Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13626 (SFD)
+4 I r r� L • �11C��� _ P.O. BOX 1504 N o . 13626 Building 51-365 Calle Jacumba 78-105 CALLE ESTADO Address LA QUINTA, CALIFORNIA 92253 , Owner Joe W. Stemmer VN P.3 SIGNATURE F — DATE I; herebaffirm that I am exem t from the Contractor's License law for the fo Y� OWNED -BUILD D6`G R ION; llowin g reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a perm!%to cofllstruct, alter, improve, demolish, or repair any structure, prior to its issuance also requiress��thefapplicant for such permft to life a signed statement that he is licensed pursuant to the provlo'ns o/ the Contractor's License Law, Chapter 9 (commencfng with Section 7000) o/ Division 3 0/ the Business and Professions Code, or that. he is exempt therefrom, and the basis • for the alleged exemption. Any violation o/ Section 7037.5 Dy 'any applicant Ior a permit subjects the applicant to a civil penalty o/not more than live hundred tl0I O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Coder The Contractor's License Law does not apply to an owner of property who Estimated Valuation , .—'— BUILDING: TYPE CONST. OCC: GRP. Mailing PERMIT" AMOUNT Address _ A.P. Number 763--115 -007 City Zip _ 49. Ott Tel. 1( Legal Description Lot f Desert Club Tract 12 Contractor Plumbing 166.50 Description SFD Sam Grading 20.00 Driveway Enc. " .00 Address - Infrastructure' City State Lic. & Classif. Arch., Engr., Designer Address City Zip Tel. SU5857 Lolly '119 Lic. # Sq. Ft. 1350 No. No. Dw. Size Stories Units New ❑ Add ❑ - Alter ❑ Repair ❑ Demolition ❑ Tel Permit ,,Includes wood fence and 4' block Zip State wall for propane +dank. Lic # CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is /or one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. :— Date Owner NOTICE TO APPLICANT: If. after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I= affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives .of this city to enter the above- mentioned property for inspectibn_purposes. Signature of applicant Date Mailing Addressr City, State, Zip REMARKS -.. ZONE: BY: * ' Minimum Setback Distances: ; Front Setback from Center Line ' Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property/Line FINAL DATE —INSPECTOR, Issued by: Date //lYP rmit'a 1 i Validated by: fi/ Validation: ��y U � %9p_ // LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am license5,underro protisions of Chapter 9 (commencing with Section 7000) of Division 3 of t'e B inesPf,V si.n. Code, and m Hc pse•is in full force and effect A.A J r SIGNATURE F — DATE I; herebaffirm that I am exem t from the Contractor's License law for the fo Y� OWNED -BUILD D6`G R ION; llowin g reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a perm!%to cofllstruct, alter, improve, demolish, or repair any structure, prior to its issuance also requiress��thefapplicant for such permft to life a signed statement that he is licensed pursuant to the provlo'ns o/ the Contractor's License Law, Chapter 9 (commencfng with Section 7000) o/ Division 3 0/ the Business and Professions Code, or that. he is exempt therefrom, and the basis • for the alleged exemption. Any violation o/ Section 7037.5 Dy 'any applicant Ior a permit subjects the applicant to a civil penalty o/not more than live hundred tl0I O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Coder The Contractor's License Law does not apply to an owner of property who Estimated Valuation , .—'— $831155.00 PERMIT" AMOUNT Plan Chk. Dep. ZjQ. QQ Plan Chk. Bal. 7 .� COf1St. - 5�%. ti3 Mech. _ 49. Ott builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. I/, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve /or the purpose o/ sale.) ; ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law' does not apply,to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ I am exempt under Sec. B. & P.C. for this reason Electricaltj Plumbing 166.50 S.M.I.. 4.32 Grading 20.00 Driveway Enc. " .00 Date owner Infrastructure' Precise Plan 2.4.W WORKERS' COMPENSATION DECLARATIONI I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. company 1 ❑ Copy is filed with the city. -0 Certified copy is hereby furnished. TOTAL ,V�1.39 CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is /or one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. :— Date Owner NOTICE TO APPLICANT: If. after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I= affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives .of this city to enter the above- mentioned property for inspectibn_purposes. Signature of applicant Date Mailing Addressr City, State, Zip REMARKS -.. ZONE: BY: * ' Minimum Setback Distances: ; Front Setback from Center Line ' Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property/Line FINAL DATE —INSPECTOR, Issued by: Date //lYP rmit'a 1 i Validated by: fi/ Validation: ��y U � %9p_ // CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES i IST FL. SQ. FT. ® $ UNITS SLAB GRADE Y ra BONDING HEATING (ROUGH) 2ND FL. r SQ. FT. Q FORMS YARD SPKLR SYSTEM POR. SQ. FT. ® MOBILEHOME SVC: BAR SINK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS CARP. SQ. FT. OTHER APPJEQUIP. DRAINAGE PIPING WALL SQ. FT. TEMP. POLE �- ���ddd DRINKING FOUNTAIN. SQ. FT. ® GROUT URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING NOTE: Not to be used as property tax valuation - FLOOR DRAIN MECHANICAL FEES LUMBER GR. WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED � LAUNDRYTRAY AIR HANDLING UNIT CFM FIRE ZONE ROOFING KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SQ. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4 c SEWAGE DISPOSAL SO.FT.GAR ® 3/4c HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK OUND PLUMBING 7—/( ! NDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS PTIC T;A4 K4 uo ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE �- ���ddd GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM FINAL INSP. GRADING FINAL INS '1Jjj�o cu. yd. L $ plus x$ =$ LUMBER GR. FRAMING t/t! -Gj ROOFING ,�� L �����aJA 8� • te l s Y✓K o v✓ 0 ��s 7f,L�-j 30AGf /3 --Ah 9 �07 REMARKS: VENTILATION recls � FIRE ZONE ROOFING FIREPLACE T O rtCTIO SPARK ARRESTOR GAR. FIREWA LATHING MESH INSULATIONISOUNDi?-Z-3-9q49 FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated 619-775-3500 Date 6/24/94 Type of Permit I La Quinta No. 112903 Permit #113626 Owner Name Joe W. Stemmer Log ,No. 77-748 Street Delaware Place City La Quinta Zip' 92253 Study Area 115 APN # 769-115-017 J Tract # 12 Lot # © Square Footage 11350 Type of Development I Single Family Residence No. of units 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.65 X 1350 or $ 2,227.50 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Joe Stemmer Telephone 619 772 3910 Name on the check By Dolores A. Ballesteros '_Z `. Superintendent = 7 ,. Fee collected /exempted by Elizabeth Roper J Signature 2027^ M he, 2027 Collector: Attach a copy of county or city plan check application form to district copy for 11 waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting OCT 26 '94 14:28 PALM DESERT ESCROW t `'P.1 PALUDESERT ESCROW, INC. 7,4-04'1 kohwaw,l I I Post Offlcq,EoX 879 Palm DEsert, California 92261 Fax # (G 19) 568-49S2 Tclephone (6 19) 568-27E37 City of La. Qui nta Date: 10-26-9`4 Via Fax #777-7011 Escrow No.: 947514RW Ellie REQUEST FOR RELEASE OF, LIEN To whom it may concern: An escrow h4i,been opened in this office by: JOE W. STEMMEg SR. -covering property located at: 53 165 Calle Jacumba, La OWLnta, CA —legally described as: Lot 6, Block 3, Desert Club #2 We have been instructed to pay the lien recorded by you on: 3-30-93 as Instrument No. 115554 , Records Of Riverside County, California, in full. Resolution No. 93-21 Please forward your demand, together with a RECORDABLE RELEASE OF LIEN to us as soon as possible. Also being faxed is a copy of my title report showing that all taxes have been paid in full. Thank you for your cooperation in this matter, and should you have any questions, Please call the undersigned. Sincerely, Rheba WFSt by Annie Croudy Escrow Officer ,. v`y� a .�Y�f �Ry'�~ 'x i `a � t ..r- � ` •• ��Q'1 r � }{ • x r'������ii� � ' �+r ,x � Y �' t� t,� 4 .�, ,*�bty, rYi�; �.a ASSESSOR'S PARCEL NUMBER COUNTY OF RIVERSIDE HEALTH SERVICES AGENCY 1 DEPARTMENT OF ENVIRONMENTAL HEALTH PERMIT APPLICATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM APPLICANT:'Submit this form with four copies of a SCALED plot plan (1-20 SCALE) drawn to County specifications as indicated on the attached check list. A non-refundable filing fee is required when the application Is submitted. Check must be made payable to the County of Riverside. Approval of this applica- tion shall remain valid for a period not to exceed one year from date of payment. LOG # Age t, Contractor, Contact rson �� (/� Address Owner Address City State Zap Telephone Q ZO Job Property Address �� Ilp� Cary / f'� /��nl L7 Z' H �� v `) U N Lot Size Water Agency/Well �� � PUP, to. Use of erm�Sfteprep., Legal Descrip on c�rk ct�� T��zelling �x tk� C �L� Metc. Signature o Applicant Date 1A i sAwr G CHE K B& IF REQUI E ❑ Ho ding Tank Agreements Completed r ❑ Detailed Contour Plot Plans Required (1 to 5 foot interval) ❑ Certification of Existing S.D. System Required ❑ Grading Handout Provided m ❑ WQCB Clearance Required ❑ Staff Specialist Lot Inspection Required Z 0 (Attach For DOH -SAN -007, Santa Ana Region Only ❑ Lot Inspection U❑ Soils Percolation Report Required • W "�1`n, ❑, Special Feasibility Boring Report Required ❑ Date Lot Inspection Completed: Initials Remarks: V ^ ' �a�, cP Booklet Provided EJtenn Initials Date ❑Final Inspection by Department of Environmental Health is required. }— p i- C/42 / Soils Percolation Boring Report by ` Uc4Proiect # Date Soils Map Page Soil Type Approved By t Date No of Systems Type of System(s) No. Dwelling Units (1) Septic Tank Soil Rate Grease/Sand ❑ Holding Tank O Replacement VNew C3 Addition Bedroom , Fixture Units f./`. t "r 0 Grease Intcp/Unt Trap Existing ��N11 1000 Gal.• �0t7 Gal. Sq. Ft. Bottom Area Total Linear Ft. Sidewall Allowanoe \ Leach Bed sq. ft. of Bottom Area tt. rock/ sq. k. run Ing -ft:" " Install Une(s) ung" ' tt. wide with Inlet Tested Depth rl NA min. iRchas rock below drainlines or U Proposed Bottom' ested Depth— Z Leach Iines/bed special design for slope: (3) Pit Diameter No. Pits Pit Below Inlet (BI) Seepage Pit Maximum Other: Q I Total Depth Allowable Applicable Depthr W .WA Overburden Factor ❑ 5' 6' O TD rn Well Review, Approved: Date: Well Drilling Permit # SIGNATURE , Grading Plan Approved: Date: ( SIGNATURE Sewer Verification Approved: Date: REMARKS: r This application is APPROV�QENIED for the category checked in SECTION B FOR OFFICE USE ONLY <above,. regarding, a des g a subsurface disposal system as Indicated on the aoomMied plot plan, using the requirements set, forth in SECTION C above. A build- /�O' ��) tng permit. is necessary for the installation of the aove-designed system. No construe. Revenue code J j5 Fee $ / tion -is permitted in the `i;i;: t►ea-reserved1100% expansion area..,,; (1) optic Tank must be 100' minimum from any wells. Check # (2) Leach lines must be 100' minimum from any wells, Including expansion area. Date j 1 �� Initial (3) Sewer lines must be 50' minimum from any wells. Z O(4) eepage pits must be 150' minimum from any wells, Including expansion area. H U UJ _ (0 Sign of Health Official / r Date DOM -SAN 122 (Rev 9/93) Distribution: WHITE -01608 File; YELLOW—Applicant; PINK -1310g. Dept.; GOLDENHOL—Plans/Records STRUCTURAL AND CIVIL ENGINEERING DENISE R. POELTLER, INC. 79-301 Country Club Drive • Suite 202 e Bermuda Dunes, California 92201 19. August 1994 Mr. Lonnie Day CITY OF LA QUINTA Department of Building & Safety. 78495 Calle Tampico 0 La Quinta, CA 92253 -RE: "RETRO -FIT ANCHOR BOLTS 51-365 Calle Jucumba Owner: Joe W. Stemmer, Jr. Dear Mr. Day: In a conversation with Mr. 'Joe Stemmer, it seems that the anchor bolts on shear panel."b" were spaced at 24" on center instead of 16" on center as specified on the approved. building drawings. As a remedy, it is permissible to retro -fit 1/2" diameter RAMSET REDHEAD EXPANSION ANCHORS in between the existing anchor bolts. Please call my office if you have any questions. Respectfully submi ted, DENISE R. POELTLER R.C.E. 33446 - - TFB #94-181X w �O QROFESSIp Q No. 33446 F9 EXP. 6-30-98 N9, C I V L P?�� SOF CAL\fo TEL. (619) 772-3966 • FAX (619) 772-3986 TITLE 24 COMPLIANCE REPORTS ENERGY ANALYSIS FOR LaQuinta CA. NOVEMBER 09 1993 69116 Club Road 0 Cathedral City, CA 92234 ®(61 9) 328-5898 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -IR Project Title.......... Stemmer5 Date........ 03/07/94 ProjectAddress........ --------------------- Documentation Author... Barbara Bartlett Company ................ DESERT ENERGY CONSULTING Telephone .............. (619)328-5898 Building Permit # Plan Check / Date Compliance Method...... MICROPAS4 by Enercomp, Inc. I Field Check/ Date Climate Zone........... 15 --------------------- I MICROPAS4 v4.02 File-STEMMERS Wth-CTZ15S92 Program -.FORM CF -1R I f User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS94033A ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 1350 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade (Package D) Component Type ------------- Wall Roof Door S1abEdge S1abEdge S1abEdge orientation ------------------- Window BUILDING SHELL INSULATION Insulation ------------------------- Assembly (E) R -value U -Value Location/Comments R-13 0.060 , Entry.Living, Mstr.Kit.Din. Door Left MstrBed & Bath, Baths.Beds.Liv, Garage R-30 0.031 Attic R-0 0.330 Entry, Garage R-0 0.900 To Outside R-0 0.720 To Outside R-0 0.550 To Garage ------------------- Window Front (E) Window Front (E) Window Front (E) Window Left (S) Door Left (S) Window Right (N), Area (sf ) FENESTRATION ------------ # of Interior U- Pan- Shading/ Value es Description 15.0 0.720 2 20.0 0.870 2 5.0 0.720 2 9.0 0.870 2 80.0 0.770 2 54.0 0.870 2 --------------- Blinds.Lt Blinds.Lt Blinds.Lt Blinds.Lt Blinds.Lt Blinds.Lt THERMAL MASS ------------ Area Thickness Type Exposed (sf) (in) ------------ -------------- ------ --------- Exterior Shading None None None None None None OV'er- hang/ Framing Fins Type Yes Metal Yes Metal Yes Metal Yes Metal Yes Metal Yes Metal Location/Comments S1abOnGrade S1abOnGrade Yes 641 No 709 3.5 Kit.Ent.Baths.Din 3.5 All Carpet CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Stemmer5 Date........ 03/07/94 I MICROPAS4 v4.02 File-STEMMERS Wth-CTZ15S92 Program -FORM CF -1R User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS94033A I ------------------------------------------------------------------------------- HVAC SYSTEMS WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ ---------- Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS ------------------------ .Minimum Duct Duct Thermostat Equipment Type --------------- Efficiency ------------ . Location ------------- R -value ------- Type Furnace 0.800 AFUE Attic R-4.2 ------------ Setback ACSplit 10.00 SEER Attic R-4.2 Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ ---------- Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS ------------------------ CERTIFICATE OF COMPLIANCE:'RESIDENTIAL Page 3 CF -1R Project Title.......... Stemmer5 Date........ 03/07/94 MICROPAS4 v4.02 File-STEMMER5 Wth-CTZ15S92 Program -FORM CF -1R I User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS94033A ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations,'and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Joe W. Stemmer Company. n/a Address. 52220 Ave. Martinez LaQuinta CA Phone... (619)771-0671 License. n/a Signed.. (date) ENFORCEMENT AGENCY Name.-- Title... ame.-- Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Barbara Bartlett Company. DESERT ENERGY CONSULTING Address. 69116 Club Road Cathedral City, CA 92234 Phone... (619)328-5898 211 SIR A 0,01,75 COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... Stemmer5 Date........ 03/07/94 Project Address........ --------------------- Documentation Author... Barbara Bartlett Company ................ DESERT ENERGY CONSULTING Telephone .............. (619)328-5898 Building Permit # Plan Check / Date Compliance Method...... MICROPAS4 by Enercomp, Inc. Field Check/ Date I Climate Zone........... 15 --------------------- MICROPAS4 v4.02 File-STEMMER5 Wth-CTZ15S92 Program -FORM C -2R User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS94033A I ------------------------------------------------------------------------------- ---------------------------------------------------------------- = MICROPAS4 ENERGY USE SUMMARY = Energy Use Standard _ (kBtu/sf-yr) Design = Space Heating.......... 2.40 = Space Cooling.......... 32.37 = Water Heating.......... 15.22 = Total 49.99 Proposed Compliance = Design Margin = 1.44 0.96 = 32.05 0.32 = 15.22 0.00 = 48.71 1.28 = *** Building complies with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area.......... Glazing Percentage......... Average Ceiling Height..... 1350 sf Single Family Detached New Front Facing 90 deg (E) 1 1 ReducedYear Slab On Grade 1 12782 cf 1350 sf 1350 sf 1350 sf 13.6 % of FA 9.5 ft (Package D) COMPUTER METHOD SUMMARY Page 2 - C -2R Project Title.......... Stemmer5 Date........ 03/07/94 MICROPAS4 v4.02 File-STEMMER5 Wth-CTZ15S92 Program -FORM C -2R User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS94033A ------------------------------------------------------------------------------- Zone Type -------------- HOUSE Residence Surface HOUSE 1 Wall 2 Wall 3 Wall 4 Wall 5 Wall 6 Roof 7 Door 8 Door BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area (sf) (cf) Units itioned Type (ft) (sf) ----------------- ------------------------ ------ --------- 1350 12782 1.00 Yes Setback 2.0 n/a OPAQUE SURFACES --------------- Area U- Insul Act Solar Form 3 Location/ (sf) value R-val Azm Tilt Gains Reference Comments ----- ----- ----- --- ---- ----------------- ---------------- 133 0.060 R-13 90 90 Yes W.13.2X4.FM Entry.Living 191 0.060 R-13 180 90 Yes W.13.2X4.FM Mstr.Kit.Din. 242 0.060 R-13 270 90 Yes W.13.2X4.FM MstrBed & Bath 393 0.060 R-13 0 90 Yes W.13.2X4.FM Baths.Beds.Liv 232 0.060 R-13 90 90 No W.13.2X4.FM Garage 1350 0.031 R-30 90 20 Yes None Attic 20. 0.330 R-0 90 90 Yes None Entry 20 0.330 R-0 90 90 No None Garage PERIMETER LOSSES FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description ----------- ----- ------------- ------ ----- --- --- ---- ---- --------------- HOUSE 1 Window 15.0 2 Metal Fixed 0.720 90 90 0.88 0.88 Blinds.Lt 2 Window 20.0 2 Metal Slider 0.870 90 90 0.88 0.78 Blinds.Lt 3 Window 5.0 2 Metal Fixed 0.720 90 90 0.88 0.88 Blinds.Lt 4 Window 9.0 2 Metal Slider 0.870 180 90 0.88 0.78 Blinds.Lt 5 Door. 80.0 2 Metal Slider 0.770 180 90 0.88 0.58 Blinds.Lt Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ HOUSE ------ -------- ------- ----- ---------------------- 9 S1abEdge 50 0.900 R-0 No To Outside 10 S1abEdge 76 0.720 R-0 No To Outside 11 S1abEdge 21 0.550 R-0 No To Garage FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description ----------- ----- ------------- ------ ----- --- --- ---- ---- --------------- HOUSE 1 Window 15.0 2 Metal Fixed 0.720 90 90 0.88 0.88 Blinds.Lt 2 Window 20.0 2 Metal Slider 0.870 90 90 0.88 0.78 Blinds.Lt 3 Window 5.0 2 Metal Fixed 0.720 90 90 0.88 0.88 Blinds.Lt 4 Window 9.0 2 Metal Slider 0.870 180 90 0.88 0.78 Blinds.Lt 5 Door. 80.0 2 Metal Slider 0.770 180 90 0.88 0.58 Blinds.Lt h, 6 Window 54.0 .2 Metal Slider 0.870 0 90 0.88 0.78 Blinds.Lt Im COMPUTER METHOD SUMMARY Page 3 C -2R -------- ----- ----- Project Title.......... Stemmer5 Date........ 03/07/94 MICROPAS4 v4.02 File-STEMMER5 Wth-CTZ15S92 Program -FORM C -2R User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS94033A ------------------------------------------------------------------------------- OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- HOUSE 1.5 2.5 1 Window 15.0 5.0 2 Window 20.0 5.0 3 Window 5.0 5.0 4 Window 9.0 5.5 5 Door 80.0 5.5 6 Window 54.0 3.0 Area Mass Type (sf) HOUSE 1 S1abOnGrade 641 2 S1abOnGrade 709 n/a 1.5 2.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a 1.5 2.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a 1.5 2.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a 2.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a n/a 2.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a n/a 2.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS ------------ Thick Heat Conduct- Surface (in) Cap ivity R -value Location/Comments 3.5 28.0 0.98 R-0.0 Kit.Ent.Baths.Din 3.5 28.0 0.98 R-2.0 All Carpet HVAC SYSTEMS WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ ---------- Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS Minimum Duct Duct Duct System Type ---------------- Efficiency Location R -value Efficiency HOUSE ------------ ------------- ------- ---------- Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 10.00 SEER Attic R-4.2 0.810 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ ---------- Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS CONSTRUCTION ASSEMBLY Page 1 3R Project Title.......... Stemmer5 Date........ 03/07/94 MICROPAS4 v4.02 File-STEMMER5 Wth-CTZ15S92 Program -FORM 3R I User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS94033A ------------------------------------------------------------------------------= - - - - - - - - r - - -- -------- Sketch r--rrr- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Reference Name . W.13.2X4.FM Description .... Wall R-13 16 oc Type ........... Wall R -Value ........ 13 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------- ------------------- ---------------- U-Value: (1 / 19.14 x 0.85) + (1 / 9.60 x 0.15) = 0.060 Btuh/sf-F Total R -Value: 1 / 0.060 = 16.65 sf-F/Btuh Material Cavity Frame Name ------------- Description ---------------------------------------- R -Value R-Value O. FILM.EX Exterior air film: winter value --------- 0.17 --------- 0.17 1. STUCCO.0.88 0.875 in stucco 0.17 0.17 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c.*BATT.R13 R-13 batt insul (cavity = 3.5 in) 13.00 3f. FIR. 2X4 2x4 in fir framing -- 3.46 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 5. FOAM.4.6 Exterior Foam Insulation 4.60 4.60 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 19.14 9.60 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------- ------------------- ---------------- U-Value: (1 / 19.14 x 0.85) + (1 / 9.60 x 0.15) = 0.060 Btuh/sf-F Total R -Value: 1 / 0.060 = 16.65 sf-F/Btuh HVAC SIZING Page 1 HVAC Project Title.......... Stemmer5 Date........ 03/07/94 Project Address........ _____________________ Documentation Author... Barbara Bartlett Company ................ DESERT ENERGY CONSULTING Telephone .............. (619)328-5898 Building Permit # Plan Check / Date Compliance Method...... MICROPAS4 by Enercomp, Inc. Field Check/ Date I Climate Zone........... 15 MICROPAS4 v4.02 File-STEMMER5 Wth-CTZ15S92 Program -HVAC SIZING I I User#-MP1442 User -DESERT ENERGY CONSULTING Run-JS94033A -------------------------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 1350 sf Volume.. ... ............ 12782 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location.....,....... INDIO Latitude ..... .... ........ 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range ............... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Note: The loads shown are only one of the Criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Cooling Description --------------------------------- (Btuh) ----------- (Btuh) Opaque Conduction and Solar...... 9751 ----------- 4803 Glazing Conduction ............... 6077 5039 Glazing Solar .................... n/a 5040 Infiltration ..................... 7537 4467 Internal Gain .................... n/a 2100 Ducts ............................ 2336 2145 Sensible Load. .................... 25701 23594 Latent Load.... ................ n/a 4719 Minimum Total Load 25701 - 28313 Note: The loads shown are only one of the Criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential'buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether.they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Building Envelope Measures * §150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. * §150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). * §150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. §150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 permAnch. §118: Insulation specified or installed meets California Energy Commission quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltation Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(0: Special infiltration barrier installed to comply with §151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110 -13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(i): Setback thermostat on all applicable heating systems. §1500): Pipe and Tank Insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55°F insulated. 5. Piping insulated between heating source and indirect hot water tank. * §150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers.. §114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously buring pilot light. (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.) Lighting Measures §150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. Revised January 1992 DESIGNER I ENFORCEMENT