06-1224 (RER)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 06-00001224
Property Address: 51310 CALLE JACUMBA
APN: 770-166-004-21 -000000-
Application description: REMODEL - RESIDENTIAL
Property Zoning: MEDIUM DENSITY RES
Application valuation: 25000
Applicant:
Architect or Engineer:
------------------
LICENSED CONTRACTOR'S DECLARATION
4 �w4�rw
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
KELLY LUELLEN
kLLE JACUMBA
CA, CA 92253
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: A D06 D12 License No.: 778157
Cate: 0-W✓71 w Contractor:
[---— ` OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred•dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.). '
(_ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a coritractor(s) licensed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , 8.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT .
?T INC
CROW ROUTE
:UCAMONGA,
(909)980-6222
Lic. No.: 778157
CA 91730
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/24/06
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are: -
-Carrier STATE FUND Policy Number 0014547
I certify that, in the per of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
j 3/7.00 of the Labor C!%,We(,I. shall forthwith comply with those provisions.
Dater/ 10fo Applicant;- 7Y" -
- r �
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($1100,OdO). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that 1 have read this application and state that the above information is correct. 1 agree to comply with all
city and county ordinances and state laws relating to building construction, arid hereby authorize r esentati s
of this county t enter upon the above-mentioned property inspe ion purpos
.r
�Date:�=1z `�1 ^' Si gnature )Applicant oM1 Agent):
D� "i_ s
Application Number 06-00001224.
Permit . . . BUILDING PERMIT
Additional desc .
Permit Fee. . . . . 252.00
Plan Check
Fee
163.80
Issue Date . . . .
Valuation
. . .
. 25000
Expiration Date 10/21/06
Qty Unit Charge. Per
Extension
BASE FEE
45.00
23.00 9.0000 THOU BLDG 2,001-25,000
207.00
-----------------------------------------------
Special Notes and Comments
-----------------------------
RE -LEVELLING FLOOR SLAB WITH RETROFIT
PIERS AND CHEMICAL GROUT.April 21, 2006
1:54:44 PM jjohnson
----------------------------------------------------------------------------
Other Fees . . . . . . . . ENERGY
REVIEW FEE
16.38
• STRONG
MOTION (SMI)•-
RES
2.50
Fee summary Charged Paid
Credited
Due
-------------------------------------
Permit Fee Total 252.00
----------
.00
----------
.00
252.00
Plan Check Total 163.80
.00
.00.
163.80
Other Fee Total 18.88
.00
.00
18.88
Grand Total 434.68
.00
.00 f
434.68
LQPERMIT
License Detail
Page I of 2
California Home Friday. A
�- ,�
\1/olcome-to Ca i ornZa
7�1
b'
I
License Detail CALIFORNIA CONTRACTORS STATE LICEN
Contractor License # 778157
DISCLAIMER
A license status check provides information taken from the CSLB license data base. BeforE
on this information, you should be aware of the following limitations-
. CSLB complaint disclosure is restricted by law (B&P 7124.6). If this entity is subject tc
complaint disclosure,'a link for complaint disclosure will appear below. Click on the lin
button to obtain complaint and/or legal action information.
. Per B&P 7071.17, only construction related civil judgments reported to the CSLB are
disclosed.
. Arbitrations are not listed unless the contractor fails to comply with the terms of the
arbitration.
. Due to workload, there may be relevant information that has not yet been entered ont
Board's license data base.
Extract Date- 04/21/2006
* * * Business Information * * *
EAGLELIFT INC
11017 ARROW ROUTE
RANCHO CUCAMONGA, CA 91730
Business Phone Number- (909) 980-6222
Entity: Corporation
Issue Date- 05/02/2000 Expire Date: 05/31/2006
* * * License Status * * *
This license is current and active. All information below should be reviewed.
* * * Classifications * * *
ClassI Description
0 GENERAL ENGINEERING CONTRACTOR
D06 CONCRETE RELATED SERVICES
D12
SYNTHETIC PRODUCTS
* * * Bonding Information * * *
littp://www2.csIb.ca.gov/CSLB_LIBRARY/License+Detail.asp 4/21/2006
Bin'# C,
A.
City of La Quinta
Building 8L Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit # '
1
Project Address: $'I L31 0 GALL 15 TA GN 410A
Owner's Name: K.E LL`( LU r� L L t N
A. P. Number:
Address: 5 13 10 CAL F, TA ciA M M
Legal Description:
Contractor:
City, ST, Zip: LA aLA)tJTA ) CA
Telephone: ,.
Y
Address:, I Ib 17 Agow )406'j
Project Description: KE — LIEVE LU N 6 'j H E
City, ST, zip: KAP (" 'b W6A MONG , cA jil3o
r -L o 1Z SLAB OP THE +bUSL:r AND
Telephone: qOq' 980-6222
TIRE CAgAGe.W51NG FE1Ro FST
State Lic. # : -77 4315 7 City Lic. #:
Arch.,"Engr.,Designer: STEV'ew L'. y�L�)Z1Gtl
1�11;:.,� $ AN() c M V -m tC AL ��u7
Address: '300+0 +0 41Z 16T 1 N 6&4AT
City, ST, Zip: QE PLAN DS ,, GA R 2 313
Telephone: ' al V q— 3 �9 7 3 i 6
.s:
Construction Type: Occupancy: 2
State Lic. #: G EDV% 3941
Project type (circle one): New Add'n Alter, epair Demo
Name of Contact Person: SIZAN I) k TAY LOO
Sq. Ft.: I Z
# Stories: �,
# Units: 1
Telephone # of Contact Person: 9dq- 980. 6 2 2 2
Estimated Value of Project: 2K, 00 O
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACKING. PERMIT FEES
Plan Sets
Plan Check submitted Item Amount
Structural Calcs.
Reviewed, ready fo corrections Lf Plan Check Deposit
Truss Calcs.
Called Contact Person Plan Check Balance
Energy Cal cs.
Plans picked up 11&1#b Construction
Flood plain plan
Plans resubmitted Pme,chanical
Grading. plan
2"' Review, ready for•corrections/issue Elec '
Subcontactor List
Called Contact Personlambing N
Grant Deed
Plans picked up S.M.I. lobok Tic) N
H.O.A. Approval
Plans resubmitted Grading �- r
IN HOUSE:-
''" Review, ready for corrections/issue Developer Impact Fee
Planning Approval
Called Contac n
Pub. Wks. Appr
Date of peit issue
School Fees
(• ` �' (� `'9 2(�/
4
T4
T al Permit Fees
Y4 &e -*31104 R 1""IFCA—�
DrY
T6 V_TT__ t
,015 �Z 40,,��
C.
{yj/
PRODUCT AND SERVICE WARRANTY
I. Limited Lifetime Warranty
A. Sole and Exclusive Purpose
11017 Arrow Route
Rancho Cucamonga, CA 91730
(877) 752-2522 Office
(877) 752-2526. Fax
�1
The sole and exclusive purpose of the Limited Lifetime Warranty is to provide free adjustment, repair or replacement of
the EagIeLIFT, Inc. installed piers/structural polyurethane during the Warranty period should any of the materials fail to
perform as intended within the limits and exclusions stated herein.
B. Failure to Perform
A pier or structural polyurethane fails to perform as intended when the foundation in the immediate area of Scope of Work
settles or moves downward after the completion of The Work.
C. Sole and Exclusive Remedy
The sole and exclusive remedy, which EagIeLIFT, Inc. is obligated, is limited to repair, replacement or adjustment of the
pier or reinjection of the structural polyurethane.
D. Warranty Period
The warranty period is the period of time in which the present owner holds title to the property.
II. Warranty Transfer
A new Owner transfer fee of $100 is required to transfer the Limited Lifetime Warranty along with a signed copy of the
Warranty Transfer Document within 60 days of the title transfer of the property.
III. Exclusion of the Warranty
A. Heave: Heave or movement of the foundation due to soil expansion is excluded.
B. Settlement: Settlement of interior floor slab or foundation is excluded except in the immediate area of The Work as
described in I.B. (Failure to Perform).
C. Area of Responsibility: All areas outside the immediate area of The Work are excluded from this Warranty.
D. Consequential Damages: This Warranty does not include the repair which is the result of consequential damages
including damage to concrete, brick, mortar, walls, wallpaper, paint, doors, windows, rigid materials or furnishings.
E. Catastrophic Events: The installation of piers/structural polyurethane is not warranted against damages caused by
slope failure, soil creep, earthquakes, flood, seismic events, explosions or other acts of God. The Owner shall not
hold EagIeLIFT, Inc. responsible for catastrophic direct damages should they occur.
IV. Inclusion
The following are included as part of the Warranty by specific reference:
0 Contract lor The Work
• Limitations for The Work
• Cost of Services
• Limited Lifetime Warranty
Subject to this Limited Warranty, Owner agrees that there are no warranties, express or implied, made by EagIeLIFT, Inc.
concerning the work contemplated by this agreement to the fullest extent permitted by applicable law. EagIeLIFT, Inc.
hereby disclaims and owner hereby waives, all implied warranties relating to the work contemplated by this agreement
including, but not limited to implied warranties of merchantability, habitability, construction in a good and workmanlike
manner, condition, suitability, fitness for a particular purpose, and adequacy of the plans. Any implied warranties which
cannot lawfully be disclaimed, are limited in duration to one (1) year.
V. Final Payment
This Warranty becomes valid only upon receipt of final payment.
I N I T I A L S
LICENSED GENERAL CONTRACTOR
AZ License #ROC179618; CA License #778157; NV License #55910
CITY OF LA QUINTA
PLAN CHECK CORRECTION LIST
Steven C. Helfrich/ Helfrich Asso.
30640 Kristin Court
Redlands, CA 92373
PLAN CHECK NO.
ADDRESS
SCOPE OF WORK
06-1224
51-310 Calle Jacumba
Slab leveling repair
April 20, 2006
SECOND CHECK/ APPROVED
OCCUPANCY R3/U1
TYPE -OF -CONST. V -N
PLAN CHECK FEE: 2 Hours total
The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our
professional opinion the plans are in substantial conformance with the building codes and regulations
adopted by the CITY OF LA•QUINTA and the State of California Amendment.
-------------
APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING
APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND
ASSOCIATIONS.
Plans checked by: Hue C. Luu PE
VCA CODE GROUP
2200 W Orangewood Ave, Ste 155
Orange, CA 92868
(714) 363-4700 ext.#752
VCA File No. LQ -18428
+ JPkick
Associates
Engineering and .
Construction Consulting
March 24, 2006
Don Moody
EagleLIFT, Inc.
11017 Arrow Route
Rancho Cucamonga, CA 91730 ti
Subject: Assessment and Repair Recommendations
Luellen House
51310 Calle Jacumba
La Quinta, California 92253
Project No. 10289
The following report describes results of our recent analyses of available field and laboratory testing at the
above residence in Calle Jacumba. Site observations and field work were conducted on March 17, 2006.
Scope of Services
Our services have been provided to assess and analyze the cause and extent of soil and foundation
movement, and to prepare recommendations for appropriate repairs to the house. The scope of services
performed for this study includes:
Visual observations of the house and surrounding conditions;
Subsurface exploration to a depth of 5 feet;
A floor level survey of the house;
Laboratory testing of samples recovered from the excavation to determine pertinent engineering
properties; and
Engineering analyses and preparation of this report.
30640 Kristin Court, Redlands, CA 92373 — 909-389-7316 — fax 909-389-7326 — www.helf i . s ociat s. orn
f� MAR 2.4 2006
Assessment and Repair Recommendations
Luellen Residence
Page No. 2
Our services were conducted in accordance with the standard of care typically practiced by reputable
professionals in this and similar localities. We make no other warranties, either express or implied.
Floor Level Survey
A floor level survey was performed to determine'the slope of the floor of the house and to identify the
nature and extent of foundation movement. In general, the floor survey shows that the floor slopes down
toward the west side of the house.
The high point on the floor slab is located at the corner of the smaller bedroom and the closet wall in the
mid portion of the house. The low point on the slab is located at the main entrance. The total differential
between these two points, which are about 17 feet apart, is 3.7 inches.
There is also evidence of differential settlement of the garage with respect to the house. Separation of the
living room fireplace from the house can be observed from inside the garage. The garage floor has settled
as well, mainly at the corner adjoining the front entrance of the house.
Field Investigation
The house is a single story, wood frame and stucco structure with a shallow foundation system. The house
has a conventionally framed roof with tile roofmg. The house was built about 40 years ago on a level lot
in a relatively level subdivision. The house does not have rain gutters. Water is carried off the lot via
surface drainage, which is generally poor around the house. Surface water from rain and irrigation water
ponds in the front yard due to lack of proper slope.
Damage to the house consists of mainly of soil settlement under the floor slab at the entrance to the house.
This settlement has led to the formation of a ridge which has its lowest point under the main door. Most
of the visible floor cracking is on the garage slab. Some cracks due to settlement are also visible on the
wall between the living room and the garage.
We excavated a test pit adjacent to the southeast corner of the house, as shown on the attached site plan.
The test pit adjacent to the house was excavated to expose the footing (12 inches deep and 6 inches below
grade), and a hand auger was used to excavate the soil below the footing. We retrieved relatively
undisturbed samples of the in-situ soils within the test pits utilizing a split -tube ring sampler for further testing.
Logs of the excavations are attached in Appendix A.
We excavated to a depth of 5 feet below the existing ground surface. Groundwater was not encountered
in the test pit, and is expected to be below 10 feet. Frost depth is not a design or construction
consideration for this home.
Assessment and Repair Recommendations
_ Luellen Residence
Page No. 3
Soils encountered in the test pit consists of inorganic silts of low plasticity. The samples retrieved had
moisture contents ranging from 4.0 to 15.1 percent. The moisture contents of the samples increase with
depth. Dry densities of the soil ranged from 81.7 to 90.9 pounds per cubic foot. Although no corrosive
tests were performed, corrosive soils are expected. Corrosivity of the soils, however, is not expected to
adversely affect the performance of the proposed pier foundation system.
Engineering Analyses and Evaluation
Piers will be used to stabilize and re -level the home in the areas shown on the attached plans. Piers will
be installed to a depth sufficient to stabilize the foundations. This depth is estimated to be at least six feet,
where the allowable soil bearing pressure is greater than 1000 pounds per square foot. The foundations
will then be lifted to as level as practicable. The piers are not intended to resist seismic or wind lateral loads
from the soil or from the structure. The original lateral load -carrying ability of the foundation system is
restored after the structure is leveled byusing flowable fill, sand -cement slurry, or approved alternative to
restore soil support to the foundations.
Because the soil support is restored after placement of the piers (using the sand -cement slurry or approved
alternative), sustained loads on the piers are limited. Therefore, settlement of the piers under design loads
will be within construction tolerances (less than %2 inch total, and less than 1/240 differential slope). The
connections between the piers and the foundations are, therefore, only used during the lifting process, and
are not designed or intended to transfer significant loads from the structure to the piers.
Structural calculations are presented in Appendix C. These calculations show that for four cases oftypical
structures (one and two story, raised floor and slab -on -grade foundations), the maximum spacing of the
piers ranges from six to 12 feet. This spacing is based on the conservative assumption that the foundations
are built of unreinforced concrete, and also satisfies the load limit of 16,500 pounds. Occasionally larger
spacing will be required to avoid placing undue stress on the structure framing system. These conditions,
if present, are identified on the plans, and require that steel beams are used between piers to allow
additional piers to be installed, as required.
Conclusions
The soil around the house has been subj ect to ponding during the rains and from lawn irrigation. This is the
likely cause ofthe settlement of the floor slab of the house. However, soils immediately underlying the
foundation at our test pit location have a lower density than the deeper soils and settlement of the
foundations may have occurred due to loads on this relatively softer layer.
Assessment and Repair Recommendations
Luellen Residence
Page No. 4
Recommendations
Although the interior portion of the house has lifted relative to the perimeter foundations because of soil
expansion, it is impractical to lower the slab to the level of the foundations. Therefore, we recommend that
the perimeter foundations be lifted to the level of the interior slab. In order to mitigate future foundation
movement and to improve the serviceability of the house, we recommend that the foundations around the
perimeter of the house be underpinned to stabilize and lift the house. Existing surface and roof drainage
conditions should also be improved.
The attached repair drawings present details of the proposed foundation repairs. These repairs address
vertical movement of the house by stabilizing the foundations and re -leveling the foundations and slab to
the greatest extent practicable, Performance of these repairs should be monitored for at least 12 months.
Details of the proposed repairs are presented below:
Re -level and Stabilize Stabilization and leveling ofthe foundations and slab should be performed -
using a combination of the Grip-Tite Foundation Pier System and restoring continuous foundation
and slab support with a flowable fill, sand -cement slurry, or approved alternative. This repair
method is described on the attached drawings, and consists of pushing steel pipes below the
existing foundations, and lifting the foundations to approximately level. Once the house is
satisfactorily lifted, flowable fill will be used to fill the voids below the foundations and slab and to
re-support.the foundations and slab.
Cosmetic Repairs Cosmetic repairs to the home are likely to consist ofrepairs to the interior and
exterior walls, ceilings, and floor surfaces. This work should be done after the re -leveling and
stabilization work is completed.
Exterior Repairs The most critical component of mitigating expansive soil movement is to
control the moisture content of the soils surrounding and under the house. Surface drainage should
be maintained sloping away from the house (at a minimum of 2% grade) to ensure that water does
not pond next to the foundations. Rain gutters should be installed with downspouts that direct
water away from the foundations, preferably directly to a subsurface drainage system. Planters
should be provided with area drains to prevent water ponding. Irrigation systems should be
carefully monitored to ensure that soils near the home are not over -irrigated. Exterior repairs
should be performed after the foundation repairs are made to restore the landscaping, irrigation,
and patios/sidewalks to their preconstruction condition. Additional maintenance recommendations
are presented in Appendix B.
Assessment and Repair Recommendations
Luellen Residence
Page No. 5
Closure
The recommended repairs are intended to stabilize and re -level the foundations in the affected parts of the
house. Due to the nature ofthe subsurface conditions at the property, additional future movement of the
house should be anticipated. Areas of the home that have not been repaired may experience damage in
the future, although the extent of this damage is anticipated to be minor, provided good irrigation and
drainage maintenance practices are followed.
Floor level surveys should be performed at least every six months to evaluate the effectiveness of the initial
repairs for the first 12 months. Annual floor level surveys are recommended after the first year to verify
performance of the repairs. Results from these surveys should be analyzed to determine if additional
leveling and stabilization are warranted.
We appreciate the opportunity to submit this report. Please call if you have any further questions.
Very truly yours,
Steven C. Helfrich,EE.
Consulting Engineer
ig
Encl.: Repair Drawings
Appendix A - Field Exploration & soiltesting results
Appendix B - Maintenance Recommendations
Appendix C - Structural Calculations ,
QV E$SI14
14
NO. GE00'13812 rn
lip
;SIF
D�
u
APPENDIX A - FIELD EXPLORATION
A N O O W A N O
4�
�e
e'aG�a
a�
�o
o�
a'G
co co
Oa'
4
B10 r
�`o O
o�
s
O
°'opo TI
y°a �
m
a� �
^�a
am M
O
b
oovoorn
o 3.0 c
0'-3 0
rc o o n
cs
3^�od
P► Li W r
:20
CD
7
Ay N'
Sao
c
m
c
ElF
x2xr
3 3 3 co
0 ' ' a
v CD
o � '
i ® PwGp�cQUINTA
,DING 9.j
AFETY DEPT.
AP psRo ED
FOR CON
ON
FIGURE NO. A-1 EAGLELIFT-URETEK SW DATEBORENOL15L-OG
11017 ARROW ROUTE DELLEN HOUSE
RANCHO CUCAMONGA
PH: 877-752-2522
A
N
A
0
J
�
V
N i0
V N
'
3
r
00
o�
� N
o
o
•
�
3
J �
Q N
N
a
co
•
o
0
0
y.
N
Project / Client:
Sample No.:
Description:
Location:
SIEVE ANALYSIS ASTM D-1140
EAGLELIFT Inc.
SO -2611 / Hole 1,.Sample 1 @ 24"-36"
SILT
LaQuinta/ George Callier
Sieve Opening
Inches
mm
Sieve
Size
% LIMITS
Passing Comb. SA
4
100
4"
MEL
3
75
3"
2
50
2"
1.5
38
1.5"
1
25
1"
0.75
19.1
3/4"
0.5
.12.7
1/2"
0.375
9.52
3/8"
0.187
4.75
#4
100.0
0.093
2.36
#8
99.8
0.046
1.18
#16
99.8
0.024
0.6
#30
99.6
0.012
0.3
#50
98.6
0.006
0.15
#100
98.5
0.003
0.075
#200
91.9
Job No.:
6-219-2009
Date Tested:
3/15-17/06
Date Sampled:
03/13/06
Tested By:
MEL
AMEC Earth & Environmental Inc.
4201 Santa Ana Street, Suite F
Ontario, California, 91761
Tel. 1+ (909) 605-6500
Fax 1+(909) 605-6502
www.amec.com
DATEBY
-A
:,T.
Gradation 3-14-06 SO -2611
II111®■®®II111�■M�i���'.�■■■111111■■■II111�■■■
..
..
-
VIII®■■■IIIII�■■■IIIII�`i�lllll�■■■IIIII�■■■
VIII®■■■IIIII�■■■IIIII�■■®\IIIII�■■■IIIII�■■■
.
.
VIII®■■■IIIII�■■®IIIII�■■®111111■■■IIIII�■■■
.. IIIII�■■■VIII®■■®IIIIIt■■®illll�■■■IIIII�■■■
. IIIII�■■■IIIII�■■®IIIIi�■■®11111■■■IIIII�■■■
. IIIII�■■■IIIII�■■®IIIII�■■®IIIII�■■■IIIII�■■■
. 111111■®■IIIIIt■®®IIIII�■■■II�11�■■■111111■■■
PI
IUD
SAND
EQUIVALENT
LL
ASTM
PL
ASTM
ASTM
Opt. Water•
'•
CTIVI
.4.09
460
460
.-
,•
AMEC Earth & Environmental Inc.
4201 Santa Ana Street, Suite F
Ontario, California, 91761
Tel. 1+ (909) 605-6500
Fax 1+(909) 605-6502
www.amec.com
DATEBY
-A
:,T.
Gradation 3-14-06 SO -2611
SIEVE ANALYSIS ASTM D-1140 C-136
Project / Client: EAGLELIFT Inc.
Sample No.: SO -2611B / Hole 1, Sample 2 @ 48"-60"
Description:
Location: LaQuinta/ George Callier
Sieve Opening
Inches
mm
Sieve % LIMITS
Size Passing Comb. SA
4
100
4"
3
75
3"
2
50
2"
1.5
38
1.5"
1
25
1"
0.75
19.1
3/4"
0.5
12.7
1/2"
0.375
9.52
3/8"
0.187
4.75
#4
0.093
.2.36
#8
0.046
1.18
#16
0.024
0.6
#30
0.012
0.3
#50
0.006
0.15
#100
0.003
0.075 1
#200
Job No.: 6-219-2009
Date Tested: 3/15-17/06
Date Sampled: 03/13/06
Tested By: MEL
AMEC Earth & Environmental Inc.
4201 Santa Ana Street, Suite F
Ontario, California, 91761
Tel. 1+ (909) 605-6500 ,
Fax 1+(909) 605-6502
www.amec.com
n LITE.
Gradation 3-14-06 SO -26118
UNION
lllilmmmmllllll■m®Illllli■®IIIIIl■m
1111110
,
111111■��
.. IIIII��®11111®®11111����11111����111111■��
. 111111M®M111111M®®111111MEM111111■EM111111■■M
11111®�®X11111®�®�IIIII����IINII�■��IIIII����
11111®�®X11111®�®®IIIII��■�11111����11111����
SANIIIII®�®�IIIIt®�®�IIIII��■®11111■��IIIII����
•
L
PL
P1
'
C
EQUIVALENTASTM
.
u
CTIVI 217
619
619
619
�- • •Co
...
Y .
•
AMEC Earth & Environmental Inc.
4201 Santa Ana Street, Suite F
Ontario, California, 91761
Tel. 1+ (909) 605-6500 ,
Fax 1+(909) 605-6502
www.amec.com
n LITE.
Gradation 3-14-06 SO -26118
APPENDIX B - MAINTENANCE RECOMMENDATIONS
The most important aspect ofpropertymaintenance is proper control of surface drainage. Uncontrolled
Water from broken pipes, improperly maintained irrigation systems, and rainfall are the most prevalent
causes of soil movement in Southern California. The following recommended procedures should be
followed by the property owner to minimize this movement:
Homes should be provided with roof drains, gutters, and downspouts, and these facilities should
be checked at least twice per year.
ti
2. All drainage devices should be checked at least twice per year to ensure that they are not blocked.
All blockages should he cleared.
3. Water should not be permitted to collect or pond in yard areas. This water will seep into the
ground, loosening the soils, and can cause expansive soil movement.
4. Yards and planters should not be over -irrigated
5. Water should not be allowed to collect against foundations, retaining walls, or basement walls.
These walls are typically built to withstand the effects ofnormal soil moisture, and may require
subsurface drains to collect and transfer excessive water away from the structures.
6. Swales that have been graded around the home or on the lot should not be blocked. These swales
are typically constructed to provide drainage toward the driveways, street or other positive outlet.