Loading...
07-0657 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA,•CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number:07-OA0006 - Property Address: 4-"73-0 VIA MONTANA APN: 643-120-036-2.64 -2'6152 - Application description: ADDITION- RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 28361 Applicant: Architect or Engineer: Owner: ARNE & PATRICIA ADAMS 44730 VIA MONTAN LA QUINTA, CA 92j Contractor: FRENCH CONSTRUCTI 705 SUNNYSIDE AVE REDLANDS, CA' 9237 (909)841-1379 Lic. No.: 667383 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 tl� 61 L00_I -""".�..._Qli1WCA N(U0� o ._" e,,szPT- Date: 3/27/07 Date: Owner: •• CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). - Lender's Name: Lender's Address: of La Qwnta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.. 2. Any permit issued as a result of this application becomes null arid void if work is not commenced within 180 days from date -of issuance of such permit, or cessation of work. for 180 days will subject permitto cancellation. _ I certify that I have read this application and state that the above information is correct. 1 agree o comply with all city and county ordinances and state laws relating to building construction, and hereby orize re esentatives of this county to enter upon the above-mentioned property nspection purposes. LQPERMIT _ ` f LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9.(commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division'3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided ` License Class* 13 - Lie a o.: 667383 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Date: Z -0ritra&o - - - - - _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation WNER-BUILDER DECLARATION insurance carrier and policy number are: . I hereby affirm under penalty of perjury that I amexempt from the Contractor's State License Lawforthe Carrier EXEMPT Policy Number EXEMPT _ following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the wor ensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - -. and agree that, if I should become subject to the wo rs' compen tion provisions of Section .License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor Code, I shall forthwith comply ith those pro Bions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by zx any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: l Da(e�I/�����/� plica I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and --- *'y ` the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' C PENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors'. State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND - and who does the work, himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN • improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the _ -. 7044, Business and Professions Code:. The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed - 1. .Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). - - whose benefit work is performed under or pursuant to any permit issued as a result of this application, I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date: Owner: •• CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). - Lender's Name: Lender's Address: of La Qwnta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.. 2. Any permit issued as a result of this application becomes null arid void if work is not commenced within 180 days from date -of issuance of such permit, or cessation of work. for 180 days will subject permitto cancellation. _ I certify that I have read this application and state that the above information is correct. 1 agree o comply with all city and county ordinances and state laws relating to building construction, and hereby orize re esentatives of this county to enter upon the above-mentioned property nspection purposes. LQPERMIT _ ` f Application Number . . . . . 07-00000657 ------ Structure Information 351 SF ADDITION/V-NR/RES-3/CONVENTIONAL ----- Other struct info . . . . . CODE EDITION 2001/2005 # BEDROOMS. 1.00 FLOOD ZONE NO ----------------------------------------------------------------------------- 1ST FLOOR.SQUARE FOOTAGE 351.00 Permit . . . BUILDING PERMIT Additional desc . ' Permit Fee . . . . 278.00 Plan Check Fee .. 180.70 Issue Date . . . . Valuation . . . .. 28361 Expiration Date 9/23/07 Qty Unit Charge Per Extension BASE"FEE „ 252.00 4.00 6.5000 THOU BLDG 25,001-50,000 26.00 --------------------- ---------------- Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 27.29 Plan Check Fee 6.82 Issue Date Valuation 0 . Expiration Date 9/23/07 Qty Unit Charge Per Extension BASE FEE 15.00 '351.00 ".0350 ELEC NEW RES - 1 OR 2 FAMILY 12.29 ' Permit . . .. MECHANICAL Additional desc . Permit Fee 44.00 Plan Check Fee 11:00 u Issue Date Valuation . . . . 0 Expiration Date 9/23/07 Qty Unit Charge Per Extension BASE FEE' - 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 4.5000 EA MECH VENT'INST/ DUCT ALT 4.50 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA MECH VENT FAN - 6.50 Permit PLUMBING Additional desc . Permit Fee . . . . 49.50 Plan.Check Fee 12.38 Issue Date . . . . ..Valuation . . . . 0. LQPERMIT - - Application Number 07-00000657 Permit . . . . . . PLUMBING Expiration Date 9/23/07 ` Qty Unit Charge Per Extension . BASE FEE 15.00 3.00 6.0000 EA PLB FIXTURE 18.00 1.00 - 7.5000 EA PLB WATER HEATER/VENT 7.50 ' 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 2.00' 3.0000 EA PLB GAS PIPE 1-4.OUTLETS• 6.00 'Special Notes and Comments -- - - - - - - - - - - - - - - - - `. 351SF.CASITA ADDITION/V-NR/RES-3/ CONVENTIONAL. 2001 CBC, CMC, CPC, 2004 - ELEC, 2005 ENER. THIS PERMIT DOES NOT INCLUDE BLOCKWALLS. March 26, 2007 - 4:06:10 PM AORTEGA -' ' -------------------------- ------------------=------------------------------ Other Fees `. ENERGY. REVIEW FEE STRONG MOTION (SMI) - RES,_, 2.83 'Fee summary Charged Paid Credited ----------------- -------- Due -------- ------ Permit Permit Fee Total 398.79 .00: - ------ --- .00 398.79 Plan Check Total' `210.90. .00 .00 210.90 - ' 'Other -Fee Total 20.90• ' ,:-00 00 20.90 . • Grand Total 630.59.• _00 .00 630.59 LQMRAIIT .. - dIL, 3 0 • ,��+_ City Of U Quetta Permit #�/� ` Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 �/ Building Permit Application and Tracking Sheet Project Add : y �, �p U 6 /1'Jo vZiq,�� Owner'sName:AtzN A. P. Number: 21G14 s� Legal Description: Address: O i A AA . Contractor•.. �' �. N G l+ City, ST, Zip: CA Ff L Telephone: Address: p N_ G �U� project Description: City, ST, Zip: Telephone:' State Lic. #': % (p 7 3 �� . tatty Lic. # Arch., agr., Designer aO0. f Q 77 ip &O ov Address: Sl . a�2 A— City; ST, Zip: 17ALn�� 9 Z p Telephone7(OO, 2 �! State Lie. #: Construction Type: 9 F Occupancy: • Contact Person: prRiecttpe (circle New 'Add'n Alter Repair Demo �Sq F # stories:. Units- Telephone # of Contact Person: [j 77 Estimated Value orProject: APPLICANT: DO NOT VVRLTE BELOW THIS UNE # Submittal Req'd Recd TRACING Plan Sets 4�Z PERMIT FEES FURCheck submitted Item . Structural Calcs Reviewed, ready for corrections Amount Truss Glca. Called Contact person Plaa Chick Deposit . Energy Glp. Plan Check Balance Plans j►[cked.ap J Construction Flood plain plan I Plans resubmitted Grading. plan' Mechanical 21' Review, ready for corrections/issue Sabcontactor List'. Electrical Called Contact Person Grant Deed Plumbing Plans picked up • H.O.A. Approval SALL Plans resubmitted • IN ROUSE:= Grading '"' Review, ready for.correctio �ssae 3 {� Developer Impact Fee Planning Approval Called Contact Perso Pub. Wks. Appr A.LP.P.- Datt of permit issue School Fees Total Permit Fees -P7 rc„J U!T C/f-- CERTIFICATE OF COMPLIANCE Desert Sands Unified School District Zq�cS►T—iU1/�00 47950 Dune Palms Road ¢ BERMUDA DUNES r V] RANCHO MIRAGE Date 3/27/07 La Quinta, CA 92253 INDIAN WELLS PALM LA QUINTA V No. 29312 (760) 771-8515 Comments Attached Casita t At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for Irving, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies. that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 351 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Eric French Check No. Name on the check Telephone 909.841.1379 Funding Exempt By Dr. Doris Wilson f Superintendent Fee collected /exem,pte by haron cC31ly a Payment Recd "I go.0o 1; - ver/Uner> `,y. 4 Od Sim �%L 3 Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will sere to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building. Department/Applicant Copy- Applicant/Receipt Copy - Accounting O Owner Arne & Patricia Adams APN # 643-120-036 Address 47-730 Via Montana Jurisdiction La Quinta City La Quinta Zip 92.253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 47730 Via Montana 351 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Attached Casita t At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for Irving, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies. that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 351 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Eric French Check No. Name on the check Telephone 909.841.1379 Funding Exempt By Dr. Doris Wilson f Superintendent Fee collected /exem,pte by haron cC31ly a Payment Recd "I go.0o 1; - ver/Uner> `,y. 4 Od Sim �%L 3 Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will sere to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building. Department/Applicant Copy- Applicant/Receipt Copy - Accounting I _ • STH ,�a„ uric �i." March 8, 2007 Mr. Eric French French Construction, Inc. 82-388 Cochran Drive Indio, .CA 9220.1 SUBJECT: MINOR USE PERMIT 2007-901 CASITA:.47-730 VIA MONTANA Dear Mr. French: Your request for approval of Minor Use Permit -2007-901, allowing the construction of a casita/guesthouse at 47-730 Via Montana in. La Quinta, is hereby approved, subject to the following Condition: 1. The air conditioning condenser unit shall be moved to the area adjacent to the water heater and. the existing house,. as shown on the attached exhibit. You may now contact the Building & Safety Department for your building. permit. Enclosed is the approved original Deed Restriction for this Minor Use Permit. It must be signed by the. owner in' front of a Notary Public. The original approved - documents are . then to be recorded with the County Recorder, with a recorded copy given to the City for our files. The Community Development Department will sign the job card when the recorded copy. is received, which would provide our clearance to the Building & Safety Department to issue the building final inspection. Until the recorded copy is received by the Community Development Department; your Minor Use Permit is not complete and a final inspection will not be conducted by the Building & Safety Department. Should you have any questions, please call me at (760) 777-7125. T.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO • LA QUINTA, CALIFORNIA 92253 (760.),777-7000 -FAX (760) 777-7101 RECORDING REQUESTED BY:'- Mr: Y:Mr.: Arnie Adams WHEN RECORDED PLEASE MAIL TO: Mr. Eric French French Construction, Inc. 82-388 Cochran Drive Indio, CA 92201 COVENANT AND AGREEMENT RESTRICTING THE USE OF THE RESIDENCE AT 47-730 VIA MONTANA, LA QUINTA, CALIFORNIA This Covenant and Agreement are made and executed this 9th day of March by Quarry Ranch, 'LLC. -as the recorded owner(s) of the property. described herein. The City of La Quinta, a Municipal Corporation, is. hereby made a party to this Agreement for the purposes set forth below. The undersigned hereby. certifies, that he/she Is the property owner of the following described real property in the City of La Quinta, County of Riverside, State of California: LOT 264, TR 26152; APN: 643-120=036', in the City of La Quinta,, County -of Riverside, State .of California In consideration of the City of La Quinta issuing a building. permit for certain improvements which will.be constructed on said property, the.undersigned does hereby covenant and agree to, and with said City, to restrict the use of. said property as follows: 1. The guest house may not be rented nor sold independent ' of the main single- family residence (Minor Use Permit No. 2007-901.); 2. No kitchen or cooking facilities shall be constructed in the guest house per the provisions of Chapter 9.30.030 (RL Zone District) and 9.60.110 (Guest Houses) of the La Quinta Municipal Code; 3. All on-site facilities are intended for the sole occupancy of the property owner(s), guests, and caretakers (Le., a.maid and/or housekeeper, etc.); and, 4. The guest house shall be used primarily as a sleeping facility, and shall be maintained in accordance with all zoning and other codes as set forth in the La Quinta Municipal Code,, as' may be amended from time to time. r This Covenant and Agreement shall run with the land and shall be binding upon future owners, their successors, heirs, or assigns, . and ourselves,. and shall continue in effect while said accessory building remains on the real property. or unless otherwise released by the authority of the City of La Quinta. All leases of. said dwelling and/or property shall be subject to this restriction. This Agreement shall be entitled to the remedy of injunctive relief in addition of any remedy in law or equity. This Covenant and Agreement and the provisions hereof are irrevocable; except by the written consent of all parties to the agreement, including the City 'of La Quinta, a Municipal Corporation. The City shall have the right to enforce each and every provision hereof .and the parties agree that the. Agreement shall. not be rescinded, revoked, modified, or otherwise amended or changed, .without the expressed written consent of the City first being obtained. In the event that the owners,. their heirs, assigns or successors in interest, shall fail to perform any obligation hereunder, they hereby agree to pay all costs and. expenses incurred by. the City of La. Quinta in securing performance of such obligation, including attorney's fees. By: 1 2.. 3: Signature(s)'.Printed Name of all owners) 4Led: � a n Dateanager City of La Quinta ALL-PURPOSE NOTARY ACKNOWLEDGMENT(S) MUST BE ATTACHED IN 8.1/2 X 11" FORMAT, FOR EACH SIGNATURE: STATE OF CALIFORNIA) COUNTY OF RIVERSIDE_) ss. CITY OF LA QUINTA) On 3"8.0 7 befor me, Nota Public personally ry ,r Y appeared personally known to me or' proved to me on the basis of satisfactoryevidence to be .the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to .me that he/she/they executed the same in :his/her/their authorized capacity.(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my.hand and official seal, Signature of the Notary Public PAMELA S. NIETO Commisslon * 1723211 Notary Public • California Riverside County My Corn.1DVk9s feb 2, 2011 TITLE 24 REPORT Title 24 Report for: ARNE & PATRICIA ADAMS 47-730 VIA MONTANA LA QUINTA, CA 92.253 Project Designer: FERNANDO SILVA 45-175 PANORAMA DR. STE. A-1 PALM DESERT, CA 92260 760-799-2615 Report Prepared By: ADRIANA GIL Adriana Gil .74-854 Velie Way Ste. #8 Palm Desert, CA 92260 (760) 404-7917 7 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED Job Number: FOR CONSTR6CTION AbY392-0207 DA )26 PIA Date: 3/22/2007' The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number. ADY392-0207 User Number. 5553 1 2 3 7 9 User Number: 5553 . Certificate Of Compliance: Residential (Part 1 of 4) CF -1R AP-NE-&-P-A- DAMS 3122/20, :Y Project Title Date 7-T3.0 VLk- U0N-TA - NTA 0.9_A5 1l_ bo.le Project Address Building Permit # A_ driana_Gil (760) 404-7917 Documentation Author Telephone Plan Check/Date -Enam /P10 CA_CkMataZOTIB 1.5 Field Check/Date Compli-66ce Method Climate Zone TDV Standard Proposed . Compliance _(kBtu/sf-yr) Design Design Margin Space Heating 1.71 0.93 0.77 Space Cooling 100.44 90.91 9.53 Fans 14.42 ' 13.01 1.41 Domestic Hot Water 43.12 40.09 3.02 Pumps 0.00 0.00 0.00. , Totals 159.69 144.95 14.74 Percent better than Standard: .9.2% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: [X-] Single Family ❑ Addition Total Conditioned Floor Area: 351 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (S) 180 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 351 ft2 Fenestration: Average Ceiling Height: 10.0 ft Area: 95 ft2 Avg. U: 0.38 Number of Dwelling Units: 1.00 Ratio: 27.1% Avg. SHGC: 0.31 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area _HVAC -S System 35a -3 510 1 on Conditioned- -Setback- 2 -n/a OPAQUE SURFACES Insulation Act. 1 Gains Condition I ype Frame Area U -Fac. Gay. Gont. Azm. Tilt Y / N Status JA IV Reference Location / Comments .Root_ Wood_ _351-0-025.0_38_ a-0_0_ 90 18 Wall_ Wood_ X0.7_ 0_074_-R=19 _R=0_0_ --18.0_9D Wall_ Wood_ _18.5 0-07-4_ _R-19_ _R=0_0 _274 90 -Wall-Wood- X3.8. 0_0.7_4_ _11-1.9_ _R--O-O_ -0--90 Wall_ Wood_ 215_ -0-07A--R--19--R--O-O--90--90 IN IX X X X ❑flew ❑N.ew ❑New ❑ ❑blew 01-A18 Whole 0.9_A5 1l_ bo.le 0.9=A5 Whole New _0.9_A5 Whole 99A5 Whole ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ F-1 F-1 ' ❑❑ ❑❑ ❑❑ ❑❑ ❑❑ ❑❑ F-1 F-1 ❑❑ F-1 F-1 F-1 F-1 ❑❑ EnergyPro 4.3 by Energysoft User Number. 5553 Job Number: ADY392-0207 Paw:3 of 9 1 Y Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R ARNE & PATRICIA ADAMS = '`. 3/22/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments _1- W-tndow Front lS.� 48..0 _-34.01RC _028 _NERC 1.8D_ _9.0 New BET-TER-BUILT_Viny]Jow-E -NNhole 2 Window Left tM 30.0 0.340 NFRC 0_28 NFRC 270 90 New BETTER BUILT Vinyl low E Whole 3 Window Rear (N) , 12.0 0.650 NFRC 0_48 NFRC 0 90 New BECK, GLASS BLOCK 8x8x4 Whole 4 Window Rear (N)_ 5.0 0.340 NFRC 0_28 NFRC 0 90 New BETTER BUILT Vinyl low E Whole Run Initiation Time: 03122/07 11.21.19 Run Code: 1174591279 EnergyPro 4.3 by EnergySoft User Number. 5553 Job Number: ADY392-0207 Page:4 of 9 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Window Overhang # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Left Fin Right Fin Dist. Len. Hgt. Dist. Len.Hgt. 1 Bug Screen 0.76 8.0 6.0 2 Bug Screen 0.76 5.0 CO 3 Bug Screen 0.76 3.0 4.0 4 Bug Screen 0.76 2.0 2.5 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Type (sf) (in) Cap. Cond. R -Val. 2.0 0.1 2.0 2.0 0.1 2.0 2.0 0.1 2.0 2.0 0.1 2.0 JA IV Reference 2.0 2.0 2.0 -2-0 Condition Location/ Status Comments PERIMETER LOSSES Insulation Type Length R -Val. Location JA IV Reference Condition Location/ Status Comments Slab Perimeter 74 None No Insulation 26-A1 New Whole Run Initiation Time: 03122/07 11.21.19 Run Code: 1174591279 EnergyPro 4.3 by EnergySoft User Number. 5553 Job Number: ADY392-0207 Page:4 of 9 97 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R ARNE & PATRICIA ADAMS 3/22/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC Split System Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC Split System Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System. Name Length Diameter Thick. ; • a Water Heater System Name Type Distribution Rated Tank Energy # in Input Cap. Condition Factor Syst. (Btu/hr) (gal) Status or RE Tank Insul. Standby R -Value Loss (%) Ext. Standard gas 50 gal. or less Small Gas No Pipe Insulation - 1 50,000 50 New 0.60 _ n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Control # HP Tvpe Hot Water Piping Lentch (� In Plenum Outside Buried Add 1/2" Insulation tEMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: ADRIANA GIL Title/Firm: FERNANDO SILVA Title/Firm: Adriana Gil Address: 45-175 PANORAI14A DR TE. A-1 Address: 74-854 Velie Way Ste. #8 PALM DESERT 2 0 Palm Desert, CA 92260 ' Telephone: 760-799-2615 _ _ Lic. #: Telepho L 0 404-7917 03 ?=b%_o_�- (signature) (date) (sign tur Gate) Enforcement Agency Name: Title/Finn: Address: Telephone: (signature) (date) un Initiation Time* 03122107 11a2119 14un Code: 1174591279 ' EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number ADY392-0207 Page: 5 of 9 s Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R ARNE & PATRICIA ADAMS 3/22/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )aseo on ine aaequacy oT ine special /ustiTrcatron ano aocumentation suomtttea. Plan I Field The Roof "R-38 Roof (R.38.2x14.24)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan I Field The HVAC System "HVAC Split System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC Split System" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. / 4 I y l HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan I Field The HVAC System "HVAC Split System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC Split System" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. 4 i t EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY392-0207 Page:6 of 9 R i' Mandatory Measures Summary: Residential (Page 1 of 2) MF -IR I NOTE: Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTIONCheck or initial applicable boxes or check NA if not applicable and Included with the , permit application documentation. NIA DESIGNER ENFORCE- MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. 1:1 El El § 150(e): Installation of Fireplaces, Decorative Gas Appliances and'Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ Q ❑ b: outside air intake with damper and control, flue damper and control ❑ E ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑X ❑ § 150(g): Vapor barriers mandatory in. Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El nX Elt CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfikration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number., ADY392-0207 Page:7 of 9 a q ' ... ALA Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (") below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MEN7 Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1816 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive - ❑ R ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ R ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ © ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. J 7. Flexible ducts cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ -❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. ` 2. System is installed with: ' a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1'19(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. . § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ Q ❑ same lot shall be high efficacy luminaires (not including lighfirig around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more El E]❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro4.3 by EnergySoft User Number: 5553 Job Number: ADY392-0207 Page:8 of 9 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE ARNE & PATRICIA ADAMS 3/22/2007 SYSTEM NAME FLOOR AREA HVAC Split System 351 ENGINEERING CHECKS SYSTEM LOAD -71 Number of Systems COIL COOLING PEAK COIL HTG. PEAK 1 Heating System Output per System 32,000 Total Output (Stuh) 32,000 Output (Btuh/sgft) 91.2 Cooling System Output per System 18,600 Total Output (Btuh) 18,600 Total Output (Tons) 1.5 Total Output (Btuh/sgft) 53.0 Total Output (sgft/Ton) 226.5 Air System CFM per System 650 Airflow (cfm) 650 Airflow (cfm/sgft) 1.85 Airflow (cfmrron) 419.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 398 7,436 CFM I Sensiblel Latent 1 1 CFM I Sensible 398 7,436 1,217 162 7,686 0 675 612 0 0 0 0 0 0 0 0 0 675 612 8,787 1,217 8,910 York 1 1/2 TONS 13,497 2,853 32,000 Total Adjusted System Output 13,497 2,853 32,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm F Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 OF 69.1 OF 69.1 OF 179 115.4 OF Outside Air Q Supply Air Ducts 0 cfm 114.5 °F Supply Fan Heating Coil 650 cfm ROOMS 69.1 of 70.0 of Return Air Ducts (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 111.0/77.6°F 77.0/64.0°F 77.0/64.0°F 57.5/56.4°F cts Supply Air Du Outside Air 0 cfm Supply Fan Cooling Coil 58.4 / 56.8 OF 650 cfm 51.1% R.H. ROOMS 77.0/64.0 F ° 76.0 / 63.6 OF Return Air Ducts `S EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY392-0207 Pade:9 of 9