04-8307 (SFD)BUILDING & SAFETY DEPARTMENT
P.O. Box 1504 (760).777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA,QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153
BUILDING PERMIT
Application Number . . .
. . 0-4=00008307 Date
3/22/05
Property Address ,.
. 43350 PARKWAY ESPLANADE E
APN:
609-380-999-81 -293234-
Application description
DWELLING - SINGLE FAMILY DETACHED
Property Zoning
LOW DENSITY RESIDENTIAL
Application valuation...
126211
Owner
Contractor
LENNAR_ HOMES OF CALIFORNIA
LENNAR HOMES OF CALIFORNIA
INC
78401 HIGHWAY,111;. STE C
78401 HIGHWAY 111, SUITE
C
LA,QUINTA, CA
LA QUINTA
CA 92253
LA QUINTA CA 92253
WCC:, AON RISK SRVC
WC: MWC11114500
11/01/05.
WR 012005
CSLB: 728102
09/30/06
CCC: B
------------------cayop INT�tru
ture Information
Construct on T NCE DEPT
TYPE V - NON RATED
Occupancy Type
DWELLG/LODGING/CONG <=10
Flood Zone
NON -AO FLOOD ZONE'
Other struct info . . .
. CODE EDITION 2001
CRC,
# BEDROOMS
4.00
FIRE SPRINKLERS NO
GARAGE SQ FTG
447.00
r
PATIO SQ FTG
53.00
NUMBER OF UNITS
1.00
1ST FLOOR SQUARE FOOTAGE
2041.00
------------------------------------
Permit . . . . . . BUILDING•PERMIT
----------------------------------------
Additional desc
Permit Fee . . . . 734.00
Plan Check Fee
119.28
Issue Date
Valuation
126211
Qty Unit Charge Per
-
Extension
BASE FEE ''
639.50
27.00, 3.5000 THOU
BLDG 100,001-500,000
94.50
--------------------------------------------------=----
Permit .— ... . . ELEC-NEW
---------------------
RESIDENTIAL.-
Additional desc
" J
Permit.Fee . .
95.38 Plan Check.Fee
5.96
Issue,•Date
Val-uation . . . .
0
Qty Unit Charge Per
Extension
BASE FEE
15.00
2041.00 .0350
ELEC NEW RES - 1.OR 2 FAMILY
71.44
447.00 ..0200
ELEC GARAGE OR NON-RESIDENTIAL
8.94
• 's
P.O. Box 1504 •
78-495 CALLS TAMPICO '��� •
w VOFAX (760) 777-7011ICE (760) 777-7012
LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: Date: •O S
Applicant: Arc t ct or Engineer:
Applicant's Mailing Address: Ar hitect or Engineer's A cess:
ON(MA Tod
Lic. No.:
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
�I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
e, and ss Licen a is in full force and effect.
(/License Clas2s 2 /j%� License No. /
bD9t'e_ ✓ JContractok
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. ,If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
Xof the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
ss ed. My workers' compensation insurance cam a d olilcyy ggqujjj������b
arrier Policy Numbe �/]
I certify that, in the performance of the work for whicht- hhi pe it is issued, I shallott employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers', compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions.
oats /-0 Applicant(/
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes.
Signature (Applicant or Agent): ���'P
Page
2
Application Number
04-00008307 Date
3/22/05
--------------------------------------------------------
Permit . . . . . . GRADING PERMIT
-----------
Additional desc
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
'Valuation
0
Qty Unit Charge
Per
Extension
BASE FEE
15.00
-------------------------------------------------------------------------------
Permit . . . . . . MECHANICAL
Additional desc
Permit Fee . .
46.00 Plan Check Fee
2.88
Issue Date . . . .
Valuation . . . .
0
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 9:0000
EA MECH FURNACE <=100K
9.00
1.00 9.0000
EA MECH B/C <=3HP/100K BTU
9.00
1.00 6.5000
EA MECH VENT FAN
6.50
1.00 6,.5000
EA, MECH EXHAUST HOOD
6.50
---------------=---------------------------------------=--------------------
Permit . . . . PLUMBING
.Additional desc
Permit Fee . . . .
164.25 Plan -Check Fee
10.27
Issue Date . . . .
Valuation
0
Qty Unit Charge
Per
Extension
BASE FEE
15.00
16.00 6.0000
EA PLB FIXTURE
96.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
1.00 .7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
5.00 .7500
EA PLB GAS PIPE >=5
3.75
1.00 15.0000
------------------------------------------7---------7-----------------------
EA PLB GAS METER
15.00
Special Notes and Comments•
SFD - LOT 81. PLAN 1Y,
2041 SF. PERMIT
DOES NOT INCLUDE BLOCK WALL, POOL, SPA'
OR DRIVEWAY APPROACH.
75% PLAN CHECK FEE
REDUCTION APPLIED FOR
MULTIPLE ISSUANCE
OF SAME PLAN TYPE.
Other -Fees ... . . .
. . . . ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
1�C
4 f
Page 3
,II
i
Page 3
Appli-cation Number
04-00008307
Date
-3/22/05
Other Fees . .
. . .
ENERGY REVIEW FEE
11.93
DIF FIRE PROTECTION
-RES
97.00,
GRADING PLAN CHECK
FEE
.00
DIF LIBRARIES - RES
225.00
.DIF PARK MAINT FAC
- RES
5.00
DIF PARKS/REC - RES-_
502.00
STRONG MOTION (SMI)
- RES
12.62
DIF'STREET MAINT FAC
-RES
15.00
DIF TRANSPORTATION
- RES
1098.00
Fee summary
-----------------
Charged
Paid Creditec
Due
Permit Fee Total
----------
1054.63
--------------------
00
----------
CO
1054.63
Plan Check'Total.
138.39
.00
co,138.39
Other Fee Total
2429.55,
.00
CO
2429.55
Grand Total
3622.57
.00
CO
3622.57 .
.SEP -23-2005 FRI 07:12 AM TEAM HEATING & A/C FAX N0, 9516943803 P. 34
HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 1 oft CF -6R
Sita Addrpc-S C _d3_��ifi-P�rkura�r cnlanar�a Faat�l-a-flrlinfal r`!2 001KQ Dcr,,.*
Tract Number: 29323 Plan #= J y Phase: 12
Lot Number. 81 project: Esplanade Builder: Lennar Homes
An Installation certificate Is required to be posted at the building site or made avallble for all appropriate inspections.
Atter completion of final Inspection, a copy must be provided to the Building Deparhl'tent (upon request) and the building
owner at occupancy, per Section 10-1 03(b).
HVAC SYSTEMS:
Heating Equipment
equip, t:,c certmea Mtr NameIdenticle (SEER, etc.) I Location I Duct I Load- I Capacity 1
Tye and Model Number Systems (—CF -1R) l (attic, etc.) R -value (BTU I Hrl (BTU I Hrt
_ _..__._.a.,T,, .�,..� ..,-,, Y,.,r m Iwwr uuwv 1�. I) w elo w6wCIl oyuipinon[ Inazal�ea, z) equivalent to Or more
ffici
eent than that specified In the of tom lance (F CF -1 R) submitted for compliance with the Energy
Efficiency Standards for residend bui in ,and ) ui nt t meets r ex ad% the appropriate requirements for
manufactured devioes'(from plias Ce a cY eg No or art 6 vdh applicable.
(j Team Heating & Air, Inc
signature, Date insialung Subcontractor W. N.3me
OR General Contractor (Co. Name) OR Owner
MINIMUM REQUIREMENTS FOR 138 LEAKAGE COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage)
CFA:
SystemXl of
Indicate the ma mum a owe le putt Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
x 400 x (Cooling Capacity In Nominal Tons) x (0.06) fan flow
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow X.06
7iu Pressurization Test Results
! 100 x Test Leakage I Fan Flow � % Leakage
;Check Box for Pass or Fail (Pass 6% or lass) Pass al
"XT-24Compliance Credit was Taken for TXV TXV was installed x
!ys m of
;Indicate the max Mum I awa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 16 �.
1 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 .
400 x (Cooling Capacity In Nominal Tons) x (0.06) fan flow
21.7 x (Heating Capacitor In Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow X.06
u Pressurization Test Results
;100 x Test Leakage / Fan Flow = % LesRags
Check Box for Pass or Fail (Pass D 6% or Less) PPS31 Fail
[ T-24 Compliance Credit was Taken for TXV TXV was installed
PACE 1
F2001-01 (4-02) Action Now T-2-ICF6-RTD&TXV macro
SEP -23-2005 FRI 07;12 AM TEAM HEATING.& A/C FAX N0. 9516943803
P. 35
HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 2 of 2 CF -6R
Site Address: 43-350 Parkway Esplanade East, La Quinta, Ca92253 Permit Number
Tract Number. 29323.Plan # 1y Phase: 12
Lot Number. 81
Project: Esplanade .
System E:D of F-7
Indicate the maximum a owa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons)'x (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
M3 Pressurization Test Resu
100 x Test Leakage I Fan Flow o % Leakage
Check Box for Pass or Fall (Pass = 6% or Less)
T-24 Compliance Credit was Taken for TXV
ys em E:J of �I
Indicate the maximum a owa le Duct Leakage and the calculation used;
0.7 x Floor Area x (0.08) for Climate ,Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons) z (0,06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
D—Uff Pressurization Test Results
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
24 Compliance Credit was Taken for TXV
Pof
Indicate the max mum a owa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.08) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity In Nominal Tons) x (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
u Pressurization Test Results
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass T 6% or Less)
I— 'IT -24 Com (lance Credit was Taken for TXV
ys em of F''�
Indicate the mawmum allowable Dud Leakage and the calculation used;
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Coaling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity In Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
D—Uff Pressurization Test Resu
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
L_JT-24 Compliance Credit was Taken for TXV
X.06
X'06
X.06
X.06
TXV was
TXV was
TXV ww
TXV wai
Builder: Lennat Homes
I, the undersigned, verify that the above diagnostic test results and the work I performed associated with the tests) is
in conformance.with the requirements for I. uilder shall provide the HERS provider a copy of the _
CF -6R signed by the builder employees or u n ors Itifyl that diagnostic testing and -installation meet the
requirements for compliance credit.)
vb/h(+� Team Heating & Air, Inc.
eeld ign re, e 4subcontractor eine
Performed Installing
OR ceneral•Contractor (Co. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
PAGE 2
I F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro
I
r .
,SEP 27;2005 16:56 BCI*TESTINGrri1 0007000-00000
Ca10ERT Certified Rating September, 27 2005
Conditioned Fluor Arca: 1806 Square Feet
Conditioned Volume: O Cubic Feet
Front Orientation: N/A.
Number of Stories: I
Surface
Area
43350 Parkway Esplanade East
This Com Nance rating is for the home located.at:
P
La Quinta CA, 92253
Certificate Number:
CC3-1798350705
Orientation Area U U
SHGC SIIGC
Value
Date Inspected:
September, 27 2005
Ca10ERTS Rater:
William Henson
CC2004076
HERS Analyst:
N/A
R
Iiuildee/Developer:
Lennar.11omes
.Project:
Tapestry_@ Esplanade
T,
Plan Name:
Plan 1
$
S.
Lot Number:
081 -• Ph6" 12—
Specifics.about this home:
General information
Building velope
Conditioned Fluor Arca: 1806 Square Feet
Conditioned Volume: O Cubic Feet
Front Orientation: N/A.
Number of Stories: I
Surface
Area
Proposed
Actual
R U
Value I. -Factor
R
I Value
U
I Factor.
NY'AC Air JAwrihution
Duct Location: Attic -
Duct Leakage l'arget: 6.0
Duct insulation R -Value: 4.2 =TESTED
APPROVED A$ PART OF SAMPLE GROUP (pg t of 1)
Air 1r2fi1trut1( FIRM: BCI TESTING
glower Door Target: 120.0. --
ADDRESS: 77-760 COUNTRYCLU13 DRIVE, SUITE I
PALM DESSERT, CA. 92211
Rier Heating Pro osed
PHaNE: 76o•r72•2954 .
QTY]Size Size Nuel I EFJ Distribution
Water Hea[in ..S stem Aclua! CERTIFYING SIGNATURE DA
TY Size_ Fuel I Fes 1, Distribution
kiting Rusuhs
Associated to Group #10108
*Ibc energy ci ieiency retiug ofthis homu.ie dctcxminud using! t :alili,mip I Imme Knorgy Raling System (C -HERS) rulua. Thu ratinx cun.idu7w healing, cooling
and watur hunting and aaaumus avuragu wcaihur, thumoxint setting's, and quantitics orbot water for a typical huusuhuhl. Actual anergy my will vgry aaording
to ooeUpant Dohavior. Thim Rating ('A,mpluti,m Surnmary is Pmvidad only aIlcr the features 16(%W havv bvuu vLxiriul and appmvul by the Cal(:ERTS r..ertirtcd
loiter shown atiovu. If you save a eon= lir complaint. regarding I Ns ruport lir the xmices used In obt MMS It. you may coated: COIC1.14TH -t"4s41mLr
Page 19
Windows
Heating cmc;{ (.holing Systems
..Proposed Actual
Heating Equipment: Furnace: 0.8
Cooling Equipment: AC' I2
Orientation Area U U
SHGC SIIGC
Value
Value
NY'AC Air JAwrihution
Duct Location: Attic -
Duct Leakage l'arget: 6.0
Duct insulation R -Value: 4.2 =TESTED
APPROVED A$ PART OF SAMPLE GROUP (pg t of 1)
Air 1r2fi1trut1( FIRM: BCI TESTING
glower Door Target: 120.0. --
ADDRESS: 77-760 COUNTRYCLU13 DRIVE, SUITE I
PALM DESSERT, CA. 92211
Rier Heating Pro osed
PHaNE: 76o•r72•2954 .
QTY]Size Size Nuel I EFJ Distribution
Water Hea[in ..S stem Aclua! CERTIFYING SIGNATURE DA
TY Size_ Fuel I Fes 1, Distribution
kiting Rusuhs
Associated to Group #10108
*Ibc energy ci ieiency retiug ofthis homu.ie dctcxminud using! t :alili,mip I Imme Knorgy Raling System (C -HERS) rulua. Thu ratinx cun.idu7w healing, cooling
and watur hunting and aaaumus avuragu wcaihur, thumoxint setting's, and quantitics orbot water for a typical huusuhuhl. Actual anergy my will vgry aaording
to ooeUpant Dohavior. Thim Rating ('A,mpluti,m Surnmary is Pmvidad only aIlcr the features 16(%W havv bvuu vLxiriul and appmvul by the Cal(:ERTS r..ertirtcd
loiter shown atiovu. If you save a eon= lir complaint. regarding I Ns ruport lir the xmices used In obt MMS It. you may coated: COIC1.14TH -t"4s41mLr
Page 19
SEP 2,7,2005 16:56 BCI*TESTING,ril 000-000-00000
CaIC.ER'I'S Certified Rating September, 27 2005
This Compliance rating is for the home located at:
p 1;
43350 Parkway Esplanade East
Proposed
.Actual
La Quinta CA, 92253
Certificate Number:
CC3-1798350705
U
Value
Date Inspected:
September, 27 2005
!p_B
CaICERTS Rater:
William Henson
C
CC2004076
HERS Analyst:
R
Builder/Developer:
l,ennar 1 tomes
Project:
Tapestry (a), Esplanade
T
Plan Name:
Plan 1
S.
Lot Number:
081 — 19h6s"-. n --
Specifics about this home:
General lrlormalion
Buildup nvelu e
Conditioned Fluor Arca: 1806 Square Feet
Conditioned Volume: 0 Cubic Feet
Front Orientation: N/A
Number of Stories: i
Heating cold Cooling Systems
Heating Fquipment: Furnace: 0.8
Cooling Equipment: AC: 12
HVAC Air I NVrihulion
Dict Location: Attic
Duct Leakage Target: 6.0
Duct Insulation R -Value: 4.2
Air Infiltration
Blower Door Target: 120.0
Winer Howlin . s'lem llro oced
`I'Y I Size I Fuel I EF I Distribution
Wutcr. Heulirl r . sleet Acluul
TY I Size I Fuel I )Eb' I Distribution
Surface
Area
Proposed
.Actual
R U
Value Factor
R
Value
U
I Factor
Windows_
Orientation
Area
Proposed
Actual
SHGC
U
Value
SIIGC
U
Value
=TESTED
OAPPROVED A$ PART OF SAMPLE GROUP )pg 1 of 1)
FIRM: BCI TESTING
ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I
PALM OESEERT, CA. 92271.
PHONE: 760.772.2964
CERTIFYING SIGNATURE DATE
Page 19
&Yfing Results
Associated to Group #1010R—�--
the energy efficiency rating ofthis humu is dutmninud using t:alilnmi, Ilome Imorgy Rating System (GHERS) rulm.'niu rating can Bca4ng, cooling
and water la:ating and aasunu.7 avwagu wudhLr, thL,rnnwlat Uuin}x, and quantities ofhot water for a typical huu hull. Actual anergy uce wol vary according
to occupant behavior. This Rating (''Annpldion Summary is provided only :dlcr the fcaturus 16(e -d have bwv vvilied and appnrvul by Ibe (a1CI:R'I:C certified
Wticr shown atx)vc. Il'yuu have a concern or complaint reYanling chis ruptM ui tha Aervicrs uscd to oulnuung it. you may Coutacl: UalCEJU 5 - (:u.41mor