Loading...
0110-095 (PAT)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and ProfeFdsionalsC ode, and my License is iri full force and effect. License # A Lic. Class Exp. Date Date Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: *.) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044; Business & Professionals Code). ( ) I am exempt under Section B&P.pifor this reas n ,Date Signature of Owner YCri. s ri +1. titer:. WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). I certify that in the pertorriiance of the work for which this permit is issued, IA shall not employ any person in any manner so as to become subject to the Workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with hese provision Db�ate: � 110 Applicant . Asc s 4�, !'Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil. fines up to $100,000, in addition to the.cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT.Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of.this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representativesof this City to enter upon the above-mentioned prope for inspection pur oses. �*--- Signature (Owner/Agent) AA'4 - ar' Date Q 1'60 Qf BUILDING PERMIT PERMIT# t�dt DATE VALUATION LOT �'a'� TRACT JOB SITE�� y-�, ADDRESS SS . PI 1A PALMA D � APN OWNER CONTRACTOR / DESIGNER / EN (NEER EVY'al r. KY&TAR?U'.A1` EYH MC23 '601,'. 4 T Gi RIFI'� f ,W i. 71ZER *R C.O�syA PATZNI. ADR q�� QUA114dA, 4 r 92,2:e 3 . C.13LO USE OF PERMIT k'.t00 490 SA x .lD,`i'4 CE PATIO COVER PpbR,. f.,lTY ST.ANDARV, PORCJ3MA:TIO 430,99 SF PLAIN C'HYCK FH9STRON10 MOTION FZK - PS 101-000-2,41-000 ?"M =C,2001 CITY OF LA QUINTA FINANCE DEPT. 149.14 RECEIPT DATE BY DATE FINALED NSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR " BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts ForM & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap Framing _ F.A.U. Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Q//o 1i 8� BLOCKWALL APPROVALS Final POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping. Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: OWNER / BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "Owner/ you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. i If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200.00 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the State and Federal Government as an employer and you are subject to several obligations including State and Federal income tax withholding, federal social security taxes, worker's compensation insurance, disability insurance costs and unemployment compensation contributions. There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Adminstration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/ Builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you arc aware of these matters. The building permit will not be issued until the verification is returned. Very truly yours, - CITY OF LA QUINTA --- DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico La Quinta, CA 92253 (760) 777-7012 FAX 760) 777-7011 �O0� OWNER'S SIGNATURE/ DATE i` ? 1�9 LoD UA PARVA �2 PROPERTY ADDRESS PERMIT NUMBER(s) J40L,.S, STz€ C4 A 5 CIAHOO gvc,�eSrr LA 0U1NTA EpT FET gU1LDIt�G & SA FSR CONST 78960 La Palma Dr BY La Quinta, Ca 92253 pA�a f When the concrete patio deck was poored, holes were dug for the post holes so that a five gallon bucket would fit in the hole and be completely submersed. The five gallon bucket was not left in place when the concrete was poored. The concrete slab is just over 5 inches thick. RAFTER SWIM SPACING ROOF PITCH Y ROOFING AND SHEATHING OR OPEN LATTICE (SEE ROOFING NOTE ON REVERSE) - - _! � ? c- 0- � -A-- mm 0- In 7 NOTE: OPEN LATTICE PATIO COVERS MAY BE ATTACHED TO EXISTING (FASCIA VIA ONE 1/4' x 5" LAG SCREW THROUGH FASCIA. INTO EACH RAFTER TAIL 3/8 x 5' LAG SCREWS INTO STUDS AT 16" O.C. �- CONTINUOUS LEDGER JOIST HANGER OR SOLID BLOCKING NAIL RAFTER TO BLOCKING BUILDING DEPARTMENT APPROVAL BELOW CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPUVE® FOR CONSTRUCTION DATE 10 • fS -CDL BY wu U -STRAP OR ANI NON -CORROSIVE (4)- 16d NAILS OR BOLT PROVIDE I" CLEARANCE BETWEEN POST AND CONCRETE —, U—STRAP OR ANGLE (4)— 16d NAILS OR BOLT PROVIDE 1" CLEARANCE BETWEEN POST AND CONCRETE ANCHOR BOLT (EMBED — 7" MIN. INTO CONCRETE) •Rj TYPICAL PATIO COVER DATE OF APPLICATION 0110013 9 1 0 0 Q3 OWNER'S NAME C.1�� o STREET ADDRESS -7?9(0-0 LA PA Lm,^ bit CITY. ST ZIP � �/A „ zJ J I �, L. -W lX Q225- 3 TELEPHONE " H.O.A. APPROVAL RAFTER SPAN TABLE AZ GRADING RULES S� 'T C_-) O� PS 20-70 V G v 4 (FEET & INCHES) ooJ��i . 0A, o_0 A, 2x4 16" O.C. 24" 10'-6" 9'-6" 1 T-3" 8'-9" 8'-6" 8'-0" 6'-0" T-3" DOUGLAS FIR NO. 1 SIZE i 2x6 16" O.C. 24" 32" 15'-0" 14'-0" 10'-9" 13'-0" 12'-6" 11'-6" 8'-9" 10'-6" 10'-0" 8'-6" 1 N/A N/A 4x8 2x8 16" O.C. 24" " 32" " 18'-0" 17'-0" 13'-6" 16'-0" 15'-6" 14'-6" 1 11'-0" 113'-0" 13'-0" 11'-6" 1 N/A I N/A 4x 1 2 NOTES: 1. 32" RAFTER SPACING IS ALLOWABLE FOR OPEN LATTICE PATIO COVERS ONLY. 2. FOR SOLID PATIO COVERS (NOT LATTICE) RAFTER SPAN IS LIMITED TO 10'-0" USING THIS STANDARD. L ATTICE ROOF BUILT-UP ROOF HEADERS HEADERS DOUGLAS FIR NO. 1 DOUGLAS FIR NO. 1 SIZE i SPAN SIZE SPAN 4x.4 5'-0" 4x4 4x6 8'-0" 4x6 4x8 1 1 '-0" 4x8 8'-0" 400 14'-0" 400. 10'-0" 4x 1 2 17'-0" 402 2 1 2'-0" 6x8 14'-0" 6x8 1 ^'-0" 600 17'-0" 6x10 ALL CONSTRUCTION SHALL CONFORK TO THE PROVISIONS OF THE: 1998 CALIFORNIA BUILDING CODE. 1. , x • SUPPLEMENTAL NOTES: ROOFING NOTES: A. BUILT-UP, ROLLED ROOF: SLOPE TO DRAIN. B. ROCK ROOF: 3/12 MAXIMUM PITCH.