Loading...
14-0069 (SFD)P.O. BOX 1504 78-495 CALL•E TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 14'-000:0-0-0.69 _ Owner: Property Address: 8'03°0:5 VIA CAPRI MCCREARY RESIDENCE APN: 772-440-052- - - 40101 MONTEREY AVE. #B1\214 Application description: DWELLING - SINGLE FAMILY DETACHED RANCHO MIRAGE, CA 92270 Property Zoning: LOW DENSITY RESIDENTIAL (760) 773-6633 Application valuation: 495305 Applicant: - Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 533670 Date':Co_ n�� tra or. OWNER -BUILDER DECLARATION I hereby affirm under penalty of erjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the.structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, -and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 lam exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/29/14 Contractor: SUNROSE CORPORATION 40101 MONTEREY AVE STE RANCHO MIRAGE, CA 92270 _ B1-2 �� _ d# (760)773-6633 Lic. No.. 533670 +( I CIV, OF 6.A ri UINTA ----------------------------'-_-_--,;wr.Itp , ----- WORKER'S COMPENSATION DE 'CXWnO I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1948056-2014 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should became subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (5100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to center upon the above-mentioned property for inspection purposes. Date: F; Signature (Applicant or Agent): _ Application Number . . . . . 14-00000069 ------ Structure Information NEW SFD ----- Other struct info . . . . . CODE EDITION 2013 # BEDROOMS 5.00 FIRE SPRINKLERS 13-D 6340 GARAGE SQ FTG 1046.00 V PATIO SQ FTG 2727.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 4831.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 463.00 Permit . . . BUILDING 2013 Additional desc . . Permit Fee . . . . 739.19 Plan Check Fee 00 Issue Date . . . . Valuation . . . . 495305 Expiration Date 10/26/14 Qty Unit Charge Per Extension BASE FEE 573.43 296.00 ---------------------------------------------------------------------------- .5600 THOU BLDG $200,001-$1M 165.76 Permit . . . ELECTRICAL 2013 Additional desc . . Permit Fee . . . . 263.62 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/26/14 Qty Unit Charge Per Extension .00 23.8300 LS ELEC FIXTURES, FIRST 20 .00 1.00 23.8300 EA ELEC SERVICES 23.83 1.00 23.8300 EA ELEC TEMP POWER POLES 23.83 1.00 143.0000 LS ELEC NEW RES, FIRST 1 KSF 143.00 6.00 ---------------------------------------------------------------------------- 12.1600 EA ELEC NEW RES, ADD'L 1 KSF 72.96 Permit . . . MECHANICAL 2013 Additional desc . . Permit Fee 583.96 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date . . 10/26/14 Qty Unit Charge Per Extension 6.00 35.7500 EA MECH FURNACE 214.50 1.00 11.9200 EA MECH APPL REP/ALT 11.92 6.00 35.7500 EA MECH CONDENSER/COMP 214.50 10.00 11.9200 EA MECH VENT FAN 119:20 LQPERMIT Application Number . . . . . 14-00000069 Permit . . . MECHANICAL 2013' Qty Unit Charge Per Extension 2.00 ------------------------------------ 11.9200 EA MECH EXHAUST HOOD --------------------------=------------- 23.84 Permit . . . PLUMBING 2013 Additional desc . Permit Fee . . . . 429.11 Plan Check Fee .00 Issue Date . . . . Valuation . . . . •0 Expiration.Date 10/26/14 Qty Unit Charge Per Extension 29.00 11.9200 EA PLBG FIXTURE/TRAP 345.68 1.00 11.9200 EA PLBG BUILDING SEWER 11.92 2.00 11.9200 EA PLBG WATER HEATER/VENT 23.84 1.00 11.9200 EA PLBG WATER INST/ALT/REP ,11.92 1.00 35.7500 LS PLBG GAS SYS, 5+ OUTLETS 35.75 ---------------------------------------------------------------------------- Special Notes and Comments NWE SFD 5294 SQ. WITH 2727 SQ. FT. PATIO DECK AND 1046 SQ.FT.GARAGE.HOME IS FIRE SPRINKLED PER 2013 CRC CODES. THIS PERMIT DOES NOT INCLUDE POOL SPA, BLOCK WALLS OR DRIVEWAY APPROACH, BBQ, OR FIRE -PIT February 13, 2014 1:49:40 PM jjohnson. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 738.26 BLDG STDS ADMIN (SB1473) 20.•00 DIF COMMUNITY CENTERS -RES 129.00 DIF CIVIC CENTER - RES 942.00 DIF FIRE PROTECTION -RES 433.00 DIF LIBRARIES - RES 344.00 PLAN CHECK, ELECTRICAL 105.85 DIF PARK MAINT FAC - RES 40.00 PLAN CHECK, MECHANICAL 347.97 PLAN CHECK, SFD GRADING 143.00 PLAN CHECK, PLUMBING 407.65 DIF PARKS/REC - RES 2048.00 BLDG PC 200K -1M 1590.54 .STRONG MOTION (SMI) - RES 49.53 TUMF: RESIDENTIAL 1837.44 DIF STREET MAINT FAC -RES 116.00 DIF TRANSPORTATION - RES 2842.00 Fee summary ----------------- Charged Paid Credited ---------------------------------------- Due LQPERMIT Application Number . . . . . 14-00000069 Permit Fee Total 2015.88 .00 Plan Check Total .00 .00 Other Fee Total' 12134.24 1250.00 Grand Total 14150.12 1250.00 LQPERMIT 00 2015.88 00 1.00 00 10884.24 00 12900.12 Buildin( Addres Owner, eh; p Mailing Addres o - 30s - V Ire Ti4 4 4 a" P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 1� c6c_ zqG ceea r s yo -10 ►o-�yd3t -2 /1/ Zip Tel. P�Id Ci 2- 760 -773 ;tor l.Nif�ie �r�d%2r�Da1 Zip Tel. oA -c e �76e)-723-663' & Classif. 33 (, D Lic. # Arch., Engr., Designer Address Tel. City r Zip State lV'l//n G! Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not appy to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. It, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not appy to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. OCC. GRP. A.P. Number -777-- 160 06_3 Legal Description tot t `t —1,5- Project 5Project Description eot,7 ?)4'1k.--74- t4• 51--d Sq. Ft. ��� �� No. No. Dw. Size i Stories 2-- Units New k Add ❑ Alter ❑ Repair ❑ . Demolition ❑ IEstimated Valuation /. r PERMIT AMOUNT Plan Chk. Dep. , Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure 67 TOTAL Q CONTACT INFORMATION NAME: PHONE: ZONE: BY: Minimum Setback Distances: Front Setback Side Side FINAL DATE Issued by: Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Coachella Vill`ey Unified School District This Box For District Use only 83-7.33 Avenue 55, Thermal; CA 92274 DEVELOPER FEES PAID (760) 398-5909 — Fax (760) 398-1224 AREA: .. AMOUNT .. .. LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMWIND. AMOUNT: DATE: RECEIPT: CHECK- #: - INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: McCreary Residence @ The Hideaway Date: Apri125, 2014 . Owner's Name: Phone No. 7607773-6633 Project Address: 80-305 Via Capri, La Quinta, CA 92253 ' Project Description: Single Family Dwelling Unit APN: 777-100-053 Tract #: Lot #'s: Type of Development: Residential . XX Commercial Industrial Total Square Feet of Building Area: 5,294 SQ FT Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of.perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.. Dated: Signature:..i�—x SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH'ONE OF THE FOLLOWING: (CIRCLE ONE) . Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 5,294 Amount per Sq.Ft. $3.20 Amount Collected. $16,940.80 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst Signa / re: NOTICE OF 90 DAY PERIOD FOR PROTEST OF AND�_ATEMT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires t t th' istrict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest periodin, regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020'of the Government code. Additionally, the amount ofthe fees imposed is as herein set forth, whether payable at this time or in whole or in part. prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted.' MV:c/mydocs/devfees/certificate of compliance form updated 3-2007 11/2010 Documents pmlded by Data7ree LLC On ft's proprietary Imaging and deDdery system. Copyright 2003. All rights reserved. RECPRDING REQUESTED BY: LAWYERS -1 V LE Lawyers Title WHEN RECORDED MAIL DOCUMENT AND TAX STATEMENT TO: Charles J. McCreary, Trustee 2480 St. Laurent Place Frisco, TX 75034 APN: 777-100-053-4 TITLE ORDER NO.: 613690616 DOC # 2013-0099681 02/28/2013 08:00 AM Fees: $21.00 Page 1 of 3 Doc T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk & Recorder "This document was electronically submitted to the County of Riverside for recording— Receipted by: CTOLOSSA U ( 34 wl 0L* I to THIS SPACE FOR RECORDER'S USE ONLY --tf?,(a 0 ZA - ( to0 GRANT DEED The undersigned Grantor(s) declare that the DOCUMENTARY TRANSFER TAX IS: $ 473.00 County XX computed on the full value of the interest of property conveyed, or —computed on the full value less the value of liens or encumbrances remaining thereon at the time of sale. OR transfer is EXEMPT from tax for the following reason FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Daniel J. Freimuth and Colleen M. Freimuth, Co -Trustees of The Freimuth Family Trust Dated June 21, 1999 HEREBY GRANT(S) to Charles J. McCreary, as Trustee of The Charles J. McCreary Management Trust UTD December 18, 2012 All that real property situated in the City of La Quinta, County of Riverside, State of California, described as; Lots 14 & 15 of Amended Tract 29894-2, more completely described per Exhibit "A" attached hereto and made a part hereof. Commonly Known As_80305-Via Capri,_La.Quinta, CA_92253 Dated: February 5, 2013 STATE OF CALIFORNIA } COUNTY OF C9Yta!:w 1 On __ Z\ -t \ �O t3 , before me, "A- L Aqy"'f , a Notary Public personally appeared fVaj4ct -X •=Neirtw�4L� Ar CQ\tetK AA- 4=✓ a %VMv ACA, who proved to me on the basis of satisfactory evidence to be the personto whose namepj is/41'0 subscribed to the within instrument and acknowledged to me that he/shel By executed the same in his/hedj�t+ authorized capacity(VO, and that by his/heqgtQPsignaturete on the instrument the persori5� or the entity upon behalf of which the person4s),acted, executed the instrument. Cv� I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature ka Mail tax statements to Return address as shown above The Friemuth Family Trust June 21, 1999 M.LOCEY Commieslon / 1864451 a Notary Public - California = Z Orange County M Comm. E ices Oct 7, 2013 (SEAL) 0 Documents provided by DataTree LLC vla trs proprietary Imaging antl delNery system. Copyright 2003, All rights reserved. DOC #2013-0099681 Page 2 of 3 02/28/2013 08:00 AM GOVERNMENT CODE 27361.7 I CERTIFY UNDER PENALTY OF PERJURY THAT THE NOTARY SEAL ON THE DOCUMENT TO WHICH THIS STATEMENT IS ATTACHED READS AS FOLLOWS: NAME OF NOTARY: M. Lacey COMMISSION NO: 1864451 PLACE OF EXECUTION: Orange DATE COMMISSION EXPIRES: 10-7-13 MANUFACTURE /V R NO: NNA 1 SIGNATURE: DATE: Z _a l? -/3 uuunnenu p—meo oy uam i ree Lu: via its proprietary Imaging and deWery system. Copyright 4003, All rights reserved. DOC #2013-0099681 Page 3 of 3 02/28/2013 08:00 AM EXHIBIT "Art THE LAND REFERRED TO HEREIN IS SITUATED IN THE COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS: PARCEL 1: LOTS 14 AND 15 OF AMENDED TRACT NO. 29894-2, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 327, PAGES 56 THROUGH 88, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY AND SHOWN ON GRANT DEED RECORDED APRIL 1, 2003 AS INSTRUMENT NO. 2003-260913 OF OFFICIAL RECORDS, GRANT DEED REFLECTS PARCEL MERGER NO. 2003-401, AS APPROVED BY THE CITY OF LA QUINTA. EXCEPTING THEREFROM INTEREST IN ALL WATER, MINERALS, OIL, GAS, PETROLEUM, OTHER HYDROCARBON SUBSTANCES AND ALL GEOTHERMAL ENERGY SOURCES IN OR UNDER SAID LAND OR WHICH MAY BE PRODUCED FROM SAID LAND. PARCEL 2: NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION RECORDED ON DECEMBER 13, 2002, AS INSTRUMENT NO. 2002-745939, OF OFFICIAL RECORDS. ASSESSOR'S PARCEL NUMBER: 777-100-053-4 April 7, 2014 Mr. Charles McCreary 2480 St. Laurant Place Frisco, TX 75034 Re: Lot 14-15 at 80305 Via Capri Final Working Drawings #2 Dear Mr. McCreary, The Hideaway Design Review Committee (DRC) reviewed the revised final working drawings at their April 1, 2014 meeting. The project was approved to start construction; however, the following comments must be addressed prior to the request for setback observation at the lot. 1. Some of the required architectural detailing was still missing from the plan submittal (ex. wrought iron rails, stucco recesses, etc.): In addition, some of the details were not keyed in as required. Please provide all appropriate detailing and proper call -outs. 2. The chimney cap detail appears small for the architectural design presented and may not work properly with the tile roofing proposed. Please review this detail and modify as necessary. 3. A smooth transition is required with the landscape at the adjacent lot (southwest side). 4.' Bougainvillea "Torch Glow" cannot be maintained in an aesthetically pleasing way at a maximum height of three feet. The committee recommends the use of a plant that can be maintained appropriately at 3' as required in the rear yard view corridors. 5. Sheet L-5 shows an entry wall and pot elevations but no construction details were provided. Please contact Brook Marshall at 760-219-8057 or, by email at DRCFacilitator@gmail.com with any questions regarding this review or to schedule your Pre -Construction Meeting once a Building Permit has been obtained. Sincerely, The Hideaway Design Review Committee cc: Andy Suzuki GM Future Designs Mike Tuvell DRC File AERO ENERGY TITLE 24 CALCULATIONS 15434 SHELTON DRIVE LAKE MATHEWS,.CA., 92570 951-776-4140 Date: 14-14 OWNER: MCCREARY RESIDENCE VIA A LA QUINTA, CA 92253 LRECEIVED A PROJECT; CUSTOM RESIDENCE JAN 2 3` 2014 80305 VIA CAPRI THE HIDEAWAY — LOTS 14/15 CITY OF LA QUINTA LA QUINTA, CA. ^', COMMUNITY DEVELOPMENT ** 2008 ENERGY STANDARDS ** STATEMENT OF COMPLIANCE. The energy conservation standards for new residential buildings as set forth in Title24, Part 2, Chapter 2-53; and Title 20,, Chapter 2, Subchapter 4, article 1, of the California Administrative Code, have been Reviewed. This design conforms to all requirements as they apply in Climate Zone 15 using Micropas 8, Version 8.11, a California Energy Commission approved computer performance program for the 2008 Energy Standards. PREPARED BY: :�t0(14- TERRY M. STATUM C.E.A. #RO8-07-269 C,E.P.E. #R08-99-1651, 'L �F� oI s Q Vjj1nIT FOR P AFE�, DEP r A. UCT/0N mos _aYi i SA- 0 n �J ** SUMMARY SHEET ** Proiect: McCreary Residence — 80305 Via Capri, La Quinta, Ca. Zone: 15 Custom Residence Wall Insulation: R-19 in 2x6 Exterior Walls and interior of double walls Ceiling Insulation: R-30 Radiant Foil Barrier: IS Required Raised Floor Insulation: R-19 over Garage Slab Edge Insulation: None Glazing Type: All glass is DUAL PANE with Low -E Glass. (See Notes) Minimum Furnace AFUE: 80% AFUE for Main House 7.7 HSPF for Studio Minimum Heating Capacity: Main House = 111,822 Btu/Hr Studio = 7,685 Btu/Hr Minimum A/C SEER: Main House = 14.0 SEER / 12.0 EER Studio = 13.0 SEER A/C Tonnage: Main House = Min.Sens.= 88,345 Btu/Hr (A/C Size By Mech. Contractor) Studio = Min.Sens. = 5,019 Btu/Hr (A/C Size by Mech. Contractor) Duct Insulation: R-6.0 For Ducts & Plenums in Unconditioned Spaces (Main House Duct Leakage Test IS Required, Not Studio) Note(s): 1) See CF -1 R for Main House required HERS Measures. 2) All windows and glass doors (except Weiland) can have clad frames with a weighted average NFRC U -factor of .36 or less and a weighted average NFRC SHGC of .30 or less with Low -E glass. 3) Weiland Doors weighted average NFRC U -Factor of .45 and a weighted average NFRC SHGC of .30. 4) Water Heaters Minimum Energy Factor Temp. control (on one unit only). CWY Recirc. Pump & Time BU p N F LA C�UINT G & SAFETY DEPT. FpR ��®VSD ONSTRUCT/ON DATE - By Continuous Ventilation Calculation CFA =100 + 7.5 (# of Bedrooms +1) = Ventilation Rate (Min. CFM @ .25" W.C.) McCreary Residence, 80305 Via Capri, La Quinta, Ca. Main House 5,034 + 100 + 7.5 (4 + 1) = 50.34 + 37.5 = 87.84 Min. CFM Studio 260 =100 + 7.5 (1+1) = 2.6 + 15.0 =17.6 Min. CFM Studio Fan Selection: Broan #SSQTXE080 (or Equal) (One Required) 55 CFM @.25" W.C. .3 Sones Ventilation Exhaust Duct Size: 6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual) No Limit on Duct Length • Main House Fan Selection: Broan #SSQTXE110 (or Equal) (One Required) 90 CFM @.25" W.C. .7 Sones • Ventilation Exhaust Duct Size: 6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual) 125' Max. Length Less 15' for each elbow CITY OF BUILDING & LA QUI NTA S,gPETpEPT. APPRo��® FOR CONS jRUCi7pN rqr�-� ay CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 1 ------- ------------------------------------------------------- • Project Title . McCreary Residence Date01/06/1413_11_41 Project Address........ 80305 Via Capri ******--------------------- -- - La Quinta, Ca. 92253 *v8.l* Documentation Author... Terry Statum ****** I Building Permit # I Aero Energy I I 15434 Shelton Drive I Plan Check Date I Lake Mathews, CA 92570 I I 951-776-4140 I Field Check Date I Climate Zone..... ..... 15 --------------------- Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r01) ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R User#-MP1751 User -Aero Energy Run -McCreary Residence I ------------------------------------------------------------------------------- • • ---------------------------- ---------------------------- MICROPAS8 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance Percent = (kTDV/sf-yr) Design Design Margin Improvement = - ----------------------- ---------- ---------- ___w -------- ----------- _ = Space Heating.......... 6.48 8.18 -1.70 -26.2% - = Space Cooling.......... 89.71 83.21 6.50 7.2% _ Ventilation Fans....... 0.56 0.56 0.00. 0.0% _ = Water Heating.......... 6.49 8.15 -1.66 -25.6% _ Rro, Totals 103.24 103 2�.4c.fva i 5,• t e.1r4 a vy;.. 3.0% 0 10 V Y,R[ B 1 g colfiplj ith �cmp�r P MEL '* ylerifica `ol4Req}or G lean __J------==.�_____� ----------- -- -= -- -- ------ HERS Verification.......... Conditioned Floor Area..... Building Type .............. Construction Type .......... Natural Gas at Site ....... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Required 5294 sf Single Family Detached New Yes Front Facing 315 deg (NW) 1 2 FullYear Slab On Grade 2 67983 cf 4831 sf 25 % of floor area 0.39 Btu/hr-sf-F 0.3 12.8 ft Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014 CITY OF �q ���P�BLILDING & D A ORD ROVE® FOR CONSTRUCTION DATE gY , Inc CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 • Project -Title .......... McCreary -Residence --------------Date,_O1/06/14-13_11_41 MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R User#-MP1751 User -Aero Energy Run -McCreary Residence ------------------------------------------------------------------------------- BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- HOUSE Residence 5034 65291 0.95 5.7 Yes Setback 2.0 Standard No STUDIO Residence 260 2692 0.05 0.2 Yes Setback 2.0 Standard No ATTIC AND ROOF DETAILS ---------------------- Frame R- R - Roof Roof Re- Emiss- Frame Spac- Value Value Vent Mass Rise flect- ivity Depth ing Above Below Area Vent Roof Type (lb/sqft) ance (in.) (in.) Deck Deck Ratio High ----------- --------- ---- ------ ------ ----- ----- ------ ------ ------ ---- HOUSE Tile Heavy 3:12 0.10 0.85 3.5 24 oc 0.00 0.00 1/300 0.00 STUDIO Tile Heavy 3:12-10-10„ 0 8�_ 24,.oc 0,..Q0 .0..00 1/300 0.00 J ,..,' .`? � m"-:, � rw ' _A4_',Pk_ :.� • y F0�AQUE SUC cs ��` sr`' 0. U_eat F' r dear Anpe fac;` it n�iis`JA4 y o t��iaijn/ "c'r R�# ?�it�`bx� yam` • Y eri Sur fa":.ems Typ..bn4r�6m HOUSE 1 Wall Wood 230 0.071 19 0 315 90 Yes 4.3.1 A23 Front 2x6 Wall 2 Wall Wood 1230 0.071 19 0 315 90 Yes 4..3.1 A23 Front Dbl.Wall 4 Wall Wood 326 0.071 19 0 315 90 No 4.3.1 A23 Gar. 2x6 Wall 5 Wall Wood 688 0.071 19 0 45 90 Yes 4.3.1 A23 Left 2x6 Wall 6 Wall Wood 1135 0.071 19 0 45 90 Yes 4.3.1 A23 Left Dbl.Wall 8 Wall Wood 590 0.071 19 0 135 90 Yes 4.3.1 A23 Back 2x6 Wall 9 Wall Wood 1244 0.071 19 0 135 90 Yes 4.3.1 A23 Back Dbl.Wall 11 Wall Wood 938 0.071 19 0 225 90 Yes 4.3.1 A23 Right 2x6 Wall 12 Wall Wood 867 0.071 19 0 225 90 Yes 4.3.1 A23 Right Dbl.Wall 14 Wall Wood 110 0.071 19 0 225 90 No 4.3.1 A23 Gar. 2x6 Wall 15 AtticRad Wood 4208 0.031 30 0 n/a 0 Yes 4.2.1 A20 Vented Attic 17 Roof Rad Wood 365 0.032 30 0 45 27 Yes 4.2.1 A8 Vaulted Roof 18 RoofRad• Wood 365 0.032 '30 0 225 27 Yes 4.2.1 A8 Vaulted Roof 19 F1oorExt Wood 357 0.048 19 0 n/a 0 No 4.4.2 A4 Over Garage 20 Door Wood 24 0.500 0 0 315 90 Yes 4.5.1 A4 Bed.3 Door 21 Door Wood 48 0.500 0 0 315 90 Yes 4.5.1 A4 Bed.4 Door 22 Door Wood 24 0.500 0 0 31.5 90 No '4.5.1 A4 Garage Door STUDIO 3 Wall Wood 156 0.071 19 0 315-0�T90 Yes 4'..3�; 1, �A20IN ro t 2x6 Wall 7 Wall Wood 108 0.071 19 0 4f5,UIL90,1pFo 4; 3.1__A 3 G r •x6 Wall •� 'Datr-t I Y2 DEPT. ,ROVE® FOR CONSTRUCTION •DATE Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc ," .. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-iR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- • Project -Title .......... -McCreary -Residence --------------Date__O1/06/14-13_11_41 ------------- MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15SO8 Program -FORM CF -1R User#-MP1751 User -Aero Energy Run -McCreary Residence ------------------------------------------------------------------------------- • 0 OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing .Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ ----- ---- ----- ----- ----- --- ---- --- --------- -------------- 10 Wall Wood 152 0.071 19 0 135 90 Yes 4.3.1 A23 Back 2x6 Wall 13 Wall Wood 154 0.071 19 0 225 90 Yes 4.3.1 A23 Right 2x6 Wall 16 AtticRad Wood 260 0.031 30 0 n/a 0 Yes 4.2.1 A20 Vented Attic PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar JA4 Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ -------------------------- -------------- --------------------- HOUSE 23 S1abEdge 87 0.730 R-0/Oin No 4.4.7 Al Exposed edge 24 SlabEdge 15 0.730 R-0/Oin No 4.4.7 Al Exposed edge 25 S1abEdge 349 0.730 R-0/Oin No 4.4.7 Al Covered edge 26 S1abEdge 58 0.730 R-0/Oin No 4.4.7 Al Covered edge Or HO'u�r, 1 Wind Front 2 Wind Front 3 Door Front 4 Wind Front 5 Door Front 6 Wind Front 7 Door Front 8 Wind Front 9 Wind Front 10 Wind Front 11 Wind Front 12 Wind Front 13 Door Left 14 Wind Left 15 Wind Left 16 Wind Left 17 Door Left 18 Wind Left 19 Wind Left 20 Wind Back 21 Wind Back (NW) 4.0 0.360 0.300 315 90 (NW) 30.0 0.360.0.300 315 90 (NW) 80.0 0.360 0.300 315 90 (NW) 20.0 0.360-0.300 315 90 (NW) 80.0 0.360 0.300 315 90 (NW) 20.0 0.360 0.300 315 90 (NW) 64.0 0.360 0.300 315 90 (NW) 25.0 0.360 0.300 315 90 (NW) 6.8 0.360 0.300 315 90 (NW) 30.0 0.360 0.300 315 90 (NW) 9.8 0.360 0.300 315 90 (NW) 4.0 0.360 0.300 315 90 (NE) 80.0 0.360 0.300 45 90 (NE) 20.0 0.360 0.300 45 90 (NE) 18.0 0.360 0.300 45 90 (NE) 18.0 0.360 0.300 45 90 (NE) 24.0 0.360 0.300 45 90 (NE) 6.8 0.360 0.300 45 90 (NE) 12.0 0.360 0.300 45 90 (SE) 64.0 0.360 0.300 135 90' (SE) 6.8 0.360 0.300 135 90,E aq� �•yt• 3 Cti '%8en s Standard FGLASSI/Clad/Openable Standard FGLASS2/Clad/Openable Standard FGLASS3/Clad/Door Standard FGLASS4/Clad/Fixed Standard FGLASS5/Clad/Door Standard FGLASS6/Clad/Fixed Standard FGLASS7/Clad/Door Standard FGLASS8/Clad/Fixed Standard FGLASS9/Clad/Fixed Standard FGLASSIO/Clad/Openable Standard FGLASSII/Clad/Fixed Standard FGLASSI2/Clad/Openable Standard LGLASSI/Clad/Door Standard LGLASS2/Clad/Fixed Standard LGLASS3/Clad/Openable Standard LGLASS4/Clad/Openable Standard LGLASS5/Clad/Door Standard LGLASS6/Clad/Fixed Standar-d_LGLAS_S_7_/Clad/ Fixed S Fndard)BGLASSI-/Clad/.Fix Stand"ard BGLA&S(S2-AC-ladVFYxA BUILDING & SAFETY DEPT, APPROVED FOR CONSTRUCTION DATE SY Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS , Inc i ' 1 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4 Project Title.. ....... McCreary Residence Date..01/06/14 13:11:41 MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R User#-MP1751 User -Aero Energy Run -McCreary Residence I ------------------------------------------------------------------------------- FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 22 Door Back (SE) 300.0 0.450 0.300 135 90 Standard BGLASS3/Clad/Door/Sl 23 Door Back (SE) 48.0 0.360 0.300 135 90 Standard BGLASS4/Clad/Door 24 Door Back (SE) 48.0 0.360 0.300 135 90 Standard BGLASS5/Clad/Door 25 Wind Back (SE) 24.0 0.360 0.300 135 90 Standard BGLASS6/Clad/Fixed 26 Wind Back (SE) 6.8 0.360 0.300 135 90 Standard BGLASS7/Clad/Fixed 27 Door Back (SE) 48.0 0.360 0.300 135 90 Standard BGLASS8/Clad/Door 28 Wind Back (SE) 14.1 0.360 0.300 135 90 Standard BGLASS9/Clad/Fixed 29 Wind Back (SE) 4.0 0.360 0.300 135 90 Standard BGLASS10/Clad/Openable 30 Wind Back (SE) 4.0 0.360 0.300 135 90 Standard BGLASSII/Clad/Openable 31 Wind Back (SE) 6.8 0.360 0.300 135 90 Standard BGLASSI2/Clad/Openable 32 Door Right (SW) 100.0 0.450 0.300 225 90 Standard RGLASSI/Clad/Door./Bi 33 Wind Right (SW) 25.0 0.360 0.300 225 90 Standard RGLASS2/Clad/Fixed 34 Wind Right (SW) 4.0 0.360 0.300 225 90 Standard RGLASS3/Clad/Openable 35 Wind Right (SW) 4.0 0.360 0.300 225 90 Standard RGLASS4/Clad/Openable 36 Wind Right (SW) 6.8 0.360'0.300 225 90 Standard RGLASSS/Clad/Fixed 37 Win,B,Eght (SW) a22.5�s0360 Q�OQ2�5 Q� Stad RG�LAS$6 Clad/Fixed 38 Wil Rigt (SW) �1D. ���.36'0.�00 225 �0: �t a da RGLA�SS7Clad/Openable 39 Gr�nei Right (S ) 5 ,0.36b Ok300 225 n ;. -andg & RGLA7 S8/Clad/Openable L ED a 'gtypg. OVE ,,._., ' s -e ¢� s= '.-` fie' -handW g ` ,�. 1_ A �. __ _ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------ --------- --------- HOUSE 1 Window 4.0 n/a 2.0 2.0 1.0 n/a n/a 2 Window 30.0 n/a 6.0 2.0 1.0 n/a n/a 3 Door 80.0 n/a 8.0 2.0 1.5 n/a n/a 4 Window 20.0 n/a 2.5 2.0 0.5 n/a n/a 5 Door 80.0 n/a 8.0 2.0 1.5 n/a n/a 6 Window 20.0 n/a 2.5 2.0 0.5 n/a n/a 7 Door 64.0 n/a 8.0 2.0 1.5 n/a n/a 8 Window 25.0 n/a 4.0 2.0 2.0 n/a n/a 9 Window 6.8 n/a 1.5 1.5 1.0 n/a n/a 10 Window 30.0 n/a 6.0 2.0 6.0 n/a n/a 11 Window 9.8 n/a 2.5 2.0. 3.0 n/a n/a 12 Window 4.0 n/a 2.0 1.5 3.5 n/a n/a 13 Door 80.0 n/a 8.0 2.0 1.5 n/a n/a 14 Window 20.0 n/a 2.5 2.0 0.5' n/a n/a 15 Window 18.0 n/a 4.5 1.5 3..5n/a n/a 16 Window 18.0 n/a 4.5 1.5 7r 0___� n/ar ten,/a 17 Door 24.0 n/a 8.0 1.5 8.0����n. a LA Cna a��TA 18 Window 6.8 n/a 1.5 1.5 2.03UILDIfe'uag� SAFETY TY DE LDATE NSTRUCTION _ 8Y • Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: CRICERTS, Inc , it . • CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 Project Title .......... _ McCrearyResidenceDate..01/06/14 13:,11:41 - MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R User#-MP1751 User -Aero Energy Run -McCreary Residence ------------------------------------------------------------------------------- Surface 19 Window 20 Window 21 Window 22 Door 23 Door 24 Door 25 Window 26 Window 27 Door - 28 Window 29 Window 30 Window 31 Window 32 Door 33 Window 34 dow Wir-ow 6 Window a= 7 Windo'. X38 in w r 9mclp�d '- s .F �r, s Area (sf) 12.0 64.0 6.8 300.0 48.0 48.0 24.0 6.8 48.0 14.1 4.0 4.0 6.8 100.0 25.0 4.0 OVERHANGS ---Window--- ---------- Overhan Width n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a- Left Right Height Depth Height Extension Extension 2.0 1.5 1.0 n/a n/a 8.0 2.0 1.0 n/a n/a 1.5 1.5 2.0 n/a n/a 10.0 21.0 1.5 n/a n/a 8.0 10.0 1.5 n/a n/a 8.0 10.0 3.0 n/a n/a 2.0 10.0 0.0 n/a n/a 1.5 1.5 1.5 n/a n/a 8.0 1.5 4.0 n/a n/a 1.5 1.5 2.0 n/a n/a 2.0 1.5 1.0 n/a n/a 2.0 1.5 1.0 n/a n/a 1.5 1.5 1.0 n/a n/a 10.0 1.5 1.0 n/a n/a 5.0 1.5 6.0 n/a n/a 2.0..... 1-5._ __2_.5 _n/a _-.n/a F Area Slab Type (sf) ---------------- ------ HOUSE Standard Slab 4571 STUDIO Standard Slab 260 HVAC SYSTEMS ------------ Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/0 , Inc Verified Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type ---------------- Efficiency ----------- EER or CID Airflow Draw Capacity HOUSE ----- ------------- -------- -------- -------- Gas 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 14.00 SEER 12.0 Yes Yes Yes No STUDIO HeatPump '7.70 HSPF n/a CI a n/a r�,/'a- LA Qrnb#NT An BUILDiIVG $ SAFETy DEPT. APPROVE® FOR CONSTRUCTION DATE ---•__ 8y_ Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/0 , Inc CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF71R Page 6 -----------=------------------------------------------------------------------- ------------------------------------------------------------------------------- • Project -Tit le .......... -McCreary -Residence --------------Date__01/06/14-13:11_41 MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R User#-MP1751 User -Aero Energy Run -McCreary Residence I ------------------------------------------------------------------------------- :7 HVAC SYSTEMS ------------ HVAC SIZING Verified Verified Sensible Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type Efficiency EER or CID Airflow Draw Capacity ---------------- HPSplit ----------- ------------------ 13.00 SEER No No -------- No -------- No -------- No HVAC SIZING ------------- ---------- ---------- ---------- ---------- HOUSE Gas 111822 n/a n/a n/a ACSplit n/a' 88345 109636 n/a STUDIO , EieatPump7 / D. !?,Split n 9. n/ 3 Tot r 119507 f > 336: 115 x' E a } . �. . g n LOC VAN s QU Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F. DUCT SYSTEMS Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) ------------- ---------- ---------- ---------- ---------- HOUSE Gas 111822 n/a n/a n/a ACSplit n/a' 88345 109636 n/a STUDIO , EieatPump7 / D. !?,Split n 9. n/ 3 Tot r 119507 f > 336: 115 x' E a } . �. . g n LOC VAN s QU Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F. DUCT SYSTEMS CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE By Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R -value ------- Leakage Area Ducts HOUSE ----------- -------- --------- Gas Attic R-6 Yes No No ACSplit Attic R-6 Yes No No STUDIO HeatPump Attic R-4.2 No No No HPSplit Attic R-4.2 No No No CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE By Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc is n U CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 7 Project -Title ........... _McCreary _Residence --------------Date__01/06/14-13_11_41 MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R I User#-MP1751 User -Aero Energy Run -McCreary Residence I ------------------------------------------------------------------------------- FAN SYSTEMS Flow Power System Type (cfm) (W/cfm) -------------------------------- HOUSE Standard 93.09 .25 STUDIO Standard 4.1 .25 SPECIA F,EATUE AN,D Ng&HLING SSUMPTIONS PF V *** Items intff �- section��o ld b do entont r_,plans, *** in}l %d �nanufac and �1 %eci $ tions nd rie d ung Plan hie a d ina'cti n. AIXOr This -.i� d>ng:; inct5 mr , o Ir�ia a .K7 Are r e� ° This building incorporates a Radiant Barrier. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -4R installation certificate. *** This building incorporates a HERS verified Improved Refrigerant Charge test or the installation of a HERS verified Charge Indicator Display (CID). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified High Energy Efficiency Ratio (EER). This building incorporates HERS verified Air Handler Ean-Watt r-aw. If a cooling system is not installed, then HERS veri,ficat�iont-is�nnot- ne�cess�ary. BUILDING & SAFE -TY DEPT. AP P F'%0"V' FOR CONSTRUCTION DATE BY Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type ---------------- Type -------- Distribution Type ------------------- System ------ Factor -------- (gal) ------ R -value ---------- WH1 1 SmallStorage Gas StandardNoInsul 1 .62 50 R-n/a WH2 2 SmallStorage Gas Recirc/TimeTemp 1 .62 50 R-n/a SPECIA F,EATUE AN,D Ng&HLING SSUMPTIONS PF V *** Items intff �- section��o ld b do entont r_,plans, *** in}l %d �nanufac and �1 %eci $ tions nd rie d ung Plan hie a d ina'cti n. AIXOr This -.i� d>ng:; inct5 mr , o Ir�ia a .K7 Are r e� ° This building incorporates a Radiant Barrier. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -4R installation certificate. *** This building incorporates a HERS verified Improved Refrigerant Charge test or the installation of a HERS verified Charge Indicator Display (CID). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified High Energy Efficiency Ratio (EER). This building incorporates HERS verified Air Handler Ean-Watt r-aw. If a cooling system is not installed, then HERS veri,ficat�iont-is�nnot- ne�cess�ary. BUILDING & SAFE -TY DEPT. AP P F'%0"V' FOR CONSTRUCTION DATE BY Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: Ca10ERTS, Inc • CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 8 Project -Title .......... -McCreary -Residence - Date..01/06/14 13:11:41 MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R User#-MP1751 User -Aero Energy Run -McCreary Residence --------------------------- --------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- This building incorporates HERS verified Cooling Coil Airflow. If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CITY OF LA QUINTA BUILDING & SAFETY DEPT. A�,n0��� FOR CONSTRUCTION • DATE —_ _ 8Y Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/01/06 14:54:57 HERS Provider: CaICERTS, Inc CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 9 • Project -Title .......... -McCreary -Residence --------------Date__01/06/14-13_11_41 I MICROPAS8 v8.1 File-MCCREARY Wth-CTZ15S08 Program -FORM CF -1R User#-MP1751 User -Aero Energy Run -McCreary Residence ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESI ER or OWNER,, DOCUMENTATION AUTHOR �cQ� Name....Name.... Terry Statum Company. 'Suzcfki s ns Company. Aero Energy Address. 4931 Hemlock Address. 15434 Shelton Drive Irvine, Ca. 92612 Lake Mathews, CA 92570 Phone... 949-307-4216 Phone... 951-776-4140 License. 6A Signed.. ( �fSigned.. p(p J+ (date) dae) ENFORCEMENT AGENCY 9j�( TA 1C ... 2: .. F. s, y .t Pile . r- hJ �t `iti 61 . a u n - q' 11 , N �.:,. •- ri y s Signed.. (date) CITY OF LA QUINTA BUILDING & SAFETY DEPT., APPROVE® FOR CONSTRUCTION Electronically Signed at Ca10ERTS.com by Russell Flynn (Suzuki Designs) 1/6/2014 i DATE --- BY Electronically Filed by Terry Statum and Authenticated at CalCERTSI.com - 1/6/20T4 Reg: 214-N0000883C-000000000-0000 Registration Date/Time: 2014/O1/06_�14c5r4a57�1{ERS-prcvkderr—Ca1CBRTS, Inc � � T • • STATE OF CALIFORNIA MANDATORY MEASURES SUMMARY: RESIDENTIAL CEG MF -1R Revised 08109 CALIFORNIA ENERGY COMMISSION " Mandatory Measures Summa MF -1R Residential (Page 1 of 3 Site Address: Enforcement Agency: 77Date: NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -IR, CF -IR -ADD, or CF -IR -ALT Form) shall supersede the items marked with an asterisk(*) below. This Mandatory Measures Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections o the MF -IR Form with plans. DESCRIPTION Building Envelope Measures: § 116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-11l(a). §117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and scaled. §118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. § 1 I8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of § i 18(i) when the installation of a Cool Roof is specified on the CF -1R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. § 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall or equivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. §150(0: Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -IR Form. § 150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §1500): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no eater than 2.0perm/inch and shall be protected from phnical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § 150(e)IB: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and fight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pumpisolation valve and recirculation loop connection requirements of § 113(c)5. § 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. § 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). § 1 506) l A: Storage gas water heaters rated with an Energy Factor no grater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance ofR-12 or greater. I_ § 1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar wateicheagngr"system�,_rotheiriridiiec�iothvater f� have R-12 external insulation or R-16 internal insulation where the inlemal insulation-R-value•is;indicated o ttbe6exle ' r .f-tbq.tank. § 1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-iecirctilaling sy'sfems, and en'tirel'ehg if Ve6irdula ' ig sections of hot water pipes are insulated per Standards Table 150-B. f 14 P P P (_)\ ,/ § 1500)2: Cooling system piping (suction, chilled water, or brine lines),and pipingiinsulated-betweeti.heitiri_g•source fidimct hot w ter tank shall be insulated to Table I50 -B and Equation 150-A. .1 rUr l VUN.� I I-SUiai 1 1VIV §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems4>15 psi, meets the requirements of Standards Table 23-A. 2008 Residential Compliance Forms I DATE BY (August 2009 It A. . 0 • • STATE OF CALIFORNIA MANDATORY MEASURES SUMMARY: RESIDENTIAL :EC-MF-iR (Revised 08109) CALIFORNIA ENERGY COMMISSION Mandatory Measures Summary MF -1R Residential (Page 2 of 3 Site Address: Enforcement Agency: Date: § I506)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. Ducts and Fans Measures: §150(m)l: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return-airducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings ater than 1/4 inch the combination of mastic and either mesh or tape shall be used § 150(m)l : Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be cbmpressed to cause reductions in the cross-sectional area of the ducts. § 150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § l 50(m)7: Exhaust fans stems have back draft or automatic dampers. § I50(m)8: Gravity ventilating systems serving oonditioned space have either automatic or readily accessible, manually operated dampers. § 150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the rraterial. § 150(m)10: Flexible ducts cannot have porous inner cores. § 150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating S stems and Equipment Measures: § l 14(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. § 114(b)l : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating § 114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § I50(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of § 150(p). Residential Lighting Measures: § 150(k)l : High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined as specified by § 130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. § 150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -voltage lamp holder; OR shall be rated b consume no more than five watts of power as determined by §I30(d), and shall not contain a medium screw -base socket. -------- §150(k)6: Li hting integral to exhaust fans, in -rooms other than kitchens, shall meet the a licable� uiiemerits of 1.50 = §150(k)7: All switchingdevices and controls shall meet the requirements of §150(k)7,',. B U I l n i 1\ (n^_ V §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kittcch� shill be'high" effidac}c: H F. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f or 100 watts for dwelling, units -larger th�W2 00�fh may be xempt from the 50°/a high efficacy requirement when: all low efficacy luminaires in ttie,�ki iche��re clo trolled b Tmanu al on occ pant sensor, dimmer, energymanagement stem EMCS , or a multi -scene programmable control s',&gkand al( eManentl stalled 2008 Residential Compliance Forms DATE SYugust 2009 • • STATE OF CALIFORNIA MANDATORY MEASURES SUMMARY: RESIDENTIAL CEC- MF -1R Revised 08109 CALIFORNIA ENERGY COMMISSION Mandatory Measures Summa MF -1R Residential(Page 3 of 3 Site Address: Enforcement Agency: Date: luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. § 150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of § 119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occv ant sensor. § 150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy lummnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of § 119, or by a manual -on occupant sensor that complies with the applicable requirements of § 119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with § I50 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testingtrating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. § l 50(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (FMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception 1 to § 150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. § 150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to § 130(d). § 150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146 § I50(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to com2ly with the applicable requirements of § 119. 2008 Residential Compliance Forms CITY OF LA BUILDING & SAFETY DET. PT APPROVED FOR CONSTRUCTinm DATE 8Y August 2009