Loading...
13-1044 (SOL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 13-00001044 Property Address: 58703 JEREZ APN: 764-650-010- Application 64-650-010 Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 25000 Applicant: �rtlrL7!{�% 2 Ta�v BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: IJA. Owner: BARTEAUX, RICHARD L D Contractor: HOT PURPLE INC 870 E. RESEARCH DRIVE, # 1 PALM SPRINGS, CA 92262 (760)322-4432 Lic. No.: 940550 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/03/13 OCT 041013 ------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION - ------------------------------•----------------— WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: C46 License No.: 940550 � /7r'7 ^ PURR_ Date: Contractor: �T 1��.,f 1 R _ = (-6(jr::,A?67YI for by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE COMP. Policy Number 9053981-13 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or 3700 of the Labor Code, I shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: - Date: 3 Applicant: , ������F 1 (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and _ the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. oneyear of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of F property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct.,) agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purpos _ Date: K JW-(J��j Signature (Applicant or Agent): F Application Number . . . . . 13-00001044 Permit . . . ELECTRICAL 2013 Additional desc . Permit Fee . . . . 23.83 Plan Check Fee.. .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/01/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC DEVICES, FIRST 20 23.83 ----------------------------------------------- ---------------------------- Special Notes and Comments 10.1kW SOLAR ARRAY - (30) 335W SUNPOWER PANELS W/ (1) 10,000W SUNPOWER INVERTER [510SF]'2010 CALIFORNIA ELECTRICAL CODE. October 3, 2013 4:51:26 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 PLAN CHECK, ELECTRICAL 23.83 PERMIT ISSUANCE M/P/E 90.57 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 23.83 .00 .00 23.83 Plan Check Total .00 .00 .00 .00 Other Fee Total 115.40 .00 .00 115.40 Grand Total 139.23 .00 .00 139.23 0 .LQPERMIT nr-sa Brrr.# ��. City. O[liitta Butkgpg u.Saky Dtvtston P.O. Box 1504,78-493 Calle Tamptco AUG .0 1 2613 � 1.a.Qutnta, CA 92233 - (760) 777-7012 CI1Y LA Building Permit Application and Traclfgt F M Q�rNTq Pertnrt � l�• ltd Project Address: " ?� Owner's Name:. C r A. P. Number. Address: Legal Description: Contractor. City, ST, Zip: � U I tJT^ Telephone: - Pmjeex Description: Address: 020 City, ST, Zip=2LUI145, Telephone: 2'L a .3 A State Lic. # : City Lic l St+N /Oy Vv j irNM{ it+l!► Arch. Eng., Designer. Address: City., ST, Zip: Telephone: ' State Lic. #: � Name of Contact Person: Construction Type:. Occupancy: Project type (circle one): New Add'n Alter Repair Demo ' Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: Z S U APPLICANT: DO NOT WRITE BELOW THIS UNE H Submittal Req'd Recd TRACMG PERM[r FFM - Plan Sete Plan Cheek submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Truss Cates. Galled Contact Person Pian Check Balance Title 24 Calci. Pians picked up Construction Flood plain plan Plans resubmitted.'. Mecharilcal Grading plan 2" Review, ready for correct! le 04 2M Electrical Subeoatactor List Called Contact Person Plumbing Grant Deed Pians picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE-, ''` Review; ready for eorreetlonslissue Developer Impact Pee Planning Approval. Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit Issue School Fees Total Permit Fees 3g. to T4t!t 4 4 4" COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 4 R LEr- IVF— D (760) 777-7125 FAX (760) 777-70111 I i RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAk) S E. D 2 4 13 DATE: AUGUST 19, 2013 STATUS: FIRST REVIEW PLAN CHECKED BY: AJ ORTEGA TELEPHONE NUMBER: (760) 777-7018 ADDRESS: 58-703 JEREZ r�-y `.)F i -H QUTNITA COI4il''iL N'P 1)' DEVELOPMENT DESCRIPTION: PV SOLAR SYSTEM APPLICANT: BARTEAUX/HP ENERGY PLAN CHECK #: This submittal has been checked for compliance with the 2010 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code. APPLICANT: The following items are'being returned to you for correction: 1- SOLAR (REDLINED) PLAN 2- UNMARKED PLAN SET 1- CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: 1- SOLAR (REDLINED) PLAN 1- CORRECTION LIST w/responses 2- REVISED PLAN SETS 1- ASSESSORS SITE/FLOOR PLAN INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall .be per CBC Section 1003," are not acceptable. Show or note syeciiicall►r how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List (SOLAR) Page 1 of 3 SECTION A - GENERAL 1) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code'5536. Resubmittals will not be accepted with signatures missing. SECTION B - SOLAR I. General 1 yReconcile noted information shown on single line diagram. See V review redlined plan. Please provide a response for each item, either on returned redlined plan or in letter. R. Circuit Requirements XIn a do photovoltaic source circuit or output circuit, the maximum photovoltaic system voltage for that circuit rr shall be calculated as the sum of the rated open -circuit voltage of the series -connected photovoltaic modules corrected for the lowest expected ambient temperature. (CEC §690.7) Please provide conductor sizing schedule showing all NEC adjustment factors. PLEBE SEE 1 4Dti'STEE-M VOLTgCaE RATIMCI CALLS. 4 TA13LE (010.? ON SHEET FV - 3.1 The Circuit conductors and Overcurrcnt devices shall be sized to carry not less than 125% of the maximum 01 currents as calculated in 690.8(A). (CEC §690.8(B)1) Array shown does not clearly identify string sizes, additionally please see above correction for required information to be shown on plan. SEE TA5LES LISTED INvEI2TEEZ I RATINEIS ON SHEF-T FV -3.1 III. Disconnecting Means 4-1.7 A ( MAX AG CUIZF-eNT' 1) No corrections apply. X 125 % 52.125A ----) (pC)A IV. Wiring Methods *MATH AND GTR INU SiZeS Ar -E W CLr=AR -r IND fCAT ED f' AS (3)(vAW6+ THWN--Z 101T" rMT w�0 ) (oA 6 TH\AIN-Z .,/'I) Where the number of current -carrying conductors in a raceway exceed;three.(-_'�).the Allowable ampacity of each conductor shall be reduced as shown in Table 310.15(B)(2)(a). (CEC1§31.I S(B)(2))-Adjust accordingly. W 1✓ e�OVl T74 I S ON TH E ( f N V EkTelz 41t I RAT (N6-7) CALLS . 0 EP EET PV - 3.1 .. • TF --1 E TEM P. Co2x?_ECT10N FACTO IS . 82 V. Grounding * GONLDUIT DOES NOT PzUN ALONG tZOOF:_* XSystem grounding, Equipment grounding, Equipment bonding and Array grounding shall be designed and specified on plan per California Electrical Code Article 690, Part V. Fully specify all required information and design on plans - Grounding Electrode Conductor required in addition to Equipment Grounding Conductor. C-7,E.C. AND F_ .U1R (:3iRLUWD1Nb C0NC)UCT0F2.oa4ZG StPEC FIFO ON THE S(N6LE LI NI" plACIRAM - PV -3.0. ALSO SC=E Dl✓TAIL ON kD -4.1 VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts The output of a utility -interactive inverter shall be permitted to be connected to the load side of the service disconnecting means of the other source at any distribution equipment on premises. Where such a connection is made, the interconnection provisions of CEC Section 690.64(B)(1) through (B)(7) shall apply. If de -rating is required, please provide load calculation for the entire dwelling complying with the provisions of Article 220. PLEASE SEE LOAUP eALCUL-A"T ION ON S HF_: FV -�j, -VW I%YVW �,,� I2) `1�9t7 1 Residential Plan Check Correction List (SOLAR) Page 2 of 3 r� City of La Quinta SECTION C - STRUCTURAL 1f} Revise support spacing to be a maximum of four (4) feet on center or provide engineering to justify point Ioading at six (b) feet on center. SR UPPOT SPAC( NG �-bdl5 BEeN 2�VjGeC) r -W r 010,c . D.G. 7() `b. C. - SEE NOrEF Oto FV -Z-0 J4 FZE V159r-) PGTA! L ON RID - 4 o SECTION D - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 3 of 3 L 11 DALW R AT CORA4 MOUNTAIN July 19, 2013 RECE/ V ED-' Mr. Richard Barteaux AUG 01 58-703 Jerez 2013 La Quinta, CA 92253 COMM N OF LA QVINTq TY DEVELOpMENT RE: 58-703 Jerez Dear Mr. Barteaux: This is to confirm that request for approval of the Installation of Solar Panels has been approved by the Design Review Committee. Your request dated Ju17 17, 2013 is approved as indicated on the plans you submitted. We will be depositing the non refundable processing fee of $400 on Monday. Instead of the $2;500 refundable deposit check provided; since the contractor you are using is new to the association, please have him provide his contractors license number, workers comp, liability, and auto insurance paperwork to the HOA office. After receipt of these document, we will return the check to them. Please contact me if you have any questions or concerns about your application. Sincerely, ANDALUSIA AT CORAL MOUNTAIN ASSOCIATION Dennis Byerly. Association Manager ANDALUSIA Architectural Deposit Receipt XHOA Date: Owner: 6 Property Address: Account No. Please deposif clieck(s)to the following Operating Account foi-MA: HOA Deposits: ❑ Refundable Construction Deposit Amount $ Check #: Non -Refundable Fee Amount $ qW Check #: 51_IZ :Roq 7' Date Check sent to Corporate: f I Andalusia Staff member: Initials ----------- Architectural Committee inspected property afte=Deposit , Date and directed staff to: Refund Deposit Describe circumstances for deposit being withheld and written notice to the owner must be sent ASAP advising what must be done to receive deposit back: Andalusia Staff member: Date Letter sent: Initials When refund check has been cut/signed, a copy is to be attached to this form and filed in the unit file. Revised 07.28.08 C:\Documents and Settings\sbadham\Local Settings\Temporary Internet Files\OLK28\Andalusia Architectural Deposit Form_BLANK.docx HOT PURPLE ENERGY P.O. BOX 261 PALM SPRINGS CA 92263 5112 1' PACIFIC MEMIEP, I: 901 L rk ITLGMMN WAY B A N K �R[l�66Jfta- 9ALN SrPINCS, CAYII67 r;6o-mm4 760.322.4433 7/17/13 x a G 0 '9 PAY TO THE Andalusia at Coral Mountain Association $ '''400.00 ° ORDER OF H Four Hundred. and 00/100.....,,....,.«......:.......................................................#......,,...,.....,., DOLLARS u Andalusia at Coral Mountain Association Design Review Committee 8 c/o Andalusia Sales Pavillion 81-565 Carboneras MEMO La Quinta, CA 92253 oAizEosIGNATUAe Richard Barteauz, 58703 Jerez 112005L1211, .1: Hot Purple Energy Andalusia at Coral Mountain Association 7/17/13 Cost of Goods Sold: Engineering Richard Barteauz, 58703 Jerez .Pacific Premier Gener Richard Barteauz, 58703' Jerez 5112 400.00 400.00