Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14-0704 (RPL)
P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 6/04/14 Application Number: 14-00000704 Owner: Property Address: 81790 LA PAZ CT BEER MICHAEL & ELIZABETH APN: 764-280-999-96 -300237- Property Zoning: MEDIUM HIGH DENSITY RES Application valuation: 40000 Contractor: I Applicant: Architect or Engineer: BUBBLE SPRINGS tD P.O. BOX 1046 J RANCHO MIRAGE, CA 92270 E �� ��t1� (760)341-2336 _ L.*41AA4ft"4L Lic. No.: 728796 CITY 0F I -A CtUINTA ------------------ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: C53 D35 License No.: 728796 Date: G S� Contractor. O -BUILDER DECLARATION I hereby affirm under penalty of perjury that I empt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business' t fessions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale3. (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY _ 1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT r s ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor . Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EVEREST NATL Policy Number 76001635 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code hall forthwiJW-c_orrhpIy with those provisions. ADate�` If Applicant: WARNING: FAILURE TO SECU WORKERS' CONSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTI AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. , APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as. a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for.180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building const ru ion, and hereby authorize representatives of this county /to enter upon the above-mentioned property forurposes. Dat��l Signature (Applicant or Agent): 4 t Application Number . . . . . 14-00000704 Permit POOL 2013 Additional desc . Permit Fee . . . . 178.75 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 12/01/14 Qty Unit Charge Per Extension 1.00 178.7500 EA MISC POOL/SPA 178.75 ---------------------------------------------------------------------------- Special Notes and Comments POOL AND SPA AT REAR YARD (DENISE POELTLER ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2013 CALIFORNIA BUILDING CODE. June 4, 2014 4:01:50 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 PLAN CHECK, POOL 97.24 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 178.75 .00 .00 178.75 Plan Check Total .00 .00 .00 .00 Other Fee Total 99.24 .00 .00 99.24 Grand Total 277.99 .00 .00 277.99 LQPERMIT i q9 Trilogy at La Quinta 60-750 Trilogy Pkwy La Quinta, CA 92253 Ph: 760-777-6059 Fax: 760-777-1620 Tuesday, May 27, 2014 MICHAEL A. BEER TRUSTEE / ELIZABETH J. BEER TRUSTEE RE: Design Review Modification Conditionally Approved 81790 La Paz Ct / Customer ID #: TRLAQ-0937-02 Dear Michael A. Beer Trustee / Elizabeth J. Beer Trustee: Trilogy, Trilogy at La Qainta ]Maintenance association We are pleased to inform you that your plans for installation of an attached patio cover, barbecue kitchen island, pooVspa, landscape restoration/new and removing an existing wall in order to complete your project received on May 20, 2014, have been approved by the Design Review Committee with the following conditions: 1, 2, 3, 7, 8, 9, 11, 12, 13,15, 17 and 19 (see attached copy). Please note: Any damages caused by contractors due to construction must be repaired; all irrigation and landscape shall be restored to the original condition . This approval does not constitute consent by the Association for the applicant to encroach, trespass, or build on any property other than that of the applicant. This approval is related solely to the items reserved for approval by the CC&R's in accordance with the Design Review Guidelines. The approval does not extend to the quality of work done by your architect, or contractor, or to any structural engineering, soils engineering, or site grading and drainage design. You are urged to obtain the services of a state licensed professional for consultation as needed. The Design Review Committee is composed of volunteers. As such, it does not review applications to ensure compliance with building codes, or other local or state laws. Please be advised that this approval does not relieve you from obtaining any necessary building permits from the governmental agencies involved to ensure compliance with these codes. Any violations of these ordinances will be your responsibility to correct. Thank you for your patience in this matter and for complying with the Association's policies and standards. Sincerely, For the Design Review Committee, Mirna Hernandez Asst Manager On -Site Property Enclosures cc: Board of Directors Design Review Committee TRILOGY AT LA QUINTA H.O.: La CONDITIONS OF APPROVAL Property Address: WITq 0 0062 Z C�— Date Reviewed: 114, Conditions of Approval Your plans have Been approved, provided plat you meet die Renis checked below and all work is consistent whin till' Design Guidelines. 1 The patio cover material must be Alumna wood or other similar wood like construction. Roofing materials shall match the roof matenal of the dwelling or be open wood lattice 2 The color of the patio cover matches the home's stucco, accent, Cascia or white. / 3 Any patio cover or awning to be installed and attached to the home must be installed in such a manner that it does not compromise the integrity of the water permeability of die home. 4 Due to die patio covers size it must be constructed with variable heights or must be constructed in two sections with a separation in between 5 The size of the patio cover is limited to the size of die proposed patio slab. 6 1home. Tile proposed retractable awning may not be a striped awning. It must be a neutral color that blends with die Please submit a sample of die fabric. 7 Obtain services of a state licensed professional for consultation. / $ (:)btain necessary building pen -nits from die city of La Quints, meeting setback requirements per city code and maintain the existing drainage. g Maintain positive drainage in accordance with die Trilogy Design Guideliues (Section 3.8). 10 The screen door must be die color of the house stucco or be black. ✓ 11 Tf—u—tiZe—rground drain is installed, , he drain needs to terminate Jii the grass swale au be flush With Llic Luri ah ca ned with a pop -u drain cover. 12 Pool, spa, fountain, and air cothditioning equipment setbacks must comply with City ofTa Quints codes. All equipment shall be located, screened, or recessed in a mannerso as to not be viewable from any lot or street and die noise from die equipment attenuated for die adjacent property owners. Pool set backs are (i" for hardscape sill 18" for water line. 13 The color of the proposed concrete is natural or a neutral tone. 14 Rear yard may not exceed 70% lhardscape and must have a minimum of 309 sof'tscape, measured from die rear building face of' wall to the side property lines. 15 Proposed planting meets with the Trilogy Rear Yard Minimum Plaiting Requirements standards and all plants are included on die Revised Approved Plant List contained in die Design Guidelines. 16 The proposed wall or iron work to match the existing developer retaining wall in material, style and color or shall be die Frazee Paint color specified in the guidelines. 17 Replace block wall perShea Homes swidard block wall specification, if removing any portion of block wall to gain access to rear or side yard (requires inspection of rebar:before cap is installed). 18 Refer to Exhibit "F" ui die Design Guidelines. (Block Wall Design). X 19 1Wlien work is completed, please submit Notice of Completion form attached. 20 Make sure rear yard property line pias (markers) remain during construction (applies to golf course lots only) 21 All contractors must meet the Association representative prior to commencuhg construction. 22 Resubmit showing drainage flow/plans. 23 See notes on plans (if any) 24 Ain independent irrigation controller must be used for die rear yard, it cuuhot be tied into die front yard. Notes wAs,s aTimaTev" al L7 CHITECn RALIDRC Fdms%Caiatiats of Amoral 1 POOL SPECS SIZE: 40' X 20' X 15' DEPTH: 3.5' TO 5.0' SQFT: 636 SQ.FT. PERIMETER: 120' TILE: TO BE SELECTED INTERIOR MATERIAL: PEBBLE PLASTER NOTES: SWIMOUT WITH UMBRELLA SLEEVE -SPA SPECS SIZE: TX 7' DEPTH: 3.5' RAISED HEIGHT: -0- SQFT: 49 SQ.FT. PERIMETER: 28' TILE: TO BE SELECTED INTERIOR MATERIAL: PEBBLE PLASTER SPILLWAY: TILE TO MATCH WATERLINE NOTES: DECK SPECS DECK TYPE: STAMPED CONCRETE TOTAL DECK SQFT: 1084 SQ. FT. NOTES: FINISHES PLASTER Tropics Blue w/o Abalone DECK TYPE: Stamped DECK COLOR: San Diego Buff w/ Walnut TILE: Martinique Royal Blue 2" x 2" on spillway with Martinique Royal Blue Border at waterline THREE AERATOR LINES POOL: -0- ELEVATION WITH TILE AT WATERLINE AND PEBBLE PLASTER WITH TWO LED LIGHTS SWIMOUT WITH UMBRELLA SLEEVE NOTE: ALL DRAINAGE TO FOLLOW EXISTING PRECISE GRADING PLAN LAWN 5.0' WD CITY C)F"� C�t�IN�A FINAL 5/27/2014 BUILDING & SAFE T Y DEPT. RECEIVED APPROVED . FOR CONSTRUCTION ^ b ���� BY� MAY 2.8 2014 CIS' OF LA DATE j W *A QUINTA COMMUNITY DEVELOPMENT SPA: -0- ELEVATION WITH TILE SPILLEDGE, TILE AT WATERLINE AND PEBBLE PLASTER; INCLUDES 6 FLUSH MOUNTED YP �, HYDROTHERAPY JETS AND ONE LED LIGHT 21' 3.5' WD J N 19' WD 101 3" 1 1 l i ............= .. 13 EXISTING COVERED I EQUIPMENT LOCATION I PLANTING AREA EXISTING COVERED EXISTING WATER FEATURE PROVIDE GAS, WATER, DRAIN LINE, AND ELECTRIC FUTURES FOR BBQ LAWN 000.�°�4, o� N O a dv U w � 0@) 0 ate., �. t4:10mo o4 .P, 04 V'T ��fn ©N 0 ®Oz ®1 N CL 0 00 U °W o o J 0 00 m a B 0- 00 M d C N V V C N ^ .3 �3 4Q t0 re Or C* ^r- IB E Scale: Bin. # City of La Quinta Bul d w 8t Safety Division P.O. Box 1504,78-495 Cage Tampico 4.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # ^ D ` 1� Project Address: Owner's Name:. A. P. Number. Address: -6 cA. % C a v v�- Legal Description:{� Contractor: ) J%r City. $T, Zip: � 0. J to-, 1 rte, Cc,-— (� t ' L '•.''".iCr„q(},•i+'; ':S: : Telephone: &[ Address: P U . 6ax m,/6", Project Description: City, ST, Zip:2Z�lJ Telephone: r' State Lia #: 7Z g 6, Arch., Engr., Designer: N CityLic. g: Address: City, ST, Zip: Telephone: State Lic. #: Name of Contact Person: .�' .." :. Construction Type:. Occupancy: Project type (circle one): ew Add'a Alter Repair Demo Sq. FL: # Stories: T# Units: Telephone # of Contact Person: 7W ". Estimated Value of Project Q APPLICANT: DO NOT WRITE BELOW THIS UNE N Submittal Pian Sets Rcq'd 'Rec'd TRACKING PERMIT FEES PIan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit. Truss C21cs. Called Contact Person Plan Check Balance. Title 24 Cales. Pians picked up Construction Flood plain plan Plans resubmitted Mecharilcal Grading plan r, Rtdcw, ready for correctiouslissue Electrical Subeontactor List Called Contact Pawn erPlu�-biug Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for correctionsfissue ODeveloper Impact Fee Planning Approval Called Contact Person (� AXP,P. Pub. Wks. Appr Date of permit Issue School Fees Total Permit Fees 1014 1tioiq — -Lo Use