL•E TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: 14'-000:0-0-0.69 _ Owner:
Property Address: 8'03°0:5 VIA CAPRI MCCREARY RESIDENCE
APN: 772-440-052- - - 40101 MONTEREY AVE. #B1\214
Application description: DWELLING - SINGLE FAMILY DETACHED RANCHO MIRAGE, CA 92270
Property Zoning: LOW DENSITY RESIDENTIAL (760) 773-6633
Application valuation: 495305
Applicant: - Architect or Engineer:
------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with
Section 70001 of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 533670
Date':Co_ n�� tra or.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of erjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the.structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
-and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 _ 1 lam exempt under Sec. B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/29/14
Contractor:
SUNROSE CORPORATION
40101 MONTEREY AVE STE
RANCHO MIRAGE, CA 92270
_
B1-2
�� _ d#
(760)773-6633
Lic. No.. 533670
+(
I CIV, OF 6.A ri UINTA
----------------------------'-_-_--,;wr.Itp , -----
WORKER'S COMPENSATION DE 'CXWnO
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 1948056-2014
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should became subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with those provisions.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS (5100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to center upon the above-mentioned property for inspection purposes.
Date: F; Signature (Applicant or Agent): _
Application Number . . . . . 14-00000069
------ Structure Information NEW SFD
-----
Other struct info . .
. . . CODE EDITION
2013
# BEDROOMS
5.00
FIRE SPRINKLERS
13-D 6340
GARAGE SQ FTG
1046.00
V
PATIO SQ FTG
2727.00
NUMBER OF UNITS
1.00
1ST FLOOR SQUARE FOOTAGE
4831.00
----------------------------------------------------------------------------
2ND FLOOR SQUARE FOOTAGE
463.00
Permit
. . .
BUILDING 2013
Additional
desc . .
Permit Fee
. . . .
739.19 Plan Check Fee
00
Issue Date
. . . .
Valuation . .
. . 495305
Expiration
Date
10/26/14
Qty Unit Charge
Per
Extension
BASE FEE
573.43
296.00
----------------------------------------------------------------------------
.5600
THOU BLDG $200,001-$1M
165.76
Permit
. . .
ELECTRICAL 2013
Additional
desc . .
Permit Fee
. . . .
263.62 Plan Check Fee
.00
Issue Date
. . . .
Valuation . .
. . 0
Expiration
Date . .
10/26/14
Qty Unit Charge
Per
Extension
.00
23.8300
LS ELEC FIXTURES, FIRST 20
.00
1.00
23.8300
EA ELEC SERVICES
23.83
1.00
23.8300
EA ELEC TEMP POWER POLES
23.83
1.00
143.0000
LS ELEC NEW RES, FIRST 1 KSF
143.00
6.00
----------------------------------------------------------------------------
12.1600
EA ELEC NEW RES, ADD'L 1 KSF
72.96
Permit
. . . MECHANICAL 2013
Additional
desc . .
Permit Fee
583.96 Plan Check Fee
.00
Issue Date
. . . .
Valuation
0
Expiration
Date . .
10/26/14
Qty Unit Charge
Per
Extension
6.00
35.7500
EA MECH FURNACE
214.50
1.00
11.9200
EA MECH APPL REP/ALT
11.92
6.00
35.7500
EA MECH CONDENSER/COMP
214.50
10.00
11.9200
EA MECH VENT FAN
119:20
LQPERMIT
Application Number . . . . . 14-00000069
Permit . . . MECHANICAL 2013'
Qty Unit Charge Per
Extension
2.00
------------------------------------
11.9200 EA MECH EXHAUST HOOD
--------------------------=-------------
23.84
Permit
. . . PLUMBING 2013
Additional desc
.
Permit Fee .
. . . 429.11 Plan Check Fee
.00
Issue Date .
. . . Valuation . . .
. •0
Expiration.Date
10/26/14
Qty Unit
Charge Per
Extension
29.00
11.9200 EA PLBG FIXTURE/TRAP
345.68
1.00
11.9200 EA PLBG BUILDING SEWER
11.92
2.00
11.9200 EA PLBG WATER HEATER/VENT
23.84
1.00
11.9200 EA PLBG WATER INST/ALT/REP
,11.92
1.00
35.7500 LS PLBG GAS SYS, 5+ OUTLETS
35.75
----------------------------------------------------------------------------
Special Notes
and Comments
NWE SFD 5294
SQ. WITH 2727 SQ. FT. PATIO
DECK AND 1046
SQ.FT.GARAGE.HOME IS FIRE
SPRINKLED PER
2013 CRC CODES. THIS
PERMIT DOES NOT INCLUDE POOL SPA, BLOCK
WALLS OR DRIVEWAY APPROACH, BBQ, OR
FIRE -PIT
February 13,
2014 1:49:40 PM jjohnson.
----------------------------------------------------------------------------
Other Fees .
. . . . . . . . ART IN PUBLIC PLACES -RES
738.26
BLDG STDS ADMIN (SB1473)
20.•00
DIF COMMUNITY CENTERS -RES
129.00
DIF CIVIC CENTER - RES
942.00
DIF FIRE PROTECTION -RES
433.00
DIF LIBRARIES - RES
344.00
PLAN CHECK, ELECTRICAL
105.85
DIF PARK MAINT FAC - RES
40.00
PLAN CHECK, MECHANICAL
347.97
PLAN CHECK, SFD GRADING
143.00
PLAN CHECK, PLUMBING
407.65
DIF PARKS/REC - RES
2048.00
BLDG PC 200K -1M
1590.54
.STRONG MOTION (SMI) - RES
49.53
TUMF: RESIDENTIAL
1837.44
DIF STREET MAINT FAC -RES
116.00
DIF TRANSPORTATION - RES
2842.00
Fee summary
-----------------
Charged Paid Credited
----------------------------------------
Due
LQPERMIT
Application Number . . . . . 14-00000069
Permit Fee Total 2015.88 .00
Plan Check Total .00 .00
Other Fee Total' 12134.24 1250.00
Grand Total 14150.12 1250.00
LQPERMIT
00 2015.88
00 1.00
00 10884.24
00 12900.12
Buildin(
Addres
Owner,
eh; p
Mailing
Addres
o - 30s -
V Ire
Ti4 4 4 a"
P.O. BOX 1504 APPLICATION ONLY
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
1� c6c_ zqG ceea r
s yo -10 ►o-�yd3t -2 /1/
Zip Tel.
P�Id Ci 2- 760 -773
;tor
l.Nif�ie �r�d%2r�Da1
Zip Tel.
oA -c e �76e)-723-663'
& Classif. 33 (, D Lic. #
Arch., Engr.,
Designer
Address Tel.
City r Zip State
lV'l//n G! Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000)
of Division 3 of the Business and Professions Code, and my license is in full force and effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
(Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct,
alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for
such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac-
tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any
violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
not more than five hundred dollars ($500).
❑I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not appy to an owner of property who builds or
improves thereon and who does such work himself or through his own employees, provided that
such improvements are not intended or offered for sale. It, however, the building or improvement
is sold within one year of completion, the owner -builder will have the burden of proving that he did
not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the
project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not appy
to an owner of property who builds or improves thereon, and who contracts for such projects with
a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not employ
any person in any manner so as to become subject to Workers' Compensation Laws of California.
Date Owner
NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for
which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
BUILDING: TYPE CONST. OCC. GRP.
A.P. Number -777-- 160 06_3
Legal Description tot t `t —1,5-
Project
5Project Description eot,7 ?)4'1k.--74- t4• 51--d
Sq. Ft. ��� �� No. No. Dw.
Size i Stories 2-- Units
New k Add ❑ Alter ❑ Repair ❑ . Demolition ❑
IEstimated Valuation /. r
PERMIT AMOUNT
Plan Chk. Dep. ,
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
67
TOTAL Q
CONTACT INFORMATION
NAME:
PHONE:
ZONE: BY:
Minimum Setback Distances:
Front Setback
Side
Side
FINAL DATE
Issued by:
Validated by:
Validation:
YELLOW = APPLICANT
PINK = FINANCE
Coachella Vill`ey Unified School District This Box For District Use only
83-7.33 Avenue 55, Thermal; CA 92274 DEVELOPER FEES PAID
(760) 398-5909 — Fax (760) 398-1224
AREA: ..
AMOUNT .. ..
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMWIND. AMOUNT:
DATE:
RECEIPT:
CHECK- #: -
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: McCreary Residence @ The Hideaway Date: Apri125, 2014 .
Owner's Name: Phone No. 7607773-6633
Project Address: 80-305 Via Capri, La Quinta, CA 92253 '
Project Description: Single Family Dwelling Unit
APN: 777-100-053 Tract #: Lot #'s:
Type of Development: Residential . XX Commercial Industrial
Total Square Feet of Building Area: 5,294 SQ FT
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of.perjury and further represents that he/she is authorized to sign on behalf of the owner/developer..
Dated: Signature:..i�—x
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH'ONE OF THE FOLLOWING: (CIRCLE ONE) .
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Number of Sq.Ft. 5,294
Amount per Sq.Ft. $3.20
Amount Collected. $16,940.80
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by: Leticia Torres, Facilities Analyst Signa / re:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF AND�_ATEMT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires t t th' istrict provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest periodin, regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020'of the Government code. Additionally, the amount ofthe fees imposed is as herein set forth, whether payable at this
time or in whole or in part. prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.'
MV:c/mydocs/devfees/certificate of compliance form updated 3-2007 11/2010
Documents pmlded by Data7ree LLC On ft's proprietary Imaging and deDdery system. Copyright 2003. All rights reserved.
RECPRDING REQUESTED BY:
LAWYERS -1 V LE
Lawyers Title
WHEN RECORDED MAIL DOCUMENT AND
TAX STATEMENT TO:
Charles J. McCreary, Trustee
2480 St. Laurent Place
Frisco, TX 75034
APN: 777-100-053-4
TITLE ORDER NO.: 613690616
DOC # 2013-0099681
02/28/2013 08:00 AM Fees: $21.00
Page 1 of 3 Doc T Tax Paid
Recorded in Official Records
County of Riverside
Larry W. Ward
Assessor, County Clerk & Recorder
"This document was electronically submitted
to the County of Riverside for recording—
Receipted by: CTOLOSSA
U ( 34 wl 0L* I to THIS SPACE FOR RECORDER'S USE ONLY
--tf?,(a 0 ZA - ( to0 GRANT DEED
The undersigned Grantor(s) declare that the DOCUMENTARY TRANSFER TAX IS:
$ 473.00 County
XX computed on the full value of the interest of property conveyed, or
—computed on the full value less the value of liens or encumbrances remaining thereon at the time of sale.
OR transfer is EXEMPT from tax for the following reason
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Daniel J. Freimuth and Colleen M.
Freimuth, Co -Trustees of The Freimuth Family Trust Dated June 21, 1999
HEREBY GRANT(S) to Charles J. McCreary, as Trustee of The Charles J. McCreary Management Trust UTD December 18,
2012
All that real property situated in the City of La Quinta, County of Riverside, State of California, described as;
Lots 14 & 15 of Amended Tract 29894-2, more completely described per Exhibit "A" attached hereto and made a part
hereof.
Commonly Known As_80305-Via Capri,_La.Quinta, CA_92253
Dated: February 5, 2013
STATE OF CALIFORNIA }
COUNTY OF C9Yta!:w 1
On __ Z\ -t \ �O t3 , before me,
"A- L Aqy"'f , a Notary Public
personally appeared fVaj4ct -X •=Neirtw�4L�
Ar CQ\tetK AA- 4=✓ a %VMv ACA,
who proved to me on the basis of satisfactory evidence to be the
personto whose namepj is/41'0 subscribed to the within
instrument and acknowledged to me that he/shel By executed
the same in his/hedj�t+ authorized capacity(VO, and that by
his/heqgtQPsignaturete on the instrument the persori5� or the
entity upon behalf of which the person4s),acted, executed the
instrument. Cv�
I certify under PENALTY OF PERJURY under the laws of the
State of California that the foregoing paragraph is true and
correct.
WITNESS my hand and official seal.
Signature ka
Mail tax statements to
Return address as shown above
The Friemuth Family Trust June 21, 1999
M.LOCEY
Commieslon / 1864451
a Notary Public - California =
Z Orange County
M Comm. E ices Oct 7, 2013
(SEAL)
0
Documents provided by DataTree LLC vla trs proprietary Imaging antl delNery system. Copyright 2003, All rights reserved.
DOC #2013-0099681 Page 2 of 3 02/28/2013 08:00 AM
GOVERNMENT CODE 27361.7
I CERTIFY UNDER PENALTY OF PERJURY THAT THE NOTARY SEAL
ON THE DOCUMENT TO WHICH THIS STATEMENT IS ATTACHED
READS AS FOLLOWS:
NAME OF NOTARY: M. Lacey
COMMISSION NO: 1864451
PLACE OF EXECUTION: Orange
DATE COMMISSION EXPIRES: 10-7-13
MANUFACTURE /V R NO: NNA 1
SIGNATURE: DATE: Z _a l? -/3
uuunnenu p—meo oy uam i ree Lu: via its proprietary Imaging and deWery system. Copyright 4003, All rights reserved.
DOC #2013-0099681 Page 3 of 3 02/28/2013 08:00 AM
EXHIBIT "Art
THE LAND REFERRED TO HEREIN IS SITUATED IN THE COUNTY OF RIVERSIDE, STATE OF
CALIFORNIA, AND IS DESCRIBED AS FOLLOWS:
PARCEL 1:
LOTS 14 AND 15 OF AMENDED TRACT NO. 29894-2, IN THE CITY OF LA QUINTA, COUNTY OF
RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 327, PAGES 56 THROUGH
88, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY AND
SHOWN ON GRANT DEED RECORDED APRIL 1, 2003 AS INSTRUMENT NO. 2003-260913 OF
OFFICIAL RECORDS,
GRANT DEED REFLECTS PARCEL MERGER NO. 2003-401, AS APPROVED BY THE CITY OF LA
QUINTA.
EXCEPTING THEREFROM INTEREST IN ALL WATER, MINERALS, OIL, GAS, PETROLEUM, OTHER
HYDROCARBON SUBSTANCES AND ALL GEOTHERMAL ENERGY SOURCES IN OR UNDER SAID LAND
OR WHICH MAY BE PRODUCED FROM SAID LAND.
PARCEL 2:
NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE,
REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION RECORDED ON
DECEMBER 13, 2002, AS INSTRUMENT NO. 2002-745939, OF OFFICIAL RECORDS.
ASSESSOR'S PARCEL NUMBER: 777-100-053-4
April 7, 2014
Mr. Charles McCreary
2480 St. Laurant Place
Frisco, TX 75034
Re: Lot 14-15 at 80305 Via Capri
Final Working Drawings #2
Dear Mr. McCreary,
The Hideaway Design Review Committee (DRC) reviewed the revised final working drawings at their
April 1, 2014 meeting. The project was approved to start construction; however, the following comments
must be addressed prior to the request for setback observation at the lot.
1. Some of the required architectural detailing was still missing from the plan submittal (ex.
wrought iron rails, stucco recesses, etc.): In addition, some of the details were not keyed in as
required. Please provide all appropriate detailing and proper call -outs.
2. The chimney cap detail appears small for the architectural design presented and may not work
properly with the tile roofing proposed. Please review this detail and modify as necessary.
3. A smooth transition is required with the landscape at the adjacent lot (southwest side).
4.' Bougainvillea "Torch Glow" cannot be maintained in an aesthetically pleasing way at a
maximum height of three feet. The committee recommends the use of a plant that can be
maintained appropriately at 3' as required in the rear yard view corridors.
5. Sheet L-5 shows an entry wall and pot elevations but no construction details were provided.
Please contact Brook Marshall at 760-219-8057 or, by email at DRCFacilitator@gmail.com with any
questions regarding this review or to schedule your Pre -Construction Meeting once a Building Permit has
been obtained.
Sincerely,
The Hideaway Design Review Committee
cc: Andy Suzuki
GM Future Designs
Mike Tuvell
DRC File
AERO ENERGY
TITLE 24 CALCULATIONS
15434 SHELTON DRIVE
LAKE MATHEWS,.CA., 92570
951-776-4140
Date: 14-14
OWNER: MCCREARY RESIDENCE
VIA
A
LA QUINTA, CA 92253
LRECEIVED
A
PROJECT; CUSTOM RESIDENCE
JAN 2 3` 2014
80305 VIA CAPRI
THE HIDEAWAY — LOTS 14/15
CITY OF LA QUINTA
LA QUINTA, CA. ^',
COMMUNITY DEVELOPMENT
** 2008 ENERGY STANDARDS **
STATEMENT OF COMPLIANCE.
The energy conservation standards for new residential buildings as set forth in Title24, Part 2, Chapter 2-53;
and Title 20,, Chapter 2, Subchapter 4, article 1, of the California Administrative Code, have been
Reviewed. This design conforms to all requirements as they apply in Climate Zone 15 using Micropas 8,
Version 8.11, a California Energy Commission approved computer performance program for the 2008
Energy Standards.
PREPARED BY:
:�t0(14-
TERRY M. STATUM
C.E.A. #RO8-07-269
C,E.P.E. #R08-99-1651,
'L �F� oI s Q
Vjj1nIT
FOR P AFE�, DEP r A.
UCT/0N
mos _aYi i
SA-
0
n
�J
** SUMMARY SHEET **
Proiect: McCreary Residence — 80305 Via Capri, La Quinta, Ca. Zone: 15
Custom Residence
Wall Insulation: R-19 in 2x6 Exterior Walls and interior of double walls
Ceiling Insulation: R-30
Radiant Foil Barrier: IS Required
Raised Floor Insulation: R-19 over Garage
Slab Edge Insulation: None
Glazing Type: All glass is DUAL PANE with Low -E Glass. (See Notes)
Minimum Furnace AFUE: 80% AFUE for Main House
7.7 HSPF for Studio
Minimum Heating Capacity: Main House = 111,822 Btu/Hr
Studio = 7,685 Btu/Hr
Minimum A/C SEER: Main House = 14.0 SEER / 12.0 EER
Studio = 13.0 SEER
A/C Tonnage: Main House = Min.Sens.= 88,345 Btu/Hr (A/C Size By Mech. Contractor)
Studio = Min.Sens. = 5,019 Btu/Hr (A/C Size by Mech. Contractor)
Duct Insulation: R-6.0 For Ducts & Plenums in Unconditioned Spaces
(Main House Duct Leakage Test IS Required, Not Studio)
Note(s): 1) See CF -1 R for Main House required HERS Measures.
2) All windows and glass doors (except Weiland) can have clad frames with a
weighted average NFRC U -factor of .36 or less and a weighted average
NFRC SHGC of .30 or less with Low -E glass.
3) Weiland Doors weighted average NFRC U -Factor of .45 and a weighted
average NFRC SHGC of .30.
4) Water Heaters Minimum Energy Factor
Temp. control (on one unit only).
CWY Recirc. Pump & Time
BU p N F LA C�UINT
G & SAFETY DEPT.
FpR ��®VSD
ONSTRUCT/ON
DATE
- By
Continuous Ventilation Calculation
CFA =100 + 7.5 (# of Bedrooms +1) = Ventilation Rate (Min. CFM @ .25" W.C.)
McCreary Residence, 80305 Via Capri, La Quinta, Ca.
Main House 5,034 + 100 + 7.5 (4 + 1) = 50.34 + 37.5 = 87.84 Min. CFM
Studio 260 =100 + 7.5 (1+1) = 2.6 + 15.0 =17.6 Min. CFM
Studio Fan Selection:
Broan #SSQTXE080 (or Equal) (One Required)
55 CFM @.25" W.C.
.3 Sones
Ventilation Exhaust Duct Size:
6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual)
No Limit on Duct Length
• Main House Fan Selection:
Broan #SSQTXE110 (or Equal) (One Required)
90 CFM @.25" W.C.
.7 Sones
•
Ventilation Exhaust Duct Size:
6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual)
125' Max. Length Less 15' for each elbow
CITY OF
BUILDING & LA QUI NTA
S,gPETpEPT.
APPRo��®
FOR CONS jRUCi7pN
rqr�-� ay
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 1
------- -------------------------------------------------------
• Project Title . McCreary Residence Date01/06/1413_11_41
Project Address........ 80305 Via Capri ******---------------------
-- -
La Quinta, Ca. 92253 *v8.l*
Documentation Author... Terry Statum ****** I Building Permit # I
Aero Energy I I
15434 Shelton Drive I Plan Check Date I
Lake Mathews, CA 92570 I I
951-776-4140 I Field Check Date I
Climate Zone..... ..... 15 ---------------------
Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r01)
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R
User#-MP1751 User -Aero Energy Run -McCreary Residence I
-------------------------------------------------------------------------------
•
•
----------------------------
----------------------------
MICROPAS8 ENERGY USE SUMMARY
= Energy Use Standard Proposed Compliance Percent =
(kTDV/sf-yr) Design Design Margin Improvement =
- ----------------------- ---------- ---------- ___w -------- ----------- _
= Space Heating.......... 6.48 8.18 -1.70 -26.2% -
= Space Cooling.......... 89.71 83.21 6.50 7.2% _
Ventilation Fans....... 0.56 0.56 0.00. 0.0% _
= Water Heating.......... 6.49 8.15 -1.66 -25.6% _
Rro, Totals
103.24
103 2�.4c.fva i 5,•
t e.1r4 a vy;..
3.0% 0 10
V Y,R[
B 1 g
colfiplj ith �cmp�r P
MEL '* ylerifica `ol4Req}or G lean
__J------==.�_____� ----------- -- -= --
-- ------
HERS Verification..........
Conditioned Floor Area.....
Building Type ..............
Construction Type ..........
Natural Gas at Site .......
Building Front Orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U -factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Required
5294 sf
Single Family Detached
New
Yes
Front Facing 315 deg (NW)
1
2
FullYear
Slab On Grade
2
67983 cf
4831 sf
25 % of floor area
0.39 Btu/hr-sf-F
0.3
12.8 ft
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014
CITY OF
�q ���P�BLILDING & D
A ORD
ROVE®
FOR CONSTRUCTION
DATE gY
, Inc
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2
•
Project -Title .......... McCreary -Residence
--------------Date,_O1/06/14-13_11_41
MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R
User#-MP1751 User -Aero Energy Run -McCreary Residence
-------------------------------------------------------------------------------
BUILDING ZONE INFORMATION
Floor # of # of Cond- Thermo- Vent Vent Verified
Area Volume Dwell Peop- it- stat Height Area Leakage or
Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap
-------------- ----- ------ ----- ----- ------------- ----- ------- ----------
HOUSE
Residence 5034 65291 0.95 5.7 Yes Setback 2.0 Standard No
STUDIO
Residence 260 2692 0.05 0.2 Yes Setback 2.0 Standard No
ATTIC AND ROOF DETAILS
----------------------
Frame R- R -
Roof Roof Re- Emiss- Frame Spac- Value Value Vent
Mass Rise flect- ivity Depth ing Above Below Area Vent
Roof Type (lb/sqft) ance (in.) (in.) Deck Deck Ratio High
----------- --------- ---- ------ ------ ----- ----- ------ ------ ------ ----
HOUSE
Tile Heavy 3:12 0.10 0.85 3.5 24 oc 0.00 0.00 1/300 0.00
STUDIO
Tile Heavy 3:12-10-10„ 0 8�_ 24,.oc 0,..Q0 .0..00 1/300 0.00
J ,..,' .`? � m"-:, � rw ' _A4_',Pk_
:.� • y F0�AQUE SUC cs ��` sr`'
0.
U_eat F' r dear Anpe
fac;` it n�iis`JA4 y o t��iaijn/
"c'r R�# ?�it�`bx� yam` • Y eri
Sur fa":.ems Typ..bn4r�6m
HOUSE
1 Wall Wood 230 0.071 19 0 315 90 Yes 4.3.1 A23 Front 2x6 Wall
2 Wall Wood 1230 0.071 19 0 315 90 Yes 4..3.1 A23 Front Dbl.Wall
4 Wall Wood 326 0.071 19 0 315 90 No 4.3.1 A23 Gar. 2x6 Wall
5 Wall Wood 688 0.071 19 0 45 90 Yes 4.3.1 A23 Left 2x6 Wall
6 Wall Wood 1135 0.071 19 0 45 90 Yes 4.3.1 A23 Left Dbl.Wall
8 Wall Wood 590 0.071 19 0 135 90 Yes 4.3.1 A23 Back 2x6 Wall
9 Wall Wood 1244 0.071 19 0 135 90 Yes 4.3.1 A23 Back Dbl.Wall
11 Wall Wood 938 0.071 19 0 225 90 Yes 4.3.1 A23 Right 2x6 Wall
12 Wall Wood 867 0.071 19 0 225 90 Yes 4.3.1 A23 Right Dbl.Wall
14 Wall Wood 110 0.071 19 0 225 90 No 4.3.1 A23 Gar. 2x6 Wall
15 AtticRad Wood 4208 0.031 30 0 n/a 0 Yes 4.2.1 A20 Vented Attic
17 Roof Rad Wood 365 0.032 30 0 45 27 Yes 4.2.1 A8 Vaulted Roof
18 RoofRad• Wood 365 0.032 '30 0 225 27 Yes 4.2.1 A8 Vaulted Roof
19 F1oorExt Wood 357 0.048 19 0 n/a 0 No 4.4.2 A4 Over Garage
20 Door Wood 24 0.500 0 0 315 90 Yes 4.5.1 A4 Bed.3 Door
21 Door Wood 48 0.500 0 0 315 90 Yes 4.5.1 A4 Bed.4 Door
22 Door Wood 24 0.500 0 0 31.5 90 No '4.5.1 A4 Garage Door
STUDIO
3 Wall Wood 156 0.071 19 0 315-0�T90 Yes 4'..3�; 1, �A20IN ro t 2x6 Wall
7 Wall Wood 108 0.071 19 0 4f5,UIL90,1pFo 4; 3.1__A 3 G r •x6 Wall
•� 'Datr-t I Y2 DEPT.
,ROVE®
FOR CONSTRUCTION
•DATE
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc
," ..
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-iR Page 3
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
•
Project -Title .......... -McCreary -Residence
--------------Date__O1/06/14-13_11_41
-------------
MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15SO8 Program -FORM CF -1R
User#-MP1751 User -Aero Energy Run -McCreary Residence
-------------------------------------------------------------------------------
•
0
OPAQUE SURFACES
U- Sheath- Solar Appendix
Frame Area fact- Cavity ing .Act Gains JA4 Location/
Surface Type (sf) or R-val R-val Azm Tilt Reference Comments
------------ ----- ---- ----- ----- ----- --- ---- --- --------- --------------
10 Wall Wood 152 0.071 19 0 135 90 Yes 4.3.1 A23 Back 2x6 Wall
13 Wall Wood 154 0.071 19 0 225 90 Yes 4.3.1 A23 Right 2x6 Wall
16 AtticRad Wood 260 0.031 30 0 n/a 0 Yes 4.2.1 A20 Vented Attic
PERIMETER LOSSES
----------------
Appendix
Length F2 Insul Solar JA4 Location/
Surface (ft) Factor R-val Gains Reference Comments
------------ -------------------------- -------------- ---------------------
HOUSE
23 S1abEdge 87 0.730 R-0/Oin No 4.4.7 Al Exposed edge
24 SlabEdge 15 0.730 R-0/Oin No 4.4.7 Al Exposed edge
25 S1abEdge 349 0.730 R-0/Oin No 4.4.7 Al Covered edge
26 S1abEdge 58 0.730 R-0/Oin No 4.4.7 Al Covered edge
Or
HO'u�r,
1 Wind Front
2 Wind Front
3 Door Front
4 Wind Front
5 Door Front
6 Wind Front
7 Door Front
8 Wind Front
9 Wind Front
10 Wind Front
11 Wind Front
12 Wind Front
13 Door Left
14 Wind Left
15 Wind Left
16 Wind Left
17 Door Left
18 Wind Left
19 Wind Left
20 Wind Back
21 Wind Back
(NW)
4.0
0.360
0.300
315
90
(NW)
30.0
0.360.0.300
315
90
(NW)
80.0
0.360
0.300
315
90
(NW)
20.0
0.360-0.300
315
90
(NW)
80.0
0.360
0.300
315
90
(NW)
20.0
0.360
0.300
315
90
(NW)
64.0
0.360
0.300
315
90
(NW)
25.0
0.360
0.300
315
90
(NW)
6.8
0.360
0.300
315
90
(NW)
30.0
0.360
0.300
315
90
(NW)
9.8
0.360
0.300
315
90
(NW)
4.0
0.360
0.300
315
90
(NE)
80.0
0.360
0.300
45
90
(NE)
20.0
0.360
0.300
45
90
(NE)
18.0
0.360
0.300
45
90
(NE)
18.0
0.360
0.300
45
90
(NE)
24.0
0.360
0.300
45
90
(NE)
6.8
0.360
0.300
45
90
(NE)
12.0
0.360
0.300
45
90
(SE)
64.0
0.360
0.300
135
90'
(SE)
6.8
0.360
0.300
135
90,E
aq� �•yt• 3
Cti '%8en s
Standard FGLASSI/Clad/Openable
Standard FGLASS2/Clad/Openable
Standard FGLASS3/Clad/Door
Standard FGLASS4/Clad/Fixed
Standard FGLASS5/Clad/Door
Standard FGLASS6/Clad/Fixed
Standard FGLASS7/Clad/Door
Standard FGLASS8/Clad/Fixed
Standard FGLASS9/Clad/Fixed
Standard FGLASSIO/Clad/Openable
Standard FGLASSII/Clad/Fixed
Standard FGLASSI2/Clad/Openable
Standard LGLASSI/Clad/Door
Standard LGLASS2/Clad/Fixed
Standard LGLASS3/Clad/Openable
Standard LGLASS4/Clad/Openable
Standard LGLASS5/Clad/Door
Standard LGLASS6/Clad/Fixed
Standar-d_LGLAS_S_7_/Clad/ Fixed
S Fndard)BGLASSI-/Clad/.Fix
Stand"ard BGLA&S(S2-AC-ladVFYxA
BUILDING & SAFETY DEPT,
APPROVED
FOR CONSTRUCTION
DATE SY
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS
, Inc
i ' 1
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4
Project Title.. ....... McCreary Residence Date..01/06/14 13:11:41
MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R
User#-MP1751 User -Aero Energy Run -McCreary Residence I
-------------------------------------------------------------------------------
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
22 Door Back (SE) 300.0 0.450 0.300 135 90 Standard BGLASS3/Clad/Door/Sl
23 Door Back (SE) 48.0 0.360 0.300 135 90 Standard BGLASS4/Clad/Door
24 Door Back (SE) 48.0 0.360 0.300 135 90 Standard BGLASS5/Clad/Door
25 Wind Back (SE) 24.0 0.360 0.300 135 90 Standard BGLASS6/Clad/Fixed
26 Wind Back (SE) 6.8 0.360 0.300 135 90 Standard BGLASS7/Clad/Fixed
27 Door Back (SE) 48.0 0.360 0.300 135 90 Standard BGLASS8/Clad/Door
28 Wind Back (SE) 14.1 0.360 0.300 135 90 Standard BGLASS9/Clad/Fixed
29 Wind Back (SE) 4.0 0.360 0.300 135 90 Standard BGLASS10/Clad/Openable
30 Wind Back (SE) 4.0 0.360 0.300 135 90 Standard BGLASSII/Clad/Openable
31 Wind Back (SE) 6.8 0.360 0.300 135 90 Standard BGLASSI2/Clad/Openable
32 Door Right (SW) 100.0 0.450 0.300 225 90 Standard RGLASSI/Clad/Door./Bi
33 Wind Right (SW) 25.0 0.360 0.300 225 90 Standard RGLASS2/Clad/Fixed
34 Wind Right (SW) 4.0 0.360 0.300 225 90 Standard RGLASS3/Clad/Openable
35 Wind Right (SW) 4.0 0.360 0.300 225 90 Standard RGLASS4/Clad/Openable
36 Wind Right (SW) 6.8 0.360'0.300 225 90 Standard RGLASSS/Clad/Fixed
37 Win,B,Eght (SW) a22.5�s0360 Q�OQ2�5 Q� Stad RG�LAS$6 Clad/Fixed
38 Wil Rigt (SW) �1D. ���.36'0.�00 225 �0: �t a da RGLA�SS7Clad/Openable
39 Gr�nei
Right (S ) 5 ,0.36b Ok300 225 n ;. -andg & RGLA7 S8/Clad/Openable
L
ED
a
'gtypg. OVE
,,._., ' s -e ¢� s= '.-` fie' -handW
g ` ,�. 1_ A �.
__ _
Area Left Right
Surface (sf) Width Height Depth Height Extension Extension
----------- ----- ----- ------ ----- ------ --------- ---------
HOUSE
1 Window 4.0 n/a 2.0 2.0 1.0 n/a n/a
2 Window 30.0 n/a 6.0 2.0 1.0 n/a n/a
3 Door 80.0 n/a 8.0 2.0 1.5 n/a n/a
4 Window 20.0 n/a 2.5 2.0 0.5 n/a n/a
5 Door 80.0 n/a 8.0 2.0 1.5 n/a n/a
6 Window 20.0 n/a 2.5 2.0 0.5 n/a n/a
7 Door 64.0 n/a 8.0 2.0 1.5 n/a n/a
8 Window 25.0 n/a 4.0 2.0 2.0 n/a n/a
9 Window 6.8 n/a 1.5 1.5 1.0 n/a n/a
10 Window 30.0 n/a 6.0 2.0 6.0 n/a n/a
11 Window 9.8 n/a 2.5 2.0. 3.0 n/a n/a
12 Window 4.0 n/a 2.0 1.5 3.5 n/a n/a
13 Door 80.0 n/a 8.0 2.0 1.5 n/a n/a
14 Window 20.0 n/a 2.5 2.0 0.5' n/a n/a
15 Window 18.0 n/a 4.5 1.5 3..5n/a n/a
16 Window 18.0 n/a 4.5 1.5 7r 0___� n/ar ten,/a
17 Door 24.0 n/a 8.0 1.5 8.0����n. a LA Cna a��TA
18 Window 6.8 n/a 1.5 1.5 2.03UILDIfe'uag� SAFETY
TY DE
LDATE
NSTRUCTION
_ 8Y
•
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: CRICERTS, Inc
, it .
•
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5
Project Title .......... _ McCrearyResidenceDate..01/06/14 13:,11:41
-
MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R
User#-MP1751 User -Aero Energy Run -McCreary Residence
-------------------------------------------------------------------------------
Surface
19 Window
20 Window
21 Window
22 Door
23 Door
24 Door
25 Window
26 Window
27 Door -
28 Window
29 Window
30 Window
31 Window
32 Door
33 Window
34 dow
Wir-ow
6 Window
a= 7 Windo'.
X38 in w r
9mclp�d '- s
.F �r, s
Area
(sf)
12.0
64.0
6.8
300.0
48.0
48.0
24.0
6.8
48.0
14.1
4.0
4.0
6.8
100.0
25.0
4.0
OVERHANGS
---Window--- ---------- Overhan
Width
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a-
Left Right
Height Depth Height Extension Extension
2.0 1.5 1.0 n/a n/a
8.0 2.0 1.0 n/a n/a
1.5 1.5 2.0 n/a n/a
10.0 21.0 1.5 n/a n/a
8.0 10.0 1.5 n/a n/a
8.0 10.0 3.0 n/a n/a
2.0 10.0 0.0 n/a n/a
1.5 1.5 1.5 n/a n/a
8.0 1.5 4.0 n/a n/a
1.5 1.5 2.0 n/a n/a
2.0 1.5 1.0 n/a n/a
2.0 1.5 1.0 n/a n/a
1.5 1.5 1.0 n/a n/a
10.0 1.5 1.0 n/a n/a
5.0 1.5 6.0 n/a n/a
2.0..... 1-5._ __2_.5 _n/a _-.n/a
F
Area
Slab Type (sf)
---------------- ------
HOUSE
Standard Slab 4571
STUDIO
Standard Slab 260
HVAC SYSTEMS
------------
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/0
, Inc
Verified
Verified
Verified Verified Verified Maximum
System
Minimum
Refrig Charge Adequate Fan Watt Cooling
Type
----------------
Efficiency
-----------
EER
or CID Airflow Draw Capacity
HOUSE
-----
------------- -------- -------- --------
Gas
0.800 AFUE
n/a
n/a n/a n/a n/a
ACSplit
14.00 SEER
12.0
Yes Yes Yes No
STUDIO
HeatPump
'7.70 HSPF
n/a
CI a
n/a r�,/'a- LA Qrnb#NT
An
BUILDiIVG $ SAFETy DEPT.
APPROVE®
FOR CONSTRUCTION
DATE
---•__ 8y_
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/0
, Inc
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF71R Page 6
-----------=-------------------------------------------------------------------
-------------------------------------------------------------------------------
•
Project -Tit le .......... -McCreary -Residence
--------------Date__01/06/14-13:11_41
MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R
User#-MP1751 User -Aero Energy Run -McCreary Residence I
-------------------------------------------------------------------------------
:7
HVAC SYSTEMS
------------
HVAC SIZING
Verified
Verified
Sensible
Verified Verified
Verified
Verified
Maximum
System
Minimum Refrig Charge
Adequate
Fan Watt
Cooling
Type
Efficiency EER or CID
Airflow
Draw
Capacity
----------------
HPSplit
----------- ------------------
13.00 SEER No No
--------
No
--------
No
--------
No
HVAC SIZING
------------- ---------- ---------- ---------- ----------
HOUSE
Gas 111822 n/a n/a n/a
ACSplit n/a' 88345 109636 n/a
STUDIO
, EieatPump7 / D.
!?,Split n 9. n/ 3
Tot r 119507 f > 336: 115 x' E a }
. �. .
g n LOC
VAN s QU
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range ............... 34 F.
DUCT SYSTEMS
Verified
Total
Sensible
Design
Maximum
Heating
Cooling
Cooling
Cooling
System Load
Load
Capacity
Capacity
Type (Btu/hr)
(Btu/hr)
(Btu/hr)
(Btu/hr)
------------- ---------- ---------- ---------- ----------
HOUSE
Gas 111822 n/a n/a n/a
ACSplit n/a' 88345 109636 n/a
STUDIO
, EieatPump7 / D.
!?,Split n 9. n/ 3
Tot r 119507 f > 336: 115 x' E a }
. �. .
g n LOC
VAN s QU
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range ............... 34 F.
DUCT SYSTEMS
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE By
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc
Verified
Verified
Verified
System
Duct
Duct
Duct
Surface
Buried
Type
-------------
Location
-----------
R -value
-------
Leakage
Area
Ducts
HOUSE
-----------
--------
---------
Gas
Attic
R-6
Yes
No
No
ACSplit
Attic
R-6
Yes
No
No
STUDIO
HeatPump
Attic
R-4.2
No
No
No
HPSplit
Attic
R-4.2
No
No
No
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE By
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc
is
n
U
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 7
Project -Title ........... _McCreary _Residence
--------------Date__01/06/14-13_11_41
MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R I
User#-MP1751 User -Aero Energy Run -McCreary Residence I
-------------------------------------------------------------------------------
FAN SYSTEMS
Flow Power
System Type (cfm) (W/cfm)
--------------------------------
HOUSE
Standard 93.09 .25
STUDIO
Standard 4.1 .25
SPECIA F,EATUE AN,D Ng&HLING SSUMPTIONS
PF V
*** Items intff �- section��o ld b do entont r_,plans, ***
in}l %d �nanufac and �1 %eci $ tions nd
rie d ung Plan hie a d ina'cti n.
AIXOr
This -.i� d>ng:; inct5 mr , o Ir�ia a .K7 Are r e� °
This building incorporates a Radiant Barrier.
This building incorporates a non-standard Water Heating System.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF -4R installation certificate. ***
This building incorporates a HERS verified Improved Refrigerant Charge test
or the installation of a HERS verified Charge Indicator Display (CID). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified High Energy Efficiency Ratio (EER).
This building incorporates HERS verified Air Handler Ean-Watt r-aw. If a
cooling system is not installed, then HERS veri,ficat�iont-is�nnot- ne�cess�ary.
BUILDING & SAFE -TY DEPT.
AP P F'%0"V'
FOR CONSTRUCTION
DATE BY
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc
WATER HEATING
SYSTEMS
---------------------
Number
Tank
External
Heater
in
Energy
Size
Insulation
Tank Type
----------------
Type
--------
Distribution Type
-------------------
System
------
Factor
--------
(gal)
------
R -value
----------
WH1
1 SmallStorage
Gas
StandardNoInsul
1
.62
50
R-n/a
WH2
2 SmallStorage
Gas
Recirc/TimeTemp
1
.62
50
R-n/a
SPECIA F,EATUE AN,D Ng&HLING SSUMPTIONS
PF V
*** Items intff �- section��o ld b do entont r_,plans, ***
in}l %d �nanufac and �1 %eci $ tions nd
rie d ung Plan hie a d ina'cti n.
AIXOr
This -.i� d>ng:; inct5 mr , o Ir�ia a .K7 Are r e� °
This building incorporates a Radiant Barrier.
This building incorporates a non-standard Water Heating System.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF -4R installation certificate. ***
This building incorporates a HERS verified Improved Refrigerant Charge test
or the installation of a HERS verified Charge Indicator Display (CID). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified High Energy Efficiency Ratio (EER).
This building incorporates HERS verified Air Handler Ean-Watt r-aw. If a
cooling system is not installed, then HERS veri,ficat�iont-is�nnot- ne�cess�ary.
BUILDING & SAFE -TY DEPT.
AP P F'%0"V'
FOR CONSTRUCTION
DATE BY
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc
•
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 8
Project -Title .......... -McCreary -Residence - Date..01/06/14 13:11:41
MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R
User#-MP1751 User -Aero Energy Run -McCreary Residence
--------------------------- ---------------------------------------------------
HERS REQUIRED VERIFICATION
--------------------------
This building incorporates HERS verified Cooling Coil Airflow. If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF -4R. If the measured CFM is above the
target, then corrective action must be taken to reduce the duct leakage and
then must be retested. Alternatively, the compliance calculations could be
redone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
REMARKS
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
A�,n0���
FOR CONSTRUCTION
• DATE —_ _ 8Y
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: CaICERTS, Inc
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 9
•
Project -Title .......... -McCreary -Residence
--------------Date__01/06/14-13_11_41
I MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R
User#-MP1751 User -Aero Energy Run -McCreary Residence
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESI ER or OWNER,, DOCUMENTATION AUTHOR
�cQ�
Name....Name.... Terry Statum
Company. 'Suzcfki s ns Company. Aero Energy
Address. 4931 Hemlock Address. 15434 Shelton Drive
Irvine, Ca. 92612 Lake Mathews, CA 92570
Phone... 949-307-4216 Phone... 951-776-4140
License.
6A
Signed.. ( �fSigned.. p(p J+
(date) dae)
ENFORCEMENT AGENCY 9j�(
TA 1C ... 2: ..
F. s,
y .t
Pile . r- hJ �t `iti 61
. a u n -
q' 11 , N
�.:,. •- ri y
s
Signed..
(date)
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.,
APPROVE®
FOR CONSTRUCTION
Electronically Signed at Ca10ERTS.com by Russell Flynn (Suzuki Designs) 1/6/2014
i DATE --- BY
Electronically Filed by Terry Statum and Authenticated at CalCERTSI.com - 1/6/20T4
Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/O1/06_�14c5r4a57�1{ERS-prcvkderr—Ca1CBRTS, Inc
� � T
•
•
STATE OF CALIFORNIA
MANDATORY MEASURES SUMMARY: RESIDENTIAL
CEG MF -1R Revised 08109 CALIFORNIA ENERGY COMMISSION "
Mandatory Measures Summa MF -1R
Residential (Page 1 of 3
Site Address: Enforcement Agency: 77Date:
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed,
regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -IR,
CF -IR -ADD, or CF -IR -ALT Form) shall supersede the items marked with an asterisk(*) below. This Mandatory Measures
Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum
component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all
applicable sections o the MF -IR Form with plans.
DESCRIPTION
Building Envelope Measures:
§ 116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient
SHGC , and infiltration that meets the requirements of 10-11l(a).
§117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and scaled.
§118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§ 1 I8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of § i 18(i) when the installation of
a Cool Roof is specified on the CF -1R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
§ 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150(c): Minimum R-13 insulation in wood -frame wall or equivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor.
§150(0: Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -IR Form.
§ 150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§1500): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no
eater than 2.0perm/inch and shall be protected from phnical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150(e)IB: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped
with a with a readily accessible, operable, and fight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the
building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve,
backflow prevention, pumpisolation valve and recirculation loop connection requirements of § 113(c)5.
§ 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an
electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters.
§ 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§ 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§ 1 506) l A: Storage gas water heaters rated with an Energy Factor no grater than the federal minimal standard are externally wrapped with
insulation having an installed thermal resistance ofR-12 or greater. I_
§ 1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar wateicheagngr"system�,_rotheiriridiiec�iothvater f� have R-12
external insulation or R-16 internal insulation where the inlemal insulation-R-value•is;indicated o ttbe6exle ' r .f-tbq.tank.
§ 1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-iecirctilaling sy'sfems, and en'tirel'ehg if Ve6irdula ' ig sections
of hot water pipes are insulated per Standards Table 150-B. f 14 P P P (_)\ ,/
§ 1500)2: Cooling system piping (suction, chilled water, or brine lines),and pipingiinsulated-betweeti.heitiri_g•source fidimct hot w ter tank
shall be insulated to Table I50 -B and Equation 150-A. .1 rUr l VUN.� I I-SUiai 1 1VIV
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems4>15 psi, meets the requirements of Standards Table 23-A.
2008 Residential Compliance Forms
I DATE BY (August 2009
It A. .
0
•
•
STATE OF CALIFORNIA
MANDATORY MEASURES SUMMARY: RESIDENTIAL
:EC-MF-iR (Revised 08109) CALIFORNIA ENERGY COMMISSION
Mandatory Measures Summary MF -1R
Residential (Page 2 of 3
Site Address: Enforcement Agency: Date:
§ I506)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space.
§1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
Ducts and Fans Measures:
§150(m)l: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602,
603, 604, 605 and Standard 6-5; supply -air and return-airducts and plenums are insulated to a minimum installed level of R-4.2 or
enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable
requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to
seal openings ater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§ 150(m)l : Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal,
duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts.
Ducts installed in cavities and support platforms shall not be cbmpressed to cause reductions in the cross-sectional area of the ducts.
§ 150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape
is used in combination with mastic and draw bands.
§ l 50(m)7: Exhaust fans stems have back draft or automatic dampers.
§ I50(m)8: Gravity ventilating systems serving oonditioned space have either automatic or readily accessible, manually operated dampers.
§ 150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that
can cause degradation of the rraterial.
§ 150(m)10: Flexible ducts cannot have porous inner cores.
§ 150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in
Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating S stems and Equipment Measures:
§ l 14(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations;
an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use
electric resistance heating ora pilot light.
§ 114(b)l : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return
lines, or built-up connections for future solar heating
§ 114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
§ I50(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of § 150(p).
Residential Lighting Measures:
§ 150(k)l : High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in
Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined as specified by § 130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
§ 150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high
efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -voltage
lamp holder; OR shall be rated b consume no more than five watts of power as determined by §I30(d), and shall not contain a medium
screw -base socket.
--------
§150(k)6: Li hting integral to exhaust fans, in -rooms other than kitchens, shall meet the a licable� uiiemerits of 1.50 =
§150(k)7: All switchingdevices and controls shall meet the requirements of §150(k)7,',. B U I l n i 1\ (n^_ V
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kittcch� shill be'high" effidac}c: H F.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f or 100 watts for dwelling, units -larger th�W2 00�fh may be xempt
from the 50°/a high efficacy requirement when: all low efficacy luminaires in ttie,�ki iche��re clo trolled b Tmanu al on occ pant
sensor, dimmer, energymanagement stem EMCS , or a multi -scene programmable control s',&gkand al( eManentl stalled
2008 Residential Compliance Forms
DATE SYugust 2009
•
•
STATE OF CALIFORNIA
MANDATORY MEASURES SUMMARY: RESIDENTIAL
CEC- MF -1R Revised 08109 CALIFORNIA ENERGY COMMISSION
Mandatory Measures Summa MF -1R
Residential(Page 3 of 3
Site Address: Enforcement Agency: Date:
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§ 150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high
efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of § 119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occv ant sensor.
§ 150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility
rooms shall be high efficacy lummnaires.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch
that complies with the applicable requirements of § 119, or by a manual -on occupant sensor that complies with the
applicable requirements of § 119.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply
with § I50 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or
other nationally recognized testingtrating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then
2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing
and ceiling.
§ l 50(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling
units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot
shall be high efficacy.
EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual
on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the
following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an
energy management control system (FMCS) not having an override or bypass switch that allows the luminaire to be
always on
EXCEPTION 2: Outdoor luminaires used to comply with Exception 1 to § 150(k)13 may be controlled by a temporary override switch
which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six
hours.
EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of
the California Electric Code need not be high efficacy luminaires.
§ 150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five
watts of power as determined according to § 130(d).
§ 150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in
Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of
Sections 130, 131, 134, and 146
§ I50(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units
shall be high efficacy luminaires.
EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s)
certified to com2ly with the applicable requirements of § 119.
2008 Residential Compliance Forms
CITY OF LA BUILDING & SAFETY DET.
PT
APPROVED
FOR CONSTRUCTinm
DATE 8Y