Loading...
BRES2014-1138t r• 78-495 CALLE TAMPICO` LA QUINTA, CALIFORNIA 92253 .Tdy 4 4 Qumlk COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2014-1138 Property Address: 47645 VIA MONTANA APN: 643120050 Application Description: REMODEL KITCHEN, WINDOWS AND DOORS Property Zoning: Application Valuation: $35,000.00 Applicant: ANDRZEJ WEBER 2276 VIA ALBA PALM DESERT, CA 92260 CID ofLOP IE INDEPAFTMENI COMMUNITY ; LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: Pte:/ZZZ4 Contractor: OWNER -BUILDER DECLARATION ereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Divisio of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant f a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/18/2014 .Owner: FRANK RASADA 1115 MADISON ST NE # 816 SALEM, OR 92253 Contractor: MIKE HART 42935 VIRGINIA AVE PALM DESERT, CA (760)333-1517 Llc. No.: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith Fmply with those provisions. ZIZ24 pate: d V Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null'and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned prop rty for.inspection purposes. gate: /ZSignature (Applicant or Agent): I/ &z4oe 0 FINANCIAL DESCRIPTIONax•ACCOUNTL -QTY AMOUNT `,7' r , , PAID, `PAID DATE. HOURLY PLAN CHECK - YES 101-0000-42600 2.5 $175.00 $0.00 PAID BY " ` "y` -" a r 'METHOD'+ �' ;� k' z y RECEIPT # _ '• „a :''. CHECK,# ` CLTD BY Total Paid for BLDG CITY STAFF - PER HOUR: $175.00 $0.00 x 3 DESCRIPTION` <` { `' x - A COUN QTY _- AMOUNT r = <. °PAID - `" PAID DAT BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 _r. PAID BY �, , " .. " METNOD;•.' RECEIPT # , -.CHECK # t . CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00 ' ADESCRIPTIOW ; s ar • .. �`': ACCOUNT .QTY , ' AMOUNT_.`. `' t r .PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 x - PAID;BY 5 METHOD RECEIPT'# S CHECK # - CLTf) BY µ x :<; DESCRIPTION {,', ," 3ACCOUNT�• K ,r'. rs QTY AMOUNT ' ` <PAID; ' PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $0.00 .`PAID BY 7 METHOD`rte ' ' ` +RECEIPT; # `CHECK'#; CLTD BY Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00 _ 'DESCRIPTION -' ;, 4 ACCOUNT r QTY ` AMOUNT•:=` '< _�.�PAID``'" - PAID DATE` EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 F_`'.PAID,FBY M+' `<, ,' METHOD : + rX RECEIPT #` '` CHECK# CLTD;BY COUNTS' . CfTY }K AMOUNT n,r; PAID ! PAID•DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 r`i 7 PAIDZY,.=` METHOD f RECEIPT#gym.. ECK#� "CLTD BY, Total Paid for MECHANICAL: $16.92 $0.00 u.Y DESCRIPT.ION ti + ` �« .'ACCOUNT '"+QTY a y IAMOUNT PAID '' PAID«DATE FIXTURE/TRAP 101-0000-42401 0 $36.27 $0.00 , METHOD a - .k'# RECEIPT,# xt ' .r .CHECK # CLTD BY;. DESCRIPTION` L,'*ACCOUNT�r `` + t #-QTY ' "s .AMOUNT Al PAID:DATE FIXTURE/TRAP PC 101-0000-42600 0 $36.27 $0.00 ? , '+PAID BY'-"':"METHOD'.','! 3�'tZRECEIPT4f ^ +;CHECK# CLTD BY,, ` DESCRTTION=} + ACCOUNT<f ' J ;{ `'QTY `Wit' `AMOUNT ="' P' ` rPAID� ;PAID DATE; GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $12.09 $0.00 �• ',t=; `PAID, BY , µ .' t x xr ; _� `G METHODI'C LTD BY i • `` ;DESCRIPTION ' ;• °AC_COUNT 4Q ' ` 'AMOUNT, "'4� PAID t+' PAID DATE y ._ . , GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $24.17 $0.00 METHOD' RECEIPT~# q a "µCHECK# ;CLTD BY;" fy. a A"` 4 „ , s; k Total Paid for PLUMBING FEES: $108.80 $0.00 "ACCOUNT r QTY x' AMOUNT PAID'"" -PAID DATE REMODEL, EA ADDITIONAL 500 SF 101-0000-42400. 0 $43.50 $0.00 `PAID BY "; :.: "' METHOD' RECEIPT:# "CHECK #, CLTDBY_' ` r.,."DESCRIPTION ',;`t' ;" ::_` . i ',ACCOUNT„ �'''�a QTY: le =AMOUNT t � :PAID ;PAID DATE ,. REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $34.80 $0.00 ''PAID:BY' e° `' ; - '`7 4 ' .c1L 1� ` w� <+S RECEIPT..# t � +' : CHECK# CLTD BY ? .METHOD , ..... DESCRIPTION f tt :: " �' 'x , E ;ACCOUNT ,=F - ; .r i"*QTYa 17 : � AMOUNT" ,:,PAID PAID DATE REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 BY i.METHODx ' RECEIPT#�^ ; CHECK #- CLTDBY.• DESCRIPTION wr '3, '' T �`' r :ACCOUNTS 'tFt s, `QTY AMOUNT = , PAID,,' - PAID DATE{ , REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $0.00 7. .PAID BYE, 3,.°� r'... 'METHOD �� : r RECEIP,T # . k;� . CHECK #•. '. CLTD."BY •, x S;s X Total Paid for REMODEL: $262.49 $0.00 DESCRIPTION ; ; " ACCOUNT ,M QTY 'r�'AMOUNT ,PAID 'PAID DATE' SMI - RESIDENTIAL 101-0000-20308 0 $4.55 $0.00 .i`,',PAID.BY :'° MF`'�, METHOD" r a`RECEIPTa# CHECK# r CLTD BY z Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $4.55 $0.00 r.^ "DESCRIPTION "t h " ,,,.,ACCOUNT', ,"` ,"QTY" .x r'AMOUNT `'' PAID'' PAID DATE" DOOR/WINDOW, REPLACE FIRST 7 101-0000-42400 0 $60.91 $0.00 - PAID BY METHOD i RECEIPT # 3 CHECK # CLTD BY a.' DESCRIPTION', = ,A000UNT ". Q N AMOUNT .,� a^ PAID PAID "DATE' ry }t t e r A yy r„ DOOR/WINDOW, REPLACE, FIRST 7 PC 101-0000-42600 0 $110.22 $0.00 PAID'' METHOD �`��?`'' `"nytRECEIPT;# r �CHECK�#i� _ CLTD BYE. Total Paid forWINDOW/SLIDING GLASS DOOR/FENESTRATION: $171.13 $0.00 TOTALS:00 Description: REMODEL KITCHEN, WINDOWS AND DOORS r. . � Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED ADDITIONAL SITES Applied: 10/20/2014 SKH Approved: Parcel No: 643120050 Site Address: 47645 VIA MONTANA LA QUINTACA 92253, Subdivision: TR 261S2 Block: Lot: 278 CHRONOLOGY issued:' Lot Scl Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $35,000.00 Occupancy Type: Construction Type: Expired: FROM CONSULTANT Details: FULL KITCHEN REMODEL WITH BUTLER'S PANTRY. NEW SLIDING DOORS AND WINDOWS. 11/5/2014 . . - Printed: Thursday, December 1lZOz44kZzlNPN' 1cf4 —____-- ---- ' ` r. . � ^ ` . ^ . . - Printed: Thursday, December 1lZOz44kZzlNPN' 1cf4 —____-- ---- ' ` ADDITIONAL SITES CHRONOLOGY YTYPE PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 11/5/2014 11/5/2014 STRUC APPROVABLE 11/5 RECEIVED PLAN CHECK COMMENTS FROM CONSULTANT PHILIP JUAREZ 12/15/2014 PLANS RECIEVED FROM YOUNG APPROVED. RECEIVED PLAN CHECK PICKED UP STEPHANIE KHATAMI 11/6/2014 11/6/2014 PICKED UP BY ANDRES WEBER (SK) PLAN CHECK SUBMITTAL KAY HENSEL 10/20/2014 RECEIVED PLAN CHECK SUBMITTAL . STEPHANIE KHATAMI 1 2/1/20.14 12/1/2014 RECEIVED SENT TO PLAN CHECK KAY HENSEL 10/20/2014 10/20/2014 STRUC TO YOUNG, DUE 11/3/14 CONSULTANT . . - Printed: Thursday, December 1lZOz44kZzlNPN' 1cf4 —____-- ---- ' ` TELEPHONE CALL ARMEN ALTOUNIAN 11/6/2014 11/6/2014 CALLED ANDRZEJ WEBER AND HE WI LL PICK UP THE PLANS. TELEPHONE CALL ARMEN ALTOUNIAN 12/16/2014 12/16/2014 PLANS APPROVED AND READY FOR PICK UP. CONDITIONS YES CONTACTS Total Paid forBLDG CITY STAFF - PER HOUR. $175.00 $0.00 BSAS SB1473 FEE 101-0000-20306 $2.00 STATEf— APPLICANT ANDRZEJ WEBER 2276 VIA ALBA PALM DESERT CA. 92260 (760)340-3002 RESIDENTIAL, FIRST 101-0000-42403 CONTRACTOR MIKE HART 42935 VIRGINIA AVE PALM DESERT CA (760)340-3002 OWNER FRANK RASADA 1115 MADISON ST NE # 816 SALEM OR 92253 (760)346-3002' FINANCIAL INFORMATION IL HOURLY PLAN CHECK - 101-0000-42600 2.5 $175.00 $0.00 YES Total Paid forBLDG CITY STAFF - PER HOUR. $175.00 $0.00 BSAS SB1473 FEE 101-0000-20306 $2.00 Total Paid forBUILDING STANDARDS ADMINISTRATION RESIDENTIAL, FIRST 101-0000-42403 0 $14S.03 $0.00 RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $0.00 1,OOOSF, PC Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00 EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0 00 Total Paid forMECHANICAL: $16.92 $0.00 FIXTURE/TRAP 101-0000-42401 0 $36.27 $0.00 ' Printed: Thursday, December 18,20144:21:08PN Zcf4 ' ' CRW.~'~.. ` ' ~ ,OF Printed: Thursday, December 18, 2014 4:21:08 PM 3of4 CRSYSTEMS 7- 7-7 LT6, DESCRIPTION UNi�',�' AMOUNT PA D PAID DATE, RECEIPT#' .'nCHECK.# METHOD, PAID FIXTURE/TRAP PC 101-0000-42600 0 $36.27 $0.00 GAS SYSTEM, 1-4 101-0000-42401 0 $12.09 $0.,00 OUTLETS GAS SYSTEM, 1-4. 101-0000-426000 $24.17 $0.00 OUTLETS PC Total Paid for PLUMBING FEES: $108.80 $0.00 REMODEL, EA 101-0000-42400 0 $43.50. $0.00 ADDITIONAL 500 SF REMODEL, EA 101-0000-42600 0 $34.80 $0.00 ADDITIONAL 500 SF PC REMODEL, FIRST 100 SF1 101-0000-42400 0, $49.31 $0.00 REMODEL, FIRST 500 SF 101-0000-42600 0 $134.88 $0.00 PC Total Paid for REMODEL: $262.49 $0.00 SMI - RESIDENTIAL 101-0000-20308 0 $4.55 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SM!$4.55 $0.00 DOOR/WINDOW, 101-0000-42400 0 $60.91 $0.00 REPLACE FIRST 7 DOOR/WINDOW, 101-0000-42600 0 $110.22 $0.00 REPLACE, FIRST 7 PC ti 'Total Paid forWINDOW/SLIDING GLASS $171.13 $0.00 DOOR/FENESTRATION: TOTALS: $933.78 $0.00 Printed: Thursday, December 18, 2014 4:21:08 PM 3of4 CRSYSTEMS Printed: Thursday, December 18, 2014 4:21:08 PM 4of4 yPATHNAME, T£ SUBOIR rETRAKIT,ENABLED.; PARENT PROJECTS 0 REVIEWS %Av;REVIEW TYPE= a .:: "9•: wii - - ,,-- -__ REVIEWER • s=. .� �.�,`?r"' -SENT-DATE -- �_«isr ,� .,_ -DUE DATE " ,RETURNEDti` ; �; _ �.: �, z DATE �?�� STATUS se :,c. S d,;- x.• . �„w�_�..�z�.:..,.:�." � . a rrc: 'i*r s� C,3r, .-+ *� �.�.-..,...> •: cr .«r:+�`-�3 •kt';NOTES...,: ;":fi �1" ..'..' tt•7+^ a.o i"!: x ; `�. .��,; -T: ° s;_ •tea � •�:�.•� NON-STRUCTURAL ARMEN ALTOUNIAN 10/20/2014 11/3/2014 10/21/2014 REVISIONS REQUIRED 1ST PLAN CHECK RFC READY FOR CORRECTIONS STRUCTURAL JOHN THOMPSON 10/20/2014 11/3/2014 APPROVED - k- STRUC APPROVED 11/5 STRUCTURAL BRONZ YOUNG 12/1/2014 12/14/2014 12/16/2014, APPROVED. 2ND PLAN CHECK. APPROVED NON-STRUCTURAL ARMEN ALTOUNIAN 12/1/2014. 12/14/2014 12/1/2014 `- APPROVED 2ND PLAN CHECK APPROVED Printed: Thursday, December 18, 2014 4:21:08 PM 4of4 • COTW.,YSTEMS yPATHNAME, T£ SUBOIR rETRAKIT,ENABLED.; 47-645 VIA MONTANA.docx 0 • COTW.,YSTEMS Bin # ..o City of La Quinta Building 8F Safety Division P.O. Box 1504, 78-495 Calle Tampico. La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # � � Zjc>44t_A Project Address: "76A l�°•�l 7 WA A m osl*N Owner's Name: zr-f �' /��'�(� t2,10 M A. P. Number: —' ^ �So Address: a Legal Description: 'C, OT' 2� 6 Z e T6 City, ST, Zip: ntract Co r• o . I Tc h nc: p Address: Project Description: rr G`4.�`� r���✓\ City, ST, Zip: p �� �. J (/J V .v p•� IOW Telephone: J ( � Q- D 1.0" State Lie. #: City Lie. #. — Arch., Engr., Designer: Address: Z� (��^ ��� MAS City, ST, Zip: p �' l Telephone: k 3t-0, 3 On 2 ;:;t::;;::.;;:;:.: Construction Type: Occupancy: 3 V / State Lie- #: C i2 �j >? � :•.'^Q:! iii ��+.::i �?:v:.::? i:Y•iF•:::•: ...... . Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.: �—' # Stories: 1 #Units: l Telephone #,of Contact Person: Fye �,� 00'z_ Estimated Value of Project. APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets 3 Plan Check submitted �Q Item Amount Structural Calcs. Reviewed, ready for corrections t 6 Plan Cluck Deposit Truss Cala. Called Contact Person! I/ Plan Check Balance. Title 24 Calcs. Plans picked up ANtile, . Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for correction /issue . `2J1r Electrical Subcontactor List Called Contact Person Plumbing Grant Decd Plans picked up S.M.I. Ii.O.A. Approval Plans resubmitted Grading IN IiOUSE:- '`d Review, ready for corrcctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 0 T 2 0 2.014 CITY OF LA QUINTA COMMUNITY DEVELOPMENT To: Attn: 84744S VIA M -4w &,oYTANp Pi s X14- 118 77-682 Country Club Dr. Ste.. B, Palm Desert, CA 92211 ph. (760)'772-5107 fax (760) 345-7620 Letter of Transmittal City of La Quinta Today's Date: 11`-4-14 78-495 Calle Tampico City Due Date: 11-3-14 La Quinta, CA 92253 Project Address: 47-645 Via Montana Kay Plan Check #: BRES 2014-1138 Submittal: ® 1st ❑ 4th We are forwarding: Includes: # Of Copies: 1 A ® By Messenger 4 Descriptions: Structural Plans ❑ 2nd ❑ -55th ❑ V ❑ Other: ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Copies: Structural Calculations Truss Calculations Floor .and Roof Soils Report Structural Comment List Redlined Structural Plans Redlined Structural Calcs Redlined Truss Calcs Redlined Soils Reports ❑ Revised Structural Plans ❑ Revised Struct. Calcs ❑ Revised Truss ❑ Revised Soils Report ❑ Approved Structural Plans ❑ Approved Structural Calcs ❑ Approved Truss Calcs ❑ Approved Soils Report ❑ Other: Comments: Structural content is approvable. �\ I L � lie V L By: Kathryn Samuels Palm Desert Office: ® (760) 772-5107 Other: ❑ If you have any questions, please call. NOVU Time = 1.5 HR iii vi b= QU This Material Sent for: COMMUNITYDEVELC. ❑ Your Files ® Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ By: Kathryn Samuels Palm Desert Office: ® (760) 772-5107 Other: ❑ The Management Trust MONARCH GROUP DIVISION September 22, 2014 FRANK & MARY RASADA 47645 VIA MONTANA LA QUINTA, CA 92253 RE: Architectural Submittal for 47645 VIA MONTANA 278 Account #659797 Dear Homeowner. The Architectural Review Committee for LAKE LA QUINTA has reviewed and APPROVED your architectural submittal for the installation of replacing the rear sliding doors, add installation of a new window for the kitchen, and remove the center post in rear patio per the plans submitted. ARC approval of plans shall not constitute a representation, warranty, or guarantee that such plans and specifications comply with engineering design practices or zoning and building ordinances, or other governmental agency regulations or restrictions. The ARC shall not be responsible for reviewing, nor shall its approval of any plans or design, be deemed approved from the standpoint of structural safety or conformance with building or other codes. By approving such plans and specifications, neither the ARC, the Members thereof, the Association, any Member thereof, their Board of Directors, any Members thereof, or the Declarant assumes any liability or responsibility therefore or for any defect in the construction or improvement from such plans or specifications. As provided in the. CC&R's neither the ARC, the Association, the Board of Directors or the Association or any Members thereof, not the Declarant or Developer shall be liable to any Member, Owner, Occupant, or other person or entity for any damage, loss or prejudice suffered or claimed on account of (1) the approval or disapproval of any plans, drawings, or specifications, whether or not'defective, or (2) the construction or performance of any work whether or not pursuant to the approved plans, drawings, or specifications. Your patience and cooperation with the architectural review process is appreciated. If you have any questions, please contact the association at (760) 776-5100, Extension 333. . c Sincerely, On behalf of the LAKE lA QUINTA Architectural Review Committee Wendy Coyne The Management Trust - Monarch Group Division Enclosures (1) cc: Board of Directors Unit File 39755 Berkey Drive, Suite A, Palm Desert, CA 92211 AN EMPLOYEE OWNED CONIPAM' PH: 760.776.5100 FAX: 760.776.5111 www.managementtrust.com ear BUILDING ENERGY ANALYSIS REPORT PROJECT: Mr. & Mrs. Frank:& Mary Rasada Residential Remodel 47 645 Via Montana, Lake La Quinta La Quinta, CA 92253. Project Designer: Andrzej W. Weber Architect 2276 Via Alba Palm Desert, CA 92260 760.340.3002 - Report Prepared by: Wayne Seward Bear Technologys 7774, Calle Mejor Carlsbad, CA 92009 760.635.2327 ' r INTA CITY OF LAQU DEPT.. Job Number: D Q BUILDING & SA FETYAppFiOVE® 14Q4020.3-2. DEC 0 2014 FOR CONSTR ION - Cl OF LA QUINTA Date:, COMMUNITY DEVELOPMENT DEPARTMENT DATE�BY 11/11/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. Ener Pro 6.3 by Ener Soft User Number: 5956 ID: 14Q4020.3-2 'TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 11 Form MF -1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 15 EnergyPro 6.3 by EnergySoft Job Number: ID: 14Q4020.3-2 User Number: 5956 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014 . Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml CF1 R -PRF -01 Page 1 of 8 GENERAL INFORMATION 01 Project Name Mr. & Mrs. Frank & Mary Rasada Residential Remodel 02 Calculation Description Title 24 Analysis 03 This building incorporates one or more Special Features shown below 03 Project Location 47 645 Via Montana, Lake La Quinta 04 CA City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 3013 15 Number of Zones 1 16 Slab Area (FT2) 3013 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) 0 21 Glazing Percentage (%) 15.2% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.33 2.07 0.26 11.2% Space Cooling 134.84 124.37 10.47 7.8% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 9.00 9.00 0..10+ l-'0 Photovoltaic Offset — 0.00 AV f TOTAL 146.17 135.44 1 , ' / I L_N i` � 1 �;3$/; /Ar hu V t FOR CONSTRUCTION DATE BY Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-1118:10:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Cool roof Cathedral Ceiling PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below, requre field verification by a certified HERS Rater. Building -level Verifications: — None — Cooling System Verifications: — None — HVAC Distribution System Verifications: — None — Domestic Hot Water System Verifications: — None = _ ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2)• 183.68 172.95 10.73 5.8% ` includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING FEATURE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type Number of Dwelling Zone Floor Area (ft2) Avg. Ceiling Height Number of Number of Water Project Name Conditioned Floor Area (sft) Units Number of Bedrooms Number of Zones Ventilation Cooling Systems Heating Systems Mr. & Mrs. Frank & Mary Rasada 3013 1 4 1 0 1 Residential Remodel ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Existing Residence Conditioned Res HVAC1 3013 10.2 DHW Sys 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-1118:10:48 N CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Mr. 8 Mrs. Frank 8 Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml CF1 R -PRF -01 Page 3 of 8 _x OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (f:2) Window and Door Tilt(deg Area (ft) ) Status Verified Existing Condition North Wall Existing Residence R-19 Wall 0 Right, 856.8 56 90" Existing No " East Wall Existing Residence R-19 Wall .90 Front 320.8 46.5 90 Existing No South Wall Existing Residence R-19 Wall 180 Left 856.8 77.8 90 Existing No West Wall Existing Residence R-19 Wall 270 Back 632.4 278 90 Existing No Roof 2 Existing Residence R-30 Roof Attic Existing Residence R-30 Roof 3013 198 Existing No (e) GarageWall North Garage Garage Ext Wall 0 Right 184.5 90 Existing No (e) GarageWall East Garage Garage Ext Wall 90 Front 279 174' 90 Existing No (e) GarageWall South Garage Garage Ext Wall 180 Left 184.5 90 Existing 'No IS Garage>>Existing Residence R-13 Wall 0.1 I 0.85 315 fi -, Existing No OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 06 07- 08 09 10 11 12 13 Radiant Barrier Cool Roof Status Verified Existing Condifion . Attic Attic Roof Cons 4 0.3 0.75 Roof Roof Framin No Verified Orientatio Area Skylight Roof Rise Roof Roof Reflectan ` Emmittan g Statu Existing Name Zone Type n (ft) Area (ft2) (x in 12) Pitch Tilt(deg) ce ce Factor s Condifion Roof Existing Residence R-30 Roof - specify - 198 0 4 0.33 18.43 0.1 0.85 0.1 Existin" No Cathedral 9 (e)GarageRoof Garage R-30 Roof -specify- 0 4 0.33 18.43• 0.1 I 0.85 0.1 Existin . No Cathedral ,608 g ATTIC 01 02 03 04 05 06 09 10 11 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condifion . Attic Attic Roof Cons 4 0.3 0.75 Yes Yes Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651' Report Generated at 2014-11-1118:10:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml CF1 R -PRF -01 Page 4 of 8 WINDOWS 01 02 03 01 02 03 04 05 06 07 08 09 10 11 Name Side of Building Width(ft Height Multiplie ) (ft) r Area (W) U -factor SHGC Exterior Shading Status Verified Existing Condition (e) IAL 1 North Wall - - 1 25.0 0.32 0.25 Insect Screen (default) Existing No (e)W-2 North Wall - - 1 6.0 0.32 0.25 Insect Screen (default) Existing No (e)W-3 North Wall - - 1 25.0 0.32 0.25 Insect Screen (default) Existing No (e)W-4 East Wall - - 1 19.0 0.32 0.25 Insect Screen (default) Existing No (e)W-6 East Wall - - 1 27.5 0.32 0.25 Insect Screen (default) Existing No (e)W-5 South Wall - - 1 19.0 0.32 0.25 Insect Screen (default) Existing No (e)W-7 South Wall - - 1 3.0 0.32 0.25 Insect Screen (default) Existing No (e)W-8 South Wall - - 1 3.0 0.32 0.25 Insect Screen (default) Existing No (e)W-9 South Wall - - 1 3.0 0.32 0.25 Insect Screen (default) Existing No (e)W-10 South Wall - - 1 25.0 0.32 0.25 Insect Screen (default) Existing No 56X46 FIXED GLASS WINDOW South Wall - - 1 24.8 0.32 0.25 Insect Screen (default) New N/A 120X80 SLIDING DOOR West Wall - - 1 96.0 0.32 0.25 Insect Screen (default) Altered N/A 80X80 SLIDING DOOR West Wall - - 1 64.0 0.32 0.25 Insect Screen (default) Altered N/A 80X80 SLIDING DOOR 2 West Wall - - 1 64.0 0.32 0.25 Insect Screen (default) I Altered N/A 120X46 FIXED GLASS WINDOW West Wall - - 1 54.0 1 0.30 0.22 Insect Screen (default) Altered N/A DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U -factor Status Verified Existing Condition (e)D-2 North Wall 48.0 0.50 Existing No (e)D-1 East Wall 50.0 0.50 Existing No NEW SIDE ENTRY DOOR 30X80 South Wall 24.0 0.50 Altered No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-1118:10:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Daterrime: 18:09, Tue, Nov 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml CF1 R -PRF -01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 Construction Name Surface Type Framing Total Cavity R -value Assembly Layers Zone Area (ft) 2x4 Top Chord of Roof Edge Insul. R -value Cavity/ Frame: no insul. /2x4 Top Chrd Attic Roof Cons Attic Roofs Truss @ 24 in. O.C. - no insulation - Roof Deck: Wood Siding/sheathing/decking 3013 261 - none - 0.8 • Roofing: Light Roof (Asphalt Shingle) Existing No • Inside Finish: Gypsum Board R-30 Roof Cathedral Cathedral Ceilings 2x12 @ 16 in. O.C. R 30 Cavity/Frame: R -30/2x12 • Roof Deck: Wood Siding/sheathing/decking • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board R-13 Wall Interior Walls 2x4 @ 16 in. O.C. R 13 Cavity/Frame: R -13/2x4 • Other Side Finish: Gypsum Board • Inside Finish: Gypsum Board R-30 Roof Attic Ceilings (below attic) 2x4 @ 24 in. O.C. R 30 Cavity/Frame: R-9.1 /2x4 • Over Floor Joists: R-20.9 insul. • Inside Finish: Gypsum Board R-19 Wall Exterior Walls 2x6 @ 16 in. O.C. R 19 Cavity/ Frame: R -19/2x6 • Exterior Finish: Wood Siding/sheathing/decking SLAB FLOORS 01 02 03 04 05 06 07 08 09 ' Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab Existing Residence 3013 261 - none - 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 Name Distribution Type Number of Heaters Solar Fraction (%) Status Verified Existing Condition DHW Sys 1 Standard 1 Annual Existing No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-1118:10:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml CF1 R -PRF -01 Page 6 of 8 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05" 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02 01 02 03 04 05 06 07 08" 09 Name Heating System Cooling System Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11.3 13 No No Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Res HVAC1 Other Heating and Heating. Yes Cooling Yes Air Distribution HVAC Fan 3013 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency. . Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11.3 13 No No N/A system Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-1118:10:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml CF1R-PRF-01 Page 7 of 8 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 08 Insulation Supply Duct Return Duct Verify Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 1 specified) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-1118:10:48 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Datefrime: 18:09, Tue, Nov 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml CF1 R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION. STATEMENT 1. 1,certify that this Certificate of Compliance documentation is accurate and complete: Documentation Author Name: Documentation Author Signature:�� cJ Wayne Seward Company: Signature Date: Bear Technologys 11/11/2014 LABEC carom, A. -WI -4 amd,g EMM CEA/HERS Certification Identification (If applicable): MEMM _ Address: 7774 Calle Mejor City/stateEa�lsbad, CA 92009 Phone: 760.635.2327 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance: 2.. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part -6 of the.California Code of Regulations. . Compliance the information r documents, 3. The building design features or system design features identified on this Certificate of are consistent with pro/ided on applicable compliance worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application/ Responsible Designer Name: Responsible Designer Signature: Andrzej W. Weber r Company: Date Signed: Andrzej W. Weber Architect ?"0. Address: License: 2276 Via Alba City/State/Zip: Phone: Palm Desert, CA 92260 760.340.3002 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-6S1 HERS Provider: Report Generated at 2014-11-1118:10:48 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Mr. & Mrs. Frank & Mary Rasada Resident Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 11111112014 Date Project Address 47 645 Via Montana, Lake La Quinta La California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,013 Addition 0 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Rafter R 30 198 Existing Roof Wood Framed Attic R 30 3,013 Cool Roof Existing Wall Wood Framed R 19 2,087 Existing Door Opaque Door no insulation 98 Existing Door Opaque Door no insulation 24 Altered Slab Unheated Slab -on -Grade no insulation 3,013 Perim = 261' Existing FENESTRATION Total Area: 458 Glazing Percentage: 15.2%1 New/Altered Average U -Factor: 0.32 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Right (N) 56.0 0.320 0.25 none none Bug Screen Existing Front (E) 46.5 0.320 0.25 none none Bug Screen Existing Left (S) 53.0 0.320 0.25 none none Bug Screen Existing Left (S) 24.8 0.320 0.25 none none Bug Screen New Rear (W) 224.0 0.320 0.25 none none Bug Screen Altered Rear (lM 54.0 0.300 0.22 none none Bug Screen Altered HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Res HVAC Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.3 by Ener Soft User Number: 5956 RunCode: 2014-11-11718:12:36 ID: 14Q4020.3-2 Pae 11 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MFA R Project Name Date Mr. & Mrs. Frank & Mary Rasada Residential Remodel 11111112014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Alterations insulation in wood -frame ceiling orequivalent U -factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§150.0(d): Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. 150.0 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is reater, is exempt from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is eq ui ed with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.0(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoft User Number: 5956 ID: 14Q4020.3-2 Page 12 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. & Mrs. Frank & Mary Rasada Residential Remodel 11111112014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.00)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components : A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A qas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. §150.0(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150.0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0 k 1C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). 150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number: 5956 ID: 14Q4020.3-2 Page 13 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MFA R Project Name Date Mr. & Mrs. Frank & Mary Rasada Residential Remodel 11111112014 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens shall meet the applicable requirements of §150.0(k). §150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f12 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9 130.0, 130.2, 130.4, 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.3 by EnergySoft User Number: 5956 ID: 14Q4020.3-2 Page 14 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. & Mrs. Frank & Mary Rasada Residential Remodel Date 11/11/2014 System Name Res HVAC Floor Area 3,013 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,793 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 24,000 35,589 3,656 680 33,265 Total Output Btuh 48,000 0 Output Btuh/s ft 15.9 3,018 2,363 Cooling System 0 0 Output perSystem 24,000 0 0 0 0 Total Output Btuh 48,000 0 3,656 0 Total Output Tons 4.0 3,018 2,363 Total Output Btuh/s ft 15.9 Total Output s ft/Ton 753.3 41,624 37,991 Air System CFM perSystem 1,050 HVAC EQUIPMENT SELECTION Airflow cfm 2,100 Standard Existing HVAC System 34,039 6,881 48,000 Airflow cfm/s ft 0.70 Airflow cfm/Ton 525.0 Total Adjusted System Output 34,039 6,881 48,000 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Outside Air % 0.0% Outside Air cfm/s ft 0,00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 IF Outside Air 0 cfm Supply Fan 2,100 cfm 67 OF 67 OF 115 OF Heating Coil 114 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 76162 Outside Air Ar 0 cfm 76162 OF OF 76 / 62 OF 55 / 54 OF Supply Fan Cooling Coil 56 ! 54 OF 2,100 cfm .... .... ....._...._... .. C��TY OF LA Q�,��NTA OOM mIq _ 31JI rDING & SAFETY DEP 75 / 62 OF A D 0 1. FOR CONSTRUCTION EnergyPro 6.3 by EnergySoft User Number: 5956 RunCode: 2014-11-11718:12:36 ;;,2: 14Q4020.3-2 Page 15 7 15