BWFE2016-0176O� aw
78-495 CALLE TAMPICO C� D
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BWFE2016-0176
Property Address: 80450 PLATINUM WY
APN: 775220021
Application Description: ` PARKER RE / BLOCK WALL
Property Zoning:
Application Valuation: $900.00
Applicant:
TESERRA
P 0 BOX 1280
CO^.CHELIA, CA 92236
LICENSED CONTRACTOR'S DECLARATION '
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C-8, C10, C29, C53, C27, D12 License No.: 656128
D� a e v "' � _C� -o^ nt actori— Vie! -P=
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a -
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(
11, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
( ) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
Owner:
PARKER RE
80450 PLATINUM
LA QUINTA, CA 92
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/5/2016
AUG 45 2016
CITY OF LA QUINTA
Contractor: COMMUNITYDEVELOPMENTDEPARTMENT
TESERRA
P 0 BOX 1280
COACHELLA, CA 92236
(760)389-9222 .
Llc. No.: 656128
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
o 1Ae work for which this. permit is issued.
,w,__Jw have and will maintain workers' compensation insurance, as required by
Se tion 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: STARSTONE NATIONAL INSURANCE COMPANY Policy Number:
T10160317
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
PJae:ti —5 — (b Japphcanf:.��
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is correct.
I hereby affirm under penalty of perjury that there is a construction lending agency for I agree to comply with all city and county ordinances and state laws relating to building
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). construction, and -hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Lender's Name:.
"D --ate 5— 3--1 (t Signatue (Applicant orAgent).
Lender's Address:
Date: 8/5/2016 '
Application Number: BWFE2016-0176
Owner:
Property Address: 80450 PLATINUM WY
PARKER RE
APN: 775220021
80450 PLATINUM DWAY
Application Description: PARKER RE / BLOCK WALL
LA QUINTA, CA 92253
Property Zoning:
Application Valuation` $900.00
Applicant:
Contractor:
TESERRA
TESERRA
P 0 BOX 1280
P 0 BOX 1280
COACHELLA; CA 92236
COACHELLA, CA 92236
(760)389-9222
---------------------------------------------------------------------------------------------
Llc. No.: 656128
Detail:,12LF OF 6' GARDEN WALL[CITY SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALCBE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING
WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES.
DESCRIPTION
FINANCIAL INFORMATION
ACCOUNT
QTY
'AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
$1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WALL/FENCE - FIRST 100 LF
101-0000-42404
0
$47.86
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WALL/FENCE - FIRST 100 LF PC
101-0000-42600
0
$60.91
Total Paid for FENCE OR FREESTANDING WALL: $108.77
0•
.77
rBin #
-
Permit #78-495
Project Address: _ —
City of La Quinta
Building R Safety Division
Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Owner's Name: �� Q
A. P. Number:
-...
Address: �0�����r�"h 1/•tM L�:ril
Legal =Descripilon:
City, ST, Zip:
53
Contractor..
Address: _ ��
Project Description: wi,v
City, ST, Zip:
Telephone: Q , 37y --Z
t
State Lie. #: p2
City Lie. 9..-
;Arch.,
Arch.,Engr., Designer:
-
Address:
City, ST, Zip -1_
.
Telephone:
State Lie.
Construction Type: Occupancy:.
Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person
h
Sq. Ft.;
# Stories,
it Units:
Telephone # of Contact Person:
Estimated Value of Project: Ov
'
APPLICANT: DO NOT WRITE BELOW THIS LINE
H
Submittal
Req'd
Reed
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted •
Item
Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cal cs.
Called Contact Person
Plan Check Balance
Title 24 Cates.
Pians picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Gradin Ian
Grading P
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grani Deed
`''
Plans picked up
S.M.I.
II.O.A. Approval
Plans resubmitted
Grading
IN IIOUSF.:-
ReYiew, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
—Schooi'r,ees,
.
—
Total Permit Fees
FOOTING PT[O..N.. "A')
a._ ..... __._.._.
. 1
� F
I
#4 HORIZONTAL REBAR EPA
(USE BOND BOND BEAM BLOCK) i
i
1
(
i
e( 611 OR 8" BLOCK
1
H..
HEIGHT FROM TOP #4 HORIZONTAL AT 32" MAX. O.C. HEIGHT FROM TOP'
OF FOOTING . (USE BOND BEAM BLOCK) 1 OF FOOTING
I
H•: W
DIRECTION OF
j.a_ "W'•
HOOK ON EVERY
j (FOOTING WIDTH)
OTHER REBAR
SEE TABLE "A"
'SEE PAGE 2 FOR ADDITIONAL INFORMATION`
6' 29"
#4 @ 24" O.C.;
SEE TABLE "A"
SEE TABLE "B"
ALTERNATE DESIGNS MAY BE POSSIBLE
WHEN PROVIDED WITH AN • ENGINEERED
OF
FOR REBAR SIZE
FOR REBAR SIZE
IS AT THE USER'S RISK. AND CARRIES 1140
IMPLIED OR INFERRE& GUARANTEE AGAINST'
AND SPACING
AND SPACING
FAX (76O) 777-701 1
(f,C{CAI4 f4COAR IN C`cN1T:R OP Cf:IJ.)
(I.CCA'fE RIAIW; IN CEN li ft OF COJJ
'
:... :..•.. ^. FIN18H GRADE
( 1) #4 REBAR
.....
—a ryt- : a
! � MIMI
5 v1'"`
10' 7�*•' •�'�
�y "ONTINUOUS
>`7I,II
1 Ifit
(I IIS
(2) - #-4- REBAR �£
CONTINUOUS
' .:'€sem.
1�
REVERSE1111111..
H•: W
DIRECTION OF
j.a_ "W'•
HOOK ON EVERY
j (FOOTING WIDTH)
OTHER REBAR
SEE TABLE "A"
N
ALL FOOTINGS ADJACENT TO
SLOPES TO BE AT LEAST 5' TO
DAYLIG14T AS SHOWN BELOW.
H•: W
._VERTICAL _
REINFORCEMENT
3' 17"
##4 @ 48"_O,C::
4' "
#4 @ 48" O.C.
WESTERN RIVE
'SEE PAGE 2 FOR ADDITIONAL INFORMATION`
6' 29"
#4 @ 24" O.C.;
N
ALL FOOTINGS ADJACENT TO
SLOPES TO BE AT LEAST 5' TO
DAYLIG14T AS SHOWN BELOW.
f (FOOTING WIDTH)
SEE TABLE "B'•
i
NQ'rEs: CHECK.-�yITHTyE,B,LILL,(pIN_G__DEPAE2Ttvi�lyTTO.
1') THIS DESIGN DOES NOT ALLOW GRADE VERIFY IF A BUI.:LDI[�IG' P[3MIT IS, REQUIRED._
MORE THAN 6" ON OPPOSING SIDES OFT AEMYOF LA G 7 TARI 1T IS REQUIRED; THE FOLLOWING
NOTA RETAINING WALL. . INSI ECTIONS ARE REQUIRED:
BUILDING & SAF �T�/ (�Em
2) FENCE HEIGHTS ARE REGULATED — CONS LT ZONING —'I j F�3.CT1—- �: E XCAVATION TRENCH CLEAN WITH
REGULATIONS BEFORE' BEGINNING CONS RUCTION. P 1 R O V L INP E AND SUPPORTED 3"'ABOVE AND
3) NO WATER COURSE OR NATURAL DRAINA E SHALP(% CONSTRU A A FROM HE SURROUNDING EARTH/DIRT.
OBSTRUCTED: R/.PR -GROUT; BOND BEAM REBAR AND
4) GROUT ONLYTHE CELLS CONTAINING EBAR. THIS W LL ERTICAL R AR IN PLACE- INSPECTION PRIOR TO
1S NOT DESIGNED FOR ALL CELLS TO BE I�OQ 2p�(q �l/ LACING GROUT.
5) ALL REBAR TO BE ASTM SPEC. A615, GR R GROUT IS PLACED PRIOR TO ANY
CAP PLACEMENT.
o) ALL REBAR LAP SPLICES TO BE 24 MINIMUM.
7) ALL MASONRY UNITS TO BE ASTM C -90 -GRADE N.
8) REBAR TO BE CENTERED IN MASONRY CELLS.
a.
WESTERN RIVE
'SEE PAGE 2 FOR ADDITIONAL INFORMATION`
n
DISCLAIMER;
ALTERNATE DESIGNS MAY BE POSSIBLE
WHEN PROVIDED WITH AN • ENGINEERED
OF
s' Atlh,
FOOTING
IS AT THE USER'S RISK. AND CARRIES 1140
f (FOOTING WIDTH)
SEE TABLE "B'•
i
NQ'rEs: CHECK.-�yITHTyE,B,LILL,(pIN_G__DEPAE2Ttvi�lyTTO.
1') THIS DESIGN DOES NOT ALLOW GRADE VERIFY IF A BUI.:LDI[�IG' P[3MIT IS, REQUIRED._
MORE THAN 6" ON OPPOSING SIDES OFT AEMYOF LA G 7 TARI 1T IS REQUIRED; THE FOLLOWING
NOTA RETAINING WALL. . INSI ECTIONS ARE REQUIRED:
BUILDING & SAF �T�/ (�Em
2) FENCE HEIGHTS ARE REGULATED — CONS LT ZONING —'I j F�3.CT1—- �: E XCAVATION TRENCH CLEAN WITH
REGULATIONS BEFORE' BEGINNING CONS RUCTION. P 1 R O V L INP E AND SUPPORTED 3"'ABOVE AND
3) NO WATER COURSE OR NATURAL DRAINA E SHALP(% CONSTRU A A FROM HE SURROUNDING EARTH/DIRT.
OBSTRUCTED: R/.PR -GROUT; BOND BEAM REBAR AND
4) GROUT ONLYTHE CELLS CONTAINING EBAR. THIS W LL ERTICAL R AR IN PLACE- INSPECTION PRIOR TO
1S NOT DESIGNED FOR ALL CELLS TO BE I�OQ 2p�(q �l/ LACING GROUT.
5) ALL REBAR TO BE ASTM SPEC. A615, GR R GROUT IS PLACED PRIOR TO ANY
CAP PLACEMENT.
o) ALL REBAR LAP SPLICES TO BE 24 MINIMUM.
7) ALL MASONRY UNITS TO BE ASTM C -90 -GRADE N.
8) REBAR TO BE CENTERED IN MASONRY CELLS.
WESTERN RIVE
'SEE PAGE 2 FOR ADDITIONAL INFORMATION`
n
DISCLAIMER;
ALTERNATE DESIGNS MAY BE POSSIBLE
WHEN PROVIDED WITH AN • ENGINEERED
'
ANALYSIS. USE OF THIS STANDARD DESIGN
IS AT THE USER'S RISK. AND CARRIES 1140
IMPLIED OR INFERRE& GUARANTEE AGAINST'
PHONE (760) 777 -7.1,25 -
FAILURE OR DEFECTS.
FAX (76O) 777-701 1
DE COUNTY CODE UNIFORMITY PROGRAM
F'REESTANDIN-Is BLOCK -WALL
95 CALLS, ,AIM I 11
f A.01)LN`1'A, (IA1,.1PORNIA 9225.3
IU/)/2Ulh COMMUI:ITY.DUVELOPAIEWt blifT. P.4CF, 1 UP2
FOO
m
DESIGN PARAMETERS:
ACTIVE SOIL PRESSURE (PSF) =30
PASSIVE SOIL BEARING (PSF) = 150
COEFFICIENT OF FRICTION = 0.25
ALLOWABLE SOIL BEARING (PSF)' =1500
WIND = 80 MPH. EXPOSURE C
SEISMIC:
NA= l.'3. Nv= 1.6. Z=0.4. SOIL PROFILE=So
WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM
TAt�l Ot
r' FREESTANDING BLOCK WALL
PHONE (7 60) 777-7125 78-495 CALLL TAMPI
LA OUINTA. CALIVORNIA
FAX (760) 777-701 1 1 f0/1.)/n014 I commu,4rly UF:VIsI (:1'AfEh"I'twirr.1 PAW: 2 or• 2
m =CO
gF4944i��e