Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-0146 (SFD)
P.O. BOX 1504 4 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT. ,• Application Number: 12-0000- 034:166_,,,,,,,_� Owner: Property Address: 803-50 `VIA CAPR'I DORWARD, DAVID & JANICE APN: 772-440-076- - - 80350 VIA CAPRI Application description: DWELLING -.SINGLE FAMILY DETACHED LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 426799 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/.17/12 Contractor: Applicant: Architect or Engineer: CCAD CONSTRUCTION INC 78060 CALLE ESTADO STE 12 I VA- 1 3 LA .QUINTA, CA 92253 (760) 285-8712 LAgiVINSA Jf .� r l Lic. No.:. 962962 �+�� p�CIDS5 ----------------------------------------•---- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License N 962962 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ate: ntractor: I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier GRANITE STATE Policy Number 065255344 . following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person_in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by 3700 of the Labor Code, y shall "forthwith comply with those provisions. �� 11 / any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: • ate: -ZA licant: ( 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself Through his or her own employees, provided that the- DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044,. Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). . ( 1 I am exempt under Sec. , B.&P.C. for this 'reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: 4 Lender's Address: A APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives - off t/hi's co my to enter upon the above -mentioned property for ion.purposes a1, te:i �'1 S' ature (Applicant or Agent): LQPERMIT Application Number . . . . . 12-00000146 Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . DWELLG/LODGING/CONG <=10 Other struct info CODE EDITION 2010 # BEDROOMS 4.00 FIRE SPRINKLERS YES. GARAGE SQ FTG 1177.00 PATIO SQ FTG 1020.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 3874.00 ----------------------------------------------------------------------- .2ND FLOOR SQUARE FOOTAGE 831.00 Permit . . . BUILDING PERMIT .Additional desc . Permit Fee 1784.00 Plan Check Fee 1159.60 Issue Date . . . . Valuation . . . . 426799 Expiration Date'. 1/13/13 Qty Unit Charge Per Extension BASE FEE 639.50 327.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 1144.50 Permit . . . MECHANICAL Additional desc . Permit Fee 122.00 Plan Check Fee 3.0.50 Issue Date . . . . Valuation 0 Expiration Date 1/13/13 Qty Unit Charge Per Extension BASE FEE T5._00 4.00 9.0000 EA MECH FURNACE <=100K 36.00' 1.00 11.0000 EA MECH FURNACE >100K 11.00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 2.00 16.5000 --"-------------------------------------------------------------------------- EA MECH B/C >3-15HP/>100K-500KBTU 33.00 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 238.62 Plan Check Fee 3741.99 Issue Date . . . . Valuation . . . . 0 Expiration.Date 1/13/13 Qty Unit Charge Per Extension BASE FEE 15.00 4705.00 .0350 ELEC NEW RES - 1 OR-2 FAMILY 164.68 LQPERMIT Application Number . . . . 12-00000146 Permit . . . . . . ELEC-NEW RESIDENTIAL Qty Unit Charge Per Extension 2197.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 43.94 1.00 15.0000 EA ELEC TEMPORARY POWER.POLE ---------7----------------------------------------------------------- 15.00 ------- Permit . . ._ PLUMBING Additional desc . Permit Fee . . 234.00 Plan Check Fee 58.5.0 Issue Date . . . Valuation . . . 0 Expiration Date 1/13/13 Qty Unit Charge Per Extension BASE FEE 15.00 25.00 6.0000 EA PLB FIXTURE 150.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.6000 EA PLB LAWN SPRINKLER SYSTEM 9.00 16.00 .7500• EA PLB GAS PIPE >=5 12.00 1.00 15.0000 EA PLB GAS METER ---------------------------------------------------------------------------- 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 1/13/13 Qty Unit Charge Per Extension -BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 4705 SF 2 STORY SFD. TYPE V-B CONSTRUCTION W/ FIRE SPRINKLERS,.. R-3 OCCUPANCY. 2010 CODES. 2008 DIF. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, BBQ'S and DRIVEWAY APPROACH** ARCHITECT: ROBERT J PESTER C22046 -------------------------------------- ------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES-RES 567.00 BLDG STDS ADMIN (SB1473) 18.00 DIF COMMUNITY CENTERS-RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 115.96 DIF FIRE PROTECTION-RES 140.00 LQPERMIT Application Number 12-00000146 Other Fees . . . . . . . DIF LIBRARIES - RES 355.00 MULTI -SPECIES (MSHCP) FEE 1254.00 DIF PARK MAINT.FAC.- RES 22.00. DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 42.68 DIF STREET MAINT FAC-RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due Permit Fee Total 2393.62 .00 .00 2393.62 Plan Check Total 4990.59 1000.00 .00 3990.59 Other Fee Total 6472.64 00 .00 6472.64 Grand Total 13856.85 1000.00 .00 12856.85 LQPERMIT Tit, ap 4 4 " P.O. BOX 1504 Building �n 78-495 CALLE TAMPICO Address �a `� J'� VIA UPA-k LA QUINTA, CALIFORNIA 92253 Owner tpc Address X>- d , '?�ox 54&61 City & Classif. I Lic. # Arcn., tngr., Designer Tel. City I up I state Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to Me a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that 1 have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above -mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT APPLICATION ONLY BUILDING: TYPE CONST. OCC. GRP. A.P. Number T 1' - Z Legal Description V Project Description NEw SLI�✓�LC i"I'a M C I m i Sq. Ft. �y t ` P No. No. Dw. Size 11 S �I Z Stories Units New 9 Add ❑ Alter ❑ Repair ❑ Demolition ❑ Corr T,AGT: rIFM O -,10a r>�hjl`4 Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing it: S.M.I. Grading LIPA,QU1Pf Driveway Enc. - Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE_ Issued by: Validated by: — Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE ' CoAdhella Valley Unified School District -83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FFFS PAID, AREA: AMOUNT LEVEL ONE AMOUNT: - LEVEL IVO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: - RECEIPT: CHECK #: - INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 1.7620) Project Name: Hidea—� Date: July 11, 2012 Owner's Name: David.& Janice Dorward Phone No. 801-592-2529 Project Address: 80-Via Capri, LaQuinta, CA 92253. Project Description: Single Family Dwelling APN: 777-100-077 Tract #: Lot #'s: Type of Development: Residential !XX Commercial Industrial Total Square Feet of Building Area: 4,705 Certification of Applicant/Owners: The person signing certifies that the aboveinformation is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on .6hall,of-the- i r/developer. Dated: July 11, 2012 Signature: ****************************************,'****************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN.OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code _ Project 65995 Approval 4705 $3.20 $15056.00 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Secretary Signature:Aa�� �wwt U� NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/ntydocs/devfees/certificate of compliance form updated 3-2007 : 11/2010 41. RECC)RdING REQUESTED BY Lawyers Title - IE WHEN RECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: David Dorward 1032-8— 8t A%&^L4r. sDMow-cO•o, At9>69-T'A , QAt4 aoA,7- to C 1 x Z APN: 777-100-077-6 Escrow -No: PDL10647-LT139-CM DOC # 2011-0033989 01/21/2011 01:44P Fee:18.00 Page 1 of 2 Doc T Tax Paid Recorded in•Official Records County of Riverside Larry N. hard Assessor, County Clerk d Recorder I 111111111111111111 IN 11111111111111111111111111111111 S R U PAGE SIZE DA MISC LONG RFD COPY A I L 465 1 42647CORIAOR SMF NCHG T: CTY I UNI GRANT DEED ' irU OZd • lc.00 THE .UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $247.50 ® City of La Quinta 034 FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged, National Bank of Arizona, a National Banking Association hereby GRANT(S) to David C. Dorward and Janice Dorward, husband and wife as joint tenants the hollowing described real property In the County of Riverside, State of CALIFORNIA: For legal description of the real property herein, see Exhibit A attached hereto and made a part hereof. Commonly known as: 80350 Via Capri Unit Lot 62 and 63, La Quinta, CA 92253 Dated: lanuary 14. 20i2 STATE OFcupa& ARtzv"A COUNTYOF MA-kir-OAA _ )SS: On J_A-vV,4Ay it 2ci , before me, 4 Ft�VMs a Notary Public, (here insert name anA title of the officer) personally a 9 peared 4 ui cl Z�ruA"f� �Q �r�s;fir who proved to me on the basis of satisfactory evidence to be the person(o whose named/are subscribed,to D ithin instruent and acknowledged t me that a/they executed the same in her/their rized capadty( cis), and that by her/their signature ) on the /insir'timent the pers ) or the entity u on behalf of which the perso acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature National Bank of Arizona, a National Banking Association David A. th, Vice President WID A. ZANATH, VICE PRESIDENT FOR NATIONAL BANK OF ARIZONA OFFICIAL SEAL THAD FLORES NOTARY PUBUC - State of Arizona MARICOPA COUNTY MY comm. Expires July 8.2012 (This area for notary stamp) MAIL TAX STATEMENTS AS DIRECTED ABOVE • File No: 6116901SO EXHIBIT "A" All that certain real property situated In the County of Riverside, State of California, described as follows: PARCEL NO. 1: LOTS 62 AND 63 OF AMENDED TRACT NO. 29894-2, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 327, PAGES 56 THROUGH 88, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY AS SHOWN ON GRANT DEED RECORDED APRIL 14, 2003 AS INSTRUMENT NO. 2003-261026 OF OFFICIAL RECORDS. SAID GRANT DEED REFLECTS PARCEL MERGER NO. 2003-425, AS APPROVED BY THE CITY OF LA QUINTA. EXCEPT THEREFROM THE OIL, GAS, MINERALS, AND OTHER HYDROCARBON SUBSTANCES LYING BELOW THE SURFACE OF SAID LAND, AS PROVIDED IN DEEDS OF RECORD. PARCEL NO. 2: NONEXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION RECORDED DECEMBER 13, 2002 AS INSTRUMENT NO. 2002-745930, OF OFFICIAL RECORDS. APN: 777-100-077-6 a CLTA Preliminary Report Form - Modified (11-17-06) Page 3 HIDEAWAY OWNERS ASSOCIATION May 15, 201.2, Mr. & .Mrs. David Dorward #300; IQ328-81. Avenue Edmonton, Alberta T6.E 1X2, Canada. RE: Dorward/Lot 62/63 at 80350 Via Capri .Final Design Review Dear Mr. & Mrs. Dorward: The Hideaway Design Review Committee (DRC) reviewed and approved. the Final Working Drawings subject to the following stipulations being addressed prior to the, request for Setback Observation at the lot: 1.. "There is a gate structure and walls that, are shown in the rear yard setback, off the Master Bedroom Terrace area. Typically this structure, and walls over 3 feet, would not be allowed; however; due,, to the location of'this lot (adjacent to Hideaway Club Drive) the 'committee would review a Variance ,request favorably. .However, the pillars that are over 6' and the .roof structure will not be allowed.. and wouldnot be reviewed .favorably if included with .your Variance Request. Please; submit at your eartlest convenience for review by the DRC and the Board of :Directors. 2. Please provide cut sheets and specifications for all exterior wall mounted sconces. Con.fo.rmance with hei.bh.t:restrictions, per the guidelines, should: be identified as well (ex. light source on side yard walls no higher than the property line wall). I The off -property planting mtistbe .reviewed by :Hort Tech (on. behalf of the Association).. Hort Tech may elect .to install the planting and irrigation on your behalf and. you would be responsible for 'reimbursement: ' Your General Contractor should discuss this directly with ii ort Tech. 4. Please specify, on the plant legend, what material, will be used .for ground cover. If decomposed, granite; please specify siie and color and submit a sample for approval. The cobble sample should;also be submitted for approval. 5. The grading plan shows the stone walls in the rear yard higher than 18" which is not allowed exceptwhereapproved by Variance: 6. There does not appear to be irrigation to the patio pots. Please provide irrigation. Please contact Brook Marshall at Brookrritlor by phone at (760) 219-8057 with any questions or to schedule your Pre Construction Meeting at the Jot prior to any work commencing and/or any signage or temporary construction ;facilities being brought on site. Your Building :Permit, isurance Requirements and' Construction :Deposit aredue at the time of. the Pre Construction Meeting. Sincerely, .Tire Hideaway Design Review Committee cc: Robert Pester; jp-aia:0cox.ne Gerry Tarsitanq wade.Howery, ifort'.rcch DRC file 80955 Avenue 52 La Quinta, CA 92253 P: 760 393-5210 R 760 398-.5788 CITY OF LA QUINTA"SUB-CONTRACTOR LIST JOB ADDRESS PERMIT NUMBER OWNER- ` -,ki D Lb(2LJA-94::' BUILDER 980�- This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous *place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must. be completed by applicant. "On File" is not an acceptable response. Trade Classification Contractor ::: ...::..:::.......:....:.. . ::.: , .;:..;>:;<.. ,:.::...>.: a ..........:. :::...:;:. StaLe..Contractor s. Licens . . :; :.: - Woikeis.Com ensat�o�;lrisu�ari `..:':.. '.`;:>,'-: ;< i::.:. City Busir;e s License :. Company Name Classification (e.g. A, B, C-8) License Number (xxxxxxl Exp. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date Ixx/xx/xx) License Number (xxxx) Exp, Date (xx/xx/xx) EARTHWORK (C712) .: CONCRETE (C-81 FRAMING '(C-5) STRUCT.. `STEEL- (G-51) MASONRY (C-291 �Q ( E. �j ��- �( 1 30 1 srfi�C c a�rtrio^ 1 TAI 2 1( Lg 2-" 7 3l PLUMBING (C-36) LATH; PLASTER (Ca35) DRYWALL (C-9) ...- ELECTRICAL. (C=10) :... RQOFING'(C'*39) 'SHEET. METAL (C=43) .:f''I_ FLOORING lC*:15); "; iZOPI`GL -i`� cj nsT { i ci 3o I ca,,, p� snsr a.. ' 3d ? 31 1r GLAZING (C-171. INSULATION:: (C72) SEWAGE DISP (C-41) PAINTING (C=33) CERAMIC TILE (C-54) CABINETS (C-6) AD / oZ rj ( 9 30 m�tM $ 2- FENCING (C713) LANDSCAPING (C=27.).':; POOL (C-53) PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org April 16, 2012 Dave Williams 81-595 Rancho Santana Dr. La Quinta, CA 92253 Re: Residential Fire Sprinkler Plan'Review 80-350 Via Capri La Quinta, CA 92253 F l- .OF LA QUINTA LDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT tZ BY �'•- .. The above referenced sprinkler plans have been reviewed and are acceptable by the. Riverside County Fire Department and are approved with the following conditions: 1) Approval of these plans does not include the piping of the underground system. 2) Permanently marked identification signs shall be attached to all control valves. 3) A sign shall be located adjacent to the alarm bell worded as follows: SPRINKLER FIRE ALARM - WHEN BELL RINGS CALL 911 4) A warning`sign, with minimum 1/4 inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system.for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to •the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: ` (a) Fire Riser Flush (b) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (c) Final inspection. ` The Fire Department job. card, approved plans and conditions`letter.must beat the job site or NO inspection will be performed. Applicant/installer shall be responsible to ' contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection dale.. ' All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863=8886. Applicant%installer, shall be responsible to contact the Fire Department to schedule inspection. r, Sincerely,. By Jason Stubble Fire- Safety Specialist CITY OFi0i A • BUILDING &T. ` ' APP FOR CO , DAT - f Prepared By: Dave Williams Dave Williams Plumbing and Electrical 81-595 Rancho Santana Dr. La Quinta, CA 92253 760-296 1397 • 4/2/2012 APR 05 2012 Fire Sprinkler. Hydraulics Calculation Program f Elite Software Development, Inc. lFIRE-: Eglirt Gutierrez Design Lot 62 and 63 Palm DesertCA 92211 '° {..a`. Page 2 General Project Data, Report General Data - - - - Project Title: Lot 62 and 63 Project File Name: ' -Lot 62 and 63..fiw Designed By: Dave Williams Date: 4/2/2012 Code Reference: NFPA 13D 'Approving Agency: Local Jurisdiction - Client Name: Robert John Pester, Architec , Phone: 805 689=3169 Address: 643 East MichelTorena Street City, State Zip Code: Santa Barbara, Ca 93103 Company Name: Dave Williams Plumbing and Representative: Dave William Jr. . Electrical Company Address: 81-595 Rancho Santana Dr. City And State: La Quinta, CA 92253 Phone: 760-2961397 C-16 Contractor ' Building Name: Lot 62 and 63 Building Owner: Contact at Building: - Phone at Building: Address Of Building: 80-530 Via Capri City, State Zip Code: La Quinta, CA 92253 �. At Hideaway Country Club Project Data Description Of Hazard: Ordinary 1 Sprinkler System Type: Wet Design Area Of Water Application: 196 ft2 Maximum Area Per Sprinkler: 256 ft2 Default Sprinkler K-Factor: 4.95 K Default Pipe Material: CPVC SDR 13.5 Inside Hose Stream Allowance: 0.00 gpm - Outside Hose Stream Allowance: 0.60, gpm In Rack Sprinkler Allowance: .14.00 gpm Sprinkler Specifications Make: Reliable -Model: Size: .5 .. Temperature Rating: 165 F Water Supply Test Data - Source Of Information: CVWD Test Hydrant ID: 80-350 Via,Capri Date Of Test: - Hydrant Elevation: 26 ft Static Pressure: 112.00 psi Test Flow Rate: 784.00 gpm Test Residual Pressure: 85.00 psi - Calculated System Flow Rate: 29.58 gpm Calculated Inflow Residual Pressure: 15.94 psi Available Residual Pressure At 111.94 psi System Flow. Calculation Project Data Calculation Mode: Demand _ HMD Minimum Residual Pressure: 9.00 psi' Minimum Desired Flow Density: 0.05 gpm/ft2 Maximum Water Velocity: 8.50 ft/s Maximum Frictional Loss / 100 feet:, 14.62. psi } Number Of Active Nodes: _ 10 Number Of Active Pipes: 9 Number. Of Inactive Pipes: 0 Number Of Active Sprinklers: - 2 - Number Of Inactive Sprinklers: 0 - C:\Users\Eglert\Documents\Elite Software\Fire 6 Projects\ d 63..fiw' Wednesday, April 04, 2012, 10:06 AM µ FIRE � Fire Sprinkler Hydraulics Calculation Program - t :' Elite Software Development; Inc. Eglert Gutierrez Design, L Lot 62 and 63 Palm Desert: CA 92211 ` - 1.ws. Page 3 Fiee Sprinkler Input Data Node Input Data + Area Group Sprinkler Pressure Node Elev (ft) Non -Sprinkler Node Node Description Branch Dia. KFactor (K). Estimate (psi) Branch Non- Flow (gpm) No. Branch Description (in) Branch Len. Branch Stnd -Stnd Fittings. . Branch Sprk (ft) • Fittings (ft) KFactor (K) 10 'Sprinkler A 4.90 9.00 10.00 0.00 . -- •' t 0.000 0.0 --- 0.0 0.00 20 No Discharge B� N/A 9:10 10.00 0.00 . -- 0.000 0.0 - -- 0.0 +' 0.00 - 30 Sprinkler A • 4.90 9.22 r 10.00 0.00 -- 0.000 0.0 --- 0.0. . 0.00 • 40 No Discharge B „ N/A 9.31 10.00 0.00 -- .: 0.000 . 0.0 --- 0.0 0.00- 50 No Discharge B N/A 10.48 10.00 0.00 ---- 0.000 '0.0 -- 0.0 0.00 60 No Discharge ' - B N/A 9.33 15.00 0.00 ' - 0.000 0.0 --- 0.0 0.00. - 70 No Discharge B N/A 10.32 , 15.00 0.00 . --- 0.000 0.0 % -- 0.0 0.00 80 No Discharge B N/A 13.76 . 10.00 -' 0.00 •0.00 - 0.000 0.0 -- r 0.0 90 No Discharge B N/A, 13.81 11.00 .0.00 -- 0.000 OA 0.0. 0.00 100 No Discharge B N/A 15.94 '11.0.0 • 0.00 --- 0.000 0.0 ---- - 0.0 0.00 .y C:\Users\Eglert\Documents\Elite Software\Fire 6 Projects \ d 63..fiw. Wednesday, April 04, 2012, 10:06 AM k ics FIRE =Fire kl Spriner HydraulCalculation Program . " , EliCSoftware Development, Inc. EglertCtierrez Desigm- ' s^ Lot 62 and 63 Palm Desert, CA' 92211 ` ` Page 4 Fire Sprinkler Input Data Pipe Input Data Beg. End. Nominal. Type Fitting Nominal Fitting .. Total CFactor Pipe Description Node - Node Diameter Group Data . Length Length Length (gpm/inch- (inch) , (feet) (feet) feet ( feet ) Psi) . 10 20 CPVC SDR 13.5 1:000 0 2.79 0.00 2.79 . 150 20 • 40 CPVC SDR 13.5 1.250 0 17.25 0.00 • 17.25 150 30 40 CPVC SDR 13.5 •1.000 0 2.37 ' 0.00 2.37 150 40 50 ' CPVC SDR 13.5 1.250 0 26.75 0.00 26.75 • 150 50 60 CPVC SDR 13.5 .1.250 0 23.50 0.00 23.50 150 '60 i 70 CPVC SDR 13.5 •1.250 0 22.62 0.00 22.62 150 •' 70 80 CPVC SDR 13.5. 1.250 0 29.33 •0.00 29.33 150 80 90 CPVC SDR 13.5 ' 1.250 0 10.92 .. 0.00 . 10.92 150 _ 90 100 CPVC SDR 13.5 1.250 0 49.00. 0.00 49.00 150 1 . C:\Users\Eglert\Documents\Elite Software\Fire 6 Project s\ d 63..fiw Wednesday, April 04, 2012,' 10:06 AM RE -1Fire Sprinkler Hydraulics Calculation Program ; Elite Software Development, Inc: lert Gutierrez Design.. EEg Lot 62 and 63 lmm Desert. CA 92211 r Page 5 Fire Sprinkler Output Data :Group A Peak, Node Groupings Output Data Pipe Segment. Pipe Pipe Sprinkler Flow Non -Sprinkler Flow • Beg. Node Imbalance Beg. End. Type . Flow Rate At Beg. Node Out (+) In (-)' Residual Flow At Beg:' ' Node Node Group (gpm) (gpm) (gpm) _. (gpm) Pressure (psi) Node (gpm) 10 20 0 -14.70 - 14:70 - 0.00 0.00 9.00 20 10 0 14.70 0.00 0.00 0.00 - 9.10 0.00000 20 40 0 -14.70 . 30 -.40 0 -14.88 14.88 0.00~ 0.00 9.22. 0.00000 40 20 0 14.70 0.00 0.00 0.00 9.31 0.00000 40 30 0 14.88 .40 50 0 -29.58 " 50 40 0 .29.58 0.00 0.00 0.00 10.48 , 0.00000 50 60 0 -29.58 ` 60 50 0 ' _ 29.58 0.00 .0.00 0.00 9.33 0.00000 60 70 0 -29.58 - 70 60 0 29.58 - . 0.00 0.00 0.00 10.32 0.00000 70 80 0 -29.58 ` 80 70 0 29.58 0.00 '0.00 ► 0.00 -13.76. 0.00000 80 90 0 -29.58 90 80 .' 0 29.58 0.00 0.00_ 0.00 1.3.81 0.00000 90 100 ` 0 -29.58 100 90" 0 29.58 : 0.00 0.00 -29.58 15.94 t C:\UserslEglertlDocuments\Elite Software\Fire 6 Projects\ d 63..fiw Wednesday, April 04, 2012,10:06 AM Sprinkler— Hid raulics Calculation Program ;, Elite Software Development, Inca ' 'errez 0esign . Ort..CA _ Lot 62 and 63 e 92211 • Page 6 Fire Sprinkler Output Data I.Group A Peak Pipe Output Data Beg., Nodal Spk/Hose 'Residual Nom.•Dia. q (gpm) F. L./ft - Pipe -Len. PF-(psi) End. Elevation KFactor Discharge Pressure Inside Dia. Q (gpm) (psi/ft) Fit -Len. PE -(psi) Node (feet) (gpm) (psi) C-Value Velocity Fittings Tot -Len: PT-(psi)'- (fps) Type -Grp (ft) 10 4.90 10.00 14.70 9.00 1.00 14.70 0.03718 2.79 . ' 0.104 20 10.00 10.00 0.00 9.10 . 1.109 ' 14.70 -=-- 0.00 0.000 . CPVC SDR 13.6 150 4.88 -0 2.79 0.104 20. ; 0.00 10.00 0.00 9.10 ,1.25 0.00 0.01195 _17.25 0.206 40 0.00 10.00 0.00 9.31 1.400, 14.7or 0.06 0.000 CPVC SDR 13.5 150 3.06 0 17.25 0.206 30 4.90 10.00 • - 14.88 9.22 1.00 14.88 •0.03801 2.37 0.090 40 0.00 10.00 0.00 9.31 1.109 14.88 --- 0.00 0.000' CPVC SDR 13.5 150 4.94 0 .2.37 . ' .0.090 40 0.00' 10.00 0.00 9.31 1.25 0.00 -0.04357 . 26.75 1.166 50 0.00 10.00 . 0.00 10.48 1.400 29.58. - - 0.00 0.000 CPVC SDR 13.5 150 6.16 0 26.75 1.166 50 0.00 .10.00- 0.00 10.48 1.25 Om. 0.04357 23.50 1.024 60 0.00 15.00 0.00 9.33 1.400 29:58 --- 0.00 . -2.165 CPVC SDR 13.5 150 6.16 . 0 .23.50 =1.141 60 0.00 15.00 0.00 • 9.33 1.25 0.00 ' 0:04357 .22.62 0.986 70 0.00 - 15.00 0.00. 10.32 . 1.400 29.58 ' 7---- 0.00 0.000 CPVC SDR 13.5 150 6.16 0 22.62 0.986 70 0.00 15.00 0.00 • .10.32 1.25 0.00 0.04357 29.33 . 1.278 80 0.00 10.00 0.00 13.76 1.400 29.58 ---: = 0.00 2.165 CPVC SDR 13.5 150 6.16 0 ' _ 29.33 3.443 80 0.00 10.00 0.00 •13.76 1.25: 0.00 0.04357 10.92 • 0.476 90 0.00 ' 11.00 ' 0.00 13.81 '1.400 . 29.58 - . 0.00 -0.433 CPVC SDR 13.5 .150 6.16. - 0 10.92 0.043 90 0.00 11.00 '0.00 113.81 1.25 0.00 0.04357 •49.00 2.136 100 0.00 1.1.00 0.00 15.94 1.400 29.58 ----- -0.00 0.000 CPVC SDR 13.5 �' 150 6.16 0 49.00 2.135 C:\Users\Egl6rt\Documents\Elite Software\Fire'6 Projects d 63..fiw Wednesday; April 04, 2012, 10:06 AM r - Fire Sprinkler. Hydraulics Calculation Program 7 Elite. Software Development,anc. 1FIRE Eg16rt,Gptierrei Design r ._ Lot 62 and 63 Palm'Desert, CA ° 92211. Page 7 Fire Sprinkler Output Data Group A Peak Sprinkler Output Data Flowing Area Group Sprinkler' Sprinkler Residual Area Flowing Sprinkler ` -Sprinkler. Code - �KFactor (K) Elevation Pressure .Flowing (ft2) Density Discharge Node No. (feet) . (psi) (gpm/ft2) (gpm) 10 A 4.90 10.00 9.00 256.00 0.057 14.70 30 'A 4.90 '10.00 , 9.22 - 256.00 0.058 14.88 Sub Totals For Group A 512.00 0.058 29.58 Totals For All Groups 512.00 0.058 29.58 C:\Users\Eglert\Documents\Elite Software\Fire 6 Project nd 63..fiw Wednesday, April 04, 2612, 10:06 AM = Fre Sprinkler Hydraulics Calculation Program ! Elite Software Development, -Inc. [FIRE E lert G tierrez Desig n , g N Lot 62 and 63 - Palm Desert, CA 92211 - 'r,C..J, r - " Page 8 Fire Sprinkler Output Summary - • . Hydraulically Most Demanding Sprinkler Node HMD Sprinkler•Node Number: 10 ' HMD Actual Residual Pressure: 9.00 psi ` HMD Actual GPM: - a 14.70 gpm, Sprinkler Summary Sprinkler System Type: ' . Wet Specified Area Of Application:. 196.00 f:2 Minimum Desired Density:, 0.050 gpm/ftz Application Average Density:' k 0.151 gpm/ft2 Application Average Area Per Sprinkler: 98.00 - f:2 Sprinkler Flow: 29.58 gpm Average Sprinkler Flow: 14.79 gpm y r Flow Velocity -And Imbalance Summary Maximum Flow Velocity ( In Pipe 60 - 70) 6.16 ft/sec _ Maximum Velocity Pressure ( In Pipe 60 - 70) , . 0.26 psi Allowable Maximum Nodal Pressure Imbalance: 0.0000 psi • -Actual Maximum Nodal Pressure Imbalance: 0.0000 psi ' Actual Average Nodal Pressure Imbalance: 0.0000 psi Actual Maximum Nodal Flow Imbalance: - 0.0000 gpm Actual Average Nodal Flow Imbalance: 0.0000 gpm Overall Network Summary' Number,Of Unique Pipe Sections: 9 Number Of Flowing Sprinklers: ° 2 - Pipe System Water Volume: 14.60 'gal Sprinkler Flow: 29.58 gpm ' Non -Sprinkler Flow:. ' 0.00 gpm Minimum Required Residual Pressure At System Inflow r .15.94 Node: psi Demand Flow At System Inflow Node: • 29.58 • gpm C:\Users\Eglert\Documents\Elite Software\Fire 6 Project nd 63..fiw Wednesday, April 04, 2012, 10:06 AM • C:\Users\Eglert\Documents\Elite Software\Fire 6 Projec and 63..fiw ` FIRE - Fire Si rinkler.Hydraullcs Calculation Program Elite Software Development,- Inc. Eglert Gutierrei Design:'Lot 62 and 63 Palm Desert, CA 92211 'Page 9 Fire Sprinkler Output' Data - Hydraulic Supply/Demand. Graph 200 180 160 - 140 L 12000 100 80 60 40 20 0 1 2 3 4 5 6 7 8 9 10 . Flowrate(x100) gpm Supply Curve Data Static Pressure: 112 psi . Test Residual Pressure: 85 psi Test Flow Rate: 784 gpm Demand Curve Data Calculated Residual Pressure: 15.94 psi - Calculated Flow Rate: 29.58 gpm ; Excess Available Residual Pressure At Calculated- Flow: 96 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow' 0.00 psi - Wednesday, April 04, 2012, 10:06 AM ICC-ES Evaluation -Report ESR-2316* Issued April 1, 2009 This report is subject to re-examination in one year. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A.Subsidiary of the Intemational Code Council® DIVISION: 10 00 00—SPECIALTIES Section: 10 31 00—Manufactured Fireplaces REPORT HOLDER: EARTHCORE INDUSTRIES, LLC 6899 PHILLIPS INDUSTRIAL BOULEVARD JACKSONVILLE, FLORIDA 32256 (904) 363-3417 www.isokem.net EVALUATION SUBJECT: Earthcore mortar, supplied with the units, to form a solid - fuel -burning fireplace and chimney system. The refractory • parts are manufactured using a proprietary mixture of volcanic pumice aggregate and aluminate cement. The firebox, smoke dome and chimney outer casing are manufactured with medium -density material, and the flue liner - with high -density material. High -temperature refractory firebricks, a minimum of 1t/6 inches (28.6 mm) thick, are provided to line the interior of the firebox. The firebox is available in sizes noted in Table 2. See Figures 1, 3 and 4 for further details. ISOKERN STANDARD MODELS 36-INCH, 42-INCH AND 46-INCH FIREPLACE AND CHIMNEY SYSTEMS; ISOKERN MAGNUM FIREPLACE SERIES MODELS 36, 42, 48, 60 AND 72; ISOKERN FIREPLACE WITH FIRE- LITE APPLICATION; MODELS VF-36, VF-42, AND VF-46 UNVENTED GAS APPLIANCE ENCLOSURES; AND MODELS IBV-36, IBV-42, AND IBV-46 VENTED GAS APPLIANCE ENCLOSURES 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2006 Intemationa/ Building Code® (IBC T ■ 2006 Intemationa) �.nl-ial o ® c* QUIN 1 ■ 2006Intemational ecOl�l(C �(&M9PFEV KEPT- ■ 2006 International el ��/8�'��j( O v ED Properties evaluated: /'�r 'ONS-(RUCTION ■ Fire resistance FOR C 4 ■ Seismic resistance �� gY _q*_— 2.0 USES DA 12-- 1A-(e The Isokem fireplaces are wood -burning or gas -burning / fireplaces that are constructed , in the field using prefabricated cementitious blocks. 3.0 DESCRIPTION 3.1 Solid-fuel-buming Fireplaces: Isokem Standard Models 36-Inch, 42-Inch, and 46-Inch with DM Chimney; and Magnum Fireplace Series Models 36, 42, 48, 60 and 72 with DM54 Chimney: Isokern fireplaces and DM54 chimney systems are modular refractory units designed for field assembly. The units consist of interlocking precast parts that are fitted together in the field using a premixed mortar called 3.2 Fire-Lite Systems: 3.2.1 General: The Fire-Lite systems consist of Standard Models 36-inch, 42-inch, and 46-inch fireplaces and Magnum Series Models 36-inch, 42-inch and. 48-inch fireplaces, described in Section 3.1,- and a factory -built chimney. All conditions of fireplace manufacture and installation noted in Section 3.1 apply, except as noted in Section 3.2.2. 3.2.2 Factory -built Chimney: A listed and labeled FTF- 13 Class A factory -built chimney is used with the fireplaces, subject to the following requirements: The factory -built chimney is listed by an approved agency for compliance with the requirements of UL 103 for continuous use at 1000°F (537°C) and intermittent use at 1700°F (927°C). 2. The factory -built chimney is for use only with an open combustion chamber and must- be marked "Residential Type and Building Heating Appliance Chimney." a._ The chimney is either solid -pack insulated, a combination of insulation and air space, or noninsulated, completely thermal siphoning, double - wall air-cooled. 4. Listed chimney liners conforming' to the 1700OF (927°C) requirements of UL 1777, ULC S635, or ULC S640 may be used. 5. Chimneys and chimney liners must be installed and terminated in accordance with the manufacturer's installation instructions and under the terms of the manufacturer's listing for use with open-faced, masonry fireplaces. 6. A minimum.2-inch (51 mm) clearance to combustible construction and 3-inch ( mm) clearance to insulation is maintained. "Revised March 2012 APR 05 2012 ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any otlier allHbutes not spec{Jically addressed, nor are as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC ej to arty finding or other matter in this report, or as to any product covered by the report. Copyright © 2012 Page 1 of 6 ESR-2316 I Most Widely Accepted and Trusted Page 2 of 6 3.3 Models VF-36, VF-42, and VF-46 Unvented Gas 4.0 DESIGN AND INSTALLATION Appliance Enclosures: 4.1 General: The enclosures consist of materials similar to those used for the Isokem solid -fuel -burning fireplaces. The enclosures are recognized as complying with ANSI Z21.91 and are for use with unvented decorative gas logs listed and labeled as complying with ANSI Z21.11.2, and having a maximum heat input of 40,000 Btu/h (11 700 W). The gas logs must be factory -equipped with a listed oxygen - depletion safety shutoff system (ODS) and must comply with IFGC Section 620.6. The enclosure must only be installed within a room that has a primary source of heat, and use of the units is prohibited in locations defined in IRC Section G2406.2 and IFGC Section 303.3. Combustion air must be provided in accordance with IRC Section M1702 and IFGC Section 621.5. The room in which the units are installed must have a free -air volume equal to or greater than 50 cubic feet per 1000 Btu/h (4.8 m3/kW) of the aggregate input rating of all appliances within the room. The base, sides, rear and top of the firebox consist of preformed refractory components that interlock together to form the enclosure. Assembly of the firebox is as described in Section 4.1 of this report, except that a 1/2-inch-wide (12.7 mm) mortar joint is used; and 1 1/8-inch-thick (28.6 mm) (minimum) refractory firebrick, conforming to ASTM C1261, is used to line the hearth, side walls and back wall. The unit must be anchored in accordance with IRC Section M1307.2 and IFGC Section 301.12. The firebox is illustrated and dimensions are noted in Figure 2. The firebox may be installed on combustible construction when installed as described in Section 4.1, and at zero clearance to combustible construction on sides, back and top. Minimum clearances are 151/2 inches (394 mm) to side walls, 42 inches (1067 mm) to ceilings and 12 inches (305 mm) to combustible mantles. 3.4 Model IBV-36, IBV-42 and IBV-46 Vented Gas Appliance Enclosures: 3.4.1 General: The system is as described in Section 3.3, except that decorative gas logs listed in accordance with ANSI Z 21.60 are provided with the enclosures for connection to listed gas vents as described in Section 3.4.2. 3.4.2 Gas Vent: The gas vent system consists of a nominally 10-inch-diameter (254 mm), Type B gas vent complying with Chapter 8 of the IMC and Chapter 5 of the IFGC. 3.5 Factory -built Chimney: The firebox units, described in this report, may be used in conjunction with factory -built chimneys listed and labeled as complying with UL103, and must be used with one in Seismic Design Categories D, E, and F. The factory -built chimneys must comply with Type HT requirements of UL 103 and be marked "Type HT and "Residential Type and Building Heating Appliances." The chimneys are limited to a maximum height of 80 feet (24380 mm) and a minimum height of 14 feet (4270 mm); except that where offsets are used, the minimum height is 17 feet (5180 mm). The maximum number of offsets is two. 3.6 Grout and Mortar: Grout used in construction of the fireplace unit is Quickcrete Concrete Mix #1001, 4000 psi concrete mix or equivalent. Mortar used with the fireplace unit is Earthcore mortar. The fireplaces must be installed in accordance with this report, the manufacturer's instructions and the applicable code. A copy of the manufacturer's published instructions must be available at the jobsite at all times during installation. The fireplaces are not recognized for use with doors. 4.2 Design: Installation is limited to Seismic Design Categories A and B, except that when installation is in accordance with Section 4.3 of this report, the fireplaces may be installed in Seismic Design Categories C, D, E and F, provided the seismic design factors are limited to the values noted in Table 1. The seismic design must be in accordance with Sections 15.3.2 (1) and 13.3, 13.4, 13.5 and 13.6 of ASCE 7. Fireplace systems used in Seismic Design Categories C, D, E, and F are limited to those incorporating listed and labeled factory -built chimneys. Structural design calculations and construction plans prepared by a licensed design professional are required to determine the requirements for the fireplace foundation and anchorage of the fireplace to the foundation. When installation is on wood floor construction, the licensed design professional must determine the requirements for support and anchorage for the combined gravity and seismic loading. The applicability of the seismic design parameters in Table 1 must be verified with due consideration of the flexibility of anchorage and supports. In addition, the calculated long-term deflection of the wood members supporting the fireplace must not exceed the values shown in IBC Table 1604.3 for floor members. Under the IRC, an engineered design must be provided in accordance with IRC Section R301.1.3. 4.3 Installation: 4.3.1 General: A noncombustible foundation, adequate to support all required loads, is necessary and must be approved by the building inspector. Fire-Lite Series and (Models IBV-36, IBV-42 and IBV-46 Vented Gas Appliance Enclosure units and Models VF-36, VF-42 and VF-46 may be installed on combustible systems. For combustible supporting systems, installation of a 3-inch-thick (76 mm) Earthcore base plate is required before placement of the firebox hearth components. The Fire-Lite system firebox is assembled following the manufacturer's published instructions. Anchorage of the fireplace unit to the foundation or supporting floor must be designed as described in Section 4.2. Units are assembled on the foundation by installing the base plate, firebox wall sections, damper assembly and smoke dome. Earthcore Mortar is mixed with water until smooth and without dry spots, and is then poured into the supplied Earthcore application bag and applied to one adjoining component face of each joint. A 1/2-inch-wide (12.7 mm) line of mortar is applied'/2 inch (12.7 mm) from all edges of the face with two longitudinal lines between. Mortar must be exposed at the joints when components are joined, and the excess must be smoothed out. The firebox hearth, side walls and back wall are then lined with approved refractory bricks a minimum of 11/8 inches (28.6 mm) thick, except for the Magnum Models 60 and 72, which require minimum 4-inch-thick (101.6 mm) approved refractory bricks, complying with ASTM C27 or ASTM C1261, at the side walls using a refractory mortar, complying with ASTM C199, recommended by Earthcore Industries, LLC. ESR-2316 I Most Widely Accepted and Trusted Page 3 of 6 4.3.2 Clearances: Minimum clearances from the fireplace opening to side walls and ceilings are 24 inches (610 mm) and 61 inches (1549 mm), respectively. Sheathing and trim must be kept at least 8 inches (203 mm) from the opening. Combustible mantles must be at least 12 inches (305 mm) above the opening. A noncombustible hearth extension is necessary and must extend a minimum of 20 inches (508 mm) in front and 12 inches (305 mm) beyond each side of the fireplace opening. For the Magnum Series Models 60 and 72, minimum clearances from the fireplace opening to side walls and ceilings are 48 inches (305 mm) and 61 inches (1549 mm), respectively. Sheathing and trim must be kept at least 9 inches (228 mm) from the opening. Combustible mantles must be at least 38 inches (965 mm) above the opening. A noncombustible hearth extension is necessary and must extend a minimum of 33 inches (838 mm) in front of and 12 inches (305 mm) beyond each side of the fireplace opening. 4.3.3 DM54 Chimney Systems: The DM54 chimney system must be supported from the top plate of the smoke dome. The chimney is assembled starting with a 6-inch- high (152 mm) liner that offsets the joints in the octagonal inner Earthcore liner from those in the square outer chimney casing. The mortar mix is applied in all joints as previously described. The outer chimney blocks have provisions for installation of reinforcing bars. Chimneys may include offsets with a maximum horizontal distance of 6 feet (1829 mm) which is 24 offset blocks in sequence. The offset blocks are supplied by Earthcore Industries, LLC, and are illustrated in Figure 1. The fourth and sixth offset blocks and every third block thereafter must be supported by a concrete block support wall. Where required by the code official, details of the support wall construction must be provided. The portion of the chimney exposed to the exterior must be covered with weather protection material such as exterior plaster or brick veneer, in accordance with the applicable code. Terminations must comply with Sections 716 and 2113.9 of the IBC and Sections R602.8, R1001.6 and R1001.16 of the IRC. Where required by the code official, an approved spark arrester complying with Section 2113.9.1 of the IBC must be used. For installations with vertical chimneys, the fireplace and chimney may be installed with zero clearance to combustibles11 except that the Magnum series units require a minimum 1 /2-inch (38 mm) clearance on the sides and back of the firebox and smoke chamber. When offset blocks are used, the system must be installed with minimum 11/2-inch (38 mm) clearance on the sides and back of the firebox and smoke chamber, and with zero clearance on the top; the chimney is installed at zero clearance to combustibles. 4.3.4 Gas Vent Installation: Gas vents are installed through a 10-inch-diameter (254 mm) hole cut into the top plate of the fireplace enclosure, centered from each edge. The Isokem Anchor Plate/Downdraft Diverter component is placed over the hole using either a bed of Earthcore mortar, or an approved ceramic blanket gasket. The Anchor Plate/Downdraft Diverter hood component is then secured to the top plate using masonry screws. The Type B gas vent must be connected to the Anchor Plate/Downdraft Diverter component and installed in accordance with the vent manufacturer's instructions. 5.0 CONDITION OF USE The Isokern fireplaces and chimney systems described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The fireplaces must be installed in accordance with this report and the manufacturer's published installation instructions. In the event of a conflict between this report and the manufacturer's instructions, this report governs. 5.2 The fireplace units must be installed by contractors approved by Earthcore Industries, LLC. 5.3 Structural design and calculations from a registered design professional must be provided to the code official to justify the supporting structure for all applicable loads, including gravity, wind and earthquake loading, and applicable load combinations per IBC Section 1605. 5.4 An analysis shall be provided to the code official establishing that the seismic conditions for the installation site do not exceed the specified seismic limitations. 5.5 The fireplaces must not be installed with doors. 5.6 The fireplace units are manufactured in Chesapeake, Virginia, and Karup, Denmark, under a quality control program with inspections by Intertek Testing Services NA Ltd. (AA-647). 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Field -constructed Fireplace Systems Using Prefabricated Blocks (AC375), dated February 2012. 7.0 IDENTIFICATION The components of the fireplace and chimney are supplied to the jobsite on shrink-wrapped pallets bearing a label with the Earthcore Industries, LLC, name and address; the product name; the address of the manufacturing plant and the evaluation report number (ESR-2316). A permanent label must be attached to the fireplace and to the vented or unvented enclosure, bearing the Earthcore Industries, LLC, name; the product name; the manufacturing location; the date of manufacture and the serial number, the clearances to combustibles; other information required by UL 127; the inspection agency name (Intertek Testing Services NA Ltd.); and the evaluation report number (ESR-2316). Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/3/2012 t onically Signed at CalCERTS.com by Robert J Pester (Robert John Pester, Architect) 5/3/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 411012012 Project Address Lots 62 & 63 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Flo 4, 705or Area Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST - El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑-No Special Features -- If'Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 3,832 Radiant Barrier New Wall Wood Framed R-21 4,267 1 ew Door Opaque Door None 24 CITYOF LA QUINTA A ew Slab Unheated Slab -on -Grade None 3,933 lerigWWING & SAFETY DEPT. A ew Floor Wood Framed w/Crawl Space R-19 205 ew FOR CONSTRUCTION FENESTRATION U- Exterior-�Z� Orientation A�rea l Factor SHGC Overhan Sidefins Shades �tatus Skylight 7.0 - ; - 0.800 0.39 none none None New Rear`(NM ;� 267.0 }-^--0.530,.m*w*& • 0.46—none..i • e... ,none Sug,Screenyrasb.,,, New Right (NE) f 1 , .' 126.E'0.530 V 0.'46 none ' ,� none ' Bug Screen. New Front (SE) ,j178.8 0.530' 0.46 none - °:' ..rnone- ' ,� Bug Screen' ' ; New M Rear (AIM A. `227.0 11 ,{• 0.530. 0!46 �;•10 0 : none. _ :Bug Screen w�= p New k i Left S ,53�nnone, 'Bu crseen`}t New Rear N 52.6.' _ ,`=` O a.�'�`�� 0.530 � 0.46���none � none Bug Screed_ "' New Right (E) 30.3 " 0.530 0.46 none none Bug Screen New Left (M 45.0 J 0.530 0.46 none none Bug Screen New -J a HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.2 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback . New 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.99 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 1 of 9 Reg: 212-NO0178443-000000000-0000 Registration Date/Time: 2012/04/10 19:44:15 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/3/2012 Electronically Signed at Ca10ERTS.com by Robert J Pester (Robert John Pester; Architect) 5/3/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 .CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1411012012 Date - Project Address Lots 62 & 63 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,705 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ' ® Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. EI Yes ❑ No -Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION `�U- Exterior Orientation . Area , ; Factor SHGC Overhang Sidefins Shades Status .. �,py��_�i,ti +f i ,. ' w� • ■J ,-. �`' ` �� - �,� �;I F� "vy�_ ir�� . �'`r��r!!'� - f � '. �4 �'ew�'-5�3.11 �f ����- S: HVAC SYSTEMS Ot . Heating Min.-Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Pa e 2 of 9 Reg: 212-N0017844B-000000000-0000 Registration Date/Time: 2012/04/10 19:44:15 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/3/2012 Electronically Signed at CalCERTS.Com by Robert J Pester (Robert John Pester, Architect) 5/3/2012 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R Project Name Building Type ® Single Family ❑ Addition Alone Date The Hideaway Lots 62 & 63 ❑ Multi Family' 0 Existing+ Addition/Alteration 4/10/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the s ecial 'ustification and documentation submitted. The DHW System Bradford -White Corp. EF-100T-150-3N is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,043.0 ft' Covered Slab Floor, 3.500" thick at Zone 1 Bedroom 1 & 2 HIGH MASS Design -Verify Thermal Mass: 522.Oft-' Exposed Slab Floor, 3.500" thick at Zone 1 Bedroom 1 & 2 The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify ,Thermal Mass: 159.0 ft' Covered Slab Floor, 3.500" thick at Zone 12 living / Kitchen HIGH MASS Design - Verify Thermal Mass: 977.0 ft' Exposed Slab Floor, 3.500" thick at Zone 12 living /Kitchen The HVAC System HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 249.0 ff' Covered Slab Floor, 3.500" thick at Zone 3 Breakfast / Laundry HIGH MASS Design - Verify Thermal Mass: 610.0 R' Exposed Slab Floor, 3.500" thick at Zone 3 Breakfast/Laundry The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS. Design Verify Thermal Mass �9+1:O ft' Covered'Slib'Floor,-3.500" thick atZone 5 Casita� fry HIGH MASS Design Verify Thermal,Mass 282.0 fl' Exposed Slab Floor, 3.500"thick at Zone 5 Casita 3' - Y p. HERS REQUIRE D VERIFICATION 4f Items in.tft section require field.testingwd/or verification by a,certified HERS Rater. The inspectorAmust receive a completed CF-AR form for each;of.the measures`listed below for final to be given.' The Cooling System Carrier 24APA560158CVX11O includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the orrect Condenser.,.'^ The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 includes credit for verified adequate airflow. -A certified HERS rater must diagnostically measure airflow of the HVAC System. - The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. , The Cooling System Carrier 24APA548158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 includes credit for verified adequate airflow A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA536158CVX070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 3 of 9 Reg: 212-N0017844B-000000000-0000 Registration Date/Time: 2012/04/10 19:44:15 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com ;.5/3/2012 Electronically Signed at Ca10ERTS.com by Robert J Pester (Robert,John Pester, Architect) 5/3/2012 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1411012012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS" �REQUIRE D�yVERIFICAT1OIV _`. ;, � = �--�� 4"�" C` � x � ,� � �r t- Items in thi9 section require field:testing-arid/or verif cation by,a certified'HERS Rater. The'iftpectorxmust receive a com Ieted,CF-4R form for,eacfi of the measures listed;tielow for final to be iven. x ' The Cooling System Carrier 24APA536158CVX070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser: The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA524158CVX070 includes credit for, a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EneravPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 4 of 9 Reg: 212-N0017844B-000000000-0000 Registration Date/Time: 2012/04/10 19:44:15 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/3/2012 Electronically Signed at Ca10ERTS.com by Robert J Pester (Robert John Pester, Architect) 5/3/2012 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date The Hideaway Lots 62 & 63 ❑ Multi Family ❑ Existing+ Addition/Alteration 1411012012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.27 6.01 -0.74 Space Cooling 58.53 52.15 6.38 Fans 12.27 18.27 -5.99 Domestic Hot Water 7.30 3.87 3.42 Pumps 0.00 0.00 0.00 Totals 83,38 80.30 3.07 Percent Better Than Standard: 3.7 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 1,478 179 Fuel Available at Site: Natural Gas (M 1,512 229 Raised Floor Area: 205 (N) 1,426 547 Slab on Grade Area: 3,933 (E) 986 157 Average Ceiling Height: ,., 11.0 Roof 3,839 7 Fenestration Average U-Factor: 0.53 TOTAL: 1,118 Avera a SHGC:`.- 0.46 Fenestration/CFA Ratio: 23.8 i REMARKS -T 7 - �Nlr 44 STATEMENT-OPCOMP,LIANCE - f This certificate of compliance -lists the building features and specifications needed to comply with Title 24, Parts' 1 the Administrative Regulations and Part 6 the Efficiency Standards of'the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 4/10/2012 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code)�� Company BBP Burnell Branch Pester G Address 924 Ana Cape Street Name Bob Pester I City/State/zip Santa Barbara, Ca 93101 Phone (805) 689-3169 Signed V License # Date EnerqvPro 5.1 by EnenqySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 5 of 9 Reg: 212-N0017844B-000000000-0000 Registration Date/Time: 2012/04/10 19:44:15 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS-com - 5/3/2012 Electronically Signed at Ca10ERTS.com by Robert J-Pester (Robert John Pester, Architect) 5/3/2012 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1411012012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Roof 1,558 0.026 R-38 0 20 New . 4.2.1-A9 Zone 1 Bedroom 1 & 2 Wall 191 0.069 R-21 320 90 New 4.3.1-A6 Zone 1 Bedroom 1 & 2 Wall 510 0.069 R-21 50 90 New 4.3.1-A6 Zone 1 Bedroom 1 & 2 Door 241 0.500 None 1 50 90 New 4.5.1-A4 Zone 1 Bedroom 1 & 2 Wall 410 0.069 R-21 140 90 New 4.3.1-A6 Zone 1 Bedroom 1 & 2 Wall 234 0.069 R-21 230 90 New 4.3.1-A6 Zone 1 Bedroom 1 & 2 Slab 1,043 0.730 None 0 180 New 4.4.7-A 1 Zone 1 Bedroom 1 & 2 Slab 522 0.730 None 0 180 New 4.4.7-A1 Zone 1 Bedroom 1 & 2 Roof 864 0.026 R-38 0 20 New 4.2.1-A9 Zone 2 Living/ Kitchen Wall 2411 0.069 R-21 I 1 1 320 90 1 New 4.3.1-A6 Zone 2 Living /Kitchen Wall 60 0.069 R-21 230 90 New 4.3.1-A6 Zone 2 Living / Kitchen Slab 159 0.730 None 0 180 New 4.4.7-A1 Zone 2 Living/ Kitchen Slab 977 0.730 None 0 .180 New 4.4.7-A 1 Zone 2 Living / Kitchen Roof 265 0.026 R-38 0 20 New 4.2.1-A9 Zone 3 Breakfast/Laund Wall 112 0.069 R-21 320 90 New 14.3.1-A6 Zone 3 Breakfast/Laund Wall 430 0.069 R 21 140 80 New 14.3.1-A6 Zone 3 Breakfast/Laund FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status . Glazing Type Location/Comments 1 Skylight 7.0 0.800 NFRC 0.39 NFRC 0 New Double Metal Tinted Skylight Zone 1 Bedroom 1 & 2 2- Window 69.6 '- 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 `3 Window' -� ;,, 25.0 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 4 _ Window 24.4 0.530 NFRC. 0.46 NFRC 50 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 5 t Window,,,;,.;,,;,_ 11.5 0.530 NFRC,,;., .0. 46 NFRC, _.. 501 New-,-._ -Dual Non -Metal Tint-. _.,., •, Zone 1 Bedroom 1 & 2 6 ° Window.'- ; :' 11.5 0.530 NFRC J lo,' 0.46 NFRC .: t-' -150 New Dual Non -Metal Tint A Zone 1 Bedroom 1 & 2 7 Window . ",11.5 0.530 NFRC?Y ' s 0.46 'NFRC 50 New, 'i • , Dual Non -Metal Tint � •L � Zone 1 Bedroom 1 & 2 . 8 Window 10.4 0.530 NFRC ' . " ` 0.46 NFRC 50 New ..Jr. Dual NonWetal Tint . l . ' .. Zone,1 Bedroom,J: & 2 _ 9 Window 10.4 10.530 NFRC ,- , , 0.46 NFRC 'Y 50 New Dual Non -Metal Tint: :..:. �: Zone 1.Bedroom,1,& 2,r-' 10 Window 4,J42.4. ) 0.530 NFRC "Ri 0.46' NFRC A50 New.,44 Dual Non -Metal Tint; Zone .1 Bedroom>l;& 27' 11 WindOWA4 P k 30. 0 -0.530 NFRC , -►r 0. 46 NFRC , • � r 140 New', N.. Dual Non -Metal Tint. +�, ;. Zone N 136dioom" 1 "& 2 12 Window 75.7 r 0.530 NFRC _;: 0.46 NFRC>.•' ,-',dJ40 New _ Dual Non -Metal Tint '- ° ,. _ Zone 1 Bedroom 1 & 2 13 = Window 60.0 • • 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 14, . Window T - 27.0 0.530 NFRC. 0.46 NFRC 320 New Dual Non -Metal Tint Zone 2 Living / Kitchen 15 Window. 200.0 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 2 Living /Kitchen 16 Window 7.7 0. 5301 NFRC 0.46 NFRC 3201 New I Dual Non -Metal Tint Zone 3 Breakfast / Laundry (1) U-Factor Type: '. 116=A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhanq Left Fin Ri ht Fin H t Wd Len I Hcit LExt RExt Dist Len H t Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 IBug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 4.5 6.0 10.0 0.1 10.0 10.0 15 ' Bu Screen 0.76 10.0 ' 20.0 10.0 0.1 10.0 10.0 16 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 6 of 9 Reg: 212-N0017844B-000000000-0000 Registration Date/Time: 2012/04/10 19:44:15 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/3/2012 Electronically Signed at-Ca10ERTS.com by Robert J Pester (Robert John Pester, Architect) 5/3/2012 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 411012012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 420 0.069 R-21 230 90 New 4.3.1-A6 Zone 3 Breakfast/Laund Slab 249 0.730 None 0 180 New 4.4.7-A1 Zone 3 Breakfast/Laund Slab 610 0.730 None 0 180 New 4.4.7-A1 Zone 3 Breakfast /Laund Roof 1 772 0.026 R-38 0 20 New 4.2.1-A9 Zone 4 2nd Floor Wall 235 0.069 R-21 320 90 New 4.3.1-A6 Zone 4 2nd Floor Wall 36 0.069 R-21 50 90 New 4.3.1-A6 Zone 4 2nd Floor Wall 307 0.069 R-21 140 90 New 4.3.1-A6 Zone 4 2nd Floor Wall 325 0.069 R-21 230 90 New 4.3.1-A6 Zone 4 2nd Floor Floor 205 0.037 R-19 0 180 New 4.4.1-A4 Zone 4 2nd Floor Roof 373 0.026 R-38 0 20 New 4.2.1-A9 Zone 5 Casita Wall 99 0.069 R-21 340 90 New 4.3.1-A6 Zone 5 Casita Wall 260 0.069 R-21 70 90 New 4.3.1-A6 Zone 5 Casita Wall 152 0.069 R-21 160 90 New 4.3.1-A6 Zone 5 Casita Wall 2451 0.069 R-21 250 90 New 4.3.1-A6 Zone 5 Casita Slab 91 0.730 None 0 180 New 4.4.7-A1 Zone 5 Casita Slab 1 2821 0.730 None 1 01 180 New 4.4.7-A1 Zone 5 Casita FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 80.0 •• 0. 5301 NFRC 0.46 1 NFRC 320 New Dual Non -Metal Tint Zone 3 Breakfast/Laundry 18 _ Window 22.5 -0.530 NFRC 0.45 NFRC 230 New Dual Non -Metal Tint Zone 3 Breakfast / Laundry 19 Window - 80.0 . 0.530 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 3 Breakfast / Laundry 20 Window 19.4 . 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 4 2nd Floor 21 i I Wndow -, .- 20.3 0.530 NFRC k 0.45, NFRC . 3201 New.,. . Dual No Tint , . Zone 4 2nd Floor 22 Wndow;- - N.45.0 0.530 NFRC ,r NFRC ' -�»320 New 6.,.", Dual Non-Metal-TintA Zone 4 2nd Floor 23 Window .. �' 1.5 0.530 NFRC "4 .. =0.46 INFRC.., 50 New; -" , Dual Non;Metal Tint A = .; Zone 4 2nd Floor 24 Window 1.51 t 0.530. NFRC 1' 0.46 NFRC , 4 50 New ;.+rr Dual Non'Metal Tint ' X Zone,4 2nd Floor -. 25 Window ,1:'5 -0.530 NFRC 0.46 NFRC 1'; 50 New Dual Non -Metal Tint,- : _ ,',. Zone 4 2nd Floor,,; 26 Window 4,1_1.5 y 0.530 NFRC 0.46' NFRC Y" ,140 'New.:.A Dual Non -Metal Tint . '1 Zone-4 2nd Floor 27 Wndowit I<<:.--1:5 A.530 NFRC 0:46 NFRC L z::, ;140 New,., N.4 Dual Non -Metal Tint,%%�� Zone:4 2nd Floor . 28, Window. 1.5 ' 0.530 NFRC 0.46 NFRC,';" 440 New ' ` . Dual Non -Metal Tint " Zone 4 2nd Floor 29 Window.- 4.3 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 4 2nd Floor 30, Window ' 4.3 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 4 2nd Floor 31 Window 9.0 0.530 NFRC 0.45 NFRC 230 New Dual Non -Metal Tint lZone 4 2nd Floor 32 Window 36.0 1, 0. 5301 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint I Zone 4 2nd Floor (1) U-Factor Type: - 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Defauft Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhanq Left Fin Ric ht Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 lBug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 . Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 - 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 1 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 7 of 9 Reg: 212-N0017844B-000000000-0000 Registration Date/Time: 2012/04/10 19:44:15 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/3/2012 Electronically Signed at CalCERTS.com by Robert J Pester (Robert John Pester, Architect) 5/3/2012 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 411012012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation. Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame FENESTRATION SURFACE DETAILS ID Type Area . U-Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 10.0 ' 0.530 NFRC 0.46 1 NFRC 230 New Dual Non -Metal Tint Zone 4 2nd Floor 34 Window 11.5 :0.530 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 4 2nd Floor 35 • Window • -�-'11.5 0.530 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 4 2nd Floor 36 Window 3.1 " 0.530 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 4 2nd Floor 37%- Window_.._-. 52.6 0.530 NFRC-� _0.46 NFRC 3401 News. _. Dual Non -Metal Tinty ,;. _ Zone 5 Casita 38 , Window`-' ` V2.9 0.530 NFRC w k';0.46' NFRC er. «-170 New I!- Dual Non -Metal Tint' f,Ffr Zone 5 Casita 39 Window.; 2.9 0.530 1,NFRC =! ' _ 0.46 'NFRC 70 New r Dual Non -Metal Tirit '• o. t ,' Zone 5 Casita 40 Window 2.9- _0.530. NFRC ,, `' 0.46 NFRC :.4 70 New :a+'F Dual Non'Metal Tint 1 k. ' Zone.5 Casita --�- - 41 Window 221;6 [0.530 NFRC 0.46 NFRC-' 4 70 New Dual Non -Metal. Tint -. , : • Zone 5 Casita 42 Window 4 ,/ 9.0 ,� 0.530 NFRC 0.46 NFRC J. 250 "New.: d Dual Non -Metal Tint) .: - - A Zone 5 CaOall,f? 43 , Windows4 X. Q8.0 -'0.530 NFRC ' �0:46 NFRC '' t:�;250 New' -A-: Dual Non -Metal Tint.,').:�:�+`- - Zone-'5 Casita. tA. 44 Window .. 18.0 0.530 NFRC.-' 0.46 NFRC, z .. -250 New . - Dual Non -Metal Tint ". Zone 5 Casita (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T -116-B ='Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhanq Left Fin Ri ht Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 IBug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 8 of 9 Reg: 212-N0017844B-000000000-0000 Registration Date/Time: 2012/04/10 19:44:15 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/3/2012 Electironically Signed at CalCERTS.com by Robert J Pester (Robert John Pester, Architect) 5/3/2012 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 'CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1411012012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area Volume Year Built New Existing Altered Removed HVAC 1 Zone 1 Bedroom 1 & 2 1,565 17,998 HVAC 2 Zone 12 living / Kitchen 1,136 13,632 HVAC 3 Zone 3 Breakfast / Laundry 859 8,590 HVAC 4 Zone 4 2nd Floor 772 7,720 HVAC 5 Zone 5 Casita 373 3,730 Totals 4,705 0 •0 0 HVAC SYSTEMS ». System Name . Qty., Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 "-. - 1 i Central Furnace 80% AFUE Split Air Conditioner 14.2 SEER Setback New HVAC 2 1 = Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 3- '. 1 Central Furnace-", 80%-AFUE Split,AirCohditioner�arr:-14.5 SEER, Setback New HVAC 4 ',(w- ", 1 , y Centaal Furnace k.' 80% AFUE S -lit, ''Air Conditioner, r 14.5 SEER Setback,-'' New HVAC 5 r,: �` �+►, 1 • Central Furnace u 80/ AFUE Split Air Conditioner -' # 15.5 SEER ^* . . Setback . „ New HVAC DISTRIBUTION f it f. --4'k o'.-! i1. f . = r r 4, -A , 1 -1.F1 4!'/I�' System , „` ' Heatin Coolin Duct Location �� -`~�eDuct1Cv1 R-Value C4- DuctsTIV Tested? Status HVAC 1 - ., Ducted. - Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3, *u . Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 `` Ducted " - Ducted Attic; Ceiling Ins, vented 8.0 m New HVAC 5 'Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS" S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White Corp. EF-1 2 Large Gas All Pipes Ins 150,000 100 0.99 0.00 % 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING . Control Hot Water Piping Length n a ¢ — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. ' HP Plenum Outside Buried ❑. [Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 9 of 9 Reg: 212-N0017844B-000000000-0000 Registration Date/Time: 2012/04/10 19:44:15 HERS Provider: CalCERTS, Inc 7,!,; V, BUILDING ENERGY.ANALYSIS REPORT PROJECT: The Hideaway Lots 62 & 63 A• Lots 62 & 63 - La Quinta, CA 92253 Project Designer: BBP Burnell Branch Pester • 924 Ana Capa Street Santa Barbara, Ca 93101 (805) 689-3169 Report Prepared by: r Jon Scott a Scott Design and Title 24, Inc, C 77-085 Michigan Drive Palm Desert, Ca 92211, ITY OF LA QUINTA (760) 200-4780 ILDING & SAFETY DEPT. FAPPROVED.- FOR (CONSTRUCTION DAT % Po� 12- BY' i;� t2." t, Job Number: Date: 3/30/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2012-03-30T09:10:09 ID: I TABLE OF CONTENTS - I Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 20 Room Heating Peak Loads 25 Room Cooling Peak Loads 30 EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 • C7 • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/30/2012 Project Address Lots 62 & 63 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,705 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 3,832 Radiant Barrier New Wall Wood Framed R-21 4,267 New Door Opaque Door None 24 New Slab Unheated Slab -on -Grade None 3,933 Perim = 365' New Floor Wood Framed w/Crawl Space R-19 205 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Skylight 7.0 0.800 0.39 none none None New Rear (NtM 267.0 0.530 0.46 none none Bug Screen New Right (NE) 126.6 0.530 0.46 none none Bug Screen New Front (SE) 178.8 0.530 0.46 none none Bug Screen New Rear (NW) 227.0 0.530 0.46 10.0 none Bug Screen New Left (SW) 183.6 0.530 0.46 none none Bug Screen New Rear (N) 52.6 0.530 0.46 none none Bug Screen New Right (E) 30.3 0.530 0.46 none none Bug Screen New Left (W 45.0 0.530 0.46 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.2 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.99 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30To9:10:09 ID: Page 3 of 36 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/30/2012 Project Address Lots 62 & 63 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,705 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status rEnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-03-30T09:10:09 ID: Page 4 of 36 • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/30/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White Corp. EF-100T-150-3N is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,043.0 ft2 Covered Slab Floor, 3.500" thick at Zone 1 Bedroom 1 & 2 HIGH MASS Design - Verify Thermal Mass: 522.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 1 Bedroom 1 & 2 The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design -Verify Thermal Mass: 159.0 ft2 Covered Slab Floor, 3.500" thick at Zone 12 living /Kitchen HIGH MASS Design - Verify Thermal Mass: 977.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 12 living / Kitchen The HVAC System HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design -Verily Thermal Mass: 249.0 ft2 Covered Slab Floor, 3.500" thick at Zone 3 Breakfast / Laundry HIGH MASS Design - Verify Thermal Mass: 610.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 3 Breakfast/ Laundry The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 91.0 ft2 Covered Slab Floor, 3.500" thick at Zone 5 Casita HIGH MASS Design - Verify Thermal Mass: 282.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 5 Casita HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA560158CVX110 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA548158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA536158CVX070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 5 of 36 0 • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/30/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA536158CVX070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA524158CVX070 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnerqyPro 5.1 by EnerqySoft User Number: 6712 Run Code: 2012-03-30T09:10:09 ID: Page 6 of 36 • • • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date The Hideaway Lots 62 & 63 ❑ Multi Family ❑ Existing+ Addition/Alteration 3/30/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.27 6.01 -0.74 Space Cooling 58.53 52.15 6.38 Fans 12.27 18.27 a 9 Domestic Hot Water 7.30 3.87 2, Pumps 0.00 0.00 0.00 Totals 83.38 80.30 3.07 Percent Better Than Standard: 3.7 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 1,478 179 Fuel Available at Site: Natural Gas (w) 1,512 229 Raised Floor Area: 205 (N) 1,426 547 Slab on Grade Area: 3,933 (E) 986 157 Average Ceiling Height: 11.0 Roof 3,839 7 Fenestration Average U-Factor: 0.53 TOTAL: 1,118 Average SHGC: 0.46 Fenestration/CFA Ratio: 23.8 % REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 3/30/2012 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company BBP Burnell Branch Pester Address 924 Ana Capa Street Name Bob Pester City/State/Zip Santa Barbara, Ca 93101 Phone (805) 689-3169 Signed License # Date EnergyPro 5.1 by Ene Soft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 7 of 36 • 0 • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type O Single Family ❑ Addition Alone- ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1313012012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Roof 1,558 0.026 R-38 0 20 New 4.2.1-A9 Zone 1 Bedroom 1 & 2 Wall 191 0.069 R-21 320 90 New 4.3.1-A6 Zone 1 Bedroom 1 & 2 Wall 510 0.069 R-21 50 90 New 4.3.1-A6 Zone 1 Bedroom 1 & 2 Door 24 0.500 None 50 90 New 4.5.1-A4 Zone 1 Bedroom 1 & 2 Wall 410 0.069 R-21 140 90 New 4.3.1-A6 Zone 1 Bedroom 1 & 2 Wall 234 0.069 R-21 230 .90 New 4.3.1-A6 Zone 1 Bedroom 1 & 2 Slab 1,043 0.730 None 0 180 New 4.4.7-A1 Zone 1 Bedroom 1 & 2 Slab 522 0.730 None 0 180 New 4.4.7-A1 Zone 1 Bedroom 1 & 2 Roof 864 0.026 R-38 0 20 New 4.2.1-A9 Zone 2 Living/ Kitchen Wall 2411 0.069 R-21 320 90 New 4.3.1-A6 Zone 2 Living/ Kitchen Wall 60 0.069 R-21 230 90 New 4.3.1-A6 Zone 2 Living/Kitchen Slab 159 0.730 None 0 180 New 4.4.7-A1 Zone 2 Living/ Kitchen Slab 977 0.730 None 0 180 New 4.4.7-A1 Zone 2 Living/ Kitchen Roof 265 0.026 R-38 0 20 New 4.2.1-A9 Zone 3 Breakfast/Laund Wall 112 0.069 R-21 320 90 New 4.3.1-A6 lZone 3 Breakfast Laundr Wall 430 0.069 R-21 i 1401 90 New 14.3.1-A6 JZone3Breakfast/ Laund FENESTRATION SURFACE DETAILS ' ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Skylight 7.0 0.800 1 NFRC 0.39 NFRC 0 New Double Metal Tinted Skylight Zone 1 Bedroom 1 & 2 2 Window 69.6 i 0.530 1 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint. Zone 1 Bedroom 1 & 2 3 Window 25.0 0.530 1 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 4 Window 24.4 0.530 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 5 Window 11.5 0.530 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 6 Window 11.5 0.530 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 7 Window . 11.5 0.530 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 8 Window 10.4 0.530 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 9 Window 10.4 0.530 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 10 Window 42.4 0.530 1 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 11 Window 30.0 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 12 Window 75.7 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 13 Window 60.0 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 1 Bedroom 1 & 2 14 Window 27.0 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 2 Living/Kitchen 15 Window 200.0 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 2 Living / Kitchen 16 Window 7.7 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 3 Breakfast/Laundry (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin Ri ht in Hot Wd Len Hot LExt RExt Dist Len Hot Dist Len Hot 1 None 1.00 2 Bug Screen 0.76 3 _ Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Buq Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Buq Screen 0.76 12 Bug Screen 0.76 13 Buq Screen 0.76 14 Bug Screen 0.76 4.5 6.0 10.0 0.1 10.0 10.0 15 Bu Screen 0.76 10.0 20.01 10.01 0.1 10.0 10.0 16 JBug Screen 0.76 T_,myPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 8 of 36 • • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/30/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 420 0.069 R-21 230 90 New 4.3.1-A6 Zone 3 Breakfast/Laundr Slab 249 0.730 None 0 180 New 4.4.7-A1 Zone 3 Breakfast/Laundr Slab 610 0.730 None 0 180 New 4.4.7-A1 Zone 3 Breakfast/Laund Roof 772 0.026 R-38 0 20 New 4.2.1-A9 Zone 4 2nd Floor Wall 235 0.069 R-21 320 90 New 4.3.1-A6 Zone 4 2nd Floor Wall 36 0.069 R-21 50 90 New 4.3.1-A6 Zone 4 2nd Floor Wall 307 0.069 R-21 140 90 New 4.3.1-A6 Zone 4 2nd Floor Wall 325 0.069 R-21 230 90 New 4.3.1-A6 Zone 4 2nd Floor Floor 205 0.037 R-19 0 180 New 4.4.1-A4 Zone 4 2nd Floor Roof 373 0.026 R-38 0 20 New 4.2.1-A9 Zone 5 Casita Wall 99 0.069 R-21 340 90 New 4.3.1-A6 Zone 5 Casita Wall 260 0.069 R-21 70 90 New 4.3.1-A6 Zone 5 Casita Wall 152 0.069 R-21 160 90 New 4.3.1-A6 Zone 5 Casita Wall 245 0.069 R-21 250 90 New 4.3.1-A6 Zone 5 Casita Slab 91 0.730 None 0 180 New 4.4.7-A1 Zone 5 Casita Slab 2F21 0.730 None 0 180 1 New 4.4.7-A1 JZone 5 Casita FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 80.0 0.530 1 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 3 Breakfast/Laundry 18 Window 22.5 0.530 1 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 3 Breakfast / Laundry 19 Window 80.0 0.530 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 3 Laundry 20 Window 19.4 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 4 2nd Floor 21 Window 20.3 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 4 2nd Floor 22 Window 45.0 0.530 NFRC 0.46 NFRC 320 New Dual Non -Metal Tint Zone 4 2nd Floor 23 Window 1.5 0.530 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 4 2nd Floor 24 Window 1.5 0.530 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 4 2nd Floor 25 Window 1.5 0.530 NFRC 0.46 NFRC 50 New Dual Non -Metal Tint Zone 4 2nd Floor 26 Window 1.5 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 4 2nd Floor 27 Window 1.5 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 4 2nd Floor 28 Window 1.5 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 4 2nd Floor 29 Window 4.3 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 4 2nd Floor 30 Window 4.3 0.530 NFRC 0.46 NFRC 140 New Dual Non -Metal Tint Zone 4 2nd Floor 31 Window 1 9.01 0.530 1 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 4 2nd Floor 32 Window 1 36.01 0.530 1 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 4 2nd Floor (1) LI-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len Hat 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 .27 Bug Screen 0.76 28 Bug Screen 0.76 29 Buq Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 Energypro 5.1 by EnerqySoft User Number: 6712 Run Code: 2012-03-30T09:10:09 ID: Page 9 of 36 re • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1313012012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint_ Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame FENESTRATION SURFACE DETAILS ' ID Type Area - U-Factor SHGC;'Azm Status Glazing Type Location/Comments 33 Window 10.0 0.530 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 4 2nd Floor 34 Window 11.5 0.530 NFRC 0.46 NFRC 230 New Dual Non -Metal Tint Zone 4 2nd Floor 35 Window 11.5 0.530 NFRC 0.46 NFRC. 230 New Dual Non -Metal Tint Zone 4 2nd Floor 36 Window 3.1 0.530 NFRC 0.46 NFRC _ 230 New Dual Non -Metal Tint Zone 4 2nd Floor 37 Window 52.6 0.530 NFRC 0.46 NFRC 340 New Dual Non -Metal Tint Zone 5 Casita 38 Window 2.9 0.530 NFRC 0.46 NFRC 70 New - Dual Non -Metal Tint Zone 5 Casita 39 Window 2.9 0.530 NFRC 0.46 NFRC 70 New Dual Non -Metal Tint Zone 5 Casita 40 Window 2.9 0.530 NFRC 0.46 NFRC 70 New Dual Non -Metal Tint Zone 5 Casita 41 Window 21.6 0.530 NFRC 0.46 NFRC 70 New Dual Non -Metal Tint Zone 5 Casita 42 Window 9.0 0.530 NFRC 0.46 NFRC 250 New Dual Non -Metal Tint Zone 5 Casita 43 Window 18.0 0.530 NFRC 0.46 NFRC 250 New Dual Non -Metal Tint Zone 5 Casita 44 Window 18.0 0.530 NFRC 0.46 NFRC 250 New Dual Non -Metal Tint Zone 5 Casita (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len I H t Dist Len. " H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 H Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 10 of 36 • r� • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name The Hideaway Lots 62 & 63 Building Type ®Single Family ❑Addition Alone D Multi Family ❑ Existing+ Addition/Alteration 1313012012 Date BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Existing Altered Removed HVAC 1 Zone 1 Bedroom 1 & 2 1,565 17,998 HVAC 2 Zone 12 living /Kitchen 1,136 13,632 HVAC 3 Zone 3 Breakfast/Laundry 859 8,590 HVAC 4 Zone 4 2nd Floor 772 7,720 HVAC 5 Zone 5 Casita 373 3,730 Totals 4,705 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type__ Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 14.2 SEER Setback New HVAC 2 1 Central Furnace 80 % AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 3 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC 5 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER I Setback New HVAC DISTRIBUTION System Name Heating Cooling Duct Location Duct R-Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 IZI New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New HVAC 4 Ducted I Ducted I Attic, Ceiling Ins, vented 8.01 EI lNew HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 1 8.01 m 1 New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White Corp. EF-1 2 Large Gas All Pipes Ins 150,000 100 0.99 0.00 % 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 m v a — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried D EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 11 of 36 L_A L_I MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name The Hideaway Lots 62 & 63 Date 313012012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incoFporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-611 Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. ' 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. ' 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e ui ed with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Pluin—bing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. - §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. t §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance, and wind. §1506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. I EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 12 of 36 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date The Hideaway Lots 62 & 63 3/30/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. I 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 13 of 36 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date The Hideaway Lots 62 & 63 3/30/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 14 of 36 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date The Hideaway Lots 62 & 63 3/30/2012 System Name Floor Area HVAC 1 1,565 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,540 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent I CFM Sensible Output perSystem 110,000 28,887 3,507 499 26,913 Total Output Btuh 110,000 0 Output Btuh/s ft 70.3 1,361 1,027 Cooling System 0 0 Output perSystem 58,500 0 0 0 0 Total Output Btuh 58,500 0 1,361 1 31,609 3,507 0 Total Output(Tons) 4.9 1,027 Total Output Btuh/s ft 37.4 Total Output s ft/Ton 321.0 1 28,968 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24APA560/58CVX110 40,231 7,061 110,000 Airflow cfm/s ft 1.28 1 110,000 Jan 1 AM Airflow cfm/Ton 410.3 Outside Air % 0.0 % Total Adjusted System Output for Peak Design conditions) I TIME OF SYSTEM PEAK 1 40,231 7,061 Outside Air cfm/s ft 0.001(Adjusted Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 123 OF 123 OF Outside Air 0 cfm Heating Coil Supply Fan 123 OF 2,000 cfm ROOM N 72 OF 72 OF L COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 71/59OF 52/51OF 52/51OF Outside Air Ar 0 cfm Cooling Coil Supply Fan 52 151 OF 2,000 cfm 51.3 41= % ROOM 71 159 OF 91F. 1 4 U:EEJ 4 70 / 59 OF 1 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 /D: Page 15 of 36 a HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Hideaway Lots 62 & 63 Date 3/30/2012 System Name HVAC 2 Floor Area 1,136 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,395 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 25,499 2,765 236 12,999 Total Output Btuh 89,000 0 Output Btuh/s ft 78.3 1,201 496 Cooling System 0 0 Output perSystem 46,500 0 0 0 0 Total Output Btuh 46,500 0 1,201 1 27,902 2,765 0 Total Output ons 3.9 496 Total Output Btuh/s ft 40.9 Total Output s ft/Ton 293.2 13,992 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24APA548/58CVX090 31,643 6,072 89,000 Airflow cfm/s ft 1.41 1 89,000 Jan 1 AM Airflow cfm/Ton 412.9 Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 31,643 6,072 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions r Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 of dw 72 OF 124 OF 124 OF N J Heating Coil Supply Fan 124 OF 1,600 cfm ROOM 72 OF —`-- �► I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air Ar 0 cfm 70 59 OF .4 *1 71 /59°F 52/51 OF 52/51 OF Cooling Coil Supply Fan 53 / 52 OF 1,600 cfm 52.0 % ROOM 70 ! 59 OF fl' = EnergyPro 5.1 by EnergySoli User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 16 of 36 C ` HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Hideaway Lots 62 & 63 Date 3/30/2012 System Name HVAC 3 Floor Area 859 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,312 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 24,656 2,286 244 14,221 Total Output Btuh 71,000 0 Output Btuh/s ft 82.7 1,162 543 Cooling System 0 0 Output per System 35,500 0 0 0 0 Total Output Btuh 35,500 0 2.2861 0 Total Output(Tons) 3.0 1,162 543 Total Output Btuh/s ft 41.3 Total Output s ft/Ton 290.4 1 26,980 1 15,306 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24APA536/58CVX070 24,868 3,823 71,000 Airflow cfm/s ft 1.40 71,000 I Jan 1 AM Airflow cfm/Ton 405.6 Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 24,868 3,823 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air Ar 0 cfm 72 OF 72 OF 127 OF 127 OF f C) 0, Heating Coil Supply Fan 127 OF 1,200 cfm ROOM _ 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 0 cfm 71 / 59 OF 71/59OF 51/51OF 51/51OF Cooling Coil Supply Fan 52 / 51 OF 1,200 cfm � so.s Rio ROOM i 70 / 59 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 /D: Page 17 of 36 r-19 L-1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Hideaway Lots 62 & 63 Date 3/30/2012 System Name HVAC 4 Floor Area 772 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 793 Return Vented Lighting Return Air Ducts Return Fan r Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 15,494 2,135 194 11,326 Total Output Btuh 71,000 0 Output Btuh/s ft 92.0 730 432 Cooling System 0 0 Output perSystem 35,5001 0 0 0 0 Total Output Btuh 35,500 0 730 1 16,954 2,135 0 Total Output(Tons) 3.0 432 Total Output Btuh/s ft 46.0 Total Output s ft/Ton 261.0 12,191 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24APA536/58CVX070 24,899 3,644 71,000 Airflow cfm/s ft 1.55 71,000 Jan 1 AM Airflow cfm/ron 405.6 Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 1 24,899 3,644 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 127 °F 127 °F G Heating Coil Supply Fan 127 OF 1,200 cfm ROOM_ M 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air Ar 0 cfm 71 / 59 OF 71 / 59 OF 51 / 50 OF 51 / 50 OF © - Cooling Coil Supply Fan 52 / 50 OF 1,200 cfm � 50.0 % ROOM 701 58 OF EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-03-30T09:10:09 ID: Page 18 of 36 C a HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Hideaway Lots 62 & 63 Date 3/30/2012 System Name HVAC 5 Floor Area 373 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 630 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 11,929 1,445 111 9,728 Total Output Btuh 71,000 0 Output Btuh/s ft 190.3 562 371 Cooling System 0 0 Output perSystem 23,500 0 0 0 0 Total Output Btuh 23,500 0 1,445 0 Total Output(Tons) 2.0 562 371 Total Output Btuh/s ft 63.0 Total Output s ft/Ton 190.5 1 13,053 10,471 Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 24APA524/58CVX070 16,263 2,715 71,000 Airflow cfm/s ft 2.14 1 71,000 Jan 1 AM Airflow cfm/Ton 408.5 Outside Air °i° 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 1 16,263 2,715 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 155 OF 155 °F i Heating Coil Supply Fan 155 OF 800 cfm ROOM _ 72 OF —A �— 4 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air A r 0 cfm 71 / 59 of 71l59°F 52/51°F 52/51°F —� 955 9 Cooling Coil Supply Fan 52 / 51 OF 800 cfm 51.0 % ROOM 70 ! 59 OF EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 19 of 36 • • L� ROOM LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 313012012 System Name Floor Area HVAC 1 1,565 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible Zone I Bedroom 1 & 2 Zone 1 Bedroom 1 & 2 1 1 1 1,5401 28,8871 3,507 1,5401 28,8871 3,507 4991 26,913 PAGE TOTAL TOTAL* 1,540 28,887 3,507 .499 26,913 1,540 28,887 3,507 499 26,913 * Total includes ventilation load for zonal systems. EnerqvPro 5.1 bv EnerqySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Pa a 20 of 36 0 0 • I ROOM LOAD SUMMARY 1 The Hideawav Lots 62 & 63 3/30/2012 HVAC 2 1 1,136 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM I Sensible I Latent CFM I Sensible Zone 2 Living/ Kitchen Zone 12living /Kitchen 1 1 1 1,3951 2.5,4991 2,765 1,3951 25,4991 2,7651 2361 12,999 PAGE TOTAL • TOTAL' Total includes ventilation load for zonal systems. EnerqyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-03-30T09:1 1,395 25, 499 2,7651 236 12,999 1.3951 25,499 2,765 236 12,999 Em 0 • • ROOM LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 313012012 System Name Floor Area HVAC 3 859 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name I Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible Zone 3 Breakfast/Laundry I Zone 3 Breakfast /Laund 1 1 1,312 24,656 Z286 1,312 24,656 Z286 244 14,221 PAGE TOTAL TOTAL' 1,312 24,6561 2,2861 244 14,221 1,312 24,656 2,286 244 14,221 Total includes ventilation load for zonal systems. EnerqvPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 22 of 36 • • • ROOM LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 3/30/2012 System Name Floor Area HVAC 4 772 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible Zone 4 2nd Floor I Zone 4 2nd Floor 1 1 7931 15,4941 Z 135 7931 15,4941 2,135 1941 11,326 Total includes PAGE TOTAL TOTAL• 793 15,494 2,135 194 11,326 793 15,494 2,135 194 11,326 M • • • ROOM LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 3/30/2012 System Name Floor Area HVAC 5 373 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name I Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible Zone 5 Casita Zone 5 Casita I 1 1 6301 11,9291 1,445 6301 11,9291 1,445 111 9,728 PAGE TOTAL TOTAL" 630 11,929 1,445 111 9,728 630 11,9291 1,4451 111 9, 728 Total includes ventilation load for zonal systems. EnerqvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2012-03-30T09:10:09 ID: Page 24 of 36 • • • ROOM HEATING PEAK LOADS Project Name The Hideaway Lots 62 & 63 Date 3/30/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Bedroom 1 & 2 Floor Area 1,565.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 of Conduction Area U-Value R-38 Roof(R.38.2x 14.16) 1,558.0 X 0.0260 Double Metal Tinted Skylight 7.0 X 0.8000 R-21 Wall (W.19.2x6.16) 1,345.6 X 0.0690 Dual Non -Metal Tint 382.4 X 0.5300 Wood Door 24.0 X 0.5000 Slab -On -Grade perim = 153.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room Infiltration: 1.00 X 1.064 X 1,565 X 11.50 X 0.375 Schedule Air Sensible Area Ceiling Height ACH Fraction X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr = 1,863 = 258 = 4,271 = 9,323 = 552 = 5,138 = = = = = = = = = = = = = = = = = = = = = = = = 21,405 46 = 5,509 46 46 46 46 46 46 Page Total / 60 ] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 26,913 EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 25 of 36 C3 • ROOM HEATING PEAK LOADS Project Name Date The Hideaway Lots 62 & 63 3/30/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 12 living/Kitchen Time of Peak Jan 1 AM Floor Area 1,136.0 ft2 Outdoor Dry Bulb Temperature 26 of Indoor Dry Bulb Temperature 72 OF Conduction Area U-Value AT OF Btu/hr R-38 Roof(R.38.2x14.16) 864.0 X 0.0260 X 46 = 1,033 R-21 Wall (W.19.2x6.16) 301.0 X 0.0690 X 46 = 955 Dual Non -Metal Tint 227.0 X 0.5300 X 46 = 5,534 Slab -On -Grade perim = 44.0 X 0.7300 X 46 = 1,478 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (`) denote conduction through an interior surface to another room Page Total 9,000 Infiltration:[ 1.00 X 1.064 X 1,136 X 12.00 X 0.360 / 60 ] X 46 = 3,999 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,999 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2012-03-30T09:10:09 ID: Page 26 of 36 • • ROOM HEATING PEAK LOADS Project Name Date The Hideaway Lots 62 & 63 3/30/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 3 Breakfast/Laundry Time of Peak Jan 1 AM Floor Area 859.0 ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U-Value AT OF Btu/hr R-38 Roof(R.38.2x 14.16) 265.0 X 0.0260 X 46 = 317 R-21 Wall (W.19.2x6.16) 961.8 X 0.0690 X 46 = 3,053 Dual Non -Metal Tint 190.2 X 0.5300 X 46 = 4,637 Slab -On -Grade perm = 95.0 X 0.7300 X 46 = 3,190 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 11,197 Infiltration:[ 1.00 X 1.064 X 859 X 10.00 X 0.431 / 60 ] X 46 = 3,024 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,221 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 27 of 36 • • C] ROOM HEATING PEAK LOADS Project Name Date The Hideaway Lots 62 & 63 3/30/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 4 2nd Floor Time of Peak Jan 1 AM Floor Area 772.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U-Value AT OF Btu/hr R-38 Roof(R.38.2x 14.16) 772.0 X 0.0260 X 46 = 923 R-21 Wall (W.19.2x6.16) 902.6 X 0.0690 X 46 = Z865 Dual Non -Metal Tint 183.4 X 0.5300 X 46 = 4,471 R-19 Floor Crawlspace 205.0 X 0.0370 X 46 = 349 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 8,608 Infiltration:[ 1.00 X 1.064 X 772 X 10.00 X 0.431 / 60 ] X 46 = 2,717 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,326 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-03-30T09:10:09 ID: Page 28 of 36 • • C] ROOM HEATING PEAK LOADS Project Name The Hideaway Lots 62 & 63 Date 313012012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 5 Casita Floor Area 373.0 111 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value AT °F 373.0 X 0.0260 X 46 = 756.1 X 0.0690 X 46 = 127.9 X 0.5300 X 46 = perim = 73.0 X 0.7300 X 46 = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = through an interior surface to another room Page Total X 373 X 10.00 X 0.431 / 60 J X 46 Area Ceiling Height ACH AT Btu/hr R-38 Roof(R. 38.2x 14.16) 446 R-21 Wall (W.19.2x6.16) Z400 Dual Non -Metal Tint 3,118 Slab -On -Grade 2,451 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction 8,416 = 1,313 TOTAL HOURLY HEAT LOSS FOR ROOM 9,728 EnergyPro 5.1 by EnergySoff User Number. 6712 RunCode: 2012-03-30T09:10:09 ID: Page 29 of 36 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 1 313012012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Bedroom 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,565.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) Wood Door R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) Orientation (N) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 1,558.0 0.0260 56.0 191.4 0.0690 29.9 509.9 0.0690 29.4 24.0 0.5000 29.4 410.3 0.0690 30.4 234.0 0.0690 31.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. f. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fanactratinn Skylight 104-2 L-3 103-4 H-5 H-6 H-7 G-8 G-9 Orientation (N) (NW) (NW) (NE) (NE) (NE) (NE) (NE) (NE) Btu/hr 2,268 395 1,036 353 862 504 1 5,4191 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 30.9 7.0 83.7 0.0 27.7 69.6 42.5 0.0 27.7 25.0 42.5 0.0 27.7 24.4 43.9 0.0 27.7 11.5 43.9 0.0 27.7 11.5 43.9 0.0 27.7 11.5 43.9 0.0 27.7 10.4 43.9 0.0 27.7 10.4 43.91 Page Total Btu/hr 586 2,955 1,062 1,070 504 504 504 456 456 8,098 Internal Gain mu/nr Occupants 4.0 Occupants X 230 Btuh/occ. = LA Equipment 1.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 1.27 X 85.64 X 42 = 4,844 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,887 Latent Gain Btu/hr Occupants 4.0 Occupants X 2001 Btuh/occ. =1 800 Infiltration: 4,771 X 1.27 X 85.64 X 1 2,707 Air Sensible CFM ELA AW HEAT GAIN FOR ROOM L_I • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 3/30/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Bedroom 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,565.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = ' X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 102-10 (NE) 0.0 X 27.7 + 42.4 X 43.9 = 1,859 N-11 (SE) 0.0 X 27.7 + 30.0 X 37.1 = 1,113 101-12 (SE) 0.0 X 27.7 + 75.7 X 37.1 = 2,808 R-13 (SE) 0.0 X 27.7 + 60.0 X 37.1 = 2,226 X + X = X + X = X + X = X + X = X +1 X = Page Total 8,00s Internal Gain Btu/hr Occu ants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 85.64 X 42 = 4,844 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,887 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = Boo Infiltration: 4,771 X 1.27 X 85.64 X 0.00523 = 2,707 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,507 Ene Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2012.03-30T09:10:09 ID: Page 31 of 36 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 313012012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 12 living/Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 1,136.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (N) 864.0 X 0.0260 X 77.0 = 1,730 R-21 Wall (W.19.2x6.16) (NM 241.0 X 0.0690 X 47.3 = 787 R-21 Wall (W.19.2x6.16) (SW) 60.0 X 0.0690 X 52.3 = 217 X X = X X = X X = X X = X X = X X I= Page Total 2,733 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 0-14 (NW) 0.0 X 33.4 + 27.0 X 75.5 = 2,038 10515 (NM 0.0 X 33.4 + 200.0 X 75.5 = 15,093 X + X = X + X = X + X = X + X = X + X = X + X = X +1 X = Page Total 17,130 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,200 Btu = 1,200 Infiltration: 1.064 X 1.27 X 62.16 X 42 = 3,516 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,499 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 1 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 62.16 X 0.00523 = 1,965 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,765 EnergyPro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 32 of 36 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 1 3/30/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 3 Breakfast/Laundry Outdoor Dry Bulb Temperature 112 OF Floor Area 859.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (N) 265.0 X 0.0260 X 77.0 = 531 R-21 Wall (W.19.2x6.16) (NW) 112.3 X 0.0690 X 47.3 = 367 R-21 Wall (W.19.2x6.16) (SE) 430.0 X 0.0690 X 42.4 = 1,259 R-21 Wall (W.19.2x6.16) (SW) 419.5 X 0.0690 X 52.3 = 1,515 X X = X X = X X = X X = X X = Page Total 3,671 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr D-16 (NtM 0.0 X 33.4 + 7.7 X 75.5 = 581 106-17 (NW) 0.0 X 33.4 + 80.0 X 75.5 = 6,037 K-18 (SW) 0.0 X 33.4 + 22.5 X 93.5 = Z 105 106-19 (SW) 0.0 X 33.4 + 80.0 X 93.5 = 7,484 X + X = X + X = X + X = X + X = X +1 X = Page Total 16,206 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = LA Equipment 1.0 Dwelling Unit X 1.200 Btu = Infiltration: 1.Osa X 1.27 X 47.00 X 42 = Z659 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,656 Latent Gain Btu/hr Occupants Occupants X 200 Btuh/occ. 800 Infiltration: 4,771 X 1.27 X 47.00 X 0.00523 = 1,486 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,286 Ene Pro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Pa a 33 of 36 q , j, • C] • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 3/30/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 4 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 772.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Range: 34 OF OlDaaue Surfaces R-38 Roof(R.38.2x 14.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-19 Floor Crawlspace Orientation (N) (NE) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 772.0 0.0260 56.0 235.3 0.0690 29.9 35.5 0.0690 29.4 306.9 0.0690 30.4 324.91 0.0690 31.2 205.0 0.0370 19.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) - Shaded Unshaded Fanactratinn J-20 114-21 Q-22 A-23 A-24 A-25 A-26 A-27 A-28 t7riPntatinn (NW) (N1M (NW) (NE) (NE) (NE) (SE) (SE) (SE) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.01 27.7 19.4 42.5 0.0 27.7 20.3 42.5 0.0 27.7 45.0 42.5 0.0 27.7 1.5 43.9 0.0 27.7 1.5 43.9 0.01 27.7 1.5 43.9 0.0 27.7 1.5 37.1 0.0 27.7 1.5 37.1 0.0 27.7 1.5 37.1 Page Total Btu/hr 1,124 486 72 645 700 144 824 862 1,911 66 66 66 56 56 56 3, 961 Internal Gain Btu/hr Occupants 4•0 Occupants X 230 Btuh/occ. ' Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 1.27 X 42.24 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,494 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 42.24 X 0.00523 = 1,335 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,1351 A ' • • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 3/30/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 4 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 772.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr C-29 (SE) 0.0 X 27.7 + 4.3 X 37.1 = 160 C-30 (SE) 0.0 X 27.7 + 4.3 X 37.1 = 160 E-31 (Sw) 0.0 X 27.7 + 9.0 X 38.6 = 348 P-32 (SW) 0.0 X 27.7 + 36.0 X 38.6 = 1,391 F-33 (St9 0.01 X 27.7 + 10.0 X 38.6 = 386 H-34 (SW) 0.0 X 27.7 + 11.5 X 38.6 = 444 H-35 (SW) 0.0 X 27.7 + 11.5 X 38.6 = 444 U-36 (StM 0.0 X 27.7 + 3.1 X 38.6 = 120 X + X = Page Total 3,453 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 42.24 X 42 = Z389 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,494 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 42.24 X 0.00523 = 1,335 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,135 EnergyPro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Page 35 of 36 • M • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Hideaway Lots 62 & 63 1 313012012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 5 Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 373.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (N) 373.0 X 0.0260 X 56.0 = 543 R-21 Wall (W.19.2x6.16) (N) 99.4 X 0.0690 X 29.0 = 199 R-21 Wall (W.19.2x6.16) (E) 259.7 X 0.0690 X 31.2 = 559 R-21 Wall (W.19.2x6.16) (S) 152.0 X 0.0690 X 28.2 = 296 R-21 Wall (W.19.2x6.16) (W) 245.01 X 0.0690 X 32.1 = 543 X X = X X = X X = X J X I= Page Total 2,140 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr T-37 (N) 0.0 X 27.7 + 52.6 X 42.5 = 2,234 B-38 (E) 0.0 X 27.7 + 2.9 X 49.4 = 143 B-39 (E) 0.0 X 27.7 + 2.9 X 49.4 = 143 B-40 (E) 0.0 X 27.7 + 2.9 X 49.4 = 143 107-41 (E) 0.0 X 27.7 + 21.6 X 49.4 = 1,067 E-42 (W) 0.0 X 27.7 + 9.0 X 53.0 = 477 S-43 (W) 0.0 X 27.7 + 18.0 X 53.0 = 953 S-44 (W) 0.0 X 27.7 + 18.0 X 53.0 = 953 X + X = Page Total 6,114 Internal Gain Btu/hr Occupants 4.Occupants X 230 Btuh/occ. 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 20.41 X 42 = 1,155 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,929 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 20.41 X 0.00523 = 645 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,445 Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2012-03-30T09:10:09 ID: Pa a 36 of 36