06-1351 (AR)4 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: 06-00001351 78736 VIA CARMEL 646 -430 -007 - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIA 15075 Architect or ----------------- LICENSED CONTRACTOR'S DECLARATION t 4 BUILDING & SAFETY DEPARTMENT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000).of Division 3 of the Business and Professionals Code, andmyLicense is in full force and effect. License Class: 13 License No.: 762987 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or.county that requires a permit to construct, alter, improve; demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).. 1—) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending, agency for the performance of the work for which this permit is issued ISec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERAIIT PERMIT Owner: DICKENSON LARRY S 7509 SE 76 MERCER ISLAND, WA 98040 Contractor: TD DESERT'DEVELOPMENT LP P O BOX 1716 LA QUINTA, CA 92247 (760)7.71-1941 Lic. No.: 762987 VOICE (760) 777-7012 FAX (760).777-7011 INSPECTIONS (760) 777-7153 Date: 5/30/06 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following.declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section.3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation .insurance carrier and policy number are: Carrier COMPWEST Policy Number CA005001482-001 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE.TO SECURE WORKERS'. COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180_days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date: . Signature (Applicant or Agent): Application Number . . . . . 06-00001351 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 171.00 Plan Check Fee 111.15 Issue Date Valuation 15075 Expiration Date 11/26/06 Qty Unit Charge Per Extension BASE FEE 45.00 14.00 9.0000 THOU BLDG 2,001-25,000 126.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 29.77 Plan Check Fee 7.44 Issue Date Valuation . . . . Expiration Date 11/26/06 .0 Qty Unit Charge Per Extension BASE FEE 15.00 182.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 6.37 420.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.40 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 30.50 Plan Check Fee 7.63 Issue Date Valuation 0 Expiration Date 11/26/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 1.00 6.5000 -------------------------------------------------------- EA MECH VENT FAN --------------------- 6.50 Permit . . . PLUMBING Additional desc . Permit Fee 36.00 Plan Check Fee 9.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/26/06 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 6.0000 EA PLB FIXTURE 18.00 1.00 3.0000 ---------------------------------------------------------------------------- EA PLB WATER INST/ALT/REP 3.00 Special Notes and Comments convert existing garage to 182 living LQPERAIIT Application Number . . . . . 06-00001351 -------------------------------------7-------------------------------------- Special Notes and Comments space and add 420 sq. ft. of garage.May 30, 2006 11:19:10 AM jjohnson -----------7-------------------------------------=-------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 11.12 STRONG MOTION (SMI) - RES 1.50 Fee summary ----------------- Charged ------------ Paid Credited Due Permit Fee Total 267.27 ---------- ---------- .00 ---------- .00 267.27 Plan Check Total 135.22 .00 .00 135.22 Other Fee Total 12.62 .00 .00 12.62 Grand Total 415.11 .00 .00 415.11 LQPERMIT Bin e , . if 5 - Pernik # T Project Address:? 0 ? ?j(— A. P. Number: 'City of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet u[�(� Owner's Name: 4-1 G� Address: '7W 7_5 c Legal Description: 7-72– City, ST, Zip &0 Z i 3 Contractor: Telephone: µ Address: 7/ Project Description: City, ST, Zip: , � ;F Z 2�3 z c 6e;zA Telephone: ? ?i l9 ec� xz State Lic. # : City Lie. #: 523 Arch., Engr., Designer:. ,i( 7 Address: 7 2 f3 8.p City, ST, Zip: Telephone:. Construction Type: Occupancy: State Lic. #: 3 '8 f Name of Contact Person: 4 e Project type (circle one): New i� Alter Repair Demo Sq.. F' L: # Stories: / # Units: Telephone # of Contact Person: ? ? l `� �. Estimated Value of Project: -Ir/ D'o 7.0 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd - Rec'd UCMG . PERMIT FEES Plan Sets2 2,�1sv t Plan Check submitted Item Amount Structural Calcs. Reviewed, read or corrections -Plan Check Deposit Truss Calcs. 2� Called.Conta Person Plan Check Balance Energy Calcs. Z Plans picked up f Construction Flood plain plan Plans resubmitted Mechanical Grading. plan' 2"'Review ready for correctio issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. II.O.A. Approval Plans resubmitted1 4 Grading IN ROUSE:- 7rd Review, ready for correcti nsrssue%A. ve mpact T Planning Approval Called Contact Person i.F.PPub.\Vks. Appr Date of permit issue V) School Fees < ^ale G -IF 5%3 . 09 AMPdAI3lL " : S//7 JlZRpora'2i 1 Total Permit Fees I" . r (� t op(( 5��d n(9 Date 6/9/06 No. 28568 Owner Larry Dickerson Address 78-736 Via Carmel City La Quinta Zip 92253 Tract # Type Residential Addition Lot # No. Street Unit 1 78736 Via Carmel Unit 2 Unit 3 Unit 4 Unit 5 Comments Garage Conversion CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 S.F. 182 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 BERMUDA DUNES r RANCHO MIRAGE b INDIAN WELLS d. PALM DESERT LA QUINTA INDIO yo. O y� APN # 646-430-007 Jurisdiction La Quinta Permit # Study Area No. of Units 1 Lot # No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 182 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Judy Halpain Check No. Name on the check Telephone 771.1941 Funding Exempt By Dr. Doris Wilson Superintendent Fee collected /exempted b h ron McGilvrey Payment Recd - - y`, $o.00 r <:"aver/Urider`• Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting �J TITLE 24 REPORT ` Title.24 .Report for: Dickenson.. -,Residence X78-736 Via Carmel CITY OF, LA QUINTA La Quinta, CADEPT. BUILDING &SAFETY APPFI®VED FOR CONS DA Project Designer: Curtis R. Shupe, Architect 72-880 Fred Waring Drive Suite A-5 Palm Desert, CA 92260 Report Prepared ,By: - r ,Joan D. Hacker Insu-form, Inc. 41-92.1 Beacon HIII•, Suite A Palm Desert, CA 922,11 (760)'779L 0657 , J,ob Number:, L -APR .3 2006 Date: 3/24/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number: User Number: 2655 t, TITLE 24 REPORT ` Title.24 .Report for: Dickenson.. -,Residence X78-736 Via Carmel CITY OF, LA QUINTA La Quinta, CADEPT. BUILDING &SAFETY APPFI®VED FOR CONS DA Project Designer: Curtis R. Shupe, Architect 72-880 Fred Waring Drive Suite A-5 Palm Desert, CA 92260 Report Prepared ,By: - r ,Joan D. Hacker Insu-form, Inc. 41-92.1 Beacon HIII•, Suite A Palm Desert, CA 922,11 (760)'779L 0657 , J,ob Number:, L -APR .3 2006 Date: 3/24/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number: User Number: 2655 TABLE OF CONTENTS Cover Page • 1 Table of Contents 2 Form CF -1 R Certificate of Compliance - 3 Form MF -1 R Mandatory Measures Summary 7 HVAC System Heating and Cooling Loads Summary .9 Room Load Summary 10 w t . , t EnergyPro 4.0 by EnergySoft Job Number. User Number. 2655 Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R -DickensonBesidence Total Conditioned Floor Area Existing + Add/Alt Existing Floor Area: 3R412QQ6 Project Title Natural Gas Slab on Grade Area: Ratio: 18.8% Date J_8=7_36_V_ia Carmel-La_Quinta Number of Stories: BUILDING ZONE INFORMATION 09-A3 Llvinn_Z°Ile Existing_ 0.9--A3 .LivingZone 01-A4 Llving-Zone Project Address # of Thermostat Zone Name Floor Area Building Permit # 1ns_u-form, Inc_ Living_Zone 2648 (760) 779-0657 1 nn CAnditioned--Setback- Documentation Author ❑ Telephone plan Check/Date -Ener fro Compli ce Method 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 6.45 6.30 0.15 ❑ Space Cooling 154.27 134.53 19.74 Fans 22.10 19.30 2.80 Domestic Hot Water 10.85 10.85 0.00 Pumps 0.00 0.00 0.00 Totals 193.67 170.98 22.68 Building Type: ndard: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: ❑ Addition Total Conditioned Floor Area Existing + Add/Alt Existing Floor Area: (East) 90 deg Raised Floor Area: Natural Gas Slab on Grade Area: Fenestration: ❑New ❑New El 09-A5 Addition Average Ceiling Height: Area: 496 ft2 Avg. U: 0.87 Number of Dwelling Units: Ratio: 18.8% Avg. SHGC: 0.69 Number of Stories: BUILDING ZONE INFORMATION 09-A3 Llvinn_Z°Ile Existing_ 0.9--A3 .LivingZone 01-A4 Llving-Zone ❑ # of Thermostat Zone Name Floor Area Volume Units Zone Type Type Living_Zone 2648 -26,480 1 nn CAnditioned--Setback- OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall- Wand- 150 _0 o74 -5=19_ R-0 0 1A0 _90 -Wall WQo-d- 400 074 -5_19 R-0 0_ 270 90 Wall- Wood 156 .074 R_19 R 0.0 0_ g0 .Door_ Clone- 24 n ISM _.None_ R -n n 0_9.0 Raol- Wood_ 417 _0-25_ _5_3.8_ R-0.0_ _315_ 0. Wall_ ZLaod_ _254 -0-J02 R-13 X0.0_ _9.0_ 90 Wall- Wood- 300_ _0.102 R-13 R_0 0 909.0 Wall- Wood- -5.05_ _0-102 R-13 R-0 0 l80 9.0 Wall- Woosi_ 554 _0102 R-13_ _8_0.0_ 2709.0 Wall_ Wood- 382 _0.102 R-13.1-0-_ 0_9.0 Root- Wood_ x,231 -0-049_ X19_ --R--0-0_ 9.0__0 2,648 ft2 2,231 ft2 0 ft2 2,648 ft2 10.0 ft 1.00 Vent Hgt. Area 2 �n/a Gains Condition Y / N Status JA IV Reference Location / Comments EX X ® ❑New ❑New El 09-A5 Addition 09-A5 Addition Kew-- 09-A5 Addition EX IN ❑New ❑New ❑Existing_ 28-A4 Addition 01-A18 Addition 09=A3 Living Zane ® X IN X El ❑Existing ❑Existing ❑ Removed- 09=A3 Lwmg.Zone _ A9=A3 Living -Zone 09-A3 Llvinn_Z°Ile Existing_ 0.9--A3 .LivingZone 01-A4 Llving-Zone ❑ ❑FAsting ❑ ❑ ❑ ❑ ❑ ❑ EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Paw:3 of 10 1 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R Dickenson Residence 3/24/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Tvoe Comments 1_ Madoly Bight_(flLotth)___20_0_ _Q= -NERC _0A0 _NERC 0_ _90_ Exis1ing_Milgazd_QtzVMtl_C1r1owE_ Addition 2 Window Front (East) 20.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Living Zone 3 Window Front (East) 12.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mill Uncoated Default Living Zone 4 Window Front (East) 24.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Living Zone 5 Window Front (East) 10.5 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Living Zone 6 Window Left (South) 9.0 0.870 NFRC 0_70 NFRC 180 90 Existing Double Mtl Uncoated Default Livin Zone 7 Window Left (,South) 12.00870 NFRC 0_70 NFRC 180 90 Existing_ Double Mtl Uncoated Default Living Zone 8 Window Left (South) 24.0 0.870 NFRC 0.70 NFRC 180 90 Existing_Double Mtl Uncoated Default Living Zone 5 Window Rear (West) 24.0 0.87 FRC 0.70 NFRC 270�9 Existing Double Mtl Uncoated Default Living Zone 1Q Window Rear (West) 40.0 0.870 NFRC 0_70 NFRC 270 90 Existing Double Mtl Uncoated Default Living Zone 1 Window Rear (West) 20.0 0.870 NFRC 0_70 NFRC 270 90 Existing Double Mtl Uncoated Default Living Zone 12 Window Rear (West) 75.0 0.870 NFRC 0_70 NFRC 270 90 Existing -Double Mtl Uncoated Default Living Zone 13 -WinRear fWest)_Z5.0_ O 70 NFRC 0.70 NFRC 270 _90 Removec0ouble MtLUacoated_DefauIt- -1-kingZone 2.0 14 Window Rear West) 11.0 0.870 NFRC 0_70 NFRC 270 90 Existing -Double Mill Uncoated Default Living Zone 15 Window Rear (West) 30.0 0.870 NFRC 0_70 NFRC 270 90 Existing Double Mtl Uncoated Default Living Zone 16 Window Right (North) 20.0 0.870 NFRC 0_70 NFRC 0 90 Existing Double Mtl Uncoated Default Living Zone 17 Window Right (North) 25.0 0.870 NFRC 0_70 NFRC 0 90 Existing Double Mill Uncoated Default Living Zone 18 Window Right (North) 9.0 0.870 NFRC 0_70 NFRC 0 90 Existing Double Mtl Uncoated Default Living Zone J2 Window Right (North) 15.0 0`870 _NFRC 0_70 NFRC 0 90 Existing Double Mtl Uncoated Default Living Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Condition Status Location/ Comments New Addition Existing Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 9.0 6.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 3.0 4.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 8.0 3.0 2.0 , 2. 2.0 5 Bug Screen 0.76 7.0 1.5 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 2.0 4.5 2.0 _0. 2.0 2.0 7 Bug Screen 0.76 3.5 4.5 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 9 Bug Screen -Bug 0.76 8.0 3.0 2.0 0.1 2.0 2.0 10 Screen 0.76 5.0 8.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 2.5 8.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 7.5 10.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 2.5 10.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 2.0 5.3 2.0 0.1 2.0 _ 2.0 15 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 2.5 4.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Type Length R -Val. Location JA IV Reference Slab Perimeter 18 None No Insulation 26-A1 Slab Perimeter 95 None No Insulation 26-A1 Run Initiation Time: 03/24/06 08:54:30 Run Code: 1143219270 EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:4 of 10 Condition Status Location/ Comments New Addition Existing Living Zone Run Initiation Time: 03/24/06 08:54:30 Run Code: 1143219270 EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:4 of 10 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R Dickenson Residence Project Title 3/24/2006 Date FENESTRATION SURFACES # Type Area True Cond. •Location/ U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 20. _MftdowJ3igbt (Notfb) 180_ 21 Window Right (North) 18.0 22 Window Right (North) 30.0 23 Window Right North) 30.0 0-M- 1FBC _0_Z0 _NERC 0 _9.0 Existing-Dauble-MtLUncoated_D.efault_ _Living Zone 0.870 NFRC 0_70 NFRC 0 90 Existing Double Mill Uncoated Default Livinq Zone 0.870 NFRC 0_70 NFRC 0 90 Existin _Double Mtl Uncoated Default Living Zone 0.870 NFRC0_70 NFRC 0 90 Existing Double Mtl Uncoated Default Livinq Zone 0.76 22 Bug Screen 0.76 23 Bug Screen 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 2.0 Window Overhang Hat.. Wd. Len. Hgt. LExt. REA 3.0 3.0 2.0 0.1 2.0 2.0 3.0 6.0 2.0 0.1 2.0 2.0 5.0 6.0 2.0 0.1 2.0 2.0 5.0 3.0 2. . 2. 2.0 Left Fin Dist. Len. Hgt. THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Length R -Val. Insulation Location JA IV Reference Condition Location/ Status Comments Right Fin Dist. Len. Hot. Run Initiation Time: 03/24/06 08:54:30 Run Code: 1143219270 EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:5 of 10 Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R Dickenson Residence 3/24/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Living Zone Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Existing Setback HVAC DISTRIBUTION Location Duct Duct Condition Ducts Coolino Location R -Value Status Tested? Living Zone Ducted Ducted Attic 2.1 Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Curtis R. Shupe, Architect 1 Title/Firm: 72-880 Fred Waring Drive Address: _ Suite A-5 Telephone Palm Desert, CA 92260 tic. #: '160 70 '73 C_ 133 b* exp 60 /.*. -3/2`/ L4& (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 41-921 Beacon Hill, Suite A Palm Desert CA 92211 Telephone: (760) 779-0657 (sig lure) 9 (date) Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ lil ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: rx� ❑ ❑ *§ 150(c): Minimum RA3 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). +§ 150(d): Minimum R-13 raised floor insulation in framed floors or. equivalent U -factor. ❑X ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ' r 1. Masonry and factory -built fireplaces have: i a. closable metal or glass door covering the entire opening of the firebox ❑ FRI ❑ b. outside air intake with damper and control, flue damper and control ❑ EK ❑ 2. No continuous burning gas pilot lights allowed. ❑ R ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ 0 ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. FRI ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑X El El' permeance rate no greater than 2.0 perm/inch. i § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ N ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ Q ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. t 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ER ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. , , ❑ IR ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with in ❑ ER ❑ having an installed thermal resistance of R-12 or greater. , 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. ❑ ❑X ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems >,15'psi, meet requirements of Table 123-A. Q ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ N ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed 0 ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. Q ❑ ❑ EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:7 of 10 Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and § 114: Pool and Spa Heating Systems and Equipment support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑X ❑ ❑ reductions in the cross-sectional area of the ducts. 2. System is installed with: 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. a. At least 36" of pipe between filter and heater for future solar heating. 4. Exhaust fan systems have back draft or automatic dampers: 1 ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are ❑ ® ❑ 7: Flexible ducts cannot have porous inner cores. r § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑X ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ® ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑X ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. X❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria 0 ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑X ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) ceriffed to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section ll19(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ Y ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. FX] ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more a] ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section I I9(d). EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:8 of 10 MVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Dickenson Residence DATE 3/24/2006 SYSTEM NAME FLOOR AREA 2,648 Living Zone Total Output (Tons) Number of Heating Sy Total Output (Btu Output (Btuh/sqfl ©u 140,000111 Output per System 5t$,000 Total Output (Btuh) Airflow (cfm) 116,000 Total Output (Tons) 1.67 9.7 Total Output (Btuh/sgft) Outside Air (%) 43.8 Total Output (sgftlTon) 0.00 273.9 Air System CFM per System 2,210 Airflow (cfm) 4,420 Airflow (cfm/sqft) 1.67 Airflow (cfm/Ton) 457.2 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 of 68.2 of 68.2 of Outside Air 0 0 cfm Supply Fan 4420 cfm 68.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11COIL TG.PEAK CFM I Sensiblel Latent CFM I Sensible 5,396 55,529 4,327 1,736 48,433 0 13,099 8,354 0 0 0 0 0 0 0 0 .13,099 81,727 4,327 0 8,354 65,140 Existing 71,679 40,202 140,000 Total Adjusted System Output71,679 40,202 140,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm I I Jan 12 am 98.0 of Heating Coil Time of k Return Air Ducts 'I Supply Air Ducts 96.2 of ROOMS 70.0 of OHUNG SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 111.0 / 77.6 of Outside Air 0 cfm 80.8/69.6 of 80.8/69.6OF 80.8/69.7OF M 65.5/64.6OF Supply Fan Cooling Coil 4420 cfm Return Air Ducts Supply Air Ducts 68.3 / 65.5 of 63.2% R.H. ROOMS 78.0 / 68.8 of EnergyPro 4.0 by EnergySoft User Number: 2655 Job Number: Page:9 of 10 ROOM LOAD SUMMARY PROJECT NAME Dickenson Residence DATE 3/24/2006 SYSTEM NAME Living Zone FLOOR AREA 2,648 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition ` Addition 1 656 6,753 1,229 656 6,753 1,229 220 6,143 Living Zone Existing Living 1 4,740 48,776 3,098 4,740 48,776 3,098 1,516 42,291 PAGE TOTAL 1 5,396 55,529 4,327 1 1,736 48,433 TOTAL 1 5,396 55,529 4,327 1,736 48,433 EnergyPro By EnergySoft User Number: User Job Number: Page:10 of 10