Loading...
BSOL2015-014678-495 CALLE TAMPIC(j%_ LA QUINTb, CALIFORNIA 92253 Application Number: BSOL2015-0146 I `&tyl 4 COMMUNITY DEVELOPMENT'DEPARTMENT BUILDING -PERMIT Property Address: 79718 N PARKWAY ESPLANADE APN:. 609610042 Application Description: WISEMAN / 14.51YtM46/ SYSTEF75)PANEL (2 1Property Zoning: Application Valuation: $32,210.75 11 205 P Applicant: SOLARCITY CORPORATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO,CA 94402 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: TERRENCE WISEMAN 79718 PARKWAY ESPLANADE N RS LA QUINTA, CA 92253 �LA QIIWTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 Business and Professions Code, and my Lic se is in full force and elle License la 46 B C10 A C20 Li :8 810 Date: • Contract : OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt froL Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3, of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I,'as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Contractor: SOLARCITY CORPOFATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO,CA 94402 (650)963-5630 Llc. No.: 888104 Date: 9/10/2015 il�q ft�'J I UZ-I I - WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate cf consent to self -insure for workers' Nr on, as provided for by Section 3700 d the Labor Code, for the performance for which this permit is issued`: have and will maintain workers' compensation insurance, as required by 0 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance -carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that of I s uId beco a subject to the workers' compensation provisions of Sectio C0 f th Labo C e, I shall forthwith comply wi h tho a provisions. Date: 1 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION CE GE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINA, PENALTIES AN VIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,0001 IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IV SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOW _EDGEMENT IMPORTANT: Application is hereby made to the 3uilding Official for a permit subject to the conditions and restrictions set forth on this zpplication. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performei under or pursuant to any permit issued as a result of this application , the owner,and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Cty of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this applica-ion becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that.) have read this application and sta at thea ve info tion is correct. I agree to comply with all city and county ordi nce nd at laws elat ng to building constructs n, and hereby authorize representa sates o ty o en r u on the above ment. necl prop fQr inspection purposes. Date: S Signature (Applicant cr A en FINANCIAL INFORMATION DESCRIPTION -, rt:: ACCOUNT ` "` QTY' �> r AMOUNT r_ ;- PAID ' .PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Wit -6 S PAID BY ?,s Y.y".„' �; a ° � ze a ; :RECEIPT # r w CHECK # CLTD BY. J Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $0.00 b” *`�` - ESCRIPTION z.v , , y 'ACCOUNT " { ; 'QTY;;, :. AMOUNT" PAID PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 r, L ;PAID BY = ;r ° . �, r ,i METHOD - RECEIPT # _, CHECK # = '_' CLTD BY Y -DESCRIPTION'ACCOUNT S _ .: S �Q TY "' ;AMOUNT ' Y PAID a.., PAIDbATE PV SYSTEM - ARRAY, FIRST 20 PC - 101-0000-42600 0 $24.17 $0.00 PAID' BY� Y. < ',1.t n METHOD _', 3. RECEIPT # ''i,R — CHECK # aC LTD BY," DESCRIPTIONr�'• *`v3' ` `ACCOUNTS '' QTY AMOUNT' k'` PAID fPAIDDATE PV SYSTEM - MISC EQUIPMENT 101-0000-42403 0 $24.17 $0.00 < tPAID BY -{° e; METHOD "�;' '' :RECEIPT'# k ,' r ti 1 . CHECK# CLTD BY;, DESCRIPTION ,? `'*} f 1 , ,< 'ACCOUNT 'QTY. 'AMOUNT PAID ` PAID DATE ` PV SYSTEM - MISC EQUIPMENT PC 101-0000-42600 0 $24.17,+ $0.0Q PAID BY _ METHOD. ` , , , " RECEIPT# CHECK # . _ CLTD BY ' Total Paid for ELECTRICAL: $96.68 $0.00 DESCRIPTION a _ �i4C000NT %CITY'' ."� AMOUNT' PAID . =,PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 } . PAID BY ��' • X; `: a ` : METHOD u ', + _ ' �H ItECEIRT,#, a ,, _' CHECK # CLTD`BY' Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TO190.53• •• 6 - OF. Description: WISEMAN / 14.5kW PV SYSTEM — (55) 265W PANELS/(2) INVERTERS Type: SOLAR Subtype: Status: APPROVED Applied: 8/21/2015 SKH Approved: 9/9/2015 AOR Parcel No: 609610042 Site Address: 79718 N PARKWAY ESPLANADELA QUINTA,CA 92253 Subdivision: TR 29323-2 Block: Lot: 65 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $32,210.75 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 14.5kW SOLAR ARRAY - (55) 265W KYOCERA PANELS W/ (1) ABB PVI -5000 AND (1) ABB PVI-600-OUTD-US-Z-A INVERTERS AND (1) 125A SUBPANEL, INCLUDING DERATING OF MAIN BREAKER [990SF] 2013 CALIFORNIA ELECTRICAL CODE. 19 ° J Applied to APProved Printed: Thursday, September 10, 2015 9:19:20 AM 1 of 3 C SYSTEMS ADDITIONAL CHRONOLOGYTYPE, ,7STAFF NAME > ACTION.DATE COMPLETION. DATE -NOTES 1 • ; ' y^ � .; z ,• -, Y � EMAIL SENT TO ELENA LOYA WITH SOLAR CITY E-MAIL AJ ORTEGA 9/3/2015 9/3/2015 (ELOYA@SOLARCITY.COM) THAT PLANS ARE READY FOR CORRECTIONS. EMAIL SENT TO ELENA LOYA WITH SOLAR CITY E-MAIL AJ ORTEGA 9/9/2015 9/9/2015 (ELOYA@SOLARCITY.COM) THAT PLANS ARE READY TO ISSUE, PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 8/21/2015 8/21/2015 . RECEIVED a CONDITIONS "„ :. _ NAME ''; ,` .. ADDRES51- CITY STATE F ', ZIR FAX wyNAMETYPE ,. �`' .+� rPHONE APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 CONTRACTOR SOL•ARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 Printed: Thursday, September 10, 2015 9:19:20 AM 1 of 3 C SYSTEMS 1 • NAME TYPE . Y ' ;NAME ADDRESSl " CITY' 7 STATE ZIP PHONE ? FAX t �'JEMAIL ,* k°t OWNER TERRENCE WISEMAN 79718 PARKWAY LA QUINTA CA 92253 ESPLANADE N INSPECTIONS PARENT PROJECTS Printed: Thursday, September 10, 2015 9:19:20 AM t 2of3 FINANCIAL INFORMATION, CLTD "DESCRIPTION . ACCOUNT .', QTY -AMOUNT ,. PAID PAID DATE RECEIPT # -;CHECK # METHOD, PAID BY BY,., BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $2.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC PV SYSTEM - MISC 101-0000-42403 0 $24.17 $0.00 EQUIPMENT PV SYSTEM - MISC 101-0000-42600 0 $24.17 $0.00 EQUIPMENT PC Total Paid for ELECTRICAL: $96.68 $0.00 PERMIT ISSUANCE 101-0000-42404- 0 $91.85 $0.00 Total Paid forPERMIT ISSUANCE: $91.85 $0.00 TOTALS:•000 INSPECTIONS PARENT PROJECTS Printed: Thursday, September 10, 2015 9:19:20 AM t 2of3 ^ . ` ` . . . ' . - Printed: Thursday, September 1lZO15g:19:ZOArm ' 3of3 - ORTEGA 8/21/2015 8/28/2015 9/2/2015 REVISIONS REQUIRED �AJ SEE ATTACHED REDLINES AND CORRECTIONS LIST2ND BLDG NS (1 AJ ORTEGA 9/8/2015 9/15/2015 9/9/2015 APPROVED 1ST REVIEW DOC 9/2/2015 AJ ORTEGA REVIEW ^ . ` ` . . . ' . - Printed: Thursday, September 1lZO15g:19:ZOArm ' 3of3 - BOND INFORMATION ATTACHMENTS 8SOL2015-0146 - 1ST 1ST REVIEW DOC 9/2/2015 AJ ORTEGA REVIEW CORRECTIONS BSOL2015-0146 - 1ST DOC 9/2/2015 AJ ORTEGA 1ST REVIEW REDLINES ^ . ` ` . . . ' . - Printed: Thursday, September 1lZO15g:19:ZOArm ' 3of3 - y Bin.# Cit}r. Of . Quit% BulkUng 81 Safety Division P.O. Box 1504,"78-495 Calle Tampico La "Qulnta, CA 92253 -:(760) 777-7012 Iq CP Building Permit Application and Tracking Sheet Pemiit # S� 0 Project Add, Uga, !fAdd,ess:Lege[ er's Name: . A. P. Number. Description: , ST, zip: La Quinta, CA Contr=ctor SOlar City - Telephone: ' Address: 3055 Clearview Way. Proje'gD criptio-55- roof mounted solar panels . city, ST, Zap: San Mateo," CA, 94402 inverter(s)' S Telephone: 650-638-1028 ' State Lia # : 888104 City Lia #' Atch., Eng-, Designer Address: City, ST. Zip. Telephone: Construction Type:. Ocarpanc r - Project type (circle one): New Add'n Alter Repair Demo State Lia #: Name of contact Person: Elena LOya Sq. Ft.: #Stories # Unity: Telephone # of Contact Person: (442)256-1134 Estimated value of Project Z 12410 - APPLICANT: DO NOT WRITE BELOW THIS LINE it Submittal Req'd Recd TRACIMG PERMIT' FEES Plan Sem Plan Check submitted Item Amount Structural Coles. Reviewed, ready for corrections Plan Check Deposit. . Trolls Calcs. Called Contact Person Plan Check Mance" Title 24 Cala. Plans picked up Construction " Flood plain plan Plans resubmitted.. Mechanical Giadiag plan V Review, ready for corrcctionsfissue Electrical Subeontactor list Called Contact Person Plumbing Great Deed Plans picked up SALL ILO.A. Approval Plans resubmitted Grading DV HOUSE.- ''d Review, ready for correcdo a eveloper Impact Fee Planning Approval Called Contact Pe—n(A AIP.P. Pub. Wlrs. Appr Date of permit issue School Fees Total Permit Fees ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE/ DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED. GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ELECTRICAL NOTES 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS.MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH. UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. LICENSE GENERAL NOTES CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: La Quinta UTILITY: Imperial Irrigation District CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB -92'24171 0 0 CONTAINED SHALL NOT BE USED FOR THE PV2 BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook PART TO OTHERS OUTSIDE THE RECIPIENT'S PV4 ON WITH TTHHE�SALE AND USES OF IN RES CECTVIE MODULES (55) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PERMISSION OF SOLARCITY INC. Multiple Inverters JURISDICTION NOTES ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE WISEMAN, TERRY 79718 PARKWAY ESPLANADE N LA QUINTA, CA 92253 APN:609610042 (760) 710-7996 VICINITY MAP WISEMAN RESIDENCE 14.575 KW PV ARRAY PAGE NAME COVER SHEET SLAI&-k C-0 et Cr ON OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE -q4 O1,0 I S BY jq.c KW fR S-48T&M W Iia spa ,. *uo M*ss4 PA4AJSL DESIGN: PV1 COVER SHEET DATE PV2 SITE PLAN A PV3 STRUCTURAL VIEWS Fuse all combined strings PV4 STRUCTURAL VIEWS 09/03/201 PV5 UPLIFT CALCULATIONS Joyce L PV6 THREE LINE DIAGRAM e PV7 ELECTRICAL CALCULATIONS PV8 ELECTRICAL ONE LINE DIAGRAM PV10 ELECTRICAL LOAD CALCULATIONS Cutsheets Attached 0 • REV BY DATE COMMENTS REV A NAME DATE COMMENTS A Joyce L 09/03/201 Fuse all combined strings B Joyce L 09/03/201 Change wire size to #4 C Joyce L 09/03/201 Change conduit size to 1" e . e Lin SHEET: REY: DATE:- PV ATEPV 1 a 8/13/2015 55 olarCity �► ha LN - Digitally Digitally signed by Matthew W. Bailey P.E. Date: 2015.09.05 10&1:23 -06'00' r �R TRANSFORMER INFORMATION: KVA PHASE HIGH KV LOW 120/240V —METER#** "PROPO BI—DIRECTIONAL METER 140 *DISCOMST—BRAND—MODEL — AC D NNECT: CUTLER-IAMMER #DG222URB **FT FIMAIN PANEL:1' — ITV vL M. *MODEL• —3.0 *BRAND: ABB 00 CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J13-9224171 CONTAINED SHALL NOT BE USED FOR THE MOUNTING SYSTEM: ZEP Mighty Hook I W • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN "IDLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES: (55) KYOCERA # KU2656ZPA "'W" SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INVERTER Multiple Inverters 79718 Parkway Esplanade N 00 mmbt UeNrx: WISEMAN, TERRY 79718 PARKWAY ESPLANADE N LA QUINTA, CA 92253 (760) 710-7996 WISEMAN RESIDENCE 14.575 KW PV ARRAY PAGE NAME SITE PLAN PITCH: 20 ARRAY PITCH: 20 MP1 AZIMUTH: 359 ARRAY AZIMUTH: 359 MATERIAL: Low Profile W -Tile STORY: 1 St PITCH: 20 ARRAY PITCH: 20 MP2 AZIMUTH: 269 ARRAY AZIMUTH: 269 MATERIAL: Low Profile W -Tile STORY: 1 St PITCH: 20 ARRAY PITCH: 20 MP3 AZIMUTH: 179 ARRAY AZIMUTH: 179 MATERIAL: Low Profile W -Tile STORY: 1 St PITCH: 20 ARRAY PITCH: 20 MP4 AZIMUTH: 89 ARRAY AZIMUTH: 89 MATERIAL: Low Profile W -Tile STORY: 1 St LEGEND - (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS FAC AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS 0° DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR �•��► CONDUIT RUN ON INTERIOR GATE/FENCE O HEAT PRODUCING VENTS ARE RED L'J INTERIOR EQUIPMENT IS DASHED SITE PLAN N • III FROM S `r Lin T.- I. SHEET: REV: DATE- PV ATEPV 2 a 8/13/2015 =; SolarCit . y 3055 Clearvlew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcitycom SIDE VIEW OF MP1A NTS . (A� MP1A X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" 48" 48" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI 359 PITCH 20 STORIES: 1 359 PITCH 20 Low Profile W -Tile 1 C SIDE VIEW OF MP2 NTS MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" 48" 48" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2x4 @24" OC ROOF AZI ARRAY AZI 269 PITCH 20 STORIES: 1 269 PITCH 20 Low Profile W -Tile ZEP SPANNER BAR " DIA BOLT & NUT ZEP SPANNER BAR CLAMP STANDOFF •(E) TILE t . (E) ROOF DECKING — 5/16" DIA STAINLESS STEEL LAG BOLT (2-1/2" EMBED, MIN) (E) RAFTER B SIDE VIEW OF MP1B NTS MP1B X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 1 24" 48" 48" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI 359 PITCH 20 STORIES: 1 359 PITCH 20 Low Profile W -Tile (6) (1)'—\ F (2)I I �V (� (3) (5) (4) LOWEST MODULE SUBSEQUENT MODULES 4STANDOFF Scale: 1 1/2" = 1' INSTALLATION ORDER LOCATE RAFTER, MARK RAFTER LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER LOCATION. Q2) CLEAN PAPER AROUND PILOT HOLE. (3)1 ADJUST STANDOFF TO BATTEN HEIGHT. SEAL PILOT HOLES AND BOTTOM (4) OF STANDOFF WITH POLYURETHANE SEALANT. 5) LAG STANDOFF INTO RAFTER. 6) NOTCH TILE WE TO FIT AROUND STANDOFF. 7) REINSTALL TILE. _ CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: - JB -9224171 0 0 PREMISE OWNER: DESCRIPTION: WISEMAN, TERRY WISEMAN RESIDENCE DESIGN: Joyce Lin NIA ■ �..e MOUNTING SYSTEM: ZEP Mighty Hook BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 79718 PARKWAY ESPLANADE N 14.575 KW PV ARRAY �j,,SOIa�City: PART TO OTHERS OUTSIDE THE RECIPIENT'S LA QUINTA, CA 92253 MODULES 3= aearNew way San Mateo, CA 94402_ ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (55) KYOCERA # KU2656ZPA. PAGE NAME SHEET: REV DALE ImultipleInverters THE WRITTEN PERMISSION OFITY ISOLARCITY INC. 76O 710-7996 ) STRUCTURAL VIEWS PV 3 a 8 13 2015 / / (m)-soL�arr (69-2489) ww.sclarci�com SIDE VIEW OF MP4A NTS MP4A X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE .48" 24" 48" 24" ARRAY AZI PORTRAIT 1 48" 1 20" 48" 24" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI 89 PITCH 20 STORIES: 1 89 PITCH 20 Low Profile W -Tile ZEP SPANNER BAR —\ DIA BOLT &NUT (2) I L (Z) (3) ZEP SPANNER= �l I STANDOFF J (E) TILE (E) ROOF DECKING (5) (4) 5/16" DIA STAINLESS STEEL LAG BOLT (2-1/2" EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES (E) RAFTER 1 STANDOFF Si Scale: 1 1/2" = 1' INSTALLATION ORDER LOCATE RAFTER, MARK RAFTER LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER LOCATION. 2) CLEAN PAPER AROUND PILOT HOLE. q ADJUST STANDOFF TO BATTEN HEIGHT. SEAL PILOT HOLES AND BOTTOM (4) OF STANDOFF WITH POLYURETHANE SEALANT. 5) LAG STANDOFF INTO RAFTER. 6) NOTCH TILE WEATHERING TO FIT AROUND STANDOFF. 7) REINSTALL TILE. CG SIDE VIEW OF MP4B NTS MP4B X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" 48" 48" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC ROOF AZI 89 PITCH 20 STORIES: 1 PART TO OTHERS OUTSIDE THE RECIPIENTS ARRAY AZI 89 PITCH 20 BOT CHORD 2X4 @24" OC MODULES Low Profile W -Tile E SIDE VIEW OF MP3B NTS MP3B X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" 48" 48" 24" 24" _] PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC ROOF AZI 179 PITCH 20 STORIES: 1 PART TO OTHERS OUTSIDE THE RECIPIENTS ARRAY AZI 179 PITCH 20 BOT CHORD 2X4 @24" OC MODULES Low Profile W -Tile CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER:rKLmm JB -9224171 00 UwwtN: unuarNUN: WISEMAN' TERRY WISEMAN RESIDENCE UL51GN: Joyce Lin MOUNTING SYSTEM: ZEP Mighty Hook BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 79718 PARKWAY ESPLANADE N 14.575 KW PV ARRAY • " �;1`SOIarC't'e PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTI CA 92253 13055 MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (55) KYOCERA # KU2656ZPA r CIeaMew Wa W .. SHEET: REDATE PV 4 a 8/13/2015 SOLARCfTY EQUIPMENT, WITHOUT THE WRITTENPAGE PERMISSION OF SOLARCITY INC NAME (760) 710-7996 STRUCTURAL VIEWS T:(650) San Mateo. CA 94402 (650) 636-1029 (886) -SOL -cm (765-2489) www.solaraty.aam �� -Multiple Inverters VENT SPANNING DETAIL SOLAR PANEL i SOLAR MODULE MOUNTING HARDWARE (SEE STANDOFF DETAIL) ROOFING MATERIAL PLYWOOD (E) RAFTER SPANNING PHOTOVOLTAIC MODULES OVER VENTS NTS 2" MAX 2" MIN CLEAR SPAN DIAMETER _-4,TO UNDERSIDE OF MODULE MINIMUM VENT HEIGHT IS 6" ABOVE THE SURFACE OF THE ROOF PER 2007 CPC SECTION 906.1. 6" MIN. VENT HEIGHT FROM TOP OF ROOFING MATERIAL VENT PIPE 2013 CPC 310.5 STATES 'NO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, DEVICE, OR METHOD OF INSTALLATION THAT OBSTRUCTS OR RETARDS THE FLOW OF WATER, WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS IN AN AMOUNT EXCEEDING THE NORMAL FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED AS ACCEPTABLE IN THIS CODE OR IS APPROVED IN ACCORDANCE WITH SECTION 301.1 OF THIS CODE." FROM THIS SECTION, IT IS CLEAR THAT MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT WILL NOT HAVE A GREATER FRICTIONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE. EQUATIONS: THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR CAN FLOW THROUGH. IN THE VENT, THAT IS THE CROSS-SECTIONAL AREA OF THE VENT PIPE: Avent = 7T*R' WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF THE VENT TIMES THE VERTICAL DISTANCE BETWEEM THE VENT AND THE MODULE ABOVE (IN THIS CASE, WE ARE LEAVING THE DIAMETER BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE PANEL). THIS METHODOLOGY ASSUMES THE WORST CASE SCENARIO OF MOUNTING THE MODULES HORIZONTALLY OVER THE VENT. IN ACTUALITY, .THE MODULES WILL BE TILTED WHICH WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH. Agap = C*CLEARANCE = (7T*D)*D = (7T*2*R)*(2*R) = 4*IT*R2 4*IT*R2 > WR' FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER ALLOWS FOUR TIMES THE AMOUNT OF AIR FLOW ABOVE THE VENT THAN IN THE VENT ITSELF. VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE ALLOWED BY LOCAL BUILDING CODE. MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE SOLAR MODULE GLASS SHALL BE AT LEAST THE DIAMETER OF THE VENT. IN THE DIRECTION OF THE SLOPE OF THE ROOF, THERE SHALL BE A GAP OF AT LEAST 1/2 INCH BETWEEN MODULES. THE ROOF SLOPE MUST HAVE A MINIMUM INCLINATION OF 10' OR THE PANELS MUST BE SLOPED AT A MINIMUM INCLINATION OF 10'. UPLIFT CALCULATIONS .07.30.2015 D ■ Version #48.9. Q oo;SolarCity. PV System Structural Desi a n SOftva re "ect Information &Table Of Contents fiisk Category: N ' SolarCity II BENEFIT OF ANYONE EXCEPT SOLAROTY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PV=SysEerti Type to _ Sola6biy SfeekMount" PART TO OTHERS OUTSIDE THE RECIPIENT'S Spanish T11e_Roof� '= "ers of'Com Aoo06 Spanish TiledfRo DULES: 3055 ClearNew Way Son Mateo, CA 94402_ ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE RoofMSlope ' PAGE NAME 20° SHEET: REV. DATE 0ffeiS adn SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 24"— PV 5 a 8/13/2015 PVyS.ystem Module;OnenYation�— PV Module Ares: _ Langsc_ap and Portrait _ 514T PV Module. Width 39" 6s"f,1 1111.1 ''1 I., I I .. , .. Standoff Attachment Hardware SM Tile Reduced Ground/Roof Live/Snow Loads Ground Snow Load. - 0.0 psf. 0:0 psf ; ASCE Table 7-1 _ASCE Eq: 7:4 1 Surroundtng_Roof Snow Roof Snow Over PV Modules 0.0 ASCE Eq: 7.4-1 Wind Design Criteria Wind.Desidn Code' ASCE 7-10 *nd Design' Method _ Partially%Fully Endosed Meod Basic Wind Speed . 110 mph. `Fig.26_54A Exposure Category _ Roof Style " Mean Roof He�tit _ Effective Wind Area 4 Module " ": pg _ _ C Sgdfon 26.7 Gable Roof >" 15 ft `'� 17.7 sf' _ ASI :30 4 2A/8/C5A/B Section 26t.2~.^ IBC 1509.7.1 'Wind Pressure Calculatton,Codfents,�, Wind Pressure Exposure-,_,_ Dlredionality Facto Im ortance`Fador - _ . `,' 0.85 _ _Topographic:Faetor!�0on268'VHnd 0.85 _ Table 30.371 _ Section 16.&1 NA Velocity Pressure qh �K qh. = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 Equation 30:3=1 ExG Pressure CoefHdent (Up) -"` ExL Pressure Coeffldent Down~ � GCp`(UP) '` G Down =� 0:88 ny.3o 4=zA/e/csA/0 0.45 rg.,3o:4-2A/8/C,5P48 Desion Wind Pressure = h GC E uation'30.4-1 Mod PPre Wp Up _p(uP) -19.66;vsf Wind Pressure Down' down 16.0 psf Allowable Standoff Spagings X -Direction 9 -Direction Max Allowable Standoff Spadng_ Landscape 48" 39" Max Allowable Carrtllever Undscape _ 24" NA_ Staindoff.confl uration Landscape Not-Sta gered. Max 5tandoffTrlbutaary Area PV Assembly Dead Load NetWR_ UpliRatStandoff� ,A Trib 13;sf W -PV T-a,...ach1al1311bs 3 psf Uplift Capadty of Standoff T -allow 446 lbs _ Standoff Dernand/CapadtV, DCR. 293% Max Allowable Standoff Spadng^ Portrait .48" 65" Max�Ailowablg_C�ntileVer �Forfrdlt__ 19" _ NA, Standoff Configuration Portrait.Not-Staggered Max Standoff Tributary Area Trib _ _. 22 91" PV Assembly Dead Load _ Ne Mn -d Up,iff i t'S4 doff _ W-pV ' �T-aiti.0 _ 3 Psf _ �y -219 lbs Uplift Capacity of Standoff T -allow 446 Itis Standoff DemandCa a DCR 49:1% CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB -9224171 0 0 PREMISE OWNER: DESCRIPTION: WISEMAN, TERRY WISEMAN RESIDENCE DESIGN: Joyce Lin N ' SolarCity MOUNTING SYSTEM: ZEP Mighty Hook BENEFIT OF ANYONE EXCEPT SOLAROTY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 79718 PARKWAY ESPLANADE N 14.575 KW PV ARRAY to �„e �r • PART TO OTHERS OUTSIDE THE RECIPIENT'S LA QUINTA CA 92253 DULES: 3055 ClearNew Way Son Mateo, CA 94402_ ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE 55) KYOCERA # KU2656ZPA rlT ' PAGE NAME SHEET: REV. DATE R'76O Multiple Inverters SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 710-7996 UPLIFT CALCULATIONS PV 5 a 8/13/2015 029 (888)SOL'CITY (765-248 638-1028 (9) www.solaricity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #6 GEC TO (E) LIFER AT PANEL Panel Number: TSM2020CSCU Inv 1: DC Ungrounded INV 1 -(1)ABB PN-5000-OUTD-US-Z-A - (55)KYOCERA # KU2656ZPA CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number: 1B4SR-145177 Inv 2: DC Ungrounded AFCI nverter, Zigbee 5000W, 277V/24OV/208V, 96.5%/96.5%/96Y: PV Module; 265W, 238.1W PTC, 40MM, Blk Frm, H4, ZEP, 1000V, Blk Cell, o Backbar C-10 Underground Service Entrance Downsizing Main Breaker For Tie -In INV2 -(I)ABB PN-6000-OUTD-US-Z-A ! AFCI Inverter, Zigbee 6000W, 277V/24OV/208V, 96.52/96.5%/96% Voc: 38.3 VpmOx: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL N 150A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! CUTLER -HAMMER BRYANT (N) 125A Load Center Inverter 1 IND Vstart = 200V N)150A/2P Disconnect 7 5 ABB + PVI-5000-OUTD-US-Z-A Da MP 1: 1x9 (E) LOADS A B 30A/2P L, zaav r-------- EGC ---- - 2 -------- - ----� V rt = 2DDV L2 pC+ Dc, 70A/2P _ _ _ _ GND jAf - - -, c r ------------------------- N DG I EGCI DC - GEC ---TN DG 4 C+ GMP4: M x9 1 I I = GND -- E --- ----f-- -- GC -----� � � J ADJUST MIN. ACTIVATION OLTAGES! (1) COf1DUIT KIT 1 x 10' EMT Conduit " Inverter 2 IND s Q�oFessroro o - - - EGGGEC - Z i 6 ABB PVI-6000-OUTD-US-Z- Do• Dc VStart = 200V SEW MP 4: 1x1 " GEC i 35A/2P I Ll zaav r- - - - - - - -- _ ecc____________ 4Dc+ ____� E19 T o� I 31 �G - - _ - - TO 120/240V i I I i L2. I N Dc I a VStdrt = 200V EXP MP 2: 1 Sr �� CTRICP� SINGLE PHASE I L EGG Dc+ C+ I UTILITY SERVICE I - - - - - - - - - GEC - - T N Dc c MP 3: 8 CA��F I� GND -- EGC- - ----f-- -- GC -- - - - - -� I (1) CODUIT,KIT ' CITY OF LA QUINTA ' x'°EM T°°nd"" Digitally signed BUILDING &SAFETY DEPT. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTI D by Matthew W. APPROVED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL B FOR CONSTRUCTION PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF Bailey P.E. GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST DATE BY ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. Date: 2015.09.05 PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE 10:51:33 -06'00' Voc* = MAX VOC AT MIN TEMP INSTALLED ONLY BY QUALIFIED PERSONS /A\ POI (')GE Q THOL2170 PV BACKFEED BREAKER Breaker, 70A/2P, 2 Spaces A (1)CUTUER-HAMMER # DC323URB Disconnect; 100A 240Vac, Non -Fusible, NEMA 3R /f A -(g)Shoals STG.ILF.15.H4 Inline fuse and holder; 15A, H4, Unserviceable, Weatherproof D� - (1) Ground Rod; 5/8' x 8', Copper - (1) CUTLER- AMMER DG100NB Ground%Neutralt 60-100A, General Duty (DG) B (I)BRYAN T 8 BR48L125RP Load Center, 125A, 120/24OV, NEMA 3R i - (I)CUTLER-HAMMERBr Breaker. OA2P, 2 Spaces - (1) Breaker,H35A/2P, 2 Spaces 7 1 AWG 84, THWN-2, Blade (1) AWG 84, THWN-2, Red j� 1 AWG 810, THwN-2, Black (1) AWG 810, THWN-2, Red O 2 AWG 810 PV Wore 600V, Bloe* Voc* = 388.13 VDC Isc = 9.26 ADC O (1) AWG 810 THHN/THWN 2, Green EGC Vmp = 279 VDC Imp= 8.55 ADC (1)AWG 84, THWN-2, White NEUTRAL VM =240 VAC Imp 1 AAC - (1)AWG {6,• TFiWN-2,. Gre• EGC/GEC - ( )CQ)dDUIT KIT 7 ie'1O' EMT Cbeidui' L`L (1)AWG 810, THWN-2, White NEUTRAL Vmp =240 VAC Imp=23 - (1 AWG 86,. TFtWN-2,. Green . , EGC/GEC • . (1) Conduit. Kit;. 3/4'.EMT......... (1 )AWG 88, THWN-Y, Blade AAC (1 Condwt Kit. 3/4 .EMT (4 AWG 010, PV Wire, 60OV, Blade Voc* = 388.13 VDC Isc = 9.26 ADC O (1)AWG 810, THHN/THWN-2, Green EGC Vmp = 279 VDC Imp= 8.55 ADC 1 AWG THWN-2, Red () 88 © (1 Conduit Kit 3 4 EMT / .......................................... LCL (1)AWG 810, THWN-2, White NEUTRAL Vmp =240 VAC Imp=28 AWG 86,, THW472,. Green TPP/9P.7 (1) Conduit• Kit;. 3/47. EMT AAC (2 AWG 010, PV Wire, 60OV, Blade Voc* = 517.51 VDC Ise = 9.26 ADC O (1) AWG810, THHN/THWN-2, Green EGC Vmp = 372 VDC Imp= 8.55 ADC B .70 .. .., ..... , , (1 Conduit Kit;. 3/4'. EMj • • C O (4) AWG 810, PV Wire, 60OV, Blade Voc* = 345.01 VDC Isc = 9.26 ADC 4 lay- (1) AWG 810, 7HHN/THWN-2, Green EGC Vmp = 248 VDC Imp= 8.55 ADC CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BEE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARgTY INC., JOB NUMBER:PREMISE JB -9224171 00 OWNER: DESCRIPTION: WISEMAN, TERRY WISEMAN RESIDENCE 79718 PARKWAY ESPLANADE N DESIGN: Joyce Lin �'•,.c �SolarCity. MOUNTING SYSTEM:[- NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 14.575 KW PV ARRAYail • PART OTHERS THE RECIPIENTS LA QUINTA CA 92253 MODULES 30ss gemlee way San Mat CA W02 EPT IN ORGANIZATION.EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (55) KYOCERA # KU2656ZPA , PAGE NAME SHEET: REV: DATE 1N1Q21°z Multiple Inverters SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION of SOLARCITY INC. (760) 710-7996 THREE LINE DIAGRAM PV 6 a 8/13/2015 (eo, T;(�O) 8 F:(650) 638-1029 888) -SOL -CITY (765-2489) a nx.solarcity.can ELECTRICAL CALCULATIONS Module: 27 Kyocera 265W 1000V 238.1 Inv Power Digitally signed by Matthew.W. Bailey P.E. 0.96 5000 Date: 2015.09.05 Inverter 1: 10:51:4.2 -06'00' Vdrop =(imp) 2.' Lenqt sistance/ mp) CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER JB -92241 71 O 0 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ZEP Mighty Hook ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES: (55) KYOCERA # KU2656ZPA . SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INVERTER Multiple Inverters Module: 27 Kyocera 265W 1000V 238.1 Inv Power WPTC Voltage Drop. Calculations Version 5_8.0 1 ABB PVI -5000-5 AFCI 0.96 5000 6203.7 Inverter 1: Vdrop =(imp) 2.' Lenqt sistance/ mp) 28 Kyocera 265W 1000V 238.1 Module: Im Wre Inverter 2: qAMax.&9P(fi) String. 8.580 AWG #10 at Max Ave Hi:109 deg F 1 ABB PVI -6000-5 AFCI 0.96 6000 6433.46 Module: Inverter 3: Module: Vdrop -8.551 0 0.00124 Ohms / 313.41 0.54 Branch: 8.550 AWG #10 at Max Ave Hi: 109 Vdrop = 8.55 0 Ohms) / 372 0.34 Totalvolts a dro in DC conductors = 0.88 Inverter: 28 10 . AWG #8 1 at 240V Vdrop = (28 20 _ 0.00078 Ohms) 240 V 0.06 Combined 40.8 15 AWG #6 1 at 240V deg F K ocera 265W 1000V 238.1 Kyocera 265W 1000V 238.1 Inverter 4: Total: 55 Modules Total Inv Pwr: 11000 112637.16 PTC Photovoltaic Module Electrical Specifications: Total STC:j 14575 Vdrop = 40.8 30 0.00049 Ohms) / 240 V 0.1 Voc: 38.3 V deg F deg C Vmp: 31 V Isc: 9.26 A Record LowTemp: 14 -10 Max Average Hi Temp: 109 43 1 Total voltage drop in AC conductors = 0.16 Total voltage drop in AC and DC conductors = F Imp: 8.55 A Record Hi Temp: Tvoc: -0.14 V/deg C Tisc: 5.56 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf TVoc Data Bran&Circuit Type A 1 way wire length: N/A Voc Correction Factor: 'ABB PVI -6000-5 AFCI Inverter Min Vdc Input: 12 Kyocera 265W 1000 Voc=459.6 _. Min Vmp,at Max Temp: Max Voc at Min Temp: Vmp= 372 Inverter Max Vdc Input: Isc= 9.26 Max String Size: Imp= 8.55 (cont= 11.58 Art 690.8(A)(1) 1 -way wire length: 2 strings per branch 1strings per branch 2 91 modules per series string 1 91M dules per series string Voc= 344.7 V Voc= 344.7 V Vmp= 279 V Vmp= 279 V Isc= 18.52 A Isc= 9.26 A Imp= 17.1 A Imp= 8.55 A (cont= 28.94 A (cont= 11.58 A Art 690.8(A)(1 130 313.41 517.51' 600 13 50 1.a Conductor: AWG #10 PV Wire 2.a Conductor 1: N/A Conductor 2: N/A (cont1.25 = (Amps) 14.47 . ' Conductors Conductor 30 deg C ampacity = 40T (cont' 1.25 = (Amps) 30 deg C ampacity = 36.17 14.47 N/A N/A 1.b Icont= (Amps) 11.58 2.b Icont= (Amps) 28.94 11.58 Start ampacity 40 N/A N/A Temperature derate (%=F) 0.41 Start ampacity N/A N/A Conduit fill derate (%_#) 1 Temperature derate (%=F) N/A N/A Derated ampacity 16.4 F Conduit fill derate (%_#) Derated ampacity 1.0 N/A I N/A 2.c Term 1 Term 2 Icont' 1.25 = (Amps) 14.47 Ampacity 40 Temp table N/A I N/A lcont'1.25= (AMPS) 36.17 14.47 Ampacity N/A I N/A 1.d Icont * 1.25 = (Amps) OCP Size = 14.47 15 Inverter Type A Output 1 way wire length: 10 ft Art 690.8(A)(1) 2.d OCP Size = 401 15 ABB PVI -6000-5 AFCI Combined Inverter Output Service Voltage= Total Inverter Powe - 1 way wire length= 15 (cont 1 28 JA 3.a Icont' 1.25 = (Amps) 35 Art 690.8(8)(1) 35 OCP Size = Art 240.6(A) (cont = # of inverters max inverter current Art (cont = (Amps) , 4.a Icont'1.25 = (Amps) 63.75 Art9y8(j) UF OCP size = 70 Art 4 4:b Conductor: AWG #4 THVVN-2 at 90 d g (cont' 1.25 = (Amps) 63.75 30 deg C ampacity = 75 I AF IPPR LA 3.b Conductor: AWG #8 Icont' 1.25 = (Amps) 30 deg Campacity = THWN-2 at 90 deg. C: Table 310.16 35 55 3.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 28 55 0.82 4.c ICont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 51 FOR GONST DATE 1 75 45.1 0.82 3.d Icont' 1.25 = (Amps) Ampacity 35 50 1 61.5 4.d Ioont' 1.25 = (Amps) 63.75 65 Ampacity 'REMISE OWNER: DESCRIPTION: WISEMAN, TERRY WISEMAN RESIDENCE 79718 PARKWAY ESPLANADE N 14.575 KW PV ARRAY. LA QUINTA, CA 92253 PAGE NAME (760) 710-7996. ELECTRICAL CALCULATIONS QUINTA FETY DEPT. VED UCTION DESIGN: Joyce Lin s ;SolarCity 3055 ClecNew Way SHEET: REV:DATE Son Mateo, CA 94402 - T:(650) 638-1028 F:(650) 638-1029 PV, 7 a 8/13/2015 (888) -SOL -CITY (765-2489) www.solarcitycom I EXISTING UNDERGROUND ELECTRICAL SERVICE ENTRANCE 200A 122 kAIC 1240V 1 PHASE 13 WARE (E) Load TO 120/240V SINGLE PHASE 1TILITY SERVICE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH CUTLER HAMMER III DG222URB 60A, 240VAC ELECTRICAL ONE LINE DIAGRAM AC COMBINER PANEL BRYANT / BR816LI25RP LOAD CENTER; 125A 120/24OV. NEMA 31? 30A/2P Digitally signed by Matthew W. Bailey P.E. Date: 2015.09.05 10:51:49 -06'00' AC DC 3000 WATT UTILITY INTERACTIVE INVERTER FCI INVERTER 240V, 96% ABB Y PVI-5000-OUTD-US-Z-A AC DC 3000 WATT UTILITY INTERACTIVE INVERTER FCI INVERTER 24OV, 96% ABB 11 PVI -6000 -WTD -US -Z -A PV ARRAY #1 9 MODULES KYOGERA # KU2656ZPA PV ARRAY #2 2 X 9 MODULES KYOGERA # KU2656ZPA PV ARRAY #3 12 MODULES KYOGERA # KU2656ZPA PV ARRAY #4 2 X 8 MODULES KYOGERA # KU2656ZPA 005010-200 1 2 AWG #10, PV Wire, 60OV, Black Voc* = 388.13 VDC Isc = 9.26 ADC (1) AWG #10, Solid Bare Copper EGC Vmp = 279 VDC Imp= 8.55 ADC O (1) Conduit Kit; .3/4' EMT (4) AWG #10, PV Wire, BOON, Black Voc* = 388.13 VDC Isc = 9.26 ADC O (1 ) AWG #10, Solid Bare Copper EGC Vmp = 279 VDC Imp= 8.55 ADC (1)AWG #6, THWN-2, Black (1 )AWG #10, THWN-2, Black (1 Conduit Kit; 3/4 EMT. O. (-L)AWG #6,-THWN-2i.Red._.. ......1 O 10� (1 )AWG #10, THWN-2, Red (2 AWG #10, PV Wire, 60OV, Black Voc* = 517.51 VDC Isc = 9.26 ADC j 1 111;8 (1 )AWG #6, THWN-2,-White NEUTRAL Vmp =240 VAC Imp=51 AAC l�L (I )AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=23 AAC O (1)AWG #10, Solid Bare Copper EGC Vmp =372 VDC Imp= 8.55 ADC ( ) Id h t 1 AWG LTHWN2,�Green`1EGC GEC - 1 Conduit Kit; 3 4 EMT - 1 AWG 1 Conduit Kit; 3 4- EMT I THWN-2, Green EGC GEC - 1 Conduit Kit; 3 4 EMT ) • • • • • • • • • / ........... • . .,.......... (.)....i ..... / .....(.)............ .......................... (. I ..................../.......).........../.�................. (4) AWG 0, PV Wire, 60OV, Black Voc* = 345.01 VDC Isc = 9.26 ADC 1c��q ��� ". �,� ,� v�;C7.�1-,1� } (1 nwc� #6, THwN-2, Black � �q�f'� ©ffp (1) AWG #8, THWN-2, Red (4) R[ (1) AWG #10, Solid Bare Copper EGC Vmp = 248 VDC Imp= 8.55 ADC =l V �..il � `• (1) AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp= 28 AAC v.. (1) Conduit Kit; 3 . . EMT .............................................. 001Tg1Jn rd Vi -0 f1i ......... - (1) AWG #6,_ THWN72, Green ... EGC/GEC - (1) Conduit Kit; . 3/4' EMT ......... . .. . CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9224171 MOUNTING SYSTEM: ZEP Miahtv Hook KYOCERA W KU2656ZPA Multiple Inverters 00 PREMISE OWNER: WISEMAN, TERRY 79718 PARKWAY ESPLANADE N LA QUINTA, CA 92253 (760) 710-7996 DESORPTION: WISEMAN RESIDENCE 14.575 KW PV ARRAY PAGE NAME ELECTRICAL ONE LIN Joyce Lin AM ISRLLI: �V*. DATE PV 8 0 8/13/2015 SolarCit . • y 3055 Cleamew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcity.com CAUTI.ON' POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 79718 Parkway Esplanade N INVERTER AND DC DISCONNECT INVERTER AND DC DISCONNECT UJ rl f UTILITY SERVICE -- - z f --------- Ac AC DISCONNECT YTI r------------------------- r r SOLAR PHOTOVOLTAIC ARRAYS) CITY OF�LA-QU.INTA t UG ------ J 6 r e +f, t Ir1d l -------------=--- BUILDING 9SAFETY DEPT . PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER . IN. MAIN ELECTRICAL PANEL _ APPROVE D •r #'tb) F1t�- IS AN A/C DISCONNECT PER NEC 690.17 FOR NSTRUCTION OPERATING VOLTAGE = 240V 31379224171-00 DATE _!'. r . UTILITY SERVICE -- - z f --------- Ac AC DISCONNECT YTI r------------------------- r r SOLAR PHOTOVOLTAIC ARRAYS) CITY OF�LA-QU.INTA t UG ------ J 6 r e +f, t Ir1d l -------------=--- BUILDING 9SAFETY DEPT . PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER . IN. MAIN ELECTRICAL PANEL _ APPROVE D •r #'tb) F1t�- IS AN A/C DISCONNECT PER NEC 690.17 FOR NSTRUCTION OPERATING VOLTAGE = 240V 31379224171-00 DATE _!'. CONFIDENTIAL — THE INFORMATION HEREIN ' CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER JB -9224171 0 0 PREMISE OWNER: WISEMAN, TERRY DESCRIPTION: WISEMAN RESIDENCE DESIGN: Joyce Lin SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN MOUNTING SYSTEM: ZEP Mighty Hook 79718 PARKWAY ESPLANADE N 14.575 KW PV ARRAY - ; .." j�� PART TO OTHERS OUTSDE THE RECIPIENTS MODULES LA QUINTA, CA 92253 4 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (55) KYOCERA # KU2656ZPA PAGE NAME ae�e. y son Mateo; CA 94402 SHEET., REV DATE THE WRITTEN PERMISSIONSOLARCITY EOFISOLARCITY INC. INVERTER: Multiple Inverters - � - C 76O 710-7996 ( � - SITE PLAN PLACARD PV 9 a 8/13/2015 89) �638-1029 (BBej SOLL CITY (7655-2F:(650) � ELECTRICAL CALCULATIONS Panel Schedule Load Breaker I VA Oven 40A/2P )i hwasher/Garbage Disposal 20A/2P 1500 Other 50A/2P 1500 Air Conditioner 50A/2P Laundry 20A/113 Bathroom 20A/113 Lighting Circuit 15A/113 Lighting Circuit 15A/113 Lighting Circuit 15A/113 Lighting Circuit 15A/113 Small Appliance 20A/113 CITY OF. LA QUINTA; _ - BUILDING &SAFETY_ DEPT, .. Digitally signed APPROVED--. FOR CONSTRUCTION ry1r by Matthew W. 1r'i�.ii ATE Br Bailey P.E. -----'Date: 2015.09.05 10:51:56 -06'00' 1\LV LLV.OJ - RCMUCIR,Idl Lyaa %. IGY1dl1UIl NEC 220.83(B) "Existing Dwelling Unit.... to determine if the existing service ... is of sufficient capacity ... The following percentages shall be used for existing ... loads ... First 8 kVA of load at 100%, Remainder of load at 40% NEC 220.83(6)(1) General lighting and general -use receptacles at ... 3 volt-amperes/ft2 as determined by 220.12. Floor Area (3VA/sq ft) I Ft VA 2364 7092 NEC 220.83(B)(2) 1500 VA for each 2 -wire, 20 -ampere small -appliance branch circuit and each laundry branch circuit covered in 210.11(C)(1) and (C)(2). NEC 220.83(6)(3) All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit fandl water heaters" Qty I VA Small Appliance Circuits 2 3000 Laundry Circuits 1 1500 Bathroom Circuits 1 1500 NEC 220.83(6)(3) All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit fandl water heaters" Total General Load (non -A/C load) 34212 VA First 8 kVA of load at 100% 8000 I General Calculated Load (non -A/C load) 18484 VA NEC 220.83(8) The larger connected load of air-conditioning or space -heating, but not both, shall be used ... [at] 100 Percent of Load Total Load Breakerl VA Oven 40 7680 Dishwasher/Garbage Disposal 20 3840 Other 50 9600 Total General Load (non -A/C load) 34212 VA First 8 kVA of load at 100% 8000 I General Calculated Load (non -A/C load) 18484 VA NEC 220.83(8) The larger connected load of air-conditioning or space -heating, but not both, shall be used ... [at] 100 Percent of Load Total Load Max Heating and Air -Conditioning load 9000 VA Sum of General Calculated Load 27484 VA & Heating and A/C Load 114.52 A CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARGTY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE THE WRITTEN PERMSSIONCITY EOFISOLARGTY INC Breakerl VA Sum of A/C Equipment50 Sum of Electric Furnaces 0 9000 0 Max Heating and Air -Conditioning load 9000 VA Sum of General Calculated Load 27484 VA & Heating and A/C Load 114.52 A CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARGTY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE THE WRITTEN PERMSSIONCITY EOFISOLARGTY INC JOB NUMBER JB -9224171 00 PREMISE OWNER: DESCRIPTION: WISEMAN, TERRY ESPLANADE WISEMAN RESIDENCE 79718 PARKWAYES LAN 14.575 KW PV ARRAY LA QUINTA CA 92253 r C PAGE NAME 760 710-7996 ELECTRICAL LOAD CALCULATIONS DESIGN: Joyce Lin y " \\�rpSolarCit . � ..,c �/ �, MOUNTING SYSTEM: ZEP Mighty Hook MODULES (55) KYOCERA # KU2656ZPA 3055 aearneN way San Mateo, CA 94402 (e6ej (650) 638-1028 38 (I28 F:()50638-10 9 SHEET: REY. DATE: PV 10 a 8 13 2015 / / INVERTER. Multiple Inverters ' ° e - , ' r • - Y ' �� - � r � ` .. ' T •. ' • . � .. rt ^ `• • Yom, Y ... +. r � • 9 ' i - , • . -1/ Label Location:,. 7M WARNING: PHOTOVOLTAIC POWER SOURCE Per •.- CRC R331.2 - 1 Location. PHOTOVOLTMLDISCONNCc .•• -Label MAXIMUM POWERpj® POINT CURRENT Im Per Code MAXIMUM POWER -=V CEC 690 POINT VOLTAGE (Vmp) MAXIMUM SYSTEMV VOLTAGE (Voc)® SHORT-CIRCUIT CURRENT (Isc)®A Label Location: ' NEILMECTRICAL Per ..-SHOCK HAZARD DO.NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED ~LL SOLAR MODULES ARE WARNING: ELECTRIC SHOCK . EXPOSED TO SUNLIGHT HAZARD. DO NOT TOUCH ' • 690.17 TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label ion:DE-ENERGIZE BOTH SOURCE WARNINGAND MAIN BREAKER. PV POWER SOURCE Per Code: MAXIMUM AC ELECTRIC SHOCK HAZARD •. OPERATING CURRENT A IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED MAXIMUM AC ® V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED PHOTOVOLTAIC AC CAUTION - S PHOTOVOLTAIC SYSTEM " ••• • Iv,- t•. r 7•• - {.: ♦ . - r � �:�:'`� ss`1. - •. - ALM �•. , � \1 ♦. ,,, ;`- (AC): AC Disconnect' �� A (C); Conduit .C. CEC 690 142 ' _ - _ 4 ; (CB): Combiner Box �. ' k - r s a.. A J (D): Distribution..Panel + (DC): DC Disconnect r' tenor Run Conduit ,. Label Location: - Label Location R ..� ; (IC). In ,+ INV Inverter WitFi lMAXIMUM AC ntegi` ted DC Disconnect. AC POI (INV): ( ) (POI) ' • (POI) �. (LC): Load Center •' Per Code: 0 . POWER . Per. Code:? ° .F .. , <;; �� ' . CEC 690.54 SECONDSOURCECEC 705:12.D.7 (M): Utility Meter MAXIMUM AC J .3 4 r li OPERATING VOLTAGEPHOTOVOLTAIC .'(POI): Point of In terconnection� CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR • �e�Hr� 3055 Clearview Way . THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED' ��: Y , � - `' San Mateo, CA 94402 , IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Sgt - R ,' r ������� 7:(650)638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (888)SOL-CITY (765-2489) www.solardty.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. - Sow io ' ' Label Location: .Label Location: (AC) (DC)(INV)(CB)'SYSTEM FNNECTFOR Per Code:Y OPERATION ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF CEC 690.35(F) PHOTOVOLTAIC TO BE USED.WHEN _ -•. . . INVERTER ISMAY BE ENERGIZED UNGROUNDED Label Location. ` ��` ?. F • .� ..; A RNING Per Code: • -' CEC 690.17ON ' rUCH TERMINALS BOTH LINE AND -• BE ENERGIZED- .. r . - r z7 /,tit. A *V. ° �, r ; 1 ,` k .- . .-, . • - - .. ...•. '. _. : c • • YS �• ` w Label Location: (POI), Per` Code: TER OUNNECTITPUT , CEC,705.12.D.7 F7 RELOCATE VERCURRENT WEVICE - -, , - r � - � i g .�' "' Label Location: �• • : _° ` ' FLTAIC POINT OF (POI) e7,z ~LL SOLAR MODULES ARE WARNING: ELECTRIC SHOCK . EXPOSED TO SUNLIGHT HAZARD. DO NOT TOUCH ' • 690.17 TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label ion:DE-ENERGIZE BOTH SOURCE WARNINGAND MAIN BREAKER. PV POWER SOURCE Per Code: MAXIMUM AC ELECTRIC SHOCK HAZARD •. OPERATING CURRENT A IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED MAXIMUM AC ® V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED PHOTOVOLTAIC AC CAUTION - S PHOTOVOLTAIC SYSTEM " ••• • Iv,- t•. r 7•• - {.: ♦ . - r � �:�:'`� ss`1. - •. - ALM �•. , � \1 ♦. ,,, ;`- (AC): AC Disconnect' �� A (C); Conduit .C. CEC 690 142 ' _ - _ 4 ; (CB): Combiner Box �. ' k - r s a.. A J (D): Distribution..Panel + (DC): DC Disconnect r' tenor Run Conduit ,. Label Location: - Label Location R ..� ; (IC). In ,+ INV Inverter WitFi lMAXIMUM AC ntegi` ted DC Disconnect. AC POI (INV): ( ) (POI) ' • (POI) �. (LC): Load Center •' Per Code: 0 . POWER . Per. Code:? ° .F .. , <;; �� ' . CEC 690.54 SECONDSOURCECEC 705:12.D.7 (M): Utility Meter MAXIMUM AC J .3 4 r li OPERATING VOLTAGEPHOTOVOLTAIC .'(POI): Point of In terconnection� CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR • �e�Hr� 3055 Clearview Way . THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED' ��: Y , � - `' San Mateo, CA 94402 , IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Sgt - R ,' r ������� 7:(650)638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (888)SOL-CITY (765-2489) www.solardty.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. - Sow io ' ' i i AU 11►�? Designed for residential and small I The wide input voltage range Highlights: commercial PV installations, this makes the inverter suitable to low -Single phase and split phase output inverter fills a specific niche in the power -installations with reduced grid connection. ABB product line to cater for those string size. - Wide input range for increased installations producing between The transformerless operation offers , ._ —stringing flexibility. 5kW and 20kW. high performance efficiencies of up to - The high speed and precise MPPT 97.1%• algorithm offers real'time power This inverter includes dual input Free remote monitoring capability : tracking and improved'energy section to process two strings with available with every installation. This harvesting. independent MPPT. enables homeowners to view their - Outdoor NEMA 4X rated enclosure The high speed and precise MPPT energy production and offers installers for unrestricted use under any algorithm offers real-time power a proactive and economic way of ► environmental conditions: - tracking and energy harvesting. maintaining and troubleshooting the - Integrated DC disconnect switch Flat efficiency curves ensure high system. in compliance with international efficiency at all output levels ensuring - Standards (-S Version). consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. Power and productivity for a better world'" oil 0 PUMP Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types Type code PVI-5000-OUTD-US Power tactor .......................................................... Total harmonic d.is.tortion ........................................................ Contributory fault current' Maximum Ambient air operating temperature range 13°F to +140°F (-25°C to +60°C) +176 .......................................................................................................................................... i........................................................................................... Ambient air storage temperature. range 40°F to °F (-40°C.to Relative humidity 0 1.00% RH condensing ....... ......... ......... Acoustic noise emission level < 50 db (A) ®1 m .................................................................................................................................................................................................... Maximum operating altitulde without deraliny 6560 ft (2000 m) .............. 2. Inverter can apply that much current - Breaker will open 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD x 208V PVI-6000-OUTD-US Cfr1�l•17G1C=iGP. w - ''"SO�afCtty I ZepSolar . t Next -Level PV Mounting Technology ,' "'^$olafCity I ZepSolar i _ Nez_t-Level PV Mounting Technology -Components ZS Span for concrete tile roofs - - - - _ .1z 3x 4x Spanner, Bar Groove; .Cam fm4; '" ' + - _ i ~ t Part Nos. - i 1 .. y aoo 1400 . 580-1399 - 3x ' t �,• ! 850-1398 -1x _. Spamcer8ar� .•,. ., `� J • .. - `~ - _ �~ , SpamrefL9amJf.:l r � ? , . •. .. � r„ J I „ - - - _ r •..ice . + - i A,ray Kit • ;« , ° Splice i t Spanner Clamp Part No. 850-1401 Part No. 850-1194 - T Listed to UL 2703' ; Listed to UL 2703 , l - j Ai�i.. _. � f?ortier Cap, ,#_ Imaitock AdJustatila Mighty Hoofs, - +- � - . "014 PA Description • / PV mounting solution for concrete tile roofs -- ., Works with all Zep Compatible Modules - _ • °MPp t. • ' Auto bonding UL -listed hardware creates structural and electrical bond r - " Zep System has a,UL,1703 Class "A" Fire Rating when installed using modules from r. a a,' ,•.,' - " "+ any manufacturer certified as "Type 1" or "Type 2°• tt - Mighty Hook V2, HDG Interlock' r. } Cam Foot, r UL LISTED Specifications > PNo. 850-1461 PNo. 850-1388 • t PartNo. 850-1413 _ • ~r - _ rr « art �:.�' art - - _ „ * " , • t' w' Listed to UL 2703 Y Listed to UL 2703 Listed to UL 2703 - - _ Designed for pitch roofs E = « r } Installs in portrait and landscape orientations , . •r ' - Zep System supports module wind uplift and snow load pressures to 50 psf per UL -1703 - ETh r' 1 Wind tunnel report to ASCE 7-05 and 7-10 standards' .' Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 - ` - • _ 4, ' ' . Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" - ' '' '• r ' Zep wire management products listed to UL 1565 for wire positioning devices *, ' •, ° �l 1 _, - _ • Attachment method UL listed to UL 2582 for Wind Driven Rain { ' ..: r_ j '• ,` - - " ' .+. Ground Zep, Array Skirt, Grip, End Caps DC Wire Clip Part No 8501172 Part Nos 850-0113, 850-1421, Part No 850-1448 r ' ' * ` _ • ETL listed to UL 467 850-1460, 850-1467 Listed to UL 1565 _ } zepsolar.com zepsolar.com- " Listed to UL 1565 y - ! This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solars products constitutes the sole specifications referred to in the product warranty. The customer is solely ' each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely +. • ' responsible for verifying the suitability of ZepSolars products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.wm. • • - - _ responsible for verifying the suitability of ZepSolaes products for each use. Specifications are subject to change without notice. Patents and Apps: zspals,com. , Document # 800-1730-001 Rev A :,,, _ - ' Dale last exported: April 20, 2015 2:14 PM , - - Document # 800-1730-001 Rev A - _ Date last exported: April 20, 2015 2:14 PM ' A �1 IU K90[ERa KU -60 l 000V Z Series ', KU265-6ZPA CUTTING EDGE TECHNOLOGY As a pioneer with four decades of experience in the development of photovoltaic systems, Kyocera drives the market as a leading provider of PV products. We demonstrate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard in the innovation of best -in -class solar energy equipment. QUALITY BUILT IN • UV -stabilized, anodized aluminum frame in black • Supported by major mounting structure manufacturers • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire works with transformerless inverters • Amphenol H4-UTX locking plug-in connectors provide safe, quick connections PROVEN RELIABILITY • Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average output of any crystalline module • First module manufacturer in the world to pass long- term sequential testing performed by TOV Rheinland • Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM Research's 2014 PV Module Reliability Scorecard CERTIFICATIONS • UL1703 Certified and Registered, UL Module Fire Performance: Type 2, CEC • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 Q��MPAT�6 Y C @ us �pC'OMPPO ELECTRICAL SPECIFICATIONS Standard Test Conditions (STC) STC=1000 W/M' irradiance, 25'C module temperature, AM ].5 spectrum" KU265-6ZPA 265 W 8.55 A 9.26 A Nominal Operating Cell Temperature Conditions (NOCT) NOCT=800 W/M' irradiance, 20'C ambient tenTperature, AM 1.5 spectrum 45 c V.. 27.9 I 6.85 Weight 45.2lbs (20.5kg) Ven 35.1 la 7.49 PTC 238.1 V KU -60 1000V Series MODULE CHARACTERISTICS Cells per module: 60 (6 x 10) Dimensions.. lengttVwidth/height 65.43ini38.98ini 1.57in (1662mmi990mmi40mm) Weight 45.2lbs (20.5kg) PACKAGING SPECIFICATIONS Modules per pallet 20 Pallets per 53' container. 36 Pallet box dimensions: length/width/height 66ini40ini43in (1675mmi 1005mml 1 055mm) Pallet box weight 1015lbs (460kg) POTTED JUNCTION BOXOP65) ---� CABLE W/ 95 e Ll t_1 �+� ALABEL V A ui Temperature Coefficients P 0.45 %/°C V1 - -0.48 %/°C ----- ImP — ------ 0.02 -- — %/°C V. -0.36 %i°C IK 0.06 %J°C Operating Temp -40 to +90 °C System Design Series Fuse Rating 15 A Maximum DC System Voltage (UL) 1000V Hailstone Impact in (25mm) @ 51 mp (23m/s) 'Subject to simulator measurement uncertainty of +l. 3%. KYOCERA reserves the right to modify these specifications without notice. WARNING, Read the im rucuon manual in its entirety prior to handling, installing 8 operat- mg Kyocera Solar modules. 040215 1_� lkly —dine H.I. Slotted Nountin¢ H.I. 0.I6- t<r'O 0.35-80.47- (9—lb.) FRAME CROSS SECTION DIAGRAM r, I. ]e-I35vd LONG/MT SIDE OUR VALUED PARTNER ��•,. r - _. • -,t F J • � 'r+ y .. ' - it l .' ••�' .. • , V �. ' ,. IT : a t - Switching Devices .• 8.1 r ; Safety Switches, c , w 720/240 Vac General -Duty, Fusible, Single -Throw, continued ��� ; 4 1 r # ? r OG321NR6 - _ y •x '-" r `F i' r • - +- Maximum Horsepower Ratings (D � - -©y i -r E �- t - - - NEMA1 NEMA311{ Potyenng6Usne3sWo/la'Ivfde JJJJJJ .,�f r Ampere .Fuse Type Single -Phase AC _ , Three -Phase AC _ DC Enclosure Indoor Enclosure Rainproof ') �„ >F''-4 1,W-2e.,;,4tr •'.� ' •,'*~ r' �:.,'- r *' t ' - System Rating Provision _ 12UV 240V 240V 250V' Catalog Numhei Catalog Number - �. _ _ _ _ _ -__ •'-+- _ _ _ _ - - - _ x, !+� ° • : • _, k Cartridge Type —Three•Pole, Three -Wire (Three Blades, Three Fuses) -240 Vac ' v � �' ' S � �, �x , 30A., �-.4? .z �k�.i• 'C— — — — —o ;. 2a f� ,r ',. - - 160 — ,: _. _ — — — t i - f <<. a i - • - r _ - v ` r .• - 200 — — — — - I^ 'iD _ • t _ • 400 - , H — — 50-125 — OG325FGK DG325FRKO0 } �' _ �, - nines a ty Safety Sw i 600 H ., — 75-200 - :OG326FGK�0 DG326FRK00 arra or..'. ase uridad:.96"Vicio li` �ero _{.._-.. _ - ,.. �.,:,.. •; 1;z r r' _ - _ - _ °•' • � - �+ Cartridge Type-FourWire (Three Blades, Three Fuses, S/N)-120/240 Vac. .� ` . � �." •' � - - � z {° 30. =H . .,1-1/2-3 3-7-1/2 t — 'DG321NG6. DG3ZINRB _�• - - �-}' S;:• Cant o a-� 2 2 D 1 �t! 'r• . _ 60.: H - 3-10 7-1/2-15 . — DG322NGB OG322NR6,.7,, • yk _�sr, s -._ S..t S '` r• Tf S®ne3 n usble.• in fueibl:® 6 a H r -1MM IN UA.A. - _ -. — 7.12-15 - 15-30 _ • .. ' DG323NG8 OG323Nfl6 �I e��A7'r -�'{S. 'IIECNOENE.U,Aa,. •�' 8 8 4S0'Y l• 7 .100 H 200 H — is 25=60 _— UG324NGK DG324NRK - - R .Rain ro°o , .,_ , MA) Tipo R. pru, de U sV i; • � 400 H - — 50-125 — OG325NCK DG325NRK � 600 ` H — — 75-200 DG326NGK DG326NRK it OG322URB - 120/240 Vac General -Duty, Non -fusible, Single -Throw . - � • , •.�� + us,�.',' Maximum Horsepower flatings - - t - NEMA 1 NEMA 3R _ - .:..:srrti..St- _ Ampere Single -Phase AC Three -Phase AC DC Enclosure Indoor Enclosure Rainproof - - - System Rating 120V • 240V 240V 750V Catalog Number Catalog Number r Two -Pole, Two -Wire (Two Blades) -240 Vac - b b 30 2 3 — — OG221UGS0 OG221URB0 + 60 3 10 — - - — DG2220GBf•t DGZ22URB<•t k . r ; 100 — is — — DGZ23UGBO ' DG223URB 0. .. 200 ' Three -Pole, Three -Wire (Three Blades) -240 Vac -it bbd 30 2 3 7-1/2 — OG321UGB0 DG321URB0 F • 60 3 - 10 15 . — OG322UGB0 OG322UR80 _ - 100 - — r •- 15 30 — OG323UG80 OG323URB0 y _ 200 _ — 15 1 60 OG3241100 OG324URK0 1 - •� - , - _ _ 1 • 400 — — 125 — OG325UGK0• - " OG32SURK0 s 600. — — 200 — DG326UGK0 DG326URK0 • - Notes • 0 Maximum he ratings apply only when dual element time delay fuses are used. ' • r ' , • ` 0 Use four -wire catalog numbers below. _ • _ - - - - - - .0 Solid neutral bars are not included. Order separately from table on Page 15.- a .. @r WARNING! Switch is not approved for service entrance unless aneutrat kit is installed. � � - s � • - � � - " W Use three -wire catalog numbers below. - - , • - - .. ' • _ 0 Drilled to accept field installed neutral kits. - .< -• - - 7 . t r - All general -duty safety switches are individually packaged. � � .. - - - ` Accessories are, limited in scope on general -duty safety switches. See Page 15 for availability. In addition, clear line shields are available as an accessory .. - - • • N _ •. - � v _- on 700 600A yanaral J�lr ,,,,a„I w. O�t�l�y Hwnln.ia. L86A=78.7}35.1 i, vOuA= ro-ouw-a, 4uuA a ru-eue4-6. • -' - • • ,� . � , • e - • • •• ) 1 un Volume 2—Commercial Distribution CA08100003E—Febmary 2011 www.eatoacom 27. - - • ; , - r • - > / DI .281 [5.5 KNOCKOUT QUANTITY 1 4 Sa .a 0 (v a k o p °irev°"e/iaNa � 4 CENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 0 NTITY 2 QUANTITY 4 N 3 MOUNTING HOLES N O m B NGENTIAL KNOCKOUTS FOR N IANTITY 1 O 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN �IN BRACKETS. 0 .281 [5.5 KNOCKOUT QUANTITY 1 4 Sa .a 0 (v a k o p °irev°"e/iaNa � 4 CENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR , 3/4 CONDUIT 1/2, 3/4 CONDUIT NTITY 2 QUANTITY 4 27 '[6.8) DIA. 3 MOUNTING HOLES N O m B NGENTIAL KNOCKOUTS FOR '2, 3/4, 1 CONDUIT IANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN �IN BRACKETS. 2. WIRE RANGE OF LUGS IS AS FOLLOWS LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM NEUTRAL #4-#14 COPPER OR ALUMINUM A mr or vlal oowmaiori WARREN gPE 8 19 98 CUTLER -HAMMER rs o �noc["bPRTSBURGH PA. �� Flt�i12- R. PROHASKA 8/19/98 DIMENSION SHEET Poa� fOR MKKX rt 6 NFMSxE0. .soa an 30 AMP TYPE. 3R GENERAL DUTY 95-1 c S.DNG 1WBq OSi¢ VNlL! xaJ Sawt SS74DM 1-2 5-1445 1 OF 1 2 1 ZepSolar Datasheet: ZS Tile ZS Tile - for tile roofs Datasheet: ZS Tile Components Interlock ;? The Interlock provides north -south and east -west structural and ground bond connections creating a structurally contiguous hyper -bonded array. Interlock UL listed to UL 2703 and ETL listed to UL 1703. - Leveling Foot(31.amm1 fao.7mm] �I—f• 1.25in 1.21in m] (39.dmm] - 2.Y5in 1 Sst>� (91.2mm1 1 3.20in I (101.6mm) l— n:ooin ._ The Leveling Foot provides a means of attachment between the PV array and the mounting surface or flashed attachment - apparatus and allows for easy array height adjustment (1.25' throw). Array Skirt J nu;aa The Array skirt facilitates easy front -row installation while providing a clean look at the front of the PV array. Ground Zep y� Lari The Ground Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required for every 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703. Universal Box Bracket AC/DC Cable Clip Replacement Tile The Universal Box Bracket allows rapid attachment of Clips into. Zep Groove for ultra -fast and easy The Replacement Tile provides a means offlashed electrical boxes to the module frame. management of PV wiring and micro -inverter cables. attachment for ZS Tile installations. Array Skirt Cap Set Tools The Array Skirt Cap Set provides an aesthetic cover for Zep Toot 4 functions, I tool; Flat Tool: For inter -module - the exposed end of the Array Skirt. Made of anodized removal. aluminum, each set comes with two Skirt Caps. - This document does not create am apress wannty by yep Solar of about its products of services yep Solais sale wamnty is comalned in the written product mranty, lm each Visit repsolaccom far more information about aur products andcompany. moduu.TheemkiN documentation shipped with2epSolat ipfoductsmmtituinitm wlespeci iwtionsrelmed to in theproducteemanty.Thewstamef ksalely resimadi le lar redhifry the sulubiliryol lasSohn s"educts im each use. Specifications are who to dmngewithom amti[0rapytilld m 2010-2011 yep Solar. Inc. IIS Patent 12,59LV.. U.S. , Patem8.109.D4kU19N1Pama,;Pmd4 Last Update:Febrany75,20133:IIPM Page 2 0/ 2 t r ZS Tile'" offers the fastest and least expensive way to install PV Zep Compatible"' arrays on tile roofs. It's designed to interoperate with a growing list of Zep Compatible PV modules that incorporate the patented Zep Groove ZS Tile mounting hardware is 9 designed for use with Zep frame specification. Utilizing quarter -turn, rock -in, and drop-in con- Compatible `"Pvmodules from nections, ZS tile eliminates the need for rails and separate grounding leading PV module Manufacturers, hardware while offering a superior aesthetic approach. Visit zepsolar.com for a current list of Zep Compatible`" PV modules. Key System Benefits Key Technical Features Our Other Product Families Dramatically reduces installation Low system weight ZS Aero time for low -slope & flat roofs Easily enables additional support Camp - ZS Camp - Eliminated mounting rails and clip at array edges for high wind , for composition shingle roofs hardware applications ZS Seam' Eliminates separate grounding Interlock ETL listed to UL 1703 as . for standing seam metal roofs a hardware ground bond means . ZS Span- ! for rail -based applications Rapid, top -accessible precision array leveling Ground Zep UL and ETL listed to UL t . ZS Trap' 467 as grounding and bonding device for trapezoidal metal roofs Ultra -reliable hyper -banded ZS Wave grounding. Interlock, Leveling Foot, Ground matrix neroc, eveng oo, anroun 9 9 , for corrugated roofs ` Zep listed to UL 2703 as PV bonding Ultra-low parts count device Enhanced aesthetics T LISTED MPN Page 1 of 2 Datasheet: ZS Tile Components Interlock ;? The Interlock provides north -south and east -west structural and ground bond connections creating a structurally contiguous hyper -bonded array. Interlock UL listed to UL 2703 and ETL listed to UL 1703. - Leveling Foot(31.amm1 fao.7mm] �I—f• 1.25in 1.21in m] (39.dmm] - 2.Y5in 1 Sst>� (91.2mm1 1 3.20in I (101.6mm) l— n:ooin ._ The Leveling Foot provides a means of attachment between the PV array and the mounting surface or flashed attachment - apparatus and allows for easy array height adjustment (1.25' throw). Array Skirt J nu;aa The Array skirt facilitates easy front -row installation while providing a clean look at the front of the PV array. Ground Zep y� Lari The Ground Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required for every 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703. Universal Box Bracket AC/DC Cable Clip Replacement Tile The Universal Box Bracket allows rapid attachment of Clips into. Zep Groove for ultra -fast and easy The Replacement Tile provides a means offlashed electrical boxes to the module frame. management of PV wiring and micro -inverter cables. attachment for ZS Tile installations. Array Skirt Cap Set Tools The Array Skirt Cap Set provides an aesthetic cover for Zep Toot 4 functions, I tool; Flat Tool: For inter -module - the exposed end of the Array Skirt. Made of anodized removal. aluminum, each set comes with two Skirt Caps. - This document does not create am apress wannty by yep Solar of about its products of services yep Solais sale wamnty is comalned in the written product mranty, lm each Visit repsolaccom far more information about aur products andcompany. moduu.TheemkiN documentation shipped with2epSolat ipfoductsmmtituinitm wlespeci iwtionsrelmed to in theproducteemanty.Thewstamef ksalely resimadi le lar redhifry the sulubiliryol lasSohn s"educts im each use. Specifications are who to dmngewithom amti[0rapytilld m 2010-2011 yep Solar. Inc. IIS Patent 12,59LV.. U.S. , Patem8.109.D4kU19N1Pama,;Pmd4 Last Update:Febrany75,20133:IIPM Page 2 0/ 2