Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
0310-336 (SFD)
LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of -the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp�ate 1634981 13 % / p1�31l2C { r% Date 7_ - ,-' Signature of Contractor, OWNER -BUILDER DECLARATION. I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do -the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ! � s /i ( ) 1, as1owner, rt of theoperfy, am exclusively contracting with licensed contractors,J�r oonstruci tjbig project (Sec. 7044, Business & Professionals Code). () I am exempt under Section B&RC. for this reason Date %r Signature of Owner WORKEF(r§COMPENSATION DECLARATION I hereby affir, urrider pe"alty of perjury one of the following declarations: () I have f d Will maiitain a certificate of consent to self -insure for workers' compensation, 16,9,prc2 ed for by Section 3700 of the Labor Code, for the for which this permit is issued. performance of,& work �(!) I have and will maintain workers' compensation insurance, as required by Section 3700 -of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STATE PUND Policy NO. 1542,0317-03 (This section need not be completed if the permit valuation is for $100.00 or less): () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to -'become subject to the workers' compensation laws of�California, and agree that if I should become subject to the workers' compe,nsatlon prow Visions of''tSection 3700 of the Labor Code; ] shall forthwith comply with those provisions. 4�f •Date: r Applicant ._` ` I - Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section'3706 of the 'Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director •of Building and Safety for a permit subject to the conditions and .restrictions set forth •on his application. 1. Each person upon whose behalf this application is made &each person at whose request and for whose benefit work is performed under or•pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree, to comply with all City, and State laws relating to the, building construction, and hereby authorize representatives of^this City to enter upon the above-mentioned property -for inspection purposes. Signature (Owner/Agent) - --�• H/f' Date BUILDING PERMIT PERMT# : .. DATE /VALUATIONLOT TRACT JOB SITE ��' ADDRESS .1,4 dMi�:CkY.s_11r.,La JACU A. APN 770-1:6&023 OWNE��Rpp�`pj,r*r,����y^(,Y CONTRACTOR /DESIGNER /EN1NEER 1V.C�:1diV,CAJ 1.6,t�I i. IL�.i�RC6CJ%iKi ' . CORONMJ \0)MJ[LUU301V PO BOX 389 51-105 ���1'.�1 DA VAJ -h #101 LA,QU123AA CPQ 92253 1;AQ1W. fA CA 92M (M)564-4604 CBIAP T,261 C.�✓ USE OF PERMIT RING E 44LY DWI%G .d3 1509 SF. Slr ERMIT Ll&S 1110`1" WC'.11-110t HLOCK WA)POIDUSPA. OR; 1 . slow I,5G9. FEB 0 2 F9 i„AP' R7° 465, 0.�. CITY OF I A Qt FINANCE DI 3NTA PT. Ci>AI:ITRUC'T10141EF 101.000*41€-000 �tif33,S4 PLAN CHWP V, FEE 901-000.439-318 gfiO3,.`�E FE?z DZP0aIT 1131-000.439418 1$'250,00 MRCHANICAL 1 '�i to A' 1.01-000-421-000 $92.510 ELECTRICAL FEE 101-000-420-000 $110.02 PLUMBING FFt . 101-00,0-419-000 $119.00 - 3TROMMOTID4179E AMID 1 U 1 r0004A 1.000 I f CC'M1140 ME 101-400423-000 DEVVI.CIPPA IMPACT FICE, f / saF4G5.a0 PReC13E PLAN 101-000-441345 $100.00 � SUB- MAL COMM dt>°hok AND igAw CII CK F-4 915,51 LESS PR -P. IDT— rS � 2St�aOC? .=-ALPPM r RECEIPT r� �' BY % DATF7( PECFINAL INSOR _jjlDjjjAFTE_ INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans OX to Wrap 4v F.A.U. Framing p- do Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Pibg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection - Encapsulation Gas Piping Gas Test Appliances Final -.'COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final p v Utility Notice (Perm) - -�f ilding dress Iner %'- N Titvl44Q" P.O. BOX 1504 \ 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Mailing ' Address' �, O •.� v �� City Zip Tel. I ,-L'4 y any ress City Com.',\� Zip c-/'*-, Tel �aas3 . No. ` No. Dw. r Stories Units ` State Lic. & Classif. ILticl 1 `- City �( Lic. # d c Arch., Engr., Designer Address Tel. City Zip State Lic. # LICENSED COrTR TOR'S DEC I ereb affirm that I am IiceTd unAer rovision of Chapter 9 (comma ing with Section 7 ivision 3 of the BUsi SS a P fessl Code. and my license i In full fnrce and OWNER -BUILDER DECLARATION I hereb affirm at I am exempt from the Contractor's License Law for the following reason: (Se 7 .5, Business and Professions Code: Any city or county which requires a ��,,, :?9e 74 to cons uct, alter, improve, demolish, or repair any structure, prior to Its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) cf son 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit jects the applicant to a civil penalty of not more than five hundred dollars ($500). Wecls 1 r.l I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Bulsness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I I I, as owner of the property, am exclusively contracting with licensed contractors to con. struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 17 I am exempt under Sec. B. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company (l Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith Comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to uaI'on if work thereunder is suspended for 180 days. certify that I have read this application and state that the above information is correct. ree to comply with all city and county ordinances and state laws relating to building p Onstruction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of aQplicant Date Mailing Address City, State, Zip APPLICATION ONLY LDING: TYPE•CONST. OCC. GRP. Number al Description ject Description \ /•kx \� ZONE: i Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Sq. Ft. C G Size J 1 No. ` No. Dw. r Stories Units ` New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS!;' -a YUH �tTA O Lta UIjJ ZONE: i Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date 2/2/04 La Quinta, CA 92253 No. 25439, (760) 771-8515 Owner Coronel Enterprises Address P O Box 389 City La Quinta Zip 92253 Tract # Type Single Family Residence Lot # Unit 1 15 Unit 2 Unit 3 Unit 4 Unit 5 Comments No. Street 51440 Calle Jacumba S.F. 1509 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 �c�' �ti11Ii2� O Q BERMUDA DUNES rn RANCHO MIRAGE INDIAN WELLS PALM DESERT y LA QUINTA '� ,. VQIN0 y�1 8 APN # 770-166-023 Jurisdiction La Quinta Permit # 0310-336 Study Area No. of Units 1 Lot # No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 1,509 S.F. or $3,229.26 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Valley Independent Bank - Ish Coronel Check No. 293824 Name on the check Telephone 760/564-4604 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by Sharon MCGII rey Payment Recd $0.00 $3,229.26 Over/Under Signature r NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting 7603400394 STEWART TITLE PD RECORDING REQUESTED BY: SOUTHLAND TITLE - INLAND EMPIRE (TItle) AND WHEN RECORCMD MAIL TO: Lucas Coronet Ordw No.; Sa 1371 Eac►ow No.: IN<29"c A.F.N.: 770-168•lXt7-8 rRf) 02.D 0l (_p 912 P02 SEP 18 103 12:26 Doc a ,24e to;3_1!5 [39fiet ;L 08/07/2003 0;:00q Pee: ia,@o page I R/ooro dsdJvj 01 fJolalf Z 10C T sR., Ylyds County of Itiverelde 04"Y C • Orse Assessor, County Clerk i 6110Crder 1111111111111111111111111111111111111111,1 -1,1111 11111111 _M $ u PAO& GREDA PcoR NCGOH 0A4i µ0c th U10 I EXAM THE UNDERSIGNED GRANTORGRANT DEEDS) DECLARE.(S) I� DOCUMENTARY TRANSFER TAX IS $55.00 X) computed on full value of property conveyed, or computed on full value less value of liens or encumbrances remaining at time of sale. aEA unincorporated area[ X ) city of La quintsv: FOR A VALUABLE CONSIDERATION, recelpt of which Is hereby acknowledged, Arthur Franco Sr. and Mary Hope Franco,. an unmarried man and an unmarried woman "Thereby GRANT(S) to Lucas Coronet, a single man the following described real property In the County of Riverside. State of California Lot 15 of Block 2 of Desert Club Unit No.2, In the City of La Quinta, County of Riverside, State of Callfornla, as per map recorded In Book 20, Page($) B of Miscellaneous Office of the County Recorder of Bald County. Maps, In the Dated: May 15, 2008 STATE OF CALIFORNIA COUNTY OF before me aNotary Pu I nd fors Counl ano, pets Wally e o F n to r♦-ihe-bes�of— tolbe the psrao hose name( bscribed t t within Instrumen and ackrx) ed ro mo that he xecuted the same I � authorized capaclt a and that by hal ei na w: on the Inalrument jh® pe�p,{g51or the entity upon ;0 o which the parao s acted, a ecuted the instnrment: WITNESS my t►er>�e Ci seal. Signatur atu of of 'tel MAIL TAX STATEMENTS AS(DIRarea for offici ECTED ABOVE notary seal) Description: Riverside, CA Document -Year. DOCID 2003.599601 Page: 1 of 2 Order: carla Comment: C&"�p 4 xP QU&M 78-495 CALLE TAMPICO LA QUINTA, CA 92253 (760) 797-7075 APPLICATION RECEIVED OCT 2 s 2003 PUBLIC WORKS FLOOD PLAIN DEVELOPMENT PERMIT BUILDING SITE LOCATION FLOOD ZONE "AO' - DEPTH 1 !' 1 `v \� (J e` ` COMMUNITY- PANEL NUMBER 060709 0005 3 Map Revised: 8!19;1991 ��� . o w\ �, APPLICANT INFORMATION SECTION APPLICANT NAME APPLICANT ADDRESS Q D (MAILING ADDRESS, NOT THE BUILDING SITE) - DAYTIME TELEPHONE NO. 4 6U /f INSTRUCTIONS 1. A Flood Plain Development Permit is required by LQMC Section 8.11.040(A). The Applicant should ccmplete the Applicant Information portion of this application and submit it to the Engineering Department along with the required documentation noted hereon at the,same time the Precise Grading Plan is submitted to the Building and Safety Department for plan checking. 2. Documentation required for STEP 1 OF 2 APPROVAL prior to receiving clearance for Building Permit issuance • Copy of the proposed Precise Grading Plan for review and approval .containing all information required by the checklist shown on the back of this application. 3. Documentation required for STEP 2 OF 2 APPROVAL prior to receiving Flood Plain Development Permapproval. Note, this approval occurs after forms for the lowest habitable floor are set and before the Building & Safety Department authorizes foundation construction. Submit a completed FEMA "Elevation Certificate" form to the Engineering Department. • Submit 95% relative density soils compaction certification to the Engineering Department. STEP 1 OF 2 APPROVAL SIFP 2 OF 2 APPRO)LA The Precise Grading Plan submitted for this application has been All requirements have been satisfied. Thu Flxd Pla.", reviewed and found to contain all data required to satisfy the Development Permit is approved. requirements of LQMC 8.11 The proposed dwelling is eligible to receive.a building permit upon satisfying all other Building & Safety Department requirements. 18710 AUNHORIZEO SIGNATURE DATE AUTHORIZED SIGNATURE DATE La Quinta Engineering Department La Quinta Engineering Department FILE: upon Step 2 approval, original goes in "Flood Plain Development Permit" file; copy goes to Applicant PLAN C U PCN Please e t Is PI n itheck Number (PCN) F090 REV -2 on all correspondence while plans 7= are in Alan check U c OWNER: rA oulNIA A 7 65 (1-i ) 5)6 4 -- h I 1 )4 LEGAL OESCRIPTION: 10T 15, DESE OVR M& , -, 11) 1' ) lift, SITE ADDRESS: ASSESSOR'S PARCELN0: he BASIS OF BEARINGS: 1 , �_ILI.1- - dAc-UMBA -FAITER' v IN'_ F A L BENCHMARK: roF OF -)A I I FHE BCP OF A t/t, LA FONDA AND CALLS" ILOILO, ADJACENT I-0 LOT 21, PER Ti -/C APPROVED STREET PLANS, BEING 033.30 TC) ALL CLEV ;)N,�_, , ` ( ATI,-'- THE NCOID-29 CONVENTION L.0)r 1 6' No TE: (XIANFITIE-c7 ESTIMATE SHOWN /5 F—I )R PERMIT PURPOSE51 j - 1T , RE-SPONS11BIL17) I() ONL'r, THE- CONTRA(, TOR'<-- OFIERMINE Tk-!F QUANTITIES FOR H15 BID AND FAYMENT 0 t _,A N I / T I ES EST71WAITT' 0OFS, NOT INCLUDE __LEAP1N6_, -;I )NICE 0 f - -) S�F AN'1- TPE�' LGS S, OR AW, 'R t//1 rh-W COVC�ED UNDER A SEPARArt- � ADIINI(� O/;� r' ! f PERMIT EARTHWORK QUANMVES ESTIMATE: 4L rm/popr/ 11L0 —TEL ALL FILL MATERIAL PLACED) UNDER SHALL BE COMPACTED TO 1\11NETY—FIVE- Pt7RCFAIT 57 RELA TI VE DENSIT'K FLOOD ZONE DESIGNATION: _'UP RA TF W) x /NS ANCE MAP (F/r C OMMUNIP, PANEL WAIIBEP 0&01 09 0005 8 DATEO A,/_1(_,'U5T 1991 ZONE AO, DF PTH I F"(')(_,)1/, -CITY OF LA --- 'ADI NC VoTE-: I, GRADING SHALL BE IN ACCORDAW"E WITH THE ENGINEERED GRADING REQUIREMENTS-- OF THE UNIFORM RIJILDINC CODE, LATEST FOITION, AND SOILS REPORT: NCI DATED:_ PREPARED) BY,- TELEPHONE p S) ENGINEER AND THE ENGINEERING GEOLOGIST SHALL EXERCISE THE SOIL -IFFICIEN T SUPERVISORY CONTROL DURING GRADING TO INSURE COMPLIANCE WITH THE PLAN -S., '._)PFC1FICAr1O.N_S;, AND ('-"ODE' WITHIN THEIR PURVIEW. 3. THF OESIGN -VIL `--,HAt_f EXERCISE SUFFICIENT CONTROL DURING GRAD1N(__,' AND TO INS`JRF COMPLIANCE WITH THE PLANS, S, AND CODE WITHIN H/) PURVIEW - r DURING ROUGH - GRADING OPERAIIJONS AND PRIOR R-) CONS/`RucnoN OF ,44*iNr:DRMIAGE STRUCTURES, IT"MPORARY DRAINAGE CONTROL SHAIL BE PROVIDED TO PREVENT PONDING WATER AND'OAMAGE TO ADJACENT PROPERT), 5- AFTER CLEARING. EXISTING GROUND SHALL, BE SCARIFIED TO A MINIMUM OF 6" ON THE ENTIRE SITE OR AS RECOMMENDED BY THE SOILS REPORT. 6. THE MAXIMUM CUT AND FILL SLOPES SHALL BE 2: 1 r 7, PADS SHALL BE COMPACTED TO A MINIMUM OF 97, 0,RELATIVE DENSITY PER R A,5.T.M. SPECIFICATIONS AND THE ABOVE MENTIONED SOILS REPORT 8. MINIMUM BUILDING PAD DRAINAGE SHALL. BE ",%1. ORAINAGE •SHALL BE_ -A MINIMUM OF 0..3' DEEP AND BE CONSTRUCTED A M1NhWU,1V OF FROM THE 'FOP OF CUT OR FILL SLOPE-,- jHE MINIAllUtV SLOPE OF S)WALES SHALL RE 0.F. ,1`4 5. 92 TVV�, LEGEND & ABBREVIATIONS: 9. ALL FILLS SHALL BE COMPACTED TO A MINIMUM OF NINETY(90 PERCENT OF CEN TE RL INE MAXIMUM DENSITY AS DETERMINED BY THE U1\11FORM BUILDING'' ("ODE SECT10,61 FENCE ATOP F PROPERTl LINE 7010 OR EOUIVALENT AS APPROVED B)- THE CIT?' ENGINEER. FIELD DENSIT7 RETAINING WALL HP Hh-H POINT SHALL BE DETERMINED IN ACCOROANCE W11H THE UNIFORM BUILDING CODE <-r0 , C, t6=) I-) SECTION 700z`i", Of? EQUIVALEK AS DETERMINED BY THE Clpr ENGINEER EXI� IM' .'LAB ANL) _FXISTING rg - , 41_50 TW,31WE 13REAK 6L_0CjA WALLS TO &E EXISIft. W0�_/NE ELEVATION ON LOT\ 5 40,47 FF) 1� r,, -- _)AW ---('NT ANO 0, 0 1 Fc; _!NI STREET DECrION5 ARE TENTATIVE. THE MINIMUM SECTION IS .3" A. C, 6) VER Tr- 10. ALL ." TRE. I I IN G, _39.5 TF -SH GRADE 4�5" CRUSHED A.B_ ADDRIONAL SOIL ITST(S) SHALL BE REOUIRED AFTER W60D HFAD' r c (4 0 1 Tt: It— — _j FINI-Sh' -SURFACE" 'RADING TO DETERMINE EXACT Cl T`- -4T 7,— - r ROUGH 6, SECTION REQUIREMENTS rh1F lNi-H FLOOR FLEVATION T„15rING CONCR47E PAr1(_1 I -c F ENGINEER SHALL APROVE" THE FINAL STREET SECTION. PAL) tDAI) ELEVAT/Oi\j PLA NTErrc' P 1 7, 1, 7_ F 1. 1 ) THE Cl TY' ENGINEER WILL REVIEW FOR APPROVAL THE- FINAL STREET SECTIONS 00 00 1 1 QIT FG W. T'P _)F- WALL 11, '(40,30 F5) zz 7Ai TESTS FOR q(--)AOWAf' 5 UBBA S B, w R(_ T-FOAll OF WALL AFTER SUBMIT - OF 'R VALUE T. F TOP OF FOOTING _? TESTS SHALL BE DETF- reiWINED B)' ME SOL (4 1"0.95 Fi �,'/w BAC�< OF WALK 12, LOCATIONS OF FIELD DENSITY - )r-- ENGINEER OR APPROVED FEST AGENCY AND SHALL BE SUFFICIENT //N/ BOTH TEXISTINI R/GH: c r WA 'I" F� Vv U _AL PLACEMENT TO PROVIDE REPRESENTATIVE TESTING HORIZONTAL AND VERrh- �j9�65 F WIRE FA�`NCE TING IN AREAS OFA cRln(.,AL HIGH r ADJACENT GRAOC If 5 -NI? [)/W V6 A V '14 OF ALL FILL PLACED. TES EXISTING CHAIN ToP OF URB NATURE OF SPECIAL 40. 27 F'_ �,EMPHAS15 SHALL, BE IN ADDITION TO THE NORMAL FIL. l LOW LINE 'A 1,85 r LINK FENCE REPRESENTATIVE SAMPIINGS. 5 E P. ED (-,'C OF .Cd TINS' FAVt_ME1\IT N PA VEMEN T It "HE FINAL _)MP, 'NGINE ER EXISTAI G A RA G E TOP of u 'ACTION REPO' T AND APPr AL. /70M THE �501L E e 40.3.3 FS BLOCK 4' T.C. TOP OF GRA TE -WE OF FIELD TE5T(Nt' PERFORMED. EACH TEST SHALL BE ALL :J" LL CoNT41N THE' T -IDENTIFIED WITH THE MER -10D OF OBTAINING THE IN-PLACE DENSITY, WHETHER D) _J J I INV INVERT CLEVATION �,39.71 FLREMOV E 1, 60 FS SAND CONE OR DRIVE RING 51 -IA LL BE SO NOTEO FOR EA CH TEST. "63 Ck-TISELED ON C UR BE LkE (40 1 11G) 16-1 LOWE5T HABITA SUFFICIENT MAXIMUM 0ENSIT'Y DETERMINATION 51-IALL BE PERFORMED TO VERIFY' INI-SkI FLOOR ELF/ 4 1,25 F1 "S CHISEL ED ON CURB CURVE, US -D BY THE FIELD TEC 11CIAN -4 ',- 2 Oi_'� (_'HISELED ON CURB THE ACCURACY OF THE MAXIMUM 0ENSlI W/,` _L EV _r L_ J 4ci _,j(40,0 E�() L_,CI._ ELEVATION TION 14. ALL UNDE?GROUNO FACILITIES, WITH LATERALS, SHALL BE IN PLACE AND INSPEC7ED FOLLOWING,- -)P( ELEVATION 4 '45 F�_� <_,,::1 Q PRIOR TO PAVING, INCLUDING BUT NOT LIMITED TO THE P R ' )'ED t,,O T 41:951 FS SEWER, WATER, ELECTRIC, GAS AND DRAINAGE LINE RIGH F- C)F WA f'S 42 *-0 0" - --- ----- P-dO, 15. THE FINAL UTILITY LINE EACKFILL REPORT FROM THE PROJECT SOIL ENGINEER SHAU 41.40 FL CONTOUR STATEMENT THAT THE BACKFILL IS SUITABLE FOR THE 17 87 41.50 PADrIF FX1' FIN(, INCLUDE AN APPROVAL STATE 1 CONTOUR FIIVIS� IN TE _)RAINAGF 'WALE r�E16. BLOCK WALL.- ARE NOT FART OF THE GRADING PERMIT BWIT Fr "CPA, RA TE -A A T(,p _�L OP E )R E )<ISTING lNISH SLOPE BUILDING PERMITC-1 X15TING' 6' -IRS Top AND 64,11 R FTC, J. 1 EG) ----------------- THE C'ONTRACTOR REPSONSIBLE TO PREVENT SILT CONTAMINATION OF (40 E-Xl"-)'TING CURB AND GUTTER' RETIVNIN - _9 F,,'.- OTING _TORM1 _R INFILrRATION FAC'AITIES DURING CONSTRUCTION OF' /VF IYA TE ;0 0 1(-- G 11WAL LIDEEPL L 1.54 Fc, zol -)SION PPOrL'-(" TION SUBSEOUENT ItIlIPROVEiko'ENTS 19� I PE COWRACTOR. IMMEDIATEL'I PRIOR rc) FINAL _40 60 f(I I00OL) ER( STORM DRAINAGE RETENTIONIINFILTRATION FACILITIES, ZZ m1a, 3--3ct'i7rIZ-1�211 —'-== ACCEPIANCE Of 47 K WA L L W OF THE CITY' INSPEC70-R, L i EXISTING BL0(_ 7717-7-j 7 � I.0 U t"L/ -1A 4" THE CONTRACTOR 55� LL CONDUCT, IN THE PPESEJ 4 6� _50 ------- — 777=_ PROPO-SED RLCICK WALL A PERFOR)WANCE TEST DESIGNED TO CLEARLY DEMONSTRATE THE FUNCRONAL 40 '30"2j' FXI'rING 41.25 FG1 ADEQUACY OF THE FACILITIES. 0 �: -I 1, 6-2 FF SL66,�wxlo `THE FL, r c: '18. THE CONTRACTOR SHALL PROVIDE WIND EROSION AND OUST CONTROL MEASURES DW7 )L PLAN Ar' OVED FOR THJ,�'_ ONCRETE AS REQUIRED Br'" -IE' FUGITIVE 5 T CONTR( r PR PROJE( r C L UMN METER N E"i WA TEh N.- LO x - pr F1 r HYDRANT T 14 q POWER _R POLE v" VIA TER VAL VE _S cm t, C'N - (b IRRIGATION CONTROL VALVE Underground "Icirvica, Al -art TOLL FREE Cull. P, 1-800 AV 2 —2600 27 j T"No 1V1X1WXjtj(1? WXY5 ®rEf,02E,_ Itoij DIG (;f)NAPHIC SCALF r. I nich 7 10 f L m rE I INITIAL /? 0 Vt D BY, TIMOTHY R. JO1N1Ac5_SrW I t- DATE PUBLIC WORKS) _( TOR CITY EER R.C,E 4584� L P. 121,31106 - ),t The Cit -y -of La Q,u-irt. 41-625 Edo,�Wc St, Suite c' to 91fEr I,,(), I of -1 Civil Engineering Pulm Desert, California 921260 _i- Man OECj7G11N11 6,K: Land Surveying (160) 546-8015 P r e cia e, G-4 r ac fin g Fox 1760) 34654FJ V AWN BY Dec'er` iJob 7_r" -I-f OC Copyriqht 2003, farm Enqin�eiLntj, Inc DA TE_� 'WPf 0 -k 3' T F R UND - 7-�5u-prR_—V1S1&1 cv Fr XIR 0 wt C to et n e I C o GI -s NEER, OL N (3, i CHI�CK PRINT# 2�, 6)-y140 C-Attf )WAigA- Title 24 Report for: Coronet Enterprises Villa Bellagio - All Orientations • La Quinta, CA Project Desig 0 CITY OF IA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA's �.� 3 By ST_ 0 CFTC C -r Report Prepared By: Joan D. Hacker Insu form, Inc. 68-255 Corta Road Cathedral City, CA 92234 (760) 324-2046 Job Number: Date: j 8/20/2003 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report: This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft. LLC (415) 883-5900. EnergyPro 3.1 By EnemySoft Job Number: User Number. 2655 i TABLE OF CONTENTS Cover Page Table of Contents 2 Form CF -.1 R Certificate of Compliance 3 Form MF -1R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 13 i i - I i , I i i I I I jIII I f , i - EnergyPro 3.1 By EnergySoR Job Number. User Number. 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R C0tz0t4V-_L Ei-MsE_S 8/20/2003 Projed Title Data Villa Bellagio - All Orientations La Quinta Project Address Building Permit d Insu-form, Inc. (760) 3242046 Plan Check / Dace Documentation Author Telephone Computer Performance 15 1 Field Check / Date Compliance Method (Package or Computer) Cum ate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1.509 ff Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 1,509 It Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Const Frame Assembly Location/Comments Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-13 Wall w/1" EPS Wood 0.059 Exterior Wall Solid Wood Door Norte 0.387 Exterior Door R-38 Roof (R.38.204.16) Wood 0.028 Exterior Roof Front FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U-F2ctor SHGC Shadin Yes / No Yes / No Front 33.4 0.85 0.70 Bug Screen ® ❑ ❑ Leff 320 0.75 0.62 Buq Screen Q ❑ ❑ 0 Rear 13.5 0.61 0.63 Bug Screen Q ❑ ❑ Rear 40.0 0.78 0.63 Buq Screen X❑ ❑ ❑ Q Rear 16.0 0.75 0.62 Bug Screen X❑ ❑ ❑ Q Right 40.0 0.78 0.63 Bug Screen 0 ❑ ❑ Right 24.0 0.75 0.62 Buq Screen X❑ ❑ ❑ 0 ❑❑ ❑❑ El 0 E ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run in an Time,- RUM 14*18v58 Run Code: 1061414338 3.1 By EnwaySaft User Number. 2655 Job Number Paw.3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Coronel Enterprises 10/21/2003 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Cpntral Fiirnare 80% AFUE . Ducts in Attic 42 Setback Living Zone Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc.) Duct Thermostat Location / R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethack Living 7nne WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A G SMITH PGM -150-926 Small Gas Standard 1 40,000 so 0.62 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS GumrLtANUL J t A I tIVItN I' This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Address: Telephone: Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Name: Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 68-255 Corta Road Cathedral City, CA 92234 Telephone: (760) 324-2046 �,a; (signat re) (date) (signature/stamp) (date) Run Initiation Time; -10/21/03 21 00 50 Run Codes 1066795250 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:4 of 13 Certificate of Compliance: Residential (Addendum) CF -IR GaP-c�NEI_ i�T�P�I�g Project Tree 8/20/2003 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified In this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies .......... — -.o --"--Y v...w r -k— Jwun..auu.. amu uUGurnrCrl{anUn SUDmlAea. HERS Required Verification These features must be confirmed and/or tested bbl a certified HERS rater under the supervision of a CEC approved HERS Plan I Feld .............................�......�............a... YIV ..¢.0 OC....Gauun amu awenosuc Iesung or mese measures on a Torn cF-§R. Plan Field The HVAC System "Living Zone" is using reduced duct leakage to comply and must have diagnostic site g testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported ona' CF -6R Form. EnergyPro 3.1 By EnergySoft User Number. 205 Job Number. Paae:5 of 13 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -IR NOTE: Lowrse residential buildings subject to the Standards must contain time measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements fisted on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere to the documents or on this cheddist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA If not applicable DESIGNER ENFORCEMENT Building Envelope Measures a '§ 150(a): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturers labeled R Value. 4150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does Qnot apply to exterior mss walls). F] ' §150(d): Minimum R-13 raised floor insulation In framed floors or equivalent ❑§ 150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 pemJnch. Q§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. LAW 6116-17: Fenestration Products, Exterior Doors and Irfiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weathersbipped: all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures a§110-13: HVAC equipment, water heaters. showerheads and faucets certified by the Commission. © § 150(h): Healing and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑X §150(1): Setback thermostat on all applicable heating and/or cooling systems. FV1§ 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.56 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other Indirect hot water tanks have R-12 external insulation or R-16 combined intemallextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. n., c„e...,,c..n user Number ?ass Job Number. Page:6 of 13 cnniayrro v.. —. —.._ o, Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1R NOTE: Lowrlse residential buildings subject to the Standards must contain these• measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements fisted on the Certificate of Compliance. When Otis checklist is incorporated into the permt documents. the features noted shall be considered by all parties as minimum component pertonnartce specifications for the mandatory measures whether they are chnwn AlcnwherA In the documents or on this checklist oniv. DESCRIPTION Instructions: Check or Initial applicable boxes or enter NIA If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) -§ 150(m): Duds and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 63; duds insulated to a minimum Installed level of R-4.2 or enclosed entirely In conditioned space. Openings shag be seated with mastic, tape. aerosol sealant. or other dud -closure system that meets the applicable requirements of UL181, UL181A, or UL1818. if mastic or tape is used to seal openings greater than 1/4 inch, the combination of mash and either mesh or tape shag be used. Building cavities shag not be used for conveying conditioned atr. Joints and seams of dud systems and their components shag not be sealed with cloth bade rubber adhesive dud tapas unless such tape is used In combination with mastic and drawbands. 2. Building cavities. support platforms for air handlers, and plenums defined or constructed with materials other Ohara seated sheet metal, dud board or flexible dud shag not be used for conveying conditioned air. Building cavities and support platforms may contain duds. Duds installed in cavities and support platforms shag not be j compressed to cause reductions In the cross-sectional area of the duds. t 3. Joints and seams of dud systems and their components shag not be sealed with doth back rubber adhesive ! a dud tapes unless such a tape is used in combination with mastic and drawbands. i 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have egherautomatic or readily accessible, manually i operated dampers. i 6. Protection of Insulation. Insulation shag be protected from damage, including that due to sunlight, moisture, , equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable I I for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coaling that is water retardant and provides shielding from solar radiation that can cause degradation of the material. i If § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch• weatherproof operating instructions, no electric resistance 1 heating, and no pilot 2. System is installed with at least 36' of pipe between filter and heater for future solar, cover for outdoor pools or 1 ! spas. a. At least 36' of pipe between tater and heater for future solar heating. 1 b. Cover for outdoor pools or outdoor spas. 's 3. Pool system has directional inlets and a circulation pump time switch. i §Irv, i115: Gas fired central furnaces, pool heaters. spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Nonelectrical cooking appliances with pilot < 150 Bhutan) I §118 (f): Cool Roof material meet specified criteria I I Lighting Measures 1 ® §150(k)1: Luminaires for general fighting in kitchens shall have lamps with an efficacy 40 lumenshvatt or greater for general lighting In kitchens. This general lighting shag be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. C §150(k)2: Rooms with a shower or bathtub must have either at least one lumtnalre with lamps with an efficacy of i 40 lumens/watt or greater switched at the entrance to the room or one of the af0emative to Otis requirement allowed in Section 150(k)2.; and recessed calling factures are IC (insulation cover) approved. 3.1 By EnergySoft User Number 2655 Job Number. Page:7 of 13 Computer Method Summary (Part 1 of 3) C -2R GoRoN�L Ei-sTPtaSF S 8/20/2003 Protect TWe Data Villa Bellagio - All Orientations La Quinta Project Address Insu-form. Inc. (760) 324-2046 Building Permit 0 Documentation Author Computer Performance Telephone 15 Plan Check/Data Freed ChwJdDate Compliance Method (Package or computer) cimate Zone Source Energy Standard Use (kBtu/sf--yr) Design Space Heating 1.46 Space Cooling 34.92 Domestic Hot Water 15.70 Totals Facing North Margin Facing East Margin Facingacing South Margin West Margin 1.12 0.34 35.69 -076 13.13 2.57 1.49 -0.02 35.24 -0.32 13.13 2.57 1.26 0.20 35.72 -0.79 13.13 2.57 0.97 0.49 36.86 -1.94 1313 2.57 BUILDING COMPLIES This C-211 summarizes the results of a torr cardinal orientation anatysis. The pages that follow describe the front facing North ooamenoe. . This plan has been analyzed with identical features in all mtentatons. GENERAL INFORMATION ❑X Slab Floor Conditioned Floor Area: 1,509 Floor Construction Type: ❑ Raised Floor Building Type: Single Fam Detached Building Front Orientation: All Four Orientations Total Fenestration Aea: 13.2% Number of Dwelling Units: 1.00 Total Conditioned Volume: 13,581 Number of Stories: 1 Slab Floor Area: 1,509 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type HgL Area I Wing Zone ? 1358 1 Uo Conditioned Setback —2 —0 OPAQUE SURFACES Solar Act. Gains Type Area U Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 3 of 3) C -2R 609c*-�EI-8/20/2003 Project Tltle Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (n.) Cap. Cond. Form 3 Reference R Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R Val. Depth Location / Comments Slab Perimeter _ZZ 0a 0.0 0 Wing Zone Slab Perimeter _ 21 0.76 0.0 0 L'ivingZone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R Value Type Comments Central Furnace 80%6 AFUE Duds in Attic 4.2 Setback Living Zone Hydronic Piping Pipe pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R Value Type Comments ,Split Air Conditioner 12.0 SEE Duds in Attic 4.2 Setback Living Zone WATER HEATING SYSTEMS Rated/ Tank Energy Fact?? Tank insul. Water Heater Water Heater Distribution # in input Cap. or Recovery Standby R -Value System Name Type Type Syst (Btu/hr) (gal) Efficiency Loss (%) Ext. A O SMITH PGCG50-226 Small Gas Standard —1 40.000 s0 0.62 n/a n/a ? For small gas storage (rated input <-- 75000 Btu/lu), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btulhr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R COF-oN v-= PL � S .1 8/20/2003 Project Title Deft Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written Justification and documentation, and special verification to be used with the performance approach. The local ....s..�..........t �..e......tete....i..ec the OW tha iunfifirsfinn_ and msw Mad a building or daslon Bud otherwise comolies wed on the adequary of the special justification and documentation submitted. Pin Field HERS Required Verification r.e@e �st...eQ .....at he .•.,..it....u.1 amt/nr feefad by a roafified MFRS rater imdar fha AimarvLainn of a CEC aanroved RSM provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -R. Pian Field The HVAC System'1.iving Zone is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a oertilied HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Iniflabon Time: 08120103 14:18:68 Runde• 1061414338 1 E wWpro 3.1 By Enewsoft User Number: 2855 Job Number Pagel I of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME C09o441---L SV TEQPR5eS DATE 8/20/2003 SYSTEM NAME FLOOR AREA Living Zone 1,509 NGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 92.000 Total Output (Btuh) 92.000 Output (Btuh/sgfy 61.0 Cooling System Output per System 48.000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btoh/sgft) 31.8 Total Output (s4ftrron) 3772 Air System CFM per System 1,995 Airflow (cfm) 1.595 Airflow (cirnisgft) 1.06 Airflow (chnfTon) 398.8 Outside Air (%) 0.0 Outside Air (chWsgft) 0.00 ote: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 of 69.3 of 69.3 of Outside Air r-- 0 cfm 69.3 OF 11.9 / 77.6 of , Outside 0 dm 78.8 / 65.9 of 3.1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM I Sensibiel Latent I I CFM I Sensible 30 3 27059 BDP CO.563AN048-A 3ZI07 11,192 92,000 Total Adjusted System Output32,1 11,192 92.000 WAtsWd fm Peak Design ConMom) TIME OF SYSTEM PEAK AM 2 pm Jan 12 ar eam Temperatures at Time of Heating Peak} - 123.5 of Supply Fan Heating Coll 1595 dm Supply Air Ducts 1228 of ROOMS 70.0 of Retum Air Ducts 7&8/65.90F 78.8 / 65.9 of fla 59.9 / 58.9 of Supply Fan Cooling Cog 1595 c frn User Number. 2655 Retum Air Ducts Job Number. S Supply Air Ducts - 60.7/59.1OF 5Z.4% R.H. ROOMS 78.0 / 65.7 of 12 of 13 ROOM LOADSUMMARY DATE 8/20/2003 �ROOM LOAD SUMMARY •'• �� F• • • M•'• •.. TOTALPAGE 1.4921 27.4701 3.M 1a TOTAL 1 1,4921 27.4701 3,nB 4381 24,5991 E. gyPm 3.1 By E emySoft User Number. 2655 Job Number. Pagw13 of 13