Loading...
08-0597 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: - 08-00000597' Property Address: 81392 JOSHUA TREE CT APN: 764-280-999-134 -300236- Application description: DWELLING - SINGLE FAMILY Property Zoning: MEDIUM HIGH DENSITY RES Application valuation: 239845 T4b't BUILDING & SAFETY DEPARTMENT BUILDING PERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/11/08 Owner: SHEA LA QUINTA C/O JEFF MCQUEEN DETACHED 8800 N GAINEY CENTER 350 SCOTTSDALE, AZ 85258 Contractor: Applicant: Architect or Engineer: SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA, CA 9 (760) 777-6005 Lic. No.: 6722 -------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License lass B License No.: 672285 uat ractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s)- licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: i LQPERn1IT �A-]Y O5 2008 WORKER'S COMPEN ISZ(1_WEPrA1_f0N I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers pensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. YI have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier AMERICAN HOME ,Policy Number CA 1593364 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should b come subject to the workers' compensa ' n provisions of Section � 'L1��kNpplicant:4WWL-4—^—� 3700 of the Labor Code, 1 s all f rthwit fSempI _it rhos rovisi at8' e: -- WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and co my dinances and state laws relating to building constru .on, and hereby authorize representatives at�of thi u y to nter upon the above-mentioned property for inspec o purposes. i ature (Applicant or Agent): �Ra Application Number . . . . .. 08-00000597 Structure Information SFD PLAN 6420B W/CASITA, MBR&.NOOKBOX BAY ----- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . DWELLG/LODGING/CONG <=10 Other struct info CODE EDITION 2001 # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 615.00 PATIO SQ FTG 323.00 NUMBER OF UNITS 1.00 --------------------------------------------------°-------------------------- 1ST FLOOR SQUARE FOOTAGE 2781.00 Permit BUILDING PERMIT Additional desc . Permit Fee . . 1129.50 Plan Check Fee 734.18 Issue Date Valuation . . . . 239845 Expiration Date 10/08/08 Qty Unit Charge Per Extension BASE FEE 639.50 140.00 3.5000 -------------------------- THOU BLDG 100,001-500,000 -------------------------------------- 490.00 ------------ Permit . . MECHANICAL Additional desc . Permit Fee 83.50 Plan Check Fee 20.88 Issue Date . . . . Valuation . . 0 Expiration Date 10/08/08 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA .MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee ..•. 124.64 Plan Check Fee 31.16. Issue Date Valuation . . . . 0 Expiration Date 10/08/08 Qty Unit Charge Per Extension. BASE FEE 15.00 2781.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 97.34 615:00 .0200. ELEC GARAGE OR NON-RESIDENTIAL 12.30 E LQPER.NIIT r• LQPER�4IT Application Number . . . . . 08-00000597 ---------------------------------------------------------------------------- Permit . . . PLUMBING Additional desc . Permit Fee . . . . 177.00 Plan Check Fee 44.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/08/08 Qty Unit Charge Per Extension BASE FEE 15.00 18.00 6.0000 EA PLB FIXTURE 108.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 • 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00 Permit _ . . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/08/08 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD -.Plan 6420A Lot 134 w/casita (255 sqft), Box Bay@ MBR (26 sqft) & Bay Nook(23 sqft), 2781 S.F. Permit does not include block wall, pool or driveway approach. 2007 CBC, CMC, CPC, 2004 CEC, 2007 ENERGY CODES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 99.61 DIF COMMUNITY CENTERS -RES 74.00 s DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE • - 73.42 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE '.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 23.98 DIF STREET MAINT FAC -RES 67.00 • DIF TRANSPORTATION - RES 1930.00 Application Number . . 08-00000597 Fee summary Charged Paid Credited Due Permit Fee Total 1529.64 _00 .00 1529.64 Plan Check Total 830.47 .00 .00 830.47 Other Fee Total 4672.01 .00 .00 4672.01 Grand Total 7032.12 .00 .00 7032.12 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING This CF -411 Issued by CaICERTS@ is for the home located at: Certificate Number: Date Inspected: Ca10ERTS Rater: HERS Analyst: Builder/ Developer: Project: Phase: Plan Name: Lot Number: CC3-1798438311 October, 16 2008 William Irvine CC2004075 Chinh Nguyen Shea Homes, Inc. Trilogy in La Quinta (658) New Phase 6420 6134 Specifics about this home: General Information Conditioned Floor Area: 2503 Square Feet Conditioned Volume: 25030 Cubic Feet Front Orientation: Cardinal Number of Stories: 1 Heating and Cooling Systems Passed Heating Equipment: Furnace:'0.8 Cooling Equipment: ACSplit: 14.0 Heating Equipment: Furnace: 0.8 Cooling Equipment: A/C: 14 HVAC Air Distribution Duct Location: Attic Duct Insulation R -Value: 6.0 Water Heating System Proposed QTY Size I Fuel EF Distribution 1 1 50 Gas 0.62 Standard Water Heating System Actual QTY Size Fuel EF Distribution 1 50 1 Gas 1 0.62 1 Standard CF -4R October, 28 2008 81392 Joshua Tree Court La Quinta CA, 92253 Testing & Verification Results Sample # 97726 Main System HVAC System Duct Sealing Passed Installation of -Thermostatic I Expansion Valve (TXV) passed High Energy Efficiency Ratio (EER) Passed High Quality Insulation Installation Passed New System HVAC System Duct Sealing Passed Installation of Thermostatic I Expansion Valve (TXV) High Energy Efficiency Ratio (EER) High Quality Insulation Installation passed Passed Passed The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the CaICERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CalCERTS - Customer Service 31 Natoma St Suite 120, Folsom, CA 95630.