Loading...
04-4356 (SFD)O f!'6v BUILDING & SAFETY DEPARTMENT K+� P.O. Box 1504 (760),7.77-7012 piT4'�`' - 78=495aCALLE TAMPICO - FAX (760) 777.701 1 1,=� L,Aa`QUINTA,• CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 4 16 704 BUILDING PERMIT GITV OF gA QUiW 5A EO . App4-rcat-ron'Nu er . . . . [04=00-0;0435 Date 6/09/04 Property Address 7-97-8-2—PARKWAY ESPLANADE N APN: .609-380-998-69. -293.232- Application description DWELLING`.- SINGLE FAMILY DETACHED Property Zoning . . . . . . LOW DENSITY RESIDENTIAL Application valuation . . . . 126211 Owner ----------------------- LENNAR HOMES OF CALIFORNIA :78401 HIGHWAY 111, STE C LA QUINTA, CA - LA QUINTA CA 9.2.253 Contractor LENNAR HOMES.OF CALIFORNIA .INC 78401 HIGHWAY 111, SUITE C' LA, QUINTA CA 92253 WCC: OLD REPUBLIC IN' WC: MWC10877600 11/01/04 CSLB: 728102 09/30/04 i CCC: B ------------=------------- Structure Information. ------------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type DWELLG/LODGING/LONG <=10' Flood Zone . . . . . . ... NON -AO FLOOD ZONE Other struct.info . . . . CODE EDITION 2001 CRC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE" ;SQ FTG PATIO SQ.FTG 53.00 NUMBER OF UNITS 1.00 FIRST FLOOR -SQ FTG 2041.00 Permit. BUILDING PERMIT Additional desc-. Permit Fee 734.00 Plan,Check Fee 119.28 Issue Date . . . . Valuation 126211 Qty Unit -Charge Per' Extension BASE 'FEE 639.50 27.00 3.5000 THOU BLDG.100,001-500,000.;.. 94.50 Permit . . . . . . MECHANICAL Additional.desc Permit .Fee 46.00 Plan Check Fee 2.88 Issue Date Valuation 0 Qty Unit Charge. Per Extension P.O. BOX 1504 78-495 CALLE-rAMPlt.O LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number:. Applicant: Applicant's Mailing Address: VOICE (760) 7'7.701. FAX (760) 777.701 INSPECTIONS (760) 777.71 5: Date: (o- /�-o Y Pch&o�Eng!mh, 11 �Do or Enginet;r's A�dress: Lic. No.: BUILDING PERMIT DECLARATIONS I hereby affirm under penalty of LICENSED CONTRACTOR'S DECLARATION Y Perjury that I am licensed r provisions of Chapter 9 (commencing with Section 7000) of Division 3 of Mie Business and Professionals Code, and r Linde is al full force and at I a /License Class_ License No. 1 hereby affirm under Halt of OWNER -BUILDER DECLARATION penalty Perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct. alter, improve, demolish, or repair any structure, prior to its issuance. also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 311f the Business and Professions Code) en that f or she is exempt therefrom and the basis for the alleged exemption. Any violation Of Section 7031.5 by any applicant for a permit subjects, the applicant to a civil penalty of not more than five hundred dollars (5500).): U I, as owner of the property or my employees with wages as their sole compensation, will do the worts, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the the work building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon• and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.), U I am exempt under Sec. . BA P.C. for this reason Date Owner I hereby affirm under Penaltyof WORKERS' COMPENSATION DECLARATION Perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation• as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is su o e ompensation i nce Carrie�11/Cartier Policy NumberMu ��y thathn the pertormance of the work for whicn ishall not em to an compensation laws of California, and agree that, if I should become subject to the workers'any person in any manner so as to become subject to the workers' r e forthwith comply with those provisions. compensation provisions of Section 3700 of the Labor Code, 1 shall Date tl Q plicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. I hereby affirm under penalty of perjury that there is a construction IendNSTRUCTION LENDING AGENCY 9 agency for the performance of the work for which this Lenders Name permit is issued (Sec. 3097, Civ. C.). Lender's Address IMPORTANT APPLICANT ACKNOWLEDGEMENT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application I. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to an issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quints, its officers, agents and employees y �� gees for any act or omission related to the work being performed under or following issuance of this permit. 2• Any Permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of cosh permit or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct I agree to comply with all city and county ordinances and construction, and hereby authorize representatives of this county to enter upon the above-mentioned Property for inspection purposes. state laws relating to building /Date J -O nature Si 9 (Applicant or Agent): _ 7�vS `�H._wzr.�.g�'t .•:;r `. s[fr� •i �' _i'ii: Page 2 Application Number . . . 04-00004356 Date 6/09/04 Qty Unit Charge Per Extension BASE -FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH"B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA MECH VENT FAN 6.50 1.00 6:5000 EA MECH-EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit ELEC-NEW RESIDENTIAL Additional desc ► Permit Fee . . . . 95.38 Plan Check Fee 5.96 Issue Date Valuation 0 Qty Unit Charge Per Extension - BASE FEE 15.00 2041.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 71.44 447.00 0200 ELEC GARAGE OR NON-RESIDENTIAL 8.94 Permit . . . . . . "PLUMBING Additional desc Permit Fee . . . . 164.25 Plan Check'Fee 10.2'7 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 16.00 6.0000 EA PLB FIXTURE 96.00 1.00 15.0000 EA PLB BUILDING -SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1:00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 .15.0000 EA PLB GAS METER 15.00 Permit . . . . . . GRADING PERMIT Additional,desc Permit Fee . . . . 15.00Plan Check Fee.. .00 Issue Date . . , tr Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00. ------------------- Y Special Notes ------------------ and Comments ---------------------------- ----------- SFD _ LOT 69. PLAN,1Y. PERMIT DOES NOT Page 3 Application Number . . . .. 04-00004356 Date 6/09/04 Special Notes and Comments INCLUDE BLOCK WALL, POOL, SPA OR DRIVEWAY. APPROACH. 75% PLAN CHECK FEE REDUCTION APPLIED FOR MULTIPLE I`SSUANCE OF SAME.PLAN TYPE. Other Fees . . . . . . . ART IN PUBLIC PLACES -RES 00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 11.93 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE - 00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5,.00 DIF PARKS/REC`- RES 502.00 STRONG MOTION (SMI) - RES 12.62 DIF STREET MAINT FAC -.RES 15.00 DIF TRANSPORTATION - RES .1098.00 ' Fee summary Charged Paid Creditc-d Due Permit Fee Total 1054.63 .00 .00 1054.63 Plan Check Total 138.39 .00 .00 138.39 Other Fee Total 2429.55 .00 ..00 2429.55 Grand Total 3622.57 .00 ..00 3622.57 ENERGY CAD E C same PO. Box 621 Rancho Mirage, CA 92270 Email: DESNRG (cD OL.COM Ph/Fox(760)564-2044 Cell: (7601250-1852 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R TAPESTRY @ ESPLANADE PH 9 DATE TESTED. 02-01-05 Project Title Date PARKWAY ESPLANADE NORTH LA QUINTA CA LENNAR HOMES roLec Address 909-275-0204 Builder Name TONY PASCANITE PLAN 1Y 1 UNIT Builder Contact Telephone Plan Number RICHARD KROWN 760-250-1852 GROUP 5 HERS Rate Telephone Sample Group Number #CCNRK613292 02-02-05 LOT 69-9 1 OF 1 Certifying Signature Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider: CHEERS Street Address: P.O. BOX 621 Copies to: Builder, HERS Provider City/State/Zip: RANCHO MIRAGE, CA. 92270 HERS RATER COMPLIANCE STATEMENT The house was: ® Tested ❑ Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ® The installer has provided a copy of CF -6R (Installation Certificate. ® Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ® Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ® MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Duct Pressurization Test Results (CFM @ 25 Pa) Test Leakage Flow in CFM If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = Check Box for Pass or Fail (Pass=6% or less) ® THERMOSTATIC EXPANSION VALVE (TXV) ® Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection Measured values 109 2000 C AC Pass Fail W ,i C T (D 0 N O Lo r Certificateof Insulation Your home has been insulated with Certain Teed Fiberglass insulation products, which are designed for today's safety standards and tomorrotiWs energy requirements. Fiberglass is inorganic and therefore permanently noncombust.,ble, so it does not have to be treated with fire -retardant chemicals that will likely lose their effectiveness over time. It has not been treated with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it settle over time as may other insulation materials. This also certifies that insulation have been professionally installed in this home to provide the following thermal performance. Job Name. Lennar Homes, Inc. Tract: 29323 Plan# 1Y Phase: 9 Lot No: 69 Job Address: SFR - 79-782 Parkway Esplanade North, La Quanta, CA Ceiling Area: R-38 blown -in fiberglass insulation Garage Ceiling: Non -Access: With Living Above & Sloping Areas Exterior Walls R-13 batt insulation Overhangs: Access Attic: With Living Above Between Floors: Interior Walls: Subcontractor ...0 J Insulation, Inc, 72-227 Adelaid St, Thousand Palms, CA 92276 Signed: Mike Dickerson, General Manager - Palm Springs Branch R•means resistance to heat low. The higher the R -value, the greater the insulating power. Ask your builder for the fact sheet o -n R -values. Keep this certificate with your other valued papers. If you ever sell this home, this certificate should be passed on to the buyer. `.: i w s C:ITTOF LA QUINTA. BUILDING "& SAFETY DEPARTMENT j FM OF T` 777-7012 INSRECTION REQUEST LINE { 777-7153 Owner LENNARRO.MES OF CALIFORNIA ` ContractorLENNAR HOMES OF CALIFORNIA Permit Number--,- POST umber POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES I JOB ADDRESS 79-782 PARKWAY ESPLANADE N SFD — LOT 69 PLAN 1Y. PERMIT DOES NOT i INCLUDE BLOCK WALLS,. POOL, SPA OR I DRIVEWAY APPROACH. TYPE OF INSPECTION DATE INSP. TEMPORARY POWER SETBACKS U/G PLUMBING /WASTE U/G ELECTRICAL / GROUNDING FOOTINGS / STEEL CONCRETE.SLAB Y,107AF7' 4.4,1 DO NOT POUR CONCRETE UNTIL ABOVE: SI NE ROOF NAIL / PRE -ROOF b OKAY TO WRAP / a . FRAMING COMBINATION ROUGH ELECTRIC / d ROUGH PLUMBING ROUGH MECHANICAL INSULATION COVER NO WORK UNTIL ABOVE SIGNED INTERIOR GYP. BD. DRYWALL /�1-d'7 0 EXTERIOR LATH / GAS TEST SEPTIC ABANDONMENT SEWER CONNECTION y SEPTIC / GREASE INTERCEPTOR MASONRY INSPECTIONS FOOTINGS / STEEL . BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS U/G PLUMBING U/G GAS U/G ELECTRICAL PRE -PLASTER ALARMS / BARRIERS FINAL INSPECTIONS TEMP. USE OF PERMANENT POWER )../.,2e, 105-. ELECTRICAL PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT 1 2 - - FINAL'/ JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING