Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11-0922 (SOL)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number.1.1,00000922 Property Address: '79963• PARKWAY ESPLANADE N APN: 609-380-999-14 -293234- Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 50000 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: KOSTELECKY JASON D & JODI R 79963 PARKWAY ESPLANADE N LA QUINTA, CA 92253 Contractor: Applicant: Architect or Engineer: BLS CONSTRUCTION INC 77-770 ROBIN ROAD PALM -DESERT, CA 92211 (760)275-9116 Lic. No.: 550864 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/05/11 ,P[t6,2011 11 CITY OF LLA QUINTA FNaWE ^SPT Ivl� ' UC CONTR TOR'S DECLARATION WORKER'S COMPENSATION DECLARATION 'I hereby affirm under penalty of rjury that 1'am ' ed under rovisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: .Section 7000) of Division 3 of th Business and Profess Is C e, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers'. compensation, as provided Licen Class: B1 U a No.: 550864 - 'for by Section 3700 ofthe tabor Code, for the performance of the work for which this permit is Date: I � mractor. issued. I have and will maintain workers' compensation insurance; as required by Section 3700 of the Labor V/ Code, for the performance of the work for which this permit is issued. -My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy. number are:. -.I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the .Carrier STATE FUND - P r 1932584-'2011 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the Rormance of ork for w i his permit is issued, I shall, not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the. person in any m ner so as to be 'act to the orkers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if should become subject t workers' compensation provisions of. Section License Law (Chaptdr 9 (commencing with Section 7000) of Division 3 -of the Business and Professions Code) or 3700 of the Labor de, I shall forthwitl co ly' those provisions. - that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by 'cant: any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$5001•: ate: L 1—) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and . the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING:- FAIL E TO SECURE WORKERS' COMPENSATION. COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to -an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself'or herself through his or her own employees, provided that the DOLLARS ($100,000): IN ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving thathe or she did not build or improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT (_) I, as owner.of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the ' 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 I am exempt under Sec. , BAP.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: I PL LQPERMIT of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such cation of work for 180 days will subject permit to cancellation. I certify that I have read this application and sta that the above i mation is cor ct. I agree to comply with all city and county ordinances and state laws relati g to buildi truc , and eby authorize representatives of t . county to enter upon above-mentione property for ins ion ses. Date: S' ature (Applicant or Agent): 0 Application Number . . . . . 11-00000922 Permit . . . ELEC-MISCELLANEOUS Additional.desc . Permit Fee . . . . 41.00 Plan Check Fee 10.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/02/12 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 15.0000 EA ELEC PWR APP >10 TO <=50 15.00 1:00 11.0000 EA .ELEC MISC, 11.00 Permit . . . SOLAR PERMIT Additional desc . Permit F,ee.. 28.50 Plan Check Fee 7:13 Issue Date Valuation . . . . 50000 Expiration Date 4/02/12 Qty Unit Charge Per Extension BASE FEE 15.06 1.0A 4.5000 EA SOLARCOLLECTOR <'1000 4.50 3:00 3.0000 EA SOLAR -EQUIP MISCELLANEOUS 9.00 Special .Notes and= Comments 10.8kW SOLAR ARRAY"- (46):-23OW CANADIAN' SOLAR -PANELS. W/..:(2). 3,000W. & (1)' 6000W . POWER -ONE AURORA INVERTERS .(782SF]"2010 CALIFORNIA ELECTRICAL -CODE. October 4, 2'011 3:51:41 PM AORTEGA ---------------.----_------------------------------------------------- Other Fees . . . . . BLDG STDS ADMIN (SB1473) 2.00 Fee summary. Charged Paid Credited Due Permit.Fee Total 69.50 .00` 00 69.50 Plan Check Total 17.38 .00 ..00. 17.38 Other Fee Total 2.00 .00 .00 2.00 Grand Total 88.88 .00 00 88.88 LQPERMIT Bin # City ofla La Quin ; Building & Safety. Division .' P.O. Box .1.504, 78-495-Calle Tampico La ,Quinta; CA 92251- (760) 777-7012 Building Permit.Application and,Tracking Sheet Permit #. �. cl Z .Z Project Address:�) G 6 3 Owner's Name: S& 0 1 �:. nodi Bleck A. P. Number: Address: _71 9 ctt lU Legal Description: City, ST, Zip: Lc- i (.+ a 3 Contractor: d...a; e e,3 56'1Gt vY vii: vy Telephone: �# Address: - �j� (A LP n ntl11' P l kC't iD Project Description:. City, ST, Zip: f t ( M AeSe-(� C. c, r l f Telephone: � �U % � 6 � Z4 la S'iF2}iL1${it'Ch.''-i�4?Y%{:+.i':i:}�Y;iMU N� ?irk"�a;'n'�`<�;;`gtv�f . State Lie. # : City Lie. C Arch., Engr.,' Designer: Address: City, ST, Zip: Telephone: State Lie. #: F w:<.n,, N;: Construction T Occupancy: Project type (circle one): New Add'n Alter Repair Sq. F[.: #Stories: # Units: Demo Name of Contact Person: l�iPt, v Telephone # of Contact Person: 3 11_ 0 C) Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACKING PERMI[T FEES Plan Sets Pian Cheek submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit A. Truss Calcs. Called Contact Person P1 an Check Balance. Title 24 Calcs. Plans picked up Construction. VAW— Flood plain plan Plans resubmitted Mechanical Grading plan 2q° Review, ready for corrections/issue Electrical t� Subcontactor List Called Contact Person Plumbing Grant Deed Pians picked up -71 S M.I. H.O.A. Approval Plans resubmitted Grading .�. IN HOUSE:- Review, ready for correctio ue Developer. Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 5 «1%o1"« -w 01to.* Residential Optional Calculation 9/25/1997 united States Solar a.,•. Version 2010H STEP 1 Article 220.82 (B) (1),(2) t Jason Kostelecky �• ft `!!:: 2400 General lighting load 7,200VA 79 -963 -Parkway Esplanade North 2 Small Appliance 3;000 VA ' La Quinta, CA. 92253 1 Laundry circuit 1,500 VA 760-275-8869 Gen.Lgt, Sm App.& Laun. Load 11,700 VA 10/4/2011 13:50 STEP 2 Article 220.82 (C) )] A/C Condenser & Fixed Electric Space Heating Ston ::!► 7,130 VA" AHU118ks1 !' A/C *2 fes: VA AHU 2 ; Select , �I A>C Y3 >?cif VA AHU 3 ?Beier., 100 0 100 0 0 ' 0 0 0 0 .................::.,, A/C 4* < ': VA ..................:::::. AH U 5 Select Minimum Panel Rating STEP3 Article 220.82 (B) (3) :GAS :..............:;;;,: !!'> 1 Water Heater 1.,800'!A r': 1 Refrigerator ...................:... :;.6W VA w Freezer 0 VA rl 1 Dishwasher W VA '► ::..: 1 Disposal r............... :400 VA ';': 1 Range Hood .General lighting, Sm. Appl. & Laundry QTY Total 1 8,800 VA 1 !! : Heating Load6,000 VA VA 'Qt7 r CU Load y "'7;930 VA VA Qty +r VA : Qty, E' <: Electric Space Heat @ 66% <4; 40% >3, vs. A/C 100% ,........... VA Qt.y :1,200 VA >; 1 Microwave 1,200 VA 1.,45n VA :; Central Vac VA ^ �, `. Demand Load ,170 VA r'R_ 1 Mini Refrig 170 VA v P� 0 ;900 VA +' 1 Compactor Neutral Demand 6,670 V1 Instal Hot I, 00 VA �` (toning Center G, �'` , !® in:ServiceRe If sekR 4 Jacuzzi Tub ❑ select_ Sprinkler Pump . M . Feeder size ❑ select Well Pump GQNS Neutral size select Fountain Pump G�� Grdiing Cond. 8Y select. !!:: Elevator VA_ Pool Equip. Panel16,606 VA ❑ Other load ❑ Other load STEP 4 Article 220.82 (B) (3) Electric Clothes Dryers STEP 5 Article 220.82 (B) (3) Electric Ranges Col C demand 11,700 VA 7,930 VA 22,296 VA VA VA 27,528 VA 115 A 44 A 125 A 2 6 6 ❑ Copper e en Total Appliance Load 22,296 VA 8000 , or Number of appliances . 1 Cooktop Col B demand Qcheck Box for Gas Range Cooktop Col B demand Oven(s) Col B demand Oven(s) Col B demand Number of appliances 0 Dem. Factor Cooktop & Oven Demand Load Pool Panel Feeder Calculation (See Note) Continuous Motors 506 ...... Non -continuous 0 ...... Spa heater 11 kVA 1 ... Pool heater 3.5 ton ' 1 , , , , , , Pool heater 5 ton Pool Light A00 ..... 0 ...... Blower Sete& rs:; 0 11 .240Y other load 0 © 240v other load 0 0 240v 0 Min .Co er Pool,Feeder # 3 AWG Appliance Demand Load VA N 1,800 VA Dryer Demand Load VA 0 1,030 VA Range Demand Load ' 690 VA •::© 240v 400 VA rvice Demand :1,200 VA >; 1 Microwave 1,200 VA 1.,45n VA :; Central Vac VA ^ �, `. Demand Load ,170 VA r'R_ 1 Mini Refrig 170 VA v P� 0 ;900 VA +' 1 Compactor Neutral Demand 6,670 V1 Instal Hot I, 00 VA �` (toning Center G, �'` , !® in:ServiceRe If sekR 4 Jacuzzi Tub ❑ select_ Sprinkler Pump . M . Feeder size ❑ select Well Pump GQNS Neutral size select Fountain Pump G�� Grdiing Cond. 8Y select. !!:: Elevator VA_ Pool Equip. Panel16,606 VA ❑ Other load ❑ Other load STEP 4 Article 220.82 (B) (3) Electric Clothes Dryers STEP 5 Article 220.82 (B) (3) Electric Ranges Col C demand 11,700 VA 7,930 VA 22,296 VA VA VA 27,528 VA 115 A 44 A 125 A 2 6 6 ❑ Copper e en Total Appliance Load 22,296 VA 8000 , or Number of appliances . 1 Cooktop Col B demand Qcheck Box for Gas Range Cooktop Col B demand Oven(s) Col B demand Oven(s) Col B demand Number of appliances 0 Dem. Factor Cooktop & Oven Demand Load Pool Panel Feeder Calculation (See Note) Continuous Motors 506 ...... Non -continuous 0 ...... Spa heater 11 kVA 1 ... Pool heater 3.5 ton ' 1 , , , , , , Pool heater 5 ton Pool Light A00 ..... 0 ...... Blower Sete& rs:; 0 11 .240Y other load 0 © 240v other load 0 0 240v 0 Min .Co er Pool,Feeder # 3 AWG A - B N 506 0 633 0 0 0 6875. 6875 •>❑ 240v .::.. 3125 3125 •::© 240v 0 0 240v 100 0 100 0 0 ' 0 0 0 0 0 0 0 88'A 83 A 5 A Minimum Panel Rating ;. '100A Phase Amperes Neut. load Use this area for your own notes «««««««< Non -continuous Continuous Motors selrU. 1/6 hA ;:::Q 120v select •>❑ 240v .::.. select •::© 240v .................. selerti© 240v .................. select :;: © 240v Non -continuous .Motors selrU. !Y:: ❑ 240v ....................... select ? ❑ 24ov select >< ❑ 240V ..................:::::. Se:ese;ect ??!! ❑ 240v ...........;zzzaz select i!! ❑ 240v 4.2 Motor Neutral Load Max.Unbalanced Neutral Load �AOEDEL W PARKWAY ESPLANADE NORTH FRED WARING DRIVE =VICINITY MAP N.T.S. SHEET INDEX 1. SITE PLAN 2. ONE LINE DIAGRAM 3. RACK MOUNTING DETAIL 4. CONNECTION DETAIL 5. CONNECTION DETAIL ENLARGED APN 609-630-014-9 LEGAL DESCRIPTION RECORDED BOOK/PAGE: MB 372/99 SUBDIVISION NAME: TR. 29323-4 LOT/PARCEL: 14 TRACT NUMBER: 29323 INITIAL RELEASE KOSTELECKY RESIDENCE SOLAR ELECTRIC INSTALLATION 1�UTL� I� I SEP 2 2 2011 a Lo By ri v, o� NOTE: C) ALL CONSTRUCTION SHALL COMPLY WITH THE 2010 CALIFORNIA RESIDENTIAL, MECHANICAL, N JELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL fV 0) DESCRIPTION fwtbft t',v0, 20ti 014 rue f C cS 0-ogti CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION I DATE 1214 ice_ BY—VV--j v M.S KW IV SlS't&LAA eWLI • US SOLAR SOLAR ELECTRIC INSTALLAT APPROVALS DATE TITLE SHEET ap KOSTELECKY RESIDENCE DRA .T. N +- I+ slcnATURE 79_963 PARKWAY ESPLANADE N0R;L s-2+0 OFnCE LA QUINTA, CA 92253 No ECKED B.SLATER REV ACME MWff No O. 2011-0011-00 DO NOT SCALE DRAWINGS—ME "-20' REV. A — 1 w 1 PARKWAY ESPLANADE NORTH I SOLAR ELECTRIC ARRAY 46 230 WATT CANADIAN SOLAR INC. PV MODULES MODEL NO. CS6P-230P 10.6 KW -D¢ SYSTEM RATING (9.3 KW -AC) PROPERTY UNE (APPROX.) DRIVEWAY J #1B4SR-101671 PROPOSED BIDIRECTIONAL METER ii EXISTING 200 AMP ELECTRICAL PANEL NEW UTILITY LOCKABLE AC, DISONNECT DJ AACENT TO MAIN ELECTRICAL PANEL SQUARE D 100 AMP, 240 VAC NON -FUSIBLE, GENERAL DUTY, 2 -POLE MODEL NO. DU323RB SOLAR SUB PANEL ONE POWER -ONE AURORA PVI 6000 AND TWO POWER -ONE AURORA PVI 3000 INVERTERS TO BE LOCATED IN ACCORDANCE WITH OWNER PREFERENCE CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVE® FOR CONSTRUCTION DATE By UN1106005P 100KVA C PHASE HIGH 7.2KV LOW 120/240V 0' 20' 40' ., a M 0 v v CT) 0 04 CV 0) 10.580 WATT DC (9,343 WATT AC) SOLAR ELECTRIC ARRAY 46 CANADIAN SOLAR INC. 230 WATT SO MODEL NO. CS6P-230P INDIVIDUAL MODULE RATING: r -i PTC=211.0 WATTS Voc=36.8 VDC Isc=8.34 AMPS ! � 111111111111 � � 111111111111 _ 2 STRINGS LLLLW�Jp i ^�-{ R 6 MODULES I � I L #10 AWG, THWN-2-- 1 #10 AWG GROUND L_ 2 STRINGS OF i 5 MODULES 4 #10 AWG, THWN-2-- 1 #10 AWG GROUND INVERTER A 11240 120 V I I 1 SQUARE D 100 AMP, I DERATED - 3 I 240 VAC, NON -FUSIBLE, i I TO 150A I /� 140A OE 'GENERAL DUTY, 2 -POLE, NFS iA I I I 1 UTILITY LOCKABLE AC V I 20A 2 -POLE I AC DISCONNECT (1 EA) POWER -ONE AURORA PVI-6000-OUTD-US GRID -TIE INVERTER INPUT: 90 TO 580 VDC OUTPUT: 6000 WATTS MAX 240 VAC, 25 AMPS MAX INTEGRATED GFCI I MODEL NO. DU323RB I I Q3 I 120A ? _?QE I WITHTIN 5' OF METER PANEL T 1 SOLAR SUBPANEL rn AWG, THWN-2- AWG GROUND I I W80A 2 -POLE -2 10 A O A i --� 1 10 A ,� � -- - --- /1 '2 ff 10 AWG, 1 #110 AWG W I NWt1I INVERTERS B & C U N D r w u OR CONSTRUCTION DATE POWER -ONE AURORA PVI-3000-OUTD-US GRID -TIE INVERTER INPUT: 160 TO 530 VDC OUTPUT: 3000 WATTS MAX 240 VAC, 12.5 AMPS MAX INTEGRATED GFCI WIRE AND CONDUIT SCHEDULE AMPS MULTI- PUER �tAJ1�1W� Md ��7 MODULE TO MODULE 8.34 1.56 13.01 NO. 10 USE -2 N/A 2 AWG, THWN-2- #4 AWG, THWN-2 13.01 NO. 10 THWN-2 REV. OESCRIPnoN 8.34 DATE 1 AWG GROUND 1 #4 AWG GROUND 25.00 A INmAL RELEASE 3/4- xx-XX-XX 5 L5 -U 1 THWN- 3_4 SUBPANEL TO AC DISCONNECT 50.00 1.25 I 1 r - - - - - - - EXISTING MAIN #184SR-101671 62.50 1 NO. 4 1 THWN-2 1 1I I LOAD CENTER PROPOSED 10 AWG, THWN-2 i _ _ _ _ _ BIDIRECTIONAL 10 AWG GROUND i F200A �� Q I i 2 200A MAIN , I METER I MLO 1 BREAKER # -- L_ 2 STRINGS OF i 5 MODULES 4 #10 AWG, THWN-2-- 1 #10 AWG GROUND INVERTER A 11240 120 V I I 1 SQUARE D 100 AMP, I DERATED - 3 I 240 VAC, NON -FUSIBLE, i I TO 150A I /� 140A OE 'GENERAL DUTY, 2 -POLE, NFS iA I I I 1 UTILITY LOCKABLE AC V I 20A 2 -POLE I AC DISCONNECT (1 EA) POWER -ONE AURORA PVI-6000-OUTD-US GRID -TIE INVERTER INPUT: 90 TO 580 VDC OUTPUT: 6000 WATTS MAX 240 VAC, 25 AMPS MAX INTEGRATED GFCI I MODEL NO. DU323RB I I Q3 I 120A ? _?QE I WITHTIN 5' OF METER PANEL T 1 SOLAR SUBPANEL rn AWG, THWN-2- AWG GROUND I I W80A 2 -POLE -2 10 A O A i --� 1 10 A ,� � -- - --- /1 '2 ff 10 AWG, 1 #110 AWG W I NWt1I INVERTERS B & C U N D r w u OR CONSTRUCTION DATE POWER -ONE AURORA PVI-3000-OUTD-US GRID -TIE INVERTER INPUT: 160 TO 530 VDC OUTPUT: 3000 WATTS MAX 240 VAC, 12.5 AMPS MAX INTEGRATED GFCI WIRE AND CONDUIT SCHEDULE AMPS MULTI- PUER REQ. WIRE WIRE AMPS GAUGE TYPE CONDUIT SIZE MODULE TO MODULE 8.34 1.56 13.01 NO. 10 USE -2 N/A MODULE TO DC DISCONNECT 8.34 1.56 13.01 NO. 10 THWN-2 3 4' DC DISCONNECT TO INVERTERS 8.34 1.56 13.01 NO. 10 THWN-2 3 4 INVERTER A TO SUBPANEL . 25.00 1.25 31.25 NO. 8 THWN-2 3/4- I R RS C PA 5 L5 -U 1 THWN- 3_4 SUBPANEL TO AC DISCONNECT 50.00 1.25 62.50 NO. 4 1 THWN-2 1 AC DISCONNECT TO MAIN PANEL 150.00 1.25 62.50 1 NO. 4 1 THWN-2 1 UTILITY GRID #UN1106005P 100 KVA C PHASE HIGH 7.2KV LOW 120/240 GROUND BY AMPSCH CIRCUIT X 1.56 - 13.01 AMPS ODULES X 36.8 VOLTS - 441.6 VOLTS DC 441.6 VOLTS DC X 1.12[PER CEC TABLE 690.7] = 94.59 VOLTS 1 STRING = (2) 010 THWN-2 AWG WIRE. (1) 010 THWN-2 GROUND FUSED AT 15 AMPS EACH CIRCUIT LOCATED AT INVERTER 010 WIRE = 40 AMPS X .58[PER CEC TABLE 310.15(8)(2)(c) do PER CEC TABLE 690.31(c)] = 23.20 AMPS = OK AC CIRCUITS 1NVERIER A PVI 6000 TO SUB PANEL 6000 / 240 VOLT = 25A X 1.25 - 31.25A (40 AMP 2 POLE BREAKER) 08 WIRE = 55 AMPS X .76[PER CEC TABLE 690.31(C)] = 41.80 AMPS = OK INVERTERS B do C PVI 3.0 TO SUB PANEL 3000 / 240 VOLT = 12.SA X 1.25 = 15.63A (20 AMP 2 POLE BREAKER) 010 WIRE = 40 AMPS X .76[PER CEC TABLE 690.31(C)] = 23.20 AMPS = OK SUB PANEL TO MAIN ELECTRICAL PANEL 25A + 12.5A + 12.5A - 50A X 1.25 = 62.5A (80 AMP 2 POLE BREAKER) 04 WIRE = 95 AMPS X .76[PER CEC TABLE 690.31(C)] = 72.2 AMPS - OK NOTES: EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH CEC 690. PROVIDE WARNING SIGN PER CEC 690-17 READING "WARNING -ELECTRIC SHOCK HAZARur- DO NOT TOUCH TERMINALS -TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION", AND LABEL IN ACCORDANCE WITH APS REQUIREMENTS. ® LABEL BREAKER "SOLAR ELECTRIC POWER SOURCE" PER CEC 705-10, AND "BREAKERS ARE BACKFED" PER CEC 690-64(b)5. US SOLAR SOLAR ELECTRIC INSTALLATION 4PPROVALS DATE ONE LINE DIAGRAM 4-2z- 1 KOSTELECKY RESIDENCE OFFICE 79-963 PARKWAY ESPLANADE NORTH KED B.SLATER 1 -u OFFICE LA QUINTA, CA 92253 C sm 000E ffmim NO. ORmm N0. A 2011-0011-02 Do NOT SCALE DRAWING SCAU 1'=20' 1 REV. A I94M 1 OF 1 II7:�1i :1ATT PROFESSIONAL SOLAR PRODUCTS ALUMINUM SUPPORT -RAILS, ATTACHED TO QUICK MOUNT PV STANCHIONS. QUICK MOUNT PV STANCHIONS, ATTACHED TO TRUSSES USING Ne" X 3- LAG SCREW CANADIAN SOLAR INC. CS6P-230P a rn 0 v v of 0 Q r (V 0) CANADI CL SEE ENLARGED CONNECTION N4 co 77v v Cn r 0 CV 04 0) REV. DESCRIPTION DATE A INRIAL RELEASE xx-xx-xx 1110, . CANADIAN SOLAR INC. C56P-230P PV MODULE \ S O L AR PANEL PROFESSIONAL SOLAR PRODUCTS 1 1/4- X 5 1/2- ROOF TRAC RAIL KIT I ALUMINUM POST 5/16"-18 X 1' MACHINE BOLT I 5/16- X 3/4" GRADE 8 BOLT I 5/8' PLYWOOD / / 5/16" X 3- LAG BOL US SOLAR SOLAR ELECTRIC INSTALLATION TRUSSES ® 24' ON CENTER APP VALS DATE CONNECTION DETAIL ENLARGED I.T.CRAIN 4-22-11 KOSTELECKY RESIDENCE TURE 79-963 PARKWAY ESPLANADE NORTH ne5�s OMCE LA OUINTA, CA 92253 MECKED B.SLATER REV. ME CODE O/OEIlf 110. I MAM40 NO. A 1 2011-0011-05 DO NOT SCALE DRAWING I SME 1'=20' R EV. A I SHM 1 OF 1 CEC SOLAR LABELS • SECTION 690.53 LISTS THE POSTING REQUIREMENTS: RATED MAXIMUM POWER—POINT CURRENT, RATED MAXIMUM POWER—POINT VOLTAGE, MAXIMUM SYSTEM VOLTAGE, AND SHORT—CIRCUIT CURRENT. • THE AC DISCONNECT — STATING THE RATED AC OUTPUT CURRENT AND NOMINAL OPERATING AC VOLTAGE (AS . STIPULATED BY CEC SECTIONS 690.14[C][2] AND 690.54). • THE DC DISCONNECT, NOTING THAT THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION (CEC 690.17). • AT THE LOCATION OF THE GROUND—FAULT PROTECTION, NORMALLY AT THE INVERTER, WARNING OF A SHOCK HAZARD (CEC 690.5[C]). • WHERE THE SOLAR—ELECTRIC SYSTEM INTERCONNECTS TO THE UTILITY (CEC 690.54). • AT THE LOCATOIN OF THE MAIN SOLAR BREAKER IN THE MAIN SERVICE PANEL (690.64[B](7)). ti ,•z A WARNING PHOTOVOLTAIC AC DISCONNECT ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE UNE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION. OPERATING CURRENT: 8.34 AMPS OPERATING VOLTAGE: 240 VOLTS AC A WARNING PHOTOVOLTAIC DC DISCONNECT ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE UNE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION. OPERATING CURRENT: 8.34 AMPS OPERATING VOLTAGE: 240 VOLTS DC CITY OF LA QUINTA BUILDING & SAFETY DEPT. AV FOR CONSTRUCTION DATE BY WARNING PHOTOVOLTAIC AC CIRCUIT BREAKER SOLAR ELECTRIC POWER SOURCE BREAKERS ARE BACKFED WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED. NORMALLY CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED of No. of DC and AC modules, DC and AC rating Inverter watts of inverters of module efficiency STC calculation system Canadian Solar Inc. 24 230 5326.8 watts 5,520 watts -DC CS6P-230P 211 96.5% 4,887 watts -AC Inverter nameplate Inverter efficiency Power -One Aurora 1 6000 96.5% 230vac Canadian Solar Inc. 12 230 2649.6 watts CS6P-230P 211 96.0% Inverter nameplate Inverter efficiency Power -One Aurora 1 3000 96.0% 230vac DC and AC kW of system 5.5 kW -DC 4.9 MAC 2,760 watts -DC 2.8 kW -DC 2,431 watts -AC 2.4 kW -AC Canadian Solar Inc. 10 230 2208 watts 2,300 watts, DC 2.3 kW -DC CS6P-230P 211 96.0% 2,026 watts -AC 2.0 kW -AC Inverter nameplate Inverter efficiency Power -One Aurora 1 3000 96.0% 230vac Note: total watts -AC of system cannot exceed the total nameplate watt rating of the inverters TOTAL DC WATTS 10184.4 watts 10,580 watts -DC 10.6 kW -DC TOTAL AC WATTS 9,343 watts -AC 9.3 MAC 9/21/2011 Kostelecky - system watt ratings.As WEIGHT LOADING ANALYSIS Solar Electric Installation Kostelecky Residence 79-963 Parkway Esplanade North, La Quinta, CA 92253 Contractor: United States Solar April 22, 2011 Ground Mount Analvsis of dead load weight added by installation of solar arra Canadian Solar Inc. CS6P-230P - solar module weight 44.1 pounds No. of solar modules 50 Total weight of modules 2,205 pounds Weight of each Professional Solar Products "Roof Trac" 18 pounds No. of rack sets 12.5 Total weight of rack sets 225 pounds Total weight of solar array 1 2,430 pounds Height of each module 5.4 feet Width of each module 3.2 feet Area of one module I 17.3 square feet Area of entire solar array 1 864.6 square feet Weight of solar array per unit 2.8 pounds/square foot No. of stanchions connected to rafters with lag screws 1 591 Weight loading per vertical pipe 41.4 pounds/connection See attached sheets for engineering information on the Professioal Solar Products 'Roof -Trac" racks. 9/21/2011 Kostelecky -weight load.xls X I NCI & ASSOCIATES Structural Engineers CLIENT: Professional Solar Products, Inc. 1551 S. Rose Ave., Oxnard, CA 93033 Tel: 805.486-4700 Subject: Static load test results for the following: Mounting System Maximum Frame Maximum Frame Load Equivalent Wind Speed "Professional Solar Prod. Pat 6,360,491" on the Length* (in.) Width On.) 1 Obs/ft2) (mph) RoofTrac ® 65 40 50 125 TEST SETUP (as shown In attached drawing detail): Three modules, as specified above, were bolted to 136"x1.5"x2.5" Professional Solar Products (PSP) patented RoofTrac0 support rails using an assembly of 5/16" Stainless Steel (SS) bolts, SS lock washers and proprietary PSP aluminum clamps and inserts. The RoofTrac® support rail was attached to the PSP RoofTrac® structural attachment device with 3/8" SS hardware at four attachment points. The setup was attached to 2"x6" wooden rafters using 5/16" x 3-1/2" SS lag bolts. The attachment spans consisted of 48" front to rear with structural attachments spaced 72" on center. TEST PROCEDURE (as shown in attached drawingdetail): The test set up was top loaded to 50 Ib/ft2. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. The test setup was then inverted and loaded to simulate the uplift condition. The test set up was re -loaded to 50 Ib/ft2. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. TEST RESULTS: The maximum top load deflection was recorded at 0.313", with no permanent deformation. The maximum uplift deflection was recorded at 0.250", with no permanent deformation. This document certifies the RoofTrac® mounting system used with the modules, as specified above, withstands a 50 Ib/ft2 static pressure load, equivalent to a wind speed of approximately 125 mph' The mounting system performed as expected. Sincerely, James R. Vinci, S.E. This engineering report verifies that Vinci & Associates has provided Independent observation for load testing as described In this report The results of this load test reflect actual deflection values and are generally accepted as the Industry standard for testing module mounting systems. Vinci & Associates does not field check Installations or verify that the mounting system is Installed as described In this engineering report A fr To assist the building inspector In verifying the authenticity or'A Sol this proprietary mounting syIrn assilver reflective "RoofTracm" label, as shown, is placed on at Q" least one of the main suppowith "Professional Solar Prod. Pat 6,360,491" on the Roof Trac underside of rail. Structural attachment: Lag bolt attachment should be installed using the proper pilot hole for optimum strength. A 5/16" lag P� 6.360 bolt requires a 3/16" pilot hole. It Is the responsibility of the installer to insure a proper attachment is made to the structural member of the roof. Failure to securely attach to the roof structure may result In damage to equipment, personal injury or property damage. This office does not express an opinion as to the load bearing characteristics of the structure the mounting system/modules are being Installed on. ICC accredited laboratory tested structural attachments manufactured by Professional Solar Products (Including, but not limited to Fastlacke , TIIeTrac®, and FoamJack®) can be interchanged with this system. Check with local building department or AHJ for site specific requirements. *Modules measuring within stated specifications and tested to UL1703, or equivalent, are Included In this engineering **Wind loading values relative to defined load values using wind load exposure (125 mph for 5/12 roof pitch or less; 100 mph for greater than 5/12 roof pitch) and gust factor coefficient "exposure C" as defined In the 2009(IBC) /203A(CBC) ***Module tested: 64.6" x 39.4" x 1.7" (sln) ****Est. snow load rating of 25 Ib/ft2 based on 2.0 safety factor 31324 VIA COLINAS STE 101 a WESTLAKE VILLAGE, CA 91362 Page 1 of 2 RT6_2011 Module Area = 18 ft2 each I11 72" go I �I Approx 20' max overhang Total module (45 lbs ea.) and rail (12 lbs ea.) weight: 159 lbs Number of attachments: 4 ea Weight / attachment point: 40 lbs Area: 54 ft2 Distributed weight: 2.95 Ib/ ft2 , 5/16" Stainless Steel Hex bolt 5/16" Stainless Steel Lock Washer Aluminum ProSolar I Inter -Module Clamp Aluminum ProSolar �1 Rail nut ! 2-1/2" Aluminum ProSolar Roofrrac®.Support Rail 3/8" Stainless Steel. Hex Bolt and Flat'Washer Aluminum ProSolar patented FastJack® Roof Attachment' 5/16" Stainless Steel Lag Bolt and Flat Washer ao" 2,710 lbs / 50 psf .. Load Deflection: 5° ae" I "I2,7101bs / SO psfI I Up lift Deflection: 0. 'Lab tested structural attachments manufactured by Professional Solar Products RoofTrae- . (including Fastlack® , TileTrac®, and FoamJack®) can be Interchanged with this system. Solar Modules Professional Solar Products RootTrae Patent#6,360,agf Static load test illustration Photovoltaic mounting.system Page 2 of 2 RT6_2011 i t Key Features • Top ranked PVUSA (PTC) rating in California for higher energy production • 6 years product warranty (materials and workmanship); 25 years module power output warranty • Industry leading plus only power tolerance: +5W (+2.1 %) Strong framed module, passing mechanical load test of 5400Pa to withstand heavier snow load • Ultra reliable in corrosive atmosphere, verified by IEC61701 "Salt Mist Corrosion Testing" • The 1 st manufacturer in the PV industry certified for ISO:TS16949 (The automotive quality management system) in module production since 2003 • ISO 17025 qualified manufacturer owned testing lab, fully complying to IEC, TUV, UL testing standards CanadianSolar On -grid Module CS6P is a robust solar module with 60 solar cells. These modules can be used for on -grid solar applications. Our meticulous design and production techniques ensure a high -yield, long-term performance for every module produced. Our rigorous quality control and in-house testing facilities guarantee Canadian Solar's modules meet the highest quality standards possible. Applications • On -grid residential roof -tops • On -grid commercial/industrial roof -tops • Solar power stations • Other on -grid applications Quality Certificates • IEC 61215, IEC 61730, IEC 61701, UL 1703, CEC Listed, CE, KEMCO and MCS • IS09001: 2008: Standards for quality management systems • ISO/TS16949:2009: The automotive quality management system Environment Certificates • IS014001:2004: Standards for Environmental management systems • 00080000 HSPM: The Certification for Hazardous Substances Regulations 'Co-� IEC o®. •Q. E CUB ®fig eV� www.canadiansolar.com CS6P-220/225/230/235/240P F_1VllL; .r rca1 udid CS6P-220P CS6P-225P CS6P-230P CS6P-235P CS6P-240P Nominal Maximum Power at STC (Pmax) 220W 225W 230W 235W 240W Optimum Operating Voltage (Vmp) 29.2V 29AV 29.6V 29.8V 29.9V Optimum Operating Current (Imp) 7.53A 7.65A 7.78A 7.90A 8.03A Open Circuit Voltage (Voc) 36.6V 36.7V 36.8V 36.9V 37.OV Short Circuit Current (Isc) 8.09A 8.19A t 8.34A 8.46A 8.59A Operating Temperature U �' -40C—+85C Maximum System Voltage 1000V (IEC) /600V (UL) Maximum Series Fuse Rating 15A Power Tolerance +5W Temperature Coefficient Pmax -0.43%rC Voc -0.34 VC Isc 0.065 VC NOCT 45C Under Standard Test Conditions (STC) of irradiance of 1000W/m', spectrum AM 1.5 and cell temperature of 25'C Mechanical Data Cell Type Poly -crystalline Cell Arrangement 60 (6 x 10) Dimensions 1638 x 982 x 40mm (64.5 x 38.7 x 1.571n) Weight 20kg (44.1 lbs) Front Cover Tempered glass Frame Material Anodized aluminlum alloy Standard Packaging (Modules per Pallet) 20pcs Engineering Drawings i uiiu�iniu�itnu� imu�ii�u�nnu� UM,INN�ilu''�IIiliuIm I1111�01W1�W1 'Specifications Included in this datasheet are subject to change without prior notice About Canadian Solar IN Curves (CS6P-240P) Canadian Solar Inc. Is one of the world's largest solar Canadian Solar was founded In Canada In 2001 and was companies. As a leading vertically -integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) In manufacturer of Ingots, wafers, cells, solar modules and November 2008. Canadian Solar has expanded Its cell capacity to solar systems. Canadian Solar dalliers solar power products of uncompromising quality to worldwide 80OMW and module capacity to 1.3GW In 2010. customers. Canadian Solar's world class team of professionals works closely with our customers to provide them with solutions for all their solar needs. 7 4 $ i U �' A 0' 5 to 1$ 20 25 $o 36 43 p 5 30 15 20 25 30 3S 40 46 Voli3je(v� voua�e(vj Canadian Solar Inc. Is one of the world's largest solar Canadian Solar was founded In Canada In 2001 and was companies. As a leading vertically -integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) In manufacturer of Ingots, wafers, cells, solar modules and November 2008. Canadian Solar has expanded Its cell capacity to solar systems. Canadian Solar dalliers solar power products of uncompromising quality to worldwide 80OMW and module capacity to 1.3GW In 2010. customers. Canadian Solar's world class team of professionals works closely with our customers to provide them with solutions for all their solar needs. Roof Trac TM Patent #6,360,491 The Original "Top -Down" PN Mounting System. Illustrated above is how the Tile poem attachment seamlessly integrates with the Roof ftc- mounting system. Integrated with Tile Trac' attachments The patented Roof D-ac'",q)stem installed with the Tile Trac allachmcna method provides an ideal solution for mounting on a No roof, Tile 7tac® reduces the possibility of broken tiles and leaking roofs, allowing the installer to make structural attachments to the roof raflo: The Roof Trac' installed with the Tile Trac® allows solar support rails ,,.,to be adjusted to compensate for uneven roof's, f�. The 711e ftc® attachment system is the perfect base for surface mounting on cwnposition roofs! It has over 10 sq. inches of base to prevent damaging delicate composition shingles. Patented Slide -N -Clamp proressionai SOLAR products Roof Trac® & Fest Jack` protected under Patent #6,360,491 & Other patents pendl Tile Trace protected under Patent #8,646, The Roof ftc` support rail was designed to conceal all attachment hardware. All connections are made inside the support rail bidden from view. All eaposed aluminum is fully anodized to module manufacturer specifications. Fully integrated, and patented, clamping system actually changes the structural properties of the aluminum channel making it significantly stronger. This design allows solar modules to be installed at a lower profile to the roof providing a more aesthetically pleasing installation. Module clamps are specifically designed, extruded and engineered for each specific module frame. Our innovative clamping system provides inward tension on the module frame securing the laminate in the frame. uick Mount DY Your'Solution in Mounting Products Solar ® H2O ® Conduit m HVAC 0 Custom Curved Tile Mount Specifications All Patents Pending 5/16"-18 x 1"Machine Bolt (Stainless Steel ) For Rack Attachment 5/16" Split Lock Washer (Stainless Steel) (Not a theft -prevention feat Racking of Choice (Not Included) w r.:::... 5/16" ID Fender Washer (Stainless Steel) (E) 18"x 18" Curved -Tile 5/16"-181D x 1 1/4"OD Sealing Washer (Stainless Steel) EPDM Rubber Counter Flashing Field Applied Appropriate Sealant Flexible Aluminum Flashing 1 1/4"x 5 1/2"Aluminum Post Cut Tile S/16"x 3/4" Grade8 Bolt Cast Aluminu Base a e Peel and Stic Flashing -Under paper above - � -_ _-. I - - (E)Batton Installation Tools Required: . (E) Plywood Sheathing Tape Measure I Drill with 1/4"wood bit (E) Tar Paper Ratchet w/ 1/2" Socket 6" Caulking Gun Lip of Tile to 1 Tube of Appropriate Sealant Center ofPost (E) 2 x Rafters 30 Ib felt paper Wisk Broom /Vacuum 2 each 5/16"x 3" Lag Bolts Roofers Bar /Shingle Ripper Lag Bolt Specifications Specific 5/16 shaft 5/16 shaft gravity 3" thread depth 1" thread depth Douglas Fir, Larch .50 798 Z66 Douglas Fir, South .46 705 235 Engelmann Spruce (MSR 1650 f & higher) .46 705 235 Hem, Fir .43 636 212 Hem, Fir. (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir .42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources: Uniform Building Code; American Wood Council Notes: 1) Thread must be embedded In a rafter or other structural roof member. 2) Pull-out values incorporate a 1.6 safety factor recommended by the American Wood Council. 3) See UBC for required edge distances. "Note: To maintain waterproofing of substrate it is important to make sure the Peel and Stick Flashing is property placed over the Mount Base, and under the course of paper above. If the paper above does not reach due to layout, place.an additional piece of roofing paper over the Peel and Stick and under the next course of paper above. (See instructions page 4) v Changing the Shope of Power General Specifications Outdoor Models PUI-3.0-OUTD-US / PVI-3.0-OUTD-S-US PUI-3.6-OUTD-US / PVI-3.6-OUTD-S-US PUI-4.2-OUTD-US / PUI-4.2-OUTD-S-US High -Efficiency, 3 kW to 4.2 kW Inverters Aurora® grid -tie transformerless inverters offer a unique combination of ultra-high efficiencies, installer -friendly designs, long service life, and competitive initial acquisition costs; significantly increasing return on investment in solar -power installations. Industry -Leading Features and Performance • High efficiencies deliver more energy— up to 96.8% (96% CEC). • Two inputs with independent MPPTs, optimize power from multiple arrays oriented in different directions. • Compact size and high power density: 460OW max of output power in a box size of just 3311/16" x 1213/16" x 81/4". Unmatched Applications Flexibility • Full -rated power available up to 50 °C ambient temperature. • Two input sections, with parallel option, with independent high-speed MPPTs, optimize energy harvesting from multiple arrays oriented in different directions. • Wide MPPT operating range: 90 to 580 VDC. Field -Proven Reliability • I P65 (NEMA 4) rated enclosure withstands the harshest environmental conditions. • Front -mounted heat sink resists contamination, enhancing cooling and increasing reliability and long-term efficiency. • Grid -connected operation according to international standards, UL1741/IEEE1547 & CSA -C22.2 N.107.1-01. • 10 -year warranty, optionally extendable to 15 and 20 years. AURORA., Photovoltaic Inverters. Installer Friendly • Reverse -polarity protection minimizes potential damage caused by miswiring during installation. • Front -panel mounted LCD display provides real-time updates for all critical operating parameters. • RS -485 and USB communications interfaces. • Integrated DC switch available in compliance with NEC Standard, Article 690 "Solar Photovoltaic System" (USA). • Anti-islanding protection. Models Power PVI-3.0-OUTD-US 3000 W I; PVI-3.6-OUTD-S-US 3600 W PVI-4.2-OUTD-US 4200 W PVI-3.0-OUTD-S-US 3000 W PVI-3.6-OUTD-US 3600 W PVI-3.6-OUTD-S-US 3600 W PVI-4.2-OUTD-US 4200 W PVI-4.2-OUTD-S-US 4200 W a, AURORA® Communicator software simplifies monitoring via PC. AURORA® Easy Control datalogger is available for remote control via Internet or modem. Renewable Energy Division Wet -Me �6 Changing the Shape of Power • si•3w\&3urNss mt . ...�','�.� '.:.d'�lsns��-'. INPUT PARAMETERS': DC Side der " Y � ° ¢�DO NorriinaltDClPower"MV 3120 W 3750 W 8 Tot'aHMO, 0T 3500 W 4:150M 4820 W 04' er'atin 1MP-,P,TOIn ut Volta e1Ran e 90.V to 580 V`" 360Vnominal FuIlzPower MRPT�Range� � 160 V to 530 V ; 200V to 530 V ®:V rid 277. V. 200 V to 530 V ® V rid 277 V 200 V to 530 V @V Yid240kV I 200 V to 530 V @ V rid 240 V 1 220 V to 530 V @ ;V . rid 208 V 1 220 V to 530 V ®V rid 208 V Max In ut'Nit– e AMU 600:V Activation%Volta'"ems 200 V nominal ad'ustable from 120 V to 350 V Numberaof=Inde` eridONMPPjVChannelOW M64YQ'.R&W-6 70 hl.EachIMP. PVC hannel ME 2000 W `.3000 W 3000 W Max MCurr'entlPer7MPP- CK'Cn –n6l KONWOMM 10A 12.5A short circuit 16A 20A short circuit ircuit4 16A 20A short circuit)- 4.' DC?Switcf Irate rated in the: -S versions ratio 600V/25A DC Connections 4:(2 positive; 2 negative) Screw Terminal Block Wire si2es : Solid;: from, AWG20 to AWG'6 - Stranded, from AWG20 to AWG 9 Cable Gland: M25 -Cable diameter. 3/8- to 11/16" OUTP.UT�PARAMETERS' AC.Side,`t' NominahAGPowe7�e'-�1�,��. 3000 W 3600:W 4200 W MMACkPowei� � � � 3300 W 4000':W 4600 W ACtGridGonnection split Phase.240V - sin le Phase 208V/277V NominalACUolta –ems `��"� Default 240V:-`0 tional 208V or 277V(setting re wired ACUoIta R 277 V4244-304). :r °' 240 V,(211-264) 208 V 183-228 NominalACtFre uenc: his' i7t� 60'Hz"' :. Continous ACxOut ut Cur"r`ent ` _ 12A 14.5A - %5=:T -. I 6 .- 17.2 1 20A - 20A - 20A Mazim`u"mt0ut uttOCtP.,'rotection��� 15A - 20A. -:--20A. --16A I 15A.'!! `.20A - 25A I 25A - 25A 25A ACfSide Varistor� �� � 2 live=netrual live -PEI �F ; AC Connecbonn �° .' 7.fr. •_ . _ ;Screw`Terminal`Block Wire sizes :Solid; from, AWG20 to•AWG 6`= Stranded,.from AWG20 to AWG 8 Cable Gland: M25 = Cable diameter, A!' to 11/16" 119 e 05we"rFactor "° >` � rMM1 AC < 2% at rated riower with sine wave ..voltage CEVEfficienc"- NW r Ki ! :. 96% FeedlinPowe�Th�eshold ", ff 20 W Ni" -I ttifiTeT <2W NO transformerless to olo ENVIRONMENTAPARAMETERS .��ta u1 ` Natural cooling A" ibientOTem I'Ran"e'-CIMONOMMENTONOM -25°Cto+60°Cont ut owetderatin�forTamb>55'C I •25°Cto+60°Cderallo forTamb>45°C 0 eratin" Altitude 's 6 000:ft Acoustical'sNoise ?moi `� < 50.'dBA ®.1 m EnvironmentaldNEMA Ratio r NEMA U Relative Hi midi `' I0-100% condensin MECHANICAL��"."asi Dimensions (HzWxD) [inches]. -S version 3311/16° x 1213/16' x 81/4" basic version : 21.1/2" x 1213/16. x 81/4" 37.5:lbs 46:25 lbs OTHER Dis"`la ' NES'(Alpha umerid2 lines Communication RS485 (spring terminal block-.0e,,cross s'ectlon: AWG28-16) USB`connection (for SerVlce only) "Aurore-Easy Control" system for remote control Optlonal Standards and Codes Aurora® Inverters comply with standards set for grid -tied operation, safety,4nd electtomagnetic,compatibility Including. U1.1 741 /IEEE1547 & CSA -C22,2 N.107.1.01, VDE0126, CEI11-20, DK5940, CE164-8, IEC 61683, IEC 61727, EN50081,.EN50082; EN61000; CE certificatlon, EI Real Decreto RD1663/2000 de EspaSa, Changing the Shope of Power General Specifications Outdoor Models PVI-5000-OUTD-US PVI-6000-OUTD-US High -Efficiency, 5kW to 6kW Inverters Aurora® grid -tie transformerless inverters offer a unique combination of ultra-high efficiencies, installer -friendly designs, long service life, and competitive initial acquisition costs; significantly increasing return on investment in solar -power installations. Industry -Leading Features and Performance • High efficiencies deliver more energy— up to 97% (96,5 CEC). • Two inputs with independent MPPTs, optimize power from multiple arrays oriented in different directions. • Compact size and high power density: 6000W max of output power in a box just 38 5/8" x 1213/16 x 711/16" Unmatched Applications Flexibility • Full -rated power available up to 50°C ambient temperature. • Dual input sections with parallel option, with independent high-speed MPPTs, optimize energy harvesting from multiple arrays oriented in different directions. • Wide MPPT operating range: 90 to 58OVDC Field -Proven Reliability • IP65 (NEMA 4) rated enclosure withstands the harshest environmental conditions. • Front -mounted heat sink resists contamination, enhancing cooling and increasing reliability and long-term efficiency. • Grid -connected operation according to international standards, UL1741/IEEE1547 & CSA -C22.2 N.107.1-01 • Ten-year warranty, optionally extendable to fifteen and twenty years. Installer Friendly AURORA -.- Photovoltaic Inverter . • Reverse -polarity protection minimizes potential damage caused by miswiring during installation. • Front -panel mounted LCD display provides real-time updates for all critical operating parameters. • RS -485 and USB communications interfaces. • Integrated DC switch available in compliance with NEC Standard, Article 690 "Solar Photovoltaic System" (USA) • Anti-islanding protection i� MOWN PVI-5000-OUTD 5kW PVI-6000-OUTD 6kW Aurora Communicator software simplifies monitoring via PC. Aurora Easy Control clatalogger is available for remote control via Internet, modem or GSM ine ..)iiupq ui rumv w K' to 3 R A oltaic Inverter I. � INPUT�PARAMETERS, DC:fiSid`e),V,R��� •. iie e e ,iii e� e NominaltDC Po"wer kV1/�s�� 5:15 6::18 Total$MazR ce ommended;DC,Power� kVil z 5.3 6.4 0" e�atin tMPP,�T�In utxVolta eRan e'� .V, ���._� 901 0 580' 360 nominal Full tPower�MPP,aTjR'04e6T[ W. � RIMEM, . 140-530170 530 W -01n 060610 611A, 600 Activation Volta es , ,� 200 nominal ad'ustable within 120-350 4o1"Oflnd9p6rWffPMRWiTrackers 901' 2 Max In utzFowerfEachTMPPdTd k -, -WOMMINAM 4 , 4 N816f uts �` h a � �� 2 1•each MPPT 2 1each MPPT MaxDCtCu�rentEaclMPPT, A 18 22 short circuit 18 22 short circuit T.he mallProtectedlDCfSideUanstor� 4 2 for each MPPT bite rated Ratin :60OVdc/25A n DC Connections 4 (2 POSITIVE, 2 NEGATIVE) SCREW TERMINAL BLOCK 3 KNOCK -OUTS: G1&1/2"'or_G1" (using ring reduction) CONDUCTOR CROSS SECTION :'MAX AWG4 OUTPUT PARAMETERSy ACISide � z Norriinal9GPower k : ,'1' -5000 6000 MWAGIPow,®"r kW WWW `5000 6000 AC G'rid.Connectiori singlephase./ split phase Nom'inaWACWolta a Ran a AW& Default: 240V s lit: hase Optional : 208 or 277 single Iphase(setting required) Ma FUffiSAC Volta epRan a V, .. 1872-224.6 216-259.2: 249.3-299.2 NominalAGF[e "ienc [Hil0 r� 60 Max"AGLineCurrent'A 24.20m18. 30 short circuit 29.25.21.6 30 short circuit AC S de Uaristor NWAW, 2 Live - Neutral [Live - PE AG Connection 5,:<� SCREW TERMINAL BLOCK 3 KNOCK -OUTS: G1&1/2" or G1" (using ring reduction) CONDUCTOR CROSS SECTION: AWG4/8 Lii'mP. werg.Factor6DiX AL 1 ACTCur–rd Wistorti TH RAD W A 0 VAM, <2% at rated- ower with sine wave voltage WalEfficienc . 1 97% CEC Efficienc `��� 96.5% Fee"dlnPowerThre"s`holtlWN20 Ni'"htTmeConsum tion , <2 Isolations 3 Transformer -less ENVIRONMENTALIARAMETERS r Coolie � i �� Y } Natural.coolin ' Am6i9nZCr6 ? Ran a °C 1a� -25 / + 60 out ut power derating above 50°C 0 er`atin tAltitiitle� ft �a�-�`���.���" 6:000 "� AcousUcaitNoise9 dB"A4�� < 50 1 mt Envi'ronmentalIPRatin IP65 Relati 61Hu I8' � `�� ' "' �I 0-100% condensing MECHANICAL .. `.` t wi IY Dimensions Hx1NxD Inches . , `4 38 5/8" x 12:13/16" x 7 11/16" 1IVei' ltx lbs�e'f�m� '66 OTHER Y w Dig laM."1,' YES (Alphanumeric 2 lines Communication' ° RS485 (Spring•terminal block -Conductor cro..ss section: 0,08-1,5mmq/AWG28-16) USB connection:(Service)" "Aurora,Eas -Control" s stem for remote control. (Optional) Standards and Codes Aurora inverters comply with standards set for g rid-tie6 operation, safety, and electromagnetic compatibility including: U1-1741/IEEE1547 & CSA -1322.2 N.107.1-01, VDE0126, CEI 11-20, DK5940, CE164-8, IEC 61683, IEC 61727, EN51)081, EN50082;,EN61000, CE. certification, EI Real Decreto RD1663/2000 de Espa5a, Bin # City of La. Quinta Building 81' Safety Division P.O. Box. 1504., 78-495 Calle Tampico La Quinti, CA 92253— (760) 777-7012 Building Permit Application and .Tracking Sheet Permit A Project Address: %r/ e Lc l4 Owner's Name: �� O l A. P. Number: Address: 7?- X163 Legal Description: City' ST, Zip: Contractor. ep 7� `J y� ����o �:%�z�:a"»r>?saz:�� Tel hone: #.ys�.k ..::•st�"cnr : Address: 7 % 770 F.p j; Project Description: �41g,-1 PV 6 j4, City, ST, Zip: Telephone: 76a _ a is �1 ; ! City Lic. 7s N3 1 Z State Lic. #:,� s—p/�jlp Arch., Engr., Designer: Address: pyt �/ Z► t• t� '7 City, ST, Zip: . Telephone:;•;, . -� °' ns, `` . �-�.�5. .r::z-•��. •zr^> v! .:fY Construction T an Type: Occupancy: pro circle one): New Add'n Alter „Re air Demo Sq. Ft.: # Stories: "' # Units: State Lic. #: Name of Contact Person:. G+�+ Telephone # of Contact Person: 7 7r -, 1/4, Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd' TRACIONG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person '` Plan Check Balance �• Title 24 Calcs. Plans picked up Constraction Flood plain plan Plans resubmitted "1 Mechanical .r— Grading plan 2'! Review, ready for correctionsJUsue r Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plaits resubmitted Grading IN HOUSE:- Review, ready for correctionsfissue + Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 4 Jua � a& 1oJL4r)VtJ— e-OLA4 A T be ��r saQPG., Rtr+fl to �aJ tp - (q0 it. 96) , 1�,610 pt4 -A r 10 �40). 6.0 PARKWAY ESPLANADE NORTH I SOLAR ELECTRIC ARRAY 48 230 WATT YINGU SOLAR PV MODULES MODEL NO. YL230P-298 11. KW -DC SYSTEM RATING (9.4 KW -AC) DRIVEWAY #1 B4SR-1 PROPOSED BIDIRECTIO METERI - DATE 111 01 �LDLI BY l(I�_ I QN*Qft 1 I - 4491W .F itjvwdK. s BEXSTING 25 AMP ELE' CTRICAL2PANELL �A"1rtg;3 &A�` • "—NEW UTILITY LOCKABLE AC DISONNECT ADJACENT TO MAIN ELECTRICAL PANEL SQUARE D 60 AMP, 240 VAC NON -FUSIBLE, GENERAL DUTY, 2 -POLE \ MODEL NO. DU222RB `SOLAR SUB PANEL DESCRIPTION INITIAL RELEASE ' 1 UN1106005P OOKVA C PHASE CITY O LA QUINTA IGH 7. ow 12o/20/2 40v -BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION 671 TWO FRONIUS IG 5100 INVERTERS TO BE LOCATED IN ACCORDANCE WITH OWNER PREFERENCE . PROPERTY UNE (APPROX.) 2011-11-18 US SOLAR APPROVALS DATE DRAWN I.T.CRAIN 4-22-11 SIGNATURE (760) 766-2408 OFFICE CHECKED B.SLATER REV. DO NOT SCALE DRAWING av SOLAR ELECTRIC INSTALLA SITE PLAN KOSTELECKY RESIDENCE 79-963 PARKWAY ESPLANADE NOR LA QUINTA, CA 92253 . CODE ■Aoir NO. I OPAW C NO. A 2011 —0011-0411111111111111' WALE 1•=20- REV. A — 1 - 1 11,040 WATT DC (9,441 WATT AC) 2 #10 AWG, THWN-2 -, 2 #6 AWG, THWN-2 -i REv' A INITIAL RELEASE SOLAR ELECTRIC ARRAY 1 #10 AWG GROUND i 1 #6 AWG GROUND I _ _ I r �- 48 YINGLI SOLAR 230 WATT SOLAR MODULES i I MODEL NO. YL230P-29B I I I I INDIVIDUAL MODULE RATING: r-4 10 AWG, THWN-2T; INVERTERS TO SUBPANEL 21.25 1.25 PTC=206.6 WATTS i 1 10 AWG GROUND 1125A MLO 4 50 Voc=33.8 VDC 240 120 V 1 AC DISCONNECT TO MAIN PANEL Isc=6.81 AMPS i I I SQUARE D 60 AMP, " DC ��� 3 I 240 VAC, NON -FUSIBLE LE 2 STRINGS OF101111111GENERAL 2 -POLE h DUTY, 2 -POLE, N FSI30A 12 MODULES UTILITY LOCKABLE I Ac AC DISCONNECT (1 EA) MODEL NO. DU222RB oc �30�A2-POLE ----JWITHTIN 5' OF METER PANELTR SUBPANEL AC L 2 STRINGS OF I ' 12 MODULES i FRONIUS IG 5100 1 I 2 #6 AWG, THWN-2 ---J 4 #10 AWG, THWN-2 -J GRID -TIE INVERTERS I 1 #6 AWG GROUND 1 #10 AWG GROUND INPUT: 150 TO 450 VDC i 1 #8 AWG GROUND -7 OUTPUT: 5100 WATTS MAX 240 VAC, 21.25 AMPS MAXI INTEGRATED GFCI CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY L-2 #10 AWG, THWN-2 1 10 AWG GROUND WIRE AND CONDUIT SCHEDULE AMPS MULTI- PLIER REQ. WIRE WIRE AMPS GAUGE TYPE CONDUIT SIZE MODULE TO MODULE 8.34 1.56 13.01 N0. 10 USE -2 N/A MODULE TO DC DISCONNECT 8.34 1.56 13.01 NO. 10 THWN-2 34' DC DISCONNECT TO INVERTERS 8.34 1.56 13.01 NO. 10 THWN-2 3 4 INVERTERS TO SUBPANEL 21.25 1.25 26.56 NO. 10 THWN-2 3/4' P TODISCONNECT 4 50 1,25 N 6 W- 1 AC DISCONNECT TO MAIN PANEL 42.50 1.25 53.13 N0. 6 THWN-2 " DESCRIPnON I DATE .. xx-xx-x1 EXISTING MAIN #184SR-10167'1 LOAD CENTER PROPOSED BIDIRECTIONAL 225A MAIN i METER BREAKER #--- DERATED I - - I TO 175A I / I Q3 I I I I I 60A 2 -POLE UTILITY GRID L- - - - - -- #bN1106005P 10Q KVA C PHASE .mHIGH 7.2KV'_ LOW 120/240. GROUND' o 6.8 1 AMPS EACH CIRCUIT X 1.56 = 10.62 AMPS VOLTAGE DC - 12 MODULES X 33.8 VOLTS - 405.6 VOLTS DC 405.6 VOLTS DC X 1.14[PER CEC TABLE 690.7] = 462.38 VOLTS I STRING = (2) X110 THWN-2 AWG WIRE, (1) #10 THWN-2 GROUND FUSED AT 15 AMPS EACH CIRCUIT LOCATED AT INVERTER #10 WIRE = 40 AMPS X .58[PER CEC TABLE 310.15(8)(2)(c) & PER CEC TABLE 690.31(c)] = 23.20 AMPS = OK AC CIRCUITS + INVERTER TO SUB PANEL 5100 / 240 VOLT - 21.25A X 1.25 = 26.56A (30 AMP 2 POLE BREAKER) /10 WIRE = 40 AMPS X .76[PER CEC TABLE 690.31(C)] = 30.40 AMPS = OK av SUB PANEL TO MAIN ELECTRICAL PANEL , 21.25A + 21.25A= 42.50A X 1.25 = 53.13A (60 AMP 2 POLE BREAKER) #6 WIRE = 75 AMPS X .76[PER CEC TABLE 690.31(C)] = 57 MAPS = OK NOTES: EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH CEC 690. PROVIDE WARNING SIGN PER CEC 690-17 READING "WARNING -ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS -TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION", AND LABEL IN ACCORDANCE WITH CEC REQUIREMENTS. ® LABEL BREAKER "SOLAR ELECTRIC POWER SOURCE" PER CEC 705-10, AND "BREAKERS ARE BACKFED" PER CEC 690-64(b)5. 2011-11-18 Connection (continued) o Equipment ground �0 _ (3) AC -disconnect n� - 0. DC -disconnect z 0 DG -terminal block D> 0° < -71 M O C. O z z -� The next figure shows the'connection area'of the FRONIUS IG. The white plastic divider that separatesihe,AC`from the DC connection area is not shown in the figure. (1) Equipment ground (2) . N - (Neutral) terminal (3) AC -disconnect (4) ' DC -disconnect (5) DG -terminal block 52 (6) PV frame ground (7) Grounding electrode terminal A (8) GFDI fus� PROFESSIONAL SOLAR PRODUCTS ALUMINUM SUPPORT RAILS. ATTACHED TO QUICK MOUNT PV STANCHIONS. QUICK MOUNT PV STANCHIONS. ATTACHED TO TRUSSES USING %5, X 3- LAG SCREW YINGLI SOLAR YL23OP-296 SEE ENLARGED CONNECTION SOLAR PANEL 5/8' PLYWOOD 5/16" X 3' LAG BOLT ALUMINUM BASE TRUSSES 0 24' ON YINGLI SOLAR YL23DP-29B PV MODULE \ PROFESSIONAL SOLAR PRODUCTS I ROOF TRAC RAIL KR THREADED STUD I CEC SOLAR LABELS • SECTION 690.53 LISTS THE POSTING REQUIREMENTS: RATED MAXIMUM POWER -POINT CURRENT, RATED MAXIMUM POWER -POINT VOLTAGE, MAXIMUM SYSTEM VOLTAGE, AND SHORT-CIRCUIT CURRENT. • THE AC DISCONNECT - STATING THE RATED AC OUTPUT CURRENT AND NOMINAL OPERATING AC VOLTAGE (AS STIPULATED BY CEC SECTIONS 690.14[C][2] AND 690.54). • THE DC DISCONNECT, NOTING THAT THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION (CEC 690.17). • AT THE LOCATION OF THE GROUND -FAULT PROTECTION, NORMALLY AT THE INVERTER, WARNING OF A SHOCK HAZARD (CEC 690.5[C]). • WHERE THE SOLAR -ELECTRIC SYSTEM INTERCONNECTS TO THE UTILITY (CEC 690.54). • AT THE LOCATOIN OF THE MAIN SOLAR BREAKER IN THE MAIN SERVICE PANEL (690.64[B](7)). CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPR®IV E® FOR CONSTRUCTION DATE BY Z2 WARNING PHOTOVOLTAIC AC DISCONNECT ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION. OPERATING CURRENT: 8.34 AMPS OPERATING VOLTAGE: 240 VOLTS AC WARNING PHOTOVOLTAIC DC DISCONNECT ELECTRIC SHOCK HAZARD. 00 NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION. OPERATING CURRENT: 8.34 AMPS OPERATING VOLTAGE: 240 VOLTS DC L� WARNING PHOTOVOLTAIC AC CIRCUIT BREAKER SOLAR ELECTRIC POWER SOURCE BREAKERS ARE BACKFED L� WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED. NORMALLY CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED WEIGHT LOADING ANALYSIS Solar Electric Installation Kostelecky Residence 79-963 Parkway Esplanade North, La Quinta, CA 92253 Contractor: United States Solar April 22, 2011 Ground Mount Canadian Solar Inc. CS6P-230P - solar module weight 44.1 pounds No. of solar modules 48 Total weight of modules 2,117 pounds Weight of each Professional Solar Products "Roof Trac" 18 pounds No. of rack sets 12.0 Total weight of rack sets 216 pounds Total weight of solar array 1 2,333 pounds Height of each module Width of each module Area of one module I 17.3 square feet Area of entire solar array 1 830.0 square feet Weight of solar array per unitounds/square foot No. of stanchions connected to rafters with lag screws 1 56 Weight loading per vertical pipe 41. ounds/connection See attached sheets for engineering information on the Professioal Solar Products 'Roof -Trac" racks. 11/17/2011 Kostelecky - weight load.xls No. of DC and AC DC and AC modules, DC and AC rating Inverter watts of kW of inverters of module efficiency 5TG calculation system system ilar 24 230 5255.04 watts 5,520 watts -DC 5.5kWDC 29b 206.6 95.2% 4,720 watts -AC 4.7 kW -AC Inverter namgpiate Inverter efficiency IG 5100 1 5100. 95.2% 230vac in Iii Solar 24 230 5255.04 watts 5,520 watts -DC 5.5 kW -DC I -23012-29b 206.6 95.2% 4,720 watts -AC 4.TkW-AC Inverter nameplate Inverter efficiency s F'ronius IG 5100 1 5100 95.2% 230vac. I Note: total watts -AC of system cannot exceed the total nameplate watt rating of the inverters TOTAL DC WATTS 10510.08 watts TOTAL AC WATTS 11/17/2011 Kostelecky - system watt ratings.As 11,040 watts -DC 11.0 kW DC 9,441 watts -AC 9.4 kW -AC V I NCI & ASSOCIATES Structural Engineers CLIENT: Professional Solar Products, Inc. 1551 S. Rose Ave., Oxnard, CA 93033 Tel: 805.486.4700 Subject: Static load test results for the following: TEST SETUP (as shown in attached drawing detail): Three modules, as specified above, were bolted to 136 x1.5"x2.5" Professional Solar Products (PSP) patented RoofTrac® support rails using an assembly of 5/16" Stainless Steel (SS) bolts, SS lock washers and proprietary PSP aluminum clamps and inserts. The RoofTrac® support rail was attached to the PSP RoofTrac® structural attachment device with 3/8" SS hardware at four attachment points. The setup was attached to 2"x6" wooden rafters using 5/16" x 3-1/2" SS lag bolts. The attachment spans consisted of 48" front to rear with structural attachments spaced 72" on center. TEST PROCEDURE (as shown in attached drawing detail): The test set up was top loaded to 50 Ib/ftz. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. The test setup was then inverted and loaded to simulate the uplift condition. The test set up was re -loaded to 50 Ib/ft2. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. TEST RESULTS: The maximum top load deflection was recorded at 0.313", with no permanent deformation. The maximum uplift deflection was recorded at 0.250", with no permanent deformation. This document certifies the RoofTrac® mounting system used with the modules, as specified above, withstands a 50 Ib/ft2 static pressure load, equivalent to a wind speed of approximately 125 mph*". The mounting system performed as expected. Sincerely, James R. Vinci, S.E. This engineering report verifies that Vinci & Associates has provided Independent observation for load testing as described In this report. The results of this load test reflect actual deflection values and are generally accepted as the Industry standard for testing module mounting systems. Vinci & Associates does not field check Installations or verify thatthe mounting system is Installed as described In this engineering report. A To assist the building Inspector In verifying the authenticity of �v�r this proprietary mounting s:al a pe nen ad es' silver reflective "RoofTracm" label, as shown, Is placed on at least one of the main supps or p an n pwith "Professional Solar Prod. Pat 6,360,491" on the /f Tracunderside of rail. Structural attachment Lag bolt attachment should be Installedusing the proper pilot hole for optimum strength, A 5/16" lag qq 6.36t1Aetbolt requires a 3/16" pilot hole. It Is the responsibility of the Installer to Insure a proper attachment Is made to the structural member of the roof. Failure to securely attach to the roof structure may result In damage to equlpment personal Injury or property damage. ES / This office does not express an opinion as to the load bearing characteristics of the structure the mounting system/modules are being Installed on. ICC accredited laboratory tested structural attachments manufactured by Professional Solar Products (including, but not limited to Fastlackc , TIIeTracG, and Foamlacke) can be Interchanged with this system. Check with local building department or AHJ for site specific requirements. *Modules measuring within stated specifications and tested to 1.11-1703, or equivalent are Included In this engineering **Wind loading values relative to defined load values using wind load exposure (125 mph for 5/12 roof pitch or less; 100 mph for greater than 5/12 roof pitch) and gust factor coefficient "exposure C" as defined In the 2009(IBC) /2010(CBC) ***Module tested: 64.6" x 39.4" x 1.7" (sln) ****Est snow load rating of 25lb/ft2 based on 2.0 safety factor 31324 VIA COLINAS STE 101 " WESTLAKE VILLAGE, CA 91362 Page 1 of 2 RT6 2011 Maximum Frame Maximum Frame Load Equivalent Win d Speed Mounting System 1 Length On.) Width On.) (lbs/ft) (mph) RoofTrac ® 65 40 50 125 TEST SETUP (as shown in attached drawing detail): Three modules, as specified above, were bolted to 136 x1.5"x2.5" Professional Solar Products (PSP) patented RoofTrac® support rails using an assembly of 5/16" Stainless Steel (SS) bolts, SS lock washers and proprietary PSP aluminum clamps and inserts. The RoofTrac® support rail was attached to the PSP RoofTrac® structural attachment device with 3/8" SS hardware at four attachment points. The setup was attached to 2"x6" wooden rafters using 5/16" x 3-1/2" SS lag bolts. The attachment spans consisted of 48" front to rear with structural attachments spaced 72" on center. TEST PROCEDURE (as shown in attached drawing detail): The test set up was top loaded to 50 Ib/ftz. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. The test setup was then inverted and loaded to simulate the uplift condition. The test set up was re -loaded to 50 Ib/ft2. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. TEST RESULTS: The maximum top load deflection was recorded at 0.313", with no permanent deformation. The maximum uplift deflection was recorded at 0.250", with no permanent deformation. This document certifies the RoofTrac® mounting system used with the modules, as specified above, withstands a 50 Ib/ft2 static pressure load, equivalent to a wind speed of approximately 125 mph*". The mounting system performed as expected. Sincerely, James R. Vinci, S.E. This engineering report verifies that Vinci & Associates has provided Independent observation for load testing as described In this report. The results of this load test reflect actual deflection values and are generally accepted as the Industry standard for testing module mounting systems. Vinci & Associates does not field check Installations or verify thatthe mounting system is Installed as described In this engineering report. A To assist the building Inspector In verifying the authenticity of �v�r this proprietary mounting s:al a pe nen ad es' silver reflective "RoofTracm" label, as shown, Is placed on at least one of the main supps or p an n pwith "Professional Solar Prod. Pat 6,360,491" on the /f Tracunderside of rail. Structural attachment Lag bolt attachment should be Installedusing the proper pilot hole for optimum strength, A 5/16" lag qq 6.36t1Aetbolt requires a 3/16" pilot hole. It Is the responsibility of the Installer to Insure a proper attachment Is made to the structural member of the roof. Failure to securely attach to the roof structure may result In damage to equlpment personal Injury or property damage. ES / This office does not express an opinion as to the load bearing characteristics of the structure the mounting system/modules are being Installed on. ICC accredited laboratory tested structural attachments manufactured by Professional Solar Products (including, but not limited to Fastlackc , TIIeTracG, and Foamlacke) can be Interchanged with this system. Check with local building department or AHJ for site specific requirements. *Modules measuring within stated specifications and tested to 1.11-1703, or equivalent are Included In this engineering **Wind loading values relative to defined load values using wind load exposure (125 mph for 5/12 roof pitch or less; 100 mph for greater than 5/12 roof pitch) and gust factor coefficient "exposure C" as defined In the 2009(IBC) /2010(CBC) ***Module tested: 64.6" x 39.4" x 1.7" (sln) ****Est snow load rating of 25lb/ft2 based on 2.0 safety factor 31324 VIA COLINAS STE 101 " WESTLAKE VILLAGE, CA 91362 Page 1 of 2 RT6 2011 Module Area = 18 ftp each 72" �) Approx 20' max overhang Total module (45 lbs ea.) and rail (12 lbs ea.) weight: 159 lbs Number of attachments: 4 ea Weight / attachment point: 40 lbs Area: 54 ft2 Distributed weight: 2.95 Ib/ ft2 5/16" Stainless Steel Hex bolt 5/16" Stainless Steel .---��� Lock Washer Aluminum ProSolar Inter -Module Clamp Aluminum ProSolar 2 Rail nut 2-1/2" Aluminum ProSolar Roofrrac@ Support Rail 3/8" Stainless Steel Hex Bolt and Flat Washer Aluminum ProSolar patented FastJack® Roof Attachment• 5/16" Stainless Steel Lag Bolt and Flat Washer 40" 2,710 lbs / 50 psf ------------- 'Lab tested structural attachments manufactured by Professional Solar Products (including Fast lack® , TileTrac®, and FoamJack®) can be Interchanged with this system. Professional Solar Products Roof7rae Patent# 6,360,491 Photovoltaic mounting system Page 2 of 2 Top Load Deflection: 0.313" 2,710 lbs / 50 psf Up lift Deflection: 0. RoofTrai& Solar Modules Static load test illustration RT6_2011 YGE240 YL240P-29b YL235P-29b SERIESYL225P-29b YL230P-29b YIN 1 OLAR OFFICIAL SPONSOR i1FA WORLDtl1P BfASiI COMPANY Yingli Green Energy (NYSE:YGE) is one of the world's largest fully vertically integrated PV manufacturers. With over 2 GW of modules installed globally, we are a leading solar energy company built upon proven product reliability and sustainable performance. Founded in 1998, Yingli Green Energy serves customers through our U.S. subsidiary, Yingli Americas, co -headquartered in New York and San Francisco. We are the first renewable energy company and the first Chinese company to sponsor the FIFA World Cup'". PERFORMANCE -Industry leading in-house manufacturing of polysilicon, ingots, wafers, cells and modules ensures tight control of our material and production quality. -High performance, multicrystalline solar cells deliver a module series efficiency of up to 14.7%, reducing installation costs and maximizing the kWh output per unit area. - Power tolerance of +/-3% minimizes PV system mismatch losses. QUALITY & RELIABILITY - Robust, corrosion resistant aluminum frame independently tested to withstand wind and snow loads of up to 50 psf and 113 psf, respectively, ensuring a stable mechanical life. -Manufacturing facility certified to IS09001 Quality Management System standards. - Module packaging optimized to protect product during transportation and minimize on-site waste. WARRANTIES - Extensive 5 -year limited product warranty and a 25 -year limited power warranty. - Limited power warranty* = 90% of the minimum rated power output for 10 years, 80% of the minimum rated power output for 25 years. * In compliance with our warranty terms and conditions. QUALIFICATIONS & CERTIFICATES UL 1703 and ULC 1703, UL Fire Safety Class C, CEC, FSEC, ISO 9001:2008, ISO 14001:2004, BS OSHAS 18001:2007, SA8000 c@ Us LISTEDrta�^-, (PHOTOVOLTAIC MODULE) 44DO YINGLISOLAR.COM Yingli Americas YGE240 SERIES ELECTRICAL PERFORMANCE Module name W i W YGE 240 YGE 235 YGE 230 YGE 225 Module type I% V, 17-V YL240P-29b YL235P-29b) YL230P-291b YL225P-23b Power output % Pm.. W ; 240235 A 230 225 Power output tolerances' APS,.. % V. +/-3 34.2 33.8 '+. _tower efficiency X rim % 14.7 14.4 14.1 13.8 Voltage at Pmax V.W V 29.5 29.5 29.5 29.5 Current at Pmax I I, A 8.14 7.97 7.80 7.63 Open -circuit voltage V« V 37.5 37.0 37.0 36.5 Short-circuit current I 6. A ? 8.65 8.54 8.40 8.28 STC: 1000W/m2 irradiance, 25°C module temperature, AM 1.Sg spectrum according to EN 60904-3 2 Premium power output tolerance options are available upon request Electrical parameters at Power output Nominal •. I Pm.. r, W 174.3 • 170.7 a 167.0 163.4 Voltage at Paw. V, 17-V Temperature coefficient of 1. 26.6 26.6 26.6 z 26.6 Current at P.,.. 6rop ( A 6.56 6.42 6.29 6.15 Open -circuit voltage V. V 34.2 33.8 '+. 33.8 33.3 Short-circuit current I� A 7.01 6.92 6.81 # 6.71 NOCT: open -circuit operating cell temperature at 800W/m2 inadiance, 20°C ambient temperature, 1 m/s wind speed THERMAL CHARACTERISTICS Nominal operating cell temperature NOCr i °C 46+/-2 Temperature coefficient of Pm., Y %/°C .0.45 Temperature coefficient of V.. ° 0- %PC -0.37 Temperature coefficient of 1. 0.06 OPERATING CONDITIONS Max. system voltage 600Voc w Max. series fuse rating 15A Operating temperature range -40 to 194°F (40 to 90°C) Max. static load, front (e.g., snow and wind) Max. static load, beck (e.g., wind) 113 psf (5400 Pa) 50 psf (2400 Pa) Hailstone impact 1 in (25 mm) at 51 mph (23 m/s) CONSTRUCTION MATERIALS Front cover (material/type/thickness) low -iron glass / tempered / 3.2 mm Cell (quantity/material/type/dimensions/ares) 60 / polysilicon / muhicrystalline / 156 mm x 156 mm / 243.3 cm2 Encapsulant (material) Ethylene vinyl acetate (EVA) Frame (material/color) Aluminum alloy / anodized silver or black Junction box (protection degree) I IP65 Cable (type/length/gauge/outside diameter) PV Wire / 47.24 in (1200 mm) / 12 AWG / 0.244 in (6.2 mm) Plug connector i Amphenol / H4 / IP68 (manufacturer/type/protection degree) P • The specifications in this datasheet are not guaranteed and are subject to change without prior notice. Yingli Green Energy Americas, Inc. info@yingliamericas.com Tel: +1 (888) 686-8820 YINGLISOLAR.COM I NYSENGE m Yingli Green Energy Holding Co. Ltd. 1 YGE240Sedes-EN-201107-v01 GENERAL CHARACTERISTICS Dimensions (L/W/H) 64.96 in (1650 mm) / 38.98 in (990 mm) / 1.97 in (50 mm) Weight 43.0 lbs (19.5 kg) PACKAGING SPECIFICATIONS Number of modules per pallet 20 Number of pellets per 53' container - 36 Packaging box dimensions (L/W/H) 67 in (1700 mm) / 45 in (1150 mm) / E 47 in (1190 mm) Box weight 941 lbs (427 kg) Units: inch (mm) 38.98 (990) 37.24 (946) 1.97 (50) W Grounding holes lO.l o 2-00.236 (6) o 'O a a P o Mounting holes 4-0.256x0315 (65x8) Draukage holesti 8-00.157 (4) Q A A P a `` .47(12) r � 1 r t 1 o t a SECTION ASA k I t r t / � r 1.26 (32J QWarning: Read the Installation and User Manual in its entirety before handling, installing, and operating Yingli modules. Our Partners YINi�LAR SPONFop FSH fa- .FFICIAL� Roof Trac TM Patent #6,360,491 The Original "Top -Down" PV Mounting System. Integrated with Tile Trac' attachments The patented Roof Trac'" system installed with the Tile Trac® attachment method provides an ideal solution for mounting on a the roof. Tile Trac® reduces the possibility of broken tiles and leaking roofs, allowing the installer to make structural attachments to the roof rafter. The Roof Trac" installed with the Tile Trac® allows solar support rails \to be adjusted to compensate for uneven roofs. illustrated above is how the Tile Rac® attachment seamlessly integrates with the Roof 7hac" mounting system. The Me Trac® attachment system is the perfect base for surface mounting on composition roofs! 1t has over 10 sq. inches of base to prevent damaging delicate composition shingles. Patented Slide -N -Clamp System f..n wi SOLAR products .—ter Im Root Trac® & Past Jade" protected under Patent #6,360,491 & Other patents pending. Tile haul protected under Patent #5,646,029. 1 �F. 7e...; 7be Roof Trac"' support rail was designed to conceal all attachment hardware. All connections are made inside the support rail hidden from view. All exposed aluminum is fully anodized to module manufacturer specifications. Fully integrated, and patented, clamping system actually changes the structural properties of the aluminum channel making it significantly stronger. This design allows solar modules to be installed at a lower profile to the roof providing a more aesthetically pleasing installation. Module clamps are specifically designed, extruded and engineered for each specific module frame. Our innovative clamping system provides inward tension on the module frame securing the laminate in the frame. Tbird partyT IeTl ° ab Tested rcl C Lp lbs. �•► Patent #5,146,029 1) Uo t Valu ' Pub° Tile Roof Structural Attachment The patented TileTrac® attachment allows for a structural roof rafter connection with optimal attachment stud location adiustability. Design results in the best looking systems in the industry. Tile Trac ° for s -curve concrete tile (6" Tall Threaded Stud) Part # IN 8-T6 Tile Trac ° for, flat concrete the (4" Tall Threaded Stud) Part # TT -18-T4 Benefits of the TileTrac° • Industry's most cost effective the • Aluminum and Stainless Steel components for attachment product corrosion resistance and strength • Minimal install labor and time • 1,740 lbs of 3rd party lab tested pullout strength • Over 12 years of industry • Water -ti ht seal lab tested for 7 days under 34 preferred design inches of water, zero leakage • Requires only one Stainless Steel • 10 sq. inches of base area evenly distributes roof lag bolt (included) load and provides sufficient sealant bonding area The TileTrac® Design Structurally attaches to roof rafter and allows the rail attachment stud to be located at the strongest point of the tile (the crown) where water does not flow. Without TileTrac® iter With TileTrac® Rafter Water flows in the Valley High Point/ Crown of the Tile (optimum) structurally a"acnea to the rafter Fnomoua 007�1 GRID -TIED INVERTERS FOR PHOTOVOLTAIC SYSTEMS Light Weight At 42 lbs, the FRONIUS IG inverters are the lightest grid -connected inverters making them both easy and cost-effective to install. More Energy MIX'"' Concept allows your system to output more energy under part -load conditions. Lower Cost Integrated UL approved DC & AC disconnects which reduce installation time and complexity - often eliminating the need for additional disconnects. LCD Display User-friendly and comes standard with every FRONIUS IG; tracks more than 20 critical system performance parameters. Powerful At 4000, 4500 and 5100 watts, these inverters deliver more power output for higher performance installations. Reliable Fronius has been in business for over 60 years and has more than 200,000 FRONIUS IG inverters installed worldwide. Warranty 10 year Premium Warranty. (Z a POWERING YOUR FUTURE DC Input Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500 -LV Recommended PV power 3000 - 5000 Wp 4000 - 6300 Wp 3600 - 5500 Wp Max. DC input voltage 500 V 500 V 500 V Operating DC voltage range 150 - 450 V 150 - 450 V 150 - 450 V Max. usable DC input current 26.1 A 33.2 A 29.3 A AC Output Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500 -LV Maximum output power 040° C 4000 W 5100 W 4500 W Nominal AC output voltage 240 V 208 V Utility AC voltage range 212 - 264 V (240 V +10% / -12%) 183 - 229 V Maximum AC current 16.7 A 21.3 A 21.6 A Maximum utility back feed current 0.0 A 0.0 A 0.0 A Operating frequency range 59.3 - 60.5 Hz (60 Hz nom) Total harmonic distortion <5% Power Factor (cos phi) 1 General Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500 -LV Max. efficiency 95.2% 95.2% 94.4% Consumption in stand-by < 0.15 W (night) Consumption during operation 15 W Enclosure NEMA 3R Size (Ixwxh) 28.4 x 16.5 x 8.8 in (720 x 418 x 223 mm) Weight 42 Ibs. (19 kg) Ambient temperature range -5 to 122 T (-20. to +50 °C) Cooling controlled forced ventilation Integrated DC and AC disconnects standard UL approved DC & AC disconnects Protections Ground fault protection Internal GFDI, in accordance with UL 1741 DC reverse polarity protection Internal diode Islanding protection Internal, in accordance with UL 1741, IEEE 1547 Over temperature Output power derating Surge Protection Internal DC & AC protection, Tested to 6 kV Compliance Safety UL 1741 EMI FCC Part 15; Class A & B Anti-Islanding protection UL 1741, IEEE 1547 Ground fault detector and interrupter Compliant with NEC Art. 690 requirements, UL 1741 Miscellaneous Maximum AC over current protection Two -pole, 30 A circuit breaker AC wire sizing Use maximum AWG 6 194°F (90 °C) copper wire DC wire sizing Use maximum AWG 6 194°F (90 °C) copper wire AC disconnect 32 A DC disconnect 40 A Warranty 10 year Premium Warranty is Standard Distributed by Fronius USA LLC Solar Electronic Division 10421 Citation Drive Suite 1100 Brighton, Mi 48116 Phone: 810-220-4414 Fax: 810-220-4424 E -Mail: pv-us@fronius.com www.fronius-usa.com r�t 91. Product Data Sheet DU222RB -SWITCH NOT FUSIBLE GD 240V 60A 2P NEMA3R bySehneider Electric List Price $353.00 USD Availability. Stock Item: This item is normally stocked in our distribution facility. Technical Characteristics Number of Poles 2 -Pole Terminal Type Lugs Type of Duty General Duty Maximum Voltage Rating 240VAC Wire Size #10 to #2 AWG(AI) - #14 to #2 AWG(Cu) Action Single Throw Ampere Rating 60A Approvals UL Listed File Number E2875 Enclosure Rating NEMA3R Enclosure Type Rainproof and Sleet/Ice proof (Indoor/Outdoor) Factory Installed Neutral No Disconnect Type Non -Fusible Mounting Type Surface Shipping and Ordering Category 00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R Discount Schedule DE1A GTIN 00785901491491 Package Quantity 1 Weight 4.7 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Returnability Country of Origin MX As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. Generated: 09/14/2011 14:56:20 ® 2011 Schneider Electric. All rights reserved. Schneider • i?Electric