Loading...
06-1587 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 06-00001587 Property Address: 78910 ZENITH WY APN: 609-560-024-24 -23773 - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 7896 Applicant: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Licensee Class: H ( License No.: 412506 Date: V �r Contractor: OWNER -BUILDER DECLARATION I hereby affi-m under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec, 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/12/06 Owner: ROUNDTREE 78-910 ZENITH WAY LA QUINTA, CA 9 VMYContractor. AVILA CONSTRUCT 82567 AVENUE 48, INDIO, CA 92201 Of (760)793-2728 Lic. No.: 412506 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 1;5^04 3,,/700 of the Labor Code, I sh forthwith comply with those provisions. Date: ; 5 '0o Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1- Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county in enter upon the abovermentioned property for eoti on purposes. Data: J'�s —aJl. Signature (Applicant or Agentl: =+.�er Application Number . . . . . 06-00001587 Permit . . BUILDING PERMIT Additional desc . Permit Fee 99.00 Plan Check Fee 64.35 Issue Date . . . Valuation . . . 7896 Expiration Date . 11/08/06 Qty Unit Charge Per Extension BASE FEE 45.00 6.00 9.0000 THOU BLDG 2,001-25,000 54.00 Permit ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . 22.35 Plan Check Fee 5.59 Issue Date Valuation . . . . 0 Expiration Date 11/08/06 Qty Unit Charge Per Extension BASE FEE 15.00 210.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 7.35 ---------------------------------------------------------------------------- Permit MECHANICAL Additional desc . . Permit Fee . . . . 24.00 Plan Check Fee 6.00 Issue Date Valuation 0 Expiration Date 11/08/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 ----------------------------------------------------------------------------- Special Notes and Comments CONVERT 3 DR. GARAGE TO LIVING SPACE.May 12, 2006 8:50:11 AM jjohnson ---------------------------------------------------------------- Other Fees ENERGY REVIEW FEE 6.44 STRONG MOTION (SMI) - RES .78 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 145.35 .00 .00 145.35 Plan Check Total 75.94 .00 .00 75.94 Other Fee Total 7.22 .00 .00 7.22 Grand Total 228.51 .00 .00 228.51 LQPERMIT # City of La Quinta Building & Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: /00 Owner's Name: �+ t 2. A. P. Number: Address: 7 Legal Description: g p � City, ST, Zip: Contractor:��. Telephone: Address: 2d(} Project Description: City, ST, Zip: i R2I Telephone: q3 �.27� State Lie. # City Lie. #: Arch., Engr., Designer: Address: '�i City, ST, Zip: Telephone: Construction Type: •_-_• _.; yp Occupancy: State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.: # Stories- t # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"d Review, ready f correctinu�1171 Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up $ S.M.I. ILO.A. Approval Plans resubmitted W06 Grading IN HOUSE:- '"' Review, ready for correctivuslissuc.. _ . Developer Impact Fee Planning Approval i Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees ! Total Permit Fees r � S CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road BERMUDA DUNES r Date 5/12/06 La Quinta, CA 92253 RANCHOIAN MIRAGE ,� INDIANWELLS M DESERT No. 28466 (760) 771-8515 pAL,QUINT �-� �}+ Va puiNT� � Q ] Owner Roundtree APN # 609-560-024 Address 78-910 Zenith Way Jurisdiction La Quinta City La Quinta Zip Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street Unit 1 78910 Zenith Way Unit 2 Unit 3 Unit 4 Unit 5 Comments S.F. 210 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Lot # No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garagestcarports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 210 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Fred Avila Check No. Name on the check Telephone Funding Exempt By Dr. Doris Wilson Superintendent Fee collected /exempted by Sharon MCGilvrey Payment Recd lo.00 fiver/Under Signaturej4-�'Yq AC, NOTICE: Pursuant to Government Code Section 66020(d)(1), thi w I serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting I TITLE 24 REPORT I 11 Title 24 Report for: Orville and Ruth Roundtree 78910 Zenith Way La Quinta, CA 92253 Project Designer: Jorge L. Garcia 75-153 Merle Drive - Suite B Palm Desert, CA 92211 760.272.9222 Report Prepared By: SLO Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 Job Number: lg05O4O6 Date: 5/4/2006 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTIOM nA7 5 Z E The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.1 by EnergySoft Job Number: Ig050406 User Number: 5732 I TABLE OF CONTENTS Cover Page Table of Contents Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R -0rvilrD_ancLRuth R- aunaitree 5/4/2,006 Project Title Date 7891 n Zenith Way La G}«tS Project Address Building Permit # Santiago Lopez-Ocampo (760) 485-8927 Documen tion Author Telephone Plan Check/Date EnergyPro Com liai rrice Method _ 15 Climate Zone Field Checldoate TDV EnergyUse Standard Proposed Compliance (kBtu/sf-yr Design Design Margin Space Heating 0.35 0.32 0.03 Space Cooling 123.75 120.78 2.98 Fans 17.41 16.95 0.46 Domestic Hot Water 0.00 0.00 0,00 Pumps 0.00 0.00 0.00 Totals 141.51 138.04 3.47 Percent better than Standard: 2.5% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Building Type: Single Family Q Addition Total Conditioned Floor Area: 210 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (S) 180 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 210 ft2 Fenestration: Area: 25 ft 2 Avg. U: 0.65 Ratio: 11.9% Avg. SHGC: 0.40 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACES Insulation Act. Type_ Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnnd 210 o ng.5 R -3R R-0 0 0 1R Wall Wood 62 0.102 R-13 R-0.0 1R0 Wall Wood 163 0.102 R-13 R-0.0 27n 90 Average Ceiling Height: 8.0 ft Number of Dwelling Units: 0.65 Number of Stories: 1 # of Thermostat Units Zone Type Type Vent Hgt. Area 2 n/a Gains Condition Y / N Status JA IV Reference Location / Comments IPNew 01-A1R Rnnm Addifinn New 09-A3 Room Addition _ NBA- 09-A3 Rnom Additin4_ Run Initiation Time: 05/04106 09:35:29 Run Code: 1146760529 EnergyPro 4.1 by EnergySoft User Number: 5732 Job Number: lg05O4O6 Page:3 of 8 Certificate Of Compliance : Residential Part 2 & 3)„ CFA R Orville and Ruth Roundtree 5/4/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments .L Window Front (S) 25.0 0 65l) NFRC OAO NF$G 180 -AQ New t I-V;;IiBanm_Additinn 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC H9t• Wd. Len. Hgt. LExt. REA Dist. Len. Hgt, Dist. Len. Hgt_ 1 Bug Screen 0.76 5.0 5.0 2.3 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Type _ Length R -Val. Location Slab Perimeter 31 None No Insulation JA IV Reference i Condition Location/ Status Comments New Room Addition I EnergyPro 4.1 by EnergySoft User Number: 5732 _ Job Number: lg05O4O6 Page:4 of 8 1 Certificate Of Compliance : Residential {Part 3 of 3) CF -1 R Orville and Ruth Roundtree _ 5/4/2006 Project Title Date HVAC SYSTEMS Location HVAC System ( Existing) HVAC DISTRIBUTION Heating Minimum Cooling Minimum Condition Thermostat Type Eff Type Eff Status Type Central Furnace 78% AFUE Split Air Conditioner _ 9.7 SEER Existing Setback Duct Location Heating Coqlingi Location HVAC System ( Existing) Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Ratedl Tank Water Heater # in Input Cap. System Name Type Distribution Syst. (Btu/hr) (gal) Multi -Family Central Water Heating Details Hot Water Pump Control # HP Duct Condition R -Value Status 4.2 Existing No Ducts Tested? Energy Standbys Tank Insul. Condition Factor Loss R -Value Status or RE 1 M Ext. Hot Water Piping Length (ft Add 1/2" In Plenum Outside Buried Insulation 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Inpui:, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: SLO Title/Firm: Jorge L. Garcia Address: 75-153 Merle Drive - Suite B Palm Desert, CA 92211 Telephone: 760.272. 22 Lie. #: • 0(6 (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Title/Firm: Santiago Lopez-Ocampo Address: P.O. Box 1018 La Quinta CA 92247 Telephone: (760) 485-8927 (signature) (date) (signature/stamp) I_ EnergyPro 4.1 by EnergySoft User Number: 5732 Job Number: Ig050406 Page:5 of 8 Ma' ndatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (") below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. NIA DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ LJ ❑ § 150(b): Loose fill insulation manufacturer's labeled R-V?luL-; ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with§ 151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and El El El CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ Q ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑x ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ Q ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ Q ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with ❑ ❑ ❑ insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1506. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source ❑ ❑ ❑ and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.1 by EnergySoft User Number: 5732 Job Number: Ig050406 Page:6 of 8 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans l 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ I ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating I� dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ b. Cover for outdoor pools or outdoor spas. ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ` 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are I electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ] luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are nol high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in klchens, bathrooms,ggarages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are oonlrelled by a dimmer switch OR are controlled by an occupant sensor that complies with Section 14(d) that does not turn on automafically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor iighbrig and permanently mounted to a realdentlal building or to other buildings on the same lot shall be high efficacy luminaires (not including Ilghting around swimming poolslwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that.00mplies with Section 130, 131, and 146. J § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by occupant sensors) certified to comply with Section 119(d). IEnergyPro 4.1 by EnergySoft User Number: 5732 Job Number: Ig050406 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ IWEEWNI INS a +❑ ❑ ❑ J ❑ ❑ Page:7 of 8 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY (PROJECT NAME DATE Orville and Ruth Roundtree 5/4/2006 --1 SYSTEM NAME FLOOR AREA HVAC System Existing) 210 (ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Hepting System Output per System 0 Total Output (Btuh) 0 Output (Btuh/sgft) 0.0 Cooling System Output per System 1 Total Output (Btuh) 1 Total Output (Tons) 0.0 Total Output (Btuh/sgft) 0.0 Total Output (sgft/Ton) 21520,000.0 Air System CFM per System Airflow (cfm) 0 0 Airflow (cfm/sqft) 0.00 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions EATING SYSTEM - 26.0 of Outside Air _0 cfm 70.0 of 111.0 / 77.6 of Outside Air 0 cfm 78.0/62.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD I I Default FAU/AC 1992 - 2005 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 6,532 616 Total Adjusted System Output 1 a (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK L Aug 2 pm 70.0 OF ■ 110.OoF Heating Coil 4 831 0 Jan 12 am Supply Air Ducts 110.0 of ROOMS 70.0 of Return Air Ducts 4 at Time of Cooli 78.0 / 62.3 of . 55.0 / 53.7 of Cooling Coil o,.a..... A:- n..,.a.. Supply Air Ducts 55.0/53.7OF 41.2% R.H. ROOMS 78.0 / 62.2 of EnergyPro 4.1 by Energy5oft User Number: 5732 Job Number: Eg050408 Page 8 of 8