BRES2014-1138t
r•
78-495 CALLE TAMPICO`
LA QUINTA, CALIFORNIA 92253
.Tdy 4 4 Qumlk
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number:
BRES2014-1138
Property Address:
47645 VIA MONTANA
APN:
643120050
Application Description:
REMODEL KITCHEN, WINDOWS AND DOORS
Property Zoning:
Application Valuation:
$35,000.00
Applicant:
ANDRZEJ WEBER
2276 VIA ALBA
PALM DESERT, CA 92260
CID ofLOP IE INDEPAFTMENI
COMMUNITY ;
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.:
Pte:/ZZZ4 Contractor:
OWNER -BUILDER DECLARATION
ereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Divisio
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant f a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) 1, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
( 11, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(� I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 12/18/2014
.Owner:
FRANK RASADA
1115 MADISON ST NE # 816
SALEM, OR 92253
Contractor:
MIKE HART
42935 VIRGINIA AVE
PALM DESERT, CA
(760)333-1517
Llc. No.:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
Fmply with those provisions.
ZIZ24
pate: d V Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null'and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above-
mentioned prop rty for.inspection purposes.
gate: /ZSignature (Applicant or Agent):
I/ &z4oe
0
FINANCIAL
DESCRIPTIONax•ACCOUNTL
-QTY
AMOUNT `,7' r , , PAID, `PAID DATE.
HOURLY PLAN CHECK - YES 101-0000-42600
2.5
$175.00 $0.00
PAID BY " ` "y` -" a r 'METHOD'+ �' ;� k' z
y RECEIPT # _ '•
„a :''. CHECK,# ` CLTD BY
Total Paid for BLDG CITY STAFF - PER HOUR: $175.00 $0.00
x 3 DESCRIPTION` <` { `' x
- A COUN
QTY
_- AMOUNT r
= <. °PAID - `"
PAID DAT
BSAS SB1473 FEE
101-0000-20306
0
$2.00
$0.00
_r. PAID BY �, , "
.. " METNOD;•.'
RECEIPT # ,
-.CHECK # t .
CLTD BY
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00
' ADESCRIPTIOW ; s
ar • ..
�`': ACCOUNT
.QTY
, ' AMOUNT_.`. `'
t r .PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
$0.00
x - PAID;BY 5
METHOD
RECEIPT'# S
CHECK # -
CLTf) BY µ
x :<; DESCRIPTION {,', ,"
3ACCOUNT�• K ,r'. rs
QTY
AMOUNT '
` <PAID; '
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
$0.00
.`PAID BY 7
METHOD`rte ' '
` +RECEIPT; #
`CHECK'#;
CLTD BY
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00
_ 'DESCRIPTION -' ;,
4
ACCOUNT r
QTY
` AMOUNT•:=`
'< _�.�PAID``'" -
PAID DATE`
EXHAUST HOOD
101-0000-42402
0
$12.09
$0.00
F_`'.PAID,FBY M+' `<, ,'
METHOD : +
rX
RECEIPT #` '`
CHECK#
CLTD;BY
COUNTS' .
CfTY
}K AMOUNT
n,r; PAID
! PAID•DATE
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$0.00
r`i 7 PAIDZY,.=`
METHOD f
RECEIPT#gym..
ECK#�
"CLTD BY,
Total Paid for MECHANICAL: $16.92 $0.00
u.Y DESCRIPT.ION ti + `
�« .'ACCOUNT '"+QTY
a y IAMOUNT
PAID ''
PAID«DATE
FIXTURE/TRAP
101-0000-42401
0
$36.27
$0.00
, METHOD a
- .k'# RECEIPT,# xt '
.r .CHECK #
CLTD BY;.
DESCRIPTION` L,'*ACCOUNT�r
`` + t
#-QTY
' "s .AMOUNT
Al
PAID:DATE
FIXTURE/TRAP PC
101-0000-42600
0
$36.27
$0.00
? , '+PAID BY'-"':"METHOD'.','!
3�'tZRECEIPT4f
^ +;CHECK#
CLTD BY,,
` DESCRTTION=} +
ACCOUNT<f ' J ;{
`'QTY `Wit'
`AMOUNT ="'
P' ` rPAID�
;PAID DATE;
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$12.09
$0.00
�• ',t=; `PAID, BY , µ .' t x xr
; _� `G METHODI'C
LTD BY
i
• `` ;DESCRIPTION ' ;•
°AC_COUNT
4Q
' ` 'AMOUNT, "'4�
PAID t+'
PAID DATE
y ._ .
,
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$24.17
$0.00
METHOD'
RECEIPT~# q
a "µCHECK#
;CLTD BY;"
fy. a A"`
4 „ ,
s; k
Total Paid for PLUMBING FEES: $108.80 $0.00
"ACCOUNT r
QTY
x' AMOUNT
PAID'""
-PAID DATE
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400.
0
$43.50
$0.00
`PAID BY "; :.:
"' METHOD'
RECEIPT:#
"CHECK #,
CLTDBY_'
` r.,."DESCRIPTION ',;`t' ;"
::_` . i ',ACCOUNT„ �'''�a
QTY:
le =AMOUNT t
� :PAID
;PAID DATE
,.
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$34.80
$0.00
''PAID:BY' e° `' ;
- '`7 4 ' .c1L 1�
` w� <+S RECEIPT..# t
� +' : CHECK#
CLTD BY
? .METHOD ,
.....
DESCRIPTION f tt ::
" �' 'x , E ;ACCOUNT ,=F - ; .r
i"*QTYa
17
: � AMOUNT"
,:,PAID
PAID DATE
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
BY
i.METHODx '
RECEIPT#�^ ;
CHECK #-
CLTDBY.•
DESCRIPTION wr '3, '' T
�`' r :ACCOUNTS 'tFt s,
`QTY
AMOUNT
= , PAID,,' -
PAID DATE{
,
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$134.88
$0.00
7.
.PAID BYE, 3,.°� r'...
'METHOD �� : r
RECEIP,T # . k;�
. CHECK #•. '.
CLTD."BY •,
x
S;s X
Total Paid for REMODEL: $262.49 $0.00
DESCRIPTION ;
; " ACCOUNT ,M
QTY
'r�'AMOUNT
,PAID
'PAID DATE'
SMI - RESIDENTIAL
101-0000-20308
0
$4.55
$0.00
.i`,',PAID.BY :'°
MF`'�, METHOD" r
a`RECEIPTa#
CHECK#
r CLTD BY
z
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $4.55 $0.00
r.^ "DESCRIPTION "t
h " ,,,.,ACCOUNT', ,"`
,"QTY"
.x r'AMOUNT `''
PAID''
PAID DATE"
DOOR/WINDOW, REPLACE FIRST 7
101-0000-42400
0
$60.91
$0.00
- PAID BY
METHOD i
RECEIPT # 3
CHECK #
CLTD BY
a.' DESCRIPTION', =
,A000UNT
". Q N
AMOUNT
.,� a^
PAID
PAID "DATE'
ry
}t
t e
r A yy r„
DOOR/WINDOW, REPLACE, FIRST 7 PC
101-0000-42600
0
$110.22
$0.00
PAID''
METHOD �`��?`''
`"nytRECEIPT;#
r �CHECK�#i� _
CLTD BYE.
Total Paid forWINDOW/SLIDING GLASS DOOR/FENESTRATION: $171.13 $0.00
TOTALS:00
Description: REMODEL KITCHEN, WINDOWS AND DOORS
r.
. �
Type: BUILDING, RESIDENTIAL
Subtype: REMODEL
Status: APPROVED
ADDITIONAL SITES
Applied: 10/20/2014 SKH
Approved:
Parcel No: 643120050 Site Address: 47645 VIA MONTANA LA QUINTACA 92253,
Subdivision: TR 261S2
Block:
Lot: 278
CHRONOLOGY
issued:'
Lot Scl Ft: 0
Building Sq Ft: 0
Zoning:
Finaled:
Valuation: $35,000.00
Occupancy Type:
Construction Type:
Expired:
FROM CONSULTANT
Details: FULL KITCHEN REMODEL WITH BUTLER'S PANTRY. NEW SLIDING DOORS AND WINDOWS.
11/5/2014
. . -
Printed: Thursday, December 1lZOz44kZzlNPN' 1cf4
—____-- ----
'
`
r.
. �
^ `
.
^
. . -
Printed: Thursday, December 1lZOz44kZzlNPN' 1cf4
—____-- ----
'
`
ADDITIONAL SITES
CHRONOLOGY
YTYPE
PLAN CHECK COMMENTS
FROM CONSULTANT
KAY HENSEL
11/5/2014
11/5/2014
STRUC APPROVABLE 11/5
RECEIVED
PLAN CHECK COMMENTS
FROM CONSULTANT
PHILIP JUAREZ
12/15/2014
PLANS RECIEVED FROM YOUNG APPROVED.
RECEIVED
PLAN CHECK PICKED UP
STEPHANIE KHATAMI
11/6/2014
11/6/2014
PICKED UP BY ANDRES WEBER (SK)
PLAN CHECK SUBMITTAL
KAY HENSEL
10/20/2014
RECEIVED
PLAN CHECK SUBMITTAL
.
STEPHANIE KHATAMI
1 2/1/20.14
12/1/2014
RECEIVED
SENT TO PLAN CHECK
KAY HENSEL
10/20/2014
10/20/2014
STRUC TO YOUNG, DUE 11/3/14
CONSULTANT
. . -
Printed: Thursday, December 1lZOz44kZzlNPN' 1cf4
—____-- ----
'
`
TELEPHONE CALL
ARMEN ALTOUNIAN
11/6/2014
11/6/2014
CALLED ANDRZEJ WEBER AND HE WI LL PICK UP THE PLANS.
TELEPHONE CALL
ARMEN ALTOUNIAN
12/16/2014
12/16/2014
PLANS APPROVED AND READY FOR PICK UP.
CONDITIONS
YES
CONTACTS
Total Paid forBLDG CITY STAFF - PER HOUR. $175.00 $0.00
BSAS SB1473 FEE
101-0000-20306
$2.00
STATEf—
APPLICANT
ANDRZEJ WEBER
2276 VIA ALBA
PALM DESERT CA.
92260
(760)340-3002
RESIDENTIAL, FIRST
101-0000-42403
CONTRACTOR
MIKE HART
42935 VIRGINIA AVE
PALM DESERT CA
(760)340-3002
OWNER
FRANK RASADA
1115 MADISON ST NE #
816
SALEM OR
92253
(760)346-3002'
FINANCIAL INFORMATION
IL
HOURLY PLAN CHECK -
101-0000-42600 2.5 $175.00 $0.00
YES
Total Paid forBLDG CITY STAFF - PER HOUR. $175.00 $0.00
BSAS SB1473 FEE
101-0000-20306
$2.00
Total Paid forBUILDING STANDARDS ADMINISTRATION
RESIDENTIAL, FIRST
101-0000-42403
0
$14S.03
$0.00
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$0.00
1,OOOSF, PC
Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00
EXHAUST HOOD
101-0000-42402
0
$12.09
$0.00
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$0 00
Total Paid forMECHANICAL: $16.92 $0.00
FIXTURE/TRAP
101-0000-42401
0
$36.27
$0.00
'
Printed: Thursday, December 18,20144:21:08PN Zcf4 '
' CRW.~'~..
` ' ~
,OF
Printed: Thursday, December 18, 2014 4:21:08 PM 3of4 CRSYSTEMS
7- 7-7
LT6,
DESCRIPTION
UNi�',�'
AMOUNT
PA D
PAID DATE,
RECEIPT#'
.'nCHECK.#
METHOD,
PAID
FIXTURE/TRAP PC
101-0000-42600
0
$36.27
$0.00
GAS SYSTEM, 1-4
101-0000-42401
0
$12.09
$0.,00
OUTLETS
GAS SYSTEM, 1-4.
101-0000-426000
$24.17
$0.00
OUTLETS PC
Total Paid for PLUMBING FEES: $108.80 $0.00
REMODEL, EA
101-0000-42400
0
$43.50.
$0.00
ADDITIONAL 500 SF
REMODEL, EA
101-0000-42600
0
$34.80
$0.00
ADDITIONAL 500 SF PC
REMODEL, FIRST 100 SF1
101-0000-42400
0,
$49.31
$0.00
REMODEL, FIRST 500 SF
101-0000-42600
0
$134.88
$0.00
PC
Total Paid for REMODEL: $262.49 $0.00
SMI - RESIDENTIAL
101-0000-20308
0
$4.55
$0.00
Total Paid forSTRONG MOTION INSTRUMENTATION SM!$4.55 $0.00
DOOR/WINDOW,
101-0000-42400
0
$60.91
$0.00
REPLACE FIRST 7
DOOR/WINDOW,
101-0000-42600
0
$110.22
$0.00
REPLACE, FIRST 7 PC
ti
'Total Paid forWINDOW/SLIDING GLASS $171.13 $0.00
DOOR/FENESTRATION:
TOTALS: $933.78 $0.00
Printed: Thursday, December 18, 2014 4:21:08 PM 3of4 CRSYSTEMS
Printed: Thursday, December 18, 2014 4:21:08 PM
4of4
yPATHNAME, T£ SUBOIR rETRAKIT,ENABLED.;
PARENT
PROJECTS
0
REVIEWS
%Av;REVIEW TYPE= a
.:: "9•: wii - -
,,-- -__
REVIEWER
• s=.
.� �.�,`?r"'
-SENT-DATE
-- �_«isr
,� .,_
-DUE DATE "
,RETURNEDti`
; �; _ �.:
�, z
DATE �?��
STATUS
se :,c. S d,;-
x.• .
�„w�_�..�z�.:..,.:�." �
. a rrc: 'i*r s�
C,3r, .-+ *�
�.�.-..,...> •:
cr .«r:+�`-�3 •kt';NOTES...,:
;":fi �1" ..'..' tt•7+^ a.o i"!:
x ; `�. .��,; -T: ° s;_ •tea � •�:�.•�
NON-STRUCTURAL
ARMEN
ALTOUNIAN
10/20/2014
11/3/2014
10/21/2014
REVISIONS REQUIRED
1ST PLAN CHECK RFC
READY FOR CORRECTIONS
STRUCTURAL
JOHN
THOMPSON
10/20/2014
11/3/2014
APPROVED -
k-
STRUC APPROVED
11/5
STRUCTURAL
BRONZ
YOUNG
12/1/2014
12/14/2014
12/16/2014,
APPROVED.
2ND PLAN CHECK.
APPROVED
NON-STRUCTURAL
ARMEN
ALTOUNIAN
12/1/2014.
12/14/2014
12/1/2014
`- APPROVED
2ND PLAN CHECK
APPROVED
Printed: Thursday, December 18, 2014 4:21:08 PM
4of4
• COTW.,YSTEMS
yPATHNAME, T£ SUBOIR rETRAKIT,ENABLED.;
47-645 VIA
MONTANA.docx
0
• COTW.,YSTEMS
Bin # ..o
City of La Quinta
Building 8F Safety Division
P.O. Box 1504, 78-495 Calle Tampico.
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
� � Zjc>44t_A
Project Address: "76A
l�°•�l 7 WA A m osl*N
Owner's Name: zr-f �' /��'�(� t2,10 M
A. P. Number: —' ^ �So
Address: a
Legal Description: 'C, OT' 2� 6 Z e
T6
City, ST, Zip:
ntract
Co r• o . I
Tc h nc:
p
Address:
Project Description: rr G`4.�`� r���✓\
City, ST, Zip:
p
�� �. J (/J V .v p•� IOW
Telephone:
J ( � Q- D 1.0"
State Lie. #:
City Lie. #.
—
Arch., Engr., Designer:
Address: Z� (��^ ��� MAS
City, ST, Zip: p �' l
Telephone: k 3t-0, 3 On 2
;:;t::;;::.;;:;:.:
Construction Type: Occupancy: 3
V
/
State Lie- #: C i2 �j
>?
� :•.'^Q:! iii ��+.::i �?:v:.::? i:Y•iF•:::•:
...... .
Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person:
Sq. Ft.: �—'
# Stories: 1
#Units: l
Telephone #,of Contact Person: Fye �,� 00'z_
Estimated Value of Project.
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
3
Plan Check submitted
�Q
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
t 6
Plan Cluck Deposit
Truss Cala.
Called Contact Person!
I/
Plan Check Balance.
Title 24 Calcs.
Plans picked up ANtile, .
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for correction /issue .
`2J1r
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Decd
Plans picked up
S.M.I.
Ii.O.A. Approval
Plans resubmitted
Grading
IN IiOUSE:-
'`d Review, ready for corrcctionstissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees 0
T 2 0 2.014
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
To:
Attn:
84744S VIA M -4w &,oYTANp
Pi s X14- 118
77-682 Country Club Dr. Ste.. B, Palm Desert, CA 92211 ph. (760)'772-5107 fax (760) 345-7620
Letter of Transmittal
City of La Quinta Today's Date: 11`-4-14
78-495 Calle Tampico City Due Date: 11-3-14
La Quinta, CA 92253 Project Address: 47-645 Via Montana
Kay Plan Check #: BRES 2014-1138
Submittal: ® 1st ❑ 4th
We are forwarding:
Includes:
# Of
Copies:
1
A
® By Messenger
4
Descriptions:
Structural Plans
❑ 2nd ❑ -55th
❑ V ❑ Other:
❑ By Mail (Fed Ex or UPS) ❑ Your Pickup
Includes: # Of Descriptions:
Copies:
Structural Calculations
Truss Calculations Floor
.and Roof
Soils Report
Structural Comment List
Redlined Structural Plans
Redlined Structural Calcs
Redlined Truss Calcs
Redlined Soils Reports
❑
Revised Structural Plans
❑
Revised Struct. Calcs
❑
Revised Truss
❑
Revised Soils Report
❑
Approved Structural Plans
❑
Approved Structural Calcs
❑
Approved Truss Calcs
❑
Approved Soils Report
❑
Other:
Comments: Structural content is approvable. �\
I L � lie V L
By: Kathryn Samuels
Palm Desert Office: ® (760) 772-5107
Other: ❑
If you have any questions,
please call.
NOVU
Time = 1.5 HR
iii vi b= QU
This Material Sent for:
COMMUNITYDEVELC.
❑
Your Files
®
Per Your Request
❑
Your Review
❑
Approval
❑
Checking
❑
At the request of:
Other: ❑
By: Kathryn Samuels
Palm Desert Office: ® (760) 772-5107
Other: ❑
The Management Trust
MONARCH GROUP DIVISION
September 22, 2014
FRANK & MARY RASADA
47645 VIA MONTANA
LA QUINTA, CA 92253
RE: Architectural Submittal for 47645 VIA MONTANA 278
Account #659797
Dear Homeowner.
The Architectural Review Committee for LAKE LA QUINTA has reviewed and APPROVED your architectural submittal for
the installation of replacing the rear sliding doors, add installation of a new window for the kitchen, and remove the center
post in rear patio per the plans submitted.
ARC approval of plans shall not constitute a representation, warranty, or guarantee that such plans and specifications
comply with engineering design practices or zoning and building ordinances, or other governmental agency regulations or
restrictions. The ARC shall not be responsible for reviewing, nor shall its approval of any plans or design, be deemed
approved from the standpoint of structural safety or conformance with building or other codes. By approving such plans
and specifications, neither the ARC, the Members thereof, the Association, any Member thereof, their Board of Directors,
any Members thereof, or the Declarant assumes any liability or responsibility therefore or for any defect in the
construction or improvement from such plans or specifications. As provided in the. CC&R's neither the ARC, the
Association, the Board of Directors or the Association or any Members thereof, not the Declarant or Developer shall be
liable to any Member, Owner, Occupant, or other person or entity for any damage, loss or prejudice suffered or claimed
on account of (1) the approval or disapproval of any plans, drawings, or specifications, whether or not'defective, or (2) the
construction or performance of any work whether or not pursuant to the approved plans, drawings, or specifications.
Your patience and cooperation with the architectural review process is appreciated. If you have any questions, please
contact the association at (760) 776-5100, Extension 333. .
c
Sincerely,
On behalf of the LAKE lA QUINTA Architectural Review Committee
Wendy Coyne
The Management Trust - Monarch Group Division
Enclosures (1)
cc: Board of Directors
Unit File
39755 Berkey Drive, Suite A, Palm Desert, CA 92211
AN EMPLOYEE OWNED CONIPAM' PH: 760.776.5100 FAX: 760.776.5111
www.managementtrust.com
ear
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Mr. & Mrs. Frank:& Mary Rasada Residential Remodel
47 645 Via Montana, Lake La Quinta
La Quinta, CA 92253.
Project Designer:
Andrzej W. Weber Architect
2276 Via Alba
Palm Desert, CA 92260
760.340.3002 -
Report Prepared by:
Wayne Seward
Bear Technologys
7774, Calle Mejor
Carlsbad, CA 92009
760.635.2327
' r
INTA
CITY OF LAQU DEPT.. Job Number: D Q
BUILDING & SA
FETYAppFiOVE® 14Q4020.3-2. DEC 0 2014
FOR CONSTR ION
- Cl OF LA QUINTA
Date:, COMMUNITY DEVELOPMENT DEPARTMENT
DATE�BY
11/11/2014
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
Ener Pro 6.3 by Ener Soft User Number: 5956 ID: 14Q4020.3-2
'TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 11
Form MF -1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 15
EnergyPro 6.3 by EnergySoft Job Number: ID: 14Q4020.3-2 User Number: 5956
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014 .
Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml
CF1 R -PRF -01
Page 1 of 8
GENERAL INFORMATION
01
Project Name Mr. & Mrs. Frank & Mary Rasada Residential Remodel
02
Calculation Description Title 24 Analysis
03 This building incorporates one or more Special Features shown below
03
Project Location 47 645 Via Montana, Lake La Quinta
04
CA City La Quinta
05
Standards Version
Compliance 2014
06
Zip code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3 (651)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.3
10
Building Type Single Family
11
Front Orientation (deg/Cardinal)
90
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2) 3013
15
Number of Zones
1
16
Slab Area (FT2) 3013
17
Number of Stories
1
18
Addition Cond. Floor Area 0
19
Natural Gas Available
Yes
20
Addition Slab Area (FT2) 0
21
Glazing Percentage (%)
15.2%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04 05
06
07
08
Energy Use (kTDV/ft2-yr) Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating 2.33
2.07
0.26
11.2%
Space Cooling 134.84
124.37
10.47
7.8%
IAQ Ventilation 0.00
0.00
0.00
0.0%
Water Heating 9.00
9.00
0..10+
l-'0
Photovoltaic Offset —
0.00
AV f
TOTAL 146.17
135.44
1 , ' / I L_N
i` � 1 �;3$/;
/Ar hu V t
FOR CONSTRUCTION
DATE BY
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-1118:10:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014 Page 2 of 8
Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
Cool roof
Cathedral Ceiling
PROJECT HERS FEATURES
The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed
in the building components tables below, requre field verification by a certified HERS Rater.
Building -level Verifications:
— None —
Cooling System Verifications:
— None —
HVAC Distribution System Verifications:
— None —
Domestic Hot Water System Verifications:
— None = _
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2)• 183.68 172.95 10.73 5.8%
` includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING FEATURE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
Number of Dwelling
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Number of
Number of Water
Project Name
Conditioned Floor Area (sft)
Units
Number of Bedrooms
Number of Zones
Ventilation Cooling Systems
Heating Systems
Mr. & Mrs. Frank & Mary Rasada
3013
1
4
1
0
1
Residential Remodel
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing Residence
Conditioned
Res HVAC1
3013
10.2
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-1118:10:48
N
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. 8 Mrs. Frank 8 Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml
CF1 R -PRF -01
Page 3 of 8
_x
OPAQUE SURFACES
01
02
03
04
05
06
07 08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (f:2)
Window and Door Tilt(deg
Area (ft) )
Status
Verified
Existing
Condition
North Wall
Existing Residence
R-19 Wall
0
Right,
856.8
56 90"
Existing
No "
East Wall
Existing Residence
R-19 Wall
.90
Front
320.8
46.5 90
Existing
No
South Wall
Existing Residence
R-19 Wall
180
Left
856.8
77.8 90
Existing
No
West Wall
Existing Residence
R-19 Wall
270
Back
632.4
278 90
Existing
No
Roof 2
Existing Residence
R-30 Roof Attic
Existing Residence
R-30 Roof
3013
198
Existing
No
(e) GarageWall North
Garage
Garage Ext Wall
0
Right
184.5
90
Existing
No
(e) GarageWall East
Garage
Garage Ext Wall
90
Front
279
174' 90
Existing
No
(e) GarageWall South
Garage
Garage Ext Wall
180
Left
184.5
90
Existing
'No
IS
Garage>>Existing Residence
R-13 Wall
0.1
I
0.85
315
fi -,
Existing
No
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
06
07-
08
09
10
11
12
13
Radiant
Barrier
Cool Roof
Status
Verified
Existing
Condifion .
Attic
Attic Roof Cons
4
0.3
0.75
Roof
Roof
Framin
No
Verified
Orientatio
Area
Skylight
Roof Rise
Roof
Roof
Reflectan `
Emmittan
g
Statu
Existing
Name
Zone
Type
n
(ft)
Area (ft2)
(x in 12)
Pitch
Tilt(deg)
ce
ce
Factor
s
Condifion
Roof
Existing Residence
R-30 Roof
- specify -
198
0
4
0.33
18.43
0.1
0.85
0.1
Existin"
No
Cathedral
9
(e)GarageRoof
Garage
R-30 Roof
-specify-
0
4
0.33
18.43•
0.1
I
0.85
0.1
Existin
.
No
Cathedral
,608
g
ATTIC
01
02
03
04
05
06
09
10
11
Name
Construction
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool Roof
Status
Verified
Existing
Condifion .
Attic
Attic Roof Cons
4
0.3
0.75
Yes
Yes
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651' Report Generated at 2014-11-1118:10:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml
CF1 R -PRF -01
Page 4 of 8
WINDOWS
01
02
03
01
02
03 04 05
06
07
08
09
10
11
Name
Side of Building
Width(ft Height Multiplie
) (ft) r
Area (W)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
(e) IAL 1
North Wall
- - 1
25.0
0.32
0.25
Insect Screen (default)
Existing
No
(e)W-2
North Wall
- - 1
6.0
0.32
0.25
Insect Screen (default)
Existing
No
(e)W-3
North Wall
- - 1
25.0
0.32
0.25
Insect Screen (default)
Existing
No
(e)W-4
East Wall
- - 1
19.0
0.32
0.25
Insect Screen (default)
Existing
No
(e)W-6
East Wall
- - 1
27.5
0.32
0.25
Insect Screen (default)
Existing
No
(e)W-5
South Wall
- - 1
19.0
0.32
0.25
Insect Screen (default)
Existing
No
(e)W-7
South Wall
- - 1
3.0
0.32
0.25
Insect Screen (default)
Existing
No
(e)W-8
South Wall
- - 1
3.0
0.32
0.25
Insect Screen (default)
Existing
No
(e)W-9
South Wall
- - 1
3.0
0.32
0.25
Insect Screen (default)
Existing
No
(e)W-10
South Wall
- - 1
25.0
0.32
0.25
Insect Screen (default)
Existing
No
56X46 FIXED GLASS WINDOW
South Wall
- - 1
24.8
0.32
0.25
Insect Screen (default)
New
N/A
120X80 SLIDING DOOR
West Wall
- - 1
96.0
0.32
0.25
Insect Screen (default)
Altered
N/A
80X80 SLIDING DOOR
West Wall
- - 1
64.0
0.32
0.25
Insect Screen (default)
Altered
N/A
80X80 SLIDING DOOR 2
West Wall
- - 1
64.0
0.32
0.25
Insect Screen (default) I
Altered
N/A
120X46 FIXED GLASS WINDOW
West Wall
- - 1
54.0 1
0.30
0.22
Insect Screen (default)
Altered
N/A
DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft)
U -factor
Status
Verified Existing Condition
(e)D-2
North Wall
48.0
0.50
Existing
No
(e)D-1
East Wall
50.0
0.50
Existing
No
NEW SIDE ENTRY DOOR 30X80
South Wall
24.0
0.50
Altered
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at 2014-11-1118:10:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Daterrime: 18:09, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml
CF1 R -PRF -01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
Construction Name
Surface Type
Framing
Total Cavity R -value
Assembly Layers
Zone
Area (ft)
2x4 Top Chord of Roof
Edge Insul. R -value
Cavity/ Frame: no insul. /2x4 Top Chrd
Attic Roof Cons
Attic Roofs
Truss @ 24 in. O.C.
- no insulation -
Roof Deck: Wood Siding/sheathing/decking
3013
261
- none -
0.8
• Roofing: Light Roof (Asphalt Shingle)
Existing
No
• Inside Finish: Gypsum Board
R-30 Roof Cathedral
Cathedral Ceilings
2x12 @ 16 in. O.C.
R 30
Cavity/Frame: R -30/2x12
• Roof Deck: Wood Siding/sheathing/decking
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
R-13 Wall
Interior Walls
2x4 @ 16 in. O.C.
R 13
Cavity/Frame: R -13/2x4
• Other Side Finish: Gypsum Board
• Inside Finish: Gypsum Board
R-30 Roof Attic
Ceilings (below attic)
2x4 @ 24 in. O.C.
R 30
Cavity/Frame: R-9.1 /2x4
• Over Floor Joists: R-20.9 insul.
• Inside Finish: Gypsum Board
R-19 Wall
Exterior Walls
2x6 @ 16 in. O.C.
R 19
Cavity/ Frame: R -19/2x6
• Exterior Finish: Wood Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
08
09
' Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
Existing Residence
3013
261
- none -
0.8
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required Not Required —
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
Distribution Type
Number of Heaters
Solar Fraction (%)
Status
Verified Existing
Condition
DHW Sys 1
Standard
1
Annual
Existing
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at 2014-11-1118:10:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml
CF1 R -PRF -01
Page 6 of 8
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.575 EF
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05"
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
HVAC SYSTEMS
01
02
01
02
03
04
05
06
07
08"
09
Name
Heating System
Cooling System
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
11.3
13
No
No
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Res HVAC1
Other Heating and
Heating.
Yes
Cooling
Yes
Air Distribution
HVAC Fan
3013
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Efficiency. .
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
11.3
13
No
No
N/A
system
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-1118:10:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Date/Time: 18:09, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml
CF1R-PRF-01
Page 7 of 8
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
08
Insulation
Supply Duct
Return Duct
Verify Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
N/A
System 1
specified)
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-1118:10:48
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Frank & Mary Rasada Residential Remodel Calculation Datefrime: 18:09, Tue, Nov 11, 2014
Calculation Description: Title 24 Analysis Input File Name: 14Q4020.3-2.xml
CF1 R -PRF -01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION. STATEMENT
1. 1,certify that this Certificate of Compliance documentation is accurate and complete:
Documentation Author Name: Documentation Author Signature:�� cJ
Wayne Seward
Company:
Signature Date:
Bear Technologys
11/11/2014 LABEC
carom, A. -WI -4 amd,g EMM
CEA/HERS Certification Identification (If applicable): MEMM
_
Address:
7774 Calle Mejor
City/stateEa�lsbad, CA 92009
Phone: 760.635.2327
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance:
2.. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part -6 of the.California Code of
Regulations. .
Compliance the information r documents,
3. The building design features or system design features identified on this Certificate of are consistent with pro/ided on applicable compliance
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application/
Responsible Designer Name:
Responsible Designer Signature:
Andrzej W. Weber r
Company:
Date Signed:
Andrzej W. Weber Architect
?"0.
Address:
License:
2276 Via Alba
City/State/Zip:
Phone:
Palm Desert, CA 92260
760.340.3002
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-6S1
HERS Provider:
Report Generated at 2014-11-1118:10:48
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Mr. & Mrs. Frank & Mary Rasada Resident
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration 11111112014
Date
Project Address
47 645 Via Montana, Lake La Quinta La
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,013
Addition
0
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Roof Wood Framed Rafter R 30 198 Existing
Roof Wood Framed Attic R 30 3,013 Cool Roof Existing
Wall Wood Framed R 19 2,087 Existing
Door Opaque Door no insulation 98 Existing
Door Opaque Door no insulation 24 Altered
Slab Unheated Slab -on -Grade no insulation 3,013 Perim = 261' Existing
FENESTRATION Total Area: 458 Glazing Percentage: 15.2%1 New/Altered Average U -Factor: 0.32
Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status
Right (N) 56.0 0.320
0.25 none none Bug Screen Existing
Front (E) 46.5 0.320
0.25 none none Bug Screen Existing
Left (S) 53.0 0.320
0.25 none none Bug Screen Existing
Left (S) 24.8 0.320
0.25 none none Bug Screen New
Rear (W) 224.0 0.320
0.25 none none Bug Screen Altered
Rear (lM 54.0 0.300
0.22 none none Bug Screen Altered
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
2 Central Furnace 80% AFUE
Split Air Conditioner 13.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Res HVAC Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 6.3 by Ener Soft User Number: 5956
RunCode: 2014-11-11718:12:36 ID: 14Q4020.3-2
Pae 11 of 15
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MFA R
Project Name
Date
Mr. & Mrs. Frank & Mary Rasada Residential Remodel
11111112014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form.
§110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50.0 a : Minimum R-30 R-19 for Alterations insulation in wood -frame ceiling orequivalent U -factor.
§150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor.
*§150.0(d): Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor.
150.0 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
§150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the
requirements of either Item 1 or 2 below:
1. Fenestration, including skylight products, must have a maximum U -factor of 0.58.
2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58.
EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is
reater, is exempt from the maximum U -factor requirement.
150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
eq ui ed with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5.
§110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
§150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA.
§150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c .
§150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally
wrapped with insulation having an installed thermal resistance of R-12 or greater.
§150.0(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
EnergyPro 6.3 by EnergySoft User Number: 5956 ID: 14Q4020.3-2 Page 12 of 15
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Mr. & Mrs. Frank & Mary Rasada Residential Remodel
11111112014
§150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE
120.3-A.
i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank.
ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger.
iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter.
iv. Piping from the heating source to storage tank or between tanks.
v. Piping buried below grade.
vi. All hot water pipes from the heating source to the kitchen fixtures.
§150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards
Table 120.3-A.
150.00)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
§150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC
Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed
level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that
meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic
or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
§150.0(m)7: Exhaust fans stems have back draft or automatic dampers.
§150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150.0 m 10: Flexible ducts cannot have porous inner cores.
§150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include
all the following components :
A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions;
B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water
heater is installed;
C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining
without pump assist,
D. A qas supply line with a capacity of at least 200,000 Btu/hr.
§150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality
in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
ro rammed to run only during off-peak electric demand periods.
§150.0(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150.0
Residential Lighting Measures:
§150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance
with TABLE 150.0-A or TABLE 150.0-B, as applicable.
150.0 k 1C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c).
150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz.
§150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume
no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not
be required to be controlled by vacancy sensors.
EnergyPro 6.3 by EnergySoft User Number: 5956 ID: 14Q4020.3-2 Page 13 of 15
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MFA R
Project Name
Date
Mr. & Mrs. Frank & Mary Rasada Residential Remodel
11111112014
150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens shall meet the applicable requirements of §150.0(k).
§150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2.
§150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f12 or 100 watts
for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all
lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also
controlled by vacancy sensors or dimmers.
§150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
§150.0(k)5: Lighting installed in bathrooms shall meet the following requirements:
A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and
B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be
high efficacy, or shall be controlled by either dimmers or vacancy sensors.
EXCEPTION 1: Luminaires in closets less than 70 square feet.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site.
§150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air
leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on
the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items
ii or iii below; and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and
automatically reactivates the motion sensor within 6 hours
iii. Controlled by one of the following methods:
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and
which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements:
At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9;
meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in
Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
§150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and
outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
following requirements:
i. Shall comply with Section 150.0(k)9A; or
ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or
Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall
comply with the applicable requirements in Sections 110.9 130.0, 130.2, 130.4, 140.7 and 141.0.
§150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume
no more than five watts of power as determined according to §130.0(d).
§150.0(k)11: Lighting for residential parking garages for eight or more
vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1,
130.4, 140.6, and 141.0.
§150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent
or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
§150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than
20 percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
EnergyPro 6.3 by EnergySoft User Number: 5956 ID: 14Q4020.3-2 Page 14 of 15
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Mr. & Mrs. Frank & Mary Rasada Residential Remodel
Date
11/11/2014
System Name
Res HVAC
Floor Area
3,013
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 1,793
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem
24,000
35,589
3,656 680
33,265
Total Output Btuh
48,000
0
Output Btuh/s ft
15.9
3,018
2,363
Cooling System
0
0
Output perSystem
24,000
0
0 0
0
Total Output Btuh
48,000
0
3,656
0
Total Output Tons
4.0
3,018
2,363
Total Output Btuh/s ft
15.9
Total Output s ft/Ton
753.3
41,624
37,991
Air System
CFM perSystem
1,050
HVAC EQUIPMENT SELECTION
Airflow cfm
2,100
Standard Existing HVAC System 34,039 6,881
48,000
Airflow cfm/s ft
0.70
Airflow cfm/Ton
525.0
Total Adjusted System Output 34,039 6,881 48,000
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Outside Air % 0.0%
Outside Air cfm/s ft 0,00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 67 IF
Outside Air
0 cfm Supply Fan
2,100 cfm
67 OF
67 OF 115 OF
Heating Coil 114 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 / 78 OF 76162
Outside Air Ar
0 cfm
76162 OF
OF 76 / 62 OF 55 / 54 OF
Supply Fan Cooling Coil 56 ! 54 OF
2,100 cfm .... .... ....._...._... ..
C��TY OF LA Q�,��NTA OOM mIq
_ 31JI rDING & SAFETY DEP 75 / 62 OF
A D 0
1. FOR CONSTRUCTION
EnergyPro 6.3 by EnergySoft
User Number: 5956 RunCode: 2014-11-11718:12:36 ;;,2: 14Q4020.3-2
Page 15 7 15