Loading...
14-514 (AR)78-495 CALLE TAMPICO LAQUINTA, CALIFORNIA 92253 Application Number: AR -14-514 Property Address: 81307 JASMINE CT APN: 764280999 Application Description: Property Zoning: Application Valuation: $50,000.00 T4t!t D VOICE (760) 777-7125 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 8/7/2014 Owner: PAUL KLEIN 81-307 JASMINE CT LA QUINTA, CA 92253 Applicant: W V Contractor: ALL VALLEY CONSTRUCTIOND UG 2014 ALL VALLEY CONSTRUCTION 39-813 CLEMENTY WAY ' Q ®� 39-813 CLEMENTY WAY MURRIETA, CA 92563 p MURRIETA, CA 92563 MM 0 oEQE � M pEPMTM'Etn ll UMr (760)774-5786 l LIc. No.: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: _ License No.: _ Date: Contractor* OWNEIRBDEIR DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business 44 and Professions Code) or that he or she is exempt therefrom and the basis for the alleges exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the / applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:_ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3 0 of he Labor Code, I shall forthwith comply with those provisions. 'bate: Z�MApplicant: WARNING: FAILURE TO SECURE W R S' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state la///w���s relating to building construction, and hereby authorize representatives of this city t>3 9nter upon th mentioned property property for inspection purposes. / / -7::;: Date: Signature (Applicant or Agent DESCRIPTION FINANCIAL •• ACCOUNT 1. CITY AMOUNT PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $61.49 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.16 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.12 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF PC 101-0000-42600 0 $168.74 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forADDITION: $367.51 $0.00 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $0.00 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 0.75 $52.50 $0.00 ' PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forCITY STAFF - PER HOUR: $52.50 $0.00 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $143.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.19 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL - NEW CONSTRUCTION: $190.19 $0.00 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE HOURLY PLAN CHECK 10160003428200 $157.50 PAID BY METHOD RECEIPT # CHECK # CLTD BY •. Total Paid forHOURLY PLAN CHECK $157.50 DESCRIPTION. ACCOUNT. CITY AMOUNT PAID PAID'DATE APPLIANCE REPAIR/ALTERATION • 101-0000-42402 0 $11.92 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION `ACCOUNT CITY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.77 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for MECHANICAL: $16.69 $0.00 DESCRIPTION, ACCOUNT CITY AMOUNT PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $6.50 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $6.50 $0.00 TOTALS:• •0 I Bit, # City of La Quinta Building 8T Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permi # \� Project Address: L 0 7 S Wz Gjr Owner's Name: PA U A. P. Number: . 6 _2 .. 9 Address: P13U � S k/4 C- Legal Description: City, ST, Zip: Contractor: L Lt' t�CJlti V� S� u U� 2 G 1 telephone: Address:. J 9,k 13 vj,6 V Project Description: City, ST, Zip: M U Q,& i C—f C d , q2,5,6-? X L-) 1.T/ 7a Telephone: 7 O— Z S 2 State Lic. # : 06- 6,T0 City Lic. C Arch., Engr., Designer: I r • 8 2014 Address: gjfiCI?yOFM City., ST, Zip: ®&@COpME i Telephone: \ Construction Type: Occupancy: a i# State Lic. Project tYPa (circle e ne • New Add'n Alter Repairair Demo 0 Name of Contact Person: J-1 KIA Sq. Ft.: 268 # Stories: —71# Units: Telephone #,of Contact Person: % 6•©- 7 — S 7Ff 6 Estimated Value of Project: £j o 6 60 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, read or correction Plan Check Deposit Truss Calcs. -Called Contact Person Plan Check Balance. Title 24 Calcs. —Zi Plans picked u �14v Construction Flood plain plan Plans resubmitted Mechani Grading plan 2nd Review, ready)/ ssue Electric • Subcontactor List Called Contact PersonPlu bingt S.M. . Grant DeedPlans picked up H.O.A. Approval Plans resubmitted Gradi Ll IN IiOUSE:- '"' Review, ready for correctio s/issue $ 5 D el per Impacf Fee Planning Approval Called Cbntact Person A. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees F;'` aachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: =1 10 Date: August 7, 2014 Owner's Name: Paul Klein Phone No. Project Address: 81-307 Jasmine Ct., LaQuinta Project Description: Addition to existing casita APN: 764-280-999 Type of Development: Tract #: Lot #'s: Residential XX Total Square Feet of Building Area: Commercial 268 Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is autliorizeAto sign on behalf of the owner/developer. Dated: August 7, 2014 • Signature: **********************************************IV********************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code 17620 65995 Number of Sq.Ft. 268 Amount per Sq.Ft. $0.00 Amount Collected $0.00 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Secretary Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs/devfees/cei-tificate of compliance form updated 3-2007 . 11/2010 Trilogy at La Quinta 60-750 Trilogy Pkwy La Quinta, CA 92253 Ph: 760-777-6059 Fax: 760-777-1620 Friday, May 23, 2014 Annie C. Klein 81307 Jasmine Ct La Quinta CA 92253 RE: Design Review Modification Conditionally Approved 81307 Jasmine Ct / Customer ID #: TRLAQ-1193-01 Dear Annie C. Klein: Trilogy Trilogy at La Quinta Maintenance Association We are pleased to inform you that your plans for extending the casita, installing a new spa and barbecue and restoring any landscape damages caused due to construction received on May 12, 2014, have been approved by the Design Review Committee with the following conditions: 7, 8, 9, 12, 13, 14 and 19 (see attached copy). Please note: Any damages caused by contractors due to construction must be repaired; all irrigation and landscape shall be restored to original condition. This approval does not constitute consent by the Association for the applicant to encroach, trespass, or build on any property other than that of the applicant. This approval is related solely to the items reserved for approval by the CC&R's in accordance with the Design Review Guidelines. The approval does not extend to the quality of work done by your architect, or contractor, or to any structural engineering, soils engineering, or site grading and drainage design. You are urged to obtain the services of a state licensed professional for consultation as needed. The Design Review Committee is composed of volunteers. As such, it does not review applications to ensure compliance with building codes, or other local or state laws. Please be advised that this approval does not,relieve you from obtaining any necessary building permits from the governmental agencies involved to ensure compliance with these codes. Any violations of these ordinances will be your responsibility to correct. Thank you for your patience in this matter and for complying with the Association's policies and standards. Sincerely, For the Design Review. Committee, Mirna Hernandez Asst Manager On -Site Property Enclosures cc: Board of Directors Design Review Committee JUN 052;1.1 CITY OF LA QVINYA COMMUNITY DEVELOPM NY TRILOGY AT LA QUINTA H.O.: CONDITIONS OF APPROVAL Property Address: p l D' 1 �QS11� 161- Date Reviewed: I I Conditions Your plans liave been approved, proxided that you meet die, items checked below and all work is consistent widi the of Approval Design Guidelines. . : The patio cover material must be Alumna wood or other similar wood like construction. Roofing materials sliall 1 match die roof material of the dwelling or be open wood lattice 2 The color of diepatio cover matches die home's stucco, accent, fascia or white. Any patio cover or awning to be installed and attached to die home must be installed iu such a manner that it 3 does not compromise die integrity of die water permeability of die home. Due to die patio cover's size it must be constructed with variable heights or must be constructed in two sections 4 with a separation iih between 5 Tlhe size of die patio cover is limited to die size of die proposed patio slab. .The proposed retractable awning may not be a striped awning. It must be a nneutrtl color that blends with the 6 home. Please submit a sample of the fabric. 7 Obtain services of a state licensed professional for consultation. (:)btaihh necessary building permits from die city of La Quiileta, meeting setback rcluirenneats per city code and J $ nnainntain die existing drainage. g Maintain positive drainage iu accordance with die Trilogy Design Guidelines (Section 3.8). 10 The screen door must be the color of the house stucco or be black. 11 it uac ergroun drainage nage is unsta ec , drain rain nee s to terminate in he grass swa e ani e h us with he Lur an capped with a ho -up drain cover. Pooli spa, founntainn, and air conditioning equipment set backs must comply with City of I.a Quiuta codes. All equipment shall be located, screened, or recessed in a manner so as to not be viewable from any lot or street and 12 die noise from die equipment attenuated for die adjacent property owners. Pool set backs are (i" for lharclscape all(] 18" for water lice. 13 The color of -die propose(U-�� natural or a neutral toile. — - Rear yard may not exceed 70% lnardscape and must have a nhinimum of 30916 softscape, measured From die rear 714 building face of- wall to die side property lilies. Proposed planting meets with the Trilogy Rear Yard Minimunn. Planting Requirements standards aid all plants 15 are included oil dee Revised Approved Planet List contained in die Design Guidelines. The proposed wall or iron work to match the existing developer retaining wall in material, style and color or shall 16 be die Frazee Paint color specified in dee guidelines. Replace block wall per Shea Homes standard block wall specification, if removing any portion of block wall to 17 gain access to rear or side yard (requires inspection of rebar:before cap is installed). 18 Refer to. Exhibit "Fis dee Design Guidelines. (Block Wall Design). X 19 When work is completed, please submit Notice of Completion form attached. 20 Make sure rear yard property line pias (markers) remain during cohnstruetioa (applies to golf course lots only) 21 All contractors must meet the Association representative prior to commencing construction. 22 Resubmit showing drainage flow/plains. 23 See notes on plans (if any) 24 1Ali independent irrigation controller must be used for die rear yard, it canunot be tied into the Front yard. Notes MULCSOCIATIONS%Tdloov at La 04ntalARCMTECTURALADRC Fom %Conditkm of An vg BUILDING ENERGY ANALYSIS REPORT PROJECT: Mr. & Mrs. KLEIN's - Casita Addition 81307 JASMINE CT La Quinta, Ca 92253 Project Designer: I Report Prepared by: Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 APR 2`8 LA 9U7•, Job Number: "Ily OF LA QUiNTq LQ042114 BUILDING & SAEETY LVED Date: Gni CONST UCTION 4/24/2014 DATE prS B The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2014-04-24701:22:26 ID: LQ042114 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 U CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoft Job Number ID: LQ042114 User Number 5732 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. KLEIN'S - Casita Addition Building Type la Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 1412412014 Date Project Address 81307 JASMINE CT La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 523 Addition 268 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 255 Perim = 0' Existing Wall Wood Framed R-13 391 Existing Roof Wood Framed Attic R-38 255 Existing Slab Unheated Slab -on -Grade None 268 Perim = 0' New Wall Wood Framed R-15 391 New Roof Wood Framed Attic R-38 255 Radiant Barrier New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Right (IM 48.0 0.340 0.33 none none Bug Screen Removed Rear (S) 8.0 0.340 0.33 none none Bug Screen Existing Right (IM 18.5 0.340 0.33 none none Bug Screen Existing Front (N) 6.0 0.340 0.33 none none Bug Screen Existing Right (KO 15.0 0.390 0.37 none none Bug Screen Existing Right (lM 3.5 0.390 0.37 none none Bug Screen New Rear (S) 8.0 0.390 0.37 none none Bug Screen New Rear (S) 24.0 0.360 0.35 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented -6.0-Existing-, I G VTY ()1 LA QUIN'TA N I Fit m n4UG & SAFETY DEPT. WATER HEATING ( z)oF v��r Qty. Type Gallons Min. Eff Distribution`I t=�l� �(`(1�14TF�t t(�T'?44US I Irl/�TC QV EnergyPro 5.1 by Ener Soft User Number: 5732 Run Code: 2014-04-24T01:22:26 ID: LQ042114 Page 3 of 11 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Mr. & Mrs. KLEIN'S - Casita Addition Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1412412014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Furnace Default FAU/AC 2006 and Later has an AFUE less than the Vintage Defaults. Field verification is required. HIGH MASS Design - Verify Thermal Mass: 255.0 ftz Exposed Slab Floor, 3.500" thick at Existing HIGH MASS Design - Verify Thermal Mass: 268.0 ft2 Exposed Slab Floor, 4.000" thick at Addition The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. F—cnw OF LA QUINT - BUILDING & SAi-C j Y UC -r- Y . F-nR CONSTRUCTION EnerqyPro 5.1 by EnerSoR User Number: 5732 Run Code: 201404-24701:22:26 ID -LL -Q0421'14 r Page 4 of 11 PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. & Mrs. KLEIN'S - Casita Addition ❑ Multi Family m Existing+ Addition/Alteration 4/24/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 7.80 1.96 5.84 Space Cooling 142.63 129.44 13.18 Fans 31.78 28.58 3.19 Domestic Hot Water 22.29 22.29 0.00 Pumps 0.00 0.00 0.00 Totals 204.49 182.28 22.21 Percent Better Than Standard: 10.9% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 135 6 Fuel Available at Site: Natural Gas (E) 0 0 Raised Floor Area: 0 (S) 423 40 Slab on Grade Area: 523 (M 306 37 Average Ceiling Height: 9.0 Roof 510 0 Fenestration Average U -Factor: 0.36 TOTAL: 83 Average SHGC: 0.35 Fenestration/CFA Ratio: 15.9% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Santiago Lopez-Ocampo Address P.O. Box 1018 Name 4124/2014 City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance -using ductldesign, duct sealing, verification of refrigerant charge, insulation installationequality,, and building envelbpd seali, dg require installer testing and certification and field verification by an approved HERS rater- DEPT. EA' B8,"� �..,1301-DING Designer or w ter (per Business & Professions Code) —, �/ o V �=D Company P .p i'r �" mSTRUCTiON Address Name FOR Cr I� City/State/Zip Phone Signed License #—� Date —n-rP --BY Ener Pro 5.1 by EnerqySoft User Number: 5732 RunCode: 2 014-04-24 701:22:26 ID: L 042114 Pa e 5 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. KLEIN'S - CBsite Addition Building Type m Single Family ❑ Addition Alone 11 Multi Family m Existing+ Addition/Alteration Date 4/24/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 255 0.730 None 0 180 Existing 4.4.7-A 1 Existing Wall 105 0.102 R-13 270 90 Removec 4.3.1-A3 Existing Wall 127 0.102 R-13 180 90 Existing 4.3.1-A3 Existing Wall 135 0.102 R-13 270 90 Existing 4.3.1-A3 Existing Wall 129 0.102 R-13 0 90 Existing 4.3.1-A3 Existing Roof 255 0.025 R-38 0 0 Existing 4.2.1-A21 Existing Slab 268 0.730 None 0 180 New 4.4.7-A1 Existing Wall 135 0.095 R-15 270 90 New 4.3.1-A4 Existing Wall 136 0.095 R-15 180 90 New 4.3.1-A4 Existing Wall 120 0.095 R-15 180 90 New 4.3.1-A4 Existing Roof 255 0.025 R-38 0 0 New 4.2.1-A21 Existing FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 48.0 0.340 NFRC 0.33 NFRC 270 Removed (e) Double Non Metal Clear Existing 2 Window 4.0 0.340 NFRC 0.33 NFRC 180 Existing (e) Double Non Metal Clear Existing 3 Window 4.0 0.340 NFRC 0.33 NFRC 180 Existing (e) Double Non Metal Clear Existing 4 Window 15.0 0.340 NFRC 0.33 NFRC 270 Existing (e) Double Non Metal Clear Existing 5 Window 3.5 0.340 NFRC 0.33 NFRC 270 Existing (e) Double Non Metal Clear Existing 6 Window 6.0 0.340 NFRC 0.33 NFRC 0 Existing (e) Double Non Metal Clear Existing 7 Window 15.0 0.390 NFRC 0.37 NFRC 270 Existing Milgard Classic Low -E Vinyl Existing 8 - Window 3.5 0.390 NFRC 0.37 NFRC 270 New Milgard Classic Low -E Vinyl Existing 9 Window 4.0 0.390 NFRC 0.37 NFRC 180 New Milgard Classic Low -E Vinyl Existing 10 Window 4.0 0.390 NFRC 0.37 NFRC 180 New Milgard Classic Low -E Vinyl Existing 11 Window 24.0 0.360 NFRC 0.35 NFRC 180 New Jeld-Wen, Steel Fr. Dr. Existing (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 lBuq Screen 0.76 11 Bug Screen 0.76 A 01 111, tip I i�r) I ' FOR GUNj I r b , ivyi Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2014-04-24 701:22:26 ID: LQ0p,2114 _ I Pa e 6 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. & Mrs. KLEIN'S - Casita Addition Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/24/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC System Existing 255 2,295 2000 Addition 268 2,412 Totals 1 268 255 01 0 HVAC SYSTEMS S stem Name Qty. I Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Rinnai REU-VA2024WD ( 1 Instant Gas Kitchen Pipe Ins 150,000 0 0.83 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 0 m Q En -----System Narne — Pipe –Len th--Diameter Pipe Insul. Thick. Qty. HP Plenum Outside Buried El , -� n r- 14 r 1 1!1'-J 11A A . -., - —1— 1-r rV/ r"w7UT I El Dt1i>✓L/�IV�:: w vi . "yy + �nr� r`t !t\tCTRI I ^TIQN Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2014-04-24T01:22:26 ID: LQ042114 I Pa e 7 of 11 DATE t3Y MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date Mr. & Mrs. KLEIN's - Casita Addition 4/24/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed desi n labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, -moisture, eui ment maintenance,- and •wind. -I §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includesa vapor,retardant'or is enclosed entirely in i:j'I conditioned space. """ f a. n ' '_, 150(j)4: Solar water -heating systems and/or collectors are certified b the Solar Rating and Certification Cor oration I FOR CONS FRUCTION EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2014-04-24701:22:26 ID: LQ042114 Page 8 of 11 DATE BY MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. & Mrs. KLEIN's - Casita Addition 4/24/2014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings. shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause de radation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shallmeet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures:§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable .requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. CITE( OF LA QU6NTA BUILDING & SAFETY DEPT. EnergyPro 5.1 by EnergySoft User Number 5732 Run Code: 2014-04-24 TO 1:22:26 run %1DAQ042114J%--4' Page 9 of 11 DATE BY-] MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Mr. & Mrs. KLEIN's - Casita Addition 4/24/2014 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomicaltime clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. LA 0U NTTA MC!TYF &-gSAFETY DEPT._intOV L' DOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2 01 4-04-24 701:22:26 ID: LQ042114 Pgge 10 of 11 I -"-by i HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. & Mrs. KLEIN'S - Casita Addition Date 4/24/2014 System Name HVAC System Floor Area 523 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 529 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 0 10,124 918 168 6,381 Total Output Btuh 0 0 Output Btuh/s ft 0.0 691 368 Cooling System 0 0 Output per System 1 0 0 0 0 Total Output Btuh 1 0 918 0 Total Output Tons 0.0 691 368 Total Output Btuh/s ft 0.0 Total Output s ft/Ton 6,276,000.0 11,506 1 7,117 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow (cfm) 0 Default FAU/AC 2006 and Later 1 0 0 Airflow cfm/s ft 0.00 Airflow cfm/Ton 0.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 0 0 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 67 °FFEI 4 AK 67 OF 105 OF I Heating Coil �-� H I I- L-- 104 OF ROOM 68 of COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 77 / 63 OF 77/63°F 55/54°F ........... Cooling Coil __.. 1 57 / 55 OF 50 Q! ROTO � CITY OF BUILDING & lS!AIFETY DEPT. 75/63 OF FOR CONSTRUCTION EnergyPro5.1 by EnergySoft User Number: 5732 RunCode: 2014.04-24701:22:26 ID: LQ042114 (Page 11 of 11 DATE BY I