04-4358 (SFD)r V. ry 0 � s BUILDING & SAFETY DEPARTMENT P.O. Box 1504 (760).777-7012 OFT '�¢ 1'915 CALLS TAMPICO FAX (760) 777-7011 r p a VU NTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 77,7-7153 16 2Q�� BUILDING PERMIT I.p, trat3t�Fa AppliYc4at�,o>a=�Ntz er . . . .�04-0000435-8� - Date 6/09/04 F�raper y Address . . . . . . 79814 PARKWAY ESPLANADE N APN: .609-380-998-71 -293232- Application description . . . DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . . . LOW-DENSITY RESIDENTIAL Application valuation, . . . . 128508 Owner Contractor. LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC .78401 HIGHWAY 111, STE G 78401 HIGHWAY 111, SUITE C LA QUINTA, CA. LA QUINTA CA 92253 LA QUINTA CA 92253 WCC: OLD REPUBLIC IN WC: MWC10877600 11/01/04 CSLB: 728102, 09/30/04 CCC: B -------------------------- Structure Information ----------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . DWELLG/LODGING/LONG <=L0 Flood Zone . . . . . NON -AO .FLOOD ZONE Other struct info CODE EDITION 2001 CRC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 447.00 PATIO SQ FTG 45.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 2083.00 Permit BUILDING PERMIT Additional desc Permit Fee 741.00 Plan Check Fee 120.41 Issue Date . . Valuation 128508 Qty Unit Charge Per Extension BASE FEE 639.50 29.00 3.5000 THOU BLDG 100,001-500,000 101.50 Permit . . . . . MECHANICAL Additional.desc Permit Fee . . . . 33.00 Plan Check.Fee 2.06 Issue Date Valuation 0 Qty Unit Charge. Per Extension n Page 2 Application Number 04-0000,4358 Date 6/09/04 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 ------------------------------------------------------------------- Permit . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 96.85 Plan Check :gee 6.05 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 2083.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 72.91 447.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.94 Permit PLUMBING Additional desc Permit Fee . . . . 146.25 Plan Check Fee 9.14 Issue Date,'. Valuation 0, Qty Unit Charge Per Extension BASE FEE 15.00 13.00 6.0000 -EA PLB FIXTURE 78.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER'HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/.REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER -SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 Permit . . . . . . GRADING PERMIT Additional desc Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation _ 0 Qty Unit Charge Per Extension BASE FEE 15.00 Special Notes and Comments SFD - LOT 71. PLAN 2. PERMIT DOES NOT:: INCLUDE BLOCK WALL, POOL, SPA OR Page 3 ,Application Number . . . . 04-00004358 t Date 6/09/04 ------------------------------------ Special Notes and Comments ---------------------------------------- DRIVEWAY APPROACH. 75% PLAN CHECK FEE REDUCTION APPLIED -FOR MULTIPLE ISSUANCE OF SAME PLAN TYPE. Other Fees . . . . . . ... . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 12.04 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK -FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK.MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00. STRONG MOTION.'(SMI) - RES. 12.85 ' DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged ..Paid Credited Due , Permit Fee Total 1032.10 .00 .00 1032.10 Plan Check Total 137.66 .00 .00 137.66 Other Fee Total > 2429.89 .00 .00 2429.89 Grand Total 3599.65 .00 .00 3599.65 P.O. BOX 1504 78-495 CALLE TAMPICO N ` LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number: g' Applicant: I ct or Eng' r: i M. f�, VOICE (760) 777 -701 - FAX (760) 777-701 INSPECTIONS (760) 77;-715: Date: —LAV V -O�f nNNrht:aru s mauing Aaoress: Ar t� t or Engineer's( Address: -4—tic. No.: BUILDING PERMIT DECLARATIONS I hereby affirm under penaltyof LICENSED CONTRACTOR'S DECLARATION perjury that I am licensed under provisions of Chapter 9 (Commencing with Section 7000) of Divisi � in full force and eon 3 of the Business and Professionals Code, and my Licens effect. _ �_�p /Cicense Class Tnse No. r% �/1 - -M I hereby affirm under penaltyof OWNER -BUILDER DECLARATION perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to construct, alter, improve. demolish, or repair any structure, prior to its issuance. also requires the applicant for the permit to file a signea statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation Of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation.. himself or herself or through his or her own employees. provided that the improvewill do the work. and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the worts ments are not intended or offered for sale. If, however. the building or Improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (-.) I am exempt under. Sec. . B.d P.C. for this reason Date Owner 1 hereby affirm under penalty of perjury one of the following des arattiionsRS' COMPENSATION DECLARATION I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code. for the performance Of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this ss coo e/� mpensation insurance carier pemtit is !Cartier G � Numberj�� are4not )yfn , In the performance of the work for which this permit Is issued, I sm to an workers'me subject to Ow compensation laws of California, and agree that, if I should become subject to the workers' compensation Provisionsyof so aections to b37 of the Labor Code, I shall forthwith Comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (s100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. I hereby affirm under penalty of perjury that there isa construction lending agencyIOfor ti►e AGENY oC Lender's Name the work for which this Permit is issued (Sec. 3097, Civ. C.). Lender's Address IMPORTANT APPLICANT ACKNOWLEDGEMENT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 • Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of officers, agents and employees for any act or omission related to the work being performed under Or following issuance of this permit. V QuiMa, its 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit or cessation of work for 189 days will subject permit to cancellation. I certify that I have read this application and state that the above information is cortea I agree to comply with all city and county ordinances and state tows relating r building construction, and hereby authorize representatives of this county to enter upon the above mentioned property for inspection purposes. .Date � �` Signature (Applicant or Agent): PREPARED 10/02/09, 16:46:24 INSPECTION HISTORY REPORT - PAGE 1 PROGRAM BP521L 0/00/00 THRU 0/00/00 CITY OF LA QUINTA ----------------------- ' ---------------------- APPLICATION ----------------------------------------------------------`---------------------------: PROPERTY ADDRESS APN Alternate ID STRUCTR PERMIT INSPECTION RESULT DATE/STATUS, INSPECTOR 04 00004358 79814 PARKWAY ESPLANADE N 609-380-998-71 -293232- 000 000 B001 00 BUILDING PERMIT 120 0001 FOOTINGS - 10/04/04 APPROVED ST 000 000 B001 00 BUILDING PERMIT 125 0001 SLAB 10/04/04 APPROVED ST 000 000 B001 00 BUILDING PERMIT 135 0001 ROOF NAIL 11/08/04 APPROVED TM - -.000 000 B001 00 BUILDING PERMIT 140 0001 OKAY TO WRAP 11/15/04 APPROVED TM ' 000 000 B001 00 BUILDING PERMIT 145 0001 FRAMING 11/24/04 DISAPPROVED TM 000,000 B001 00 BUILDING PERMIT 145 0002 FRAMING- 11/30/04 APPROVED TM 000 000 B001 00 BUILDING PERMIT - 150" 0001 INSULATION 11/30/04 APPROVED TM 000 000 B001 00 BUILDING PERMIT 155 0001 LATH 11/30/04 APPROVED TM ' 000 000 B001 00 BUILDING PERMIT 160 0001 DRYWALL NAIL 11/30/04 APPROVED TM 000-000' B001 00- BUILDING PERMIT ----- - _-___.. _. _-�- 199-- 0001 FINAL 2/03/05 APPROVED_. _ TM _. -. 000 000 E01 00 ELEC-NEW RESIDENTIAL 310 0001 ROUGH ELECTRICAL 11/24/04 DISAPPROVED TM 000 000• E01 00 ELEC-NEW RESIDENTIAL 310 0002 ROUGH ELECTRICAL - 11/30/04 APPROVED TM 000 000 E01 00 ELEC-NEW RESIDENTIAL 315 0001 TEMP USE OF PERMANENT POW 12/09/04 APPROVED TM 000 000 E01 00 ELEC-NEW RESIDENTIAL 399 0001 ELECTRICAL FINAL - 2/03/05 APPROVED TM 000 000 GP 00 GRADING PERMIT. 197 0001 GRADING FINAL 2/03/05 APPROVED TM - 000 000 - MO1 00 MECHANICAL. 405 0001 ROUGH MECHANICAL 11/24/04 DISAPPROVED TM . 000 000 MO1" 00 MECHANICAL 405 0002 ROUGH MECHANICAL 11/30/04 APPROVED TM ' 000 000 MO1 00 MECHANICAL 499 0001 MECHANICAL FINAL 2/03/05 APPROVED TM - 000 000 PO1 00 PLUMBING .200. 0001 UNDERGROUND PLUMBING 9/14/04 APPROVED GH - ' 000 000 PO1 00 PLUMBING 210' 0001 SEWER CONNECTION 10/26/04 DISAPPROVED - TM - RES COMM: NOT READY 000 000 PO1 00 PLUMBING - 210 0002 SEWER CONNECTION 10/29/04 APPROVED TM 000 000 P01 00 PLUMBING 230 0001 ROUGH PLUMBING 11/24/04 DISAPPROVED TM 000 000 PO1. 00 PLUMBING 230 0002 ROUGH PLUMBING 11/30/04 APPROVED TM UUU UUU 1JU-1 UU, PLUMBING 245 UUU1 SHUWEH VAN ii/ 3U/ APYHUVEL TM 000 000 PO1 00 PLUMBING 235 0001 GAS LINE / GAS TEST 12/09/04 APPROVED TM . .PREPARED 10/02/09, 16:46:24 INSPECTION HISTORY REPORT - PAGE 2 PROGRAM BP521L '0/00/00 THRU 0/00/00 CITY OF LA QUINTA . ---------------- ---------------------------------------------- APPLICATION PROPERTY ADDRESS APN Alternate ID STRUCTR PERMIT - - INSPECTION RESULT DATE/STATUS - INSPECTOR -------------------------------------------------------------------------------------------------------------------------------- 04 00004358 CONTINUED - 000 000 PO1 00 PLUMBING - 299 0001 PLUMBING FINAL 2/03/05 APPROVED TM. r� r i r. Deseft s ENERGY - CADEC Semcee P0. Box 821 Ph/Fax (760) 564-2044 Rancho Mirage, CA 92270 Cell: (7601250-1852 Email: DESNRG CMAOL.COM CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) TAPESTRY @ ESPLANADE PH 9 DATE TESTED 02 Project Title Date PARKWAY ESPLANADE NORTH LA QUINTA CA roLec Address 909-275-0204 TONY PASCANITE Builder Contact Telephone RICHARD KROWN 760-250-1852 LENNAR HOMES Builder Name PLAN 2 1 UNIT Plan Number HERS Rater Telephone Sample Group Number CF -4R i #CCNRK613292 LOT 71-9 1 OF 1 CertifyiV96affiffe Date Sample Lot NLmber Firm: DESERT ENERGY SERVICES LLC HERS Provider: CHEERS Street Address: P.O. BOX 621 City/State/Zip: RANCHO M °RAGE, CA. 922-70 Copies to: Builder, HERS Provider HERS RATER COMPLIANCE STATEMENT The house was: N Tested ❑ Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses idertified on this form comply with the diagnostic tested compliance requirements as checked on this form. ® The installer has provided a copy of CF -6R (Installation Certificate. ® Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ® Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination wit cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ® MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measuted Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM 107 If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here 2000 If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = 5.35 Check Box for Pass or Fail (Pass=6% or less) Pass ® THERMOSTATIC EXPANSION VALVE (TXV) Fail ®Yes ❑ No Thermostatic Expansion Valve is installed pnd Access is ® ❑ provided for inspection Certificate of Insulation Your home has been insulated with Certain Teed Fiberglass insulation products, which are designed for today's safety standards and tomorrov.?s energy requirements. O f=iberglass is inorganic and therefore permanently noncombiist hlr-, -;6 it !foes not have to be trcotcd W vith fire -retardant chemicals that wJl likely lose their effectiveness over time_ It has not been treated r with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it LO N settle over time as may other insulation materials. O This also certifies that insulation have been professionally instated in this home to provide the -- following thermal performance. Job Name: Lennar Homes, Inc. Tract: 29323 Plan# 2 Phase: 9 Lot No: 71 Job Address: SPR - 79-814 Parkway Esplanade North, La Quinta, CA Ceiling Area: R-38 blown -in fiberglass insulation Garage Ceiling: Non -Access: _. c _ With -Living -Above & Slop Ing -Areas - L Exterlor Walls R-13 batt insulation overhangs: Access Attic: U) With Living Above E Between Floors: - Interior Walls: o_ Subcontractor ...O J Insulation, Inc. 7 �r /# > � O 72-227 Ade laid St. Thousand Palms, CA 92276 N Signed: 1ti1 �. � �M -- _—_ ----- - - - LO o Mike Dickerson, General Manager - Palm Springs Branch LO R -means resistance to heat flow. The h,gher the R -value, th.e greater the insulating power. Ask your builder for the fact sheet on R -values. Keep this certificate with your other O valued papers. If you ever sell this home, this certificate should be passed on to the buyer. U_ . ,- ;,.CITY..0f 0UINTA � BUILDING & SAFETY DEPARTMENT AFM OF T a 777=:7012 INSPECTION REQUEST LINE 777-7153 Owner ,NNAR-HOMES-'-OF'CALIFORNIA Contractor LENNAR HOMES OF CALIFORNIA Permit Number 04;4358:., ..: POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS 79-81.4 PARKWAY ESPLANADE N SFD —.LOT 71 PLAN 2. PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPROACH. TYPE OF INSPECTION DATE INSP. TEMPORARY POWER SETBACKS U/G PLUMBING'/ WASTE U/G ELECTRICAL/ GROUNDING FOOTINGS / STEEL CONCRETE SLAB O 0 If DO NOT POUR CONCRETE UNTIL ABOVE SIGNED ROOF NAIL / PRE -ROOF / a� OKAY TO WRAP FRAMING COMBINATION ROUGH ELECTRIC 3G a ROUGH PLUMBING ROUGH MECHANICAL INSULATION o `/ COVER NO WORK UNTIL ABOVE SIGNED INTERIOR GYP. BD. DRYWALL t EXTERIOR LATH _ GAS TEST / To 7/Ts SEPTIC ABANDONMENT SEWER CONNECTION 110 .2 f/0 SEPTIC / GREASE INTERCEPTOR II� MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL/ SPA/ WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS. U/G PLUMBING U/G GAS U/G ELECTRICAL PRE -PLASTER ALARMS / BARRIERS FINAL INSPECTIONS TEMP. USE OF PERMANENT POWER 11,2_01a5' .,2C oS j ELECTRICAL. PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT. 2 - FINAL %FINAL / JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE -RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING