04-3441 (SFD)I
BUILDING & SAFETY DEPARTMENT
P.O. Box 1504 (760) 777-7012
78-495 CALLS TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153
BUILDING PERMIT
Application Number . . . . 04-00003441 Date 4/22/04
Property Address . . . . . . 60749 WHITE SAGE DR
APN: 764-270-999-64 -300231-
Application description 'DWELLING - SINGLE FAMILY DETACHED
Property Zoning . . . . . . LOW DENSITY RESIDENTIAL
Application valuation 214050
Owner
SHEA LA QUINTA
C/O JEFF MCQUEEN
8800 N GAINEY CENTER 350'
SCOTTSDALE AZ 85258
Contractor
SHEA HOMES, INC.
81260 AVENUE 62
LA QUINTA CA 92253
(760) 777-6005
WCC: NTL -UNION INS
WC: 7165833
08/01/04
CSLB: 672285—.06/30/05
CCC: B
------------------
Structure Information ----------
---
'Construction Type
TYPE V - NON RATED
Occupancy Type
DWELLG/LODGING/LONG <=10
Flood Zone . . . . .
. . . NON -AO FLOOD ZONE
Other struct info . .
. . CODE EDITION
2001 CBC
FIRE SPRINKLERS
NO
GARAGE SQ FTG
572.00
PATIO SQ FTG
221.00
NUMBER OF UNITS
1.00
FIRST FLOOR SQ FTG
2474.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
Permit Fee
1042.00 Plan Check Fee
677.30
Issue Date
Valuation . .
. . 214050
Qty Unit Charge
Per
Extension
BASE FEE
639.50
115.00 3.5000
----------
THOU BLDG 100,001-500,000
402.50
-----------
Permit . . . . . .
----- -----
MECHANICAL
- --
Additional desc
Permit Fee . . . .
93.00 Plan Check Fee
23.25
Issue Date . . . .
Valuation-
0
Qty Unit Charge.
Per
Extension
P.O. BOX 1504• �� VOICE (760) 777-7012
78-495 CALLS TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: 44-3441 1 Date: `i - ZZ -o Y
Applicant:
Archit c r E ine r
—z)
Archit ct or E ineer' dress=
�LI`z�U 1-bVe I
Lic. No.: (f24`7 6 t
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisionnls(of `Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and ms Licensi in full force and effect.
Class ct
License Date
t-1 )2;L)5�---6onIJ
OWNER -BUILDER DECLARATION
hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5. Business and Professions Code: Any
city or county Ihat requires a pem* to construct, alter, improve, demolish, or repair any stniclure, prior to its issuance, also requires the appticant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she Is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than rive hundred dollars (;500).):
U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, howevec, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or site did not build or improve for the purpose of safe-
) -U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044. Business and Professions Code: The Contractors'
State License Law does not apply b an owner of property who builds or improves thereon, and who contracts for the projecls with a contractor(s) licensed pursuant to
We Contractors' State License Law.).
U I am exempt under Sec. . BA P.C. for this reason
WORKERS' COMPENSATION DECLARATION
'I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to seff4nsure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the perfomrance of the work for which this permit Is
issu My wakgrrr'immponsation insurence canter and polM.y number are:
I certify that in lite perronnance of Ute work for which fhis permrt isis issued, I s II not employ any person in any manner 6o as to become subject to the workers'
compensation laws of Caliiomia, acrd agree 1ha ff I should become subject tD tite workers' compensation provisions of Section 3700 of Ute Labor Code,1 shall
Date'f �Jcomply with those provisions.
1 plicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lenders Name
Lenders Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application Is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
Issued as a result of Ibis application, the owner, and the applicant, each agrees to. and shall, defend, indemnify and hold harmless the City of La Oulnta, its
officers, agents and employees for any act or omission related to the work being performed under or fotloWng issuance of this perrnit.
2. Any permit issued as a result of this application becomes null and void it work is not commenced within 180 days from dale of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above informatio Is Correct. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of (his county to a ter the above-mentioned property for inspection purposes.
�Ij -.—�.
Date 1 rSalure (Applicant or Agent)
Page
2
Application
Number
04-00003441 Date
4/22/04
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
1.00
9.0000
EA
MECH FURNACE <=100K
9.00
1.00
11.0000
EA
MECH FURNACE >100K
11.00
1.00
9.0000
EA
MECH B/C <=3HP/100K BTU
9.00
1.00
16.5000
EA
MECH B/C >3-15HP/>100K-500KBTU
16.50
4.00
6.5000
EA
MECH VENT FAN
26.00
1.00
6.5000
EA
MECH EXHAUST HOOD
6.50
----------------------------------------------------------------------------
Permit
ELEC-NEW RESIDENTIAL
Additional
desc . .
Permit Fee
215.99
Plan Check Fee
54.00
Issue Date
. . . .
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
2474.00
.0350
ELEC NEW RES - 1 OR 2 FAMILY
86.59
5720.00
.0200
ELEC GARAGE OR NON-RESIDENTIAL
114.40
----------------------------------------------------------------------------------
Permit .
. . . . .
PLUMBING
Additional
desc . .
Permit Fee
171.00
Plan Check Fee
42.75
Issue Date
. . . .
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
17.00
6.0000
EA
PLB FIXTURE
102.00
1.00
15.0000
EA
PLB BUILDING SEWER
15.00
1.00
7.5000
EA
PLB WATER HEATER/VENT
7.50
1.00
3.0000
EA
PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB LAWN SPRINKLER SYSTEM
9.00
6.00
.7500
EA
PLB GAS PIPE >=5
4.50
1.00
15.0000
EA
PLB GAS METER
15.00
----------------------------------------------------------------------------
Permit .
. . . . .
GRADING PERMIT
Additional
desc . .
Permit Fee
. . . .
15.00 Plan Check Fee
.00
Issue Date
. . . .
Valuation
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
FA
.• J
Page 3
Application Number
. . . . .
04-00003441
Date
4/22/04
----------------------------------------------------------------------------
Special Notes and Comments
SFD LOT 64 PLAN 5210A.
PERMIT
DOES
NOT
INCLUDE BLOCK WALL,
POOL, SPA
OR
DRIVEWAY APPROACH.
Other Fees . . . .
. . . . .
ART
IN PUBLIC PLACES -RES
35.12
DIF
COMMUNITY CENTERS -RES
97.00
DIF
CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
67.73
DIF
FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK FEE
.00
DIF
LIBRARIES - RES
225.00
DIF
PARK MAINT FAC - RES
5.00
DIF
PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
21.40
DIF
STREET MAINT FAC -RES
15.00
DIF
TRANSPORTATION - RES
1098.00
Fee summary
Charged
Paid Credited
Due
Permit Fee Total
1536.99
.00 .00
1536.99
Plan Check Total
797.30
.00 .00
797.30
Other Fee Total
2529.25
.00 .00
2529.25
Grand Total
4863.54
.00 .00
4863.54
Installation Certificate: Residential CF -611
Site Address
60-749 Whire Sage Drive
fat '/i
1. BUILDER INFORMATION
Shea Homes - Trilogy - LaQuinta
60311 Trilogy Pkwy
La Quinta, CA 92253-7642
INSTALLING CONTRACTOR:
2. PROJECT INFORMATION
DISTRIBUTION
TYPE
Flexible Ductwork
in Attic and
Between Floors
DUCT OR PIPING R -
VALUE
Flexible Ductwork
Will have a R -Value
of 4.2 or Better
PERMIT #
SUBDIVISION: Trilogy P, La Quinta
CITY: La Quinta
COUNTY: Riverside
WEST PAC AIR CONDITIONING
I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment
installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In
addition, Ihave verified that the equipment is equivalent to or more efficient than the equipment specified on the
Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for
residential buildings.
3. HEATING INFORMATION
HEATING MANUFACT HEATING UNIT ACTUAL EFF. HEATING EQUIP HEATING
EQUIP. MAKE MODEL # AFUE CAPACITY LOAD
Furnace Lennox 80UHG4/5X-100 80% 100000
80%
4. COOLING INFORMATION
COOLING
MANUFACT
COMPRESSOR
ACTUAL EFF. COOLING EQUIP COOLING
EQUIP.
MAKE
MODEL #
SEER CAPACITY LOAD
A/C
Lennox
13ACC-060
12
The building design heat loss and design heat gain rate have been determined using a method specified in Section
150(h) of the Energy Efficiency Standards, and are two of the criteria used for equipment sizing and selection.
6.THERMOSTATIC EXPANSION VALVE (TXV):
Thermostatic Expansion Valve (or Commision approved equivalent) is installed and access is provided for inspection.
Yes F-1 No II NIA I. —]
6. SUBMITTED BY
:Msc- `r"CIO C r t ro a f4y DATE: 6 —3 0 —6,sl
Signature Installing HVAC Contractor
s..•-r.•y=v-•a-r�nrrrrr✓r-iraa.7.:�.ti<Yrx'rrrrrr.-rrsvyrrr�na.rinws.'-re!a•,-.wi•:r•i: A.,oc5a�.v�v.wrnRr.•..r �•� r.. r.=ni;.r..-.r,.fr<.errrrr:u;rvwvnvr�':r��irM•v'•ax�:'��r.�c• ri
5
S
INSULATION CERTIFICATE
r
This is to certify that insulation has been installed in conformance with the current energy
regulation, California Administrative Code, Title 24, State of California, in the building at
60-7.49 WHITE SAGE DRIVE LOT 106.4, PHASE 6A, LA QUI14TA CA
CEILINGS:
TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-38 3
x
WALLS:
TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-13
R
GENERAL CONTRACTOR: SHEA HOMES LICENSE #
s
BY: TITLE: 3
PARAGO SCHMID BUILDING P ODUCTS A MASCO Company LICENSE # 221517
r
BY: TITLE: ACCOUNT REPRESENTIVE DATE: r
r
INSULATION CERTIFICATE
This is t rtify that insulation has been installed in conformance with the curre y
regulation, C " rnia Administrative Code, Title 24, State of California,] uilding located
CEILINGS:
TYPE: BLOW MAUNFAC ertainteed THICKNESS: R-38
WALLS:
TYPE: BLO MAUNFACTURER: Certainteed ICKNESS: R-13
GENS L CONTRACTOR: SHEA HOMES LICENSE #
TITLE:
PARAGON SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517
BY: TITLE: ACCOUNT REPRESENTIVE DATE: