Loading...
04-3603 (SFD)Ox 1504 CALLE TAMPICO INTA, CALIFORNIA 92253 BUILDING PERMIT 'BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 Application Number . . . -. 04-00'003603 -__--- Date 6/18/04 • Property Address , ;--80285- VIA CAPRI APN: 772-440-053- - - Application description . . . DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . . . LOW DENSITY RESIDENTIAL Application valuation . . . . 461925 Owner Contractor. ------------------------ ------------------------ VICTOR & CARMEN BACIGALUPI FREEMAN INC, D.L. SPANISH BAY 72880 FRED WARING DR, C13 LA QUINTA CA 92253 PALM DESERT CA 92260 (760) 773-9024 WCC: STATE FUND WC: 2290022647 .01/01/05 CSLB: 706799 05/31/05 CCC: B ------ Structure Information NEW SFD 5126 SQ. FT. ----- Construction Type . . . .. . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/'CONG <=10 Flood Zone . ... . . . . . NON -AO FLOOD ZONE Other struct info . . . ... CODE EDITION 2001 CBC # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 954.00 PATIO SQ FTG . .2184.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 5126.00 ---------------------------------------------------------------------------- Permit . . . BUILDING PERMIT Additional desc Permit Fee . . . . 1679.00 Plan Check Fee 91:35 Issue Date Valuation . . . . 396978 Expiration Date 12/16/04. Qty Unit Charge Per Extension BASE FEE 639.50 297.00 3.5000 THOU BLDG 100,001-500,000 1039.50 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 228.49 Plan Check Fee 57.12 Issue Date Valuation . . . . 0 Expiration Date .12/16/04 �1 P.O. Box 1504 • VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Applicant: Applicant's Mailing Address: c8t� Date: (-?- G/ - a Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my Licens in full force and effect. License Class License No. t Date Z&1= Contractor ; 62414-9--�e-, OWNER-BUILDE ECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (--) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , B.& P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. M rkers' c mpensation insurance tamer n{�nber re Carrier T�}'y(dl Policy Number �o(J Z (p�j7 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall fo with comply with those provisions. Date Applicant ,,,l - t WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERA S UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is,a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lenders Name Lenders Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I hav read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building constructio an ereby authorize representatives of this county to enter upo the above-mentioned property for inspection purposes. Date Signature (Applicant or Agent): 8 i Application Number . . . . . 04-00003603 Page 2 Date 6/18/04 Qty Unit Charge Per _. Extension BASE FEE 15.00 5126.00 .0350 ELEC NEW'RES - 1 OR 2 FAMILY 179'.41 954.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 19.08 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 ---------------------------------------------------------------------------- Permit . . . . . . GRADING PERMIT Additional desc Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/16/04. Qty Unit.Charge Per Extension BASE FEE 15.00 ----------------7----------------------------------------------------------- Permit MECHANICAL Additional desc . . Permit Fee . . . . 215.50 Plan Check Fee 53.,88 Issue Date Valuation . . . . 0 Expiration Date 12/16/04 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 9.0000 EA MECH FURNACE <=100K 45:00 5.00 9.0000 EA MECH B/C <=3HP/100K BTU 45.00 .7.00 6.5000 EA MECH VENT FAN 45.50 10.00 6.5000 EA MECH EXHAUST.HOOD 65.00 ---------------------------------------------------------------------------- Permit PLUMBING Additional desc Permit Fee . . . . 236.25 Plan Check Fee 59.06 Issue Date Valuation . . . 0 Expiration Date 12/16/04 Qty Unit Charge Per. Extension BASE FEE 15.00 25.00 6.0000 EA PLB FIXTURE 150.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 Page 3 Application Number . . . . . 04-00003603 Date 6/18/04 Qty Unit Charge Per Extension 4.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 12.00 13.00 .7500 EA PLB GAS PIPE >=5 9.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments NEW SFD 5126 SQ. FT. PLAN CHECK FEES WAS ADJUSTED FOR $1000 DEP. THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL AND SPA DRIVEWAY APPROACH -------------------------------------------------------------=--------------- Other Fees . . . . . . . . ART IN PUBLIC PLACES -RES 654.81 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 109.14 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE 22.50 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 46.19 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited --------------------------------------------------------- 'Due Permit Fee Total 2374.24 908.65 .00 1465.59 Plan Check Total 261.41 91.35 .00 170.06 Other Fee Total 3237.64 .00 .00 3237.64 Grand Total 5873..29 1000.00 .00 4873.29 Building 80 - a 8 s V//;I`Address Titv/444" oY3603 P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 mailing Address-- Citv f ITel. Co State Lic. City & Classif. <1t7Lic. # Lic. I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that suchimprovements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden o/ proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) 0 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST OCC. GRP. A.P. Number 1 1 Cil 'r Legal Description Project DescriptionC---- Sq. Ft. <-f) Iq / No O No. Dw. Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure A TOTAL REMARKS AMOU if f ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Coachella Valley Unified School District P.O. Box 847, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: _ Owner's Name: Victor & Carmen Bacigalupi Phone No. 275-0926 80-285 Via Capri La Qunta, CA 92253 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: OATF., RFCFIPT' GHRCK N- IMTIAIA' CERTIFICATE OF COMPLIANCE (California Education Code 17620) Date June 21, 2004 Project Address: Project Description: _ APN: 772-440-00? SFD Tract #: Type of Development: Residential XX Commercial Total Square Feet of Building Area: 5,126 sq. ft. Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is]authorized to sign on behalf of the owner/developer. Dated: June 21, 2004 Signature: ************************************************r�********************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Note: Number of Sq.Ft. Amount per Sq.Ft. Amount Collected 5,126 $ 2.68 $ 13,737.68 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Elvira Mattson, Office Technician Signature: Not Subject to Fee NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate of compliance form tables.doc 1/16/03 T 5-20-04; 8:13AM , 1 0 J L V V T V f• J J G L O V 1 S O 1 V r 1 11 FIDELITY NATIONAL TITLE COMPANY StII3DIXIISION DEPARTMENT WHEN RECORDED MAIL TO: Mr: & Mrs_ victor Bacigalupi 80-517 Spanish Bay La Quinta, CA 92253 MAIL TAX STATEMENT TO: SAME AS ABOVE 1JrJn-_vn�__5 ... _. 760 777 9471 ;## f V V fee J T f 1 1 N . 1 DOC " 2003-0,140883 10/24/2003 08:00A Fei:16.00 Page l of 4 Doc T Tax Paid Recorded in official Records County of Riverside Gary L. Orso Assessor, County Clark & Recorder 1111111111111111111111111111113111111111111111 M S V PAGE SRf DA POOP NOCON ' SNF MISC. R _ L copy LONG _MERINO NCHG E%AN DOCUMENT TRANSFER TAX $ (a I L. S J XX Computed on the consideration or value of property conveyed; OR Computed on the consideration or value less liens or encumbrances remaining at the time of sale. Signature of Declarant or Agent determining tax - Firm Name 7i2t - 090 GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QLINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S)to victor Bacigalupi and Carmen Bacigalupi, Husband and Wife as Joint Tenants ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. Dated: July 10, 2003 ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd. an tegnson ability cc its ber By: Authorized Representative 5-20-04; 8:13AM 760 777 9471;# 2 1 IO L V V T V f• JJO LO V 1 SO 1 V r l ! V V f f f JT f 1 s o EXHIIBT "A" Legal Description Parcel No. 1: Lot 16 and 17 of Amended Tract No. 29894-2, in the City of La Quinta, County of Riverside, State of California, as per Map recorded in Book 327, Pages 56 through 88, inclusive of Maps, in the Office of the County Recorder of said County and shown on Grant Deed recorded April 14, 2003 as Instrument No. 2003-260914 of Official Records. Grant Deed reflects Parcel Merger No. 2003-402, as approved by the City of La Quinta. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrument No. 2002- 745939, of Official Records of Riverside County, California (the "Official Records"); 2. The Supplementary Declaration of Annexation of Property, recorded on March 21, 2003, as Instrument No. 2003-201647, of Official Records of Riverside Country, California. FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. FURTHER RESERVING THEREFROM, an easement for landscaping purposes over the Northerly 12' feet thereof. Parcel No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. 5-20-04; 8:13AM - 760 777 9471;41 3 1 10..7 L V V T V f. JJO LOIw 1 SO 1 Ur 1 ! V V f f f JT f 1 r./ . J SUBJECT TO: Non delinquent general, special and supplemental real property taxes and assessments. 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without imitation, the Declaration and the Map for Tract No. 29894-2. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of -the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. RANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor d The Hideaway Owners Association such powers and rights which are set forth in the Decl n definedabove, on _ (3 , 2003. Carmen Bacigalupi STATE OF CA,, cP2 J, A ) ) ss. COUNTY OF �t \/EatS , On �c� . 13 , 2003, before me, the undersigned, a notary public in and or said State, personally appeared Victor Bacigalupi and Carmen Bacigalupi, personally known to me (or proved to me on the basis of satisfactory evidence) to be the persons whose names are subscribed to the within instrument and acknowledged to me that they executed the same in their authorized capacities, and that by their signature on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. Connie Concetto F �. COMM. #1417229 z s NOTARY PUBLIC - CALIFORNIA y t� ate- o�t7e-fie 6�`�` [SEAL] V RIVERSIDECOUNTY Signature My COMMISSIon Expires May 11. 2007 i!. 100, - Certificate of Occupancy O p � w G & Safet De artnt OF Building Y Department This Certificate is issued pursuant to the requirements of Section 909 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 80-285 VIA CAPRI C. Use classification: SINGLE FAMILY DWELLING Building Permit No.: 04-3603 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL DL FREEMAN INC Address: 72-880 FRED WARING DR #C13 City, ST, ZIP: PALM DESERT, CA 92260 By: GARY SHOWALTER Date: OCTOBER 26, 2005 Building Official POST IN A CONSPICUOUS PLACE • s +o . -1 yr ....,••,...y - r . . _ ... .+.• • . .. �,yp•, .-...v'r. +-, +.... - - ,-., r.'+:.,- . .. _N +v MEN 10/27/2005 10:27 ;I 7607739065 D.L.FREEMAN,INC. PAGE 02 I 8 S CITY OF LA QUINTA BUILDING & SAFETY DEPARTMENT Ic�M OF Tl�� 777-7012 INSPECTION REQUEST LINE r- Owner- T A C7/ A T TiT1T i Contractor Permit Number kfl = POST ON J891V. ONSP.IC000S PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS NEW SFD 5121 SQ. FT. THIS PERMIT DOES OT INCLUDE.POOL- AND SPA, BLOCK WALLS AND DRIVEWAY APPROACH. f TYPE OF INSPECTION DATE INV. TEMPORARY POWER SETBACKS I U/G PLUMBING / WASTE —p U/G ELECTRICAL/ GROUNDING FOOTINGS /`STEEL DO NOT -`POUR CONCRETE UNTIL ABOVE SIGNED ROOF NAIL/ PRE-'RWF .5'Ce _ OKAY TO. WRAP FRAMING (COMBINATION) 2 _ ROUGH ELECTRIC ROUGH PLUMBING ROUGH MECHANICAL INSULATION —:-j COVER NO WORK UNTIL AAOVt SIGNED INTERIOR GYP. BD. (DRYWALL)' - EXTERIOR LATH GAS TEST SEPTIC ABANDONMENT SEWER CONNECTION S PTIC / CaRE SE INTERCEPTOR r MASONRY IN,SP5CTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS ..0/G PLUMBING U/G GAS U/G ELECTRICAL - PRE -PLASTER ALARMS / BARRIERS FINAL INSPECTIONS TEMP. USE OF PERMANENT POWER ELECTRICAL PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT. FINAL / JOB COMPLETED ye Aq— ` ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING F-7-— TITLE 24 REPORT f Title 24 Report for: The Bacigalupi Residence 17Y OF Lq Lot #16/17 @The Hideawa BUILDING & SAFE �NTiq La Quinta , CA 92253gppRO DEPT. FOR C�NSTR �E� DA � ,� p ON BY Project Designer: Stephen Jones Design & Construction, Inc. P.O. Drawer 4656 Palm Desert, CA 92261 (760) 346-3366 Report Prepared By: CJ Mcfadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT; CA 92211 (760) 346-0855 Job Number:' Date: - 4/8/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. k . y : EnergyPro 3.1 By EnergySoft Job Number: User Number: 3665 LoT t617 AD'4195 wi ffiftl -COPY Z6of (9L • �. .. t�. ... ,, ,�r. .. .. ,' o .. Certificate of Compliance: Residential (Part 1 of 2), CF -1R The Bacigalupi Residence 4/8/2004 • Project Title Date Lot #16/17 (aD-The Hideaway La Quinta Project Address I . Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/ Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only t� 0 GENERAL INFORMATION Total Conditioned Floor Area: 5,096 ft2 Average Ceiling Height: 10.3 ft Total Conditioned Slab Area: 3,857 ft2 Building Type: Frame Type (check one or more) R-38 Roof (R.38.2x14.16) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 2 ® Raised Floor Component Type Frame Type Const. Assembly U -Value R-38 Roof (R.38.2x14.16) Wood 0.028 R-23 Wall (W.23.2x6.16) Wood 0.051 R-23 Wall (W.23.2x6.16) (W-2) Wood 0.052 Solid Wood Door Wood 0.387 Slab On Grade n/a 0.756 Slab On Grade n/a 0.756 Raised Floor (Stone) Wood 0.030 Raised Floor (Stone) (W-2) Wood 0.029 FENESTRATION Location/Comments (attic, garage, typical, etc.) Exterior Roof Exterior Wall Exterior Wall Exterior Door Exposed Slab w/R-0.0 Perimeter Insulation Covered Slab w/R-0.0 Perimeter Insulation Exterior Floor / Over Open Space Exterior Floor / Over Open Space Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (North) 39.0 0.45 0.34 Bug Screen ❑ X❑ ❑ X❑ Left (East) 39.9 0.45 0.27 Bug Screen ❑ x❑ ❑ x❑ Left (East) 6.3 0.45 0.34 Bug Screen ❑ X❑ ❑ X❑ Rear (South) 275.1 0.38 0.27 Bug Screen ❑ X❑ ❑ X❑ Right (West) 129.2 0.45 0.27 Bug Screen ❑X❑ ❑ _ 91 Front (North) 46.3 0.45 0.27 Bug Screen ❑ X❑ ❑ x❑ Left (East) 103.1 0.38 0.27 Bug Screen ❑ X❑ ❑X❑ Rear (South) 146.2 0.45 0.27 Bug Screen ❑ a ❑ o Front (North) 224.4 0.38 0.27 Bug Screen ❑ X❑ ❑ X❑ Right (West) 246.0 0.38 0.27 Bug Screen ❑ X❑ ❑X❑ ❑ ❑ ❑ ❑ ❑❑ 1:1 El Run Initiation Time: 04/08/04 14:23:28 Run Code: 1081459408 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: Pa e:3 of 37 • • Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Y The Bacigalupi Residence 4/8/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments ('Pntfal Furnnnp 80% AFUE Ducts in Attic 6.0 Setback HVAC -1 (Master Suite) Central Fumace 80% AFUE Ducts in Attic so Setback HVAC 2A & 2R (Living Area) Central Furnace 80% AFUE Ducts in Attic 6.0 Setback HVAC 3A & 3B (Living Area) CPntral FurnarP 80% AFUE Ducts in Attic 6.0 Setback HVAC4 (Guest Suites) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner Split Air Conditioner Split Air Conditioner Split Air Conditioner WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Rheem HE -119-130 Large Gas Standard 1- 130,000 130 0.94 0.0000 0.0 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANGE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Stephen Jones Design & Construction, Inc Address: P.O. Drawer 4656 Palm Desert, CA 92261 Telephone: (760) 346-3366 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Name: CJ Mcfadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 > OA (signatu (d te) (signature/stamp) (date) Run Initiation Time: 04/08/04 14.23.28 Run Codes 1081459408 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: PageA of 37 Certificate of Compliance: Residential (Addendum) CF -1 R The Bacigalupi Residence 4/8/2004 • Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field 49 E The HVAC System "HVAC -1 (Master Suite)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1 (Master Suite)" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -1 (Master Suite)' has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -1 (Master Suite)' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual HIGH MASS Design(see C -2R) - Verify Thermal Mass: 850 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 850 sqft Exposed Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 424 sqft Covered Slab Floor, 3.50" thick at Master Suite The HVAC System "HVAC 2A & 2B (Living Area) " must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC 2A & 2B (Living Area) " has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified The HVAC System "HVAC 2A & 2B (Living Area) " has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified The HVAC System "HVAC 2A & 2B (Living Area) " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 900 sqft Tile in Mortar Interior Mass, 0.75' thick at Downstairs (Living / Dining) HIGH MASS Design(see C -2R) - Verify Thermal Mass: 900 sqft Exposed Slab Floor, 3.50" thick at Downstairs (Living / Dining) HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form GF -6R. plan Field The HVAC System "HVAC -1 (Master Suite)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC 2A & 2B (Living Area) " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rate must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC 3A & 3B (Living Area) " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rate must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC4 (Guest Suites)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 04/08/04 14:23:28 Run Code: 1081459408 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:5 of 37 Certificate of Compliance: Residential (Addendum) CF -1 R The Bacigalupi Residence 4/8/2004 • Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field • HIGH MASS,Design(see C -2R) - Verify Thermal Mass: 74 sqft Covered Slab Floor, 3.50" thick at Downstairs (Living / Dining) The HVAC System "HVAC 3A & 3B (Living Area) " must meet all CEC Criteria for a Zonally Controlled system serving only Living Area. The HVAC System "HVAC 3A & 3B (Living Area) " has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified The HVAC System "HVAC 3A & 3B (Living Area) " has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified The HVAC System "HVAC 3A & 3B (Living Area) " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Mana HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1400 sqft Tile in Mortar Interior Mass, 0.75" thick at ami y i c en m y aun HIGH MASS Design(see C- R) - Verify Thermal Mass: 1400 sqft Exposed Slab Floor, 3.50" thick at Family/Kitchen/Entry/Laundry HIGH MASS Design(see C -2R) - Verify Thermal Mass: 209 sqft Covered Slab Floor, 3.50" thick at Family/Kitchen/Entry/Laundry The HVAC System "HVAC -4 (Guest Suites)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas The HVAC System "HVAC -4 (Guest Suites)" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4 (Guest Suites)" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4 (Guest Suites)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:6 of 37 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R I NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into • the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 10 • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X 1150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturers labeled R -Value. *§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X not apply to exterior mass walls). E]'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑X § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:7 of 37 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: -Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into • the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 11 • • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X❑ 1150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑§114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 3665 Job Number: Page:8 of 37 Computer Method Summary 0 028 395 0 (Part 1 of 3) C -2R JgalupiBesidence _90 Wall_ 50 4/8121 Project Title ect Loni#16L1-7_@�I.e-ideaWay-La_Qujnta Wall_ 307_ -0-0 5J 90 Date Project Address 0.38.7_ 90 20 Building Permit # BREEZEAIRCO_LlDMONING 90 760 346-0855 -0-052- 180 Documentation Author Wall_ X32 Telephone Plan Check/Date Computerese-&rmaace -D-052- -2.Z0_ 15 Field Check/Date Compliance Method (Package or Computer) 0 Climate Zone 0-051 ----0 Source Energy Use Standard Proposed Compliance 90 (kBtu/sf-yr) Design Design Margin Wall- 1.9.6_ Space Heating 4.59 4.35 0.24 -0-028 45 Space Cooling 37.09 28.36 8.73 90 Domestic Hot Water 5.59 3.26 2.33 Wall- 37_1 Totals 47.26 35.97 11.30 0028 395 Percent better than Standard: Wall-119 23.9% 90 Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name .MVAC -1 (MasteLS.uite) _HVAC-2A-&-2B-(Livinglarea) •HVAC_3A - -(Living-Area) _H_VA-CA-(GuesLSuite .) 5,096 ft2 Single Fam Detached (North) 0 deg 1.00 2 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume 1 274 x,284 1.,60.9 929 Solar Gains Y/N _Root 964 0 028 395 0 Wall -X24 -0_051 0 _90 Wall_ 50 -0-052 0 90_ Wall_ 307_ -0-0 5J 90 90 .D.00r --18_ 0.38.7_ 90 20 Wall_ 118 _00.51 1.8.0 90 AAWI 44 -0-052- 180 90 Wall_ X32 3061 370 90 Wall_ X23 -D-052- -2.Z0_ -90- 90Root- Roof 310 0 028_ _34.5_ 0 Wall_ x.29 0-051 ----0 90 Wall_ 177 -0-05-1 90 90 Wall- --131 -0.0.51 X8.0 _90_ Wall- 1.9.6_ 0.051 _2Z0 90 ROoL- 97A -0-028 45 0 Wall -252 -0_051 0 90 Wall_ 54_ _0_0.51 90. 9.0_ Wall- 37_1 -0_051 _189 9.0_ .Roof- 1..22$ 0028 395 -0- 0Wall- Wall-119 -0-05-1- 0 90 Wall_ _233 9..052_ 0 90 .Door 24_ _0.387 0 9.0 Wall- _-487_ -0..0.51 _9.0 9.0 Wall- ---IA3_ _0_0.52 9.0 -90- 90_Door -Door24 _0_387 -90---90 Wall- 2Z7- -0-05-t 180 -90- 0Wall_ Wall-32. --0-052- _189 -90- 0Wall- Wall 21]. -0-05J. -2.7-0 -90- 0Wall- Wall 9 --0-052- -270 90 12,10.5 13,.6.5.7 18.5.0.7 987 Floor Construction Type: FX� Raised Floor ❑X Slab Floor Total Fenestration Area: 24.6% Total Conditioned Volume: 52,255 ft' Total Conditioned Slab Area: 3,857 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area _025_ Sleeping _S1eepingS.tat_ 8 -n/a _025_ Living _I ivingSlat_ 8 -n/a 0-32_ Living Living.Slat_ 8 -n/a 018_ Sleeping -aleepingSlat_ 8 _n/a Form 3 Reference 1i38_Bo oL(R .38.2x1416) _R231W..alL(W23.2x6t6) R231W/al L(W 23.2x6t6.)_(W_2 ) R--3WaII-(W 23 2x616) Solid_W_ _ood400r R231WCaUVV 232x616.) R23Ma1L(W232x6-16)_( W/1) R23- WCalL(WL2.3 2x616) R23_W-all_(W 23 2x616.)_(32)- -R--3.8-Roof-(R 382xL416) R23_Wall nN.23�6_16.) R231WLaIL(W.23 2x616) R-23 Wall (W.23.2x6 16) _&2.3_WaIL(W.23-2x6 ti 6.) R38Rooi (R _38.2x1916 ) R33 WaIL(W23-W t6) R23_Wall_(W 23.2x616) R231WIa1L(W.2.3 2x616) R38Rooi_(R_382x]4t6) R23_WaIL(W 232x616) R23Mall (K2.32x6t6L-2) Solid WoodJ)o_or R231W/alL(W 23 2x616) R23_WaIL(W_23.2x6JB)-(W 2) _Solid Wood Door R23-WalL(W232x6,16) R 23_3 a I L(N_ 2.32 x6-16) _ (W_ 2) R--31WLalL(W23 2x616) .Zone 1 Zone 2A Zone 2A Zone 2A .Zone 2A Zone ?A .Zone -2R .Zone2B .Zone -2B Zone -2R Zone" .Zone -3 Zone -3 Zone_3 Location / Comments Comauter Method Summary (Part 1 of 3) C -2R -The _13.acigalupiRes.idence 4.59 4/812094 *Project Title 1ot #16/17_@TheJffideaway I a-Qu.inta Space Cooling Date Project Address 8.73 Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 2.33 Documentation Author Telephone Plan Check/Date COn1�11te�elfOlmgnr.A 15 30.3_ _0_Q51 --180--90- _80- 90Wall— Field Check/Date Compliance Method (Package or Computer) Climate Zone 351 —0-0 5-t 270-90 Source Energy Use Standard Proposed Compliance a (kBtu/sf-yr) Design Design Margin ❑ Space Heating 4.59 4.35 0.24 Space Cooling 37.09 28.36 8.73 Domestic Hot Water 5.59 3.26 2.33 Totals 47.26 35.97 11.30 Percent better than Standard: 30.3_ _0_Q51 --180--90- _80- 90Wall— Wall 23.9% Total Conditioned Floor Area: 5,096 ft2 Floor Construction Type: ❑X RaisedFloor Slab Floor Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Total Fenestration Area: 24.6% Number of Dwelling Units: 1.00 Total Conditioned Volume: 52,255 ft 3 Number of Stories: 2 Total Conditioned Slab Area: 3,857 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area OPAQUE SURFACES . Act. Type Area Ll -Fac. Azm. Tilt .FJo.or 529 0 030 0 980 .FJoor 5.0 _0_029 0980_ -Roof 929 —0-028- —345 0_ Wall— —290- —0_051 0 _90- 0Wall— Wall- 30 0-052 0 _90- 0Wall_ Wall- _221-0-051 _90 _90 Wall_ x_48--O-Q52- 90 90 Door— • t8 Q.aBZ 90 90 Wall_ 30.3_ _0_Q51 --180--90- _80- 90Wall— Wall 30_ —0-052 9.8.0_ 9.0 Wall— 351 —0-0 5-t 270-90 0 Solar Gains Y / N Form 3 Reference .Zone 4 Location / Comments I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:10 of 37 1 0 _Baised_F1oor (..SSone) ❑ A ❑ Baise_dFJooL(.S.tone.)_(W_2) _EZ3.8_Boof_(8..38_2x1_4.._t6.) ❑ _ _2aAalUW_23.2x6.16) ❑ R-23 WaIL(YSL.232x6_16)�W2) X ❑ R23_WaIL(W232x616) X ❑ R2.3_W_aIL(W Za.WJ6)_(W1) X ❑ Solid_ o:od_D_oor X X ❑ ❑ ❑ R23_V_1LaIL(\L1/232x616.) B23 W lL(z 23.2x616.] (W 2) W lL(W232x616) a R23 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ .Zone 4 Location / Comments I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:10 of 37 1 Computer Method Summary (Part 2 of 3) C -2R The Bacigalupi Residence 4/8/2004 •Project Title Date FENESTRATION SURFACES Ll- Act. Glazing Type Location/ # Tvpe Area Factor SHGC Azm. Tilt Comments ,_ Window-Eront (North) -390 0A50 -0_34- (L _90 Weather -Shield -Glazing 2 Window Left (East) 4.0 0.450 0.27 90 90 Weather Shield Glazing 3 Window Left (East) 6.3 0.450 0.34 90 90 Weather Shield Glazing 4 Window Rear (South) 48.0 0.380 0.27 180 90 Weather Shield Glazinq 5 Window Right (West) 15.0 0.450 0.27 270 90 Weather Shield Glazing 6 Window Right West 22.5 0.450 0.27 270 90 Weather Shield Glazing 7 Window Right (West)_ 4.0 0.450 0.27 270 90 Weather Shield Glazing 8 Window Right (West) 4.0 0.450 0.27 270 90 Weather Shield Glazing 2 Window Right (West). 6.3 0,450 0.27 270 90 Weather Shield Glazing 10_ Window Front (North) 21.3 0.450 0.27 0 90 Weather Shield Glazing 11 Window Left (East) 40.0 0.380 0.27 90 90 Weather Shield Glazing 12 Window Rear South 4.0 0.450 0.27 180 90 Weather Shield Glazing 13 Window Bight (\Melt)_ _2.1.3 0.450 0.27 270_ -9Q Weather Shield -Glazing 14 Window Front (North) 60.0 0.380 0.27 0 90 Weather Shield Glazing 15 Window Front (North) 60.0 0.380 0.27 0 90 Weather Shield Glazing 16 Window Front North _ 60.0 0.380 0.27 0 90 Weather Shield Glazing 17 Window Rear South 60.0 0.380 0.27 180 90 Weather Shield Glazing 18 Window Rear (South) 60.0 0.450 0.27 180 90 Weather Shield Glazing 1R Window Rear (South) 60.0 0.450 0.27 180 90 Weather Shield Glazing 20 Window Rear South 4.0 0.450 0.27 180 90 Weather Shield Glazing 21 Window Front North 21.0 0.450 0.27 0 90 Weather Shield Glazing .22. Window Left (East) 20.5 0.380 0.27 90 90 Weather Shield Glazing 23 Window Left (East) 20.0 0.450 0.27 90 90 Weather Shield Glazing 24 Window Left East 42.6 0.380 0.27 90 90 Weather Shield Glazing 25 Window Rear South 150.0 0.380 0.27 180 90 Weather Shield Glazing 26 Window Right (Westj 150.0 0.380 0.27 270 90 Weather Shield Glazing 27 Window Right (West) 48.0 0.380 0.27 270 90 Weather Shield Glazing Window Right (West) 48.0 0.380 0.27 270 90 Weather Shield Glazing •28 29 Window Front (North) 17.1 0.380 0.27 0 90 Weather Shield Glazing INTERIOR AND EXTERIOR SHADING Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 2A Zone 2A Zone 2A 2w e2A Zone 2B Zone 2B Zone 2B Zone 2B Zone 2B Zone 2B Zone 2B Zone 3 Zone 3 Zone 3 Zone 3 Zone 3 Zone 3 Zone 3 Zone 3 Zone 4 Window Overhang Left Fin Right Fin # Exterior Shade T SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 _ 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen _ 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen _ 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen _ 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 Bug Screen 0.76 •28 29 Bug Screen 0.76 Run Initiation Time: 04108104 14:23:28 Run Code: 1081459408 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 11 of 37 Computer Method Summary (Part 2 of 3) C -2R The Bacigalupi Residence 4/8/2004 • Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Am. Tilt Comments .3.0. W.indow_Em-at (Noah) 27.3_ 0-3$0_ _0.27 0_ _90 WeatheLShiald_Glazing Zone 4 31 Window Front (North) 4.0 0.450 0.27 0 90 Weather Shield Glazing Zone 4 32 Window Left (East) 5.3 0.450 0.27 90 90 Weather Shield Glazing Zone 4 33 Window Left (East) 5.3 0.450 0.27 90 90 Weather Shield Glazing Zone 4 34 Window Left (East) 5.3 0.450 0.27 90 90 Weather Shield Glazing Zone 4 35 Window Rear (South) 4.0 0.450 0.27 180 90 Weather Shield Glazing Zone 4 36 Window Rear (South) 14.2 0.450 0.27 180 90 Weather Shield Glazing Zone 4 37 Window Rear (South) 17.1 0.380 0.27 180 90 Weather Shield Glazing Zone 4 Window Right (West) 21.3 0.450 0.27 270 90 Weather Shield Glazing Zone 4 39 Window Right (West) 13.5 0.450 0.27 270 90 Weather Shield Glazing Zone 4 40 Window Right West 21.3 0.450 0.27 270 90 Weather Shield Glazing Zone 4 INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin # _ Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:12 of 37 1 Computer Method Summary (Part 3 of 3) C -2R The Bacigalupi Residence 4/8/2004 • Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat F2 Insulation Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in Mortar _8.50 .015 94 _0_6Z n/a 0 Zone-JJ_I.nterior NLns Concrete. Heavyweight 850 3_50 28 0_98 n/a 0 Zone 1 / Slab on Grade Concrete, Heavyweight 424 3.50 28 0.98 n/a 2 ' Zone 1 / Slab on Grade Tile in Mortar 900 0.75 24 0.67 n/a 0 Zone 2B / Interior Mass L40cEete-aeav4weight X90 3.50 28 0.98 n/a 0 Zone 2B / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 125 07.0 0.0 Q Zone 1 Slab-Eedmeter- 35 070 2 0 Q Zwej Slab Perimeter 80 0_76 0.0 Q Zone 2B Slab Perimeter ----10 -O-Z6 20 Q Zoae26 Slab-Berimeter 160 076 X.0 _0 Zone 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC -1 (Master Suite) Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC 2A & 2B (Living Area) Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC 3A & 3B (Living Area) Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC -4 (Guest Suites) •Hydronic Piping Pipe Pipe Insul. System Name Length. Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 15.0 SEER Ducts in Attic 6.0 Setback HVAC -1 (Master Suite) Split Air Conditioner 15.0 SEER Ducts in Attic 6.0 Setback HVAC 2A & 2B (Living Area) Split Air Conditioner 16.0 SEER Ducts in Attic 6.0 Setback HVAC 3A & 3B (Living Area) Split Air Conditioner 16.0 SEER Ducts in Attic 6.0 Setback HVAC -4 (Guest Suites) WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Rheem HE -119-130 Large Gas Standard 1 130,000 130 0.94 0.0000 0.0 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. User Number: 3665 Computer Method Summary (Part 3 of 3) C -2R The Bacigalupi Residence 4/8/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight _74 X5.0 28 _0_98_ n/a _2. Zone2BLS1abnnG[ade Tile in Mortar 1,400 0_75 24 0_67 n/a 0 Zone 3 / Interior Mass Concrete, Heavyweight 1.400 3.50 28 _4,_9$_ n/a 0 Zone 3 / Slab on Grade Concrete, Heavyweight 209 3_50 28 0_98 n/a 2 Zone 3 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 8 0.76 0.0 0 Zone 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments •Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments } WATER HEATING SYSTEMS Ratedl Tank Energy Fact! Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name 'Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Comouter Method Summary (Addendum) C -2R The Bacigalupi Residence 4/8/2004 • Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC -1 (Master Suite)' must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1 (Master Suite)" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -1 (Master Suite)" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -1 (Master Suite)' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual HIGH MASS Design(see C -2R) - Verify Thermal Mass: 850 sqft Tile in Mortar Interior Mass, 0.75' thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 850 sqft Exposed Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 424 sqft Covered Slab Floor, 3.50" thick at Master Suite The HVAC System "HVAC 2A & 2B (Living Area) " must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC 2A & 2B (Living Area) " has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified The HVAC System "HVAC 2A & 2B (Living Area) " has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified The HVAC System "HVAC 2A & 2B (Living Area) " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 900 sqft Tile in Mortar Interior Mass, 0.75' thick at Downstairs (Living / Dining) HIGH MASS Design(see C -2R) - Verify Thermal Mass: 900 sqft Exposed Slab Floor, 3.50" thick at Downstairs (Living / Dining) HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form GF -6R. Plan Field . The HVAC System "HVAC -1 (Master Suite)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC 2A & 2B (Living Area) " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rate must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC 3A & 3B (Living Area) " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rate must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -4 (Guest Suites)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 04/08/0414:23:28 Run Code: 1081459408 EnergyPro 3.1 7 EnergySoft User Number: 3665 Job Number: Page: 15 of 37 Computer Method Summary (Addendum) C -2R The Bacigalupi Residence 4/8/2004 • Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. F Plan Field Ll L HIGH MASS Design(see C -2R) - Verify Thermal Mass: 74 sqft Covered Slab Floor, 3.50" thick at Downstairs (Living / Dining) The HVAC System "HVAC 3A & 3B (Living Area) " must meet all CEC Criteria for a Zonally Controlled system serving only Living Area. The HVAC System "HVAC 3A & 36 (Living Area) " has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified The HVAC System "HVAC 3A & 36 (Living Area) " has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified The HVAC System "HVAC 3A & 36 (Living Area) " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HIGH MASS Design(see C-213) - Verify Thermal Mass: 1400 sqft Tile in Mortar Interior Mass, 0.75' thick at army i c en n ry aun rryY HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1400 sqft Exposed Slab Floor, 3.50" thick at Family/Kitchen/Entry/Laundry HIGH MASS Design(see C -2R) - Verify Thermal Mass: 209 sqft Covered Slab Floor, 3.50" thick at Family/Kitchen/Entry/Laundry The HVAC System "HVAC -4 (Guest Suites)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas The HVAC System "HVAC -4 (Guest Suites)" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4 (Guest Suites)" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4 (Guest Suites)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form GF -61R. 71aField r I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:16 of 37 1 "ROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME The Baciaa[UDi Residence DATE 4/8/2004 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-22 5 ASSEMBLY NAME R-23 Wall W.23.2x6.16 0.31 7 0.37 s 2.60 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 24.11 TYPE (check one) X Wall W W Ceiling / Roof aFRAMING MATERIAL Wood p Z FRAMING % 15 % Framing 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) THICK- NESS (in.) 0.875 0.010 0.375 7.250 0.625 SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-22 5 Gypsum or Plaster Board 6 0.31 7 0.37 s 2.60 s 0.68 INSIDE SURFACE AIR FILM THICK- NESS (in.) 0.875 0.010 0.375 7.250 0.625 SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.465 0.465 22.000 7.178 0.562 0.562 0.31 3.47 0.37 1.29 2.60 0.26 0.68 0.6801 0.680 24.11 9.29 01=1 *HEAT CAPACITY (Optional) WALL WEIGHT (Ibs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 3.47 0.37 1.29 2.60 0.26 0.68 15.71 TOTAL HC 4.0 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0415 0.85 ] + r -,x 0.1076 X L 0.15 ] 1 / Rc 1 - (Fr-/. /100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:17 of 37 1 3ROPOSED CONSTRUCTION ASSEMBLY ENV -3 NAME The Baciaalmi Residence DATE 4/8/2004 COMPONENT DESCRIPTION DESCRIPTION RAMING OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-22 3 Gypsum or Plaster Board 4 0.37 5 ASSEMBLY NAME R-23 Wall .23.2x6.16 -2 0.68 7 ASSEMBLY U -VALUE 8 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 23.98 TYPE (check one) x Wall lL 0 W Ceiling / Roof NFRAMING MATERIAL Wood p Z FRAMING % 15 % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAI R -VALUE DESCRIPTION RAMING OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-22 3 Gypsum or Plaster Board 4 0.37 5 2.60 6 0.68 7 ASSEMBLY U -VALUE 8 9 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE THICK- NESS (in.) RAMING ❑ © ❑ El El El El 0.170 0.625 7.250 0.625 7.178 0.562 0.562 0.37 1.29 2.60 0.26 SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 22.000 7.178 0.562 0.562 0.37 1.29 2.60 0.26 0.68 Fr% / 100 ASSEMBLY U -VALUE 0.6801 0.680 23.98 9.15 KG KT *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0417 X 0.85 ] 2.60 0.26 0.68 3.47 0.37 1.29 2.60 0.26 0.68 Fr% / 100 ASSEMBLY U -VALUE 8 7 TOTAL HC 2 6 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0417 X 0.85 ] + [ 0.1093 X 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:18 of 37 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Baci alu i Residence 4/8/2004 SYSTEM NAME FLOOR AREA HVAC -1 (Master Suite) 1,274 Number of Systems 1 Heating System Output per System 90,000 Total Output (Btuh) 90,000 Output (Btuh/sgft) 70.6 Cooling System Output per System 60,000 Total Output (Btuh) 60,000 Total Output (Tons) 5.0 Total Output (Btuh/sgft) 47.1 Total Output (sgftrron) 254,8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.57 Airflow (cfm/Ton) 400.0 Outside Air (%) 4.8 Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 31,034 7,113 HSX19-060/G60UHV-60C-110X (5) 44,851 5,119 Total Adjusted System Output 44,851 5,119 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK i Aug 2 pm EATING SYSTEM PSYCHROMETRICS (Airstream Tei 24.0 OF 67.4 OF ■ 109.10F Outside Air 96 cfm Heating Coil 69.5 OF res at Time of Heatin 109.1 OF Supply Fan 2000 cfm Return Air Ducts E 26,272 90,000 90,000 Jan 12 am Supply Air Ducts 108.6 OF ROOMS 70.0 OF (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 14.1/80.3°F 74.5/61.6°F. 53.8/52.6°F 53.8/52.6°F � J � Outside Air 96 cfm Cooling Coil 72.6/60.5 °F O Supply Air Ducts Supply Fan 54.3/52 . 8 OF 2000 cfm 50.8% R.H. ROOMS 72.0 / 60.3 OF Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 19 of 37 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Baci alu i Residence 4/8/2004 SYSTEM NAME FLOOR AREA ., HVAC 2A & 2B (Livinq Area) 1.284 EA 24.0 of 311 0 Outside Air 96 cfm 69.5 of 67.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 40,176 7,4701 HSX19-060/G60UHV-60C-110X (5) 44,667 5,516 90,000 Total Adjusted System Output 44,667 5,516 90,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 109.0 of Heating Coil 109.0 of O Supply Air Ducts Supply Fan 108.4 of 2000 cfm ROOMS 70.0 of Return Air Ducts I (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 14.1 / 80.3 of Outside Air 96 cfm 72.8/60.8 of 74.7/61.90F = 54.1/52.90F Cooling Coil 0 Supply Fa 2000 cfm 54.1 / 52.9 of Supply Air Ducts Fan h Return Air Ducts '11 54.8/53 . 2 of 51.6% R.H. ROOMS 72.0 / 60.5 OF 1 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Paae:20 of 37 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Baci alu i Residence 4/8/2004 • SYSTEM NAME FLOOR AREA HVAC 3A & 3B(Living Area 1,609 EA 24.0 of 67.1 OF Outside Air 121 cfm 69.4 of LING SYSTEM PSYCH 14.1 / 80.3 of Outside Air 121 cfm 72.8/61.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 2,472 43,353 6,245 754 31,104 0 2,168 1,555 0 0 12 5,377 3,263 121 5,916 0 0 2,168 1,555 53,065 9,5091 HSX19-036/G60UHV-36A-070X (3) 51,797 8,305 Total Adjusted System Output 51,797 8,305 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 108.8 of Heating Coil Supply Fan 2400 cfm 40130 108,000 108,000 Jan 12 am 108.8 of -� Supply Air Ducts 108.2 of ROOMS 70.0 of in Return Air Ducts 4 74.9 / 62.5 OF . 54.9 / 53.8 of Cooling Coil Supply Fa 2400 cfm 54.9 / 53.8 of Supply Air Ducts Fan 55.8/54.1oF 53.7% R.H. ROOMS 72.0 / 61.1 of EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page 21 of 37 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY NAME The Baciaalupi Residence . SYSTEM NAME HVAC -4 (Guest Suites) Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 4/8/2004 FLOOR AREA 929 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 2617 4,797 HSX19-036/G60UHV-36A-070X (3) 25,955 4,205 Total Adjusted System Output25,955 4,205 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm TING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Tim 24.0 of 66.9 of ■ 108.6 of Outside Air 70 cfm 69.5 of 14.1 / 80.3 of Outside Air 70 cfm 72.8/61.4 of Heating Coil 0 Supply Fan 1200 cfm 16,508 54,000 54,000 Jan 12 am 108.6 of Supply Air Ducts 108.1 of ROOMS 70.0 of k Return Air Ducts 4 at Time of Cool 75.2 / 62.7 of . 55.2 / 54.0 of Cooling Coil 0 Supply Fa 1200 cfm 55.2 / 54.0 of Supply Air Ducts Fan h Return Air Ducts `S 56.0/54 . 3 of 54.0% R.H. ROOMS 72.0 / 61.1 of EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 22 of 37 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:23 of 37 PROJECT NAME The Baci alu i Residence DATE 4/8/2004 . SYSTEM NAME HVAC -1 Master Suite FLOOR AREA 1,274 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Master Suite 1 1,275 24,317 4,306 1,275 24,317 4,306 471 19,612 • PAGE TOTAL 1 1,275 24,317 4,306 471 19,612 TOTAL 1,275 24,317 4,306 471 19,612 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:23 of 37 ROOM LOAD SUMMARY PROJECT NAME The Baci alu i Residence DATE 4/8/2004 SYSTEM NAME HVAC 2A & 2B(Living Area FLOOR AREA 1,284 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2A Upstairs (Vic's Retreat) 1 . 462 8,570 1,048 462 8,570 1,048 115 4,778 Zone 2B Downstairs (Living / Dining) 1 1,296 24,047 3,657 1,296 24,047 3,657 437 18,144 PAGE TOTAL 1 1,758 32,617 4,705 552 22,922 TOTAL 1 1,758 32,617 4,705 552 22,922 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 24 of 37 41 ROOM LOAD SUMMARY , :1 PROJECT NAME The Baci alu i Residence DATE 4/8/2004 SYSTEM NAME HVAC 3A & 3B(Living Area FLOOR AREA 1,609 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 3 Family/Kitchen/Entry/Laundry 1 2,472 43,353 6,245 2,472 43,353 6,245 754 31,104 PAGE TOTAL 1 2,472 43,353 6,245 754 31,104 TOTAL 1 2,472 43,353 6,245 754 31,104 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 25 of 37 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:26 of 37 PROJECT NAME The Baci alu i Residence DATE 4/8/2004 . SYSTEM NAME HVAC -4 Guest Suites FLOOR AREA 929 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 4 Guest Suites (Upstairs) 1 1,212 20,969 2,929 1,212 20,969 2,929 289 11,894 s IF I PAGE TOTAL 1 1,2121 20,969 2,929 289 11,894 TOTAL 1 1,212 20,969 2,929 289 11,894 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:26 of 37 7 ROOM HEATING PEAK LOADS Project Title Date ` • The Bacigalupi Residence 4/8/2004 Room Information Desi n Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area 1,274 Outdoor Dry Bulb Temperature . 24 OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 603 Infiltration: r 1.00 X 1.080 X 1 274 X 9.50 X 6] X 46 = 5 009 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,612 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 27 of 37 964.0 x 0.0280 X 46.0 = 1,242 981.4 X 0.0514 X 46.0 = 2,320 101.1 x 0.4500 X 46.0 = 2,093 217.0 X 0.0518 X 46.0 = 517 17.5 X 0.3872 X 46.0 — 312 48.0 x 0.3800 x 46.0 = 839 perimeter =160.0 x x. 45.5 = 7,280 X x c X X = X X = X x _ X X X X = x X X X X X = X X X X X X X X = X X X X X X x x _ X X X X X X = X X = X X X x = X X X •X X X X X X X X X = X X = X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 603 Infiltration: r 1.00 X 1.080 X 1 274 X 9.50 X 6] X 46 = 5 009 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,612 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 27 of 37 ROOM HEATING PEAK LOADS Project Title Date •The Bacigalupi Residence 4/8/2004 Room Information Design Conditions Room Name Upstairs (Vic's Retreat) Time of Peak Jan 12 am Floor Area 310 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr Ll 310.2 310.2 632.4 46.6 40.0 0.0299 0.0280 0.0514 0.4500 0.3800 Items shown with an asterisk (') denote conduction through an interior surface to another room. Infiltration: L 1.001X 1.080 x 310 x 9.50 x 0.50 / 60] x Schedule Air Sensible Area Ceiling Height ACH Fraction AL HOURLY HEAT LOSS FOR ROOM 0.0 46.0 46.0 46.0 46.0 Page Total: 46 W 0 400 1,495. 965 699 3 559 _• 1219 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 28 of 37 4,778 ROOM HEATING PEAK -LOADS - Project Title f - Date The Rggb lupi Residence 4/8/2004 Room Information Desi n Conditions Room Name Downstairs (Living Dining) Time .of Peak Jan 12 am Floor Area i 974 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 7001= Conduction Area U -Value AT of Btu/hr • Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 13 712 Infiltration: 1.00 x 1.080 x 974 x 11.00 x 60] x chedule Air Sensible Area Ceiling Height ACH OT Fraction ' TOTAL HOURLY HEAT LOSS FOR ROOM f 18,144 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 29 of 37 s" • 973.7 x x x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x X x x x x x x x x x x x x x x x x x x x x x x x x. x, x x x x x x x x x x x 46.0 = = = = . = = = _ = = = = = = = = = = = = = = = = = _ _ = = = = = = = = = = = 1,254 677.0 0.0514 46.0 1601 240.0 0.3800 46.0 4195 124.0 0.4500 46.0 2,567 perimeter = 90.0 45.5 4,095 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 13 712 Infiltration: 1.00 x 1.080 x 974 x 11.00 x 60] x chedule Air Sensible Area Ceiling Height ACH OT Fraction ' TOTAL HOURLY HEAT LOSS FOR ROOM f 18,144 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 29 of 37 s" • 0 ROOM HEATING PEAK LOADS Project Title Date The Bad alupi Residence 4/8/2004 Room Information Desicin Conditions Room Name Family/Kitchen/Entry/Laundry Time of Peak Jan 12 am Floor Area 1,609 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr. 1228.0 X X x X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 X X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x I x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _ 1,582 1,093.9 0.0514 46.0 2,586 41.0 0.4500 46.0 849 417.0 0.0518 46.0 994 48.0 0.3872 46.0 855 459.1 0.3800 46.0 8,025 perimeter =188.0 45.5 8,554 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 23 445 Infiltration: 1 1.001 x 1.080 x 1 609 x Height x 60] x 46 = 7 659 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 31,104 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 30 of 37 ROOM HEATING PEAK LOADS Project Title Date Am The Baci alu i Residence 4/8/2004 Room Information Design Conditions Room Name Guest Suites (Upstairs) Time of Peak Jan 12 am Floor Area 929 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr 0 14.1 350.0 528.7 50.0 928.7 1,170.3 61.5 94.2 207.5 17. 0.0291 0.0299 0.0291 0.0280 0.0514 0.3800 0.4500 0.0518 0,3872 Items shown with an asterisk (') denote conduction through an interior surface to another room. Infiltration:[ 1.00 x 1.080 x 929 x 8.60 x 0.50 / 6] x Schedule Air Sensible Area Ceiling Height ACH Fraction x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0 = = = = = = = = = = = = = = = = = = = = 0 46.0 727 46.0 67 46.0 1,196 46.0 2.767 46.0 1,075 46.0 1,950 46.0 495 46.0 312 Page Total: 46 AT s 5S9 3 305 •1 TOTAL HOURLY HEAT LOSS FOR ROOM 11,894 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 31 of 37 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY The Bacigalupi Residence 4/8/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof R.38.2x14.16 R-23 Wall .23.2x6.16 Weather Shield Glazin R-23 WallW.23.2x6.16 (W-2) Solid Wood Door Weather Shield Glazing Area U -Value 217 1 0.05181 Master Suite 72°F 115°F 43°F X X X X X X DETD' = = = = = = Btu/hr 62.0 1,674 41.6 2,098 43.0 1,956 41.6 468 41.6 282 43.0 784 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 7,263 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGlsWdw (A) ((North) CsmntWdw-(.61 (East) FxdGlsWdw 132 (East) FrnchDr 29 (South) CsmntWdw (E) (West) CsmntWdw F (West) Awning G (West) CsmntWdw H (West) CsmntWdw I (West) ( 0.0 x X X x X x x x x x 1 + + + + + + + + + + 39.0 X x x x X x X x X x 15) X X x X x )x 0.378 = = = = = = = = _ = 221 ( 0.0 1 4.0 73)x 0.30 88 ( 0.0 1 6.3 73) 0.378 174 ( 0.0 1 48.0 32)x 0.30 462 ( 0.0 1 15.0 73) 0.30 329 ( 0.0 1 22.5 73)X 0.30 494 ( 0.0 1 4.0 73) 0.30 88 ( 0.0 1 4.0 73)x 0.30 88 ( 0.0 1 6.3 73) 0.30 138 ( I • S h d Page Total 2 os2 c e . Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,274 X 0.500 Watts/sqft x 3-419 Btuh/Watt - 2,174 Occupants 1.00 x 1,274 x 250 Btuh/oCC. / 200 sgft/oCC. = 1,593 Receptacle 1.00 x 1,274 x 1.500 Watts/sqft x 3.413 Btuh[Watt = 6,523 Process �1.000xx 1,274 x X0.0000 Watts/sqft X 3.41 Btuh/Watt = 0 Infiltration: 00 x I 1.o89j x 27� x E o� x 0_50 / 60] 43 = 4 X83 Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,317 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 274 x 200 Btuh/occ. / 200 sqft/occ. = 1 274 Receptacle 1.00 x 1 274 x 0.000 Watts/sgft X 3.41 BtuhlWaft = 0 Process 1.00 x 1 274 x 0.000 Wafts/sgft x 3.41 BtuhlWaft = 0 Infiltration: 1.00 x 4 840 x 1 274 x 9.50 x0.50 / 60] 0.00621 = 3 032 -Schedule Air Latent Area Ceiling Height ACH Ow Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,306 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 32 of 37 C� • • RESIDENTIAL ROOM COOLING LOAD SUMMARY The Bacigalupi Residence 4/8/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction 1. Design Equivalent Temperature Difference (DETD) Area U -Value Items shown with an asterisk (') denote conduction through Solar Gain an interior surface Orientation to another room. Shaded Area ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( ( ( ( ( ( X x x x x x x x X X SGF CsmntWdw J2 (North) 1 Fm.chnr (43) CsmntWdw K (East) (South) 1 1 CsmntWdw J1 (West) 1 878 4.0 32)X 0.30 38 21.3 73)x 0.30 467 Upstairs (Vic's Retreat) 72°F 115°F 430F DETD1 x 0.0 x 62.0 x 41.6 x 43.0 x 43.0 x X X X Page Total Btu/hr 0 539 1,352 - 902 654 3 446 + + + + + + + + + + Unshaded Area x x X x x x x X X X SGF x x )x )x )x )X )X )X SC = = = = = = = = = = Btu/hr 21.3 15) 0.30 96 40.0 73) 0.30 878 4.0 32)X 0.30 38 21.3 73)x 0.30 467 Sched. Page Total 1 aso Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 310 x 0.500 Watts/sgft x 3.41 Btuh/Watt = 529 Occupants 1.00 X 310 X 250 Btuh/occ. / 200 sgft/occ. = 388 Receptacle 1.00 x 310 x 1.500 Watts/sgft x 3.413 Btuh/Waft = 1,588 Process 1.00 x ��3100x�x 0.000 Watts/sqft x 3.41 Btuh/Watt = 00 Infiltration: [ 00 x 0$0 x E 3t x 9_50 x 0_50 /6o] E�_A Schedule Air Sensible Area Ceiling Height ACH 4T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,570 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 310 x 200 Btuh/occ. / 200 sqft/occ. = 310 Receptacle 1.00 x 310 x 0.000 Watts/sqft x 3.41 Btuh[Watt = 0 Process 1.00 x 310 x 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Infiltration:[ 1.00 x 4 840 x 31 x 9.50 x 0.50 / 60] 0.00621 = 738 Schedule Air Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,048 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 33 of 37 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Bacigalupi Residence 4/8/2004 • Project Title Date Room Name Downstairs (Living / Dining) Design Indoor Dry Bulb Temperature: 720F Design Outdoor Dry Bulb Temperature: 1 150F Design Temperature Difference: 430F • Conduction IR -23 Wall (W.23.2x6.16) I Area U -Value 677 0.05 X X X X X X X X X DETD' = = = = = = = = = Btu/hr 62.0 1,691 41.6 1,448 43.0 3,922 43.0 2,399 CsmntWdw O (South) 15) 0.30 271 ( 0.0 1 60.0 15 0.30 1. Design Equivalent Temperature Difference (DETD) Page Total 9 459 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FrnchDr 01 (North) chDL(02) (North) FrnchDr 03 (North) FrnchDr 26 (South) CsmntWdw (27) (South) CsmntWdw 28 (South) CsmntWdw O (South) 15) 0.30 ( 0.0 x X X X X x x x x 1 + + + + + + + + + 60.0 x X X x x x x x x 15 ) X x )X x x )x )x-- 0.30 = = = = = = = = 271 ( 0.0 1 60.0 15) 0.30 271 ( 0.0 1 60.0 15 0.30 271 ( 0.0 1 60.0 32) 0.30 577 ( 0.0 1 60.0 32) 0.30 577 ( 0.0 1 60.0 32)X 0.30 577 ( 0.0 1 4.0 32)X 0.30 38 ( ( Sched. Page Total 2 581 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 974 x 0.500 Watts/sgft x 3.413 BtuhlWatt = 1,662 Occupants 1.00 X 974 X 250 Btuh/occ. / 200 sgft/occ. = 1,217 Receptacle 1.00 x 974 x 1.500 Watts/sqft x 3.413 Btuh/Watt = 4,985 Process 1.00 x 974 x 0.000 Watts/sq�ft x 3.413 Btuh/VVatt = 0 Infiltration: x 80 x �9 X41 x 11 oo x E pD / 60] [_ 3J = i4 chedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,04J Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 974 x 200 Btuh/occ. / 200 sqft/occ. = 974 Receptacle 1.00 x 974 x 0.000 Watts/sgft X 3.41 BtuhMatt = 0 Process 1.00 x 974 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Infiltration: 11.00 x 4,8401 x 974 x 11.00 x 0.50 / 60] ed0.00621 = 2 683 chule Air Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,657 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 34 of 37 �J • • RESIDENTIAL ROOM COOLING LOAD SUMMARY The Bacigalupi Residence 4/8/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof R.38.2x14.16 R-23 Wall .23.2x6.16 Weather Shield Glazing R-23 Wall .23.2x6.16 (W-2) Solid Wood Door Weather Shield Glazing 1. Design Equivalent Temperature Difference (DETD) Area 1 228. X 1,093. X 41. X 417. X 48.0 X 459.1 X X x X Family/Kitchen/Entry/Laundry 72°F 115°F 430E U -Value 1 0.05181 X X X X X X DETD' = = = = = = Btu/hr 62.0 2,132 41.6 2,339 43.0 793 41.6 899 41.6 773 43.0 7.502 X X X Page Total 1 14,439 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw C North SwngG.IsDr_(in) (East) CsmntWdw D (East) Swn GlsDr 22 (East) SldgGIsDr (23) (South) Sld GlsDr 24 (West) FrnchDr 04 West FrnchDr 05 West 450 ( 0.0 1 20.0 ( 0.0 X1 X x x x x x x X X + + + + + + + + + + 21.0 X X X x X x X x x x 15) X )x x x )x )x 0.30 = = = = = = = = = = 95 ( 0.0 1 20.5 73 0.30 450 ( 0.0 1 20.0 73)x 0.30 439 ( 0.0 1 42.6 73) 0.30 935 ( 0.0 1 150.0 32) 0.30 1,443 ( 0.0 1 150.0 73)X 0.30 3,291 ( 0.0 1 48.0 73)X 0.30 1,053 ( 0.0 1 48.0 73)X 0.30 1,053 ( ( Sched. Page Total 1 8.75 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,609 x 0.500 Wafts/sqft x 3.41 Btuh/Watt = 2,746 Occupants 1.00 X 1,609 X 250 Btuh/occ. / 200 sqft/occ. - 2,012 Receptacle 1.00 x 1,609 x 1.500 Watts/sqft x 3.413 Btuh/Watt - 8,239 Process �1.000x50 =0 x 1,609 x 0.000 Watts/sgfttx 3.41 Btuh/Watt = 0 Infiltration: �� x 1.080 x 6Q9 x x . / 60] 43 = 159 Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 43,353 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 609 x 200 Btuh/occ. / 200 sgft/occ. = 1 609 Receptacle 1.00 X 1 609 X 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Process r 1.00 x 1 609 x 0.000 Watts/sqft x 3.413 Btuh/Waft = 0 Infiltration: I 1.00 x 4 840 Air Latent Area Ceiling Heighx 1 60 x Height x ACH 60] 0.00621 = 4 636 chedule pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,245 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 35 of 37 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Bacigalupi Residence 4/8/2004 • Project Title Date Room Name Guest Suites (Upstairs) E 0 Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Raised Conditioned Floor Stone Raised Floor Stone Raised Floor Stone W-2 R-38 Roof R.38.2x14.16 R-23 Wall W.23.2x6.16 Weather Shield Glazin Weather Shield Glazin R-23 Wall .23.2x6.16 M-2) .olid_Wood_Doo. Area U -Value 0.0291 0.0299 0.0291 0.0280 0.0514 0.3800 0.4500 0.0518 0.38 720F 115°F 430F X X X X X X X X X DETD 1 = = = = = = = = = Btu/hr 0.0 0 33.0 522 33.0 48 62.0 1,612 41.6 2,502 43.0 1,005 43.0 1823 41.6 448 15)x 8 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 8 242 Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FrnchDr 53 (North) EmchDr (45) (North) CsmntWdw N _ North CsmntWdw M1 (East) CsmntWdw (M2) (East) CsmntWdw M3 (East) CsmntWdw P South CsmntWdw Q1 (South) FrnchDr 49 (South) CsmntWdw Q2 West ( 0.0 X1 x x X x x x X1 + + + + + + + + + + 17.1 X X x x x x X x 15) X X x X x x x 0.30 = = = = = = = = = = 77 ( 0.0 1 27.3 15) 0.30 123 ( 0.0x 1 4.0x 15)x 0.30 18 ( 0.0 1 5.3 73) 0.30 116 ( 0.0x 1 5.3X 73)x 0.30 116 ( 0.0 1 5.3 73) 0.30 116 ( 0.0 1 4.0 32)x 0.30 38 ( 0.0 1 14.2 32) 0.30 137 ( 0.0 1 . 17.1 32) 0.30 164 (1 0.0 1 21.3 73) 0.30 4671 Sched. Page Total 1 37a Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 929 x 0.500 Watts/sgft x 3.41 Btuh[Watt - 1,585 Occupants 1.00 X 929 X 250 Btuh/occ. / 200 sgft/occ. - 1,161 Receptacle 1.00 x 929 x 1.500 Watts/sgft X 3.413 Btuh/Watt = 4,755 Process �1.000xx 929 x 0.000 Watts/sgft x 3.413Btuhh Watt = 00 Infiltration: 1.Q0 x l 1_01301 x 92s x 8 6 0 �o o x / 60] �43J = [= ,oao Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,9691 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 929 x 200 Btuh/occ. I 200 sqft/occ. = 929 Receptacle 1.00 X 929 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process f 1.00 x 929 x 0.000 Watts/sqft x 3.41 Btuh[Watt = o Infiltration: 1.00 x 4840 x 92 x 8.60 x 0.50 / 60] 0.00621 = 2 001 chedule Air Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,929 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 36 of 37 • is • RESIDENTIAL ROOM COOLING LOAD SUMMARY The Bacigalupi Residence 4/8/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Guest Suites (Upstairs) 72°F 115°F 43°F Conduction Area U -Value DETD' Btu/hr X X X X X X X x X 1. Design Equivalent Temperature Difference (DETD) Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr CsmntWdw R (West) ( 0.0 x 1 + 13.5 X 73)X 0.30 = 296 CsmntW_d (West) ( 0.0 x 1 + 21.3 x 73)x QJ01 = 467 ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = (I X I + X I )X Sched. Page Total 764 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 929 X 0.500 Watts/sqft xA3.*.413 Btuh/Watt = 1,585 Occupants 1.00 X 929 X 250 Btuh/occ. / sgft/occ. = 1,161 Receptacle 1.00 x 929 x 1.500 Watts/sgft x BtuhlWaft = 4,755 Process 1.00 x 929 x 0.000 Watts/sgft x��Btuh/Watt = 0 Infiltration: [ 1.00 x Q80 x x 8 60 x 0_50 / 60] �4.3J = 3 0;30 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20969 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 929 x 200 Btuhlocc. / 200 sgft/occ. = 929 Receptacle 1.00 x 929 x 0.000 Watts/sqft X 3.41 Btuh/VVatt = 0 Process r 1.00 x 929 x 0.000 Watts/sgft x 3.413 Btuh/VVatt = 0 Infiltration: I 1.00 x 4 840 x 92 x 8.60 x 60] 0.00621 = 2 001 "'--- chedule Air Latent Area Ceiling Height ACH Dyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,929 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 37 of 37