Loading...
BSPN2016-004778-495 CALLE TAM PICO D �K�IU�iI/ VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENTINSPECTIONS (760)777-7153 BUILDING PERMIT Date:. 6/8/2016 Application Number: BSPN2016-0047 Owner: Property Address: 78120 CALEO BAY LLQ PARTNERS APN: 643200008 801 S RAMPART BLV, #200 Application Description: CHATEAU AT LA QUINTA / ACCESSIBLE POOL LIFT INSTALLATION LAS VEGAS, NV 92253 Property Zoning: Application Valuation: Applicant: Contractor: PRO POOL SOLUTIONS 44185 SONESTA WY t4l* LA QUINTA, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, i'mprove;demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the Z basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: . (_) I, as owner of the property, or my employees with wages as their sole compensation, will db the work, and the structure is not interided or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' . State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). I ) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Add Llc. No.: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: -I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of thew rk for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:_ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become su jaGt.,to the workers' compensation laws of California, and agree that, if I shout ecome subject to the workers' compensation provisions of Section 3 Labor Code, I shall forthwith comply� with those provisions. .�---- pate: 'b/t0 a$ L(0 Applicant: \ b WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state lawsrel 'ngY6bIIilding construction, and hereby authorize representatives of this city to en r upon the above-mentioned property for inspection purposes. OO Date: ko®JD � Signature (Applicant or Agent): � DESCRIPTION FINANCIAL INFORMATION ACCOUNT QTY .AMOUNT PAID PAID DATE SPECIAL INSPECTION 101-0000-42404. 0 $72.52 $72.52 6/8/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY PRO POOL SOLUTIONS DEBIT R16093 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID, PAID DATE SPECIAL INSPECTION PC 101-0000-42600 0 $181.29 $181.29 6/8/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY PRO POOL SOLUTIONS DEBIT R16093 AOR Total Paid for COMPLIANCE SURVEY/SPECIAL INSPECTION: $253.81 $253.81 TOTALS: $253.81 $253.81 N: Description: CHATEAU AT LA QUINTA / ACCESSIBLE POOL LIFT INSTALLATION Type: SPECIAL INSPECTION Subtype: Status: APPROVED Applied: 6/8/2016 AOR Approved: 6/8/2016 AOR Parcel No: 643200008 Site Address: 78120 CALEO BAY LA QUINTA,CA 92253 Subdivision: PM 27892 Block: Lot: 8' Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 ..,,,NAME TYPE NAME ADDRESSl Details: ACCESSIBLE POOL LIFT INSTALLATION ONLY, AQUA CREEK PRODUCT TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS. THIS PERMIT DOES NOT INCLUDE ELECTRICAL INSTALLATIONS, SELF CONTAINED EQUIPMENT. 2013 CALIFORNIA BUILDING CODES. ADDITIONAL FINANCIAL CHRONOLOGY INFORMATION CONDITIONS AMOUNT PAID CONTACTS METHOD PAID BY CLTD . BY ..,,,NAME TYPE NAME ADDRESSl ......... CITY ..... STATE ZIP PHONE FAX EMAIL . APPLICANT PRO POOL SOLUTIONS 44185 SONESTA WY LA QUINTA CA .92253 (702)967-5000 OWNER LLQ PARTNERS 801 S RAMPART BLV, #200 LAS VEGAS NV 92253 (702)967-5000 Printed: Wednesday, June 08, 2016 4:02:26 PM 1 of 2 SYSTEMS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD . BY SPECIAL INSPECTION 101-0000-42404 0 $72.52 $72.52 6/8/16 R16093 DEBIT PRO POOL SOLUTIONS AOR SPECIAL INSPECTION PC 101-0000-42600 0 $181.29 $181.29 6/8/16 R16093 DEBIT PRO POOL SOLUTIONS AOR. Total Paid for COMPLIANCE SURVEY/SPECIAL INSPECTION: $253.81 $253.81 Printed: Wednesday, June 08, 2016 4:02:26 PM 1 of 2 SYSTEMS Printed: Wednesday, June 08, 2016 4:02:26 PM 2 of 2 SYST[:'ivt S DESCRIPTION PermitTRAK ACCOUNT QTY ------------ PAID _ $253.81 BSPN201670047. Address: 78120 CALEO,BAY Apn: 643200008 $253.81 COMPLIANCE SURVEY/SPECIAL INSPECTION $253.81 SPECIAL INSPECTION 101-0000-42404 0 $72.52 SPECIAL INSPECTION PC 101-0000-42600 0 $181.29 • + + R16093 i g Zp16 jU I SUN 0 COti4MUNT�e Date Paid: Wednesday, June 08, 2016 Paid By: PRO POOL SOLUTIONS Cashier: AOR Pay Method: DEBIT Printed: Wednesday, June 08, 2016 3:58 PM 1 of 1 CYCTFAAC Din # C(ty of La Quin to Building 81• Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Applicationh _ r 'n Shee WOW Permit # Ob- ooh Project Address: 8 12.0 vCco Owner's Name: LA Vf t A. P. Number: Address: 2 6 'Zp r�� d Legal Description: City, ST, Zip: UA R,0 t3 �A N 9-, nn Q ` Contractor:T �O 9 S eIP e hone Z6C � 3 ... Address: C> ^ O 6 8� Project Description: /� D4 Project M `-t A 1 ICS.... City, ST, Zip: LA QJ 1 N R a g,4Cv c`�O C • --+ �-.� Telephone: o. e: 1 O � -O`1t� State Lic. # : City Lic. #.. I l 1 S S Arch., Engr., Designer: Address: City., ST, Zip: Telephone: h one: ^_ Construction T e: Occupancy: type: cu an cY: P State te Lic.#: Project type (circle rcle n e). New Add'n Alter Re air Demo Name of Contact Person: dr--E�R� Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: !;l2 b L . l 8 S8 TEstimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction ' Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for corrections/issue Electrical, Subeontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"! Review, ready for correctionstissue Developer Impact Fee Planning Approvil Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees LA .�QU N1M �O .a as 48 ai'J-rg , CA (1ho) 404-011&°1- pttvN� (ib�) 544 --1 �76po> 6310 - la's'$ - Fox fnkK . Sia laFt a 3'/Z CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED - FOR CONSTRUCTION DA IO 20t(P sy Aqua Creek Products LLC. Packing Slip 9889 Garrymore Lane Date S.0, No. A4091 Creek Produce Missoula, MT 59808 6Yse iafa15o4A3oa fw Pool atd spa AMOS 5/27/2016 35134 r hip To Chateau at Lake La Quinta (760) 564-7332 120 Caleo Bay Quinta, CA 92253 YEst. Ship Date Ship Via FOS P.O. NO. Pmt.Terms Series flap �: 909402, 03, 04 Net 30 Tom K 6/1/2016 Reddaway ORIGIN PP&ADD pt®at ' �' ®riirea9 Shipper! Ranger -AT, No Anchor (ITS PO# 909403) 2 F-411 RPL -ATI Anchor Kit;'4iPoint,' Ranger/ProPool Lifts {ITS PO#, F-04CA1F ; Cover, Pro Pool Series, Lockable, Blue Canvas (ITS PO# 909402) 3fl4: , ,1 I.� - TF�IJCKFREi F1T Sliippinb�'-T uc reigh Pa femg & Iandting, Commercial Delivery with Liftgate and Pre Delivery; Notification Phone # Fax # Web Site 406-549-0769 406-549-2602 www.aquacreek.com :i .......... .................................I Aqua Creek Products The Leaders of Recreation, Fitness and Ability! N Avmsenmm, Afichn fistmc Oafls PART #: F-04CAJP i Pool Lift - Weight Capacity (450 LBS) / Max Setback (19") Pro Pool Lift Ext Base 23"- Weight Capacity (450 LBS) / Max Setback (23") Pro Pool Lift Ext Base 26"- Weight Capacity (450 LBS) / Max Setback (26") Pro Pool Lift Deep Draft - Weight Capacity (400 LBS) / Max Setback (17") Ranger Lift - Weight Capacity (350 LBS) / Max Setback (19") Pathfinder Lift - Weight Capacity (300 LBS) / Max Setback (16") MANDATORY — LEAVE THIS MANUAL WITH LIFT OWNER ARead & Follow All Instructions Lift safety can only be ensured if the lift is installed 9 and operated according to these instructions NEVER permit children to play on or around the lift. Do not allow children to use the lift without adult supervision. NEVER apply direct water pressure to the electronics NEVER use the lift with a dry pool ✓ X 9889 Garrymore Ln Missoula, MT 59808 888-687-3552 1 +1-406-549-0769 aquacreek.com For safety reasons, NEVER swim alone SAVE a copy of these instructions 1 Copyright © 2016 Aqua Creek Products All Rights Reserved Revised 2/1/16 Front Anchor Setback Distance Chart Lift Model Min Setback Max Setback I Pathfinder 14.5" 16" Ranger 14.5" 19" Pro Pool 14.5" 19" Pro Pool 23" Ext Base 19" 23" Pro Pool 26" Ext Base 23" 26" Pro Pool Deep Draft 14.5" 17" Note: All setback distances are based on a straight pool wall. Setback distances will change for curved pool walls. Contact Aqua Creek for curved wall setback distances. F-04(AJP: AT Anchor Assembly Parts List ------------- ------- :----------------------------, F-044ANI 1 2 7 5 M 4 6 8 9 4 1 Ill F-433JIG-AT (�) � I ITEM # QTY PART # DESCRIPTION 1 4 BH 1/2 X 1-1/2 BOLT, 316 SS, 1/2-13 X 1 1/2 HCS 2 4 WF 1/2 WASHER, FLAT, 1/2,316 SS 3 1 ANTI SIEZE, PACKET, .75 ANTI SIEZE, PACKET, 5GRAMS 4 3 P-7200ANB ANCHOR INSERT, NON -BONDABLE 5 1 P-7200ANB-BB ANCHOR INSERT, BONDABLE 6 8 NH 1 ZINC NUT, ZINC, HEX, V-8 7 4 PIP -1/2 -TAB TAB, PIP -1/2, BLACK CAP 8 1 WF 1/4 WASHER, FLAT, 1/4,316 SS ; 9 1 SPH 1/4 X 3/4 BRASS SCREW, BRASS, 1/4-20 X 3/4" PANHEAD ITEM # QTY PART # DESCRIPTION 1 1 GBL-4DB LUG, IN GROUND BONDING LUG 2 1 P-004CPPJP-A JIG PLATE FOR PRO SERIES LIFTS 3 1 NN 10 NUT, 316 SS, NYLOCK, #10-24 :I 1 BSH 10 X 3/4 BOLT, 316 SS, 10-24 X 3/4 SHCS 1 P4 5 1 LABEL #97 REFER TO MANUAL FOR PROPER SETBACK Copyright © 2016 Aqua Creek Products All Rights Reserved 2 Revised 2/1/16ij I' ' The AT ANCHOR ASSEMBLY will come fully disassembled. Review the diagram below to familiarize yourself with the components before beginning the installation. The anchor assembly is used in different ways, depending on your type of installation. For instance the ANCHOR JIG -PLATE can be used as a template to mark the holes for retro -fitting, to hold the ANCHOR INSERTS at the proper spacing as the epoxy cures (see RETROFIT INSTALLATION), or as a permanent part of the installed/ embedded assembly. LD i 1/4 FLAT WASHER - 1/4 X 3/4 PAN -HE BOLT Ov. 0 1/2" X 1-1/2" HEX BOLT (4) 01/2" FLAT WASHER (4) 0 1" X 4" ANCHOR - INSERT (4) 0 1" HEX - NUT (8) i #10 X 3/4" ,i -----HEX BOLT GBL-4DB BONDING- LUG Copyright© 2016 Aqua Creek Products All Rights Reserved I0 NYLOCK ANCHOR JIG -PLATE 3 Revised 2/1/16 0nstffldkaoo ADA Wddkes ADA REQUIREMENTS: The Pathfinder, Pro Pool, and Ranger lifts are completely ADA Compliant when installed correctly. The installation must meet the following requirements: • Clear Deck Space Dimensions (see FIGURE 1) o Reference Anchor Setback Distance Chart (see PAGE 2) o Deck slope no greater than 1:48 0. The seat must go at least 18" into the water. The lift should be installed at a location with a water depth of 42"-48" (deck to pool floor) *NOTE: 29.5" TO START OF ADA CLEAR -DECK SPACE IS FOR THE MINIMUM 14.5' SETBACK. WHEN SETBACK 19" THE CD -SPACE STARTS 34" FROM THE POOL WALL. (SETBACK + 15") 50" 48" — ---------------------------------------------------------------; ; ; i ADA REQUIRED 36" CLEAR DECK SPACE (36" X 48") 12"--------------------------------------------------------------- t i O CHAIR y, ' �E *29 1/2" - 11" 1611 **SEE MIN - CHART POOL WALL FIGURE I **NOTE: FOR SETBACK DISTANCES REFERENCE SETBACK CHART (PAGE 2) n Copyright © 2016 Aqua Creek Products All Rights Reserved Revised 2/1/16 AnchoT �nstdationo, Cm-dflfl Refto-fit NOTE: FOR DECKS 6"THICK OR MORE, 250OPSI MINIMUM STRENGTH CONCRETE REQUIRED You will need: i, • Core drill and 1 1/2" core drill bit • Tape measure • Marking pen • Hammer • Cold chisel • Torpedo level • High strength 2 -part construction epoxy* • Masking tape • Black electrical tape (optional) *Aqua Creek recommends either Hilti°" Brand HIT RE - 500 -SD or Simpson'' brand SET -XP or equivalent (not i included) Q, tea, W O a Reference Setback Distance Chart IDAGc .2l Anchor jig plate with hardware 1. Mark the 4 hole locations on your deck using the larger holes of the anchor jig plate as a template. Make_sure_the.center_of_the_holes_on the_anchor_ jig_plate_are_aligned.according to your lifts_setback_distance._sEE-FIGURE 2.&.PAGE 2 2. Drill out the 4 hole locations to about 4 1/2 inches deep using the 1112 inch drill bit. Make sure the holes are completely dry and clear of debris. FIGURE 2 NOTE: Create a depth marker on the drill bit with black electri- cal tape to make sure you drill to the right depth i►NOTE. Your local bonding regulations may require you drill one hole larger than the others in order to bond at least one of the anchor inserts. You may need to saw cut a portion of your deck. See "Saw Cutting Retro -Fit Instructions" on page 7. 0. Remove the nuts and the black protective coverings from the threaded anchor inserts. continued on page 6 5 1. Copyright © 2016 Aqua Creek Products All Rights Reserved Revised 2/1/16 i Anchor Installation: Core -drill Retro -fit (CONTINUED) 4. Thread the mounting hardware through the smaller anchor plate holes and into the :. anchor inserts. Make sure to use Anti -seize on the threads! Make sure the tops of the T 1' inserts are flush with the bottom of the plate. i NOTE. We recommend using masking tape around the holes on the bottom of the anchor jig plate to help prevent ' the anchor plate from being accidentally epoxied to the pool deck.!r l'i. 5. Bond at least one of the anchor inserts according to your local code requirements. For more, } information see NEC Article 6. Test fit the anchor inserts to ±� j make sure they line up properly. Place the anchor assembly into the pre -drilled holes and use a torpedo level to check if your anchoring system will be level. 7. Remove the anchor assembly , and fill each hole halfway full with�E 2 -part construction epoxy. 8. Place the anchor assembly back into the holes. Wiggle the assembly as you reinsert it to make sure the epoxy fully coats the threads. 9. Make !sure your anchor assembly is level. 10. Once the epoxy has set up remove the hardware and the anchor jig plate. Your lift is �! ' now ready to be mounted to the anchoring system. The anchor jig plate may be recycled and/or used to install other anchors. Copyright © 2016 Aqua Creek Products All Rights Reserved Revised 2/1/16 M *REFERENCE SETBACK DISTANCE CHART (PAGE 2) 2.5" 8 -AWG SOLID -COPPER WIRE MIN (ATTACH TO BONDING -GRID) I r BONDING i° i.. r� 42" OR 48" .j 250OPSI MIN FLUSH W -DECK 4" #4 REBAR EACH WAY (10 PCS) DRILL & EPDXY INTO EXISTING FIGURE A SLAB (4" MIN EMBED) Anch�P W��0�atu000e Sawed Rei�Qc-�ut You Will Need: • Concrete saw with diamond blade • Torpedo level • Tape measure • String Line • 4' long straight edge or chalk line -LUG • Sledge hammer finishing tools • Cold chisel • #4 rebar A �4 REBAR POOL WALL Anch�P W��0�atu000e Sawed Rei�Qc-�ut You Will Need: • Concrete saw with diamond blade • Torpedo level • Tape measure • String Line • 4' long straight edge or chalk line • Concrete & concrete • Sledge hammer finishing tools • Cold chisel • #4 rebar 1. Remove 1 nut from each anchor insert. Place the anchor inserts through the larger hole of the anchor jig plate. Thread the removed nuts back onto the anchor inserts. The anchor plate should be sandwiched between the two nuts on each anchor insert. SEEFIGUREC 2. Mark out a section of the pool deck you are removing. Plan on removing at least 4'x 4'x 6"for Pro Pool lifts and 3'-6" x 3'-6" x 6" for Ranger and Pathfinder lifts. It must be reinforced with 5 sticks of #4 rebar EVI 2" clear (min) from the top and bottom of the footing. .I 3..Cut along your marks with a diamond blade concrete saw. 4. Using the sledge hammer, break up the concrete within the area you cut and remove the pieces. 6. Install rebar in the open area of the deck. Tie the rebar into the existing deck if possible. SEE FIGURE B .7., Set the anchor system in place. Make sure the center of the large anchor jig plate holes aren't set back further than the max distance provided on page 2. FIGURE C FIGURE 8 8. Using the string line or a straight edge, make sure the top of each anchor body is level with the FINISHED deck surface. Each anchor body can be adjusted individually by turning the nuts with a large wrench. 9. Bond the anchoring system according to your local code requirements by using the bonding lug on the anchor plate. SEE FIGURE A (See NEC Article 680.26) 10. Pour your concrete and finish the pool deck surface. SEE FIGURE C 11 11. Once the concrete has cured, your lift is ready to be mounted to the anchoring system. SEE FIGURE C 7 Copyright © 2016 Aqua Creek Products All Rights Reserved Revised 2/1/16 "REFERENCE SETBACK DISTANCE CHART (PAGE 2) 2.5" 8 -AWG SOLID -COPPER WIRE MIN (ATTACH TO BONDING -GRID) ` Cm -m7 MELON0 0, 00 N e 42" OR 48" .j 250OPS1 MIN FLUSH W -DECK 4" .f. :.: .i ..ti.....U06a 1t4 REBAR EACH WAY (10 PCS) DRILL & EPDXY INTO EXISTING FIGURE A SLAB (4" MIN EMBED) Copyright 0 fl ■ Anchou V Ufist@H@Nafl.o MAJ constudon NOTE: For installations where a new deck is being poured, or where a dedicated pad is being poured just for the pool lift, the concrete must satisfy the ADA requirements outlined on page 4 of this manual. Your pool _deck must be at least_ 4' x 4' x 6" for,ool_lifts and 3'-6"_ x 3'-6" x6" for_RanaerJ and Pathfinder lifts._It must be reinforced with 5 sticks of #4 rebar E -1N, 2" clear_(min) from the top] ,and bottom of the footing 1. Remove 1 nut from each anchor insert. Place the anchor inserts through the larger hole of the anchor jig plate. Thread the removed nuts back onto the anchor inserts. The anchor plate should be sandwiched be- tween the two nuts on each anchor insert. SEE FIGURE C 2. Install rebar in the open area of the deck. SEEFIGUREB FIGURE 8 3. Set the anchor system in place. Make sure the center of the large anchor jig plate holes aren't set back further than the max distance provided on page 2. 4. Make sure the top of each anchor body is flush with the FINISHED deck surface. Each anchor body can be adjusted individually by turning the nuts with a large wrench. FIGURE C 5. Bond the anchoring system by using the bond- ing lug on the anchor plate. Bond the system according to your local code requirements. SEE FIGURE (See NEC Article 680.26) 6. Pour your concrete and finish the pool deck surface. SEE FIGURE C 7. Once the concrete has cured your lift is ready to be mounted to the anchoring system. SEE FIGURE C R] 2016 Aqua Creek Products All Rights Reserved Revised 2/1/16 lift Installation and Removal Once the Anchor has been installed and allowed to set for at least 48 hours, the pool lift may be installed and operated. The 1/2"x 1-1 /2" Hex Bolts will be used to fix the lift safely and securely to the pool deck. STEP 1: Using a hand -truck or the Aqua Creek Products Transport Cart (F-428HT shown - sold separately) carefully move the lift to the anchor location. Orient the anchor -bolt holes in the base -plate of the lift over the four (4) anchors. Lower and adjust the lift until all four holes line-up. r '. STEP 2: Place one of the 1 /2" FLAT WASHERS over an anchor -bolt hole as shown. Install one of the 1/2"x 1-1 /2" Hex Bolts into the hole, through the flat washer. STEP 3: Hand -tighten the anchor bolt as shown until tight. USE A 3/4" SOCKET OR WRENCH TO TIGHTEN. Repeat steps.2 and 3 for all four bolts. �f LIFT REMOVAL: To remove and transport the lift, reverse steps 1-3. Store the anchor -bolts and washers with the lift for easy retrieval. D Copyright © 2016 Aqua Creek Products All Rights Reserved Revised 2/1/16