05-5043 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
05-00005043
Property Address:
575-7-0 INTER-LACHEN
APN:
762-180-022- -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
16791
Applicant: Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
--------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License �ClasbB �fLicense/N'�o.: 744540
ate:Contractor. AM 'V ee (� sX -
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
I—) Las owner of the property, or my employees with wages as their sole compensation,, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds orimproves thereon, and who contracts for the projects with a contractor(s) licensed.
pursuant to the Contractors' State License Law.).
1 I I am exempt under Sec. , B.&P.C. for this reason
'bate:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: —
Lender's Address:
LQPERMIT
Owner:
M/M ROGER SCHLESINGER
57-570 INTERLACHEN
LA QUINTA, CA 92253
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/17/06
Contractor:
NEXT STEP CONSTRUCTION
78825 VIA VENTANA
LA QUINTA, CA 92247 ��� 1 f41666
(760)275-7889 '
Lic. No.: 744540 - - C1OF
lA[]Iu..__
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier EXEMPT Policy Number EXEMPT
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forth th comply with those//Wno/vissiio+ns.s. /�
Date: Applicant: DEQ_ % /V fisc r s l C C)jJJ I ,
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
- the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
1 certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building constructi�^, and hereby authorize representatives
of this county to enter upon the above-mentioned property forr..innss�pe 1`-' purposes.
Date:.. . ignature (Applicant or Agent): ,./ r►%w+-¢��
r _
Application Number . . . . . 05-00005043
Permit
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
180.00 Plan Check Fee
117.00
Issue Date
Valuation . . . .
16791
Expiration Date
10/14/06
Qty _ Unit Charge
Per
Extension
BASE FEE
45.00
15.00 9.0000
----------------------------------------------------------------------------
THOU BLDG 2,001-25,000
135.00
Permit . . . .
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . .
29.28 Plan Check Fee
7.32
Issue Date . . . .
Valuation
0
Expiration Date
10/14/06
Qty Unit Charge
Per
Extension•
BASE FEE
15.00
408.00 .0350
---------------------------------------=------------------------------------
ELEC NEW RES - 1 OR 2 FAMILY
14.28
Permit . . .
MECHANICAL
Additional desc .
Permit Fee . . . .
46.00 Plan Check Fee
11.50
Issue Date . . . .
Valuation
0
Expiration Date
10/14/.06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 9.0000
EA MECH FURNACE <=100K
9.00
1.00 9.0000
EA MECH B/C <=3HP/100K BTU
9.00
2.00 6.5000
----------------------------------------------------------------------------
EA MECH VENT FAN
13.00
Permit . . .
PLUMBING
Additional desc .
Permit Fee . . . .
45.00 Plan. Check Fee
11.25
Issue Date
Valuation . . . .
0
Expiration Date
10/14/06
Qty Unit Charge.
Per
Extension
BASE FEE
15.00
3.00 6.0000
EA PLB FIXTURE
18.00
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
3.00 3.0000
EA PLB GAS PIPE 1-4 OUTLETS
9.00
----------------=---------------------------------------------------=--------
Special Notes and Comments
408 sq. ft. adition under
existing roof
LQPERMIT
Application Number . . . . .
05-00005043
----------------------------------------------------------------------------
Special Notes and Comments
line convert garage to living
space.
and patio addition.March 22,
2006
9:46:3.6 AM jjohnson
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
ENERGY REVIEW
FEE
11.70
STRONG MOTION
(SMI) - RES
1.67.
Fee summary Charged
Paid
Credited
Due
- ----------
Permit Fee Total 300.28
---------- ----------
.00
----------
.00
300.28'
Plan Check Total 147.07
.00
.00
147.07
Other Fee Total 13.37
.00
.00
13.37
Grand Total 460.72
.00
.00
460.72
`Bim# 40
4 vV
City of La Quinta
Building U Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
PeFmit #
��
Project Address: 57_ 570 ,� J TER Z A e 4 EN
Owner's Name: My-. i M rs . Rager r SC n l e 51 r e Y
A. P. Number: 7(.2-190-.6 omp> 6i�Fi
Address: 5 7. 5 701 h e, IACt:' f�leiV1
Legal Description:City,
ST, Zip: 'i.O' Q.Ct,4,yl�pt CA 9 22 $ 5 3
Contractor: A ex l#';KrST,6P C,,+t7c
elephone:
Address:
Project Description:
City, ST, Zip:
Ml vl D ✓ GtGL •�! ✓Lt -
Telephone: ..
]City
State Lic. # : 7tlV Yo
Lic. #:
Arch., Engr., Designer: C—I VM J 1 ?g 1 h ,(,(d 10
-- r00Aj-(6 A-,
Address: 73 _ 312 C.02 CU D r • i l u .
to q - pa7-( b
City, ST, Zip: PX6 JJmes'/At CA g2260
1
Telephone: 760 _ 9_ 5 91 &
Construction Type: Occupancy:
State Lic. #:
Project type (circle one): New dd' Alter Repair Demo
Name of Contact Person: 14a m 1
Sq. Ft.: p
# Stories:
# Units:
Telephone # of Contact Person: %P6— 771,519(p
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
I!
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
2
Plan Sets
Plan Check submitted
(
tem
Amount
2
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Pers 10
1
Plan Check Balance
Energy Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for correctins/issueraz,
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
"d Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
f
Total Permit Fees
I �S els ('� �/eQ,exo,o- (,IS r j Dogs
44IC6 Pis Pcap �p
F
roachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/MD. AMOUNT:
DATE:
RECEIPT:
CHECK #:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: RogerSchlesinge
Owner's Name: Roger Schlesinger
Project Address: 57-570 Interlachen, La Quinta, CA
Project Description: Room Addition
APN: 762-180-022
Tract #:
Date: April 17, 2006
Phone No. (
Lot #'s:
Type of Development: Residential XX Commercial Industrial
Total Square Feet of Building Area: 480 sq. feet
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign op behalf of the owner/developer.
Dated: 04/17/06
Signature:
a.—
***********************************************************************
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code Project
65995 Approval
480 sq. ft.
$ 0.00
$ 0.00
Agreement Existing Not Subject to Fee
Prior to 1/1/87 Requirement
Note: Pursuant to AB -181, any mobilehomes being replaced
or relocated within the same school district are exempt from
developer fees. Any additions of 500 sq. ft. or less is also
exempt from developer fees. (Unless additions are on a
structure that is under construction.)
Building Permit Application Completed: Yes/No
By: Carey M. Carlson, Asst. Supt., Business Services
Certificate issued by: Leticia C. Torres, Facilities Analyst Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMVN.T"OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance.
"v1 V:�hss} lt;�sr'de� CLe:� el iif i:at.e of amtplianc� i:unn rahle;'('C� [?tit.dcsc 1/16/03 T
I TITLE 24 REPORT I
Title 24 Report for:
MR. & MRS. ROGER SCHLESINGER
57-570 INTERLACHEN, PGA WEST
LA QUI NTA, CA 92253
Project Designer:
SHENASI DESIGN STUDIO
46-045 OCOTILLO DR. #2
PALM DESERT, CA 92261
(760) 779-5996
Report Prepared By:
ADRIANA GIL
Adriana Gil
7 :-854 Velie Way Ste. #8
Palm Desert, CA 92260
(760) 404-7917
Job Number: LA QUINTA
ADY295-1005 CITY OF
BUILDING & SAFETY DEPT*
AP P ROVEION
Date: FOR CON
ST DATE3 6 BY
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com. .
EnergyPro 4.0 by EnergySoft Job Number ADY295 1005 - User Number: 5553
TABLE OF CONTENTS
Cover Page - 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 7
HVAC System Heating and Cooling Loads Summary 9
}
EnergyPro 4.0 by Energysoft Job Number: ADY295-1005 User Number: 5553
Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R
MR & MRS- ROGER
SCHLESINGER
❑ Addition
n/a
11/13/2005
Project Title
Building Front
Orientation:
(South)180 deg
Date
57-570 INTER[ ACHEN.
PGA VVES_T LA-aWhLTA
Fenestration:
ft
Number of Dwelling Units:
Project Address
53 ft 2
Avg. U: 0.34
Ratio:
13.0% Avg. SHGC: 0.28
Building Permit #
Adriar_ta-Gil
Zone Name
----
(715 -T917
H VAS -Split System
Documentation Author
-%A04
Telephone
Plan Check/Date
-ErLp- rPro
❑❑
15
❑
❑
- -- - - -
Field Check/Date
Compli ce Method
Climate Zone
Source Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
0.14
0.12
0.02
❑❑
Space Cooling
71.94
68.43
3.51
Not Valid for permit
Fans
10.25
10.19
0.06
Domestic Hot Water
0.00
0.00
0.00
applications submitted on or
Pumps
0.00
0.00
0.00
after 01/23/06 because
Totals
82.33
78.74
3.59
Energy Budget is based on
Percent better than Standard:
4.4%
SEER 10.
Building Type:
Single Family
❑ Addition
n/a
❑ Multi Family
❑ Existing + Add/Alt
Building Front
Orientation:
(South)180 deg
Fuel Type:
ft2
Natural Gas
Fenestration:
ft
Number of Dwelling Units:
Area:
53 ft 2
Avg. U: 0.34
Ratio:
13.0% Avg. SHGC: 0.28
BUILDING ZONE INFORMATION
❑❑
Zone Name
----
Floor Area Volume
-- - ' 40 _3,268
H VAS -Split System
---- - -
Total Conditioned Floor Area:
408 ft2
.Existing Floor Area:
n/a
ft2
Raised Floor Area:
0
ft2
Slab on Grade Area:
408
ft2
Average Ceiling Height:
8.0
ft
Number of Dwelling Units:
1.00
F-1
Number of Stories:
1
# of Thermostat Vent
Units Zone Type Type Hgt. Area
100 Conditioned--Sethack- 2 -nla
OPAQUE SURFACES Insulation Act. Gains Condition
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y /
N Status JA IV Reference_ Location_ / Comments
❑ New _02-A11 Whale
Root Wood- x.08_ _0 029- -R-38_ -M-O_ -91-18
/all- Wood 71 -0-102. -RS3- _ LO -0- -31.5-_9.0 IX
Wall Wood 18.0 -0102-R_13_-R_0.0_-225-_9D X
YVall- Wood- 32 -0.102 -R-1.3_ _R_0.0_ 45 90 IX
uu
❑ New 0.9_A3 Whole
❑New -09-A3 Whole
❑ New .09-A3 Whole -_
❑❑
F-1
F1
❑❑
F-1
F-1
❑❑
❑❑
❑❑
❑❑
❑
❑
- -- - - -
uu
❑❑❑❑
❑❑
Run Initiation Time: 11/13/0523:22:35 Run Code: 1131952955
EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY295-1005 Page:3 of 9
Certificate Of Compliance: Residential (Part 2 Of 3) CF=1 R
MR. & MRS. ROGER SCHLESINGER 11/13/2005
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments
.L Window Left (Noodhwest) 53.3 _0.340 -NERC 1028 .NERC _315 _911 New—BETTER BUILT Vinyl Iow-E_ Whole
1. Indicate source either from NFRC or Table 116A. ' 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt.
1 Bug Screen 0.76 6.7 8.0 2.0 0.1 2.0 2.0
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside
Type (sf) (in.) Cap. Cond. R -Val.
Condition
JA IV Reference Status
Location/
Comments
Concrete, Heayyweight 408
PERIMETER LOSSES
Type Length
3.50 28 0_98 0
Insulation
R -Val. Location
26-A1 New
Condition
JA IV Reference Status
Whole / Slab on Grade
Location/
Comments
Slab Perimeter 42
None No Insulation
26-A1 New
Whole
Run Initiation Time: 11113/0523:22:35 Run Code: 1131952955
EnergyPro 4.0 by EnergySoft
User Number: 5553
Job Number: ADY295-1005
Paae:4 of 9
Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R
MR. & MRS. ROGER SCHLESINGER 11/13/2005
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
HVAC Split System Central Furnace 80% AFUE Split Air Conditioner 12.5 SEER New Setback
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R -Value Status Tested?
HVAC Split System Ducted Ducted Attic 8.0 New No
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated' Tank Energy Standby' Tank Insul.
Water Heater # in Input Cap. Condition Factor Loss R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext.
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations.to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct seating, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Documentation Author
Name: ADRIANA I
Title/Firm: SHENASI DESIGN STUDIO Title/Firm: Adriana Gil
Address: 46-045 OCOTILLO DR. #2 Address: 74-854 Velie Way Ste. #8
PALM DESERT, CA 92261 Palm Desert, CA 92260
"I elephone: (760) 779-5996
Lic. #: _ , It,��
(sign re 1 r (irate)
Enforcement Agency
Name:
Title/Firm: .
Address:
Telephone:
Telephone: (760) 404-7917_"
b
11 3 LY
(signs re) (date)
Certificate Of Compliance : Residential (Addendum) CF -1 R
MR: & MRS. ROGER SCHLESINGER 11/13/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified In this checklist. These Items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the
adequacy of the special justification and documentation submitted.Plan Field
Not Valid for permit applications submitted on or after 01/23/06 because Energy Budget is based on SEER 10.
The Roof "R-38 Roof (R.38.2x4.24)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual.
HIGH MASS Design - Verify Thermal Mass: 408 sqft Exposed Slab Floor, 3.50" thick at Whole
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R Plan Field
installation certificate.
I Run Initiation Time: 11/13/05 23:22:35 Kun t;ooe: ii-3iu5zy55 1
I EnerovPro 4.0 by EneravSoft User Number: 5553 Job Number: ADY295-1005 Page:6 of 9
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercedes the items marked with and asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are
shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or Initial applicable boxes when completed or check N/A If not ENFORCE -
applicable. N/A DESIGNER MENT
Building Envelope Measures
ia iou(ay Minimum H-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
u
Ll
u
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
LXI
U
U
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not.
❑
❑X
❑
apply to exterior mass walls).
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
0
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
n
n
n
a. closable metal or glass door covering the entire opening of the firebox
LX_
J
b. outside air intake with damper and control, flue damper and control
❑X
❑
❑
2. No continuous burning gas pilot lights allowed.
Q
❑
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑X
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
R
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑X
❑
❑
permeance rate no greater than 2.0 perm/inch.
❑X
❑
❑
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate tvae and include
n
r,
❑
CF -6R Form:
^.
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
n
(-1
n
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑X _
❑
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
❑X
❑
❑
Coefficient (SHGC), and infiltration certification.
Q
❑
❑
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑X
❑
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑X
❑
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑X
❑
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
0
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
N
El
11having
an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks. or other indirect hot water tanks have R-12 external
n
n
n
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑X
❑
❑
length of recirculating sections of hot water pipes shall be insulated to Table 1508.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑X
❑
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑X
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑X
❑
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
n
(-1
n
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑X
❑
❑
EnergyPro 4.0 by EnergySoft User Number. 5553 Job Number: ADY295-1005
Page:7 of 9
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. NIA DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑X ❑ ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
X❑ ❑ R.
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
❑X ❑ ❑
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
❑X ❑ ❑
reductions in the cross-sectional area of the ducts.
® ❑ ❑
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
® ❑ ❑
duct tapes unless such tape is used in combination with mastic and draw bands.
Q ❑ ❑
4. Exhaust fan systems have back draft or automatic dampers.
® ❑ ❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
® ❑ ❑
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
® ❑ ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
❑ ❑X ❑
7. Flexible ducts cannot have porous inner cores.
® ❑ ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
7 Ryctpm is inMallprt with -
N1 ❑ ❑
a. At least 36" of pipe between filter and heater for future solar heating.
® ❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑X ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑X ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
® ❑ ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
Q ❑ ❑
Lighting Measures
§ 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
X❑ ❑ ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
Q ❑ ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ ❑X ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑X ❑ ❑
OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑ ❑
controlled by an occupant sensor that complies with Section 1`19(d) that does not turn on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑X ❑ ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑X ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
X❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY295-1005
Page:8 of 9
FVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
MR. & MRS. ROGER SCHLESINGER 11/13/2005
SYSTEM NAME FLOOR AREA
HVAC Split System 408
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
32,000
Total Output (Btuh)
32,000
Output (Btuh/sgft)
78.3
Cooling System
Output per System
18,600
Total Output (Btuh)
18,600
Total Output (Tons)
1.5
Total Output (Btuh/sgft)
45.5
Total Output (sgff/Ton)
263.5
Air System
CFM per System
650
Airfiow (cfm)
Airflow (cfm/sgft)
o5u
1.59
Airflow (cfm/Ton)
419.4
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
455
7,943
1,34
117
5,54
0
1,086
607
0
0
0
0
0
0
0
32,000
0
TIME OF SYSTEM PEAK Aug 2 pm
0
1,086
607
10,1161 1 34 6 755
York H4DH018/P4HUA08LO32 U&H I 13.519 2,975
32.000
Total Adjusted System Output
(Adjusted for Peak Design Conditions)
13,519 2,975
32,000
TIME OF SYSTEM PEAK Aug 2 pm
Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0°F 69.1°F 69.10F 115.40F
Air O�
Supply Air Ducts
Outside
0 cfm Supply Fan Heating Coil 114.5 °F,
650 cfm ROOMS
69.1 OF 70.0 °F
11.0 / 77.6 OF
Outside Air
0 cfm
77.6/64.5 °F
h Return Air Ducts 'I
PSYCHROMETRIC
77.6 / 64.5 OF 77.6 / 64.6 OF M 58.0 / 57.0 OF
Supply Fan Cooling Coil
650 cfm
1% Return Air Ducts 4
Supply Air Ducts
59.6 / 57.6 of
52.4% R.H. R007M7S71
76.0 / 64.0 OF