04-4323 (SFD)E3 �
BUILDING & SAFETY DEPARTMENT
P.O. BOX 1504 (760).777-7012
x' F'I1•� 78-495 CALLS TAMPICO FAX (760) 777-7011
Ln QUINTA,' CALIFORNIA 92253 INSPECTION. REQUESTS (760) 777-7153
BUILDING PERMIT
Application Number, c0:40=0=00432:3 Date 6/09/04
Property Address "!�-7-9"8-5 ARKWAY ESPLANPDE N
APN: :609-380-998-53 .-293232
Application description DWELLING -,SINGLE FAMILY DETACHED
Property Zoning . . . . . LOW DENSITY RESIDENTIAL
.Application valuation 152664
Owner Contractor
-------------------------
LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC
-78401 HIGHWAY 111, STE C 78401 HIGHWAY 111, SUITE'C
LA QUINTA, CA LA QUINTA CA 92253
LA QUINTA CA 92253
WCC: OLD REPUBLIC IN
WC: MWC1C817600 11/01/04
CSLB: 7281C2 09/30/04
CCC: B
------------=------------ Structure Information ------- -----------------
Construction Type .TYPE V - NON RATED
Occupancy Type . . . . DWELLG/LODGING/LONG <=10
Flood Zone . . . . . . NON -AO FLOOD ZONE
Other struct info . . . . CODE EDITION 2001 CRC
# BEDROOMS 5.00
FIRE SPRINKLERS : 'NO
GARAGE SQ FTG 425.00
PATIO "SQ FTG" 53.00
NUMBER OF UNITS 1:00
FIRST -FLOOR SQ FTG 2511.00
------------ - -----=---- - --- - ------------------ -- Q---- ------=--= -----=
Permit. . . . BUILDING PERMIT
Additional desc
Permit Fee825.00 Plan Check Fee 536.25
Issue Date . . Valuation 152664
Qty Unit Charge' Per Extension
BASE FEE 639.50
53.00 3.5000 THOU BLDG 100,001-500,000 185.50
-----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL -
Additional'desc
Permit Fee 46.00 Plan Check -Fee 11.50
Issue Date Valuation 0
Qty Unit Charge Per Extension
P.O. Box L'LE Tait
78-495 CALL$ TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
Application Number:
Applicant:
U
Applicant's Mailing Address: : ,
VOICE (760) 777.701:
FAX (760) 777.701 •
INSPECTIONS (760) 777-715:
Date: % — Ap - 0
ic. No. 9_�3 Icj '
BUILDING PERMIT DECLARATIONS
I hereby affirm under penally of LICENSED CONTRACTOR'S DECLARATION
y once a that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my Likens al full force and effect.
,------License Class_ ✓I/f
-p License No. 1 v o I
I hereby affirm under penaltyof OWNER -BUILDER DECLARATION
perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5. Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve• demolish, or repair any structure, prior to its issuance. also requires the applicant for the permit to file a signee
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation,will do the work, and the structure is not intended or offered for sale (Sec. 7044•
Business and Professions Code: The Contractors' State License Law does not apply to an owner of Property
himself or herself or through his or her own employees. provided that the improvements are not intended or ffered for dsale. s or r If. however. the proves nbuildi wh tloes the wont
sold within one year of completion• the owner -builder will have the burden of proving that he or she did not build or improve for the u improvement is
U I, as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors,State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to
the Contractors' State License Law.).
U 1 am exempt under Sec. , BA P.C. for this reason
Date Owner
I hereby affirm under penaltyof WORKERS' COMPENSATION DECLARATION
perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code. for the Perforimance
Of the work for which this permit is issued.
1 ha3vse and will maintain workers' compen n insurance, as required by Section 3700 of the Labor Code. for the performance of the work for which this
,,-Carrier _� I (( Ue� j��� � 7ensati Pol ty Numbermego&L
pemut is
clertify Etat, r the performance of the work for whichmit is ;slued. I shall no an
compensation laws of California. and agree that, if I should become subject to the workers' any Person in any manner so as to become subject to the workers'
forthwith comply with those provisions. pensation provisions of Section 3700 of the Labor Code, I shall
�
Date f
/ ` plignt
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL. AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO. ONE HUNDRED THOUSAND DOLLARS ($100.000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST. AND ATTORNEY'S FEES.
I hereby affirm under penalty of perjury that there is a construction lending
CONSTRUCTION LENDING
AGENCY
oC � work for which this
9 ge ry permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address
IMPORTANT APPLICANT ACKNOWLEDGEMENT
Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner• and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Cluinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 dayti horn date of issuance of such permit or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes.
Date C-0 (, mature (Applicant or Agent):
v
Page
2
Application
Number
. . . 04-00004323 Date
6/09/04
Qty
Unit Charge
Per
Extension
BASE FEE
15.00.
\
1.00
9.0000
EA MECH FURNACE <=100K
9.00
1.00
9.0000
EA MECH B/C <=3HP/100K BTU
.9.00
'1.00
6.5000
EA MECH VENT FAN
6.50
1.00
6.5000
EA MECH EXHAUST HOOD
6.50
Permit .
------------------------------
. . . . ELEC-NEW RESIDENTIAL
Additional
desc
Permit.Fee
111.39 Plan Check Fee
27.85
Issue Date
Valuation ."
.0
Qty
Unit Charge
Per
Extension
BASE,FEE
15.00
2511.00
.0350
ELEC NEW RES - 1 OR 2 FF.MILY
87.89
425.00
.'0200
ELEC GARAGE OR NON-RESIDENTIAL
8.50
--------------------
Permit •.
--------------------------------------------------------
. . . . .. PLUMBING
Additional
desc
Permit Fee
. . . .
170.25. Plan Check Fee
42.56
Issue Date
. . . .
Valuation
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
17.00
6.0000
EA' PLB FIXTURE
102.00'
1.00
15.0000
EA PLB BUILDING SEWER
15.00
1.00
7.5000
EA PLB WATER HEATER/VENT
7.'50
1.00
3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
5.00
.7500.EA
PLB GAS PIPE >=5.
3.75
1.00
15.0000
EA PLB-GAS METER
15.00
Permit .
. . . . . GRADING PERMIT
Additional
desc
Permit Fee
. . . .
15.00 Plan Check Fee
.00
Issue Date
Valuation . . . .
0
Qty
Unit Charge
.Per
Extension
BASE FEE
15.00
Special Notes
and Comments
SFD - LOT
53. PLAN 4Y.
PERMIT DOES NOT
Deseft
ENERGY - CA0EC
S�� —
P0. Box 621 Ph/Fox (760) 564-2044
Rancho Mirage, CA 92270 Cell: (7601250-1852
Email: DESNRG aOAOL.COM
CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R
TAPESTRY @ ESPLANADE PH 9 DOTE TESTED 02-01-05
Project Title Date
PARKWAY ESPLANADE NORTH LA QUINTA CA LENNAR.HOMES
roc Address Builder Name
T 909 -275-020I4 ONY PASCANITE PLAN 4Y 2 UNIT
Builder Contact Telephone Plan Number
RICHARD KROWN 760-250-1852 GROUP 5
HERS Raters . Telephone Sample Group Number
#CCNRK61
Certifying Signature
Firm: DESERT ENERGY SERVICES LLC
Street Address: P.O. BOX 621
Copies to: Builder, HERS Provider
02-02-05 LOT 53-9
Date Sample Lot Number
HERS Provider: CHEERS
City/State/Zip: RANCHO MIRAGE, CA. 92270
HERS RATER COMPLIANCE STATEMENT
The house was: ❑ Tested ® Approved as part of sample testing but was not tested
As the HERS rater providing diagnostic testing and field verification, I certify that the houses idertified on this form comply
with the diagnostic tested compliance requirements as checked on this form.
❑ The installer has provided a copy of CF -6R (Installation Certificate.
❑ Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts)
❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth
backed, rubber adhesive duct tape to seal leaks at duct connections.
❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage)
Duct Pressurization Test Results (CFM @'25 Pa)
Test Leakage Flow in CFM
If fan flow is calculated as 400cfm/ton x number of tons enter calculated
value here
If fan flow is measured enter measured value here
MeasLred
values
Leakage Percentage (100 x Test Leakage/Fan Flow) _
Check Box for Pass or Fail (Pass=6%, or less) ❑
Pass Fail
❑ THERMOSTATIC EXPANSION VALVE (TXV)
❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is ❑ ❑
provided for inspection
CL Certificate of Insulation
Your home has been insulated with Certain Teed Fiberglass' insulation products, which are designed
for today's safety standards and tomorrov/s energy requirements.
41
0
(D
LO
ru
O
Lo
r`
s
Q_
O
Fiberglass is inorganic and therefore permonontiy noncombuet-blo; so it done not have to be treatod
with fire -retardant chemicals that will likely lose their effectiveness over time_ It has not been treated
with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it
settle over time.as may other insulation materials.
This also certifies that insulation have been professionally installed in this home to provide the
follmving thermal performance.
Job Dame: Lennar Homes, Inc. Tract: 29323 Plan# 4Y Phase: 9
Lot No: 53 Job Address: SFR - 79-851 Parkway Esplanade Forth, La Quinta, CA
Ceiling Area: R-38 blown -in fiberglass insu'ation Garage Ceiling; Non -Access:
With Living Above & Sloping Areas
Exterior Walls R-13 batt insulation Overhangs: Access Attic:
With Living Above
Between Floors: Interior Walls:
Subcontractor ...0 J Insulation, Inc.
72-227 Adelaid St, Thousand Palms, CA 92276
Signed,
Mike Dickerson, General Manager- Palm Springs Branch
R -means resistance to heat flow. The higher the R -value, the greater the insulating power.
Ask your bui."--der for the fact sheet on R -values. Keep this certificate with your other
valued papers. If you ever sell this home, this certificate should be passed on to the buyer.
CITfi(��F QUQUINTA
ti.: B:U'ILDIN.G:& SAFEtY-DEPARTMENT
777- 1012
INSPECTIONvREQUEST.LINE
777-7153
OwnerLENNAR HOMES OF CALIFORNIA
ContractorLENNAR. HOMES OF CALIFORNIA
Permit Number 04-4323
POST ON JOB IN CONSPICUOUS PLACE
INSPECTOR MUST SIGN ALL APPLICABLE SPACES
JOB ADDRESS 79-851 PARKWAY ESPLANADE N
SFD — LOT 53 PLAN 4Y. PERMIT DOES NOT
INCLUDE BLOCK WALLS, POOL, SPA OR
DRIVEWAY APPROACH.
TYPE OF INSPECTION DATE INSP.,
TEMPORARY POWER
SETBACKS
U/G PLUMBING /WASTE
U/G ELECTRICAL / GROUNDING
FOOTINGS / STEEL
CONCRETE SLAB
DO NOT POUR CONCRETE UNTIL ABOVE SIGNED
ROOF NAIL/ PRE -ROOF m Z e 9
OKAY TO WRAP
FRAMING COMBINATION
ROUGH ELECTRIC
ROUGH PLUMBING
ROUGH MECHANICAL
INSULATION
COVER NO WORK UNTIL ABOVE SIGNED
INTERIOR GYP. BD. DRYWALL p • r
EXTERIOR LATH
GAS TEST l.2z 30 Zp�/
SEPTIC ABANDONMENT
SEWER CONNECTION
SEPTIC / GREASE INTERCEPTOR
MASONRY INSPECTIONS
FOOTINGS / STEEL
BOND BEAM
POOL / SPA / WATER FEATURE INSPECTIONS
PRE-GUNITE / SETBACKS
U/G PLUMBING
U/G GAS
U/G ELECTRICAL
PRE -PLASTER (ALARMS/ BARRIERS
FINAL INSPECTIONS
TEMP. USE OF PERMANENT POWER y ,'Z,Z1111
ELECTRICAL
PLUMBING
MECHANICAL
PUBLIC WORKS DEPARTMENT
COMMUNITY DEVELOPMENT DEPT. Iti
FINAL / JOB COMPLETED
ABOVE APPROVALS DO NOT INCLUDE RIGHT TO
TURN ON UTILITIES OR OCCUPY BUILDING