Loading...
9705-067 (SFD)LICENSED CONTRACTOR DECLARATION / I hereby affirm under penalty of perjury that 1 am licensed under provisions of i— Chapter 9 (commencing with Section 7000) of Division 3 of the Business and C\1 W Professionals Code, and my License is in full force and effect. O Z License # Lic. Class Exp..Date W c�:li�)Hi R O•,I I/3I/98 Zr,- VDate Signature of Contrac o + w OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's ~ License Law for the following reason: Z_ ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). co () I am exempt under Section , B&P.C. for this reason L N Date Signature of Owner O� Q WORKER'S COMPENSATION DECLARATION CD Cc I hereby affirm under penalty of perjury one of the following declarations: Lo H O () 1 have and will maintain a certificate of consent to self -insure for workers' X w �= compensation, as provided for by Section 3700 of the Labor Code, for the O � Q performance of the work for which this permit is issued. m Q C) ( ) I have and will maintain workers' compensation insurance, as required by OU Q Section 3700 of the Labor Code, for the performance of the work for which this d 0 Z permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. cliO DI;N IN& J (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if) should become ubject to the workers' compensation 'Provisions of Section 3700 of the Labor Dode, I shall forthwith comply with`those provisions.#/ ate:/ /Applicant - Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is • correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property f • r inspectio ,purposes. VS (Owner/Age..., r(� /r D BUILDING PERMIT PERMIT# r:(1NTRr)1,u 74111.5- 7 5330 DATE W 10/97 VALUATION 5124,.322.70 LOT I'll TRACT DE'S lRTC'I,11 JOB SITE*� ADDRESS 78-684) A.VkNI0A LA JA.R11A APN + 769435.07 OWNER CONTRACTOR / DESIGNER / ENGINEER . iJIEL lrORONI:I, CORONEL CONKI'II.IJ ,MON P.OBOX 383 P.O. BOX 310 LA QlANVA CA 92253 LA tai lIWA CA 92253 (760)W. -4604. CLAUt 2261 USE OF PERMIT !'F.t��,"1'vN1i1'lti1�.I'i� SAI f1, t�f112C�tIfI�A'i'k),� :�i5.f>R) tiiT i C' IARAC3ilr:Aizl'I. RT 6660) SF 0111111A Aria: COS t�tl� C-UNSTRUC7110N 124, 226.70 RR .i#tt,*k 11I i� iii C�41 Nil I fit lll�AIRY lIA! 101-mll''-418-ow irf,�M1f (':'G'►: t°'W' .i 1A.P011411 . •.♦O 50.00 NI) vdIIAN1-'.AL 14, R iCtl tN� +12I-iwii >�c;t�.rc) I ! !i<;"f'i2If�AI. Ftil? 101-000-420-000 S! Iti.Kt i� frl,{J)ttltit,)C� ITI'T lI}l-CI(1n •i�!� lN? Sidf)'15 ® C" .°:11ltdt NIC11'lt:1t.PUT —141?`40 101-0004141-000 $12.43 02 (lit Avlfmt1,.11.1 ire -t?t34 � Z3 t)f10 20:iwi � `"C 11�iTKA .I Ktlt:'i`lflijt ITE 725.0W-441-342 37.,7f 3.ttti Z tsl2tr';IIIsl'!,!4Pa I�z-(i(H)•+jril�3�l;� ART IN PUBLIC 1'1 A0:3 - RESIU 70!-UUCP-255dMt1 $0,8 f l.Jk3-K)TA(.Ctal°f1MKIJM, ION.Ai+ DP1.AN CfU-.* CK ""i, . $4,,501.28 LESS PRE-PAIDITI-Ug" 42511.00 1111'AI,1'ij:RMIT i+ RY-4; 0111Y, NOW $4,251.28 RECEIPT DATE BY DATE FINALED INSPECTOR 61 ' pie-. INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade 6 2f Return Air Steel i Combustion Air Roof Deck 7 7 Exhaust Fans O.K to Wrap F.A.U. Framing , Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final POOLS - SPAS BLOCKWALL APPROVALS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg.' Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines 24 Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation " Gas Piping Gas Test _ Appliances Final COMMEN S: �� - Final Utility Notice (Gas) ELECTRICAL APPROVALS .. Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) r 4,4 Q - P.O. BOX 1504 APPLICATION ONLY Building 'D7&105 78-105 CALLE ESTADO "Address 1�+1" 11�1� LA.QUINTA, CALIFORNIA 92253 OwneOwner q--� rrYt/ s �- �—• C . G',��/1<' ( , g�i ' 7 BUILDING: TYPE CONST.—OCC. GRP. Mailin Address p 0,r &ar fe? f A.P. Number Cjt // // Zip Tel 1 F%2S �6�/"'L/� a�7' Legal Description f-�T 13/� �C ���� /r c� Contyajrtor Project Description (C Ot-Y� C i I Address City �Zip �ZZTel. �� P 7 State Lic. ^ / _' City & Classif. l � (_�, it # eS I Sq. iz Ft. /J t7 No.' No. s Size i Stories Units Arch., Engr., Designer New Add ❑ Alter ❑ Repair ❑ Demolition, ❑ Address Tel. City Zip State Lic. # LICENSED R' RACTOR'S DECLARATION I hereby affir at I am license under provisions of Chapter 9 (commencing with Section 7000) of Divi o 3 of the sine and Professio e -a d my license isjRtful) jorcl;7 effect �7 7 / SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following Estimated Valuation . reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to AS issuance also requires the applicant for such permit to file a signed statement that he is liceraed pursuant to PERMIT AMOUNT the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit Plan Chk. Dep. subjects the applicant to a civil penalty of not more than five hundred dollars (5500). (7 I, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal. do the work, and .the structure is not intended or offered for sale. (Sec. 7044, Buisness and Const. Code: The Contractor's License Law does not apply to an owner N property who builds or improves thereon and who does such work himself or through his .)wn employees, Mech. provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will Pave the burden Electrical of proving that he did not build or improve for the purpose of sale.) II I, as owner of the property, am exclusively contracting with licensed cortGractors to con- Plumbing strucI the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for S.M.I. such projects with a contractor(s) licensed pursuant to the Contractor's License Law Grading 0 I am exempt under Sec. B. & P.C. for this reason Driveway Enc. Date Owner Infrastructure WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) 1 Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished, 1 TOTAL CERTIFICATE OF EXEMPTION FROM REMARKS WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker? Compensation Laws of California. Date Owner - NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become ZONE: BY: subject to the Workers' Compensation provisions of the Labor Code, yo+ must forthwith Minimum Setback Distances: comply with such provisions or this permit shall be deemed revoked. Front Setback from Center Line .Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY i "i Side Street Setback from Center Line I hereby affirm that there is a construction lending agency for the perbrmance of the • work for which this permit is issued. (Sec. 3097, Civil Code.) Side Setback from Property Line ' Lender's Name Lender's Address FINAL DATE I f�T This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. ' I certify that I have read this application and state that the above information is correct. Issued by: Date Permit I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to en,er the above- validated by: MAY 1 3 1997 mentioned property for inspection purposes. Signature of applicant Date Mailing Address Validation: City, State, Zip C1 C CIF D 1. �.. BUILDING DIVISION ` ' CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEED 1ST FL, SO. FT. @ $ 2ND FL, SO. FT, t<g POR. SQ. FT. @ GAR. SO, FT, CAR P. SO. FT. 0 WALL SO. FT. 0 SO. FT. @ ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN URINAL WATER PIPING NOTE: Not to be used as property tax valuation BONDING FLOOR DRAIN MECHANICAL FEES FORMS WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GAS (ROUGH) GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED OTHER APPJEQUIP. LAUNDRYTRAY AIR HANDLING UNIT CFM TEMP. POLE KITCHEN SINK ABSORPTION SYSTEM. B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE,TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. @ c BATH TUB SQ. FT. p c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11A c SEWAGE DISPOSAL SO.FT.GAR @ 3/<c HOUSE SEWER REMARKS: VENTILATION GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST, FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING& AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ _$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATIONISOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL Notice: Document Cannot Be Duplicated Desert Sands Unified School District 82-879 Highway 111 Indio, CA 92201 619-775-3500 CERTIFICATE OF COMPLIANCE Date 6/12/97 APN # 769-135-007 No. 15656 Jurisdiction La Quinta Owner Name Esequiel Coronel Permit # No. 78680 Street La Jarita Log # City La Quinta Zip 92253 Study Area 115 Tract # Lot # Square Footage 1972 Type of Development Single Family Residence No. of Units 1 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.84 X 1,972 or $ 3,628.48 the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued Fees Paid By ccNalley Independent Bank/Coronel Enterprises rTelephone`•: Name on the check By Dr. Doris Wilson �. Superintendent Fee collected /exempted by Pauline Pearson Payment Received $3,628.48 Check No. 141487 Signature 1 Pl n A 10TICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified bove will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to ollect them on the Dislrict('s)(s') behalf, whichever is earlier. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting > JAMES O. WALLACE Agricultural Commissioner Director of Weights & Measures OFFICE OF THE AGRICULTURAL COMMISSIONER CALVIN C. KAMINSKAS P.O. BOX 1089 Assistant Commissioner RIVERSIDE CA 92502-1089 DAN RILEY PHONE (909) 2753000 Sealer, Weights & Measures FAX (909) 275-3012 (909) 2753030 FAX (909) 276-4728 ` 46-209 OASIS STREET, ROOM 14 INDIO, CA 92201 (619) 863-8391 DATE 5Z.zA97 CASE NO. DEVELOPER'S NAME: ADDRESS: TELEPHONE: Dear Developer$: After reviewing your landscaping plants, all plant material listed is not in violation of quarantine laws governing the Coachella Valley. If substitutions do occur and they differ from plant material listed, this office must be notified immediately. Thank you for protecting and preserving the Coachella Valley's pest -free environment. Agricultural Commissioner' ffice cc: Indio and Riverside JUN -12-97 11:49 FROM: VIH-C.V. LOAN CENTER ID: 6197757055 un. 11, 1997 cl l , �i4ARi 0, C. T. CYNTHIA KACX FAX K0. 9093703332 No. 93's5. P. OPME {OMT TITLB CWPACOMPOY ! s 97.6i05KC R-157246-1 911th= RRcowso wa)L TRIS I)W= AND, � L TA ��S TQB,DN. 992091ML M, C011WSL sl -Sic BICSSRNOWn DRYVE LA gaiNI•A. CALTV010IA 92253 PAGE 1 C 0% pla Ar I T of Document R®cetd®d on.4AAZ Nm aaU 2.2 was not been compared with original. COUNTY RECRRpER Alai 760-135.007 GNAW DEM -Nth..e The undersigned grantor M declass(®) : Documentary transfer tax is �wo fdc Cesm uted On full value of p arty 0onveyea. or Comuced Ort hail. value lase pians Sildl andNoftraao®e remaining ac ticau ofnge610. %Mincorporate:d ares: ( ) city/ of -- -- _ FOR & vAJARWA CMIDERATION. sace+ipoa 09 whiCh is hersbY aeknOvledged. A S N CONSTRUCTION, A CAY+Ir=zA PARTB(BRS) rr hSY'eby OpiFI'C (S1 co `iBQt)yxL H. CORDNXL, A SINGLB WW the seal propetty in chs City Ot XJ► QUIlTA, Ownty of Kiverat", Stare of Callfc)gnia, desczibe6 es W? iii OF nssz ' CLue TAA" WIT Mg. 5, AS SI.W N By vAP ON FILE IN HOOK 21 pRogg gl MM 63 OP XApq, RgCORbS dy RIVRRSIM CITY, CAJLIPONIA Dotard April, 21. 1997 Vote of California county of •- itivmi4a i S.S. be�fora ono. Cxe T omich . personally appeared yos:eenally. known to tae (or proved to me on the basis of satiSfactOly evidence) to be -.he person (0 whose name (el is/are Soebaeribed io Che within .inscrument ned acknowledged to ooa that hr/at,®/they executed the same in hisiherichei3r authorized 0PAcity(0e) , and that by thio/her/tlteir aigna'ture(el on the instrument the poreOnW , or the 61%tity upon behalf of which tM Varson(s) acted, executed the instrument. tIl'CiISdS my d-'eroetc s"ir jr !!ptt..�._� w1ge9ature MA'X16 To 871=10:5 Too sm A5 AIM A 6 M 966nucTION A CAS IA PARTNIRSHI• P N do/title Hama/Tt.e le irns"a ' 109 8e1101 (This area for of ficial nots►rial seal) fo 7r 2.`*6•Q.1 »ten A RE -INSPECTION FEE OF $30 iw,,,, WILL BE CHARGED IF THE APPROVED r• ..c '� ; �, • Dwual �1t" Y PLANS AND JOB CARD ARE NOT ON - THE SITE FOR A SCHEDULED IH SPEMOX ,. :. _ ..:. .. ... _ _ _ •TIO OWTIONS1 New 644: a 1 ; .... . uy1,,, . -r ... • ... .. . wt �,i ;pita, iLRhsMtS rn Inch. 11 d � X17 MMMONN0.1000MCW1XMIOR• OFA/C �'T CITY OF LA QUINTA BUILDING & SAFETY DEPT, APPROVED FOR CONSTRU O . SO . ci.p � k r O{rt�ca ov, S 1�e�c-,�: -btu- P, dAPI"VgDWTi OMWN/V •.. DARS T mtego ONAWOte NYM9= t, 4-o, ''C, `9tt9 -771-lobo 1 MANDATORY MEASURES CHECKLIST• RESIDENTIAL (Page I of 2)MF-1R Nutc: Luwrise msidential buildings subject to the Standards roust contain these measures regardless of the compliance approach used Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all panics as minimum component performance specifications for the mandatory measures whether they arc -shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. .r-nrn ro-rmnwm DESIGNE FORCE Building Envelope Measures: JIM&): Minimum R-19 ceiling insuhlion. _ §tso(b): Loose flu insulation manufacturer's Iabeld R -Value. § I Ac): Minimum R-13 wall insulation in wood frmed wails or equivalent 1.1 -Factor in meta( five rolls I A f FY §150(d): Minimum R-13 raised nmr inmlatian in (rand Goan. § 1 Soil): Stab edge iosuluion • water abmrption rue an greater than 0.3%. water vapor transminim rate eco Water ti 2 0 pe..ch §118: Insulation specified a insW led mews insulation quality assailants. Indian type and form. § 116.17: Fenestration Products. Exterior Doan, and Infdtration(Eafiltntien Controls I. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except fhdki-fabricated) have label with certified U -Furor, certified Sol; Hat Gain Caefllcient (SHOO). and infiltration certification. 3. Fataior doom and windows wuNmuipped; all joints and paaeustions au(ked and sealed § I Will: Vapor barriers mandatory in Climate Zone 14 and 16 only. § 1 50(n: Special infduation barrier installed to Comply with § Irl mccu Commission gafiry standards. § I30(e): Installation of Fireplaces. Decmntive Gu Appliances and Ws fags. 1. Masonry and factory -built Grcplaen have: a. Closeable maul or glass door b. Outside air intake with dumper and central c. Ft. damp. and control 2. No continuous burning gas pilot lights allowed Water Heating ind Plumbing System Measures: § 110-0 113: HVAC equipment. water hatm. Nowerbeads and faucets certified by the Commission. V J L § I s0(h): Haling udlor cml(ng loads alcdatd in amotdanee with ASHRAE. SMACNA a RCCA. § I 50(i): Setback thermostat eco all applicable hating &War cmltng systems. §1500): Pipe end tank insulation I. Storage pi water, haters mid with an Energy Faster less 11111110.58 must be atema0y wrapped with insulation having an insWled thermal resistance of R-12 or grata. 2. First s feet of pipes closed to water hatcr tank, non-mcnamluing systems. insulated (Ria or Fula) 3. Back-up oaks for sol; system, unfired storage tanks, or other Indirect hot water tares have R-12 atemal insulation or It. 16 combined iotereal/ataoal msulatioo. 4. All buried or exposed piping insulated in recirculating'"tions of hot water systems. s. Coaling system piping below ss' F inculsted. 6. Piping insulated between hating Nurce and indirect hot water tank. MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page 2 of2) MF -111 Note: Lowrise residential buildings subject to the Standards b must co Iain in ten cam sures regardless Of the od nianccethe a approach of items marked with an asterisk (•) may pe Y 8 P req Compliance. When this checklist is incorporated into the permit documents, the feasums noted shall be considered by aE panics as minimum component performance specifications for the mandatory measums whether they are drown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. Space Conditioning, W>iter Heating and Plumbing System Meaeures: (continued) • §ISO(m): Duuand Fans 1. All duets amt plenums installed sealed and in"td to meet the requirement of mfr 1998 CMC Sec6ms 601. 603, 604. and Sundud 6.3: taco insulated ; a minimum ins Wlcd level of Ri.2 a mlmW entirely in maddened space. Openings shall be scaled with mastle, tyx, aerosol sealant, or other dun -annum system gut moots the applicable roquinenmu of Lq. 181, UL 19 IA. or UL 181 B. If mastic or ape is used to real openings gaster than 114 Inch, the combination of mastic and either mesh or tape shag be used building avidea also Do be used for conveying conditioned ab. Joints and aams of duct systems and their compenonts shall not be sealed with cloth buk rubber adhesive duet tape colas such upe is used in combination with mastic and dm binds. ..� 2. Building esvides, support platforms for It hmdlm, tad plenms defined or constructed with materiels other than scaled thea meal, dun baud or flexible slue) shall not be used for eenveying conditioned ab. Bull&& unties and suppon platforms ray contain duets. Duets installed in cavities and suppon' pht(ams Nag not be compressed to cause reductions in the amu-sectiorhul area of the duce. 3. Joints and samm of duet systems and their camponerim shall net be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and dawbands. 4. Exhaust fan systems have back stairs or automatic dampen. S. Gravity vmtilatingsYstaa seting conditioned space havecither automatic Of madly accessible, manually operated dampen. •'' 1. 8. prohectlem of loculation. Insulation shall be protected limo damage, including that du: m suafight. ' mmistwe, a4ulpraeat maintenance. and wind but not lusted to the following: insulation exposed to ,ratter shall be Nimble for service viee e.g.. protected by aluminum, sheet mmW, painted anves, a p W de cava. Cellular foam insulation shall be protected as above or painted with a eoagog that is § 114: Pool mad Spa Heating Systems and Equipment. 1 System is certified with 78%thareal emciency, oo-od switch, weatharproof operating instructions, oo clectr c resistance hating and an pilot light. NK 2. System is i isu8ed with: A. At last 36' of pipe between filter and hater for future anlu heating. b. Cava for oudoa pools or outdoor spa. 3. Pool system has dueciioal inlets and ■ eimuhtion pump time switch. §IIs: Gu fund a naW auoa"s. pmt harem, spa harm or household cooking appli;aes have no _,—.–... ....h......wwm:•n,.w whh runt < 1 SO R §118(0: Cool Rmf mterial meet specired criteria §I SO(k)I.: Luminance for geoa it lighting in kitchms shall have tamps with an effiacy 01`40 lumaa'Avan or greater fa general lighting In kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitehm. § I30(k)2.: Roams with a Nowa or bathtub must have either at least one luminaire with lamps with an efficacy of4o lunicturwau a greats witched at the are== to the mom a one of the altereal va to this mquiraircat allowed in § Is0(k)2.; and incandctcent massed ceiling 6xtures am IC (insulation Cover) CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 Project Address........ 78680 Avenida La Jarita •••'••• --------------------- Assembly La Quint& •v6.01• 1 I Documentation Author... Dawne Carson ••••'•• I Building Permit # I U -factor Location/Comments ------- ------------------ Energy Management Group, Inc. I I R-13 69-115 Ramon Rd., #F1364 I Plan Check / Date 1 0.088 Cathedral City, CA 92234 1 I { R-21 760-674-8280 1 Field Check/ Date I I� Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File-RIUWF Wth-CTZ15S92 Program -FORM CF -1R I I User#-MP0999 User -Energy Management Group, ------------------------------------------------------------------------------- Run -78680 Avenida La Jarita 1 R-0 GENERAL INFORMATION S1abEdge Conditioned Floor Area..... 210 of Building Type.............. Single Family Detached Construction Type ......... Addition Alone Building Front Orientation. Front Facing 180 deg (S) Number of Dwelling Units... 0.09 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 19 8 of floor area Average Glazing U -factor... 0.4 Btu/hr-af-F Average Glazing SHGC....... 0.35 Average Ceiling Height..... 8 ft FENESTRATION ------------ Over- Area U- Exterior hang/ Orientation (of) Factor SHGC Shading Fins Location/ Comments ---------------- ----- ------ -------------- ----- ---------- Door Front (S) 40.0 0.400 0.350 Standard Yes Vinyl/Wood Patio Door Low CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 MICROPA86 v6.01 File-RKHUFF Nth-CTZ15392 Program -FORM CF -1R 1 User#-M3?0999 User -Energy Management Group, Run -78680 Avenida La Jarita 1 ------------------------------------------------------------------------------ SLAB SURFACES ------------- Area Slab Type (of) ---------------- ------ Standard Slab 210 BUILDING SHELL INSULATION Component Frame ------------------------- Cavity Sheathing Total Assembly Type Type R -value -------- R -value -------- R -value ------- U -factor Location/Comments ------- ------------------ ------------ Wall ------- Wood R-13 R-0 R-13 0.088 Wall Wood R-21 R-0 R-21 0.059 Roof Wood R-11 R-27 R-36 0.025 Attic Door None R-0 R-0 R-0 0.330 Solid Wood S1abEdge None R-0 R-0 F2-0.760 To Outside SlabEdge None R-0 R-0 F2-0.510 To garage FENESTRATION ------------ Over- Area U- Exterior hang/ Orientation (of) Factor SHGC Shading Fins Location/ Comments ---------------- ----- ------ -------------- ----- ---------- Door Front (S) 40.0 0.400 0.350 Standard Yes Vinyl/Wood Patio Door Low CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 MICROPA86 v6.01 File-RKHUFF Nth-CTZ15392 Program -FORM CF -1R 1 User#-M3?0999 User -Energy Management Group, Run -78680 Avenida La Jarita 1 ------------------------------------------------------------------------------ SLAB SURFACES ------------- Area Slab Type (of) ---------------- ------ Standard Slab 210 REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance ,specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is .$) witted for a single building plan to be built in multiple orientations, any ;shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.:.: Sherri i Ron Huff Company. Owners 'Address. 78680 Avenida La Jarita La Quints, CA. 92253 Phone... (760)771-1260 License. Name.... Dawne Carson Company. Energy Management Group, Inc. Address. 69-115 Ramon Rd., #F1364 Cathedral City, CA 92234 Phone... 760-674-8280 Signed.. Signed. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) (date) Certified Energy Analyst N'NM Gerson R &844.224 r r CADEC CaWwJo Aoododon of Djklr,9 E, a Cm uMonb CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY HVAC SYSTEMS ------------ Refrigerant Tested ACCA .Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency ------------ Airflow Location ------- ----------- R -value Leakage ------- ------- D ------ Type ---------- '----------- --mace 0.800 AFUE n/a Attic R-4.2 No No Setback x3plit 10.00 SEER No Attic R-4.2 No No Setback REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance ,specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is .$) witted for a single building plan to be built in multiple orientations, any ;shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.:.: Sherri i Ron Huff Company. Owners 'Address. 78680 Avenida La Jarita La Quints, CA. 92253 Phone... (760)771-1260 License. Name.... Dawne Carson Company. Energy Management Group, Inc. Address. 69-115 Ramon Rd., #F1364 Cathedral City, CA 92234 Phone... 760-674-8280 Signed.. Signed. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) (date) Certified Energy Analyst N'NM Gerson R &844.224 r r CADEC CaWwJo Aoododon of Djklr,9 E, a Cm uMonb CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY TABLE OF CONTENTS TOC 4 Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 Project Address........ 78680 Avenida La Jarita ******* --------------------- La Quinta *v6.01* I I Documentation Author..'. Dawne Carsen ******* I Building Permit # Energy Management Group, Inc. I I 69-115 Ramon Rd., #F1364 I Plan Check / Date I Cathedral City, CA 92234 I I 760-674-8280 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-RKHUFF Wth-CTZ15S92 Program -TOC I I User#-MP0999 User -Energy Management Group, Run -78680 Avenida La Jarita I -------------------------------------------------------------------------------- TABLE OF CONTENTS ----------------- Report Page FORM CF -1R ................ 1 FORM MF -1R ................ 3 FORM C -2R ................. 6 HVAC SIZING ............... 9 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 Project Address........ 78680 Avenida La Jarita ******* --------------------- La Quinta *v6.01* I I Documentation Author... Dawne Carsen ******* I Building Permit # Energy Management Group, Inc. I 69-115 Ramon Rd., #F1364 I Plan Check / Date I Cathedral City, CA 92234 I I 760-674-8280 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-PJUMF Wth-CTZ15S92 Program -FORM CF -1R I User#-MP0999 User -Energy Management Group, Run -78680 Avenida La Jarita I ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area .....210 sf Building Type .............: Single Family Detached Construction Type ......... Addition Alone Building Front Orientation. Front Facing 180 deg (S) Number of Dwelling Units... 0.09 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 19 8 of floor area Average Glazing U -factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.35 Average Ceiling Height..... 8 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type ------------ Type R -value R -value R -value U -factor Location/Comments Wall ------- Wood -------- R-13 -------- R-0 ------- R-13 ------- ------------------------ 0.088 Wall Wood R-21 R-0 R-21 0.059 Roof Wood R-11 R-27 R-38 0.025 Attic Door None R-0 R-0 R-0 0.330 Solid Wood S1abEdge None R-0 R-0 F2=0.760 To Outside SlabEdge None R-0 R-0 F2=0.510 To garage FENESTRATION ------------ Over- Area U- Exterior hang/ Orientation (sf) Factor SHGC Shading Fins Location/Comments ---------------- ----- ------ -------------- ----- -------------------------- Door Front (S) 40.0 0.400 0.350 Standard Yes Vinyl/Wood Patio Door Low CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 I MICROPAS6 v6.01 File-RKHUFF Wth-CTZ15S92 Program -FORM CF -1R I User#-MP0999 User -Energy Management Group, Run -78680 Avenida La Jarita I ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 210 REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Sherri 6 Ron Huff HVAC SYSTEMS Dawne Carsen Company. Owners Company. ------------ Refrigerant Tested ACCA 78680 Avenida La Jarita Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type ------------ Efficiency ------------ Airflow Location R -value ------------------------- Leakage D Type Furnace 0.800 AFUE n/a Attic R-4.2, ------- No ------ No ---------- Setback ACSplit 10.00 SEER No Attic R-4.2 No No Setback REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Sherri 6 Ron Huff Name.... Dawne Carsen Company. Owners Company. Energy Management Group, Inc. Address. 78680 Avenida La Jarita Address. 69-115 Ramon Rd., #F1364 La Quinta, CA 92253 Cathedral City, CA 92234 Phone... (760)771-1260 Phone... 760-674-8280 License. Signed.. Signed.. (date) (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) Certified Energy Analyst Nvis CW&M R WB&224 rr rr CABEC CWbmic Auoda*,n of i Wkv Energy C.ombom MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF-lR Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 Project Address........ 78680 Avenida La Jarita ******* --------------------- La Quinta *v6.01* I I Documentation Author... Dawne Carsen ******* I Building Permit # Energy Management Group, Inc. I I 69-115 Ramon Rd., #F1364 I Plan Check / Date I Cathedral City, CA 92234 1 I 760-674-8280 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File-RKHUFF Wth-CTZ15S92 Program -FORM MF -1R 1 I User#-MP0999 User -Energy Management Group, Run -78680 Avenida La Jarita I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturer's labeled R -Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 4 MF -1R Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 I MICROPAS6 v6.01 File-RKHUFF Wth-CTZ15S92 Program -FORM MF -1R I I User#-MP0999 User -Energy Management Group, Run -78680 Avenida La Jarita I ------------------------------------------------------------------------------- b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design- Enforce- er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the'Commission. 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Setback thermostat on all applicable heating and/or cooling systems. 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sectons 601, 603, and 604, and standard 6-3; ducts insulated to a mininmm installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned.air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber addhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -1R Project Title .......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 MICROPAS6 v6.01 File-RKHUFF Wth-CTZ15S92 Program -FORM MF -1R I User#-MP0999 User -Energy Management Group, Run -78680 Avenida La Jarita ------------------------------------------------------------------------------- resistance heating and no pilot light. 2. System is installed with: a. At least,36 inches of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr). LIGHTING MEASURES ----------------- Design- Enforce- ment 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. El COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 Project Address......... 78680 Avenida La Jarita ******* --------------------- La Quinta *v6.01* I I Documentation Author... Dawne Carsen ******* I Building Permit # I Energy Management Group, Inc. I I 69-115 Ramon Rd., #F1364 I Plan Check / Date I Cathedral City, CA 92234 I I 760-674-8280 ( Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File-RKHUFF Wth-CTZ15S92 Program -FORM C -2R I I User#-MP0.999 User -Energy Management Group, Run -78680 Avenida La Jarita I ------------------------------------------------------------------------------- = _ NICROPAS6 ENERGY USE SUMMARY a = Energy Use ------------------------- Standard Proposed Compliance = _ (kBtu/sf-yr) _----------------------- Design ---------- Design ---------- Margin = _ Space Heating.......... 8.98 6.43 -------- _ 2.55 = = Space Cooling...... _ .. 61.68 -------- 63.96 -2.28 = = Total 70.66 -------- 70.39 -------- _ 0.27 = _ *** Water Heating not calculated INFORMATION Conditioned Floor Area.:... 210 sf Building Type .............. Single Family Detached Construction Type ......... Addition Alone Building Front Orientation. Front Facing 180 deg (S) Number of Dwelling Units... 0.09 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 1680 cf 210 sf 19A of floor area 0.4 Btu/hr-sf-F 0.35 8 ft COMPUTER METHOD SUBOOM Page 7 C -2R Project Title.......... 78680 Avenida;La Jarita Date..01/26/02 20:05:29 I MICROPAS6 v6.01 File-RRHUFF Wth-CTZ15S92 Program -FORM C -2R I User#-MP0999 User -Energy Management Group, Run -78680 Avenida La Jarita ------------------------------ ------------------------------------------------ BUILDING ZONE INFORMATION Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (of) Units itioned Type (ft) (sf) Credit HOUSE R-val ----- Azm Tilt --- ---- Gains Residence 210 1680 0.09 Yes Setback 2.0 Standard No OPAQUE SURFACES PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- HOUSE - New 7 S1abEdge 31 0.760 R-0 No To Outside 8 SlabEdge 31 0.510 R-0 No To garage t FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ HOUSE - New 1 Door.Front (S) 40.0 0.400 0.350 180 90 Standard Vinyl/Wood Patio Door Lo OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Wdth Hgth Dpth Eght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- HOUSE - New 1 Door 40.0 n/a 6.67 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a Area U- Insul Act, Solar Form 3 Location/ Surface -------------- (sf) ------ factor ----- R-val ----- Azm Tilt --- ---- Gains Reference Comments HOUSE - New ----- ------------ ---------------- 1 Wall 42 0•.088 13 180 90 Yes W.13.2X4.16 2 Wall 147 0.088 13 270 90 Yes W.13.2X4.16 3 Wall 82 0.088 13 0 90 No W.13.2X4.16 4 Wall 164 0.059 21 90 90 No W.21.2X6.16 5 Roof 210 0.025 38 180 19 Yes R.38.2X4.24 Attic 6 Door 17 0.330 0 270 90 Yes None Solid Wood PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- HOUSE - New 7 S1abEdge 31 0.760 R-0 No To Outside 8 SlabEdge 31 0.510 R-0 No To garage t FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ HOUSE - New 1 Door.Front (S) 40.0 0.400 0.350 180 90 Standard Vinyl/Wood Patio Door Lo OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Wdth Hgth Dpth Eght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- HOUSE - New 1 Door 40.0 n/a 6.67 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a f 1 COMPUTER METHOD SUMMARY Page 8 C -2R Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 I MICROPAS6 v6.01 File-RKHUFF Wth-CTZ15S92 Program -FORM C -2R I I User#-MP0999 User -Energy Management Group, Run -78680 Avenida La Jarita ------------------------------------------------------------------------------- SLAB SURFACES Area Slab Type (sf) HOUSE Standard Slab 210 HVAC SYSTEMS ------------- Refrigerant Tested ACCA System Minimum Charge and ;..Duct Duct Duct Manual Duct Type Efficiency Airflow Location ---------------- R. -value Leakage D Eff HOUSE ------- --------- -------- ---- Furnace 0.800 AFUE n/a Attic R-4.2 No No 0.815 ACSplit 10.00 SEER No Attic R-4.2 No No 0.703 REMARKS .:, HVAC SIZING Page 9 HVAC Project Title.......... 78680 Avenida La Jarita Date..01/26/02 20:05:29 Project Address........ 78680 Avenida La Jarita ******* --------------------- La Quinta *v6.01* I Documentation Author... Dawne Carsen ******* I Building Permit # I Energy Management Group, Inc. I I 69-115 Ramon Rd., #F1364 I Plan Check / Date Cathedral City, CA 92234 I I 760-674-8280 I Field Check/ Date Climate Zone....... .. 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File-RKHUFF Wth-CTZ15S92 Program -HVAC SIZING I User#-MP0999 User -Energy Management Group, Run -78680 Avenida La Jarita ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area...'...... .... 210 sf Volume ..................... 1680 cf Front Orientation.......... Front Facing 180 deg (S) Sizing Location............ LA QUINTA Latitude ................... 33.8 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range ............... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Description Opaque Conduction Glazing Conduction Glazing Solar Infiltration. Internal Gain Ducts........ Sensible Load Latent Load.. Min;—ma Total Load 5150 Cooling (Btuh) 1410 544 534 587 189 326 3591 718 4309 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating -------------------- (Btuh) and Solar...... ----------- 3186 ............... 608 ..... ............. n/a .................... 887 .................... n/a .................... 468 .... .............. 5150 .................... n/a Opaque Conduction Glazing Conduction Glazing Solar Infiltration. Internal Gain Ducts........ Sensible Load Latent Load.. Min;—ma Total Load 5150 Cooling (Btuh) 1410 544 534 587 189 326 3591 718 4309 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment.