Loading...
BWFE2015-0026aw 78-4135 CALLE TAMPICC LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: Property Address: APN: Application Description Property Zoning: . Application Valuation: Applicant: ULRICH SAUERBREY B W FE2015-0026 55766 ISLEWORTH 775370016 150 LF OF COMBO WALL $9,375.00 JAN 2 8 2015 CITY OF LA QUINTA LICENSED CONTRACTOR'S DECLARATION% I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and P fessions Code, and my License is in full force and effect. License ass: B % License No.: 927267 Dater t Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt fro the Contrac or's State License Law for the following reason (Sec. 7031.5, Business an ofessi s Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500):: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Ad VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/28/2015 Owner: LQR GOLF 1 BUSH ST STE 1100 SAN FRANCISCO, CA 0 Contractor: CALIFORNIA WEST CONSTRUCTION 1 5927 PRIESTLY DRIVE STE 110 CARLSBAD, CA 92008 (760)918-6768 LIC. No.: 927267 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance oft k for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Sectio 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should beco a sub' ct to the workers' co ensation provisions of Section 3 0 o the L or Code, I hall forthwith comply with hos/ee provisions. Dat~ 1 0 Applicant:40 WARNING: FAILURE TO SECURE WORKERS' COMPENSATIO COVEJOVILES LAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIE D UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon w.iose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating topuilding construction, and hereby authorize representatives of this ity to enter u on t e above mentioned property for inspection purposes. Date, Signature (Applicant or Agent): FINANCIAL 1 • DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - EA ADDITIONAL 50 LF 101-0000-42404 0 $62.36 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $60.91 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for FENCE OR FREESTANDING WALL $171.13 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RET WALL<=12 - EA ADD 50 LF 101-0000-42404 0 $14.50 $0.00 t PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RET WALL <=12 - FIRST 100 LF 101-0000-42404 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RET WALL <=12 - FIRST 100 LF PC 101-0000-42600 0 $60.91 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for RETAINING WALL $123.27 $0.00 TOTALS:4i $0.00 Description: 150 LF OF COMBO WALL ADDITIONAL Type: WALL/FENCE Subtype: Status: APPROVED Applied: 1/12/2015 SKH Approved: 1/28/2015 SKH Parcel No: 775370016 Site Address: 55766 1SLEWORTH LA QUINTA,CA 92253 Subdivision: TR 29421 Block: Lot: 31 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $9,375.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 STEPHANIE KHATAMI Details: 150 LF OF COMBO WALL PER APPROVED DETAIL. 2013 CALIFORNIA BUILDING CODES. Printed: Wednesday, January 28, 2015 10:01:01 AM 1 of 3 Cg? NAf SWZTFAAA ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE _ STAFF NAME. ACTION DATE COMPLETION DATE NOTES E-MAIL STEPHANIE KHATAMI 1/12/2015 1/12/2015 PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 1/8/2015 1/8/2015 RECEIVED CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT ULRICH SAUERBREY CONTRACTOR CALIFORNIA WEST CONSTRUCTION 1 5927 PRIESTLY DRIVE CARLSBAD CA 92008 STE 110 OWNER LQR GOLF 1 BUSH ST STE 1100 SAN FRANCISCO CA 0 Printed: Wednesday, January 28, 2015 10:01:01 AM 1 of 3 Cg? NAf SWZTFAAA PARENT PROJECTS REVIEWS Printed: Wednesday, January 28, 2015 10:01:01 AM 2 of 3 (cmW SY.[TFM.S FINANCIAL INFORMATION REMARKS NOTES CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 0 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: WALL/FENCE - EA 101-0000-42404 0 $62.36 $0.00 0 FINAL" ADDITIONAL 50 LF 0 1 BOND BEAM WALL/FENCE - FIRST 101-0000-42404 0 $47.86 $0.00 100 LF WALL/FENCE - FIRST 101-0000-42600 0 $60.91 $0.00 100 LF PC Total Paid for FENCE OR FREESTANDING WALL, $171.13 $0.00 RET WALL <=12 - EA 101-0000-42404 0 $14.50 $0.00 ADD 50 LF RET WALL <=12 - FIRST 101-0000-42404 0 $47.86 $0.00 100 LF RET WALL <=12 - FIRST 101-0000-42600 0 $60.91 $0.00 100 LF PC Total Paid forRETAiNING WALL $123.27 $0.00 TOTALS:4i $0.00 PARENT PROJECTS REVIEWS Printed: Wednesday, January 28, 2015 10:01:01 AM 2 of 3 (cmW SY.[TFM.S REMARKS NOTES SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE INSPECTIONS COMPLETED DATE RESULT 0 FOOTINGS AOR 0 FINAL" 0 1 BOND BEAM PARENT PROJECTS REVIEWS Printed: Wednesday, January 28, 2015 10:01:01 AM 2 of 3 (cmW SY.[TFM.S REVIEW TYPE I REVIEWER - I SENT DATE - I DUE DATE 1—WDATEURNED I STATUS I REMARKS I NOTES Printed: Wednesday, January 28, 2015 10:01:01 AM 3 of 3 CR CY.CiFMt CITY OF LA Q BUILDING & SAFE AP�PR �u FOR o DATE ' 6-y- N 5' TO DAYLIGHT uj �—�--= 2" CAP Aeric mcr�saoavMmrstccAcn�sArs7raAc oawzrr>: atoa; San: mv�miL ro Asrw c an a uR• aea #4 VERT BAR 0 32" !�K.¢7;( "�S70c2 OIC 0 CENTER OF QWUrs7PBVW70eP11rooDQMXAWAMC4X FOMMCMKXE7E Itti0FRMN.. WldM WAnR4V BVrPARO 6" CMU W/ 24" MIN. » ' FAWarM PPaMa%VF0AAWfWnWusr EXT. INTO 8" CMU AaWdr""'"s= BELOW. IMMEUMMM UL' Lbt'M"WQ74MAMe1010=eVOD7C"W0F = Bvov,9L /ROWCAAS7N Wl "'GWMYAMMMUS917MAL WA7MAWWA407==f O° MALL WOOP 1VA7VWMP*0A BOUAL LEVEL BACKFILL' DJWGN CRrrBUAr AFR 2013 CIBC I.Si01LBFAUWPR135M-25WP5F. EQXVAL9YTR.UID APeZW a A0 PSFPER SUBS PUMT 2. ALLOWABLELAMM PASMT AVMURE-150 PSP. _ 3. GMOUTSmsvGw - 2=PS7V m A4Y5. & 1500 PST M450MYCOMPRESA17 M.. ON -1 f4 HORZ CONT. 0 24 0/C 8816 CMU SOLID GROUTED W/SPCL. INSPECTION REOD. 'G' BAR 0 EDGE OF i— B" CMU FULL HEIGHT NOTE: PROVIDE LEVEL ONE SP Z4L INSPECT70N PER CBC TABLE 1704.5.1 OF 7HEM4SONRYSTEM PRIOR TO GROU77NG 70 VERIFY GRADE; S17EAND PROPER PLAC E04ENT OFRUNFORCMENTAND 70 ENSURE THE GROL?SPACE5 THE PROPER SIZE WITHOUT ORML C77ON 07HER THAN NORMAL MORTAR FINS. (2) # 4 HORZ. CONT. 0 24" 0/C PGA WEST/LA QUINTA F' DOWELS 0 EDGE TR. NO. 36537 OF 12" OR 8" CMU 12816 CMU SOLID GROUTED W/ SPCL. INSPECTION REOD. D D F 1P W 1 'A '. IA, S R 35 PER P E/ 12 OF 3/4' GRAVEL WRAPPED W/ MIRAFI IRON I 'C' ;. e . �._. •.••e r1 •.' fIL7ER FABRIC -EXTENDING UP TO 12" OF FIN/SH GRADE — 2% SLOPE TO DRAIN �✓ 'G' VER T PROND£ OUTLETS 0 100' INTERVALS 2'-0' 2'-0'" QR E, ' N/A H' BARS` /• 0032"'01c f__ 14 HORZ. CONT. 0 12.0/ 2"O/C v C I b 12". 0 TOP & BOTTOM OF w V 2'-8' F0071NG 412"l N/A 2'-9' * f ,-20lAt. , NIA ` ; P CAL%* . 'A '. 'B' I 'C' 'D' 'E' 'F' D 0 WEL 'G' VER T 'H' BAR 2'-0' 2'-0'" N/A 2'-6" N/A #4®32" 01C EY N/A 0032"'01c f__ 12". 6. . 2'-8' 2'-8" N/A 2'-9' N/A #4®32" 0/C 41' NIA 4®32" 0/C �_ 12'4 6" 3 —4 3'-4" N/A 3'-0" N/A #4®32" O/C 4g N/A 4®32" 0/C 12NL 6"f 4'—.0' 4'-0" N/A 3'-3" 4" #4®16" 0/C157' N/A 4®16" 0/C r 12"L 6. 4'-8' 4'-8" N/A 3,_6!! 6!! #4®1s" o/�65' N/A 5®16" DIC f _. 1 12N 6N 5'-4`5,-4,! N/A J'-9" 9" #5@16" o/C 73' N/A 5616" o/c : 12"L 6'. 6'– 10„ #5@1s" o/C #4®16O/C " o/C F_0. 5®16�r2'-0'4'-3 L3 12 6" COMBO RETAINING WALL PER SECTION J J, K -K AND UPPER. WALL ON SECTION I -I. RETAINING WALL NOTES: MATERIALS. 8. WALLSSHOULDBEGROUTEDAT4'HEIC4T1NTERVALS. CONTRETE• Pc a 4000 PSI * 28 DAYS W/ 0.50 WATERICEMEIVT RATIO. GROUTING SHOULD REPERFORMED AS SOONASPOSSIBLE REINFORCENGSTEEL: ASMA-615 GRADE 60, AFTER THE CONOWTFMASONRYUNITSARE PLACED . CONCRETE MASONRYULVITS: A57MC90 MORTAR: USE OBP TYPES PER A57M C270 9. 'PROVIDE CONTROL X NTSAT 40'01C MAX. GROUT.•. USE 2000 PST 28 DAYS PER ASTM C 476. CDMEN> PoRTTAND CLEMENT PER AWN C-150 TYPE HIV 10. BUILDING DEPARTMENT INSPEG770N SHALL BE OF THE FOLLOWING STEPS. 15t FOUNaMON 7REN0'f WITH SECURED REINFORCING STEEL GENERAL NOTES: 2nd. BLOO(WALL WITH RLINFORaNGSTEEL affVREGROUT. 31d. MID•HQGHT GROUTING FOR WALLS OVER 4' MGH. 1. ALL MATERIALS, PRODLX75, WORMENSHIP, TE577NGAND 4th. GROUTED WALL AND DRAM4GESYMER INSPECTION SHALL COMPLYWI7H 7NE2013 =- 5th. 840107LL AND FINAL 2 ALL )0077NG5' SHALL sE POURm ON UNDISTURBED NATURAL Sl. OMIT HEAD IOINTSAT FIRST COURSEAT EWAY32" 0/C WITH GROUND OR ON UNDISTURBED ENGINEERED FILL 1 CV. FT. OF -/ "GRAVEL FOR WEEPHOLE WHEN THE WALL IS LESS TW PGH, I WALL SHALL HE LAID 7RUEAND PLUMB, AND ALL CELLS SHAM BE GROUTED SOLID. 12 PROVIDE 4"e SDR 35 PERFORATED PIPE WITH PERFORATIONS DOWNAT I % MIN. SLOPE WITH 1 a. OF3/4" GRAVEL 4. ALL SPLICES SMALL BE 48 LIAR DIAMETERS. WRAPPED WITH MIRAFI 14ON FILTER FABRIC OR EQUAL 84L7C DRA/NAGESYSTEM SHALL HAVE 7EECONNEC7701V AND NON - S. ALL VERTICAL AND HORIZONTAL BARS SHALL BE 77ED PfRF0RA7ED 2"e OUTLET PIPEATEVERY 10' O/C THROUGH TOGETHER. THE WALL AT 2 % SLOPEABOVE THE FINISHED SURFACE 6. DO NOT USE HEAVY COMPACT70N EQUIPMBVTADIACENT TO THE WALL THE OWTRACTOR SHALL BERESADNSIBLEFOR ANYDAMAGfS 70 THE WALL RESUL77NG FROMINAPPROPRIAM COMPACTION MNIQUES AND EQUIPMENTS 7. THERETAIMNG WALLS SHALL NOT BE MMOL LIED UNTIL AT LEAST 14 DAYS -UNLESS PROPER SHORINGLSPROWDm NATURAL SiDD =AACTED Fl I CONTROL JONr AM WALL W/RUNFORQNG PER DETAILS 04 HORZ C01M 0 TOP AS REI jUt "- _. PR0VWE24"MIN. LAPAND MAOVTATN3' GEAR nm SOIL Q •. v d b . Q Q• D •Q I I'I I I:. III J. !'4 HORL CW.. * B TTW - PROVIDE24' NN. LAP AND MAINTAIN 3" OFAR FROM SOIL FOOTING STEP DETAIL 0 ~ C31925 N ExP.l2-31-2014 *, Jr4 C .Op C �I Use menu. item Settings > Printing & Title Block Title 2'0" retain w 6' wall 110 85c wind Page: to set these five Ilnes of Infbrmation Job # ...New... Dsgnr: Date: 18 SEP 2014 for your program. Description.... This Wall In File: c:\users\tmallis\documents\retainpro 117 project. files\pga,west tr 36537 signature ' RetilnPro 10 (c)1:987 2014; B.u11d 10.14.8.13 Lleense-01jOR5 4916LOCK COMPANY. INC. Cantilevered Retaining Wall Design :ode: CBC 2013,ACI 318-11,AC1 530-11 License o : O Criteria 2,044 psf OK Retained Height = 2.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads 2,044 psf OK Surcharge Over Heel - 0,0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 2,453 psf Axial Load. plied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary Sliding Calcs (Vertical Component NOT Used) Wall Stability Ratios 276.0 lbs Overturning = 1.67 OK Sliding = 1.92 OK Total Bearing Load = `1.,247'lbs ...resultant ecc. = 10.12 in Soil Pressure @ Toe = 2,044 psf OK Soil Pressure @ Heel = 0 psf OK Allowable= 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,453 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 5.9 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 276.0 lbs less 100% Passive Force= - 93.8 lbs less 100% Friction Force = - 436.3 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Load Factors = 150.0 psf/ft Building Code CBC 2013,ACI Dead Load 1.400 Live Load 1.700 Earth, H 2.200 Wind, W 1.300 Seismic, E 1.000 Soil Data Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.350 Soil height to ignore has been Increased for passive pressure = 12.00 In Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom' = 0.00 ft The above lateral load Wall to Ftg CL Dist - has been Increased 1.00 by a factor of Base Above/Below Soil = Wind on Exposed Stem = 16.0 psf a� Adjacent Footing. Load Adjacent.Fboting Load = 0.0;tbs Footing 1Nidth 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist - 0.00 ft Footing Type Line Load Base Above/Below Soil = 0.0 ft at Back of Wall Wall Material Above "Ht" Poisson's Ratio = 0.300 Stem Construction Top Stem 2nd - Stem OK Stem OK Design Height Above Ftg ft= 2.00 0.00 Wall Material Above "Ht" = Masonry Masonry Thickness = 6.00 8.00 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 32.00 Rebar Placed at - Center . Edge Design Data fb/FB + fa/Fa = 0.575 0.545 Total Force @ Section lbs = 96.0 176.0 Moment.... Actual ft-# = 288.0 533.3 Moment..... Allowable ft-# = 501.0 979.3 Shear..... Actual psi = 2.9 2.8 Shear..... Allowable psi = 45.7 45.4 Wall Weight psf = 47.0 84.0 Rebar Depth 'd' in= 2.75 5.25 LAP SPLICE IF ABOVE in = 24.00 24.00 LAP SPLICE IF BELOW in = 24.00 HOOK EMBED INTO FTG In = 6.00 Hook embedment reduced by stress ratio Masonry Data fm psi = 1,500 1,500 Fs psi = 32,000 32,000 Solid Grouting = No Yes Modular Ratio'n' = 21.48 21.48 Short Term Factor = 1.000 1.000 Equiv. Solid Thick. in = 3.90 7.60 `�� Masonry Block Type Masonry Design Method =Normal =ASD; Weight /, t;} ,^ ��„ ,; �;'•.'�:••��\ Concrete Data fc Fy psi = psi- j)�'_�t .• �X`Y -.e.. Use menu Item Settings > Printing & Title Block to set these five lines of Information for your program. Title 2'0" retain'w 6' wall 110 85c wind Page: Job # ...New... Dsgnr: Date: 18 SEP 2014 Description.... This Wall in File:c.lusersltmallisldocumentslretainpro',1.0,project;files 1pga west tr 36537.signature RetalnPro 10 (c)`1987 2014; Build •Y0:14 613 Icent'a Kw 08@QR5tg4pt Cantilevered Retaining Walf Design %ode: CBC 2013,ACI 318-11,ACI 530-11 I dre $e To ..ORCO BLOCK COMPANY; INC. Footing Dimensions & Strengths FootingiDesign Results _OVERTURNING,:.:.: Toe Width, = 0.00 ft Toe Heel Heel Width = 2.50 .. Factored Pressure = 2,453 0 psf Total Footing Width = 2.50 Mu': Upward = 0 125 ft-# Footing Thickness = 12.00 in Mu': Downward = 0 1,064 ft-# Sloped Soil Over Heel = Mu: Design = 0 939 ft-# Key Width = 0.00 in 1 -Way Shear 0.00 5.86 psi Key Depth = 0.00 InActual 'Allow 1 -Way Shear 0.00 75.00 psi Key Distance from Toe = 2.75 ft Toe Reinforcing = None Spec'd Load @ Stem Above Soil = 96.0 6.00 576.0 fe = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % - = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top .2.00 @ Btm = 3.00 in 450.0 0.28 .126.5 a Earth @ Stem Transitions= Toe: Not req'd, Mu < S' Fr Footing Weighl = Heel: Not req'd, Mu < S ' Fr 468.8 Resisting/Overturning Ratio = 1.67 Key Weight = Key: No key defined Summa, of Overturning &;Resisti.nq Forces & Moments �. _OVERTURNING,:.:.: - .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 180.0 1.00 180.0 Soil Over Heel = 421.7 1.58 667.6 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = Load @ Stem Above Soil = 96.0 6.00 576.0 • Axial Live Load on Stem = = Soil Over Toe = Surcharge Over Toe = Total 276.0 O.T.M. 756.0 Stem Weight(s) = 450.0 0.28 .126.5 Earth @ Stem Transitions= Footing Weighl = 375.0 1.25 468.8 Resisting/Overturning Ratio = 1.67 Key Weight = 2.75 Vertical Loads used for Soil Pressure = 1,246.7 lbs Vert. Component = Total = 1,246.7 lbs R.M.= 1,262.9 • Axial live load NOT Included in total displayed or used for overturning resistance, but is Included for soil pressure calculation. cj 0 tx 11A i ii\-, Im ' Use menu item Settings > Printing & Title Block Title 2'8'• retain w 6' wall 110 85c wind Page: to set these five lines of Information Job # ,..New... Dsgnr: Date: 18 SEP 2014 for your program. Description.... This Wall in File: c:\users\tmallis\documents\retainpro 10 project files\pga west tr 36537 signature RetalnPro 10 (c)1987.2014, Build 10.14.8.13 License : Kw-06o52401BLOCK COMPANY, INC. Cantilevered Retaining Wall Design ;ode: CBC 2013,AC1 318-11,AC1 530-11 License 0: ORCO Criteria Soil Data Surcharge Over Heel = 0.0 psf Retained Height = 2.67 ft Allow Soil Bearing = 2,500.0 psf Surcharge Over Toe = 0.0 psf Wall height above soil = 6.00 ft Equivalent Fluid Pressure Method. Heel Active Pressure - 40.0 psf/ft 2,326 psf .rAxial. Load Applied to Stem Slope Behind Wall = 0,00 : 1 - 0.0 lbs Axial Live Load = Height of Soil over Toe = 6.00 in Passive Pressure = 150.0 psf/ft Axial Load Eccentricity = 0.0 In Water height over heel = 0.0 ft Soll Density, Heel = 115.00 pcf Sliding Calcs (Vertical Component NOT Used) .Wall Stability Ratios Surcharge Loads - T - Surcharge Over Heel = 0.0 psf Osed To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 2,326 psf .rAxial. Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 In Design Summary Sliding Calcs (Vertical Component NOT Used) .Wall Stability Ratios 365.4 lbs Overturning = 1.86 OK Sliding = 1.75 OK Total Bearing Load = 1,558 lbs ...resultant ecc. 10.07 in Soil Pressure @ Toe = 1,938 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = . 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,326 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel _ 6.1 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 365.4 lbs less 100% Passive Force .= 93.8 lbs less 100% Friction Force = - 545.5 lbs Added Force Req'd =. 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Soil Density, Toe = 115.00 pcf Footingl[Soll Friction = 0.350 Soil height to Ignore for passive pressure = 12.00 in -Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom - 0.00 ft The above lateral load Wall to Fig CL Dist = has been increased 1.00 by a factor of Base Above/Below Soil _ Wind on Exposed Stem = 16.0 psf Adjacent Footing Load Stem Adjacent Footirig Load = OA Itis Footing Width - 0.00 ft Eccentricity - 0.00 in Wall to Fig CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil _ 0.0 ft at Back of Walt = Poisson's Ratio = 0.300 Stem Construction Top Stem 2nd = 21.48 21.48 Stem OK Stem OK Design Height Above Ftg ft = 2.67 0.00 Wall Material Above "Ht" = Masonry Masonry Thickness = 6.00 8.00 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 32.00 Rebar Placed at = Center Edge Design Data 1.000 Fy psi fb/FB + fa/Fa = 0.575 0.885 Total Force @ Section lbs = 96.0 238.6 Moment.... Actual ft-#= 288.0 671.2 Moment.. -...Allowable ft-#= 501.0 979.3 Shear..... Actual psi = 2.9 3.8 Shear.....Allowable psi = 45.7 45.7 Wall Weight psf = 47.0 84.0 Rebar Depth 'd' in= 2.75 5.25 LAP SPLICE IF ABOVE in = 24.00 24.00 IAP SPLICE IF BELOW In= 24.00 HOOK EMBED INTO FTG in = 6.00 Masonry Data Hook embedment reduced by stress ratio I'm psi= 1,500 1,500 Fs psi = 32,000 32,000. Solid Grouting = No Yes Modular Ration' = 21.48 21.48 Load Factors -- Short Term Factor = 1.000 1.000 Building Code CBC 2013,ACI Equiv. Solid Thick. in= 3.90 7.60 Dead Load Live Load 1.400 1.700 Masonry Block Type = Normal Weight" Earth, H Masonry Design Method = ASD ,'a` F.LIZ Wind, W 2.200 1.300`'V. Concrete Data fCsi:= p �,� �T. r.=, Seismic, E 1.000 Fy psi 2414 4'. r �.. Use menu Item Settings > Printing & Title Block Title 2'8'•• retain w 6' wall 110 85c wind Page: to set these five lines of Information Job # ...New... Dsgnr: Date: 18 SEP 2014 -for your program. Description.... This Wall in File: c:\users\tmallis\documents\retainpro 10.project files\pga west tr 36537 signature RetalriPro 10 (c)1987-2014, Build 10:14.8.13 .::..OVERTURN Force Dlstanc lbs ft Heel Active Pressure = LIcense : �W-O§Q5,9401BLOCK COMPANY, INC. icense Yo: RCCOO Cantilevered Retaining Wall Design :ode: CBC 2013,ACI 318-11,ACl 530-11 Surcharge Over Toe = Adjacent Footing Load = Footing Dimensions 8 Strengths_ Footing Design Results Toe Width = p;0.t)`ft Toe Heel Heel Width = 2.75. Factored Pressure = 2,326 0 psf Total Footing Width = 2.75 Mu': Upward = 0 328 ft-# Footing Thickness = 12.00 In Mu': Downward = 0 1,620 ft-# Mu: Design = 0 1,292 ft-# Key Width = 0.00 in Key Depth = 0.00 in Actual 1 -Way Shear = 0.00 6.07 psi Key Distance from Toe = 2.75 ft Allow 1 -Way Shear = 0.00 75.00 psi Toe Reinforcing = None Spec'd fc = ' 2,500 psi F = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm. 3.00 in Toe: Not req'd, Mu < S ` Fr Heel: •Not req'd, Mu < S ' Fr ' Key: No key defined Item .::..OVERTURN Force Dlstanc lbs ft Heel Active Pressure = 269.4 1.22 Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 96.0 6.67 ft-# 329.5 640.3 Total 365.4 O.T.M. 969.9 Resisting/Overturning Ratio = 1.86 Vertical Loads used for Soil Pressure = 1,558.5 lbs. r I .....RESISTING...:. Force Distance Moment lbs ft ft-# Soil Over Heel = 639.7 1di 1,092.8 Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = " Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe Stem Weight(s) = 506.3 0.29 145.3 Earth @ Stem Transitions= Footing Weighl = 412.5 1.38 567.2 Key Weight 2.75 Vert. Component _ Total = 1,558.5 lbs R.M.= 1,805.2 • Axial live load NOT included in total displayed or used for overturning r resistance, but is Included for soil pressure calculation. Use menu item Settings > Printing & Title Block to set these five linea of information for your program. Title 3'47 retain w 6' wall 110 85c wind Page: Job # ...New... Dsgnr: Date: 18 SEP 2014 Description.... This Wall in File: c:\users\tmallis\documents\retain pro 10 project files\pga west tr 36537 signature RetalnPro 10 (c):1987 2014, Build ;t0.14.8.13 ucerise : KKw o66055gg4 1 ..• Cantilevered Retaining Wall Design %ode: CBC 2013,AC1 318-11,AC1530-11 License To ORDS BLOCK COMPANY; INC. Criteria J(Soil Data - - c ,9 Footing Load Retained Height = 3.33 ftAllow Soil Bearing = 2,500.0 psf' Surcharge QWer Heel = 0.0 psf Wall height above soil = 6.00 ft Equivalent Fluid Pressure Method Heel Active Pressure - 40.0 psf/ft Adf#cent Footing Load. = 0.P lbs Slope Behind Wall - 0.00:1 = ...Height to Top = 0.00 ft 1"', Height of Soil over Toe = 6.00 In Passive Pressure = 150.0 psf/ft 411 .1 0.0 psf Water height over heel = 0.0 ft Soil Density, Heel = 115.00 pcf Eccentricity = 0.00 in Soil Density, Toe = 115.00 pcf less 100% Passive Force = - f' FootingllSoil Friction = 0.350 0.00 ft Axial Load Applied to Stem Soil height to ignore Footing Type Line Load for passive pressure = 12.00 in - Orr . Surcharge Loads. 1,964 psf OK Lateral Load Applied to Stem.Adjacent Footing Load Allowable = Surcharge QWer Heel = 0.0 psf Lateral Load = 0.0 #/ft Adf#cent Footing Load. = 0.P lbs Used To Resist Sliding & Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding &Overturning less 100% Passive Force = - The above lateral load Wall to Ftg CL Dist = 0.00 ft Axial Load Applied to Stem has been Increased 1.00 Footing Type Line Load 317.8 by a factor of Base Above/Below Soil 288.0 Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 16.0 psf at Back of Wall 0.0 ft Axial Live Load = 0.0 lbs Shear..... Actual Poisson's Ratio 0.300 Axial Load Eccentricity = 0.0 in Shear.`.... Allowable psi = 4'5.7 Design' $Ummary Stem Construction Top Stem 2nd . 47.0. 84.0 Rebar Depth 'd' Stem OK Stem OK 2.75 Wall Stability Ratios Design Height Above FIE ft = 3.33 0.00 24.00 Overturning = 1.99 OK Wall Material Above "Ht" = Masonry Masonry 24.00 Sliding 1.61 OK Thickness - 6.00 8.00 Total Bearing Load - 1.,905 lbs ...resultant ecc. 10.24 In Soil Pressure @ Toe = 1,964 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,357 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear'@ Heel = 6.6 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 471.0 lbs less 100% Passive Force = - 93.8 lbs less 100% Friction Force = - 666.8 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Load Factors Building Code Dead Load Live Load. Earth, H Wind, W Seismic, E q CBC 2013,ACI 1.400 1.700 2.200 1.300 1.000 Rebar Size = # 4 # 4 Rebar Spacing - 32.00 32.00 Rebar Placed at = Center Edge Design Data fb/FB + fa/Fa = 0.575 0.872 Total Force @ Section lbs = 96.0 317.8 Moment.... Actual ft-# = 288.0 853.9 . Moment..... Allowable ft-# = 501.0 979.3 Shear..... Actual psi = 2.9 5.0 Shear.`.... Allowable psi = 4'5.7 46.0 Wall Weight psf= 47.0. 84.0 Rebar Depth 'd' in= 2.75 5.25 LAP SPLICE IF ABOVE In= 24.00 36.00 LAP SPLICE IF BELOW in = 24.00 HOOK EMBED INTO FTG In = 7.32 Hook embedment reduced by stress ratio Masonry Data I'm psi= 1,500 1,500 Fs psi= 32,000 32,000 Solid Grouting _. No Yes Modular Ratio 'n' = 21.48 21.48 -, Short Term Factor = 1.000 1.000 Equiv. Solid Thick. In= 3.90 7.60 , f} Mason Block Type = Normal Weight y Masonry Design Method = ASD ! •- Concrete Data fc psi C,.r Gni Fl Fy psi:= r �01� A Use menu Item Settings > Printing & Title Block Title 3'4'• retain w 6' wall 110 85c wind Page: to set these five Ifnes of info6atfon Job #. ...New... Dsgnr: Date: 18 SEP 2014 for your program. Description.... This Wall in File: c:\users\tmailis\documents\retainpro 10 project:fites\pga west tr 36537 0g pfurd. Retal0Pto 10 (8)1981 2014; Bulid 1914 8.13 Icense �ti 0594pq1 Cantilevered Retaining Wall Design :ode: CBC 2013,ACI 318-11,ACI 530-11 �Icense To ::8 , . '.BLOCK COMPANY, INC. doting Dimensions & Strengths Footing..Design Results Toe Width _ • 000'ff Toe Heel Heel Width - 3.00 Factored Pressure2,357 0 psf Total Footing Width - 3:00 Mu': Upward = 0 605 ft-# Footing Thickness = 12.00 in Mu': Downward = 0 2,332 ft-# Mu: Design = 0 1,727 ft-# Key Width = 0.00 in Key Depth = 0.00 in Actual 1 -Way Shear = 0.00 6.63 psi Key Distance from Toe =. 2.75 ft Allow 1 -Way Shear = 0.00 75.00 psi Toe Reinforcing = None Spec'd fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd, Mu < S ` Fr Heel: Not req'd, Mu < S ` Fr Key: No key defined Summary of Overturniri , & Resi.§tlng Forces & Moments. OVE,RTURNING..... ....'RESISTING...... Force Ofstance Moment Force b.Istance Moment Item lbs ft ft_# `Ibs ft ft-# Heel Active Pressure = 375.0 1.44 541.2 Soil Over Heel = 893.6 1.83 1,638.2 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = ' Added Lateral Load = Axial Dead Load on Stem = Load @ Stem Above Soil = • 96.0 7.33 703.7 ` Axial Live Load on Stem = = Soil Over Toe = Surcharge Over Toe = Total .471.0 O.T.M: 1,244.9 Stem Weight(s) = 561.7 0.29 163.7 Earth @ Stem Transitions= Footing Weight = 450.0 1.50 675.0 Resisting/Overturning Ratio = 1.99 Key Weight = 2.75 Vertical Loads used for Soil Pressure = 1,905.3 lbs Vert. Component = Total 1,905.3 lbs R.M.= 2,476.9 Axial live load NOT Included in total displayed or used for overtuming resistance, but is Included for soil pressure calculation. Use menu item Settings > Printing & Title Block to set these five lines of information for your program. This Wall In File: c:\users\tmallis\documents\retainpro 10 ense i K1N=06Q594p1: ' BLOC :ens e :To`;.OKRCO K COMPANY Criteria Retained Height = 4.00 ft Wall height above soil = 6.00 ft Slope Behind Wall - 0.00: 1 Height of Soil over Toe ,= 6.00 In Water height over heel = 0.0 ft Surcharge Loads' 1,993 psf OK Sureh'arge O2er Heal = 0.0 psf Used To,.Reslst Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 2,391 psf [Axial Load Applied to Stem: Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 In , -Design Summary Sliding Calcs (Vertical Component NOT Used) Wall Stability Ratios 596.0 lbs Overturning = 2.15 OK Sliding = 1.67 OK Total Bearing Load = 2,344 lbs ...resultant ecc. = 10.09 In Title 4'0" retain w 6' wall 110 85c wind Job # ...New... Dsgnr: Description.... west tr 36537 signature Cantilevered Retaining Wall Design Soil Pressure @ Toe = 1,993 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,391 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 6.7 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 596.0 lbs less 100% Passive Force= - 177.1 lbs less 100% Friction Force = - 820.3 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5: 1 Stability = 0.0 lbs OK Load Factors Soil Data Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf -Soil Density, Toe = 115.00 pcf FootingilSoll Friction = 0.350 Soil height to ignore has been Increased for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft The above lateral load Wall to Ftg CL Dist = has been Increased 1.00 by a factor of Base Above/Below Soil = Wind on Exposed Stem = 16.0 psf Page: Date: 18 SEP 2014 ;ode: CBC 2013,ACI 318-11 ,ACI 530-11 Adjatont Footing Load Top Stem Adjacent' Footing; Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil = 0.0 ft at Back of Wall Thickness Poisson's Ratio = 0.300 Stem Construction Top Stem 2nd - Live Load Stem OK Stem OK Design Height Above Ftg ft= 4.00 0.00 Wall Material Above "Ht" = Masonry Masonry Thickness = 6.00 8.00 Rebar Size - # 4 # 4 Rebar Spacing32.00 16.00 Rebar Placed at = Center Edge Design Data fb/FB + fa/Fa = 0.575 0.575 Total Force @ Section lbs = 96.0 416.0 Moment.... Actual ft-#= 288.0 1,098.7 Moment..... Allowable ft-#= 501.0 1,909.1 Shear..... Actual psi = 2.9 6.6 Shear..... Allowable psi = 45.7 46.2 Wall Weight psf = 47.0 84.0 Rebar Depth 'd' In= 2.75 5.25 LAP SPLICE IF ABOVE in= 24.00 24.00 LAP SPLICE IF BELOW In= 24.00 HOOK EMBED INTO FTG in = 6.00 Hook embedment reduced by stress ratio Masonry Data - fm psi= , 1,500 1,500 Fs. psi = 32,000 32,000 Solid Grouting No Yes Building Code CBC 2013,ACI Dead Load 1.400 Live Load 1.700. Earth, H 2.200 Wind, W 1.300 Seismic, E 1.000 Modular Ratio 'n' Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy 21.48 21.48 = 1.000 1.000 In= 3.90 7.60 = Normal Weight = ASD-� Psi = A%' ,:`1Y.' �' '�* ., psi j C rr t 6) 1 Use menu Item Settings > Printing•& Title Block Title. 4'0" retain w 6' wall 110 85c wind Page: to set these five IineS of Infbrmation Job # ...New... Dsgnr: Date: 18 SEP 2014 for your program. Description.... This Wall in File: c \users\tmallis\documentsketalnpro .40. project (ileslpga•west tr 36537 signature RotalinPio 10 (c):,198.7 2014, Build•.10.14:8:13 License- KKw o&&QQ��88ao1 Cantilevered Retaining Wall Design :ode: CBC 2013,AC1 318-11,ACI 530-11 License ToyRCO BLOCK COMPANY,: INC. Footing Dimensions &.St.rengths Footing Design Results Toe Width = 0.00 ft Toe Heel Heel Width = _3.25. Factored Pressure = 2,391 0 psf Total Footing Width = 3.25 Mu': Upward = 0 1,077 ft-# Footing Thickness = 12.00 in Mu': Downward = 0 3,229 ft-# Surcharge Over Heel = Surcharge Over Toe = Mu: Design = 0 2,152 ft-# Key Width = 12.00 in Actual 1 -Way Shear 0.00 6.6B psi Key Depth = 4.00 in Allow 1 -Way Shear 0.00 75.00 psi Key Distance from Toe = 2,25 ft Toe Reinforcing = None Spec'd 8.00 fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd 596.0 Min. As % = 0.0018 Other Acceptable Sizes & Spacings 0.30 Cover @ Top 2.00 @ Btm= 3.00 In Toe: Not req'd, Mu < S ' Fr ' = 2.15 Footing Weight = Heel: Not req'd, Mu < S.* Fr = 2,343.8 lbs Key: Not Req'd = Mu<S'Fr 2.75 I Summary of. Overturning,:& Resistinct Forces & Moments _ _ _ __,_ ....OVERTURNING..... Force Distance Moment r Item lbs ft ft-# Heel Active Pressure = 500.0 1.67 833.3 Surcharge over Heel - Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = ' Axial Live Load on Stem = Load @ Stem Above Soil = 96.0 8.00 768.0 r Surcharge Over Toe = Total 596.0 O.T.M.. 1,601.3 618.0 0.30 182.5 Earth @ Stem Transitions= Resisting/Overturning Ratio ' = 2.15 Footing Weight = Vertical Loads used for Soil Pressure = 2,343.8 lbs Force Distance Moment lbs It ft-# Soil Over Heel = 1,188.3 1.96 2,327.2 Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = ' Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 618.0 0.30 182.5 Earth @ Stem Transitions= Footing Weight = 487.5 1.63 792.2 Key Weight = 50.0 2.75 137.5 Vert. Component = Total = 2,343.8 lbs R.M.= 3,439.3 ' Axial live load NOT Included In total displayed or used for resistance, but is included for soil pressure calculation. overturning Use menu item Settings > Printing 8 Title Block Title 4'8" retain w 6' wall 110 85c wind Page: to set these five lines of Information Job # ...New... Dsgnr: Date: 18 SEP 2014 for your program. Description.... This Wall in File: c:\users\tmallisldocum:ents\retainpro 10 project files\pga,west tr 36537 signature' RetulnP..ro 10 (c).1,887 301'4; Bulld.10:1.4; 13 (cense KKw MCO' Cantilevered Retaining Wall Design ',ode: CBC 2013,ACI 318-11,AC1 530-11 License To MCO:BLOCK.COMPANY„INC. Criteria Retained Height = 4.67 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00:' Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft r 0.0 lbs Surcharge Loads 2,796 lbs Surcharge- ;Qver Heel = O.O;psf Used.Td,ResistSliding iii Overtuml'ng Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Allowable = Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 In D:ssign Summary 0.0 psi OK WaII Stability Ratios 7.4 psi OK Overturning = 2.21 OK Sliding = 1.63 OK Total Bearing Load = 2,796 lbs ...resultant eco. - 10.41 In Soil Pressure @ Toe = 2,112 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,534 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear .@ Heel = 7.4 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 739.0 lbs less 100% Passive Force = - 225.0 lbs. less 100% Friction Force = - 978.6 lbs Added Force Req'd = ....for 1.5 : 1 Stability = Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E 0.0 lbs OK 0.0 lbs OK CBC 2013,ACI 1.400 1.700 2.200 1.300 1.000 Soil Data Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoll Friction = 0.350 Soil height to ignore has been Increased for passive pressure = 12.00 In Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom ' = 0.00 ft. The above lateral load Wall to Ftg CL Dist - has been Increased 1.00 by a factor of Base Above/Below Soil Wind on Exposed Stem = 16.0 psf Adjacent Footing Load 11 Top AtlJacent"Footing Loatl' _ 0.0.1bs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist - 0.00 ft Footing Type Line Load Base Above/Below Soil 0.0 ft at Back of Wall Masonry Poisson's Ratio = 0.300 Stem Construction 11 Top Stem 2nd fm Stem OK Stem OK Design Height Above Ftg ft = 4.67 0.00 Wall Material Above "Ht" = Masonry Masonry Thickness - 6.00 8.00 Rebar Size _ # 4 # 4 Rebar Spacing - 32.00 16.00 Rebar Placed at = Center Edge Design Data fb/FB + fa/Fa = 0.575 0.741 Total Force @ Section lbs = 96.0 532.2 Moment.... Actual ft-#= 288.0 1,415.3 Moment..... Allowable ft-#= 501.0 1,909.1 Shear..... Actual psi = 2.9 8.4 Shear..... Allowable psi = 45.7 46.5 Wall Weight psf = 47.0 84.0 Rebar Depth 'd' In= 2.75 5.25 LAP SPLICE IF ABOVE In= 24.00 24.00 LAP SPLICE IF BELOW in= 24.00 HOOK EMBED INTO FTG in= 6.23 Modular Ration' Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy = = 21.48 21.48 = 1.000 1.000 in = 3.90 7.60 = Normal Weight =ASD 74 psi =. psi.IN Pk= Hook embedment reduced by stress ratio Masonry Data fm psi= 1,500 1,500 Fs psi = 32,000 32,000 Solid Grouting No Yes Modular Ration' Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy = = 21.48 21.48 = 1.000 1.000 in = 3.90 7.60 = Normal Weight =ASD 74 psi =. psi.IN Pk= Use menu Item Settings'> Printing .& Title Block Title 6'0'•, retain w 6' wall 110 85c wind Page: to set these five 11ne5 of Information Job # ...New... Dsgnr: Date: 18 SEP 2014 for your program. Description.... This Wall In File: c:\users\tmallis\documents\retainoro 10 oroiect files\Daa west tr 36537 sicinature RetalhPro 10 (c) 1987--2014, BuIld70,14.8.13 License Ki4.90i13LOCK C.OM'PANY; INC. Cantilevered Retaining Wall Design :ode: CBC 2013,AC1 318-11,ACI 530-11 LLicenso To , Criteria . Retained Height = 6.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: ' Height of Soil over Toe = 6.00 In Water height over heel = 0.0 ft Surotlarge Loads 2,220 psf OK Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = . 0.0 psf Used for Sliding & Overturning ACI Factored @ Toe = Axial Load Applied. to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0:0 in Design Summary 75.0 psi Wall Stability Ratios NOT Used) Overturning = 2.51 OK Sliding = 1.62 OK Total Bearing Load = 4,042 lbs ...resultant ecc. = 10.93 in Soil Pressure @ Toe = 2,220 psf OK Soil Pressure @ Heel = 0 psf OK Allowable - 2�50Q psf. Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,664 psf ACI Factored @ Heel 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = ' 11.1 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 1,076.0 lbs less 100% Passive Force= - 333.3 lbs less 100% Friction Force = - 1,414.8 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5: 1 Stability = 0.0 lbs OK Load Factors i Building Code CBC 2013,ACI Dead Load 1.400 Live Load 1.700 Earth, H 2.200 Wind, W 1.300 Seismic, E 1.000 Soil Data i Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.350 Soil height to ignore at Back of Wall for passive pressure = 12.00 In Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft The above lateral load Eccentricity has been Increased 1.00 by a factor of Footing Type Wind on Exposed Stem = 16.0 psf Stem Construction •Top Adjacent Footing Load 2nd Adjacent Footing;Loa = A:U lbs Footing Width 0.00 ft Eccentricity 0.00 In Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil = 0.0 ft at Back of Wall Masonry Polsson's Ratio = 0.300 Stem Construction •Top Stem 2nd 3rd . Stem OK Stem OK Stem OK Design Height Above Ftp ft = 6.00 2.00 0.00 - Wall Material Above "Ht" _ Masonry Masonry Masonry Thickness - 6.00 8.00 12.00 Rebar Size = # 4 # 4 # 4 Rebar Spacing = 32.00 16.00 16.00 Rebar Placed at = Center Edge Edge Design Data fb/FB + fa/Fa = 0.575 0.575 0.690 Total Force @ Section lbs = 96.0 416.0 816.0 Moment.... Actual ft-#= 288.0 .1,098.7 2,304.0 Moment..... Allowable ft-#= 501.0 1,909.1 3,340.5 Shear..... Actual psi = 2.9 6.6 7.6 Shear..... Allowable psi = 45.7 46.2 46.2 Wall Weight psf = 47.0 84.0 133.0 Rebar Depth 'd' In= 2.75 5.25 9.00 LAP SPLICE IF ABOVE in = 24.00 24.00 24.00 LAP SPLICE IF BELOW in = 24.00 24.00 HOOK EMBED INTO FTG in = 6.00 Hook embedment reduced by stress ratio Masonry Data I'm psi= 1,500 1,500 1,500 Fs psi= 32,000 32,000 32,000 Solid Grouting = No Yes Yes Modular Ratlo'n' Short Term Factor Equlv. Solid Thick. Masonry Block Type Masonry. Design Method Concrete Data fc Fy 21.48 21.48 1.000 1.000 In= 3.90 7.60 = Normal Weight = ASD psl•= psi '= .Use menu item SetQngs > Printing & Title Block Title 6'0" retain w 6' wall 110 85c wind Page: • to set these five lines of'information Job # ...New... Dsgnr: Date:' 18 SEP 2014 Tor your program.. Description,... This Wall in File: c:\users\tmallis\documents\retainpro 10.project;files\pga west tr 36537.signature Reta(nPro 10 (6);1967 2014,::Bulld 10.14-8:13 t(cense; w o6dSt,41 Cantilevered Retaining Wall Design %ode: CBC 2013,AC1 318-11,ACI 530-11 icense.�o4 OR _ •BLOCK COMPANY; INC. Footing Dimensions &Strengths __, Footing: Design. Results Toe Width = 0.00 ft Toe Heel Heel Width = 4.25. Factored Pressure = 2,664 0 psi Total Footing Width = 4.25 Mu': Upward = 0 2,948 ft-# Footing Thickness = 12:00 in Mu': Downward = 0 7,203 ft-# Adjacent Footing Lcad = Mu: Design = 0 4,255 ft-# Key Width = 12.00 in Actual 1 -Way Shear = 0.00 11.14 psi Key Depth = 10.00 in Allow 1 -Way, Shear = 0.00 75.00 psl Key Distance from Toe = 3.25 ft Toe Reinforcing = None Spec'd fc = 2,500 psi ... Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spee'd Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm: 3.00 in Toe: Not req'd, Mu < S' Fr' 0.36 315.5 Heel: #4@.9.26 in, #5@ 14.35 in, #6@ 20.37 In, #7@ 27.78 in, #8@ 36.57 in, #9@ 46 153.3 0.83 Key: #4@ 9.51 in, #5@ 14.60 in, #6@ 20.62 In, #7@ 28.03 in, ..OVERTURNING....: Force Distance Moment Item lbs ft ft-# Heel Active Pressure = 980.0 2.33 2,286.7 Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 96.0 10.00 960.0 r Total 1,076.0 O.T.M.. 3,246.7 ResistinglOverturning Ratio, = 2.51 Vertical Loads used for Soil Pressure = 4,042.3 lbs Force v Distance Moment lbs ft ft-# Soil Over Heel = 2,242.5 2.63 5,886.6 Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Lcad = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 884.0 0.36 315.5 Earth @ Stem Transitions= 153.3 0.83 127.8 Footing Weight = 637.5 2.13 1,354.7 Key Weight = 125.0 3.75 468.8 Vert. Component = Total = 4,042.3 lbs R.M.c 8,153.3 • Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation.