Loading...
BSPN2015-003278-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BSPN2015-0032 Property Address: 56218 PLATINUM WY APN: 775220021 Application Description: SIGNATURE / CALL WEST / GENERATOR FOR SALES OFFICE Property Zoning: R6 RL -1516 Application Valuation: $2,500.00 Applicant: CALIFORNIA WEST CONSTRUCTION I 5927 PRIESTLY DRIVE STE 110 CARLSBAD, CA 92008 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B. C10, D31 License No.: 980589 Date: I 1 ) S' Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the ` basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Add VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/11/2015 Owner: RREF II CWC LAQ LLC 5927 PRIESTLY DR S CARLSBAD, CA 920 n � O '� � Contractor: R BRAY LLC DBA R6 RL -1516 1210 1210 N RED GUM tns ANAHEIM, CA 92 a (714)507.-1881 Llc. No.: 980589 WORKERS COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. l Date: � I / � t Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above• mentioned property for inspection purposes. • 1 � Date: $ Signature (Applicant or A Description: SIGNATURE / CALL WEST / GENERATOR FOR SALES OFFICE CONDITIONS Type: SPECIAL INSPECTION Subtype: Status: UNDER REVIEW Applied: 8/11/2015 SKH Approved: Parcel No: 775220021 Site Address: 56218 PLATINUM WY LA QUINTA,CA 92253 Subdivision: Block: Lot: 56 Issued: Lot Scl Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $2,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 5927 PRIESTLY DRIVE CARLSBAD Details: SPECIAL INSPECTION -GENERATOR FOR SALES OFFICE AND MODELS. 2013 CALIFORNIA BUILDING CODES. CHRONOLOGY CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT CALIFORNIA WEST CONSTRUCTION 1 5927 PRIESTLY DRIVE CARLSBAD CA 92008 (760)918-6768 LBELLOSO@CALWESTC STE 110 OMMUNITIES.COM CONTRACTOR S R BRAY LLC DBA POWER PLUS 1210 N RED GUM ANAHEIM CA -92806 (760)918-6768 STREET OWNER RREF 11 CWC LAQ LLC "5927 PRIESTLY DR STE CARLSBAD CA' 92008 (760)918-6768 110 Printed: Tuesday, August 11, 2015 1:44:56 PM 1 of 2 ��U L SYSTEti1S 0 1 FINAL=* I BLD BOND INFORMATION ATTACHMENTS Printed: Tuesday, August 11, 2015 1:44:56 PM 2 of 2 SYS TENTS Bin City of La Quinta . Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico - La Quinta, CA 92253 (760) 777-7012 Building Permit Application and Tracking Sheet Permit # —2,PVO Project Address: Owner's Name: + w" 3?4(A. ' t -j -P -Q } A. P. Number: CM i k.e._ P j V -e r) Ger Legal Description: e.cc4or' Pprrh,�- f�°r h(40(v„$' Qty�, 9bZo3 / ST. 21Y P(a i'i ren, way Contractor: 0 Wo S Telephone: 5 Rq .................:........................... Address: 2 -71 S - p 0.- [t er n'S (; Lv CI Project Description: City, ST, Zip: - P.e,, GA a2S? ��O -�� P► -I �? pr-c—�I0. �-o f S Telephone: CLS -11- -4 Z0 P S' s � o W t NL�O `I d:a� State Lic. # : q City Lic. #•: -�y nt, p� r ori e O e n rL Arch., Engr., Designer: Address: City., ST, Zip: Telephone: Construction TY -t ancY Type: Occupancy: •1 State L ic. #• Project tYPa (circle ne • New Add'n Alter Repair Demo Name of Contact Person: LQ C� Art✓i eI Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: 016-)- 25-5- -4Z4>T Estimated Value of Project: $ 5000 APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Gradin plan Grading P � 2°a Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed ' Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- ''d Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 3-6 Tyr W Tvr)e W Portable Power Cable Type W Industrial Grade Single and Multiconductor Portable Round Power Cable 2000 Volt: SO°C (-40eC). Oil and Sunlight Resistant. Single Conductors Listed as Type RHH/RHW-2. UL and c(UL) Listed. CSA Certified. MSHA Approved. RoHS Compliant. APPLICATIONS Type W Portable Power Cable is suitable for use in Industrial and light-to-medium.mining applications, heavy-duty service and temporary as power supply cables. Motor, battery and generator leads. It is also used for mobile and portable electrical equipment. SPECIFICATIONS • UL Listed - Type W per UL 1650 • Conductors are manufactured in accordance with ASTM and B-172 • Made in accordance with ICEA S-75-381 • NEMA WC -58 - Portable and Power Feeder Cables for Use in Mines and Similar Locations • MSHA accepted, P-136-135, LR65300 • UL Listed as Type RHH or RHW-2 • CSA or c(UL) Certi=fied as applicable • RoHS Compliant • Meets FT -5 Flame Test • Copyright 2010. Southwire Company. Mt.*,/� 501��LWTCC MADE SA All Rights Reserved. . One Southwire Drive *USA IN +TCRoHS Complia fit °Southwire is a registered trademark Carrollton, Ga. 30119 USA �. (,I of Southwire Company. Wed Aug 08 09:27:36 EDT 2012 Paae 1 of 4 Type W Portable Power Cable CONSTRUCTION Southwire Type W portable power cables are manufactured with rope -lay stranded, bunched members, annealed copper conductors. A polyester or paper tape separates the copper conductors from the EP rubber insulation. The insulated conductors are assembled round with fillers as needed. The cable is covered with a black CPE rubber jacket. Jackets are reinforced by a braid or serve of synthetic material.. Sizes 8 AWG through 500 MCM fully annealed stranded bare. copper per ASTM B-172. I WEIGHTS, MEASUREMENTS AND PACKAGING NUMBER OF COND. AWG OR KCMIL COND. STRAND NOMINAL INSULATION THICKNESS NOMINAL OVERALL DIAMETER CURRENT AMPS* APPROX. NET WEIGHT LBS/M'** INCHES mm INCHES mm 1 CONDUCTOR - TYPE W - 2000 VOLT 1 8 168 0.060 1.52 0.490 11.18 80 160 1 6 266 0.060 1.52 0.535 13.59 105 220 1 4 420. 0.060 . . 1.52. 0.595 ..15.11.. 140 290. 1 !2 651 0.060 1.52 0.645 16.38 190 395 1 1 840 0.080 2.03 0.695 17.65 220 490 1 1/0 1064 0.080 2.03 0.770 19.56 260 575 1 2/0 1311 0.080 2.03 0.800 20.32 300 700 1 3/0 1653 0.080 2.03 0.860 21.84 350 820 1 4/0 2090 0.080 2.03 0.925 23.49 405 1000 1 250 627 0.095 2.41 1.045 26.54 455 1170 1 350 855 0.095 2.41 1.145 29.1 570 1520 1 500 1235 0.095 1 2.41 1.310 33.28 700 2090 2 CONDUCTOR - TYPE W - 2000 VOLT 2 8 71 0.060 1.52 0.820 20.83 74 365 2 6 49 0.060 1.52 0.930 23.62 99 515 2- 4 105 0.060 1.52 1.050 26.67 130 730 2 2 168 0.080 1.52 1.245 31.62 174 1000 2 1 210 0.080 2.03 1.420 36.07 202 1490 2 1/0 259 0.080 2.03 1.515 38.48 234 1710 2 2/0 259 0.080 2.03 1.575 40.00 271 1880 2 3/0 420 0.080 2.03 1.685 42.80 313 2420 2 4/0 532 0.080 2.03 1.845 46.86 361 2940 A!,� t' Copyright 2010. Sotrthwlre Company. 1>*z C All Rights Rcscrvotl. � outhw a MADE 1 U IN *THE SH` RoHS Compliant I �u'Southwire is a registcrcd trademark One Southwire Drive ©L c A p ..} 4,' (� P y. Carrollton, Ga. 30119 USA J us, of Southwire Company. r Wed Aua 08 09:27:36 EDT 2012 Page 2 of 4 Type W Portable Power Cable �w 3 CONDUCTOR - TYPE W - 2000 VOLT 3 8' 71 0.060 1.52 0.930 23.62 65 525 3 6 49 0.060 1.52 1.015 25.78 87 660 3 4 '105 0.060 1.52 1.130 28.70 114 900 3 2 168 0.080 1.52 1.320 ' . 33.53 152 1300 3 1 210 0.080 2.03 1.475 37.47 177 1600 3 1/0 259 0.080 2.03 1.605 40.77 205 2280 3 2/0 259 0.080 2.03 1.680 42.67 237 2680 3 3/0 420 0.080 2.03 1.825 46.36 274 3220 3 4/0* 532 0.080 2.03 1.950 49.53 316 3900 3 250* 608 0.095 2.41 2.275 .57.78 352 .5070 3 350* 855 0.095 2.41 2.425 61.59 433 6570 3 500* 1235 0.095 2.41 2.845 72.26 536 8700 Multiconductor cables are UL and C(UL) unless marked. *UL Listed only 4 CONDUCTOR - TYPE W - 2000 VOLT 4 8 11 -71 0.060 1.52 1.010 25.65 65 620 4 6 49 0.060 1.52 1.105 28.07 87 825 4 4 105 0.060 1.52 1.245 31.62 114 1175 4 2 168 0.060 1.52 1.465 37.21 152 1650 4 1 210 0.080 2.03 1.625 41.27 177 2450 4 1/0 259 0.080 2.03 1.755 44.58 205 2570 4 2/0 259 0.080 2.03 1.875 47.62 237 3450 4 3/0* 420 0.080 2.03 1.905 48.39 274 4050 '4 4/0* 532 0.080 2.03 2.175 55.24 316 4970 4 350* 855 0.095 2.41 2.684 68.18 394 6312 Multiconductor cables are UL and C(UL) unless marked. *UL Listed only 5.CONDUCTOR - TYPE W - 2000 VOLT 5 8 71 0.060 1.52 1.070 27.18 52 710 5 6 49 0.060 1.52 1.210 30.73 69 1010 5 4 105 0.060 1.52 1.400 35.56 91 1400 5 2 168 0.060 1.52 1.605 40.77 121 2340 5 1 : 210 0.080 2.03 1.890 48.01 141 3040 Copyright 2010. Southwire Company. Southwire e t MADE �� <7's All Rights Rcscrvcd. �1 grCCfl(��Ki C'.� e One Southwire Drive I IN ++THE $� RoHS Compliant FF�� %outhwire Is a registered trademark Carrollton, Ga. 30119 USA j . USA �t � us. 01 Southwire Company. r Weri Ann ris (14'97'RF, FIST ?r119 ' Pane 3 of A Tyge VV Portable Power Cable 5 1/0 259 0:080 2.03- 2.010 51.05 164 3460 5 2/0* 259 0.080 2.03 2.075 52.70 189 4180 5 3/0* 420 0.080 2.03 2.260 55.50 219 4900 5 4/0' 532 0.080 2.03 2.425 61.59 252 5980 Multiconductor cables are UL and C(UL) unless Marked. *UL Listed only. --f-OF CO.Q(TOZi COLORSEQUENCE 2 i:BIIA(K WHIR' 3 B 1 LAA (K, WHITE, GREEK 0 G. 4 IB (K,AVHIITFj cRFErlt RED l 0.0 5 BIA(KINK GRURP RK OMAGE *Ampacities based on 90°C Conductor and W G Ambient temperature per table 400.5(6) of the 2011 National Eletrical Code® **Actual Shipping weight may vary! W. Copyright 2010. Southwire Company. All Right Resc:mod. 1 thwire'. Sou .E nQ One Southwire Drive USA R<.3 -14S Compliant %oulhwire is a registered trademark Carrollton, Ga. 30119 USA us of Sourhwire Company. %A/.,i A— nJq nQ-97-ir, r=nT gn19 Parip 4 of 4 r 000, N When it comes to innovation in mobile power generation, Doosan Portable Power leads the industry in providing features you can count on to meet the demands of critical applications in the harshest conditions. Strong powertrains you can depend on • Robust and fuel efficient engines ensure maximum uptime and low cost of ownership • Leroy-Somer alternators feature AREP excitation to give unmatched performance in motor starting and voltage stability Rugged, reliable, and environmentally friendly • Units are built with an integrated fuel cell and feature the toughest running gear components for safe and trouble -free towing, on- or off -road • Heavy-duty skids with forklift slots for stability and easy mobility • The enclosure is built from heavy -gauge steel and finished with a 13-stage powder coat process to provide the ultimate corrosion protection • Doosan brings to market the only mobile generator line that includes 110%- fluid containment as a standard feature on all models Safe and easy connections and maintenance _ • Routine maintenance is easier and safer because the battery, filters, and fill points are on the curb -side of the generator • The operator is always informed and in control of the generator with easy -to -ready analogue gauges, a user-friendly main controller • Redesigned connection panel provides safe and easy wiring connections with bare end or terminated cables plus. An array of twist -lock, GFCI receptacles, and optional camlock panel simplify connections • Three -position voltage selector switch is standard on all models up to the G185 and equipped with a protection scheme that prevents operators from changing voltage during operation ■ Dedicated 60OV-30 generators available on the G240, G290, G450, and G570 models • Remote start/stop capability for standby applications Widdel j 44 Tar G345WJD T3>: 4MV-30, O� @ 24OV-361, 0., @ 208V-30, 0. q,?40V-10, 1. @ 120V-10, 1. @ 600V-30, 0. Voltage Conhgu Frequ-,enqy.Cap Lim& My-, � 31 Engine Make /Model 06werbutp6t 60660 Emissions Tier Level Fuel Tank capacity.- uu Runtime @ 100% Load IRAN , MEMINNE-00 3 f� (33 �,.7)-' 144.4 Q66 8) 15*5.8(3957). 465�8 (4212) 165.8.(4Z12) Width - in (mm) (1511) .67(1702) Mitsubishi'54Q24362 Mitsubishi S4S-Y,362 John Deere 4045TF285E (kWm) 31 (23)- 42 (31.3) 90 (67) 83. (2" 1.23) Tier 4 -interim Tier 4 -interim Tier 3 Amps* k W kVA Amps kW kVA* Amps kW kVA- *Amps kW kVA Amps kW kVA 8PF,.60Hz 30 20 215 28 .35 87 58 73. 113 94 94 173 11.5 144 8PF,'OHZ 20 -2 5 1, 84 -j8 - 5 174 ..58 73 :22.6 '94.' 94 346 115 144 8PF, 60H:-; ..69 20 25 97 28 35 201 58 73 236 85 85 368 106 133- 4 Wire' 00F, i561-12, '28 20- -'20 - 39. 28 j8 -81. 58 58 94�' - 6.8. 68 :147 .:16*6 106 Zig-Zag 65 15.6 15.6 89 21 21 188 45 45 .221. 53. 53 346 83 83 4 Wire'. Si S 20, OPF, 60H2-) '20,' 78 28 .28 161-, .58 -58 189. '68 68., . -:294 106 :106 Zig Zag 65x2 15.6 15.6 89-x2 21 21 188x2 45 45 1 221-21 53 1 53 1 346x2 83 83 8PF,60Hz'I, �_:567:1,-�, 408'.. 408 458 110 110 ration 3 -Position Switch 4 Wire. @ 120V-16, 1.OPF, 6011z 3 -Position Switch i4�,-. `110 3 -Position Switch 3 -Position Switch 3-Position'Switch .�408 .408* ability...,, '-':60HZ-Ohl* . 1 6(z Only 60Hz Only 0HZ O'ty . 60Hz'Only 0.9PF, 60Hz Lim& My-, � 31 Engine Make /Model 06werbutp6t 60660 Emissions Tier Level Fuel Tank capacity.- uu Runtime @ 100% Load IRAN , MEMINNE-00 3 f� (33 �,.7)-' 144.4 Q66 8) 15*5.8(3957). 465�8 (4212) 165.8.(4Z12) Width - in (mm) (1511) .67(1702) Mitsubishi'54Q24362 Mitsubishi S4S-Y,362 John Deere 4045TF285E (kWm) 31 (23)- 42 (31.3) 90 (67) 83. (2" 1.23) Tier 4 -interim Tier 4 -interim Tier 3 3508 (1591) 5260 (2386) 47 (178) 91.9.(j47-9) H;1 18.9� 18.2 21 U. M John Deere 4045H F285 John Deere 4045HF485 179 (13-4) M(13.4). Tier 3 Tier 3 -171.6 (049.6). 171.16(649.6)'- 22..3 19.8 Len n (m rim) ith 3 f� (33 �,.7)-' 144.4 Q66 8) 15*5.8(3957). 465�8 (4212) 165.8.(4Z12) Width - in (mm) (1511) .67(1702) 68.7 (1745) 71.7(1820) 71.7(1820) `Height'- in:(mrn) 5414 (405) -,68:(1727)-, .82.4 (2093) - 83. (2" 1.23) 83;6 (212 3) Weight (Ready to Run) - [b ft-) 2588 (1174) 3508 (1591) 5260 (2386) 6466 (2933) 7220 (3275) Sou n*d Levet @ 2.3'ft ('7m) aiid 100% Load dB(A):.' 6G 66 68 68* 18.5 A PAWI�@�' �7�R-K� 0_ V 'Dedicated generator 60Hi Only COUSIN I'll II Ila Mae= RIMP-0 M-11, H M; IN Amps k.W kVA ''Amps kW; A m ps. kW kVA Amps p . --kW Amps kVA @,48OV-30, 0.8PF, 60Hz P. 220. 146 183. ..kVA 287 191 239 349 .232 290 549 365 456 ..kW 686 456 570' @ 240V=30, 0!8PF, 60H'Z 439 146 1:83- 5,74 121. 239'. 698r ..'232- 290 .109.8 365- -456 1371 456 570 @ 208V-30, 0.8PF, 60Hz, 500 144 180 607 175 219 805 232 290 1259 363 454 1416 -408 510 io 4Wire I.OPF, 60Hz @ 240V-•Zig-zag 2001 144,: � -144 243', 75 322. 232 .232 504 3.63 1, �_:567:1,-�, 408'.. 408 458 110 110 4 Wire. @ 120V-16, 1.OPF, 6011z 66� J44 i4�,-. `110 86: 7.1133... 644 ?32. 2 3 3. 363 .�408 .408* Zig-zag 58X2 1 0.9PF, 60Hz 279 •.448. 4.66 539 `448' ,:,,5610.. Voltage Configuration 3 -Position Switch Link Board Link Board Link Board Link Board F.r.eq-ueni;y,Capabili*ty "66Hz Only 60Hi Only 5OHz/60Hz Switchable 60Hz Only 6OHz Only Engine Make/ Model John D Power Output @ 180ORPM "HP 'kWn).- Emissions Tier Level Fuel 'Tank Capacity, Gal (Q Runtime @ 100% Load - Hr �Ml ,�I:E) [TH _IR ftEl .......... - ...... ......N!I i 1, axe M ME _0 sere 6068HF285 John Deere 6068HF485 Cummins QSL9-G3 Cummins QSX1 5-G9 Cummins QSXi 5-G9 ?16 (161), 286 (21.4). 352 (262) 5414 (405) 680' (507) Tier 3 Tier 3 Tier 3 Tier 2 Tier.2 .3..7,,(960:4) 254 (9605) '3861(1461.2) .574 (2173) . 574 (2173) 23.2 19 21 22.2 18.5 �Ml ,�I:E) [TH _IR ftEl - i 1, axe Length- in(mO .264 (5179) 203.9151 N- -221 . (56 1.1) ..260.9 (6627) 260.9-( . 6627) Width - in (mm) 75.7 (1923) 75.7 (1923) 77.7 (1974) 85.9(2182) 85.9 (2182) H&ig,h(,:in (mm). 94.8 (2408) 94..8 (2408) 111.4'(2830) 139.8'(3,043). 119,9 (3043) Weight (Ready to Run) - lb (kg). 9166 (4158) 9678 (4390) 11957 (5424) 18271 (8288) 18573(842S) Sound L . evel Qc �, f(7m)'.and 1001Lo6d dB(A) 68. -69 70 74 76 VB_E 3',F,�ffTg,S7 C *Dedicated 6 Tundra Package' keeps the machine warm and running with uncompromising performance. • For reliable performance down to-40`F/°C, the Coolant Heater, Oil Pan Heater, Battery Charger and Heater Pad, and Heated Breather Hose provide the ultimate solution' *The combination of these parts will change depending on the generator model Improve your generator's autonomy with any of these options • Positive air shut-off valve (Rodo Deaco`') • Oil level maintainer • Remote fuel valves • Tundra PackageT'i. • LoJack'-' Roda Deaco is a registered trademark of Roda Deaco valve. Inc. LoJack is a registered trademark of LoJack corporation Experience Doosan Portable Power and our industry -leading support and service. Whatever the job, we have the solution. From our comprehensive range of air compressors, lighting systems and generators to our rugged and reliable light compaction equipment, we have a solution to fit your needs. Running a successful business takes more than powerful equipment. That's why Doosan Portable Power partners with an experienced global dealer network to stand beside you every step of the way. Doosan Portable Power — more than 100 years of providing excellence. Prsuc h.emtrr �cnau�,i,� r LJ746=6SAN Doosan Portable Power 1293 Glenway Drive Statesville, NC 28625 aoosanPortab[ePower.com ,,3) J1,C. simInfracorc,'ortabicf'o%v. r-'LE-0 1"-100-1' Ile .- r l CITY OF LA r' n''1�( DEPT: �- BUILDING & Q'.•`' •r� y FOR CONSiRUC 4� DATE_ J S x s %P S �0 1 v %P 1 I 0o s t s ol ra f 1 r' L