12-0114 (RER): � r ret IF- 4 4 "� P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760).777-701-1. LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 2/07/12 Application Number:12=000.0- OT -1-4'V' Owner: Property Address: 55385 LAUREL VALLEY STEVE BANGERT APN: 77.5-181-087- - - 55385 LAUREL VALLEY 1r Application description: REMODEL - RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 15000 �)I .�r •1 )1 Contractor: Applicant: Architect or Engineer: BRAUCKMANN INC 50855 WASHINGTON STREET, 22 LA QUINTA, CA 92253 -- -_ PIA- (760) 485-9269 lA Lic. No.: 781834 -------------------------------- ----------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed underrovisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business a o es ' , and my License is in full force and effect. License Class: se No.: 781834 C actor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State ' License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will. have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). . Lender's Name: Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is - issued. have and will maintain workers' compensation insurance, as required by Section 3700 otthe Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EX •MPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become �ythl o the workers' compensation provisions of Section 37 0 of the Labor Code, I elrth ernpF 'th-ffios'e provisions. aD te: t: WARNING: FA UUREIOPSEC ERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the , conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for ' whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as,a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation.. - I certify that I have read this application and state A�above anoniscor ct. 1 agree to comply with all city and county ordinances a state laws relating ctiond bauthorize representatives of thi ount to mer up above-mentioned tion pu es. Date: ignature (Applicant or A nt): LQPERMIT Application Number . . . . . 12-00000114 Permit . . . BUILDING PERMIT Additional desc . Permit Fee 162.00 Plan Check Fee 105.30 Issue Date . . . . Valuation . . . . 15000 Expiration Date 8/05/12 Qty Unit Charge Per Extension BASE FEE 45.00 13.00 9.0000 THOU BLDG 2,001-25,000 117.00 -------------=-----------------------------------------------------------=-- Special Notes and Comments REPLACE 10 WINDOWS & 3 SLIDING GLASS DOORS. 2010 CODES. -----------7---------------------=----------------------------------=------- Other Fees . . . . . . . . .. BLDG STDS ADMIN (SB1473) 1.00 ENERGY REVIEW FEE 10.53 STRONG MOTION (SMI) - RES 1.50 Fee summary Charged Paid Credited ------------------------------ Due ----------------= Permit Fee Total ---------- 162.00 .00 .00 162.00 Plan Check Total 105.30 .00 .00 105.30 Other Fee Total 13.03 .00 .00 13.03 Grand Total 280.33 .00 .00 280.33 L-4c-vooff z$ E,/Ibv 6q L L/�9 7Z C9 A- k�10 G?� vilo 0, FY OF LA QUANTA DING & SAFETY DEPT. APPROVED / FOR CONSTRUCTION DATE % Z BY IGh� y' �o PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Bangert Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/6/2012 Project Address 55385 Laurel Valley La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,000 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -411 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type CavityFeatures see Part 2 of 5 Status Wall Wood Framed R-13 433 Existing Slab Unheated Slab -on -Grade None 600 Perim = 100' Existing t FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (lM 321.0 0.290 0.38 none none Bug Screen Existing Right (S) 46.0 0.290 0.38 none none Bug Screen Existing i HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 20171 RunCode: 2012-02-06713:11:17 ID: 2012-12 Pae 1 of 5 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Bangert Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 216/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by EnemySoft User Number. 20171 RunCode: 2012-02-06T13:11:17 10:2012-12 Pa e 2 of 5 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R Project Name 1 Building Type m Single Family ❑ Addition Alone Date Banger` Residence O Multi Family ❑ Existing+ Addition/Alteration 2/6/2012 ANNUAL ENERGY USE SUMMARY kBtu/ft2- r Space Heating Space Cooling Fans Domestic Hot Water Pumps Totals Percent Better Than Standard: CALCULATED RESULTS ARE NOT CURRENT Fenestration Building Front Orientation: Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (lM 240 321 Fuel Available at Site: Natural Gas (N) 160 0 Raised Floor Area: 0 (E) 240 0 Slab on Grade Area: 600 (S) 160 46 Average Ceiling Height: 8.0 Roof 600 0 Fenestration Average U-Factor: 0.29 TOTAL: 367 Average SHGC: 0.38 Fenestration/CFA Ratio: 12.2% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company MLC Home Performance . 2/6/7012 Address 77625 DElaware Place Name Tom Bachus City/State/ZiD Palm Desert, Ca 92211 Phone 760-360-0066 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address Name City/State/Zip . Phone Signed License # Date Ene Pro 5.1 6 Ene Soft User Numbec 20171 RunCode: 2012-02-06713:11:17 ID: 2012-12 + y''' Pa e 3 of 5 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Bangert Residence Building Type m Single Family ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addition/Alteration Date 216/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area I Factor Cavitv Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Wall -81 0.102 R-13 270 90 Existing_4.3.1-A3 Zone 1 Wall 114 0.102 R-13 180 90 Existing 4.3.1-A3 Zone 1 Wall 240 0.102 R-13 90 90 Existing 4.3.1-A3 Zone 1 Wall 160 0.102 R-13 0 90.Existing 4.3.1-A3 Zone 1 Roof 600 Zone Slab 600 0.730 None 0 180 Existin 4.4.7-A1 Zone 1 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 321.0 0.290 NFRC 0.38 NFRC 270 Existing Old Castle Building Envelpoe IG Zone 1 2 Window 46.0 0.290 NFRC 0.38 NFRC 180 Existing Old Castle Building Envelpoe IG Zone 1 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Overhang Len Hat I LExt REA Left Fin Right Fin Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 Ene yPro 5.1 by EnergySoft User Number., 20171 RunCode: 2012-02-06713:11:17 ID: 2012-12 Page 4 of 5 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Bangert Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 216/2012 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area ft Existing Altered Removed Volume Year Built HVAC System Whole House 3,000 24,000 2000 Totals 1 01 3,000 0 01 1 HVAC SYSTEMS System Name Oty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC DISTRIBUTION System Name Heating Coolin Duct Duct Location R -Value Ducts Tested? Status WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 o m v U) a — System Name Pipe Len th Pipe Diameter Insul. Thick. O FHP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number., 20171 RunCode: 2012-02-06713:11:17 ID: 2012-12 Page 5 of 5 ARCHITECTURAL GUIDE SPECIFICATION SECTION 08 8100 GLASS GLAZING Note to Specifiers: The specifications below are offered as desirable inclusions in glass and glazing specifications (section 08 81 00), but are not intended to be complete. An appropriate and qualified Architect or Engineer must verify suitability of a particular product for use in a particular application as well as review final specifications. PRODUCTS Approved Glass Fabricator Oldcastle BuildingEnvelopeTm Glass Description, FLOAT GLASS 1. USA - Annealed float glass shall comply with ASTM C1036, Type I, Class 1 (clear), Class 2 (tinted), Quality -Q3. Canada - Annealed float glass shall comply with CAN/CGSB-12.3-M, Quality -Glazing. 2. USA- Heat -strengthened float glass shall comply with ASTM C1048, Type I, Class 1 (clear), Class 2 (tinted), Quality Q3, Kind HS. Canada - Heat -strengthened float glass shall comply with CAN/CGSB-12.9-M, Type 2 -Heat -Strengthened Glass, Class A -Float Glass. 3. USA - Temperefloat-glass shall comply with ASTM C1048, Type I, Class 1 (clear), Class 2 (tinted), Quality Q3, Kind FT. Canada 1Tempered float glass shall comply with CAN/CGSB-1 2.1 -M, Type 2 -Tempered Glass, Class B -Float Glass. ",4) 11ag4. USA I-Jinated l ss to comply wiASM'C72"Canada-Lamintelass'to comply with CAN/CGSB-12.1-M, Type i-Lamiria` ted GI s, Clss B-Flo�la� ����:.�� 5. Glass shall be annealed,lheat-strengthened or tempered as required,by.codes, or as required to meet thermal stress and wind loads.�.� EX o n g �� �� � Sealed Insulating Glass (IG) GENERAL, U kI _jI � b U v � u � p-) � Vision Glass (vertical) Q) 1. IG units consist of glass lites separated by a dehydrated airspace that is hermetically dual sealed with a primary seal of polyisobutylene (1316), or thermo plastic spacer (TPS) and a secondary seal of silicone or an organic sealant depending on the application. 2. USA - Insulating glass units are certified through the Insulating Glass Certification Council (IGCC) to ASTM E2190. Canada - Insulating Glass units are certified through the Insulating Glass Manufacturers Alliance (IGMA) to either the IGMAC certification program to CAN/CGSB-12.8, or through the IGMA program to ASTM E2190.. IG VISION UNIT PERFORMANCE CHARACTERISTICS 1. Exterior Lite 1/4" PPG Solarban® 60 on Clear Low -E #2 2. Interior Lite 1/4" Clear 3. 1/2" Cavity Air (Standard) 4. Performance Characteristics Winter U-factor/U-Value (Btu/hr-ftz-F°): 0.29 Visible Light Transmittance: 70% Summer U-factor/U-Value (Btu/hr-ftz-F*): 0.27 Visible Light Reflectance (outside): 11% Solar Heat Gain Coefficient: 0.38 Visible Light Reflectance (inside): 12% Shading Coefficient: 0.44 Total Solar Transmittance: 33% Relative Heat Gain: 92 Total Solar Reflectance (outside): 29% Light to Solar Gain: 1.84 Ultraviolet Transmittance: 19% Contact Oldcastle Building EnvelopeTm at 866-Oldcastle (653-2278) for samples or additional information concerning performance, strength, deflection, thermal stress or application guidelines. GlasSelect® calculates center of glass performance data using the Lawrence Berkeley National Laboratory (LBNL) Window 5.2 program (version 5.2.17) with Environmental Conditions set at NFRC 100-2001. Gas Library ID#1 (Air) is used for Insulating Glass units with air. Gas Library ION (10% Air/90% Argon) is used for Insulating Glass units with argon. Monolithic glass data is from the following sources: 1. LBNL International Glazing Database (IGDB) version 17.3; 2. Vendor supplied spectral data files. Laminated glass data is from the following sources: 1. LBNL International Glazing Database (IGDB) version 17.3; 2. LBNL Optics 5 (version 5.1 Maintenance Pack 2); 3. Vendor supplied spectral data files; 4. Vendor supplied data. November 14,-2011 Steven Bangert 10842 Wilkinson Ave. Cupertino, CA 95014 Reference: 55-385 Laurel Valley, La Quinta Architectural Change Request — Patio Slider Door Window Change . Dear.Steven Bangert: The Architectural Committee of PGA WEST II Residential Association met on November 10, 2011 and, among other items, reviewed your Application for Architectural Change for your home at 55- 385 Laurel Valley at PGA WEST II.' The Committee approves of the application contingent upon the following conditions. • A Notice of Completion Form must be submitted to the Association when the project is completed. Review by the Committee is only for general conformance with the Architectural Rules It is the responsibility of the owner to fully understand and conform to the Architectural Rules criteria whether or not all deficiencies are noted during the review. It is also the owner's full responsibility to field very all existing conditions. The Committee's decision with regard to Rroiect design will be final. Please refer to the Architectural Rules for all required submittals. Approvals given by the Architectural Committee are good for only six months from the date of the approval letter. If construction has not commenced within six months after the project approval date, a new application must be submitted. If you have any additional questions or concerns, please do not hesitate to contact Joanne Rose, CLAM, Association Manager, at 760/776-5100, Ext. 320. Sincerely, PGA WEST II RESIDENTIAL ASSOCIATION For Architectural Committee Cc: unit Bin. # :... City of La Qurnta Bufld pg & Safety Dlvirlon . Perinit # P.O. Box 1504, "78-495 Calle Tamplw .1� I.a.Quinta, CA 92233 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Add=: PK * Cee ^- Owner's A. P. N.umber.. Address: Legal Description: Contractor. City, ST, Zip: Telephone: ? Address:,Sf Ss to g .,`SV ZZ7 NectDescription: Lo110 WS tit�� City, ST, Zip: u (C.� CO!— 9211)r3 Telephone: zo gS' ��'� /11 State Lic. # : g 1$ City Lie. k. 10 .lj) Arch4 Engr., Designer. Address: City., ST, Zip: L.• Telephone: Construction Type:. Occupancy: State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: �t Sq. Ft.; # Stories: # Univ: JA Telephone # of Contact Person: 9,(-,0 Estimated Valueof Project:/,5 C?V9 APPLICANT: DO NOT WRITE BELOW THIS UNE 0. Submittal Plan Sets Req'd Recd TRACEING PERMITFEES Plan Check submitted Item Amount Structural Calls. Reviewed, ready for corrections Plan Check Deposit. . Truss Calcs. Called Contact Person Plan Check Balance _ Mile 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted.. Mecharilcal G'ading plan V Review, ready for correctionsfissue Electrical Subeontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. ILO.A. Approval Plans resubmitted Grading IN HOUSE:- '^' Review; ready for correctionsftue Developer Impact Fee Planning Approval. Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees . Total Permit Fees P,:O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT (760) 777-7012 FAX (760) 777-7011 Finance Department, Please Collect The Following Fees For The Services Rendered HTE APPLICATION No. 12-011 PROJECT: BANGERT RESIDENCE ADDRESS: 55-385 LAUREL VALLEY CUSTOMER: BRAUKMANN, INC. e OCT 0 6 2012 CITY OF LA QUINTA FINANCE DEPT. SERVICES RENDERED: ORIGINALLY SUBMITTED PRESCRIPTIVE ENERGY CALCULATIONS DO NOT COMPLY FOR SCOPE OF WORK - REVISED PERFORMANCE CALCULATIONS SUBMITTED TO SHOW COMPLIANCE WITH WINDOW AND DOORS VALUES EXCEEDING PRESCRIPTIVE REQUIREMENTS — HOURLY PLAN REVIEW. Fees: PLAN REVIEW @ $35.00 PER HOUR PR (1.00 -HR) — 9/12/2012: .................................................$ 35.00 Date: 9/12/2012 Initials: AJ TOTAL FEES'NOW DUE :............:.:.:......:.....$ 35.00 CITY -OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION GATE 9 h ti. 13y3w®/ Permit # 12• bull City of La Quinta Building &r Safety Division �yk�l 1 P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253. (760) 777-7012 Building Permit Application and Tracking Sheet j( Project Address: �5rj/b��� V wner's Name: A. P. Number: _ Address: SS3� psi, Legal Description: Cib', ST, Zip: QUtDvp I A. d Contractor. AA.) 40 .. .�. Address: rjnC[� W A15 til ilCo-rb& ST - Cit)•, ST, Zip: CA PU ( r7. CA, 4 Telephone:7, ;C State Lic. # : 3 Arch., Engr., Designer: Address: City, ST, Zip: Telephone: State Lic. #: Name of Contact Person: Telephone # of Contact Person # Submittal Plan Sets Structural Calcs. Truss Calcs. Title 24 Calcs. Flood plain plan Grading plan Subcontactor List Grant Deed H.O.A. Approval IN HOUSE:- J Planning Approval Pub. Wks. Appr School Fees Z6 CityL�c#: I Descriptiln: 1rJ000x_ 7 q-1—��T J I Total Permit Fees N e:POccu anc •�Pti.circle rConstructionTv one): NewAdd'n Alter Repair Demo eu-V_ /OAI4(4 # Stor' s: # Units: %� -4-� Cl Z eaue of Project: &"Sen APPLICANT: DO NOT WRITE BELOW THIS LINE I'd Ree'd TRACKING Plan Check submitted 7PERMITFEES Item Amount Reviewed, ready for corrections Plan Check Deposit Called Contact Person Plan Check Balance Plans picked up — Construction Plans resubmitted Mechanical 2" Review, ready for corrections/issue Electrical Called Contact Person Plumbing Plans picked up S.111.1. Plans resubmitted Grading '~ Review, ready for corrections/issue Developer Impact Fee Called Contact Person A.I.P. P. Date of permit issue J I Total Permit Fees N Bangert Residence From: Buddy Paoli <buddyp@herirysglass.com> To: lenchdesign <lenchdesign@aol.com> Subject: Bangert Residence Date: Mon, Aug 27, 2012 9:07 am Sorry for the. delay, I've been out of the office working at job sites. We supplied: 2000 Hoppers 2000 Fixed 4500 Sliding Glass Doors --- We only have simulated values for the 2000 series Hoppers w/ Grey SB60 Glass: Sim U -Value: 0.51 Sim SHGC: 0.21 Flxed.w/Grey SB60 Glass: Sim U -Value: 0.37 Sim SHGC: 0.25 Fixed w/ Clear SB60 Glass: Sim U -Value: 0.37 Sim SHGC: 0.34 If simulated values don't work for your use. You can use California Default Values: Hoppers: U -Value: 0.66 SHGC: 0.63 Fixed: U -Value: 0.55 SHGC: 0.69 --- We have tested the doors. Their values are: U -value: 0:46 SHGC 0.31 Buddy Paoli Senior Estimator Glazcon Production, Inc. 79-919 Country Club Drive Bermuda Dunes, Ca 92203 Tel (760) 360-2800 ext 310 Fax (760) 360-3808 HENRYSGLASS.COM GLAZCON.COM Page 1 of 1 The information contained in this message may be privileged, confidential, and protected from disclosure. If the reader of this message is not the intended recipient, or any employee or agent responsible for delivering this message to the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please notify us immediately by replying to the message and deleting it from your computer. http://mail.aol.com/36912-111/aol-6/en-us/mail/PrintMessage.aspx 8/27/2012