04-4361 (SFD)4OF
BUILDING & SAFETY DEPARTMENT
P.O. Box 1504 (760).777-7012
78-495-C. LE TAMPICO FAX (760) 777-7011
71
LOA I A
r
LOA Q u i Nrtt CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153
- � t
H'AV 16 20047.
BUILDING PERMIT'
§
App caul, iqb7mbe. .
. . 04 -0000^4361 Date
6/09/04
Property Address_'. ...
. . . 7 9-9-82_PARKV4AY ESPLANADE N,
APN.:
.609-380-998-74 -293232-
Application description
DWELLING - SINGLE FAMILY DETACHED
Property Zoning . . .
. . . . LOW DENSITY RESIDENTIAL
Application valuatibn*
. . . .. 143155
Owner
Contractor'
------------------------
LENNAR HOMES OF CALIFORNIA
------------------------
LENNAR HOMES OL7 CALIFORNIA
INC
.78401 HIGHWAY lll,.STE
C. 78401 HIGHWAY Ill, SUITE
C
LA QUINTA, CA
LA QUINTA
CA 92253
LA QUINTA
CA 92253
WCC: OLD REPUBLIC
IN
WC: MWC10877600
11/01/04
CS , LB: 728102,
09/30/04
CCC: B
------ Structure Information
-SFD
------
Construction Type . .
. . . .. TYPE V NON RATED..
Occupancy Type
DWELLG/LODGII,4G/CONG <=10
Flood Zone. . . . ...
. . NON -AO FLOOD ZONE
'Other struct info
CODE EDITION 2001'
. CBC
# BEDROOMS
5.00
FIRE SPRINKLERS NO
GARAGE,SQ FTG
418.00
PATIO SO FTG
45.00
NUMBER OFUNITS1.00
FIRST FLOOR SQ FTG
2349.00
Permit
BUILDING PERMIT'
Additional desc
Permit Fee . . . .
793.50 Plan Check Fee
515.78
Issue Date . . . .
Valuation . . . .
143155
Qty Unit Charge
Per
Extension
BASE PEE
639.50
44.00 3.5000
------------------------------------------------------------------------------
THOU BLDG 100,001-500,000
154.00
Permit . . . . . .
MECHANICAL
Additional. de'sc
Permit.,Fee
47.00 Plan Check Fee
6.00*
Issue Date . . . .
Valuation
0
Qty Unit Charge.
Per
Extension
P.O. BOX
78-495 CALLELLE TAMPIt".O
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
Application Number: U —LIAV
Applicant:
Applicant's Mailing Address:
or
itect or
&+ cel 9a -70
tic. No.: 3a 3�S
BUILDING PERMIT DECLARATIONS
VOICE (760) 777-701,1
FAX (760) 777•-011
INSPECTIONS (760) 777-715
Date:61� . p
ress:
I hereby affirm under penalty of LICENSED CONTRACTOR'S DECLARATION
Y Perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
I ,and my License i al full -force and effect.
License Class_ L ___[1Cense No. �I Qa—
_---Date- lX— rQ (' fractor�
I hereby, affirm under penaltyof OWNER -BUILDER DECLARATION
perjury that I am exempt from the Contractors' State License Law for the following reason (Sec 7031.5. Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish• or repair any structure• prior to its -issuance, also requires the applicant for the permit to file a signed
statement that h- or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work• and the structure is not intended or offered for sate (Sec. 70x4,
Business and Professions Code: The Contractors' State License Law does riot apply to an owner ofproperty
himself or herself or through his or her own employees• provided that the improvements are not intended offered for dsale.s or I Ifphowever. t roves theon. a di wh does the worts
sold within one year of completion, the owner -builder will have the Durden of proving that he or she did not build or improve for the u mprovement is
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (sec. 7044• Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon• and who contracts for the projects with a conGapor(s) license pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , B.d P.C. for this reason
Date Owner
I hereby affirm under penaltyof WORKERS' COMPENSATION DECLARATION
perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation. as provided for by Section 3700 of the Labor Code• for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the tabor Code. for the performance of the work for which this
su Iwo Qr y compensation ce carrier poli m are: permit is
,_Carrier 71/1 / —Policyn
Number
_ I certify Hiall. in the performance of the work for which this permit is issued. I shall not employ an workers'
compensation laws of California, and agree that• if I should become subject to the workers' compensation provis onsro Sectionso as to D37 of theme �bft
to or ode I shall
forthwith Comply with those provisions.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
I hereby affirm under penalty of perjury that there is a construction CONSTRUCTION LENDING AGENCY
lending agency for the performance of the work for which this
Lender's Name permit is issued (SCC. 3097, Civ. C.).
Lender's Address
IMPORTANT APPLICANT ACKNOWLEDGEMENT
Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quints, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not Commenced within 180 day from date of issuance of such permit or
cessation of work for 180 days will subject permit to cancellation.
I Certify that I have read this application and state that the above information is comect. I agree to Comply with all city and county ordinances and state Is" relating to building
construction. and hereby
authharize representatives of this county to enter upon the above-Menbone property for inspection purposes.
Ste Signature (Applicant or Agent):
1 ,%v`�t'fiAYi4;S$-
'
Page
2
_Application Number
.
. . . . 04-00004361 Date
6/09/04
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
1.00
9.0000
EA MECH FURNACE <=100K
9.00
1.00
16.5000
EA MECH B/C >3-15HP/>100K-EOOKBTU
16.50
1.00
6.5000
EA MECH EXHAUST HOOD
6.50
----==----------------------------------------------------------------------
Permit . . .
. .
ELEC-NEW RESIDENTIAL
Additional desc
Permit Fee .
. . .
105.58 Plan Check Fee
26.40
Issue Date
. . .
Valuation . . . .
0
Qty Unit
Charge
Per
Extension
BASE FEE
.15.00
2349.00
0350
ELEC NEW RES - 1 OR 2 FAMILY
82.22
418.00
.0200
ELEC GARAGE OR NON-RESILENTIAL
8.36
------------------------------------------------------------------.----------
Permit ...
. .
PLUMBING
Additional desc
Permit Fee .
. . .
164.25 Plan Check Fee
41.06
Issue Date
Valuation . . . .
0
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
16.00
6.0000
EA PLB FIXTURE
96.00
1.00
15.0000
EA. PLB BUILDING SEWER
15.00
1.00
7.5000
EA PLB WATER HEATER/VENT
7.50
1.00
3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA PLB LAWN SPRINKLER SYSTEM
.9.00
5.00
.7500
EA PLB GAS.PIPE >=5
3.75'
1.00
------------------------------------------------------------------------------
15.0000
EA PLB GAS METER
15.00
Permit . . .
... .
GRADING PERMIT
Additional desc
Permit Fee .
. . .
15.00 Plan Check Fee
.00
Issue Date
Valuation
0
Qty Unit
Charge
Per
Extension.
BASE FEE.
15.00
Special Notes
and Comments
SFD - LOT 74.
PLAN 2YR.
PERMIT DOES NOT
Page
3
Application Number
04-00004361
Date
6/09/04
------------------------------------------------------------------------------
Special Notes and Comments
INCLUDE BLOCK -WALL,
POOL,' SPA
OR
DRIVEWAY APPROACH.
Other Fees ... .
. . . . .
ART
IN PUBLIC PLACES -RES
..00
DIF
COMMUNITY CENTERS -RES
97.00.
DIF
CIVIC CENTER - RE;S
366.00
ENERGY
REVIEW FEE
51.58
DIF
FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK FEE
00
DIF
LIBRARIES -RES
225.00
DIF
PARK MAINT FAC - RES
5.00
DIF
PARKS/REC - RES
502.00
STRONG
MOTION (SMI) - RES
14.3.1
DIF
STREET MAINT FAC -RES
15.00
DIF
TRANSPORTATION - .SES
1098.00
Fee summary
Charged
Paid Credited
Due
Permit Fee Total
1125.33
.00 OD.
1125.33
Plan Check Total
589.24
.00 .ONS
589.24
Other Fee Total
2470.89
.00 .00
2470.89-
470.89.Grand
GrandTotal
4185.46
.00 .00
4185.46
Certificate of Insulation
Your home has been insulated with Certain Teed Fiberglass insulation products, which are designed
for today's safety standards and tomorrow's energy requirements.
Fiberglass is inarpanir. anri therefore p4rm3nontly noncombustible, so it flues out have to be treated
vr,th fire -retardant chernic-als that will likely lose their effectiveness over time. It has not been treated
with chemicals that can corrode erring or metal. Fiberglass will not absorb moisture nor will it
settle over time as may other insulation materials.
This also certifies that insulation have been professionally installed in this home to provide the
following thermal performance.
Job Name: Lennar domes, Inc. Tract: 29323 Plan# 2Y Phase: 9
Lot No: 74 Job Address: SFR -79-862 Parkway Esplanade North, La Quinta, CA
Ceiling Area: R-38 blown -in fiberglass Insulation Garage.Ceiling: Non -Access:
With Living Above & Sloping Areas
Exterior Walls R-13 batt insulation Overhangs: Access Attic:
With Living Above
Between Floors: Interior Walls:
Subcontractor...0 J Insulation, Inc.
72-227 Ade?aid St, Thousand Palms, CA 92276
a Signed: M O`>�J�C'�11JZItvr
M Mike Dickerson, General Manager - Palm Springs Branch
0
o R -means resistance to heat flow. The higher the R -value, the greater the insulating power.
m. Ask your builder for the fact sheet on R -values. Keep this certificate with your other
0 valued papers. if you.ever sell this home, this certificate should be. passed on to the buyer.
a,
LLI
�v
Damo��ii F7
Mort =
ENERGY C A 0 E C
Samcm —
P0. Box 821
Rancho Mirage, CA 92270
Email: DESNRG AAOL.COM
Ph/Fox (760) 564-2044
Cell: (760) 250-1852
CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R
TAPESTRY @ ESPLANADE PH 9
Project Title
79-862 PARKWAY ESPLANADE NORTH LA QUINTA CA
roc Address
I909-275-0204
TONY PASCANITE
DATE TESTED, 02-01-05
Date
LENNAR HOMES
Builder Name
PLAN 2Y 1 UNIT
Builder Contact Telephone Plan Number
RICHARD KROWN 760-250-1852 GROUP 5
HERS Rater Telephone Sample Group Number
;7 #CCNRK613292 02-02-05 LOT 74--9
Certifying Signature Date Sample Lot Number
Firm: DESERT ENERGY SERVICES LLC HERS Provider: CHEERS
Street Address: P.O. BOX 621
Copies to: Builder, HERS Provider
City/State/Zip: RANCHO MIRAGE, CA. 92270
HERS RATER COMPLIANCE STATEMENT
i
The house was: ❑ Tested ® Approved as part of sample testing but was not tested
As the HERS rater providirig diagnostic testing and field verification, I certify that the houses iden•.ified on this form comply
with the diagnostic tested compliance requirements as checked on'this form.
❑ The installer has provided a copy of CF -6R (Installation Certificate.
❑ Distribution system �s fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts)
❑ Where cloth backed,I rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth
backed, rubber adhesive duct tape to seal leaks at duct connections.
❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE OREDIT
Duct Diagnostic LeakagelTesting Results (Maximum 6% Duct Leakage)
i
Measured
Duct Pressurization Test Results (CFM @ 25 Pa) values
! Test Leakage Flow in CFM
If fan flow is calculated as 400cfm/ton x number of tons enter calculated
value here
If fan flow is measured enter measured value here
Leakage Percentage (100 x Test Leakage/Fan Flow) _
Check Box for Pass or Fail (Pass=6% or less) ❑ ❑
Pass Fail
❑ THERMOSTATIC EXPANSION VALVE (TXV)
i! I.
-:CITY OF LA QUINTA
- ..BUILDING & SAFETY DEPARTMENT
X777-7012
- INSPECTION REQUEST LINE
777-7153
Owner LENNAR HOMES OF CALIFORNIA
Contractor LENNAR HOMES OF CALIFORNIA
Permit Number y0'44361= y
POST ON JOB IN CONSPICUOUS~PLACE
INSPECTOR MUST SIGN ALL APPLICABLE SPACES
JOB ADDRESS 79-862 PARKWAY ESPLANADE N
SFD — LOT 74 PLAN 2Y. PERMIT DOES NOT
INCLUDE BLOCK WALLS, POOL, SPA OR
DRIVEWAY APPROACH.
TYPE OF INSPECTION I DATE I INSP.
TEMPORARY POWER
U/G PLUMBING / WASTE O
U/G ELECTRICAL / GROUNDING
FOOTINGS / STEEL
CONCRETE.SLAB
DO NOT POUR CONCRETE UNTIL ABOVE SIGNED
ROOF NAIL/ PRE -ROOF f m
OKAY TO WRAP
FRAMING COMBINATION
ROUGH ELECTRIC l
ROUGH PLUMBING
ROUGH MECHANICAL
INSULATION
COVER NO WORK UNTIL ABOVE SIGNED
INTERIOR GYP. BD. DRYWALL
EXTERIOR LATH 1 m o
GAS TEST
SEPTIC ABANDONMENT
SEWER CONNECTION /O 211 d</
SEPTIC / GREASE INTERCEPTOR
MASONRY INSPECTIONS
FOOTINGS / STEEL
BOND BEAM
POOL / SPA / WATER FEATURE INSPECTIONS
PRE-GUNITE /.SETBACKS
U/G PLUMBING
U/G GAS
U/G ELECTRICAL.
PRE -PLASTER (ALARMS/ BARRIERS
FINAL INSPECTIONS
TEMP. USE OF PERMANENT•POWER
ELECTRICAL
PLUMBING
MECHANICAL
PUBLIC WORKS DEPARTMENT
COMMUNITY DEVELOPMENT DEPT.
FINAL / JOB COMPLETED
ABOVE APPROVALS DO NOT.INCLUDE RIGHT TO
TURN ON.UTILITIES OR OCCUPY BUILDING