04-5862 (SFD)s' BUILDING & SAFETY DEPARTMENT
P.O..-Box 1504
- - I � (760).777-7012
c��rpF ti9�-7-8_4.95 CALLE TAMPICo FAX (760) 777-7011
Q LA QUINITX, CAL.IFORNIA.92253 INSPECTION REQUESTS (760) 777-7153'
AUG
2 1 2004 BUILDING PERMIT
r.,T.K.OF tA.QUINTA
Appl- jca,ti�OnT.Numb'er. . . . . 04-00+'005"8"620 Date 8/10/04
.e ! � +•+
Property Address _743;501 <PAR°KWAY ESPLANADE W
APN: :,609 "380, 99.7-33-293233-
Application descript'ion'. DWELLING SINGLE FAMILY DETACHED
Property Zoning ;. LOW DENSTTY RESTDENTIAL
Application valuation 2.0.1360
Owner Contractor
----------------------------.--------------------
;.
PONDEROSA HOMES II, LLC PONDEROSA.HOME,S II, INC.
400 S. F-ARRELL DRIVE, B103:.. 5671'-OWENS-DRIVE
PALM SPRINGS, CA 92264. PLEASANTON' CA 94588
LA QUINTA ''' ' "" CA -'•922:5 3. (7 6 0) 318.- 7 7110
WCC: REPUBLIC
WC: 156.71602 10/01/04
CSLB: 7=52,884: 08/31/04
CCC: 1B
--------------------- ---- Structure'InfQrmatdon. -------------------------
Constructon Type TYPE V -;NON RATED
Occupancy.Type . . DWELLG/LODGING/.LONG <=10;
Flood Zone NON-AO FLOOD ZONE
Other struct info . . . . . ..CODE EDITION 2001 CRC
# %=.BEDROOMS. 5.00
FIRE..SPRINKLERS NO
GARAGE: SQ °``F:TG 502.00
PATIO 'S.Q? FTG''` ' ` 500.00
NUMBER :SOF -=UNITS 1.00
FIRST FLOOR"SQ FTG. 3232.00-.
---------------------- -------.------------------_.---------------------------
Permi.t . . . BUILDING PERMIT
Additional desc
Permit-Fee 996.50 Plan Check Fee .647.73
Issue Date Valuation . . 201360
Expiration Date "2/10/05
Qty Unit Charge Per Extension
BASE`FEE 639.50
102.00 3.5000 THOU BLDG 100.,001-500;000 357.00
Permit MECHANICAL
Additional desc
Permit Fee 83. 5'0>" 'P 1 an 'C40ck Fee 20.88
Issue Date
valuation 0
P.O. Box 1504 • VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: Date:
Applicant: Architect or Engineer:
Applicant's Mailing Address: Architect or Engin
In er's Address:
Lic. No.: C -6.4-Q53
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my License= ' full force and effect.
/License Class dense No. �SZ
Date contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale: If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
ed. My workers' compensatio urance carrier and polic number are:
,,--carrierr�r,la4J L Policy Number /5fo?/ & OZ
I ceftify that, in The performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'
mpenOtion laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
orthwi comply with those provisions.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name //��
Lender's Address A
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have r ad this application and state that the above information is correct.. I agree to comply with all city and county ordinances and state laws relating to building
construction and h by authorize representatives of this county to enter upon the above-mentioned property for inspection purposes.
ate nature (Applicant or Agent):
Page
2
Applica,tion..Number .
. . . . 04-00005$62. Date
8/10/04
Expiration Date
2/10'/05
Qty Unit
Charge
Per
Extension
BASE
15.00
2.00
9.00 0.0
.FEE;
EA MECH FURNACE -<-_10:0K
18.00
2.00
9.0000
.EA'' MECH. B/C <=_2HP./;TOOK BTU
18.00
4.00
6.5'0.00
EA MECH .VENT FAN , '
26.00
1..00
6.5000
EA ;MECH EXHAUST•'HOOD
6.50
Permit
ELEC-NEW RESIDENTIAL:
Additional desc
Permit Fee.
138..1.6 Plan Check Fee
33.87
Issue Date
Valuation
.0
Expiration Date
.2 0/,05
Qty Unit
Charge.
Per
Extension
BASE FEE
15.00.
3232.00
.0350
EL;EC•NEW RES,- 1 OR 2 FAMILY
113.12
502.00
.0200
EIEC GARAGE OR NON-RESIDENTIAL
10.04
------------------------------------------------------------------------------
Permit . .
. .
PLUMBING
Additional desc..
Permit Fee
196.50. Plan-. heck Fee
44.63
Issue Date
Valuation
0
Expiration Date
2`/10%'0;5
Qty Unit
Charge
Per.
Extension,
BASE,.FEE
15.00
21.00
6-.0000
EA PLB-`FIXTURE
126.00
1.00 15.0000,EA
PLB BUILDING SEWER
15.00
1.00
7.5000
EA PLB` WATER ?H;EATER/zVENT
7.50
1.00
3.0000
EA " 'PL•B'_WATER'.INST/,ALT/REP
3.00
1.00
9". 0000_
`EA. PLB- LAWN, 'SP. RINKLER SYSTEM
9.00
8.00
.7500
EA PLB'.,:,GAS XP.IPE >=S
6.00
1.00 15.0000
EA PLB GAS -METER
15.00
Permit
GRADING PERMIT
Additional.desc
Permit Fee
15.00 Plan Check Fee
.00
Issue Date
Valuation
0
Expiration Date
2/1,0/05.,
Qty Unit
Charge'
Per
Extension
Page
3
Application Number_. . . . .. •°-04-00.005862. Date
8/10/04
Qty Unit Charge Per
Extension
,BASE FEE
15.00
Special Notes and Comment's
SFD - LOT' --33. :PLAN ,3AXL'+OPTION. BEDROOM
.
5 / BATH 4' (17 9 • • S F) . W / 2 CAR GARAGE' (GP RAGE
502 SF) PERMIT DOES NOT INCLUDE.;BLOCK
WALLS, POOL, SPA, OR DRIVEWAY APPROACH.
Other Fees . . . . . . ..• ART�'IN:,-P•UB'LIC;•-'PLACES,;-RES
20.00
DIF COMMUNhTY CENTERS -RES
97.0'0
DIF CIVI&:,CENTER - RES
366.00
EN°ERGY.REVIEW. FEE
64.77
DhF�FIRE PROTECTION; -RES
97.00
GRADING 'PLAN CHECK FEE
.00
DIF -'RES
225.00
..,LIBR:ARIES
DI°F PARK" MAINT 'FAC - RES
5.00
DIE PARKS RES
502.00
502.00
STRONG- MOTION• (SMI) - RES
19.46
' DIF STREET MAINT'FAC-RES
15.00
DIF' TRANSPORTAT.ION'` - 'RES
1098.00
Fee summary Charged PaidCredited,
Due
-- - - - - - - - - -.- - - - --=--=--'-------- - - - - ------ - - - - ----
-- -- - - - -
Permit Fee,Total'. 1429.66. 0.0.' .00
1429.`66
Plan Check Total 747.1.1 .00 .00
747.11
Other Fee Total 2509.23 .00 . r'' .00
2509.23
Grand• Total's 4686.00° .00 .0�0
4686.00
06/08/2005 14:51
P
9496312293
ACTION NOW MPH
PAGE 04
CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Tight Ducts & TXV) CF -4R
PROJECT INFORMATION Climate Zone: 15
Project Title:
Mosaic @ Esplanade
Project Address:
La Quints
Builder Name:
Ponderosa Homes
Voice 9: 925-460-8900
Builder Contact:
Jeff Nygren
Voice 4;
Project ID 0:
29323
Sample Group #:
Phase: 8
Lot #.
33
Plan #:
3
Address:4.3
501_Parl vveyiEsplanade;West
HERS INFORMATION
HERS Rater:
Scott Johnson Jayme Carden
Certification >x :
CCNSJ614037 CCNJC615157
HERS Firm:
Action Now
Voice # : 94931-2274
Address:
2575 Westminster Avenue, Costa Mesa, CA 92627
HERS Provider:
CHEERS
Voice # : 800-424-3377
HERS Address:
9400 Topangs Canyon Blvd.. Chatsworth, CA 91311
HERS RATER COMPLIANCE STATEMENT
exx T-24 Compliance Credit was Taken for Tight Ducts
T-24 Compliance Credit was Taken for TXV TXV Verlflad yes
The house was:
x Tested / Verfied =Approved as apart of sample, but was not tested
x The installer has provided a copy of CF -6R
x Air Distribution System is Fully Ducted (sheetmetal, ductboard or flex duct)
Where cloth backed rubber adhesive duct tape Is Installed. mastic and drawbands are used in combination with
doth backed, rubber adhesive duct tape to seal leaks at the connections.
MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT
Duct Diagno9tic Leakage Testing Results (Maximum 6% Duct Leakage)
CFA: CFA Leek Max OTasted Leak 0
System Of
Indicate the maximum a owa le Duct leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 6 through 15
0.5 x Floor Area x (0.08) for Climate Zones 1 through 7 & 16
x 400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacit in Thousands of Output BTU per hour) x
Measured Fan Flow x .06
Vu -a Pressurization Test Resu t9 5 PA)
100 K Test Leakage/ fan flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less) Pass
System Q of
Indicate the maximum a owa le Duct Leakage and the calculation used:
03 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zoites 1 through 7 & 16
x 400 x (Cooling Capacity In Nominal Tons) x (0.08)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x
Measured Fan Flow x .06
b-0 Pressurization Test Res u is 5 PA)
100 x Test Leakage/ fan flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less) Pass
System z of
m
Indicate the max mum a owa to Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons) x (0.08)
21,7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.08)
Measured Fan Flow 1 X.06
uct Pressurization Test Results 5 PA)
100 x Test Leakage/ fan flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less) Pa95Faill
Raters Certifying Signature
fan flow 0
Date 6/812005
F2001-02 (4-02) Action Now T-24CF4RTD&TXVmacro.xis
i'
wr
-:••A'i�.{AN.-/JINF..+.vrlliM•X�/.%/.'i'IIN/.'iGpLG71f//�Rf•CHw'/Y.W/y////N:%/.gfN7�SN�!/if7W�':llM,'�0(/1.%!U7f✓.a`S1LYi///•[JWA't�:�I?�NNl/N1_�A_.1: /.'.Y11w�.:•.:�./::.'�.:'A.'. ,(
l
's
INSULATION CERTIFICATE
This is to certify that insulation has been installed in conformance with the current energy
' regulation, California -Administrative Code, Title 24, State of California, in the budding at
43-501'PARKWAY-ESPLANADE. WEST, LOT 33, PHASE 8, LA QUINTA CA
CEILINGS:
TYPE: BATTS MAUNFACTURER: Certainteed THICKNESS: R-38
WALLS:
s TYPE: BATTS MANUFACTURER: Certainteed THICKNESS: R-13
GENERAL C RA R: PONDEROSA HOMES LICENSE #
BY: TITLE: J
PARAGON SCHMID BUILDING PRODUCTS A MASCO Company LICENSE * 221517
a
R BY: 4K TITLE: ACCOUNT REPRESENTIVE DATE:
a..ac(A i-a-YrA •ltlC:'Jh'-J-'•C!T `13��aa1.'�C�. YJIf�{`S'biw}-tiAYt J.1'rl'SL1mtJY41G11G'i�PY2At"��+r"•'ti.�'- ONAQmiiL:ilV-i67YYCiGi'As�tlY�LW' '.Q�-�•`�""•"°` �'.wDR.NO'�-Y�
/r ...:: V :•A•Al/+:'I.IY. %�•M/: U/ .: / /i/iW%_:'CiN.d9D'iR/YJ+W!/f.WI/✓/Nt/� �CN%/IhYNiil/iG'..vbN.V:ell'�✓/IXR'R�//NY/JYVyNlYI.aMI/1O•b•R'>J/tI47f/'.�l/.YJ/ice •I/.J : II•.:•/1l •I--'- .�-vy/
f -
INSULATION CERTIFICATE
r
This is
to. ' that insulation has been installed in conformance with the current energy
s regulation. Ca Administrative Code, Tide 24, State of California, in the buildir`ig`located ay-
{
CEILINGS.
TYPE: BLOW MAUNFACTU : CertainteedESS: R-38
WALLS:
TYPE: BLOW
GENERAL
BY -
THICKNESS: R-13
HOMES
SCHMID BUILDING PRODUCTS A MASCO Company LICENSE 1517
f
BY: TITLE: ACCOUNT REPRESENTIVE DATE:
.. �:/-i.•rr.•:..-.✓i:..--av-=i/.r.i•-::i-•.c:-n.i:rr. .oi i.v:-r/:'./o �%i://inui:-v-_ irtii�%tii x�ivr:/✓,ilii'://ivi,'i-�iinnnr.;/i.iii.:�.ai•::..:�..:/.'a•.:.v..:x�•:,:..•.:..-
r
HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 1 of 2
CF -611
Site Address: 43—.501 Fbirj My 5-pI4 n44eVWermitNumber.
Tract Number: Plan Number 3
Lot Number: 33 BED & BATH
An installation certificate is required to be posted at the building efts Or made avelible for all appropriate inspections.
After c4mpladon of final inspection, a copy must be provided to the Building Department (upon request) and the building
owner at occupancy, per Section 10-103(b).
HVAC SYSTEMS:
Heating Equipment
ii of Efficiency Duct Heating
Heating
Equip. CEC Certified Mfr Name Identicle (AFUE, etc.) location Duct Load
Capacity
Type and Model Name systems - (>= CF -1 R) (aft etc.) R -value (BTU / Hr)
(STY / Hr)
# of Efficiency Duct Cool -mg Cooling
Equip. CEO Certified Mfr Name Identice (SEER, etc.) Location Dud Load Capacity
TWO and Model Number Systems (--CF-IR) (attic, eta) R -value (BTU / Hr) (Biu / Hr'
effitdarrt than that gmclfled in the ceMticate of compliance (Fort CF -1 R) submitted for compliance with the Energy
Efficiency Standards for residential buftngs, and 9) equipment that meets or exceeds the appropriate requirements for
manor ctured devices (from th Appliance » ,Regulation or Pert 6), where applicable.
ALLIANCE MECHANICAL`$`igna re, Date T u(Co. are
HL
OR General Contractor (Co. Name) OR Owner
MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Ma)imum 6% Dud Leakage)
CFA:
System EM of r271
Indicate the maximum a15WAle Duct Leakage and the cal uletlon used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity In Nominal Tons) x (0.06)
21.7 x (Heating Capacity In Thousands of Output BTU per hour) x (0.06)
Other
Pressurization Test Results (CFM @ 25 PA)
100 x Test Leakage / Fen Flow = % Leakage
Check Box for Pass or Fall (Pass - 6% or Less) Passai
�T-24 Compliance Credit was Taken for TXV TXV was installed
y5 em =] of
Indicate the maximum a le Dud Leakage and the calculation used:
0.7 x Floor Area x (0.05) for Climate Zone 8 through 15
0,5 x Floor Area x (0.08) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity In Nominal Tons) x (0-06)
21.7 x (Heating Capacfty in Thousands of Output BTU per hour) X (0.06)
Other
D0 Pressurization Test Results (CFM @ 25 PA)
100 x Test leakage / Fan Flow = % Leakage
Check Box for Pass or Fall (Pass = 6% or Less) Pass a
QT --24 Compliance Credit was Taken for TXV TXV was Installed
PAGE 1
F2001-01 (402) Action Now T-24CF6-RTD&TXV macro