MBA 2018-0001 to SA 2018-0004 Target (03.13.2018) 78-495 Calle Tampico La Quinta, CA 92253 760.777.7000
March 13, 2018
Mr. Brian Leung
Kimley Horn
765 The City Drive, Suite 200
Orange, CA 92868
SUBJECT: MODIFICATION BY APPLICANT 2018-0001
TARGET EXTERIOR REFRESH APPROVAL
Dear Mr. Leung:
The Design and Development Department has reviewed your request for a modification to the
existing Target commercial building, located at 78935 Highway 111. The modifications
include repainting and refreshing exterior walls, monument sign, and building mounted signs.
It has been determined that said plan modifications are minor, will not result in a significant
change in the project as approved by the decision-making authority, and comply with the
spirit and intent of the Washington Park Specific Plan. Therefore, the design modification is
approved as shown on the attached exhibits, subject to the following conditions of approval:
1.The applicant shall secure building and demolition permit approval from the Building
division prior to the initiation of any work.
2.The applicant shall comply with Sign Application 2018-0004 for the new signs.
Should you have questions, please contact me at 760-777-7069.
Sincerely,
Carlos Flores
Associate Planner
T-1867 La Quinta, CA: Exterior Elevation Refresh February 20, 2018
Proposed Elevations
Front Elevation
Right Elevation
Rear Elevation
Left Elevation
EIFS
C-1 “TARGET RED”
(E) STONE VENEER
(E) STONE VENEER
(N) 14’-0” BULLSEYE
(E) STONE VENEER
(E) STONE VENEER
(E) STONE VENEER
(E) BULLSEYE TO REMAIN, REFURBISH AS NEEDED
DEMO (E) FIN
(N) EIFS
55’-0”3’-0”
10’-0”36’-0”3’-0”7’-0”17’-2”48’-8”
(N) CANTILEVERED EIFS FIN
(E) COLUMNS
(E) SIGN TO REMAIN
(E) GRAPHIC LOGO TO REMAIN,
REFURBISH AS NEEDED
(E)BRONZE ENTRY/STOREFRONT
(E) BRONZE ENTRY/STOREFRONT
(N) EIFS
(N) EIFS
REPAINT TO MATCH EXISTING FINISHES
REPAINT TO MATCH EXISTING FINISHES
REPAINT TO MATCH EXISTING FINISHES
REPAINT TO MATCH EXISTING FINISHES24’-0”(E) C-41 “MEDIUM TERRA COTTA” - TK
PRODUCTS CUSTOM FORMULATION
(E) C-42 “MEDIUM KHAKI” - TK
PRODUCTS CUSTOM FORMULATION
(E) C-43 “LIGHT KHAKI” - TK
PRODUCTS CUSTOM FORMULATION
(E) C-44 “LIGHT TERRA COTTA” - TK
PRODUCTS CUSTOM FORMULATION
(E) C-45 “DARK KHAKI” - TK
PRODUCTS CUSTOM FORMULATION
EXISTING
NEW
(E)
(N)
(E) STONE VENEER
(N) ORDER PICKUP SIGN
PLANNING APPROVAL
ADMINISTRATIVE
CASE# ____________________
EXHIBIT# ____________________
INITIAL cflores
DATE 03/13/2018 10:12:00 AM
MBA2018-0001
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
122
EXISTING CONDITION OF FRONT ELEVATION
NTS
EXISTING FRONT ELEVATION
Scale: 1/32"=1'-0"
C
A
502'-8"±35'-11"±
T-1867 La Quinta, CA: Exterior Elevation Refresh February 20, 2018
Proposed Front Elevation
Front Elevation
Right Elevation
Rear Elevation
Left Elevation
EIFS
C-1 “TARGET RED”
(E) STONE VENEER
(E) STONE VENEER
(N) 14’-0” BULLSEYE
(E) STONE VENEER
(E) STONE VENEER
(E) STONE VENEER
(E) BULLSEYE TO REMAIN, REFURBISH AS NEEDED
DEMO (E) FIN
(N) EIFS
55’-0”3’-0”
10’-0”36’-0”3’-0”7’-0”17’-2”48’-8”
(N) CANTILEVERED EIFS FIN
(E) COLUMNS
(E) SIGN TO REMAIN
(E) GRAPHIC LOGO TO REMAIN,
REFURBISH AS NEEDED
(E)BRONZE ENTRY/STOREFRONT
(E) BRONZE ENTRY/STOREFRONT
(N) EIFS
(N) EIFS
REPAINT TO MATCH EXISTING FINISHES
REPAINT TO MATCH EXISTING FINISHES
REPAINT TO MATCH EXISTING FINISHES
REPAINT TO MATCH EXISTING FINISHES24’-0”(E) C-41 “MEDIUM TERRA COTTA” - TK
PRODUCTS CUSTOM FORMULATION
(E) C-42 “MEDIUM KHAKI” - TK
PRODUCTS CUSTOM FORMULATION
(E) C-43 “LIGHT KHAKI” - TK
PRODUCTS CUSTOM FORMULATION
(E) C-44 “LIGHT TERRA COTTA” - TK
PRODUCTS CUSTOM FORMULATION
(E) C-45 “DARK KHAKI” - TK
PRODUCTS CUSTOM FORMULATION
EXISTING
NEW
(E)
(N)
(E) STONE VENEER
(N) ORDER PICKUP SIGN
Proposed MaterialsT-1867 La Quinta, CA:
Exterior Elevation Refresh January 12, 2018
C-41
(E) MEDIUM TERRA COTTA
C-42
(E) MEDIUM KHAKI
C-1
TARGET RED
C-43
(E) LIGHT KHAKI
C-44
(E) LIGHT TERRA COTTA
C-45
(E) DARK KHAKI
1.Front elevation facing Hwy 111: location of proposed “order pickup sign” on stone veneer
2.Front elevation facing Hwy 111: proposed cantilevered EIFS finish, removal of “TARGET” signage, proposed white bullseye
3.Existing Target Monument Sign at intersection of Avenue 47 and La Quinta Center Drive. Proposing white bullseye logo
and white lower case “target” channelized lettering with earth tone background
4.Existing Target Monument Sign intersection of Highway 111 and La Quinta Center Drive, refurbish red bullseye logo with
new red bullseye logo and lower case “target” channelized lettering with earth tone background
1 2
3 4
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
121
PHOTOGRAPHIC SITE PLAN
SCALE: N.T.S.
PROPOSED NEW SIGN SCHEDULE
NEW BULLSEYE LOGO WHITE / 14' 153.9 SQ. FT.
QUANTITY: ONE (1)Front Elevation
NEW TOTAL BLDG. SIGNAGE: 273.38 SQ. FT.
A
EXISTING 2'-6" RED CVS PHARMACY LETTERS /57.08 SQ. FT.
QUANTITY: ONE (1)Front Elevation
N
NEW 1'-2" RED ORDER PICKUP CHANNEL LETTERS /24.59 SQ. FT.
QUANTITY: ONE (1)Front ElevationB
Front Elevation
EXISTING SIGN SCHEDULE
EXIST’G RED 12'-0" BULLSEYE LOGO / 2'-3" TARGET LETTERS
QUANTITY: ONE (1)ON FRONT ELEVATION TO BE REMOVED & REPLACEDA140.1 SQ.FT
EXISTING TOTAL BLDG. SIGNAGE: 197.18 SQ. FT.
C EXIST’G RED 2'-6" CVS PHARMACY LETTERS
QUANTITY: ONE (1)ON FRONT ELEVATION TO REMAIN AS IS. NO CHANGE
57.08 SQ.FT
C
D
PROPOSED GROUND SIGN SCHEDULE
5
0
5
'
-
1
0
"±288'-8"±
NEW 3'-6" RED FCO BULLSEYE LOGO /9.61 SQ. FT.
QUANTITY: ONE (1)
Rear ElevationENEW 6'-0" RED BULLSEYE LOGO /28.2 SQ. FT.
QUANTITY: ONE (1)
F
G
NEW BULLSEYE LOGO WHITE & 10 3/4" target LETTERS / 3'-6" 33.24 SQ. FT.
QUANTITY: TWO (2)On La Quinta Center Drive Monument Sign
NEW BULLSEYE LOGO WHITE & 10 3/4" target LETTERS / 3'-6" 33.24 SQ. FT.
QUANTITY: TWO (2)On Avenue 47 Monument Sign
NEW TOTAL MONUMENT SIGNAGE: 66.48 SQ. FT.
G
F
B
A
D C
E
A
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
123
SCOPE OF WORK:
EXISTING BULLSEYE & TARGET | ONE (1) SET
EXISTING SIGN TO BE REMOVED & DISPOSED.
A 140.1 SQ.FT
A
B
C D E
SIGN TYPE A B C D E SQ.FT.QTY
1
ACRYLIC FACED INTERNALLY ILLUMINATED CHANNEL LET TERS
EXISTING TO REMAIN AS IS. NO ACTION.CHANNEL LOGO & LETTERS
C
SCOPE OF WORK:
CVS-30-CL 57.0829 1/8"22'-10 "3'-1"6'-8"12'-2 1/4"
A
F
B
G H I J K
D
C
E
SIGN TYPE A B C D E HF IG J K SQ.FT.AMPS
CIRCUITS
RETAINER
LL144/27S-R 12'-0"12'-0"12'-0"2'-0"2'-0"12"4'-0"2'-3"2'-0"2'-0"15'-8"113.1/27.0
logo/letters logo/letters
1.5" RET. / 1" T.C.
113.1/27.0
FIELD SURVEY REQUIRED
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
124
PROPOSED STORE FRONT ELEVATION1Scale: 1/32"=1'-0"
PROPOSED RIGHT SIDE ELEVATION2Scale: 1/32"=1'-0"
505'-10"±35'-0"±24'-0"10'-0"14'-0"58'-0"20'-4"12'-10"
1'-2"
13'-5"
22'-10"
2'-6"
3'-6"25'-0"20'-3"288'-3"±35'-0"±CAB
23'-7 1/2"
D
2'-2 1/2"
14'-0"
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
125
PROPOSED LEFT SIDE ELEVATION 3 Scale: 1/32"=1'-0"
PROPOSED REAR ELEVATION4Scale: 1/32"=1'-0"
505'-10"±27'-10"±288'-8"35'-8"±8'-0"±
6'-0"23'-8"±E
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
126
A
B
C D E F G
ACRYLIC FACED INTERNALLY ILLUMINATED "BULLSEYE"
MANUFACTURE AND INSTALL CHANNEL LOGO AS SHOWN AND NOTED
SIGN TYPE A
A
B C D E F G SQ.FT.QTYRETAINER
ANY DEVIATION FROM FEDERAL HEATH
REQUIREMENTS MAY RESULT IN DAMAGE
TO OR IMPROPER OPERATION OF SIGNAGE,
CAUSING DELAYS AND ADDITIONAL COSTS.
ELECTRICAL REQUIREMENTS
Total: 0.0 Amps
( 1 ) 120V 20A Circuit Required.
ALL BRANCH CIRCUITS SHALL BE
DEDICATED TO SIGNS (INCLUDING
GROUND AND NEUTRAL) AND SHALL
NOT BE SHARED WITH OTHER LOADS.
6"
.063 ALUMINUM RETAINER
.080 ALUMINUM FILLER
INTERIOR PAINTED: WHITE
MINIMUM .090 ALUMINUM BACK
ALL MOUNTING HARDWARE (INCLUDING SPACERS)
TO BE SUPPLIED BY: INSTALLER
MINIMUM 3/8” STAINLESS STEEL MOUNTING HARDWARE
SLOAN LED
(2) - WEEP HOLES PER LOW SPOT
½" ELECTRICAL BEYOND SIGN
BY INSTALLER.
INSTALLER TO PROPERLY SEAL WALL.
PIGMENTED ACRYLIC FACES
WALL
J-BOX BY INSTALLER
LOCK-ABLE DISCONNECT
SWITCH BY OWNER-WIRED
BY ELECTRICIAN.
(1 PER CIRCUIT)
EXISTING
ELECTRICAL
PANEL
12 V CLASS TWO POWER
SUPPLY, SUPPLIED BY;
FEDERAL HEATH
MOUNTED BY: SUB-CONTRACTOR
SPACE MAXIMUM 1"
MINIMUM ½"
POWER DISTRIBUTION BOARD
BY: FEDERAL HEATH
CLASS 2 SECONDARIES TO DISTRIBUTION BOARD
TO BE RUN THROUGH CONDUIT SUPPLIED BY
INSTALLER AND WIRED BY INSTALLER.
DISTRIBUTION BOARD AND POWER SUPPLIES
SUPPLIED BY FEDERAL HEATH SIGN CO.
SEALER: BASF-MasterSeal NP 150
END VIEW
6"SPACE MAXIMUM 1"
MINIMUM ½"
Trimcap/Retainer Trimcap/Retainer
WHITE
7328 WHITE
ATUGLAS
Acrylic
WHITE Sloan White
LED
MATERIAL FINISH COLORS
Returns Faces Retainer/Trim-Cap Illumination
LOGO/WALL DETAIL NOT TO SCALE
(Generic)
1168 BULLSEYE-W 14'-0"14'-0"2'-4"2'-4"2'-4"2'-4"4'-8"1 ½"153.9
NOTE: ENGINEERING REQUIRED FOR RED WALL PANEL
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
127
ANY DEVIATION FROM FEDERAL HEATH
REQUIREMENTS MAY RESULT IN DAMAGE
TO OR IMPROPER OPERATION OF SIGNAGE,
CAUSING DELAYS AND ADDITIONAL COSTS.
ELECTRICAL REQUIREMENTS
Total: 0.0 Amps
( 1 ) 120V 20A Circuit Required.
ALL BRANCH CIRCUITS SHALL BE
DEDICATED TO SIGNS (INCLUDING
GROUND AND NEUTRAL) AND SHALL
NOT BE SHARED WITH OTHER LOADS.
LOGO/LETTER WALL DETAIL NOT TO SCALE
5"
1" TRIM CAP
.040 ALUMINUM FILLER
PRE-FINISHED ALUMINUM
MINIMUM .063 ALUMINUM BACK
ALL MOUNTING HARDWARE (INCLUDING SPACERS)
TO BE SUPPLIED BY: INSTALLER
MINIMUM 3/8” STAINLESS STEEL MOUNTING HARDWARE
SLOAN LED
WEEP HOLES PER LOW SPOT
½" ELECTRICAL BEYOND SIGN
BY INSTALLER.
INSTALLER TO PROPERLY SEAL WALL.
PIGMENTED ACRYLIC FACES
WALL
J-BOX BY INSTALLER
LOCK-ABLE DISCONNECT
SWITCH BY OWNER-WIRED
BY ELECTRICIAN.
(1 PER CIRCUIT)
EXISTING
ELECTRICAL
PANEL
12 V CLASS TWO POWER
SUPPLY, SUPPLIED BY;
FEDERAL HEATH
MOUNTED BY: SUB-CONTRACTOR
POWER DISTRIBUTION BOARD
BY: FEDERAL HEATH
CLASS 2 SECONDARIES TO DISTRIBUTION BOARD
TO BE RUN THROUGH CONDUIT SUPPLIED BY
INSTALLER AND WIRED BY INSTALLER.
DISTRIBUTION BOARD AND POWER SUPPLIES
SUPPLIED BY FEDERAL HEATH SIGN CO.
SEALER: BASF-MasterSeal NP 150
(Generic)
ACRYLIC FACED INTERNALLY ILLUMINATED CHANNEL LETTERS
MANUFACTURE AND INSTALL CHANNEL LETTERS AS SHOWN AND NOTED
END VIEW
5"
SPACE MAXIMUM 1"
MINIMUM ½"
AC
B
SIGN TYPE A B C SQ.FT.QTY
1
Red Sloan Red
LED
MATERIAL FINISH COLORS
Returns Trimcap/Retainer Illumination
MP# 82074LVG
(FULL GLOSS)
2793 LD Red
Modified Acrylic
(Altuglas or Equiv.)
Faces
1'-2"OPU14-REMOTE-R 1'-11"24.5912'-10"
B
NOTE: ENGINEERING REQUIRED FOR STONEWOOD VENEER
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
128
END VIEW
A
B
C D E F G
FLAT CUT OUT ALUMINUM "BULLSEYE" LOGO
MANUFACTURE AND INSTALL FCO LOGO AS SHOWN AND NOTED
SIGN TYPE A B C D E F G SQ.FT.QTY
42 BULLSEYE-R 1
MATERIAL FINISH COLORS
ALUMINUM
MP# 82074LVG
(FULL GLOSS)
Mounting Surface
1/4" Aluminum Spacer,
Typical
1/8" Thick FCO
Aluminum
3/16" Diameter Aluminum
Studs, Min. 3 Per Element
painted t/m MP#82074LVG
Full Gloss
3'-6"3'-6"7"7"1'-2"7"7"9.61
D
FCO LOGO
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
129
END VIEW
6"SPACE MAXIMUM 1"
MINIMUM ½"
A
B
C D E F G
ACRYLIC FACED INTERNALLY ILLUMINATED "BULLSEYE"
MANUFACTURE AND INSTALL CHANNEL LOGO AS SHOWN AND NOTED
SIGN TYPE A B C D E F G SQ.FT.QTYRETAINER
ANY DEVIATION FROM FEDERAL HEATH
REQUIREMENTS MAY RESULT IN DAMAGE
TO OR IMPROPER OPERATION OF SIGNAGE,
CAUSING DELAYS AND ADDITIONAL COSTS.
ELECTRICAL REQUIREMENTS
Total: 0.0 Amps
( 1 ) 120V 20A Circuit Required.
ALL BRANCH CIRCUITS SHALL BE
DEDICATED TO SIGNS (INCLUDING
GROUND AND NEUTRAL) AND SHALL
NOT BE SHARED WITH OTHER LOADS.
LOGO/WALL DETAIL NOT TO SCALE
6"
.063 ALUMINUM RETAINER
.080 ALUMINUM FILLER
INTERIOR PAINTED: WHITE
MINIMUM .090 ALUMINUM BACK
ALL MOUNTING HARDWARE (INCLUDING SPACERS)
TO BE SUPPLIED BY: INSTALLER
MINIMUM 3/8” STAINLESS STEEL MOUNTING HARDWARE
SLOAN LED
(2) - WEEP HOLES PER LOW SPOT
½" ELECTRICAL BEYOND SIGN
BY INSTALLER.
INSTALLER TO PROPERLY SEAL WALL.
PIGMENTED ACRYLIC FACES
WALL
J-BOX BY INSTALLER
LOCK-ABLE DISCONNECT
SWITCH BY OWNER-WIRED
BY ELECTRICIAN.
(1 PER CIRCUIT)
EXISTING
ELECTRICAL
PANEL
12 V CLASS TWO POWER
SUPPLY, SUPPLIED BY;
FEDERAL HEATH
MOUNTED BY: SUB-CONTRACTOR
SPACE MAXIMUM 1"
MINIMUM ½"
POWER DISTRIBUTION BOARD
BY: FEDERAL HEATH
CLASS 2 SECONDARIES TO DISTRIBUTION BOARD
TO BE RUN THROUGH CONDUIT SUPPLIED BY
INSTALLER AND WIRED BY INSTALLER.
DISTRIBUTION BOARD AND POWER SUPPLIES
SUPPLIED BY FEDERAL HEATH SIGN CO.
SEALER: BASF-MasterSeal NP 150
(Generic)
1
Red Sloan Red
LED
MATERIAL FINISH COLORS
Returns Trimcap/Retainer Illumination
MP# 82074LVG
(FULL GLOSS)
2793 LD Red
Modified Acrylic
(Altuglas or Equiv.)
Faces
72 BULLSEYE-R 6'-0"6'-0"1'-0"1'-0"1'-0"1'-0"2'-0"28.21"
E
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
1210701507-WP701507-WP701507-WP701507-WPSHIPPING NOTE:
PLEASE SHIP ALUMINUM PANELS WITH POWER SUPPLIES
IN THE SAME CONTAINER.
701507-WP
END VIEW
.125 ALUMINUM PAN POWER DISTRIBUTION BOARD
(PDB) WITH 3/8” DIA. HOLES FOR MOUNTING
BY FEDERAL HEATH SIGN.
120 V ON/OFF DISCONNECT, CONDUIT
AND PRIMARY TO PDB INSTALLED
AND PROVIDED BY G.C. ELECTRICIAN.
TYPICAL ELECTRICAL COMPONENTS SHOWN,
SUPPLIED BY INSTALLER - TO BE UL LISTED AND
APPROVED PER NEC 2005 NEC 600-4, 600-3,
FBS 4505-4 & DESIGNED TO U.L. 48 PER F.S. 553-19.
SLOAN POWER SUPPLIES BY FEDERAL HEATH SIGN.
INSTALLED TO BOARD BY SIGN INSTALLER.
ELECTRICAL ( 2’-0” ) WHIP TWHN #12 WITH TYPICAL
ELECTRICAL COMPONENTS SHOWN, SUPPLIED BY
INSTALLER - TO BE UL LISTED AND APPROVED
PER NEC 2005 NEC 600-4, 600-3, FBS 4505-4 &
DESIGNED TO U.L. 48 PER F.S. 553-19.
BUSHING PROVIDED BY SIGN INSTALLER.
CLASS 2 12VDC 120/240 SECONDARY WIRES
2'-0"2'-2"2'-0"
2'-2"
1/2"
scale 1 1/2" = 1'-0"
ISOMETERIC VIEW (Power Distribution Board)(Generic)
PLAN VIEW (Power Distribution Board) (Typical)
scale 1 1/2"=1'-0"
SCOPE OF WORK:
FEDERAL HEATH SIGN TO MANUFACTURE A “POWER DISTRIBUTION BOARD” - ( PDB).
TO BE .125 ALUMINUM BREAK FORMED PANEL ½” DEEP.
PDB TO HAVE 3/8” MOUNTING HOLES PRE- DRILLED.
INSTALLER TO MOUNT LETTERS TO EXTERIOR WALL AND RUN SECONDARY LEADS IN CONDUIT THROUGH WALL INTO A HANDI-BOX.
CONDUIT THROUGH WALL TO BE SEALED FROM WEATHER WITH APPROPRIATE SEALANT SUPPLIED BY INSTALLER.
INSTALLER TO WIRE ALL SECONDARY JUMPS TO CORRESPONDING LETTERS INSIDE BUILDING.
INSTALLER TO WIRE SECONDARY LEADS TO POWER DISTRIBUTION BOARD THROUGH CONDUIT.
INSTALLER TO COORDINATE LOCATION OF POWER DISTRIBUTION BOARD WITH TARGET ON SITE REPRESENTATIVE PER (E-8 SITE ELECTRICAL DRAWINGS).
INSTALLER TO MOUNT PDB WHERE REQUIRED.
PDB MAXIMUM DISTANCE FROM SIGNAGE IN ANY ONE DIRECTION IS 150 FEET.
PDB TO BE MOUNTED USING ADEQUATE HARDWARE SUPPLIED BY INSTALLER.
ELECTRICIAN IS TO SUPPLY AND RUN PRIMARY, CONDUIT AND DISCONNECT SWITCH TO PDB AND MAKE FINAL CONNECTION.
ALL WORK TO BE DONE PER NEC, UL-48 AND LOCAL CODES.
ELECTRICAL WIREWAY
.125 ALUMINUM PAN POWER DISTRIBUTION
BOARD BY FEDERAL HEATH SIGN
SLOAN POWER SUPPLIES BY FEDERAL HEATH SIGN
INSTALLED TO BOARD BY SIGN INSTALLER
NOTE:
POWER SUPPLY QUANTITY DEPENDENT ON SIGNAGE REQUIRED.
INSTALLATION REQUIREMENT:
power distribution board (pdb) to be mounted no more then 12” above
ceiling to the bottom of the pdb. refer to design drawings for specific
location of pdb. pdb to be mounted so that it is easily accessible from
a step ladder.
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
1211
EXISTING LOOK MONUMENT ON LA QUINTA CENTER DRIVE NTS
NEW LOOK MONUMENT ON LA QUINTA CENTER DRIVE NTS
EXISTING LOOK MONUMENT ON AVENUE 47 NTS
NEW LOOK MONUMENT ON AVENUE 47 NTS3'-6"8 1/2"3'-6"8 1/2"3'-6"10 3/4"3'-6"10 3/4"F G
Boyd Hippenstiel
Sandra Ramirez
Virgo S. Aragones/CHC Store: #T1867
78935 US HWY 111
LA QUINTA , CA 92253
23-44769-10
22 February 2018
23-44769-10
1212
ANY DEVIATION FROM FEDERAL HEATH
REQUIREMENTS MAY RESULT IN DAMAGE
TO OR IMPROPER OPERATION OF SIGNAGE,
CAUSING DELAYS AND ADDITIONAL COSTS.
ELECTRICAL REQUIREMENTS
Total: 0.0 Amps
( 1 ) 120V 20A Circuit Required.
ALL BRANCH CIRCUITS SHALL BE
DEDICATED TO SIGNS (INCLUDING
GROUND AND NEUTRAL) AND SHALL
NOT BE SHARED WITH OTHER LOADS.
SIDE VIEW
SCOPE OF WORK:
MANUFACTURE AND INSTALL CHANNEL LOGO & LETTERS
ACRYLIC FACED INT. ILLUM. "LOGO & LETTER SET" | LC -S W
White Sloan White
LED
MATERIAL FINISH COLORS
Returns Trimcap/Retainer Illumination
WHITE 7328 White
ATUGLAS
Acrylic
Faces
A
A
D D E D D
C
B
SIGN TYPE A B C D E SQ.FT.RETAINER AMPS
CIRCUITS
LL42/10 3/4 LC-S W 3'-6"4'-9"1'-2"10 3/4"7"1"16.625
F G&
REMOVE EXISTING CHANNEL LOGO & LETTERS AND DISPOSE.
FOUR (4) SETS REQ'D for TWO (2) MONUMENT SIGN
PATCH AND PAINT C-45 SW 7033 BRAINSTORM BRONZE.
CUSTOM SIZE
T-1867 La Quinta, CA: Exterior Elevation Refresh February 20, 2018
Site PlanLA QUINTA CENTER DRIVEU
S
HW
Y
1
1
1
AVENUE 47WASHINGTON ST(E) MONUMENT SIGN:
REFURBISH RED BULLSEYE LOGO WITH NEW
WHITE BULLSEYE LOGO AND LOWER CASE
“target” CHANNELIZED LETTERING
(E) MONUMENT SIGN:
REFURBISH RED BULLSEYE LOGO WITH NEW
WHITE BULLSEYE LOGO AND LOWER CASE
“target” CHANNELIZED LETTERING
NOTE (E) PYLON SIGN BACKGROUND:
SITE SIGNS ARE RED WITH A LIGHT
EARTH TONE BACKGROUND, UPDATE
SIGNS TO BE WHITE WITH A DARK
EARTH TONE BACKGROUND.
(E) PYLON SIGN, TYP
(E) BACKGROUNDCOLORS TO REMAIN
SIGN ELEVATION - NTS SIDEFRONT
REPAINTC-45 REPAINTC-45
C-45 SW 7033 BRAINSTORM BRONZE