Loading...
BWFE2015-0029' : a 78-495 CALLE TAMPICO T4'y,,, 4 4aum ro LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BWFE2015-0029 Property Address: 80073 CHAMPIONS WAY APN: 775370016 Application Description: 166 LF OF COMBO WALL Property Zoning: Application Valuation: $10,375.00 Applicant: ULRICH SAUERBREY 74948 LIVE OAK STREET INDIAN WELLS, CA 92210 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: BB License No.: 927267 Date:! 2" ? 5 Contractor:® OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the ohtractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Nam Lender's Address: Owner: LQR GOLF 1 BUSH ST STE 1100 ill' 28 2015 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 CISCO, CA 0 Date: 1/28/2015 Ty�1--�."��+:r'fia Zvi. .lEyEiO� 1NTA CALIFO NIA WEST CONSTRUCTION I HIEN' DFP fp IESTLY DRIVE STE 110 CARLSBAD, CA 92008 (760)918-6768 Uc. No.: 927267 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the k for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become s bject to the workers' compensation provisions of Section 370 of the Labo Cod , I shall forthwith comply with hose provisions. Dat --L-2gApplicant: G WARNING: FAILURE TO SECURE WORKERS' COMPENSATIO(SAND VERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALT CIVIL F ES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDTO T OST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this cit to enter upon e a ove mentione property for inspection purposes. Dat 7 Signature (Applicant or Agent :0 ` A CITY OF LA QtffK BUILDING & SAF APPROVED FOR CONSTRUC CIOI DATE, 0 d—, EY Q 2" CAP 114 VERT BAR 0 32" 0/C 0 CENTER OF 6" CMU W/ 24" MIN. £XT. INTO 8" CMU BELOW. tamer MUTS/MCM TV M20XPDMR MAS7MC476 A'XiTDM46ri0M* 4MIM N. WIAX WAT17,WWWPAA0 FRWWrA MLASG7l1 PBMWM FM MYA70TAY•GSST AG176TMrUWS= ANAErADmM'WALM carMSRS;OUM.SAO a4a=L SYDZWM vCFSOS BMm iaL MWMAASTMW1 AW&PAI' AWAON'A59021ML WATMMW84ME, MEQ° WILL W 0JF%ATswnP'QQ /ROYIDIEmomwavAwvutm LEVEL BACKFILL' DEiTGY OUTERL , PER 2013 CDC 1.5101LBFARIMGPRERRM-2500PSE. H'JUIYALDtITRLOO PRESSURE • 40 MI PER SOn RD30RT Z AVOWABLE UTHIAL PASMW FRESA/RE.150 PSE• 1 _ 1 GROUT SIRWYN - 2000 PST 028 DAYS 4. -�! I Q I500PCW STEEL: MOM. SY ASOMYCOMPRESA-I SECOONb7REmm. -1 J4 - HORZ. CONT. ® 24" 0/C 8816 CMU SOLID -. GROUTED W/SPCL. INSPECTION REOD. CLR 'G' BAR 0 EDGE OF �— 8" CMU FULL HEIGHT NOTE. PROVIDE LEM ONE SPECIAL INSPECTION PER COC TAKE 1704.5.1 OF THEMASONRYSTEM PRIOR TO GROLMNG 70 VERIFY GRADE, SMEAND PROPER PLACEMENT OF Rt7NR7RCETIENTAND TO ENSURE THE GROUT SPAC E IS THE PROPER SIZE WITHOUT OBSMLX770N OTHER THAN NORMAL MORTAR FNS, (2) If 4 HORZ CONT. ® 24" OIC PGA WEST/LA QUINTA F" DOWELS ® EDGE TR. NO. 36537 i� OF 12" OR 8" CMU 12816 CMU SOLID GROUTED W/ SPCL. INSPECTION REOD. 4" DIA. SDR 35 PERF PIPE W/ 12" OF 3/4' GRAVEL WRAPPED W/ MIRAFI 140N t , ,• ;� FILTER FABRIC EXTENDING UP TO 12" OF FINISH GRADE - 2Z SLOPE TO DRAIN PROVIDE OUTLETS 0 100' INTERVALS • _N V 5' TO DAYLIGHT x,12» W BAR 14 HORZ. CONT. ® 12" O/C 0 TOP & BOTTOM OF FOOTNG. 44t 'A ' 'B' 'C' 'D' 'E' 'F' D 0 WEL 'G' VERT 'H' BAR. 2'.0' 2'-0'= N/A 2'-6" NIA #4®32" O/C x'33 NIA 4®32" 0/C �_ ' 12" 6 "_ 2'-8' 2'-81) NIA 2'-9" NIA #4032" 0/C 41 N/A 4®32,, 0/C 27 12" 6,1 3'-41 3'-4" N/A 3'-0" N/A #4032" PIC 49. N/A 4032" 0/C 12" 61, 4'-0`14J-01; N/A J' -J"'4" #4016" 0/C 57' N/A 4016" 0/C �_ 12"6" 4'-8' 4'-8" N/A 3'-611 611 #4O16" O/C I65' L NIA 5®16" 0/C � ,151-4` 121 6- 51- 4 " 5•-4;• N/A 3'-9„ 9„ #5016" 0/CI'73' N/A 5®16" o/C �_ 12" 6' 6'-0' 4'-0" 2'-0'` 4'-3'' 10"' X5016" 0/C 33 #4016" 0 C / 5®16" o/C F _ 12' L 6" combo RETAINING WALL PER SECTION j-.7, K -K AND UPPER WALL ON SECTION N. RETAINING WALL NOTES: MATECALS. A WALLSSHOULDBEGROUIEDAT4'Hi7GHTINTHQVALS.' CONIREM. Pc Q 4000 PSI @ 28 DAYS W/.0.50 WATERACEMENT RATIO. GROUTING SHOULD BE PERFORMED AS SOONAS P WISLE REINFORCING STEEL: ASNA-6I5GRADE 60, AFTER THE CONCRL•7FMASONRYUNITSAREPLACED, CONOWTEMASONRY UNITS: ASTMC90 MORTAR: USE OBP TYPE S PER A57N C270 9. PROWDEODNIROL JUINTSAT 40'01C MAX. GROUT.'. USE 2000 PSI 018 CA PER ASTM C 476, CEMENT.- POR TIANDCEMENT' PER ASTM C-150TYPE Q/V. 10. BUILDINGDEPAR7MLMINSPEC770NSHALL BEOFTHE FOLLOWINGSIEPS: l$t fVUND4770N TRENCH WITH SECURED REINFURCING STEEL GENERAL NOTES: 2nd. BLOa( WALL WITH REINFORCING STEEL BEFOREGROUT. 3N. MID -HEIGHT GROUTING FOR WALLS OVER 4' HIGH. 1. ALL MATERIALS, PRODUCTS, WOR04ENSHIP, TETTING AND 4Lh. GROUTED WALL AND DRAINAGE SYSTEM. INSPECTION SHALLCOMPLY WITHTHE2013CBG 5th BALLANDEIS• ' 2. ALL FOOTINGS SHALL BE POURED ON UNDLSTURBED'NATURAL 11.OAUT HEAD "MSAT FIRST COLIRSEAT EVERY32' 0/C WITH. GROUND OR ON UNDISTURBED ENGINEERED FILL 1 Lau. FT. OF p/ 'GA4VE1 FOR WEEPHOLEWHEN THE WALL IS LESS THAN AGA 3. WALL SHALL BE LAID TRUEOLIDD PLUMB, L AND ALL CELS SHAM BE GROUTED SOLID.. 12 PROVIDE 4'e SnR 35 PERFORATED PIPE WITH PBUV947TONS DOWNAT 196 MIN. SLOPE WITH 1 CF. OF3/4' GRAVEL 4. ALL SAUCES SHALL BE 48 BAR DIAMETERS. WRAPPED WITH KRAFT 14ON RVER FABRIC OR EQUAL Li4CTC DRAINAGESYSTEM SHALL HAVE 7EEC ONNEMONAND NON - S. ALL VERTICAL AND HORLZONTAL LIARS SHALL BE77ED PERFORATED 2'B OUTLET PIPEAT EVERYIO' O/C7HROUGH 70GETHEX THE WALL AT 2 % SLOPEABOVE THE FINISHED SURFACE: 6. LTO NOT USEHFAVYCOMPACIONEQUIP14ENTAQL4CENTTO _ THE WALL THE mvTRACIURSHALL BERESPbIVSIBLEAOR ANY DAMAGES 70 THE WAIL RESUL77NG FROM INAPPROPRIATE COMPAC17ON 7ECNVIQUESAND EQUIPMEMS. 7. THE RETAINING WALLS SHALL NOT BE 44CWLLED UNTIL AT LEAST 14 n4 VS - UNLESS PROPER SHORING IS PROVIDED CONMOIL JOINT &OCX WALL W1 REINFORCING PFR DETAIL£ I4HORZCUM 0TVPASREi2L,fMM- PROVME24'NM LAPAND M4fNTAIN3' CLEAR FROM SOIL v o b v. • p p ' /4 HORZ COMr. 0 BOTTOM - PROVIDE 24 NIA! LAP AND MAINTAIN3'CLE7RfRON SOIL NATURAL SOB. OR CONPACTEURLL' Q•:FaF` L �Nq . FOOTING STEP DETAIL C31925 .. Exp. 12-31-2014 F OF 0- C P!. Use menu Item Settings > Printing & Title Block to set these five lines of Information for your program. This Wall In File: c:\users\tmallis\documents\retainpro l0 RetalnPrp 10.;(c)1987-2014; Build 10:14.8.13 Fl6erisa : Y.. -OA Al Irnricn- n RIY.V`K CnMDAAtV IWC Criteria 2,044 psf OK Retained Height = 2.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00 : 1 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge -Loads 2,044 psf OK Surcharge Over Heel = 0,0 psf Used To Resist Sliding & Overturning 2,500 psf Surcharge Over Toe = .0.0 psf Used for Sliding & Overturning ACI Factored @ Heel = LAxial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary Lateral Sliding Force = Wall Stability Ratios less 100% Passive Force= - Overturning = 1.67 OK Sliding - 1.92 OK Total Bearing Load = 1.,,247 lbs ...resultant ecc. = 1�0.12'in Title 2'0" retain w 6' wall 110 85c wind Page: Job # ' ...New... Dsgnr: Date: 18 SEP•2014 Description.... tr 36537 signature Cantilevered Retaining Wall Design Soil Pressure @ Toe = 2,044 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,453 psf ACI Factored @ Heel = 0-psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 5.9 psi Ok Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 276.0 lbs less 100% Passive Force= - 93.8 lbs less 100% Friction Force = - 436.3 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5: 1 Stability = 0.0 lbs OK Soil Data Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00. pcf FootingilSoil Friction = 0.350 Soil height to ignore at Back of Wall = for passive pressure = 12.00 In Lateral Load Applied to Stem . Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0:00 ft The above lateral load Wall to Ftg CL Dist = has been Increased 1.00 by a factor of Base Above/Below Soil Wind on Exposed Stem = 16.0 psf ;ode: CBC 2013,AC1 318-11,AC1 530-11 ate. Adjacent Footing. Load Stem Adjacent Footing Load = 0:0jus Footing Width = 0.00 ft Eccentricity - 0.00 in Wall to Ftg CL Dist = 0.0d ft Footing Type Line Load Base Above/Below Soil Masonry at Back of Wall = 0.0 ft Polsson's Ratio = 0.300 Stem Construction Top Stem 2nd CBC 2013,ACI Dead Load Stem OK Stem OK Design Height Above Ftg ft= 2.00 0.00 Wall Material Above "Ht" = Masonry Masonry Thickness = 6.00 8.00 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 32.00 Rebar Placed at = Center Edge Design Data fb/FB + fa/Fa = 0.575 0.545 Total Force @ Section lbs = 96.0 176.0 Moment.... Actual ft-#= 288.0 533.3 Moment..... Allowable ft-#= 501.0 979.3 Shear..... Actual psi = 2.9 2.8 Shear..... Allowable psi = 45.7 45.4 Wall Weight psf = 47.0 84.0 Rebar Depth 'd' in = 2.75 5.25 LAP SPLICE IF ABOVE In = 24.00 24.00 LAP SPLICE IF BELOW n= 24.00 HOOK EMBED INTO FTG In = 6.00 Hook embedment reduced by stress ratio Masonry Data - fm psi = 1,500 1,500 Fs psi = 32,000 32,000 Solid Grouting = No Yes Load Factors = 21.48 21.48 = 1.000 1.000 Building Code CBC 2013,ACI Dead Load 1.400 Live Load 1.700 Earth, H 2.200 Wind, W 1.300 Seismic, E 1.000 Modular Ratio 'n' Short Term Factor = 21.48 21.48 = 1.000 1.000 , Equiv. Solid Thick. in = 3.90 7.60 Masonry Block Type =Normal Weight l• t�`,r e � �,,;':•� Masonry Design Method = ASD Concrete Data fc psi = . i n\ >♦„j�'Y Y psi = �r'Z4,,. s.;y Use menu Item Settings > Printing & Title Block to set these five lines of information for your program. This Wall in File: a:lusersFtmallisldocumentsU Title 2'0" retain w 6' wall 110 85c wind Page: Job #...New... Dsgnr: Date: 18 SEP 2014 Description.... pga west tr 36537. signature Icens6., Kwoo ggapps Cantilevered Retaining Wall Design icense To .Qg BLOCK: COMPANY; INC. Footing Dimensions & Strengths Footing Design Results ,ode: CBC 2013,AC1 318-11,AC1 530-11 Toe Width = 0.00 ft Toe Heel Heel Width = 2.50. _ Factored Pressure = 2,453 0 psf Total Footing Width = 2.50 Mu': Upward = 0 12.5 ft-# Footing Thickness = 12.00 in Mu': Downward = 0 1,064 ft-# Mu: Design = 0 939 ft-# Key Width = 0.00 in Actual 1 -Way Shear = 0.00 5.86 psi Key Depth = 0.00 Allow 1 -Way Shear = 0.00 75.00 psi Key Distance from Toe ft = 2.75 ft Toe Reinforcing = None Spec'd fe = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm. 3.00 In Toe: Not req'd; Mu < S' Fr Heel: Not req'd, Mu < S ` Fr Key: No key defined Summary,of Overturning: & Res sting Forces & Moments .::..OVERTURNING:.... _ .....RESISTING..... Force Distance 'Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 180.0 1.00 180.0 Soil Over Heel = 421.7 1.58 667.6 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = Load @ Stem Above Soil = 96.0 6.00 576.0 ` Axial Live Load on Stem = = Soil Over Toe = Total 276.0 O.T.M. 756.0 Resisting/Overturning Ratio Vertical Loads used for Soil Pressure = = 1.67 1,246.7 lbs Surcharge Over Toe Stem Weight(s) = 450.0 0.28 126.5 Earth @ Stem Transitions= Footing Weight = , 375.0 1.25 468.8 Key Weight = 2.75 Vert. Component = Total = 1,246.7 lbs R.M.= 1,262.9 Axial live load NOT included in total displayed or used for overturning resistance, but is Included for soil pressure calculation. k Use menu item Settings > Printing & Title Block . Title 2'8" retain w 6' wall 110 85c wind Page: to set these five lines of Information Job # ...New... Dsgnr: Date: 18 SEP 2014 for your program. Description.... This Wall in File: c:\users\tmallis\documents\retainpro 10 project files\pga west tr 36537 signature RetalnPw 10 (c)1987.2014, Build 10.14.8.13 License: KKW-0@05q4 1 - Cantilevered Retaining Wall Design ;ode: CBC 2013,AC1 318-11,AC1 530-11 License To : ORC� BLOCK COMPANY, INC. Criteria • 1,938 psf OK Retained Height = 2.67 It Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads 1,938 psf OK Surcharge Over Heel = 0,0 psf Used To Reslst Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 2,326 psf Axial_ Load Applied to Stem _ Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary Sliding Calcs (Vertical Component NOT Used) Wall Stability Ratios 365.4 lbs Overturning = 1.86 OK Sliding = 1.75 OK Total Bearing Load = 1,558 lbs ...resultant ecc. _ 10.07 in Soil Pressure @ Toe = 1,938 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf. Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,326 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 6.1 psi OK Allowable • = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 365.4 lbs less 100% Passive Force = - 93.81 ' bs less 100% Friction Force = - 545.5 ls Added Force Req'd =. 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Soil Data- Allow ata Allow Soil Bearing 2,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.350 Soil height to ignore at Back of Wall - for passive pressure = 12.00 in Lateral Load Applied to •Stern Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft The above lateral load = has been increased 1.00 by a factor of _ Wind on Exposed Stem = 16.0 psf Stem Construction _ Design Height Above Ftg ft= Wall Material Above "Ht" _ Thickness = Rebar Size = Rebar Spacing = Rebar Placed at _ Design Data at Back of Wall - 0.0 ft fb/FB 4- fa/Fa = Total Force @ Section lbs = Moment.... Actual ft-#= Moment..... Allowable ft-#= Shear..... Actual psi = Shear..... Allowable psi = Wall Weight psf = Rebar Depth 'd' in= LAP SPLICE IF ABOVE in = LAP SPLICE IF BELOW in = HOOK EMBED INTO FTG in = Load Factors Stem OK Building Code CBC 2013,ACI Dead Load 1.400 Live load 1.700 Earth, H 2.200 Wind, W 1.300 Seismic, E 1.000 Masonry Data I'm Fs Solid Grouting Adjat:ent Footing Load Stem OK Adjacerit Footihq Load = 0A itis Footing Width - 0.00 ft Eccentricity - 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil Edge at Back of Wall - 0.0 ft Poisson's Ratio = 0.300 Stem 2nd Stem OK Stem OK 2.67 0.00 Masonry Masonry 6.00 8.00 # 4 # 4 32.00 32.00 Center Edge 0.575 0.885 96.0 238.6 288.0 671.2 501.0 979.3 2.9 3.8 45.7 45.7 47.0 84.0 2.75 5.25 24.00 24.00 24.00 6.00 Hook embedment reduced by stress ratio Modular Ratio 'n' Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy psi= 1,500 1,500 psi = 32,000 32,000 = No Yes = 21.48 21.48 = 1.000 1.000 in= 3.90 7.60 = Normal Weight = ASD psi:= psi •i. •^-, ifs-`'�• Use menu Item Settings > Printing & Title Block Title 2'81 retain w 6' wall 110 85c wind Page: to set these.five lines of Information Job # ...New... Dsgnr: Date: 18 SEP 2014 .for your program. Description.... This Wall in File: c:\users\tmallis\documents\retainpro 10. project, files\pga west tr 36537 signature RetalnPro,10 (c)1987-2014, Build 10.14.8.13 LIcense : KKw-0605g4p1 t Cantilevered Retaining Wall Design %ode: CBC 2013,AC1 318-11,ACI 530-11 License To : ORCO BLOCK COMPANY, INC. Footing_Dimensions & Strengths Toe Width = OAO ft Heel Width = 2.75 . .Total Footing Width = 2.75 Footing Thickness = 12.00 In Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 2.75.ft fc = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 • @ Btm. 3.00 In Summaev.of .'reel Active Pressure = Surcharge over Heel = I" Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = ng. � Resistin( ..':..OVERTURN Force Distanc lbs • ft 269.4 1.22 96.0 6.67 Footng:Deslgn Results 639.7 Toe Heel Factored Pressure = 2,326 0 psi Mu': Upward = 0 328 ft-# Mu': Downward = 0 1,620 ft-# Mu: Design = 0 1,292 ft-# Actual 1 -Way Shear = 0.00 6.07 psi Allow 1 -Way Shear = 0.00 75.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S ' Fr Heel: Not req'd, Mu < S ' Fr Key: No key defined )ices •&,Moments Stem Weight(s) = 506.3 ft-# 329.5 640.3 Total 365.4 O.T.M. 969.9 Res istinglOverturning Ratio = 1.86 Vertical Loads used for Soil Pressure = 1,558.5 lbs 0 ......RESISTING..... Force Distance Moment lbs ft ft-# Soil Over Heel = 639.7 1.71 1,092.8 Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = " Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 506.3 0.29 145.3 Earth @ Stem Transitions= Footing Weighi = 412.5 1.38- 567.2 Key Weight = 2.75 Vert. Component = Total = 1,558.5 lbs R.M.= 1,805.2. Axial live load NOT included in total displayed or used for overturning resistance, but Is Included for soil pressure calculation. 1:z. r�q'l�►,�' . 1'.�':i .ice '�, t: �Ji"y�r•'f.�' �.j� Use menu item Settings > Printing & Title Block Title 3'4" retain w 6' wall 110 85c wind Page: to set these five lines of information Job # ...New... 'Dsgnr: Date: 18 SEP 2014 for your program. Description.... This Wallin File: c:\users\tmallis\documents\retainpro 10 project files\pga west tr 36537 sense 't.o.: Criteria Retained Height Wall height above soil Slope Behind Wall Height of Soil over Toe Water height over heel 4:8:13 PANY; INC. Cantilevered Retaining Wall Design 'ode: CBC 2013,AC1 318-11,AC1 530-11 Surcharge Loads LSoil Data Surcharge Over Heel = = 3.33 ft Allow Soil Bearing = 2,500.0 psf = 6.00 ft Equivalent Fluid Pressure Method 2,357 psf Heel Active Pressure - 40.0 psf/ft = 0.00: 1 Axial Live Load = = = 6.00 In Passive Pressure = 150.0 psf/ft = 0.0 ft Soil Density, Heel = 115.00 pcf Overturning = Soil Density, Toe = 115.00 pcf 1.61 OK FootingliSoil Friction = 0.350 ....for 1.5 : 1 Stability = Soil height to ignore Rebar Placed at = for passive pressure = 12.00 in Surcharge Loads 1,964 psf OK Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 2,357 psf Axial Load Applied to.Stem Axial Dead Load - 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Desi n Summary Sliding Calcs (Vertical Component NOT Used) Wall Statiillty Ratios 471.0 lbs Overturning = 1.99 OK Sliding = 1.61 OK Total Bearing Load 1,905 lbs ...resultant ecc. = 10,24 in Soil Pressure @ Toe = 1,964 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf ' Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,357 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 6.6 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 471.0 lbs less 100% Passive Force = - 93.8 lbs less 100% Friction Force = - 666.8 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Load Factors Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ..,Height to Bottom = 0.00 ft The above lateral load Wall to Ftg CL Dist = has been Increased 1.00 by a factor of Base Above/Below Soil Wind on Exposed Stem = 16.0 psf Adjacent Footing Load Top Adjageni Footingload. = 0.01bs= Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil = = at Back of Wall 0.0 ft Poisson's Ratio 0.300 Stem Construction Top Stem 2nd _ _ 1.700 Stem OK Stem OK Design Height Above Ftg ft= 3.33 0.00 Wall Material Above "Ht" = Masonry Masonry Thickness - 6.00 8.00 Rebar Size # 4 # 4 Rebar Spacing = 32.00 32.00 Rebar Placed at = Center Edge Design Data fb/FB + fa/Fa = 0.575 0.872 Total Force @ Section lbs = 96.0 317.8 Moment.... Actual ft-#= 288.0 .853.9 Moment..... Allowable ft-#= 501.0 979.3 Shear..... Actual psi = 2.9 5.0 Shear.`.... Allowable psi = 45.7 46.0 Wall Weight psf= 47.0. 84.0 Rebar Depth 'd' In= 2.75 5.25 LAP SPLICE IF ABOVE In= 24.00 36.00 LAP SPLICE IF BELOW In= 24.00 HOOK EMBED INTO FTG In = 7.32 Hook embedment reduced by stress ratio Masonry Data fm psi= 1,500 1,500 Fs psi = 32,000 32,000 Solid Grouting No Yes Building Code CBC 2013,ACI Dead Load 1.400 Live Load 1.700 Earth, H 2.200 Wind, W 1.300 Seismic, E 1.000 Modular Ratio'n' Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy 21.48 21.48 1.000 1.000 In= 3.90 7.60 = Normal Weight = ASD psi = psl! Use menu Item Settings > Printing & Title Block to set these five linet; of Information for your program. Title 3'4" retain w 6' wall 110 85c wind Page: Job # ...New... Dsgnr: Date: ' 18 SEP 2014 Description.... This Wall in File: c:\users\tmallis\documents\retaInpro 10 project:files\pga west tr 36537.s16nature Rdteih,P•tO 10 (c)1987-2014; Build 1;0148:13 893.6 1.83 Iceiise o�9s9agq1.' License BLOCK Cantilevered Retaining Wall Design :ode: CBC 2013,AC1 318-11,AC1 530-11 T o :. RCO COMPANY, INC. Surcharge Over Heel = ..bp6 tg Dimensions & Strengths Footingpesign Results Toe Width Toe Heel Heel Width 3.00 Factored Pressure = 2,357 0 psf Total Footing Width -3.00 Mu': Upward = 0 605 ft-# Footing Thickness = 12.00 in Mu': Downward = 0 2,332 ft-# Key Width - 0.00 In Mu: Design = 0 1,727 ft-# Key Depth = 0.00 in Actual 1 -Way Shear = 0.00 6.63 psi Key Distance from Toe = 2.75 ft Allow 1 -Way Shear = 0.00 75.00 psi 561.7 Toe Reinforcing = None Spec'd 163.7 fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd 450.0 Min. As % . = 0.0018 Other Acceptable Sizes & Spacings Key Weight = Cover @ Top . 2.00 @ Btm: 3.00 in 2.75 Vert. Component = Toe: Not req'd, Mu < S " Fr Heel: Not req'd, Mu <S " Fr 1,905.3 lbs r Key: No key defined of Overturr Item Heel Active Pressure = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = Force Distance. lbs ft 375.0 1.44 96.0 7.33 Moment ft-# 541.2 703.7 Total 471.0 O.T.M. 1,244.9 .Resisting/Overturning Ratio = 1.99 Vertical Loads used for Soil Pressure = 1,905.3 . lbs Force �v15.Psfance Moment 'Ibs ft ft-# Soil Over Heel = 893.6 1.83 1,638.2 Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Welght(s) = 561.7 0.29 163.7 Earth @ Stem Transitions= Footing Weight = 450.0 1.50 675.0 Key Weight = 2.75 Vert. Component = Total c 1,905.3 lbs R.M.= 2,476.9 Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation. Use menu item Settings > Printing & Title Block to set these five lines of Information for your program. Title 4'0" retain w 6' wall 110 85c wind Page: Job # ...New... Dsgnr: Date: 18 SEP 2014 Description.... This Wall in File: c:\users\tmalIis\documents\retainpro 10 project'fileslpga west tr 36537 44lcense: KKW Mo 9411 Cantilevered Retaining Wall Design :ode: CBC 2013,ACI 318-11,ACI 530-11 4lcense To :N .-BLOCK COMPANY. INC. Criteria 1,993 psf OK - Retained Height = 4.00 ft Wall height above soil = 6.00 It Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 In Water height over heel = 0.0 It Surcharge Loads 1,993 psf OK - Surcharge Over Heel = 0.0 psf Used Td -Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf . Used for Sliding & Overturning 2,391 psf Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in �_ Design Summary Sliding Calcs (Vertical Component NOT Used) Wall Stability Ratios 596.0 lbs Overturning = 2.15 OK Sliding = 1.67 OK Total Bearing Load = 2,344 lbs ...resultant ecc. = 10.09 in Soll Pressure @ Toe = 1,993 psf OK - Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,391 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 6.7 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 596.0 lbs less 100% Passive Force= - 177.1 lbs less 100% Friction Force = - 820.3 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5: 1 Stability = 0.0 lbs OK Load Factors = 2,500.0 psf Building Code CBC 2013,ACI Dead Load 1.400 Live Load 1.700 Earth, H 2.200 Wind, W 1.300 Seismic, E 1.000 Soil Data Allow Soll Bearing . = 2,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingllSoll Friction = 0.350 Soil height to ignore = at Back of Wall for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Helght'to Bottom = 0.00 ft The above lateral load Wall to Ftg CL Dist = has been Increased 1.00 by a factor of Base Above/Below Soil Wind on Exposed Stem = 16.0 psf Adjacent Footing Load Top Stem Adfapppi Footing Load. = 0.0" bs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type . Line Load Base Above/Below Soil = at Back of Wall 0.0 ft Poisson's Ratio = 0.300 Stem Construction Top Stem 2nd - Stem OK Stem OK Design Height Above Ftg ft= 4.00 0.00 Wall Material Above "Hf' = Masonry Masonry ' Thickness = 6.00 8.00 Rebar Size = # 4 # 4 Rebar Spacing 32.00 16.00 Rebar Placed at = Center Edge Design Data fb/FB + fa/Fa = 0.575 0.575 Total Force @ Section lbs = 96.0 416.0 Moment.... Actual ft-#= 288.0 1,098.7 Moment..... Allowable ft-# = 501.0 1,909.1 Shear..... Actual psi = 2.9 6.6 Shear..... Allowable psi = 45.7 46.2 Wall Weight psf= 47.0 84.0 Rebar Depth 'd' In= 2.75 5.25 LAP SPLICE IF ABOVE in = 24.00 24.00 LAP SPLICE IF BELOW in= 24.00 HOOK EMBED INTO FTG in = 6.00 embedment reduced by stress ratio Masonry Data .Hook fm psi= 1,500 1,500 Fs psi = 32;000 32,000 Solid Grouting = No Yes Modular Ratio 'n' = 21.48 21.48 Short Term Factor = 1.000 1.000 Equiv. Solid Thick. In= 3.90 7.60 Masonry Block Type = Normal Weight Masonry Design Method = ASD Concrete Data fc psi = Fy psi - 0'#J vit Use menu Item Settings > Printing & Title Block Title 4'0" retain w 6' wall 110 85c wind Page: to set these five lines of information Job # ...New... Dsgnr: Date: 18 SEP 2014 for your program. Description.... This Wall In. File: c lusers\tmallisltlocuments retalnpr 1:0' project:fileslpga•west tr 36537 signature RatalinPro:10.(c):7 88.7=2014,;.Bulld :10.14;8:13 License :Cw-o��4ot License' o : ,•_, ._O.�BLOCK COMPANY.,: INC. Cantilevered Retaining Wall Design :ode: CBC 2013,ACI 318-11,ACI 530-11 ;Footing; Dimensions &;StrengtFis _ Footing.Dd'l& Results Item lbs Toe Width = 0.00 ft Toe Heel Heel Width = 3.25 Factored Pressure = 2,391 0 psf _ Total Footing Width = 3.25 Mu': Upward = 0 1,077 ft-# Footing Thickness = 12.00 in Mu': Downward = 0 3,229 ft-# Mu: Design = 0 2,152 ft -4 Key Width = 12.00 In Actual 1 -Way Shear = 0.00 6.68 psi Key Depth = 4.00 in Allow. 1 -Way Shear = 0.00 75.00 psi Key Distance from Toe = 2.25 ft Toe Reinforcing = None Spec'd 1,601.3. fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Vertical Loads used for Soil Pressure = Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm. 3.00. in Toe: Not req'd, Mu < S " Fr Stem Welght(s) = 618.0 Heel: Not req'd, Mu < S ' Fr 182.5 Earth @ Stem Transitions= Key: Not Req'd = Mu<S"Fr I Summarv.of Overturnina.8 Resistina forces $ Moments I ....OVERTURNING..... . Force . Distance Moment , Item lbs ft ft-# Heel Active Pressure - 500.0 1.67 833.3 Surcharge over Heel 2,327.2 Sloped Soil Over Heel = Surcharge Over Toe =. Adjacent Footing Load = Added Lateral Load = Adjacent Footing Load = Load @ Stem Above Soil = 96.0 8.00 768.0 Total 596.0 O.T.M., 1,601.3. Resisting/Overturning Ratio _ •2.15 Vertical Loads used for Soil Pressure = 2.343.8 lbs 3 Force Distance Moment lbs ft ft-# Soil Over Heel = 1,188.3 1.96 2,327.2 Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Welght(s) = 618.0 0.30 182.5 Earth @ Stem Transitions= Footing Weight = 487.5 1.63 792.2 Key Weight = 50.0 2.75 137.5 Vert. Component = Total = 2,343.8 lbs R.M.= 3,439.3 • Axial live load NOT Included In total displayed or used for resistance, but is included for soil pressure calculation. overturning Use menu item Settings > Printing & Title Block to set these five lines of Information for your program. This Wall in File: c:\users\tmallisldocumentslretainpro 10 project Criteria 2,112 psf OK Retained Height = 4.67 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads 2,112 psf OK Surcharge :Over Hedy - 0 O:pst Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 2,534 psf Axial Load Applied to,Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 In Design StAmr ary Sliding Calcs (Vertical Component NOT Used) Wall StabllltyRatios - Overturning = 2.21 OK Sliding = 1.63 OK Total Bearing Load 2,796 lbs ...resultant ecc. = 10.41 In Title 4'8'; retain w 6' wall 110 85c wind Page: Job # ...New... Dsgnr: Date: 18 SEP 2014 Description.... west tr. 36537 signature Cantilevered Retaining Wall Design Soil Pressure @ Toe = 2,112 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf. Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,534 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear.@ Heel = 7.4 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 739.0 lbs less 100% Passive Force = - 225.0 lbs less 100% Friction Force = - 978.6 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Soil Data - Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoll Friction = 0.350 Soil height to ignore at Back of Wall - for passive pressure = 12.00 In Lateral Load Applied to Stem . Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom . = 0.00 ft The above lateral load Wall to Fig CL Dist - has been Increased 1.00 by a factor of Base Above/Below Soil Wind on Exposed Stem = 16.0 psf ;ode: CBC 2013,ACI 318-11,AC1 530-11 Adjacent. Footing Load Top Stem Atljac6.nt FobtingLoad _ :0A. lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Fig CL Dist - 0.00 ft Footing Type Line Load Base Above/Below Soil 6.00 at Back of Wall - 0.0 ft Poisson's Ratio = 0.300 Stem Construction Top Stem 2nd Design Height Above Ftg ft = Stem OK 4.67 Stem OK 0.00 Wall Material Above "Ht" = Masonry Masonry Thickness - 6.00 8.00 Rebar Size _ # 4 # 4 Rebar Spacing = 32.00 16.00 Rebar Placed at = Center Edge Design Data psf = _- '�,� • i Seismic, E fb/FB + fa/Fa = 0.575 0.741 Total Force @ Section lbs = 96.0 532.2 Moment.... Actual ft-#= 288.0 1,415.3 Moment..... Allowable ft-#= 501.0 1,909.1 Shear..... Actual ' psi = 2.9 8.4 Shear..... Allowable psi = 45.7 46.5 Wall Weight psf = 47.0 84.0 Rebar Depth 'd' in= 2.75 5.25 LAP SPLICE IF ABOVE in= 24.00 24.00 LAP SPLICE IF BELOW In= 24.00 HOOK EMBED INTO FTG in = 6.23' Hook embedment reduced by stress ratio Masonry Data fm psi= 1,500 1,500 Fs psi = 32,000 32,000 Solid Grouting No Yes Load Factors Modular Ratio'n' = 21.48 21.48 Building Code CBC 2013,ACI Short Term Factor = 1.000 1.000 � ^�,:.:•••-•�. ; -r,;.� �!-�^• �� .-�-.. ; r,•• ��.. Dead Load 1.400 Equiv. Solid Thick. in = 3.90 7.60 �7�,� 1 Live Load 1.700 Mason Block Type Masonry Yp = Normal Weight 9 Mfr:.`; Earth, H 2.200 Masonry Design Method = ASD �/ �" :=• " Wind, W 1.300 Concrete Data psf = _- '�,� • i Seismic, E 1.000 F Fy psi;= .{� y �,� ,, •;� � T� .�.. �.,� r •`.i.�/ 1mi�� Use menu Item Settings > Printing & Title Block to set these five Iines of Information dor your program. This Wall in File: c:\users\tmaIlis\documents\retainpro 10 project files\pc Title 6'0" retain w 6' wall 110 65c wind Page: Job # ...New... Dsgnr: Date: 18 SEP 2014 Description.... west tr 36537 signature RotainPro 10 (cj;1987-2014, 13u110T014;8A3 cense: Kw oggos94001 Cantilevered Retaining Wall Design %ode: CBC 2013,ACI 318-11,AC1 530-11 Licem To : ORCO BLOCK C.OM�PANY; INC. _ Retained Height = 6.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00 : 1 Height of Soil over Toe = 6.00 In Water height over heel = 0.0 ft Surcharge Loads 2,220 psf OK Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Oyerturnirig ACI Factored @ Toe = Axial Load Applied- to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0:0 in '.pesign Summary 75.0 psi Wall Stability Ratios NOT Used) Overturning = 2.51 OK Sliding 1.62 OK Total Bearing Load 4,042 lbs ...resultant ecc. = 10.93 in - Soil Pressure @ Toe = 2,220 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = psf. Soil Pressuro Less Than '00 Allowable ACI Factored @ Toe = 2,664 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 11.1 psi OK Allowable I. = 75.0 psi Sliding Caics (Vertical Component NOT Used) Lateral Sliding Force = 1,076.0 lbs less 100% Passive Force = - 333.3 lbs less 100% Friction Force = - 1,414.8 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5: 1 Stability = 0.0 lbs OK Load Factors Lateral Load = Building Code CBC 2013,ACI Dead Load 1.400 Live Load 1.700 Earth, H 2.200 Wind, W 1.300 Seismic, E 1.000 Soil Data, Lateral Load = Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIISoil Friction = 0.350 Soil height to ignore Poisson's Ratio = for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom . = 0.00 ft The above lateral load Wall to Ftg CL Dist = has been Increased 1.00 by a factor of Base Above/Below Soil = Wind on Exposed Stem = 16.0 psf Adjacent Footing. Load Top Stem AdJacent.Footih§-,L.oad ' _ OZIbs Footing Width - 0.00 ft Eccentricity 0.00 In Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil = 0.0 ft at Back of Wall = Poisson's Ratio = 0.300 Stem Construction Top Stem 2nd 3rd Stem OK Stem OK Stem OK Design Height Above Ftp ft = 6.00 2.00 0.00 Wall Material Above "Ht" = Masonry Masonry Masonry Thickness - 6.00 8.00 12.00 Rebar Size = # 4 # 4 # 4 Rebar Spacing _ 32.00 16.00 16.00 Rebar Placed at = Center Edge Edge Design Data fb/FB + fa/Fa = 0.575 0.575 0.690 Total Force @ Section lbs = 96.0 416.0 816.0 Moment.... Actual ft-#= 288.0 1,098.7 2,304.0 - Moment ..... Allowable ft-#= 501.0 1,909.1 3,340.5 Shear..... Actual psi = 2.9 6.6 7.6 Shear..... Allowable psi = 45.7 46.2 46.2 Wall Weight psf = 47.0 84.0. 133.0 Rebar Depth 'd' In= 2.75 5.25 9.00 LAP SPLICE IF ABOVE in = 24.00 24.00 24.00 LAP SPLICE IF BELOW in = 24.00 24.00 HOOK EMBED INTO FTG in = 6.00 Hook embedment reduced by stress ratio Masonry Data fm psi'= 1,500 1,500 1,500 Fs psi = 32,000 32,000 32,000 Solid Grouting = No Yes Yes Modular Ratio 'n' = 21.48 21.48 21.48 - r� Short Term Factor = 1.000 1.000 1.000 �� Equiv. Solid Thick. In= 3.90 - 7.60 11.60 , r _ ✓ �� Masonry Block Type = Normal Weight��� Masonry Design Method = ASD Concrete Data fc Fy psi = psi_ '_ i r\h.. u .;,`, a Use, menu Item Settipgs> Printing &,Title Block to set these. five lines of Information Tor your program. Title 6'0'; retain w 6' wall 110 85c wind Page: Job # ...New... Dsgnr: Date: 18 SEP 2014 Description.... This Wall In File:. c:\users\tmallis\documents\retaInpro.10 project.files\pga west tr 36537 -signature RetafnPro 10 (c),:1987 2014; .Build :1014:8 13 Lrcense; Kw o66oeggap1 Cantilevered Retaining Wall Design %ode: CBC 2013,AC1 318-11,ACI 530-11 license To ORCO BLOCK COMPANY; INC. ummary of Overtu Item Heel Active Pressure = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = rning & Resisting. .....OVERTURNII Force' Distance lbs ft 980.0 2.33 96.0 10.00 Footin Desi n Results - 9• g- . --- .....R Force Distance Footing Dimensions & Strengths ; Toe Width = 0.00 ft Heel Width = 4.25.. Total Footing Width = 4.25 Footing Thickness = 12:00 in Key Width 12.00 in Key Depth = 10.00 in Key Distance from Toe = 3.25 ft fc = 2,500 psi . Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % _= 0.0018 Cover @ Top 2.00 @. Btm: 3.00 In ummary of Overtu Item Heel Active Pressure = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = rning & Resisting. .....OVERTURNII Force' Distance lbs ft 980.0 2.33 96.0 10.00 Footin Desi n Results - 9• g- . --- .....R Force Distance Toe Heel Factored Pressure = 2,664 0 psf Mu': Upward = 0 2,948 ft-# Mu': Downward = 0 7,203 ft-# Mu: Design = 0 4,255 ft-# Actual 1 -Way Shear = 0.00 11.14 psi Allow 1 -Way Shear = 0.00 75.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Adjacent Footing Load = Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Axial Dead Load on Stem = Toe: Not req'd, Mu < S • Fr Heel: #4@ 9.26 In, #5@ 14.35 in, #6@ 20.37 In, #7@ 27.78 in, #8@ 36.57 in, #9@ 46 Key: #4@ 9.51 in, #5@ 14.60 in, #6@ 20.62 In, #7@ 28.03 in, Forces & Moments Soil Over Toe = ft-# 2,286.7 960.0 Total 1,076.0 O.T.M. 3,246.7 Resisting/Overturning Ratio = 2.51 Vertical Loads used for Soil Pressure = 4,042.3 lbs .....R Force Distance Moment lbs ft ft-# Soil Over Heel = 2,242.5 2.63 5,886.6 Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 884.0 0.36 315.5 Earth @ Stem Transitions= 153.3 0.83 127.8 Footing Welghl = 637.5 2.13 1,354.7 Key Weight = 125.0 3.75 468.8 Vert. Component = Total = 4,042.3 lbs R.M.c 8,153.3 • Axial live load NOT included in total displayed or used for resistance, but Is included for soil pressure calculation. overturning FINANCIAL • /• DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - EA ADDITIONAL 50 LF 101-0000-42404 0 $76.86 $0.00 PAID BY METHOD RECEIPT # • CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION - ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $60.91 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for FENCE OR FREESTANDING WALL $185.63 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RET WALL <=12 - EA ADD 50 LF 101-0000-42404 0 $29.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RET WALL <=12 - FIRST 100 LF 101-0000-42404 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RET WALL <=12 - FIRST 100 LF PC 101-0000-42600 0 $60.91 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for RETAINING WALL $137.77 $0.00 40 $0.00 Description: 166 LF OF COMBO WALL CHRONOLOGY Type: WALL/FENCE Subtype: Status: APPROVED Applied: 1/12/2015 SKH Approved: 1/28/2015 SKH Parcel No: 775370016 Site Address: 80073 CHAMPIONS WAY LA QUINTA,CA 92253 Subdivision: TR 29421 Block: Lot: 37 Issued: Lot Scl Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $10,375.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 166 LF OF COMBO WALL PER APPROVED DETAIL. 2013 CALIFORNIA BUILDING CODES. • • Printed: Wednesday, January 28, 2015 10:28:55 AM 1 of 3 CR CY.fTFMt CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES _ E-MAIL STEPHANIE KHATAMI 1/12/2015 1/12/2015 PLAN CHECK SUBMITTAL RECEIVED STEPHANIE KHATAMI 1/8/2015 1/8/2015 • • CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT ULRICH SAUERBREY 74948 LIVE OAK STREET INDIAN WELLS CA 92210 ulrichs@uslandlink.co m CONTRACTOR CALIFORNIA WEST CONSTRUCTION 1 5927 PRIESTLY DRIVE STE 110 CARLSBAD CA 92008 OWNER LQR GOLF 1 BUSH ST STE 1100 SAN FRANCISCO I CA 1 0 Printed: Wednesday, January 28, 2015 10:28:55 AM 1 of 3 CR CY.fTFMt Printed: Wednesday, January 28, 2015 10:28:55 AM 2 of 3 CR SVC7FM.S FINANCIAL • • REMARKS, NOTES CI:TY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY YY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid forBU1LDING STANDARDS ADMINISTRATION $1.00 $0.00 0 BSA: WALL/FENCE - EA 101-0000-42404 0 $76.86 $0.00 FOOTINGS AOR ADDITIONAL 50 LF WALL/FENCE - FIRST 101-0000-42404 0 $47.86 $0.00 100 LF WALL /FENCE - FIRST 101-0000-42600 0 $60.91 $0.00 100 LF PC Total Paid for FENCE OR FREESTANDING WALL $185.63 $0.00 RET WALL <=12 - EA 101-0000-42404 0 $29.00 $0.00 ADD 50 LF RET WALL <=12.- FIRST 101-0000-42404 0 $47.86 $0.00 100 LF RET WALL <=12 - FIRST 101-0000-42600 0 $60.91 $0.00 100 LF PC Total Paid for RETAINING WALL $137.77 $0.00 TOTALS:4.40 $0.00 Printed: Wednesday, January 28, 2015 10:28:55 AM 2 of 3 CR SVC7FM.S REMARKS, NOTES SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE INSPECTIONS COMPLETED RESULT DATE 0 BOND BEAM 0 FINAL" 70-1 FOOTINGS AOR Printed: Wednesday, January 28, 2015 10:28:55 AM 2 of 3 CR SVC7FM.S REVIEW TYPE REVIEWER i I SENT DATE I DUE DATE I R�DATEED I STATUS I REMARKS I NOTES , Printed: Wednesday, January 28, 2015 10:28:55 AM 3 of 3 C'R111/ GYS7FM5