05-1754 (AR)1 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: 05-00001754 79815 HORSESHOE RD 649-062-028-36 -2180 - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 78331 Tiht 4'0" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: LAWSER DAVID 79815 HORSESHOE RD LA QUINTA, CA 92253 s /,,�•\ Other struct info C 2005Contractor: UINT Owner FNDF LA ANCE DEPT QUINTA I DITION 2001 CBC LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: E FOOTAGE License No.: ' Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by ny plicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered'for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, a_ s owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Date: 10/11/05 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier 1.00 Policy Number NO I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 37,�0,,00r of the Labor Code, h wit c p with those i Date:��:JApplicant: c � J WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. , APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work,being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property r in pe n p oses. _ r Date/19 a/a-w Signature (Applicant or Agent): LQPERAIIT i Application Number . . . 05-00001754 Permit BUILDING PERMIT Additional desc . . Permit Fee . . . . 545.00 Plan Check Fee 354.25 Issue Date Valuation . . . . 78331 Expiration Date 4/09/06 Qty Unit Charge Per Extension BASE FEE 414.50 29.00 4.5000 THOU BLDG 50,001-100,000 ---------•-------------------------------7----------------------------------- 130.50 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 46.47 Plan Check Fee 11.62 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/09/06 Qty Unit Charge Per — Extension BASE FEE 15.00 899.00 .0350 ELEC NEW ---------------------------------------------------------------------------- RES - 1 OR 2 FAMILY 31.47 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15..00 Plan Check Fee .00 IssueDateValuation . . . 0 Expiration Date 4/09/06 _ Qty Unit Charge Per Extension BASE FEE ---=----------------------------------------------------------=------------- 15.00 Permit . . . MECHANICAL_ Additional desc . Permit Fee . . 24.00 Plan Check Fee 6.00 Issue Date_ Valuation 0 Expiration Date 4/09/06 '. Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 ---------------------------------------------------------------------------- Special Notes and Comments - 899 sq. ft. addition & 428 sq. ft. patio.October 11, 2005 3:29:16 PM- jjohnson ---------------------------------------------------- : Fees . . . . . ENERGY REVIEW FEE 35.43 LQPERMIT Application Number . . . . . 05-00001754 7 ------------------------------------------------------------------- Other Fees. . . . . . . . . . STRONG MOTION (SMI) - RES 7.83 Fee summary Charged --- - ------ Paid ---------- ---------- Credited ---------- Due ----------------- Permit Fee Total 630.47 .00 .00 630.47 Plan Check Total 371.87 .00 .00 371.87' Other Fee Total 43.26 .00 .00 43.26, Grand Total 1045.60 .00 .00 1045.60 057 CITY OF LA QUINTA SUB -CONTRACTOR LIST JOB ADDRESS 79- PE / /RMIT NUMBER OWNER—Dave- L ",1 e O LDER g/.� Ho�Se s/► � � This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this iob. Anv changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "un rue" is not an accepiauie reswilsc. :Ins. . ;>:::::: i....:::>:::: :::::::: ;:i::::::.....:; ........ :::: :::::::>: ensa..�::�:..............:..... .:::.r�,,..i,.. a...lnl.......i...�r..v ::.. .......::.:........... �...f nntraa.t^r_ - ...:...:::.::. �.�:: .:.<..__..- e::C�nt[a4`tOf,.S.::L.1C0n5e..:: .::. :::::::: ..::::::: ............ ......,, _-. ,.-................... P .......... .......... -- - - w — .r. ZN i0 I I 1 V C- 100 �6 0 S aF 0 3z�S" I,e s 3 a "ti..9 >< s ROOFIN:G>(.C,:3.::.}.:::.:::::::::...... n V _1Z ;;:.;;;�.;:;.:<.;;:.;:.;:.;:..:::: wi✓ e 1L CITVIIC Dw . X. -1'3 `<>> 2"'>;1' :NG........... ::::::.. D wr✓p�2 'ice OWNER/BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "Owner/Builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200.00 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the State and Federal Government as an employer and you are subject to several obligations include State and Federal income tax withholding, federal social security taxes, worker's compensation insurance, disability insurance costs and unemployment compensation contributions. There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owneis who are not licensed contracts are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/Builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. Very truly yours, CITY OF LA QUINTA DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico La Quinta, CA 92253 (760) 777-7012 FAX: (760) 777-7011 oa�_a_- ;Fi�- OWNER'S SIGNATURE/DATE 1717- F/S Hoese-A o R� PROPERTY ADDRESS 015--.1 7,5,f PERMIT NUMBER(S) CERTIFICATE OF COMPLIANCE Desert Sands Unified School District o yo 47950 Dune Palms Road BERMUDA DUNES 0 U= RANCHO MIRAGE Date 10/4/05 La Quinta, CA 92253 k_1 INDIANWELLS d� PALM LA QUINTA _' No. 27721 (760) 771-8515 ��OINDIO y7� Owner David Lawser APN # 649062-028 Address 79815 Horseshoe Rd Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Unit 1 79815 Horseshoe Rd 899 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Lot # No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garagestcarports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 899 S.F. or $2,013.76 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By OC/Wells Fargo - Davis Lawser Check No. 0009701857 Name on the check Telephone Funding Residential By Dr. Doris Wilson s Superintendent s +- r P. f Fee collected /exempted by Sh n McGilvrey Payment Recd $0.00 R $2013.76 wer/Ung"er` f • . ht Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will rve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting Title 2,4 Report CEC Approved 2001 Building Energy Efficiency Standards Job Name Lawser. Residence Add tigerTYOFLLAQUINTA 79-815 Horseshoe R aq UILDING & SAFETY DEPT. La Quinta, Ca. 9225 1 APPROVED FOR CONSTR CTION DA 6 BY Prepared For Dave Lawser 79-815 Horseshoe Road La Quinta, Ca. 92253 760-342-1777 Prepared By Jack LaFontaine CABEC Certified Energy Analyst R 01.03.262 r F�,MY 2005 EMSEnergyMqn4gement Services. HVAC /Energy Consulting Services 41-485 Adams Street, Unit C - Bermuda Dunes, Ca. 92203 (760) 360-4631 / Fax (760) 360-3074 C20 License No: 315890 - E-mail: freon.iackAverizon.net T24 Reports —HVAC Mechanical Design — Calif Certified HERS Rater — NBI Certified Air Balance Tests Cabec Certified Energy Analyst EMSEnergy. Management Services HVAC / Energy Consulting Services Note to Plan Checker, Inspectors & Builder Project Name: Lawser Residence Addition Job Number: 05052005 Project Designer: Dave Lawser This Building COMPLIES by 10.7% better than standard. SPECIAL FEATURES AND MODELING ASSUMPTIONS: • The existing heating and air-conditioning system is more than adequate to meet the heat and cooling loads for this 899 sgft addition. • The report includes a credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS REQUIRED VERIFICATIONS: • A certified HERS Rater must provide a duct leakage test on this zone. • A certified HERS Rater must provide verification of the TXV installed on the HVAC evaporator coil for this zone. • The HERS Rater must document the field verification and diagnostic testing of these measures on a.form CF -6R. 41-485 Adams Street, Unit C - Bermuda Dunes, Ca. 92203 - (760) 360-4631 / Fax (760) 360-3074 C20 License No. 315890 - E-mail: freon.iackAverizon.net T24 Reports — HVAC Mechanical Design — Calif Certified HERS Rater — NBI Certified Air Balance Tests — Cabec Certified Energy Analyst TITLE 24 REPORT Title 24 Report for: Lawser Residence Addition 79-815 Horseshoe Road La Quinta, Ca. 92263 Project Designer: Dave Lawser 79-815 Horseshoe Road La Quinta, Ca. 92253 760-342-1777 Report Prepared By: Jack LaFontaine Energy Management Service 41--485 Adams Street, Unit C Bermuda Dunes, CA 92201 760-360-4631 Job Number: 05052005 Date: 5/7/2005 FA The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft; LLC (415) 897-6400. EnergyPro 3.1 - By EnergySoft Job Number:. 05052005 User Number: 5021 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist. 6 Form C -2R Computer Method Summary 8 EnergyPro 3.1 By EnergySoft Job Number: 05052005 User Number: 5021 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Lawser Residence Addition 5/7/2005 Project Title Date 79-815 Horseshoe Road La Quinta Project Address Building Permit # Energy Management Service 760-360-4631 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 899 ft2 Average Ceiling Height: 10.3 ft Total Conditioned Slab Area: 899 ft2 Building Type: l (check one or more) 0.756 X❑ Single Family Detached X❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 0.31 - Number of Stories: 1 ❑ Raised Floor Component R-38 Roof (R.38.2x4.24) Slab On Grade R-19 Wall (W.19.24.16)w/1" EPS R-19 Wall (W.19.2z6.16)gyp/gyp FENESTRATION Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) Wood 0.027 Exterior Roof n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Wood 0.045 Exterior Wall Wood 0.060 Exterior Wall. Front (North) 13.3 Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (North) 13.3 0.33 0.40 Bug Screen o ❑ ❑ a Rear (South) 27.4 0.33 0.40 Bug Screen ❑ x❑ ❑ X❑ Rear (South) 56.8 0.33 0.40 Bug Screen x❑ ❑ ❑ x❑ Right (West) 10.6 0.33 0.40 Bug Screen ❑ , x❑ ❑ Q Right (West) 21.9 0.33 0.40 Bug Screen X❑ ❑ ❑ 0 Right (West) 141.8 0.44 0.42 Bug Screen x❑ ❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El EI 1:1 El 1:1 El El El 1:1 El El El Run Initiation Time: 05/07/05 09:36:56 Run Code: 1115483816 Ener Pro 3.1 By Ener Soft User.Number: 5021 Job Number: 05052005 Pa e:3 of 11 Certificate of Compliance: - Residential (Part 2 of D CF -1 R Lawser Residence Addition 5/7/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Cooling Equipment Minimum Type (air conditioner, Efficiency heat pump, evap. cooling) (SEER) Duct Location Duct Thermostat Location / (attic, etc.) R -Value Type Comments WATER HEATING SYSTEMS Rated 1 Tahk Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standbyy Tank Insul. System Name Type Type Syst.. Btu/hr (gal) Efficiency Loss ( 0) R -Value 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS Note: The existing heating and air-conditioning system s more than adequate to heat and cool this 899 sqft addition. '9wtight Contents EMS 2005 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Z5 Title/Firm: Dave Lawser Address: 79-815 Horseshoe Road La Quinta, Ca. 92253 Telephone: 760-342-1777 Lic. #: S - %-aDa3 r (signature) (date) f Enforcement Agency Name: Title/Firm: Address: Telephone: Name: Jack LaFontaine Title/Firm: Energy Management Service Address: 41- 485 Adams Street, Unit C Bermdda Dunes. CA 92201 (date) lEnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Paae:4 of 11 1 Certificate of Compliance: Residential (Addendum) CF -1 R Lawser Residence Addition 5/7/2005 Project Title ' Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oases on ine aaequacy or ine speciai jusuncation dna aocumenration suomittea. Plan I Field The HVAC System "%s" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 899 sqft Exposed Slab Floor, 3.50" thick at MBR Addition HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "%s" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "%s" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Paae:5 of 11 1 Mandatory Measures Checklist: Residential (Page -1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded.by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures [X] -§150(a): -§150(a): Minimum R-19 ceiling insulation. ❑§150(b): Loose fill insulation manufacturer's labeled R -Value. *§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑ X not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. F § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑ §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMAC NA or ACCA. ❑§150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater.. - 1 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Page:6 of 11 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION instructions: Check or initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X] I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating, b. Cover for outdoor pools or outdoor spas. i 3. Pool system has directional inlets and a circulation pump time switch. ❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5021 • Job Number: 05052005 Page:7 of 11 Computer Method Summary (Part 1 of 3) C -2R Lawser Residence Addition Project Title 5/7/2005 Date 79-815 Horse -,hoe Road I a Qtlinta Project Address Building Permit # Fnerav Management Service 760-360-4631 DocumWdtation Autfror • Telephone Plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.97 1.68 1.30• Space Cooling 36.46 33.56 2.90 Domestic Hot Water 0.00 0.00 0.00 Totals 39.44 35.24 4.20 Percent better than Standard: Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units; Number of Stories: 899 ft2 Single Fam Detached (North) 0 deg 0.31 1 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACES Solar Act. Gains Type Area U -Fac. Azm. Tilt Y / N Rnnf 899 0.027 0 99 X ❑ Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Total Fenestration Area: 30.2% Total Conditioned Volume: 9,287 ft 3 Total Conditioned Slab Area: 899 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area ReferenceForm 3 :•• 9-1 • 1 . 1V Ka VIATATF1 I WiTITA.11V • 1� 1� W. Location / Comments Additinn 899 cgft Additinn 89.9 Sgft Addition 899 sgff Additinn 89q cnft Additinn 899 sift Addition 899 sgff I EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Paae:8 of 11 1 Computer Method Summary (Part 2 of 3) C -2R Lawser Residence Addition 5/7/2005 Project Title Date FENESTRATION SURFACES 1 Bug Screen 0:76 2 Buq Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen U- 7 Bug Screen Act.. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments J__ Window Front (North) 13.3 0.390 0.40 �_ -90 Andersen (Lawser) Addition 899 sgft 2 Window Rear (South) 27.4 0.330 0.40 180 90 Andersen (Lawser) Addition 899 sgft 3 Window Rear (South) 56.8 0.330 0.40 180 90 Andersen (Lawser) Addition 899 sqft 4 Window Right (West) 10.6 0.330 0.40 270 90 Andersen (Lawser) Addition 899 soft 5 Window Right (West) 21.9 0.330 0.40 270 90 Andersen (Lawser) Addition 899 soft 6 Window Right (West) 94.5 0.440 0.42 270 90 Andersen (Lawser_ Addition 899 salt VA M INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 1 Bug Screen 0:76 2 Buq Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 Window _ Hgt. Wd. Len. 0.1 3.0 3.0 4.0 13.5 3.0 0.1 3.0 3.0 4.0 5.2 5.0 0.1 5.0 5.0 8.0 8.0 5.0 0,_1 5.0 5.0 8.0 6.0 5.0 0.1 5.0 5.0 Left Fin Dist. Len. Hgt. Dist. I EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Paae:9 of 11 1 r Computer Method Summary (Part 3 of 3) C -2R Lawser Residence Addition 5/7/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, He_ 4meight 899 3.50 _28 0 98 n/a 0Addition 899 soft / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 60 0.76 0.0 _ 0 . Addition 899 saft HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump,. evap. cooling) , (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Rated Tank Energy Fact! Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System ,Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (°/a) Ext. For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. rte: The existing heating and air-conditioning system more than adequate to heat and cool this 899 sqft addition. I EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Paae:10 of 11 1 Computer Method Summary (Addendum) 2-2R Lawser Residence Addition 5/7/2005 Project Title Date Special Features and.Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oases on the aaequacy OT the special JustiTIcation ano aocumentation sunmittea. Plan Field The HVAC System "%s" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 899 sgft Exposed Slab Floor, 3.50" thick at MBR Addition HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "%s" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "%s" is.using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Page:11 of 11 74 L PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Lawser Residence Addition 5/11/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asphalt Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 5 ASSEMBLY NAME R-38 Roof R.38.2x4.24 Gypsum or Plaster Board 7 0.20 8 2.88 ASSEMBLY Floor 2.08 INSIDE SURFACE AIR FILM 0.610 41.15 TYPE (check one) Wall 0 X Ceiling I Roof Fn 7 9 FRAMING MATERIAL wood > Fn p FRAMING % �% Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asphalt Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 5 Insulation, Mineral Fiber, R-38 6 Gypsum or Plaster Board 7 0.20 8 2.88 9 1.00 2.08 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.440 0.440 0.060 0.060 0.620 0.620 0.8001 0.800 38.000 11.385 0.450 0.450 0.20 0.01 2.88 0.35 1.00 2.08 0.610 0.610 41.15 14.53 KC KT *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 1.46 0.30 0.44 0.06 0.35 0.02 1.42 0.29 0.41 0.031 0.20 0.01 2.88 0.35 1.00 2.08 0.26 0'.54 7 9 TOTAL HC 2 4 `NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0243 X 0.93 ] + [ 0.0688 X 0.07 1 / Rc 1 - (Fr -/o /100) 1 / Rf Fr/6 1100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Page: 12 of 18 yr i. 1PROPOSED'CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Lawser Residence Addition —7. 5/11/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM ASSEMBLY NAME R-19 Wall .19.2x6.16 w/1" EPS stucco 2 Membrane, Vapor -Permeable Felt ASSEMBLY Floor Insulation, Polystyrene, Smooth Skin , 4 TYPE x Wall (check one) 5 W 0 W Ceiling I Roof 0.04 H FRAMING MATERIAL Wood 8 Q FRAMING % 15 %o Framing /o 0.54 15% (16" o.c. Wall) 0.680 25.54 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 stucco 2 Membrane, Vapor -Permeable Felt 3 Insulation, Polystyrene, Smooth Skin , 4 Insulation, Mineral Fiber, R-19 5 Gypsum or Plaster Board 6 0.04 7 0.37 8 2.08 9 0.54 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 5.000 5.000 19.002 5.940 0.4501 0.450 0.04 2.871 0.37 1.06 2.08 0.26 0.54 0.680 0.680 25.54 12.47 My KT 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0392 X 0.85 ] 8.46 0.201 1.69 0.06 0.35 0.02 0.15 0.29 0.04 2.871 0.37 1.06 2.08 0.26 0.54 13.6 TOTAL HC 3.4 "NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0392 X 0.85 ] + [ 0.0802 X L 0.15 ] 1 / Rc 1 - (Fr-/. / 100) 1 / Rf Fr% / 100 .ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Page:13 of 18 r PROPOSED CONSTRUCTION ASSEMBLY - ENV -3 PROJECT NAME DATE Lawser Residence Addition 5/11/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-19 4 Gypsum or Plaster Board 5 ASSEMBLY NAME R-19 wall .19.2x6.16 / 1.06 7 0.26 8 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 20.92 TYPE (check one) X Wall W p W Ceiling / Roof 0 FRAMING MATERIAL 2 3 p Z FRAMING % 15% Framing 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-19 4 Gypsum or Plaster Board 5 2.87 6 1.06 7 0.26 8 9 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 0.060 0.060 19.002 5.940 '0.450 0.450 2.87 0.37 1.06 2.081 0.26 0.54 0 .6801 0.680 20.92 7.86 Kc KT nen *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0478 X 0.85 ] 2.60 0.26 0.68 0.06 0.35 0.02 2.87 0.37 1.06 2.081 0.26 0.54 7 6 TOTAL HC 2 3 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0478 X 0.85 ] + [ 0.1272 X L 0.15 1 / Rc 1 - (Fr-/. /100) 1 / Rf Fr% 1100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 05052005 Page:14 of 18 1