08-0602 (SFD)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 08-00000602
Property Address: 81462 JOSHUA TREE CT
APN: 764-280-999-129 -300236-
Application description: DWELLING - SINGLE FAMILY
Property Zoning: MEDIUM HIGH DENSITY RES
Application valuation: _ 150034
Applicant:
E
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
SHEA LA QUINTA
C/O JEFF MCQUEEN
DETACHED 8800 N GAINEY CENTER 350
SCOTTSDALE, AZ 85258
Architect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and P ofessionaI Code, and my License is in full force and effect.
License la : 13 License No.: 672285
at ntract.,:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury thavI am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5. Business and Professions Code:. Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License' law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( I I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
v
LQPER,\IIT
Contractor: rJ
SHEA HOMES, INC.
81260 AVENUE 62
LA QUINTA, CA 92253
(760)777-6005
Lic. No.: 672285
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/11/08
MAY o,5 200D
I
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier AMERICAN HOME Policy Number CA .1593364
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
"and agree that, if I should becomes 'ect to the workers' compensation provisions of Section
0 of the Lab Code, I shall fort nth comply with those provisions.
pticant:
WARNING: FAI URE TO SECURE ORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($ 100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
.2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and c unt ordinances and state laws relating to building construction, and hereby authorize representatives
Of 05 ty enter upon the above-mentioned property for ins ction purp S.
lea, ignature (Applicant or Agent):��.
Sa:
Application Number .
. . . . 08-00000602
Structure Information
Construction Type . .
. . . TYPE V - NON RATED
Occupancy Type . . .
. . . DWELLG/LODGING/CONG <=10
Flood Zone . .
. . . NON -AO FLOOD ZONE
Other struct info . .
. . . CODE EDITION
2001
# BEDROOMS
3.00
FIRE SPRINKLERS
NO
GARAGE SQ FTG
576.00
PATIO SQ FTG
177.00
NUMBER OF UNITS
10.00
-------------------'---------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
1688.00
Permit . . .
BUILDING PERMIT.
Additional desc .
Permit Fee . . . .
818.00 .Plan Check Fee
531.70
Issue Date
Valuation . . .
. 150034
.Expiration Date
10/08/08
Qty Unit Charge
Per -
Extension
BASE FEE
639.50
51.00 3.5000
------------------------ -----------------------------------------------------
THOU BLDG 1.00,001-500,000
178.50
Permit . . .
MECHANICAL
.Additional desc .
Permit Fee . .
64.00 Plan Cberk Fee
16.00
Issue Date . . . .
Valuation . . .
. 0
Expiration Date
10/08/08
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2.00 9.0000
EA MECH FURNACE <=100K
18.00
2.00 9.0000
EA MECH B/C <=3HP/100K BTU
18.00
1.00 6.5000
EA 'MECH VENT FAN
6.50
1.00 6.5000
----------------------------------------------------------------------------
EA MECH EXHAUST HOOD
6.50
Permit . . . . . .
ELEC-NEW RESIDENTIAL
Additional desc .
Permit Fee
85.60 'Plan Check Fee
21.40'
Issue Date . . . .
Valuation . . .
. 0
Expiration Date
10/08/08
4 Qty Unit Charge
Per
Extension
BASE FEE
1.00
5
1688.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
59.08
LQPI%W�1I'f
1;,
Application Number 08-00000602
Permit . . . . ... ELEC-NEW RESIDENTIAL
Qty Unit Charge Per
Extension
576.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL
----------------------------------------------------------------------------
11.52
Permit . . . PLUMBING
Additional desc .
Permit Fee . . . . 128.25 Plan Check Fee
32.06
Issue Date . . . . Valuation . . . .
0
Expiration Date 10/08/08
Qty Unit Charge Per
Extension
BASE FEE
15.00
10.00 6.0000 EA PLB FIXTURE
60.00
1.00 15:0000 EA PLB BUILDING SEWER
15.00
1.00 7.5000 EA PLB WATER HEATER/VENT
7.50
1.00 3,.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
5.00 17500 EA PLB GAS PIPE >=5
3.75
1.00 15.0000 EA PLB GAS METER
----------------------------------------------------------------------------
15.00
Permit . . . GRADING PERMIT
Additional desc .
Permit Fee 15.00 Plan Check Fee
.00
Issue Date . . . . Valuation . . . .
.0
Expiration Date 10/08/08
Qty Unit Charge Per
Extension
BASE FEE.
15.00
------------------------=---------------------------------------------------
Special Notes and Comments
SFD - LOT 129, Plan 4520A 1688 SF/
BOX BAY @ MASTER (26SF) & 4' EXT. GARAGE
(88SF).PERMIT DOES NOT INCLUDE POOL,
SPA, BLOCK WALLS OR DRIVEWAY APPROACH.
2007 CBC, CMC, CPC, 2004 CEC, 2007
ENERGY CODES
-----------------------------------------------------------------------------
Other Fees . . . . ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER --RES
995.00
ENERGY REVIEW FEE
53.17
DIF FIRE PROTECTION -RES
140.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
355.00
' DIF PARK MAINT FAC-- RES
22.00
LQPERMIT
J
Application Number
. . . . .
08-00000602
----------------------------------------------------------------------------
Other Fees . .
. . . .
DIF PARKS/REC - RES
892.00
STRONG MOTION (SMI) - RES
15.00
DIF STREET MAINT FAC -RES
67.00
DIF TRANSPORTATION - RES
1930.00
Fee summary
Charged-
Paid Credited
Due
Permit Fee•Total
1110.85
.00 00
1110.85
Plan Check Total
601.16
.00 .00
601.16
Other Fee Total
4543.17
.00 .00
4543.17
Grand Total
6255.18
.00 .00
6255.18
r
CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING October, 28 2008
This CF -4R Issued by CaICERTS@ is for the home located at:
81462 Joshua Tree Court
Passed
Installation of Thermostatic I Expansion Valve
La Quinta CA, 92253
Certificate Number:
CC3-1798438306
High Energy Efficiency Ratio (EER)
Date Inspected:
October, 21 2008
Passed
CaICERTS Rater:
William Irvine
HERS Analyst:
CC2004075
Chinh Nguyen
Builder/ Developer:
Shea Homes, Inc.
Project:
Phase:
Trilogy in La Quinta (658)
New Phase
Plan Name:
4520
`
Lot Number:
6129
Specifics about this home:
General Information
Conditioned Floor Area: 1688 Square Feet
Conditioned Volume: 15218 Cubic Feet Testing & Verification Results
Front Orientation: Cardinal
Number of Stories: 1 SamDle # 100342
Heating and Cooling Systems
Heating Equipment:
Cooling Equipment:
HVAC Air Distribution
Duct Location:
Duct Insulation R -Value:
Furnace: 0.8
ACSplit: 14.0
Attic
6.0
Water Heating System Proposed
QTY Size Fuel EF Distribution
1 50 Gas 0.62 Standard
Water Heating System Actual
QTY Size Fuel I EF Distribution
1 50 Gas 1 0.62. Standard
HVAC System
Duct Sealing
Passed
Installation of Thermostatic I Expansion Valve
passed
(TXV)
}
High Energy Efficiency Ratio (EER)
Passed
High Quality Insulation Installation
Passed
The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating
considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a
typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only
after the features listed have been verified and approved by the CaICERTS Certified Rater shown above. If you have a concern or
complaint regarding this report of the services used in obtaining it, you may contact: CalCERTS - Customer Service 31 Natoma St
Suite 120, Folsom, CA 95630.