Loading...
0310-128 (AR)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 343335 13 Cy6 CS M.0 ()2!'28/2( batef' �'r Signature of Contractor r OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt'frcim the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.0 for this reason Date _• _Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent to self -insure for workers' compensation, as 'provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STATE FUND Policy No. , 229-14767-2003 (This section need not be completed if the permit valuation is for $100.00 or less). () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions4 Date:. Applicant— Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify, that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. 01 �� a ✓' idr-- Signature (Owner/Agent) ✓ a' Date / - 41 - c-,.7 r, BUILDING PERMIT PERMIT# t 031, 128 DATE I VALUATION TRACT '�,�B.�.CtCb LOT JOB SITE ADDRESS 57, 9&11ICIM''-ACIM APN _ .. OWNER CONTRACTOR/DESIGNER/EN (NEER ROOM SOEW M L C014IMMCTMION 54310 AVENIDA,IUM. 2: IA QTJINTA aA +922$3 07603564.4447 CHU# BC)5I USE OF PERMIT REMIN`1"IAl:.A3'3xlITION' 3500. DE"TACHR11 CA.SITA CUSTOINI CONSTRUCTION 320,N W C4.ARAGUZAItPORT 33.00 Sr EJ'o'.RUW,lJD COST3W.i.•. \sWJL9�1'�SV'. �1Ji',..YEROdV CONSTRUCTION FRE 101!,000-4 18-000 $25$.53 PLAN CHECK FET 101-000-439-318 MEC.RANIC`,6 L FV. 101-000-4E2.M) • $39.50 ELECTIUCAL FEE. iQI.000.420-000 PLilMsYAG FRE '101.000-419.000 $64,50 STRONG MOTION FED -1tFZID l09-x±00"?,41-flflfl $2.52 aKY. -TOTi T, CONTMUCTIQN. D PLAN C(:� - C $609.1s r i QIMS PrRS PA119 F $0100 D NOV 0 4 2003 CITY OF LA FINANCE DEPT... RECEIPT DATE gM y"�- � "� BY �,,,; l DATE F �� INSPE�TgR � INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck .� Exhaust Fans O.K. to Wrap p A, F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wail Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath • Final Final z BLOCKWALL PPROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines - -Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans . O.K for Finish Plaster Sewer Lateral ".Pool Cover Sewer Connection -,.Encapsulation Gas Piping Gas Test Appliances Final Final 7 r_ Utility Notice (Gas) ELECTRICAL APPROVALS , Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) _:COMMENTS: - - ►J v, Bin # City of La Quinta Building & Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 03 o Building Permit Application and Tracking Sheet ProjectAddress: " �-1" �� Oss•ner's Name'. A. P. Number: Address: �� Leeal Description:7�(G-{' �rj� Contractor: Address—.e C;�Q• p� � �j * C�- City. ST, Zip: ' �'„�=�•t_ 1XProject Description: City. ST. zip: Telephone: 54P4 4gf* State Lic. # Arch., Ener., Designer: kil City Lic. #:Al awl u�„� a -9�/ �O ' , c Address: ' f 1 0 1 OU 4 City. ST. Zip: Z5 leo Telephone: ?*0 " 7i%9'"7- `_ - State Lic. #: -..-�.:_-•• - IUlaR Name of Contact Person: i Jwe-.,f 95 e4z— Construction Type: VIQ Occupancy: Project type (circle one): Nes Add'n Alter Repair Demo q. Ft.% © # Stories: # Units: Telephone # of Contact Person: �0 kstimated `� Value of Proiectt rv., 1% APPLICANT: DO NOT VNITE BELOW THIS LINE # Submittal Req'd Rec'd TRAC G PERMIT FEES Plan Sets Plan Check submitted a (0 Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. O� Called Contact Person 31 Plan Check Balance Energy Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan �y 2" Review. ready for corrections ssue kt1 `\ Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading FN HOUSE:- ''' Review, ready for correctio issue !o/a/ Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees y41. RECORDING REQUESTED BY: City of La Quinta Community Development Department La Quinta, CA 92253 WHEN RECORDED PLEASE MAIL TO: City of La Quinta Community Development Department c/o Greg Trousdell P.O. Box 1504 La Quinta, CA 92253 DOC a 2003-792836 10/08/2003 08:00A Fee:37.00 Page 1 of 11 Recorded in Official Records County of Riverside Gary L. Orso Assessor, County Clerk 8 Recorder 1111111111111111111111111111111111111111111111111111111 M S U PAGE SIZE DA PCOR NOCOR SMF MISC. al A I R L COPY LONG REFUND I NCHG COVENANT AND AGREEMENT RESTRICTING THE USE OF THE PROPOSED GUEST HOUSE AT 57-953 INTERLACHEN, LA QUINTA, CALIFORNIA This covenant and agreement is made and executed on this the 25' day of August, 2003, by Roger Stuart Sohn and Francine Beth Sohn for property described herein. The City of La Quinta, a Municipal Corporation, is hereby made a party to this agreement for the purposes set forth below. . The undersigned hereby certifies that they are the property owners of the following described real property in the City of La Quinta, County of Riverside, State of California: Lot 14 of Tract No. 28150 (APN: 762-230-014) in the City of La Duinta, County. of Riverside.` In consideration of the City of La Quinta issuing a building permit for certain improvements which will be constructed on said property, the undersigned does hereby covenant and agree to and with said City. to restrict the use of said property as follows: 1. The detached guest house may not be rented nor sold independent of the main single family residence (Minor Use Permit No. 2003-426); 2. No kitchen or cooking facilities shall.be constructed in the guest house per the provisions of Chapters 9.30.030 (RL Zone District) and 9.60. 100 (Guest Houses) of the La Quinta Municipal Code; and, 3. All on-site facilities are intended for the sole occupancy of the property owner, nonpaying guests, and domestic employees. COVEN426Sohn.WPD/p/greg Page 1 of 3 1 ' a 0 t CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date 11/3/03 La Quinta, CA 92253 No. ' 25163 (760) 771-8515 Owner Roger Sohn Address City Zip Tract # Type Residential Addition Lot # No. Street Unit 1 53953 Interlachen Unit 2 Unit 3 Unit 4 Unit 5 Comments Detached Casita. S.F. 320 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 �4��ZFIEDSc�o cS�1�i�U�' o Q BERMUDA DUNES RANCHO MIRAGE (� INDIAN WELLS PALM DESERT y V LA QUINTA INDIO Q O APN # 762-230-014 Jurisdiction La Quinta Permit # 0310-128 Study Area No. of Units 1 Lot # No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE, This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 320 S.F. or $684.80 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Money Order - Downey Savings - Marvin Jordan Check No. 3494540947 Name on the check Telephone 760/564-4447 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by SyraNn MCGllvrqy Payment Recd 1 Q/% ( _ $684.80 Over/Under Signature li rY v NOTICE: PursuEtoGover!nmentCode Section 66020(d)(1), this will se to notify you that the 90 -day approval period in which you may protest the fees or NOTICE: Pursu other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 August 25, 2003 Mr. Michael Swartz 81-106 Highway 1 1 1, Suite 4H Indio, California. 92201 SUBJECT: - MINOR USE PERMIT 2003-426 (USE COVENANT) Dear Mr. Swartz: (7 60) 777-7000 FAX (760) .777-71.01 The Community Development Department has reviewed your request to construct a detached casitas building of 350 square feet at -'57-953 Interlachen, pursuant to Sections 9.60.100 (Guesthouses) and 9.210.020 (Minor Use Permits) of the Zoning Code. This Department has approved the accessory unit request because it is architecturally compatible with the main residence, subject to execution and recordation of the attached Covenant. Once recorded, please send a copy of the material to our office and the Building and Safety Department. Enclosed is a letter addressed to the County Recorder stating that Covenant can be recorded. Findings in support of the request are: 1. No impact to the City's General Plan will occur as the Land Use Element designates the site for residential purposes under the Low Density Residential category. The existing 10,018 square foot lot (Lot 14 of Tr. 28150) is a legal. lot of record .which can support the detached facilities, provided development standards as set forth in the City's Zoning Code can be met. 2. The lot, measuring 70 feet wide by 148 feet long, currently is developed with a 2,101 sq. ft. single family house (Plan 1 AR) and. two car garage. The proposed casitas has been designed in compliance with the requirements -of Section 9.60.100 of the City's Zoning Code which permits detached bedrooms, subject to final approval by the PGA West Homeowner's Association. Enclosed is a copy of our Zoning Code provisions. As planned, the guest unit is compatible with the design of the main unit and the surrounding neighborhood in terms of landscaping, scale, height, bulk, lot coverage arid exterior appearance, and will be constructed to meet current Uniform Building Code MUP426Guest Unit.wpd/g/greg 113 requirements. A building permit must be issued to constructed the planned improvements. 2. The project is exempt from the provisions of the California Environmental Quality Act (CEQA) under Section 15301(e) which allows additions to existing structures. 3. Infrastructure improvements exist to service the project, subject to the rules and regulations of :the affected public utility companies being complied with during any on-site,construction'activities. No adverse impacts should occur based on approval of this permit. Should you have any questions, please contact me at (760) 777-7067, or via e-mail at gtrousde@la-quinta.org. Sincerely, C7 Y DEVELOPMENT DIRECTOR T DELL 'As ocia PI nner GT. Enclosures c: Com ity Development Director andall, B&S Counter Technician MUP426Guest Unit.wpd P.O. Box 1504 78-495 CALLS TAMPICO (760) 777-7000 LA QUINTA,. CALIFORNIA 92253 FAX (760) 777-7101 August 25, 2003 County Recorder County of Riverside P.O. Box 751 Riverside, California 92502-0751 SUBJECT: RECORDING OF MUP 2003-426 Dear Colleague: The City of La Quinta has approved the above noted Minor. Use Permit. Please allow its recording as presented by the applicant. Should you have any questions, please call me at (760) 777-7067. Very truly ZGJ.ERMAN DEVELOPMENT DIRECTOR OUS ELL�Pla ner GT. LtMUP425 Countympd-g RECORDING REQUESTED BY: City of La Quinta Community Development Department La Quinta, CA 92253 WHEN RECORDED PLEASE MAIL TO: City of La Quinta Community Development Department c/o Greg Trousdell P.O. Box 1504 La Quinta, CA 92253 COVENANT AND AGREEMENT RESTRICTING THE USE OF THE PROPOSED GUEST HOUSE AT 57-953 INTERLACHEN, LA QUINTA, CALIFORNIA This.covenant and agreement is made and executed on this the 25`h day of August, 2003, by Roger Stuart Sohn and Francine Beth Sohn for property described herein. The City of La Quinta, a Municipal Corporation, is hereby made a party to this agreement for the purposes set forth below. The undersigned hereby certifies that they are the property owners of the following described real property in the City of La Quinta, County of Riverside, State. of California: Lot 14 of Tract No. 28150 (APN: 762=230-014) in the City of La Quinta, County of Riverside. In consideration of the City of La Quinta issuing a building permit for certain improvements which will be constructed on said property, the undersigned does hereby covenant and agree to and with said City. to restrict the use of said property as follows: 1. The detached guest house may not be rented nor sold independent of the main single family residence (Minor Use Permit No. 2003-426); 2. No -kitchen or cooking facilities shall be constructed in the guest house per the provisions of Chapters 9.30.030 (RL Zone District) and 9.60.100 (Guest Houses) of the La Quinta Municipal Code; and, 3. All on-site facilities are intended for the sole occupancy of the property owner, nonpaying guests, and domestic .employees. COVEN426Sohn.WPD/p/greg Page 1 of 3 This covenant and agreement shall run with the land and shall be binding upon future owners, their successors, heirs, or assigns, and ourselves, and shall continue in effect while said accessory building remains on the real property or unless otherwise released by the authority of the City, of La -Quinta. All. leases of said dwelling and/or property shall be subject to this restriction. This agreement. shall be entitled to the remedy of injunctive relief in addition of. any remedy in law or equity. This covenant and agreement and the provisions hereof are irrevocable and nonmodifiable except by the written consent of all parties to the agreement, including the City of La Quinta, a municipal corporation. The City shall have the right to enforce each and every provision hereof and the parties agree that the agreement shall not be rescinded, revoked, modified, or otherwise amended or changed, without the expressed written consent of the City first being obtained. In the event that the owners, their heirs, assigns or successors in interest, shall fail to perform any obligation Hereunder, they hereby agree.to pay all costs and expenses incurred by the City of La Quinta in securing performance of such obligation, including attorney's fees. Dated: By: Roger Stuart Sohn By: Francine Beth Sohn Notary COVEMMSohn.WPD/p/greg Page 2 of 3 By: 1/ Oscar Cffci, Planning Manager City of La Quinta COVEN426Sohn. WPD/p/greg Page 3 of 3 State of California County of Riverside On August 29, 2003 before me, Regenia Hensley Notary Public, personally appeared OSCAR ORCI , personally known to me to be the person whose name is subscribed to the within instrument and acknowledged to me that he executed the same in his authorized capacity, and that by his signature on the instrument the person or the entity upon behalf .of. which the person acted, executed the instrument. WITNESS my hand and official seal. (Seal) REGENIA HENSLEY Commission # 1774458 Z z - y Notary Public - California ¢- Riverside County My Comm- Eames Aug 19,2M4 Document Description: Covenant and Agreement Restricting the' Useof the Proposed Guest House at 57-953 Interlachen La Quinta California r TITLE 24 Energy Conservation Standards Compliance Report SOHN GUEST HOUSE 57-953 INTERLACHEN PGA WEST CC - LA QUINTA August 6, 2003 • Job Number: 23705A Designer's Name: MICHAEL SWARTZ, ARCHITECT PMB # 14 81-106* HIGHWAY 111, 1 SUITE 4H INDIO, CA 92201 760-342-7867 Madlin' CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE D•3 _0 3 BY� enterprises ♦♦♦®v♦v Catherine M. Madlin, Certified Energy Analyst Post Office Box 1443 • Palm Springs, CA 92263 760-322-5004 / 323-3644 (fax) E-mail: CMadlin@aol.com Madlin s enterpfises Catherine M. Madlin, Certified Enemy Analyst . 760-322-5004 / 323-3644 (fax) ....... Title 24 Energy Conservation Standards Compliance Report This proposed project has been reviewed for compliance with the 2001 State of California Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design described in this compliance portfolio is in conformance with .the standards as outlined in the attached compliance forms and documentation. i Date: August 6, 2003 Job Number: 23705A Designer's Name: MICHAEL SWARTZ, ARCHITECT Owner's Name: FR.ANCINE & ROGER SOHN Project.Name: SOHN DETACHED GUEST HOUSE Project Location: 57-953 INTERLACHEN - PGA WEST CC - LA QUINTA Method of Compliance: MICROPAS V6.1 CERTIFIED COMPUTER PROGRAM Orientation Of Entry: G.H. ENTRY DOORS FACE WEST Certified Energy Analy�t Catherine M. ?viadlin NR 98-90-544 r r r r R 98-90.144 CABEC Caiitornio Association of Building Energy Consultants • Post Office Box 1443 v Palm Springs, Ca 92263 v Madlin's enterprises Catherine M. Madlin, Certified Energy v Analyst 7 760-322-5004 / 323-3644 (fax) ....... 1; ;. ............. . ............... %%%..%.. -%................ ' ' "' - ' *:i':'� .:: *% " :::;::.;:CMES���.Y,: V.1Yl:l . . . Job Name SOHN GUEST HOUSE Job No. / File No. 23705A Method of Compliance Micropas V6.1 Computer Simulation Total Conditioned Square Footage 320 Sq.Ft. Total Glazing % (Floor/Glass Area Ratio) 20.3% Insulation: Roof / Ceiling R-38 with Radiant Barrier at Roof Insulation: Walls R-21 Batts - 2x6 Wood Studs Insulation: Floor - Slab on Grade None Required Insulation: H.V.A.C. Ducts/Location/Testing R-4.2 / Attic / No Duct Testing Required Glazing U -Value / Type: Fixed 0.55, Dual Pane, Low E2, Aluminum Frame (NFRC Tested Value) Glazing U -Value / Type: French Doors 0.40, Dual Pane, Low E2, Wood Frame (NFRC Tested Value) Glazing U -Value / Type: Glass Block 0.57 (CEC Default Value) Glazing Solar Heat Gain Coefficient (Uncoated) Clear Glazing: 0.35 French Doors / 0.40 Fixed Glazing: Exterior Shading Overhangs As Shown Thermal Mass Square Footage & % Required H.V.A.C. System Type FGGasHeating / ElectricCooling HVAC System Efficiencies (heating/cooling) AFUE / 12.0 SEER Domestic Hot Water Heater (1) 40 Gal. Gas Energy Factor / Eff. / Standby Loss 0.58 or better R12 Blanket on Tank No Recirculating Pump for DHW No Other Requirements Applicable Mandatory Measures v Post Office Box 1443 v Palm Springs, Ca 92263 v Madli s enterprises Catherine M. Madlin, Certified Enemy Analyst v 760-322-5004 / 323-3644 (fax) v Title 24 Compliance Forms CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15:32:42 Project Address........ 57-953 INTERLACHEN ******* --------------------- Building Front Orientation. Front Facing 270 deg (W) PGA WEST - LA QUINTA *v6.01* 1 Documentation Author... CATHERINE M. MADLIN ******* Building Permit U- Interior Madlin's Enterprises Slab On Grade Orientation f - - - - - - -------------- Glazing Percentage......... P.O. Box 1443 Plan Check Date 0.46 Btu/hr-sf-F Palm Springs, CA 92262 Average Glazing SHGC....... 0.44 ' Climate Zone........... 760-322-5004 15 Field Check/ --------------------- Date Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 ---------------- Program -FORM CF -1R ' Wall � User#-MP0207 User-Madlin's ------------------------------------------------------------------------------- Enterprises Run -PERMIT CALCULATION Wood R-11 R-27 GENERAL INFORMATION t Conditioned Floor Area..... 320 sf Building Type .............. Single Family Detached I Construction Type.. New Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Stories.. ...... 1 U- Interior Floor Construction Type.... Slab On Grade Orientation f - - - - - - -------------- Glazing Percentage......... 20.3 % of floor area Factor SHGC Shading ------ Average Glazing U -factor... 0.46 Btu/hr-sf-F t Average Glazing SHGC....... 0.44 -� Average Ceiling Height..... 8 ft ---- ----- Yes BUILDING SHELL INSULATION Component ------------------------- Frame Cavity Sheathing Total Assembly Type ------------ Type R -value R -value --------------- R -value U -factor Location/Comments ' Wall -------- Wood R-21 R-0 -------------- ------------------------ R-21 0.059 RoofRadiant Wood R-11 R-27 R-38 0.025 SlabEdge None R-0 R-0 F2=0.760 FENESTRATION i------------ Over-.;. Area U- Interior Exterior hang/ Orientation f - - - - - - -------------- (sf) ----- Factor SHGC Shading ------ Shading Fins Door Door Front (W) 40.0 ------ --------------- 0.400 0.350 Standard -------------- Standard ---- ----- Yes Window Back (E) 8.0 0.570 0.670 Standard Standard Yes Window Back (E) 8.0 0.570 0.670 Standard Standard Yes Window Right (S) 9.0 0.550 0.400 Standard Standard None ! lA SLAB SURFACES ------------- Area Slab Type (sf) Standard Slab 320 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R ---------------- Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15.32.42 (-MICROPAS6v601 File -23705A1 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION ---- - ------------------------------------------------------------ HVAC SYSTEMS Refrigerant g Tested ACCA ' Equipment Minimum Charge and Duct Duct Duct Manual Thermostat ---Type Efficiency Airflow Location R -value Leakage D Type --------------------------------------------------- ------ ---------- 1 Furnace 0.780 AFUE n/a Attic R-4.2 No No Setback ACSplit 12.00 SEER No Attic R-4.2 No No Setback WATER HEATING SYSTEMS --------------------- Number Tank External j in Energy Size Insulation # Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- ------------------- -------------- ------ ---------- Storage Gas. Standard 1 0.58 40 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------- *** *** Items in this section should be documented on the plans, *** in to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Radiant Barrier. The radiant barrier must have F an emissivity less than or equal to.0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. REMARKS The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. r The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determing the HVAC design loads and equipment selection(s). The HVAC design shall be done in accord- ance with industry standards. The load calculation in this report considers ambient temperature load, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment.performance. i` The installing glazing contractor shall provide the required CF -6R Installation Certificate with installed glazing values i and areas. The installing hvac contractor shall provide the required CF -6R with. -the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title........... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15:32:42 MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION ------------------------------------------------------------------------------- REMARKS The installed plumber shall provide the required CF -6R listing the water heater model number(s) and certified plumbing fixtures. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single -building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name.... MICHAEL SWARTZ Company. ARCHITECT Address. PMB 14 81106 HWY 111 4H INDIO, CA 92201 Phone... 760-342-7 7 License. Signed.. O g!�O?7 (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... CATHERINE M. MADLIN Company. Madlin's Enterprises Address. P.O. Box 1443 Palm Springs, CA 92262 Phone... 760-322-5004 Signed.. `G2� (date)— 8-1 a3 Certified Energy Analyst Catherine M. Ma4in NR 98-90-544 r r r R 98-94-144 CA®Ee Confornia Association of Building Energy Convibaft MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15:32.42 Project Address........ 57-953 INTERLACHEN ******* _____________________ PGA WEST - LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ----------------- MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin s Enterprises Run -PERMIT CALCULATION ----------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed ` on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- *150(a): Minimum R-19 ceiling insulation. -150(b): Loose.fill insulation manufacturer's labeled R -Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply ' t Design- Enforce- er ment _V o exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned tspaces designed to limit air leakage. ,2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ' 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150on1: Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec.. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control C. Flue damper and control*, 2. No continuous burning gas pilots allowed. V- -W-10, MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15.32.42 MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -FORM MF-1R --------User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION ---------------------------------------------------------=------------ SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES --------------------------------------------------------------- Design- Enforce - 110 -113: HVAC equipment, water heaters, showerheads and er ment faucets certified by the Commission. 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ✓ 150(1): Setback thermostat on all applicable heating and/or cooling systems. 150(j): Pipe and Tank insulation i 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. ✓ *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sectons 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic; tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4.inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber addhesive duct tapes unless such tape is used in combination with mastic and drawbands. i2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At'least 36 inches of pipe between filter and heater i for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF-1R Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15:32:42 MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -FORM MF-1R --------User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION --------------------------------------------------------------- pilot light (Exception: Non -electrical cooking appliances ✓ with pilot < 150 Btu/hr). LIGHTING MEASURES ----------------- 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. Design- Enforce- er ment COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15:32:42 Project Address........ 57-953 INTERLACHEN ******* _____________________ PGA WEST = LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit ' Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field -Check/ Date Climate Zone.. . ... 15 ____ ------------- Compliance Method.. ..... MICROPAS6 v6.01 for 2001 Standards by Enercomp,-Inc.--- MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION ------------ --------------- ------------ ------------ -------------------- --------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design Design i=--------------------------------- Margin = ---------- E = Space Heating.......... 3.56 2.60 ---------- _ 0.96 = _ Space Cooling.......... 69.26 77.20 -7.94 = = Water Heating.......... 56.01 48.86 7.15 = --------------- = Total 128.83 128.66 ------- = 0.17 _ *** Building complies with Computer Performance GENERAL INFORMATION ------------- -------------------- Conditioned'Floor Area..... 320 sf Residence x320 2560 Building Type .............. Single Family Detached Construction Type ......... New No Building Front Orientation. Front Facing 270 deg (W) Number of'Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 2560 cf 320 sf 20.3 % of floor area 0.46 Btu/hr-sf-F 0.44 8 ft BUILDING ZONE INFORMATION Floor # of Vent Vent Air Area Volume Zone Type (sf) (cf) Dwell Cond- Thermostat Units itioned Height Area Leakage ---- ------------ Type ----- (ft) (sf) Credit 1.ZONE ------------------ ------------- --------- Residence x320 2560 1.00 Yes Setback 2.0 Standard No COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15.32.42 MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -FORM C-2R User#_MP0207 User-Madlin s Enterprises Run -PERMIT CALCULATION -------- ----------------------------------------------------------------- OPAQUE SURFACES FENESTRATION SURFACES Orientation ---------------------- ---Window-- Area (sf) ----- --------------- SHGC Act Azm Tilt Exterior Shade Type/SHGC Interior Shade Type/SHGC Area U- Insul Act Solar Form 3 Location/ Surface -------------- (sf) ------ factor R-val Azm Tilt Gains Reference Comments 1.ZONE 0.400 ----- ----- --- ---- ----- ------------ ---------------- 1 Wall 88 0.059 21 270 90 Yes W.21.2X6.16 2 Wall 160 0.059 21 0 90 Yes W.21.2X6.16 3 Wall 112 0.059 21 90 90 Yes W.21.2X6.16 4 Wall 151 0.059 21 180 90 Yes W.21.,2X6.16 5 RoofRadiant 320 0.025 38 n/a 0 Yes R.38.2X4.24 n/a n/a n/a PERIMETER LOSSES SLAB SURFACES Length ---------------- F2 Insul Solar Surface ------------ ------ (ft) Factor R-val Gains Location/Comments 1.ZONE -------- ------- ----- ---------------------- 6 S1abEdge 72 0.760 R-0 No FENESTRATION SURFACES Orientation ---------------------- ---Window-- Area (sf) ----- U- factor ----- SHGC Act Azm Tilt Exterior Shade Type/SHGC Interior Shade Type/SHGC ` 1.ZONE Left Rght ----- --- ---- -------------- -------------- 1 Door Front (W) `40.0 0.400 0.350 270 90 Standard/0.76 Standard/0.68 2 Window Back (E) 8.0 0.570 0.670 90 90 Standard/0.76 Standard/0.68 3 Window Back (E) 8.0 0.570 0.670 90 90 Standard/0.76 Standard/0.68 4 Window Right (S) 9.0 0.550 0.400 180 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) ----- Wdth ----- Hgth ----- Dpth Hght Ext Ext ---- ---- Ext Dpth Hght Ext Dpth Hght 1.ZONE -------- ---- ---- ---- ____ ' 1 Door 40.0 6 6.67 2 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 8.0 2 4 1.5 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 8.0 2 4 1.5 0.5 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ 1.ZONE Standard Slab 320 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15.32.42 MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION --------------------------------------------------------------------------------- System Type ------------- 1.ZONE Furnace ACSplit Tank Type ------------ 1 Storage HVAC SYSTEMS ------------ Refrigerant Tested Minimum Charge and Duct Duct Duct Efficiency Airflow Location R -value Leakage --- ------- ------------- ------- --------- 0.780 AFUE n/a Attic R-4.*2 No 12.00 SEER No Attic R-4.2 No WATER HEATING SYSTEMS --------------------- Number in Energy Heater Type Distribution Type System Factor ------------------------ ------ -------- Gas Standard 1 0.58 ACCA Manual Duct D Eff No 0.743 No 0.637 Tank External Size Insulation (gal) R -value ------ 40 ---------- R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS I--------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. REMARKS The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determing the HVAC design loads and equipment selection(s). The HVAC design shall be done in accord- ance with industry standards. The load calculation in this report considers ambient temperature load, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing glazing contractor shall provide the required CF -6R Installation Certificate with installed glazing values and areas. The installing hvac contractor shall provide the required CF -6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15.32.42 MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -FORM C-2R -User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION ------- ---------------------------------------------------------------------- REMARKS The installed plumber shall provide the required CF -6R listing the water heater model number(s) and certified plumbing fixtures. Madlin s enteipfises Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) .... O H V.A. C. Load Calculation HVAC SIZING Page 1 HVAC Project Title........... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15.32.42 Project Address........ 57-953 INTERLACHEN ******* --------------------- Glazing Solar .................... PGA WEST - LA QUINTA *v6.01* 1352 InternalGain .................... Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises n/a ' ----------- P.O. Box 1443 6626 Plan Check Date Palm Springs, CA 92262 1 760-322-5004 FielT­CHe_cR7 Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. __________________________ MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- . Floor Area ................ 320 sf Volume.. ........... 2560 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ PALM DESERT Latitude... .. ....... 33.7 degrees winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. .. ..... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Cooling (Btuh) 1176 1022 2289 895 450 583 6415 1283 7699 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Description --------------------------------- (Btuh) Opaque Conduction and Solar...... ----------- 3529 Glazing Conduction ............... 1143 Glazing Solar .................... n/a N Infiltration ..................... 1352 InternalGain .................... n/a tDucts. ... ................... Sensible Load .................... 602 6626 LatentLoad ...................... n/a ' ----------- Minimum Total Load 6626 Cooling (Btuh) 1176 1022 2289 895 450 583 6415 1283 7699 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15:32:42 MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -HVAC SIZING -User#-MP0207 ------- --------------------------------------------------------------------- User-Madlin's Enterprises Run -PERMIT CALCULATION HEATING LOAD CALCULATIONS DESIGN CONDITIONS FOR 7 --------------- ZONE '1.ZONE': WINTER DESIGN TEMPERATURES: InsideTemperature ................................ OutsideTemperature 70.0 F ............................... 32.0 F DESIGN TEMPERATURE DIFFERENCES Standard....... 38.0 F CONDUCTIVE HEAT LOSS: U -factor Heat Area (Btu/hr- TD Loss Description ----------------- Orientation ----------- (sf) sf-F) (F) (Btuh) Wall West ----�- 88.0 x --�---------�- 0.0592 x --------- 38.0 198 Wall North 160.0 x 0.0592 x 38.0 = 360 Wall East 112.0 x 0.0592 x 38.0 = 252 Wall South 151.0 x 0.0592 x 38.0 = 340 Shaded Wall n/a 320.0 x 0.0247 x 38.0 = 300 S1abEdge n/a 72.0 x 0.7600 x 38.0 = 2079 CONDUCTIVE TOTALS FOR OPAQUE SURFACES 3529 Double Door West 40.-0 x 0.4000 x 38.0 = 608 Double Window East 8.0 x 0.5700 x 38.0 = 173 Double Window East 8.0 x 0.5700 x 38.0 = 173 Double Window South 9.0 x 0.5500 x 38.0 = 188 CONDUCTIVE TOTALS FOR GLAZING SURFACES 1143 INFILTRATION: (Type: Medium) 2560 cuft x 0.77 ac/hr x 0.018'Btu/cuft-F x 38.0 = 1352 SUBTOTAL 6024 DUCT HEAT LOSS: Duct Location: Attic 0.10 x 6024 = 602 TOTAL HEATING LOAD: 6626 HVAC SIZING Page 3 HVAC Project Title........... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15:32:42 MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -HVAC SIZING --------User#_MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION ----------------- ------------------------------------- ------- COOLING LOAD CALCULATIONS DESIGN CONDITIONS FOR ZONE '1.ZONE': Shading Heat ' i Description -------------- Orientation ------------- SUMMER DESIGN CONDITIONS: Coeff. SCapprox Gain (Btuh) Double Door ------ West ---- 40.0 x 73 InsideTemperature ................................ Outside Temperature 1219 Double Window 78.0 F x 0.799 = ..............................112.0 TemperatureRange ......................... Double Window East 34.0 F F 467 Double Window South - ......... x 0.477 = 137 DESIGN EQUIVALENT TEMPERATURE DIFFERENCES SOLAR TOTAL (Sext) 2289 INFILTRATION: (Type: Medium) Standard. ............................... FrameWalls andDoors 34.0 F 2560 cuft x ............................. FramePartitions...... Btu/cuft-F 32.6 24.0 F INTERNAL GAIN (Ig): 1.00 x ( .......................... + 0) = 450 F Dwelling Units CONDUCTIVE HEAT GAIN: Appliance -------- U -factor Heat SUBTOTAL 5832 Area (Btu/hr- TDeq Gain Description ------------------------- Orientation ----------- (sf) sf-F) (F) (Btuh) Wall West ------ 88.0 x ------- ------- 0.0592 x 32.6 = ------- 170 Wall North 160.0 x 0.0592 x 32.6 = 309 Wall East 112.0 x 0.0592 x 32.6 = 216 Wall South 151.0 x 0.0592 x 32.6 = 291 .Shaded Wall n/a 320.0 x 0.0247 x 24.0 = 190 CONDUCTIVE TOTALS FOR OPAQUE SURFACES 1176 Double Door West 40.0 x 0.4000 x 34.0 = 544 Double Window East 8.0 x 0.5700 x 34.0 = 155 Double Window East 8.0 x 0.5700 x 34.0 = 155 Double Window South 9.0 x 0.5500 x 34.0 = 168 CONDUCTIVE TOTAL FOR GLAZING SURFACES 1022 SOLAR HEAT GAIN: Note: SCapprox = SHGC / 0.87 Shading Heat ' i Description -------------- Orientation ------------- Area (sf) SHGF Coeff. SCapprox Gain (Btuh) Double Door ------ West ---- 40.0 x 73 ---------------- x 0.417 1219 Double Window East 8.0 x 73 x 0.799 = 467 Double Window East 8.0 x 73 x 0.799 = 467 Double Window South - 9.0 x 32 x 0.477 = 137 EXTERIOR SOLAR TOTAL (Sext) 2289 INFILTRATION: (Type: Medium) 2560 cuft x 0.57 ac/hr x 0.018 Btu/cuft-F x 34.0 = 895 INTERNAL GAIN (Ig): 1.00 x ( 2 x 225.0 + 0) = 450 Dwelling Units People Appliance -------- SUBTOTAL 5832 HVAC SIZING Page 4 HVAC Project Title.......... SWARTZ.SOHN.G.HOUSE Date..08/06/03 15:32:42 MICROPAS6 v6.01 File -23705A1 Wth-CTZ15S92 Program -HVAC SIZING --------User#-MP0207 User-Madlin s Enterprises Run -PERMIT CALCULATION ------------ --------------- ------------ ------------ -------------------- DUCT,HEAT'GAIN: Duct Location: Attic 0.10 x 5832 = 583 TOTAL HOURLY SENSIBLE HEAT GAIN 6415 LATENT LOAD: 0.20 x 6415 = 1283 4 ' TOTAL COOLING LOAD 7699 Madlin's enterpfises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) .► .... VV Addendums and Notes x Madlin -s enterprises Catherine,M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) ....... Title 24 Building Energy Efficiency Standards Residential Manual Excerpt RADIANT BARRIERS Introduction A radiant barri heat. Aluminu Installation of although they of radiant material. season, The Commission has approved an energy credit for radiant barriers meeting specific eligibility and installation criteria. The radiant barrier energy credit is an adjustment to the ceiling U -value when the ceiling is adjacent to an attic with a radiant barrier. The credit is automatically applied by modeling a radiant barrier in an approved computer program with this optional capability. Construction Below are the parameters for receiving credit for a radiant barrier, including criteria for the installation, ventilation and material, all of which contribute to the performance of the radiant barrier. Installation Installation must be in conformance with ASTM C-1158-97 (Standard Practice for Use and Installation of Radiant Barrier Systems (RBS) in Building Construction.), ASTM C-727- 90(1996)el (Standard Practice for Installation and Use of Reflective Insulation in Building Constrctins.), ASTM C-�1.313-975 (Standard Specification for Sheet radiant Barriers for Buildi g �Construction Appliations), and ASTM C-1224-99 (StarF�rd Specification for Reflective Insu i for Bji ding A plications a¢q�radiant barrier must.be securely i stalled in a erman n 7an�, r W t th s i ide irig o t d t a is oo g-th Radia t bars er uS�n e i tall d�to e o f tr ss xa� rs I K / ( p c ods n nyfolng mr�thnris wifi o m� crime 1. Draped over the truss/rafter ( the top chord) before the upper roof deck is installed. 2. Spanning between the truss/rafters (top chords) and secured (stapled) to each side. 3. Secured (stapled) to the bottom surface of the truss/rafter (top chord). A minimum air space must be maintained between the top surface of the radiant barrier and roof decking of not less than 1.5 inches at the center of the truss/rafter span. • P.O. Box 1443 v Palm Springs, Ca 92263-1443 v E-mail. Cmadlin@aol.com v N Madlin's Enterprises — Addendums & Notes 4. Attached [laminated] directly to the underside of the roof decking. The radiant barrier must be laminated and perforated by the manufacturer to allow moisture/vapor transfer through the roof deck. The radiant barrier must be installed to cover all gable end walls and other vertical surfaces in the attic. Ventilation The attic mus 1. Conform t 2. Provide a each 150 t bel1A `�n� tJifa ed to: � o ni f t rer' 'rrstrrict'oyrts. /> X1.1 �r}} fr44e entalatipp rea o n t les4a[pnlesquarefoot f ent area for s tare ee>lof attic- loor e 3. Provide no less than 30 percent upper vents. (Ridge vents or gable'end vents are recommended to achieve the best performance. The material should be cut to allow for full airflow to the venting.) The radiant barrier (except for radiant barriers laminated directly to the roof deck) must be installed to: 1. Have a minimum gap of 3.5 inches between the bottom of the radiant barrier and the top of the ceiling insulation to allow ventilation air to flow between the roof decking and the top 'surface of the radiant barrier. 2. Have a minimum of six (6) inches (measured horizontally) left at the roof peak to allow hot air to escape from the air space between the roof decking and the top surface of the radiant barrier. When installed in enclosed rafter spaces where ceilings are applied directly to the underside of roof rafters—_a_ minimum ai space of 1 inch must be provided between the radiant barrier and the to th f e ceiling insulation, and ventilation must be providedyor each rafter space. Vents must a proved -a# b h th 6,Pper-andjo7 s onefl os f a e aft Y ac . 0 Emiss i I I • The emissivity of the radiant barrier must b less than or equal to 0.05as tested in accordance with ASTM C-1371-98 or AS -E408-7(1996)ei. • The product must meet all requirements for California certified insulation material [radiant barriers] of the Department of Consumer Affairs, Bureau of Home Furnishings and Thermal Insulation. Madlin's Enterprises — Addendums & Notes Note: Aluminum will deteriorate or corrode in the presence of alkaline materials. Unless the aluminum foil is protected by waterproofed paper or plastic coating, keep it from coming into direct contact with anything alkaline, such as masonry surfaces. Inspection If a radiant barrier was used for compliance credit, check the installation guidelines provided above for the builder. Especially critical are the ventilation and air space requirements that enable the radiant barrier to perform as expected. o . CEC Title 24 e9i a ial esig� Manual 001-Colde-- Figure 3-2: M�thbds r nsta aat f r R is t rr er I `I U U y Roof Decking Roof Decking Air Space ,: Rafter Air Space Rafter Radiant Radiant Barrier Barrier Insulation Insulation Joist a4 Joistr�s`��a' ? Sin`4 �'��te.� .+� -7✓r-�+�--1 4 �. 5.`Sa �t} �. iS� rte+ Method 1: Radiant Barrier Draped Method 2: Radiant Barrier Attached Over Top of Truss/Rafter Between Truss/Rafters Roof Decking Roof Decking Air Space Rafter Rafter Radiant > Radiant Barrier Barrier g . Insulation yQ Insulation Joist Joist fh Method 3: Radiant Barrier Attached to Method 4: Radiant Barrer Attached to Bottom of Truss/Rafter Underside of Roof Deck