Loading...
06-3368 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 4'e(f4 Q211d BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 4- 06-00003368 Property Address: 51340 CALLE HUENEME APN: 770-164-006- - - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: MEDIUM DENSITY RES Application valuation: 127930 Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: - Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued ISec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPEkN11T Owner: ROBERT ANCKER r1r, .51-340 CALLE HUENEME LA QUINTA, CA 92253 Contractor: Owner VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/11/07 JUL 112007 1 1 CITY OLA q INU TA WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided .�• for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section X35700 of the L or Code, I shallorthwi co ith those provisions. pplicant: 7 `moi► WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state. that the above information is corre I agree to comply with all city and county ordinances and state laws relating to building construction, d h by uthorize representatives of this countytoenter upon the above-mentioned prop r in ctio urp es. Da/tea Sig nat (Applicant or Agent): LQPERMIT •" Application Number _ 06-00003368 ------ Structure Information 2,025SF/V-NR/RES-3/CLASS A-FR ENGINEERED----- Other struct info . . . . . CODE EDITION 2001/2005 # BEDROOMS 3.00 'FIRE SPRINKLERS NO GARAGE SQ FTG 427.00 PATIO SQ FTG 173.00 ---------------------'------------------------------------------------------ NUMBER OF UNITS 1.00 Permit BUILDING PERMIT Additional desc . Permit Fee 737.50, Plan Check Fee 279.38 . Issue DateValuation'- y1/07/08 127930 Expiration Date Qty Unit Charge Per Extension BASE FEE 639.50 28.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,0017500,000 98.00 Permit . . . ELEC-NEW RESIDENTIAL .• Additional desc . Permit Fee . . . . 95:29 Plan Check Fee 23.82 Issue Date Valuation 0 Expiration Date 1/07/08 Qty . Unit Charge Per Extension BASE FEE 15.00 2050.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 71.75 427.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 8.54 Permit GRADING PERMIT . Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 1/07/08 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 88.00 Plan Check Fee 22.00 Issue Date . . . .. i Valuation . . . . 0 Expiration Date . . 1/07/08 LQPERMIT LQPERA11T Application Number 06-.00003368 Permit �. . . . . . MECHANICAL , Qty. Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH-FURNACE <=100K 18.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 9.0000 EA MECH B/C <=3HP/100K BTU .18.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 EA MECH EXHAUST HOOD --------------------L------------------------------------------------------- 6.50 ' Permit . . . PLUMBING Additional desc . Permit Fee . . . . 164.25 Plan Check Fee 41.06 Issue Date Valuation 10 Expiration Date 1/07/08 Qty Unit Charge Per - Extension BASE FEE 15.00 15.00 6.0000 EA PLB FIXTURE 90.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 6.0000 EA PLB ROOF DRAIN 6.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3:00 _ 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ------------------------------------------------------------- Special Notes and Comments -------------- 2,050SF DWELLING V-NR/RES-3/CLASS A -FR [ENGINEERED] - THIS PERMIT DOES NOT INCLUDE BLOCKWALLS, POOL -AND SPA, OR DRIVEWAY APPROACH. 2001 CBC, CMC, CPC, 2004 CEC, 2005 ENERGY. July 11, 2007 12:00:36 PM AORTEGA -------------------------------------------------------------=-------------- y Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 20.00 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 47.94 DIF FIRE PROTECTION -RES 140.00• HOURLY PLAN CHECK 200.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 12.79 DIF STREET.MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 LQPERA11T t LQPERD7IT M . Application Number 06-00003368 Fee summary Charged Paid- Credited Due Permit Fee Total 1100.04 .00 .00 1100.04 Plan Check Total 366.26 .00 .00 366.26 Other Fee Total 4755.73 200.00' .00 4555.73 Grand Total 6222.03 200.00 .00 6022.03 VII Wr JA ovo-LOVIM I I.I.VM Libi JOB ADDRESS- J-Ij6,4445" W,%t�a,_z4-4..PtRmr.r NUMBER" OW* NEk This form shaltbe posted on the.job with the Building Insgiectibn Card at all-tImes-In a cons mLQmIjA=. Only persons appdwring on.this fist or their employees are bdthoeized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failute to comply will result ina stoppage of work and/or the voidance ofbuilding permit. For each applicable trade, all information requested below tnustbe completed by applicant. 'On File* Is'not an acceDfable resnonse.' Trade I eiassifl6atiQn -:v �6ntrac 2C on dtfdjmjlriaur��*t ra company "am's Classiflcattan License Number Exp. Date Caviler Name Policy Number Exp. Date License Number Ekp. Date (e.g. A, B, 0-8) (XXXXXXI (xxlxxlxx) te.g. state Fun.d.. C8.1comp) • (Format Varies) txxlxxfxxl Ixxxx) fxx/xxlxx) ORTHWORK (C-121 �5x CA TI AJ ?;Iq CoNqm1- A) 0' Im Srf FRAlyliuc'iC 53 / 9ti•,0r) /J4 zy� nq -7 MIMI)' 2- PL 3 P�qWiNd (C-.3 GJ` UM1 T"' :C_ 8 17 .11,316 A101da d/iv DRYI� D�Yi4AL( ttECTYU t,LgCTRICA L rfy, Cion ::241AI-7 1 61-61 z_R1z,4LM,�—d,, rs, ep 54 7 _P7 C rim PORWO. _1 57W4 i"s/ V_ 7�' V IVSULAT[o. ic!i) PAINTING ('C 3 34 _Kqz CABINETS IC -6) FENCING ...' LANDSCAPING POOL (C-63) I LZ 'IC KID COKPLIq G 6/4-7 Date 5/9/07 No. 29415 Owner Robert Ancker Address City Zip Tract # Type Single Family Residence CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Qu i nta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # Study Area No. of Units z�oQ BERMUDA DUNES RANCHO MIRAGE d INDIAN WELLS �.� PALM DESERT ,y LA QUINTA , ��INDIO Sp O Y 770-164-006 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 51340 Calle Hueneme 2050 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 X 2,050 S.F. or $5,391.50 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By OC/Washington Mutual Bank - Robert Ancker Check No. 511410939 Name on the check T I h 310 474 5761 By Dr. Doris Wilson Superintendent Fee collected /exempt Signature e Up one Funding Residential, a , Payment Recd ;0:00-- $5,391.50 '`Jver/Under,: x�'.•� NOTICE: Pursuafnt to Government Code Section 66020(d)(1), this Jill serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the d e o hich the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original- Building Department/Applicant Copy -Applicant/Receipt Copy - Accounting '---� --- /] � CITY OF LA QUINTA� SUB-CONTRACTO LIST ,JOBADDRESS _ ` 0 PERMIT NUMBER OWNER ��S BUILDER This form shall be posted on the job with the Buildi139 Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job:. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response. Trade / Clas ton .. silica i Contractor ... , .: ':>.:::::State::Contracto .s License .. ...... .... r :.: :. :>.. : . W.,orkec$.Corrl ensaLon:tnsuranc� . . ::..... . it . Business License; :. . C Y Company Name . Classification (e.g. A,.B, C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier. Name (e.g. State_ Fund, CalComp) Policy Number (Format Varies) Exp. Date (xx/xx/xx) License Number (xxxx) Exp. Date (xx/xx./xx) EARTHWORK (C-121.:. CONCRETE (C-8) FRAMING ;IC -6) ..;: STRUCTS STEEL (G -5.a) PLUMBING (C-361 EATH; PLASTER (C=35) DRYWALL (C-9):-:::-. 1 HVAC. (C-20) ZE�d 2 -29L) ELECTRICAL. (C=10) RCIQFING'aC=391':<. SHEET METAL' (C-43) ` ?. FLOORING GLAZING (C-171.".` • :::.>:::::: . INSULATION (C-21. :.., SEWAGE DISP: (C-42) .. PAINTING (C=33) ' CERAMIC TILE (C-54)':.:.. .CABINETS (C-6) FENCING (C713). LANDSCAPING POOL (C-53) 17-2007 08:45 AM P. 02 Plan Number Sample GroupNUNber Sample Houle N4mber rider. Street Address:.7T&/& T & �'� C1I=%,_ t;dy/t3MUOP: 4• a —W!2& Copies to: 8tdider, HERS Provider djRSUL .STATE BNT The house was; Tasted ❑ Approved as pad of sample testing. but was not tested As tha HERB rater• providing dtVnwuc won and field veriticat9on. t certify that the housed; Identified on this foam co with tins diagnostic fesbsd compiler= re4uf►ements as aheaked on tars form. DIsMibution system is fuiiy ducted p.e.. does not use building cavities as planums or pistortn returns in Ileu dins) rubber adhesive _ mastic taPe Is Installed, here dam badwd.���� dust tape to seal taaW duet of oannections da are used In combination with doth backed, rub - MINIMUM REQUIRI.'NENTS FOR DUCT LEAKAGE REDUCTION COMPLIIANCE APR 2 1 2008 VVVDuct Diagnastle L 8*age T"Ung Rssu pbsimum 6% OWA t�kage) M Duct Pressurimlon Test Results (CFM Q 26 Pa) vaiu4 Test Lump Flow In CFM � ��— lf tan now is calculated as 400chn1t6n x number of tons enter calcuiated value here V fan now is measured enter measured value here Leakage Percentage (100 x Test Leakaga/Fan Flow) _ /' �/a '✓�� 6l Check Box far Pass or Fail (POO"% or less) ❑ ss Fail 0'THERmosTATLC ExpApisioN YAwra y -m or Commission approved equivalent r Yes ❑ No Thermostatic Expansion valve (or Com>nission approved ❑ equivalent) Is Installed and Access is provided for Inspection 001a Yes is a p®ss Fail [3 mlNIMUM REQUIREMENT3 FOR DUCT DESIGN COMPLIANCE CREDIT t O Yes D No ACOA Manual D DesIgn requirements have been met . (rater has verified that actual installation matches values In CFAR and design on plan. h been varMed. If no TXV, 2. O Yes E3 No ixv is installed a Fan flow as / verifled fan flow matches design horn CF. IR. Measured Fan flow Yes for both 1 and 2 Is a Pass Pass Fail August 14; 2007 Mt. Robert Ancker LANuMARK a MBE Company APR 21 2008 Ip Subject: Compaction Test Report 51-340 Calle Hueneme COIR 1/0�A California LCI Project No.: LP07219 Dear Mr.Ancker: 780 N. 4th Street EI Centro, CA 92243 (7601 370-3000 (760)337-8900 iax 77-948 Wildcat Drive Palm Desert, CA 92211 (760) 360-0665 (760) 360-0521 fax Attached is a summary report of compaction tests made of fill within the building pad on the subject project site. Placement and compaction of fill soils were not observed by our firm. The compaction tests were made in conformance to In-place Density by Nuclear Methods (ASTM 2922 & D3017) on July 18 thru July 25, 2007 the test results are attached. LIMITATIONS The tests results summarized in this reportpresent the moisture and density only at the locations f and elevations tested on the specified dates. The density testing was performed according to the generally accepted, geotechnical engineering standards of practice that existed in the County of Riverside at the time the report was prepared. No opinion is expressed as to the. uniformity of the material, compaction, nor adequacy of the material to perform as intended. No guaranty or warranty of the contractor's work is made or implied. The test locations are approximate, determined by pacing and sighting from distinguishable field features. In doing our work, we have relied on topographic and surveying information- provided by others. Mr. Robert Anckler LCI Project No.:LP07219 Natural or imported soils (if any) atone foot or below existing pad grade, were not investigated or tested by our firm. No warranty is made as to the stability/density of these soils. With any manufactured product, there are statistical variations in its uniformity and in the accuracy of tests used to determine its quality. As compared to other manufactured .products, field placement of materials usually presents large statistical variations in its uniformity and in the accuracy of the test results. Thus, even with careful observation and. testing, all parts of the constructed product may not comply with the job requirements. Therefore, our opinion means that there is only a statistically -based probability that the densities obtained comply with the job requirements. This report is issued with the understanding that the owner or his representative has the responsibility to insure that this report is submitted to the appropriate governing agencies. Please review the test results and contact our office with any questions or comments. Sincerely yours, Landmark Consultants, Inc. C9 P.E. g L No. C 34432 EXPIRES 09-30-07 Landmark Consultants, Inc. Summary of Laboratory Tests Maximum Density - Optimum Moisture (ASTM D1557) Client: Mr. Robert Anckler Project Name: 51-340 Calle Hueneme Project No:: LP07219 Legend: FP: Finish Pad N: Nuclear Gauge P: Pass F: Fail IVIax. Opt. Mat. Density Moisture Type Description USCS (pcb (%) 1 Gray brown silty sand SM 116.0 12.5 a Legend: FP: Finish Pad N: Nuclear Gauge P: Pass F: Fail Landmark Consultants, Inc. Compaction. Test Summary Client: Mr. Robert Anckler Project: 51-340 Calle Hueneme Project No.: LP07219 T"Qf Af- Wrtne'. Parle {.::5' ! 5� f"?.�- r�v ' v..L',v . Y='� :, ` � i i° i2�� _YP .+.'4'yT_ry '� }�': �" ^..h'. TSt �� a Sr}l� .y •,.yam '� fir in" G' v ;.t 1 07/18/07 S/W comer of pad I FP 113.7 8.6 116.0 98 P 2 07/18/07 S/W comer of pad I FP -1' 92.0 20.0 116.0 79 F N 3 07/18/07 N/E comer of pad I FP 82.0 8.5 116.0 71 F N 4 07/1.8/07 N/E comer of pad I FP -l' 90.8 14.0 116.0 78 F 14 5 07/23/07 Retest of Test # 3 1 FP 102.9 5.0 116.0 89 F N 6 07/23/07 Retest of Test # 2 1 FP -1' 83.3 24.1 116.0 72 F N 7 07/23/07 Retest of Test # 4 1 FP. 101.2 9.7 116.0 87 F N 8 07/25/07. Retest of Test # 6 I'l FP -1- 106.6 10.0 116.0 92 P N .9 07/25/07 Retest of Test #7 1 FP 104.0 12.0 1 116.0 90 P N 10, 07/25/07 Retest of Test # 5 1 FP 104.7 11.0 116.0 90 P N .Se ` TITLE 24 REPORT 0 t Title -24 Report for: HACIENDA ADOBE 51340 Calle Hueneme La Quinta,'CA 92253 Project Designer: LENCH DESIGN STUDIO INC P O BOX 450 LA QUINTA, CA 92247-0450 760/564-1866 Report Prepared By: VERNA LENCH Lench Design Studio, Inc. P.O. Box 450 FJUN La Quinta, CA 92247-0450 2 2 2007 (760) 564-1866 V-&. CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. APPROVED VL -1406 FOR CONSTRUCTION ' DATE « BY Date: 11/22/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: VL -1406 User Number: 5454 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 8 10 11 13 15 17 EnergyPro 4.3 by EnergySoft Job Number: VL -1406 User Number: 5454 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R HACIFNDA ADnRF Project Title 11/22/2006 Date Calle Hueneme I a Quints _51340 Project Address Building Permit # Lench Design Rtudic, Inc -(760) 564-1866 Documentation Author Telephone plan Check/Date _FneraVPro Compliarice Method 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.43 2.65 0.78 Space Cooling 68.24 70.53 -2.29 Fans 9.61 10.05 -0.44 Domestic Hot Water 11.36 3.37 7.99 Pumps 0.00 0.26 -0.26 Totals 92.64 86.87 5.78 Percent better than Standard: 690/1, Building Type: (Z Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (W) 270 deg Natural Gas Area: 483 ft2 Avg. U: 0.39 Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: 2,050 ft2 n/a ft2 0 ft2 2,050 ft2 10.5 ft 1.00 Ratio: 23.6% Avg. SHGC: 0.32 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC'- Zone 1 1n9R 9 n.9; n 53 Conditioned Setback- 2 ala HVAC - Znne 2 954 954 0.47 Cnnditinned Sethark n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Bnnf Wnnd 1 nqq n n25 R -RR R -n n 270 p Wall Wnnd 3R n 056 R_19 R-4.5 27n _gn Donr Anne 24 n 500 Nnne R -0 .n 270 Ap Wall Wnnd 53 n 056 R_19 R-4_5 1Rn _gQ Wall Wnnd 94 n"0% R-19 R-4.5 270 9Q Wall Wnnd 211 n 05 R_19 R-4.5 An Wall Wnnd R9 n n74 R_13 R-4 5 _dPII Wall Wnnd 4A n n56 RAP R_4 5 _Af) An Wall Wnnd 16n n_n74 R_13 R-4"5 1Rn AQ Wall Wnnd 1gn n im R_13 R_0"0 270 9Q nnnr Nnne 17 n 500 Nnne R -n n 27n Ap Wall Wnnd RR n n74 R_13 R-4_5 1Rn _gp Rn�f Wood A54 0 n9ri R_39 R-0.0 27n Q Wall Wnnd 26A n.074 R_13 R-4.5 _n An Wall Wnnd 34n 0.074 R-13 R-4.5 AdAn Wall Wnnd 232 n.n74 13_13 R-4.5 180 AIl Wall Wnnd 104 n 074 R_13 R-4 5 n An Wall Wnnd 11ri n_n74 R_13 R-4 5 1Rn A(1 Wall Wnnd 4n p 074 R_13 R-45 270 9f) Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 Page:3 of 19 1 Certificate'Of Compliance : Residential (Part 2 of 4) CF -1 R HACIENDA ADOBE 11/22/2006 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazi J-- Skylght Front (W) 4.0 n Sq NFRC-OM 2 Window Front (W) 4.5 0.370 NFRC 0.32 3 Window Front (W) 72.0 0.370 NFRC 0.32 4 Window Front (W) 15.5 0.370 NFRC 0.32 5 Window Left (N) 4.5 0.370 NFRC 0.32 6 Window Left (N) 4.0 0_370 NFRC0 32 L Window Rear (E) 48.0 0_370 NFRC 0_32 8 Window Right (S) 30.0 0.370 NFRC 0.32 6 Window Right (S) 48.0 0_370 NFRC 0_32 -M Window Left (N) 30.0 0=370 NFRC 0_32 -U Window Left (N) 6.0 0_370 NFRC 0_32 12 Window Left (N) 6.0 0.370 NFRC 0_32 Aa Window Rear (E) 30.0 0=370 NFRC 0_32 14 Window Rear (E) 30.0 0.370 NFRC 0_32 15 Window Right (S) 7.5 0.370 NFRC 0_32 16 Window Right (S) 12.0 0.700 NFRC 0_38 17 Window Right (S) 6.0 0.370 NFRC 0_32 18 Window Left (N) 30.0 0.370 NFRC 0.32 -M Window Left (N) 14.0 0_700 NFRC 0_38 Location/ Comments NFRC 270 New Skylight - nual Glaze ZONE 1 NFRC 270 90 New IWC 5300 Vinyl/Low-E ZONE 1 NFRC 270 90 New IWC 5300 Vinyl/Low-E ZONE 1 NFRC 270 90 New IWC 5300 Vinyl/Low-E ZONE 1 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 1 -NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 1 NFRC 90 90 New IWC 5300 Vinyl/Low-E ZONE 1 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 1 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 1 NFRC 0 90 New IWQ 5300 Vinyl/Low-E ZONE 2 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 2 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 2 NFRC 90_ ._9.Q New IWC 5300 Vinyl/Low-F- ZONE 2 NFRC 90 90 New IWC 5300 Vinyl/Low-E ZONE 2 NFRC 180 90 New I_WC 5300 Vinyl/Low-E ZONE 2 NFRC 180 90 New Glass Block ZONE 2 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 2 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 2 NFRC 0 90 New Glass Block ZONE 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # _ Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist Len Hgt. Dist Len Hgt 1 None 1.00 2 Bug Screen 0.76 1.5 3.0 12.0 0.1 12.0 12.0 3 Bug Screen 0.76 8.0 9.0 8.0 0.1 8.0 8.0 4 Bug Screen 0.76 1.7 9.0 8.0 0, 8.0 8.0 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 21 None No Insulation 26-A1 New ZONE 1 Slab Perimeter 91 None No Insulation 26-A1 New ZONE 1 Slab Perimeter 135 None No Insulation 26-A1 New ZONE 2 Run Initiation Time; 11/22/06 07.18.42 Run Code: 1164208722 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 PageA of 19 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R HACIENDA ADOBE 11/22/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 2a Windnw Right (S) '30 Q _0-37 NERC X32 NFRC 180 —9D_ New IWC 5500 Vinyl/1 ow -F ZONE 2 21 Window Right (S) 3.0 0.370 NFRC 0_32 NFRC 180 90 New IWC 5300 VinWLow-E ZONE 2 22 Window Front (W) 48.0 0.370 NFRC 0_32 NFRC 270 90 New IWC 5300 Vinyl/Low-E ZONE 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt Wd Len Hgt LEA RExt Dist Len H t Dist Len H t 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 11/22/06 07:18:42 Run Code: 1164208722 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 Page:5 of 19 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R HACIENDA ADOBE Heating Cooling Duct Location 11/22/2006 Project Title HVAC - Zone 1 Ducted Ducted Date HVAC SYSTEMS New Yes HVAC - Zone 2 Ducted Ducted Attic Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC - Zone 1 Split Heat Pump 8.90 HSPF Split Heat Pump 14.0 SEER New Setback HVAC - Zone 2 Split Heat Pump 8.90 HSPF Split Heat Pump 14.0 SEER New Setback HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct Condition R -Value Status Ducts Tested? HVAC - Zone 1 Ducted Ducted Attic 4.2 New Yes HVAC - Zone 2 Ducted Ducted Attic 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (al) Status or RE Loss (%) Ext Laars JVH075LD(I/L) Instant Gas Recirc/Time+Temp 1 75,000 0 New 0.82 750 n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and ce ' and field verification by an approved HERS rater. Designer or Owner (per Busi ess & Professions e) Documentation Author Name: Name: VERNA LENCH Title/Finn: LENCH DESIA STUDIO ItZ Title/Firm: Lench Design Studio, Inc. Address: P O BOX 450F Address: P.O. Box 450 LA QUINT CA 92247"0450 La Quinta, CA 92247-0450 Telephone: 760/564-A66 M Tel p ne: 760) 56 18 6 (signature) (date) (signature) (date) Name: Title/Firm: Address: Telephone: (signature) (date) 1m Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R HACIENDA ADOBE 11/22/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the .uvyuacy v1 urn spnciai Jusuncauon anu uocumema[ion suominea. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- ���-....J Plan �rr"•v" IZG; r1.. WWO UQ111y —. aNNw.ou wauny anmo1 vvnncauvn mutnoos anu muse oe reponea on ine Gr -4K installation certificate. plan Field The HVAC System "HVAC - Zone 1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC - Zone 1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC - Zone 2" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC - Zone 2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. I EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 Page:7 of 19 1 Mandatory' Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ RX ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ Q ❑ apply to exterior mass walls). ❑ ❑X ❑ •§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑X ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 onty. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑X ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El ER EJ Form: ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfittration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ 0 ❑ 3. Exterior doors and windows wealherstripped; all joints and penetrations caulked and sealed. ❑ -1 ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. ' 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 1 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping Includes a vapor retardant or is enclosed ❑ ❑X ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑X ❑ EnergyPro 4.3 by EnergySoft User Number. 5454 Job Number: VL -1406 Page:8 of 19 Mandy Measures Summa : Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ 0 ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ b. Cover for outdoor pools or outdoor spas. ❑ Q ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ Q ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ 0 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section 199(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number. 5454 Job Number. VL -1406 Page:9 of 19 i Residential Kitchen Lightinq Worksheet WS -5R HACIENDA ADOBE 11/22/2006 Project Title ; Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately. i Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Watts Quantity High Efficacy Watts Other Watts (1) 22w Fluorescent Circline Rapid Start Yes X No 27.0 x 2 = 54 or Compact Fluorescent Trip/Quad 4pin Yes X No (Ere 94.0 x 1 = 94 o r c2w Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes Nox = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes Nox = or F Total A: 148 B: 0 COMPLIES IF A z B YES ® NO ❑ EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 Paae:10 of 19 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HACIENDA ADOBE 11/22/2006 SYSTEM NAME FLOOR AREA HVAC - Zone 1 1,096 (Number of Svstems 1 11 Heating System Output per System 0 Total Output (Btuh) 0 Output (Btuh/sqft) 0.0 Cooling System Output per System 34,600 Total Output (Btuh) 34,600 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 31.6 Total Output (sgftrron) 380.1 Air 5vstem CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions (EATING SYSTEM PSYCHROMETRICS 26.0 OF. 68.6 of 68.6 of Outside Air o 0 cfm 68.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 529 15,477 1814 397 16,313 0 1,860 1,247 0 0 0 0 0 0 0 0 0 1,860 1,247 19 197 1,8141 18 806 Quo 855 Rheem RPPA-037JA 28,740 0 0 0.78 96.5 0.o Total Adjusted System Output28,7ao 0 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am am Tel 110.0 OF Supply Fan Heating Coil 855 cfm NG SYSTEM PSYCHROM 11.0 / 77.6 of ;l Outside Air 0 cfm 80.0160.4 ° F h Return Air Ducts '1 80.0 / 60.4 of 80.0 / 60.5 of . 48.5 / 46.9 of r Supply Fan Cooling Coil 855 cfm h Return Air Ducts `I Supply Air Ducts 108.6 of ROOMS 70.0 of Supply Air Ducts 50.5 / 47.8 of 33.5% R.H. ROOMS 78.0 / 59.7 of EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 Paae:11 of 19 1 i HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HACIENDA ADOBE 11/22/2006 SYSTEM NAME FLOOR AREA HVAC - Zone 2 ASa :ATING S 26.0 OF — ?, ;A Outside Air 0 cfm 68.6 OF Total Room Loads eturn Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts OTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 54 15,788 1,682 408 16,760 0 1,897 1,281 0 0 0 0 0 0 0 0 0 1,8971 1 1,281 19.5:8:2[:::j;82 19 321 Rheem RPPA-037JA 28,730 0 0 Total Adjusted System Output 28,730 0 J (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am I RICS (Airstream Temperatures at Time of Heatina Peak) 68.6 OF 68.6 OF rm 110.0 OF Supply Fan Heating Coil 855 cfm Supply Air Ducts 108.6 OF ROOMS 70.0 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 OF 80.1 / 60.4 OF 80.1 / 60.4 OF 48.5 / 46.9 OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 50.6 / 47.9 OF 855 cfm 33.3% R.H. ROOMS 80.1/60.4 F ° 78.0 / 59.7 OF 4.3 User Number: 5454 Return Air Ducts Job Number: VL -1406 2of19 ROOM LOAD SUMMARY PROJECT NAME HACIENDA ADOBE DATE 11/22/2006 SYSTEM NAME HVAC - Zone 1 FLOOR AREA 1,096 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 1 ZONE1 1 529 15,477 1,814 529 15,477 1,814 397 16,313 PAGE TOTAL 1 529 15,477 1,814 397 16,313 TOTAL 1 529 15,477 F 1,81411 397 16,313 EnergyPro By EnergySoft User Number: User Job Number: VL -1406 Page: 13 of 19 ROOM LOAD SUMMARY PROJECT NAME HACIENDA ADOBE DATE 11/22/2006 SYSTEM NAME HVAC - Zone 2 FLOOR AREA 954 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 2 ZONE 2 1 541 .15,788 1,682 541 15,788 1,682 408 16,760 PAGE TOTAL 1 5411 15,788 1 1,682 408 16,760 TOTAL 1 541 15,788 1,682 408 16,760 EnergyPro By EnergySoft User Number: User Job Number: VL -1406 Page:14 of 19 ROOM HEATING PEAK LOADS Project Title Date HACIENDA ADOBE 111/22/2006 Room Information Desicin Conditions Room Name ZONE 1 Time of Peak Jan 12 am Floor Area 1,096 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value Z�T of Btu/hr - Uua1 -Grade -Grade III w/1" oor )0 Vinv 311 w/1" all w/1„ Vin )0 Venv 311 w/1" )0 Vinv ally )0 Vinv 11 w/1" )0 X/Wn all W/1"" )0 Vinv 10 Von 3II oor 1092.0 x X x x X x X X x x x X X X x x X X x x X X X x x x X X X X x x x x X X x X x 0.0250 X X X X X X X X X X X X X X x X x X X x X X X x X X X X x x X x x X X x x x X 44 = = = = = = = = = = = = = = = = = = 1,201 4.0 0.5900 44 104 perimeter = 20.7 0.7300 44 665 perimeter = 91.4 0.7300 44 2,936 38.2 0.0555 44 93 24.0 0.5000 44 528 4.5 0.3700 44 73 52.8 0.0555 44 129 0,0555 44 229 72.0 0.3700 44 1,172 15.5 0.3700 44=252 210.6 0.0555 44 514 4.5 0.3700 44 73 89.0 0.0743 44= 291 0.3700 6.5 48.2 0.0555 44 118 44 7 160.0 0.0743 44=523 30.0 0.3700 44 488 48.0 0.3700 44 781 0,1020 44 8 53 17.0 0.5000 44 374 88.0 0.0743 44 288 Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 12 533 Infiltration: I1 1.001 x 1.064 x 1 096 x • 11.00 x 0.402 / 6] x ® = 3 780 chedule Air Sensible Area Calling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,313 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 Page: 15 of 19 , ROOM HEATING PEAK LOADS Conduction Area U -Value AT of Btu/hr 954.0 ped meter =135.1 268.0 30.0 6.0 6.0 340.0 30.0 30.0 231.5 7.5 12.0 6.0 104.0 30.0 14.0 115.0 30.0 3.0 40.0 X X x X X x x X x x x x X x x x x x X X x x x x x x x x x x x x x x x x x x x 44 = = = = = = = = = = =488 = = = 1,049 44 4,339 44 876 44 488 44 98 44 98 44 1,112 44 488 44= 488 44 757 199 44 370 44 98 44= 340 44 431 44 488 44 49 44 131 7111 Items snown Win an astehSK (") Genote conauctlon through an Interior surface to another room. Page. Total: 13 470 Infiltration: 1.00 1 x 1.os4 x s5a x 10.00 x 0.442 / 60] x 0 = 3 2so chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,760 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 Page:16 of 19 RESIDENTIAL ROOM COOLING LOAD SUMMARY opaque aurraces R-38 Roof Attic R-19 Wall w/1" EPS Interior Wood Door R-19 Wall w/1" EPS Interior R-19 Wall w/1" EPS Interior R-19 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-19 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior Orientation Area Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 90 Internal Gain Occu ants B4 E ui ment 1 U -Factor x 0.0250 X x 0.0555 X x 0.5000 X x 0.0555 X x 0.0555 X x 0.0555 X x x 0.0743 X X 0.0555 x 0.0743 X X 15.5X X X 38.3= X X 19.3 X CLTD 1 Btu/hr 1,529 70 396 76 172 269 152 88 309 Page Total 1 3.061 Orientation Shaded Area X x X X GLF + + + + Unshaded Area X X X Page GLF = = _ = = (Sky) 0.0x 26.4+ 4.0x 77.8= W 4.5X 19.3+ 0.0x 38.3= W 56.7X 19.3+ 15.3X 38.3= W 15.5X 19.3+ 0.0X 38.3= N 0.0 19.3 4.5 19.3 N 0.0 19.3 4.0 19.3 E 0.0x 19.3+ 48.0X 38.3= S 0.0x 19.3+ 30.0X 19.3= S 0.0x19.3+ 48.0X 19. F�x Total X Occupants X 230 Btuh/Occ. = X Dwelling Units X 1,6001 Watts/sgft = Btu/hr 311 87 1,678 299 87 77 1,837 580 929 5,8851 Btu/hr 920 1,600 Infiltration: 064 x 0 x 69.44 x = 2,921 Alr Sensible CFM ELA �T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15477 Latent Gain Occu ants 0 X Occupants X 1 2001 Btuh/OCC. Btu/hr 800 Infiltration: 4 7t X 1.16 X 69.44 X 0.00263 = 1,014 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,814 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 Page: 17 of 19 r RESIDENTIAL ROOM COOLING LOAD SUMMARY opaque burraces R-38 Roof Attic R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior Orientation Area X X X X X X X X X X X X U -Factor X X X X X X X X X X X X CLTD 1 = = = = = = W 954.0 0.0250 56.0 N 372.0 0.0743 23.0 E 340.0 0.0743 33.0 S 231.5 0.0743 26.0 S 115.0 0.0743 26.0 W 40.0 0.0743 33.0 0.0x 19.3+ 30.0X 38.3= S 0.0 19.3 7.5 19.3 S 0.0x 28.1+ 12.0X 28.2 S 0.0 19.3 6.0 19.3 N 0.0x 19.3+ 30.0X 19. Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 5060 XO Window 4016 XO Window 1020 (3) FO Window 5060 XO Window 5060 XO Window 1016 (5) FO Window 3040 GL BLK Window 3020 XO Window 5060 FO Window 3640 GL BLK Internal Gain Occu ants B4 E ui ment 1 nage I otal Orientation Shaded Area X X x x X GLF + + + + + Unshaded Area X X x x X1 Page GLF = = = = I N 0.0x 19.3+ 30.0x 19.3= N 0.0 19.3 6.0 19.3 N 0.0 19.3 6.0 19.3 E 0.0x 19.3+ 30.0X 38.3= E 0.0x 19.3+ 30.0X 38.3= S 0.0 19.3 7.5 19.3 S 0.0x 28.1+ 12.0X 28.2 S 0.0 19.3 6.0 19.3 N 0.0x 19.3+ 30.0X 19. N O.Ox 28.1+ 14.Ox 28.1= Total Btu/hr Btu/hr Btu/hr X Occupants X 230 Btuh/occ. = 920 X Dwelling Units X 1,60011 Watts/sqft = 1 1 600 Infiltration: 1 064 X 16 X 60.45 X � = 2 542 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,7881 Latent Gain Btu/hr Occupants X Occupants X 1 200 Btuh/OCC. = 800 Infiltration: 4 771 x 1.16 x 60.45 x 0.00263 = 882 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,682 EnergyPro 4.3 by EnergySoft User Number. 5454 Job Number: VL -1406 Page: 18 of 19 RESIDENTIAL ROOM COOLING LOAD SUMMARY ue burtaces Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration (Window 6080 SL DR I Internal Gain Occu ants E ui ment 1 Page Total Orientation X x x x x x x x x x x x X X X X x X X X X x x x x x x x x x x x x + + + + + + + + + Unshaded Area X x X x X x X X X GLF S 0.0x 19.3+ 30.0x138.3 S 0.0 19.3 3.0 W 0.0x 19.3+ 48.0X Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration (Window 6080 SL DR I Internal Gain Occu ants E ui ment 1 Page Total Orientation Shaded Area X X X X x X X X X GLF + + + + + + + + + Unshaded Area X x X x X x X X X GLF S 0.0x 19.3+ 30.0x138.3 S 0.0 19.3 3.0 W 0.0x 19.3+ 48.0X x Occupants X 230 Btuh/OCC. = x Dwelling Units x 1,600] Watts/sgft = Page Total Btu/hr 580 58 1,837 2 476 Btu/hr 920 1.600 Infiltration: 1.064 x 1 6 x 60 45 x = 2.5421 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,7881 Latent Gain Occu ants 0 X Occupants X 200 Btuh/oCC. _ Btu/hr 800 Infiltration: 4 7t x 1.16 x 60.45 x 0.00263 = 882 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,682 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1406 Page: 19 of 19