Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-3531 (CP)
do BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 05-00003531 Property Address: 48800 LEGACY DR APN: 658-130-011-1 -31379 - Application description: POOL - COMMERCIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 180902 Applicant: Architect or Engineer: Owner: CENTEX HOMES 2275 CORPORATE CIR #230 HENDERSON, NV 89074 Contractor: D CENTEX HOMES 1123 AURARIA PARKWAY DENVER, CO 80204 (720)279-6600 Lic. No.: 825943 VOICE (760) 777-701.2 FAX (760) 777-506'1 INSPECTIONS (760) 777-7153 Date: 10/06/05 4000 r,7 1 ASA - LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class:. A=B Ce a No.: 825943 ate: 1 Si - contractor:` 'i 1 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvernents are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.).. ( 1 I am exempt under Sec. , B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Itt` Lender's Address: FY LQPERiMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is .J�issued. <;:7J7 ave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier LOCKTON CO Policy Number WC832209709 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers'��yyompensation provisions of Section 1 3700 of the Labor Code, I��FF^J7trthwit�nply vlAwhje provisions. ,Nte:f U Applicant: - WARNX FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building constr ' n, and hereby authorize representatives ofis qco� mentioned prope ' spect urpo ` nt or Agent): LQPERMIT c Application Number . . . . . 05-00003531 Permit . . . ELEC-MISCELLANEOUS Additional desc 7 Permit Fee . . . . 67.50 Plan Check Fee 16.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/18/06 Qty Unit.Charge Per Extension BASE FEE 15.00 7.00 7.5000 ---------------------------------------------------------------------------- EA ELEC PWR APP >1 TO <=10 52.50 Permit . . . MECH POOL ' Additional desc.. Permit Fee . . . . 48.00 Plan Check Fee 12.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/18/06 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 11.0000 ---------------------------------------------------------------------------- EA MECH FURNACE >100K 33.00 Permit . . . PLUMBING Additional desc . . 3 Permit Fee . . . . 18.00 Plan Check Fee 4.50 Issue Date Valuation . . . . 0 Expiration Date 3/18/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 3.0000 --------------------------------------------------------- EA PLB GAS PIPE 1-4 OUTLETS ------------------ 3.00 Permit . . . BLDG POOL PERMIT Additional desc . Permit Fee. 923.00 Plan Check Fee 599.95 Issue Date Valuation .. . . . 180902 Expiration Date-. 3/18/06 Qty Unit Charge Per Extension BASE FEE, 639.50 81.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001 -UP 283.50 Permit WALL/FENCE PERMIT INV FEE Additional desc . ` Permit Fee . . . . 288.00 Plan Check Fee .00 LQPERMIT c LQPERN11T r { 4 Application Number . . . . . 05-00003531 F, Permit . . . . . . WALL/FENCE PERMIT INV FEE Issue Date . . . . Valuation . . . . 12902 Expiration Date 4/04/06 Qty Unit Charge Per Extension_ BASE FEE 90.00 11.00 18.0000 THOU BLDG 2,001-25,000 198.00 ---------------------------------------------------------------------------- Special Notes and Comments POOL/SPA #3-#4-#5 COMMERICAL POOLS AT CLUB HOUSE. PERMIT INCLUDES 109 LF. WROUGHT IRON FENCE & 479 LF. 6' HIGH BLOCK WALL (ORCO SYSTEM. HEALTH DEPARTMENT SHALL PERFORM ALL INSPECTIONS PRIOR TO CITY INSPECTIONS Fee summary Charged Paid -------------------- Credited ---------- Due ---------- ----------------- Permit Fee Total 1344.50 .00 .00 1344.50 Plan Check Total 633.33 .00 .00 633.33 Grand Total 1977.83 .00 .00 1977.83 LQPERN11T r { 4 ' Bin # { City of La Quinta 3 A Perm►(# Building 8t Safety Division / P.O. Box 1504, 78-495 Calle Tampico J�I La Quinta, CA 922S3 - (760) 777-7012 . Building Permit APPlication and Tracking Sheet Project Address: 7 Owner's Name: CPA A. P. Number: L �' Legal Address: I �5 CJQi7.� will( Description: ' City, ST, Zip: . Contra ctor. •��-,- Qe� 121 Telephone: ( Address., e ss. a�/ �(-c, lD Project Description: VCih, ST; Zip: � IL 471, 11 Tele hone: /0 319 N0 Pf� Q5 stateLic# : . .. .......................Lic. 65 O Arch., Engr., Designer: ,4LL of N Address:. 'LF (R ! elOe:LL tt/AI.L 02Co S 5/7M Citv, ST, Zip:. Telephone: � 7D . ,rF/eer ,ire 3 LS SPA wquz State- te. #• c" . Construction Type: ti . . a Occupancy: P nc - ' • Name of Contact Person:. , / / Jk� Pr " oe ct • eJ t) p(circle one):. • New Add'n Alter Repair De mo P /) Telephone # of Contact Person: r Sq. Ft.: #Stories: # Units: Estimated Val ue of Project: �tJ� APPLICANT: DO NOT WRITE BELOW THIS LINE � Submittal Req'd Recd TRACKING Plan Sets �• � n.� . Plan Check submitted a PER111T FE .S Structural Calu. G Reviewed, read} for corrections �0 ( �. Item Plan Check Amount Ttuss'Calcs. Deposit .Called Contact Person Plan Check Balanc Title 24 Calcs. Plans picked up 00F f Flood plain plan' Plans resubmitted . v Construction Grading plan 2" Review, ready for corrections/issue Mechanical '�y 5' Subcontactor List Electrics! 77n7NL OoippS Called Contact Person tum ink Grant Deed Plans picked up N $ II -OA -Approval Plans resubmitted S.M.I. IN IIOUSE:- ' Review, Grading Planning Approval ready for correctionsrssue Developer Impact Fee Called Contact Person A.f.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees COUNTY OF RIVERSIDE DEPARTMENT OF HEALTH ENVIRONMENTAL HEALTH SERVICES DIVISION POOL AND SPA PLAN CORRECTION Area # IV PROJECT NAME: Legacy Villas # 1 & 2 PROJECT LOCATION: Eisenhower & Coachella, La Quinta OWNER/CONTRACTOR: The plans are now approved subject to the conditions listed below: PLAN # IVP05-013 DATE: 4/11/2005 1. If the pool's air gap is located at a remote location outside the equipment enclosure, install a sight glass in the back wash line 2. Provide written approval from the Environmental Resources Division offices at 82675 Highway 111, Room 209 Indio CA: telephone (760)863-7000, for the sizing of the waste water discharge from the backwash for the pool(s):and/or spa(s) on these plans. This information must be provided prior to the commencement of any field or site inspections 3. Chlorinators are to be installed downstream of the heaters. An approved check valve is to be installed upstream of the chlorinator and downstream of the heater in the return line to the pool. 4. Spa suction anti -vortex covers are to be within two inches of the bottom of the spa. 5. There are to be no shrubs, trees planters, etc. within four feet of any pool or spa. 6. Provide effluent pressure gauges on the pool and spa equipment immediate downstream of the filter and upstream of the heater. They are to be within one foot of the same level as the influent gauge which may be found on the filter. 7. Provide separate waste discharge lines for each recirculation system. Do not join the spa and pool waste lines together. They may discharge into the same receptor. 8. The flow meter is to be located on a straight run of piping at least four (4) pipe diameters downstream of any bend or elbow and 10 pipe diameters upstream of any elbow. (Example: for a 2.5" pipe use 10 inches upstream and 25 inches downstream). 9. Replace the spa circulation pump model P6E6D205L'/ hp as shown, with model P6EW207L-1.5hp, to provide the minimum required turnover rate of 76 gpm. Plans show 52 gpm for the spa. (3/4 hp pump does not provide. 76 gpm) 10. Increase the spa skimmer suction pipe sizes from 2" to 2.5" to accommodate greater water flow from larger pump. See redline correction on pages W3a and W4 -CONSTRUCTION INSPECTIONS: Contact the Plan Checker for pre-gunite, pre -plaster and final inspections at least five (5) working days in advance. All three inspectionsmust be completed prior to issuance of a permit. - A FINAL INSPECTION MUST be made upon completion of all work including fencing, safety equipment, signs and support facilities such as restrooms. - APPROVAL to operate shall not be granted until the facility has passed the FINAL INSPECTION, and "APPLICATION TO OPERATE" has been completed and PERMIT fees have been paid. 'PLAN CHECK BY: Jerry Dubin I acknowledge the corrections note h r( and s ind construction: ` 1 Sign Company Phone (760) 320-1048 on the plans and agree to incorporate them during Date �� v E i COUNTY OF RIVERSIDE DEPARTMENT OF HEALTH ENVIRONMENTAL HEALTH SERVICES DIVISION I POOL AND..SPA PLAN CORRECTION Area # IV PLAN # IVP05-014 DATE: 4/22/2005 PROJECT NAME: Legacy Villas -features # 3, 4 & 5 PROJECT LOCATION: Eisenhower & Coachella, La Quinta OWNER/CONTRACTOR: Centex Homes The plans are now approved subject to the conditions listed below: 1. If the pool's air gap is located at a remote location outside the equipment enclosure, install a sight glass in the back wash line 3. Provide written approval from the Environmental Resources Division offices at 82675 Highway 111, Room 209 Indio CA: telephone (760)863-7000, for the sizing of the waste water discharge from the backwash for the pool(s) and/or spa(s) on these plans. This information must be provided prior to the commencement of any field or site inspections 4. Chlorinators are to be installed downstream of the heaters. An approved check valve is to be installed upstream of the chlorinator and downstream of the heater in the return line to the pool. 5. Spa suction anti -vortex covers are to be within two inches of the bottom of the spa. 6. There are to be no shrubs, trees planters, etc. within four feet of any pool or spa. 7. Provide effluent pressure gauges on the pool and spa equipment immediate downstream of the filter and upstream of the heater. They are to be within one foot of the same level as the influent gauge which may be found on the filter. 8. Provide separate waste discharge lines for each recirculation system. Do not join the spa and -pool waste lines together. They may discharge into the same receptor. 9. The flow meter is to be located on a straight run of piping at least four (4) pipe diameters downstream of any bend or elbow and 10 pipe diameters upstream of anv elbow. (Example: for a 2.5" pipe use 10 inches upstream and 25 inches downstream). 10. It is recommended to downsize the spa (feature # 5) chlorinator from Rainbow/Lifeguard model HC3315 to HC 300- 29 or equivalent. -CONSTRUCTION INSPECTIONS: Contact the Plan Checker for pre-gunite, pre -plaster and final inspections at least five (5) working days in advance. All three inspections must be completed prior to issuance of a permit. - A FINAL INSPECTION MUST,be made upon completion of all work including fencing, safety equipment, signs and support facilities such as restrooms. - APPROVAL to operate shall not be granted untiNhe facility has passed the FINAL INSPECTION, and "APPLICATION TO OPERATE has been completed and PERMIT fees have been paid. i PLAN CHECK BY: Jerry Dubin Phone (760) 320-1048 1 acknowledge the corrections noted herein and as indicated on the plans and agree to incorporate them during construction: Signature '. Company Date 'I u > F`y OF TNF' Owner CITY OF LA QUINT&, BUILDING & SAFE.DEPARTMEI T ___-777--,T012 T_Y INSPECTION REQUEST LINEb;; 777-7153 CENTEX HOMES ' Contractor. CENTEX HOMES _v Permit Number 05-3531 POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS 48-800 LEGACY DRIVE POOL/SPA #3,44, #5, AT CLUB HOUSE. PERMIT INCLUDES 109 LF. IRON FENCE & 479 LF. 6' HIGH BLOCK WALL TYPE OF INSPECTION I DATE I INSP. TEMPORARY POWER SETBACKS U/G PLUMBING / WASTE U/G ELECTRICAL/ GROUNDING FOOTINGS / STEEL CONCRETE SLAB DO NOT POUR CONCRETE UNTIL ABOVE SIGNED FRAMING (COMBINATION) Anil ;H FI Fr.TPlr.. COVER NO WORK UNTIL ABOVE SIGNED INTERIOR GYP. BD. DRYWALL EXTERIOR LATH GAS TEST SEPTIC ABANDONMENT SEWER CONNECTION SEPTIC / GREASE INTERCEPTOR MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS 7 06- U/G 6U/G PLUMBING JA U/G GAS / U/G ELECTRICAL PRE -PLASTER ALARMS / BARRIERS FINAL INSPECTIONS TEMP. USE OF PERMANENT POWER ELECTRICAL PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT. FINAL / JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING Legacy Villas .at La Quints Fence and wall analysis for features 3, 4 & 5 Wrought Iron fencing = 1.08'- 6" CMUwall=473'-8" 10 1 Note: all gates to have, 4x4 TS JAMB AND. HEAD. key activated gate locks CORNERS SHALL BE to isolate usage during MITERED AND GROUND closed periods of time. SMOOTH. PRIME AND PAINT ALL EXPOSED STEEL TOP OF GATE r 6,-0„ 18 GA. PERFORATED METAL SHEET — 1/2"0 HOLES MAX., PAINT TO N MATCH FENCE PANIC—BAR LATCH MECHANISM, SET MIN. 42" FROM FINISH SURFACE. 18. GA. METAL -7712" .o. X 24" KICK—PLATE. DEEP CONCRETE FOOTING SELF—CLOSING MECHANISM RECESSED IN SLAB WITH SEALANT. Legac Vdlas' at La (:2uj'nta T�)Pical FoolT=_nclosurcGate, DetaiI NTS 8'-6 114" 1'-5., Setback 20 1/2" (0.52m) to 30" (0.76m) Swim -Lift° Series Model Gallatin V-0" (0.30m) I • Designed for use on in -ground swimming pools and/or spas with 12 -inches (30.48cm) or more of overall depth (deck to floor) • Certified 400 -pound (181.44kg) operating load capacity, with a 1.5 -safety factor • ADA -ABA Compliant • Dual lift operating controls, allowing operation from the deck and/or the pool • Stainless steel superstructure, no paint to chip, no dissimilar metals to corrode, all metallic components are electro -polished and passivated, ensuring the ultimate in corrosion resistance • Patented pressure foot for stability during rotation Dual anchor points for added stability, easy to install. - even on existing facilities • Self-adjusting footrest • Comfortable fold down molded seat • Wide web seat belt with non -corroding cam lock buckle • Two armrests are provided; outer armrest flips up allows for horizontal transfer from a wheelchair • Water powered operation, only 55 -psi (379kPa) to lift 400 -pounds (181.44kg) • No batteries to lose charge and/or frequent replacement • No pinch points to cause injury • Lift transport wheels are provided • Five-year warranty �^� 7100 Spectrum Lane j Missoula, Montana 59808 �' �@�0�'%[$° 406.542.9781 800.791.8056 Fax: 406.542.1158 • . www.spectrumaquatics.com Swim -Lift' Series Model - Gallatin Catalog No: 27336 Literature No: SA 27336.205 ,. Swim -Lift G -a.11 a ti n_.��. w Installation a'nd Operation Manual r3 -TRU 7100 Spectrum Lane Missoula, Montana 59808 AquaticS® 800.791.8056 • 406.542.9781 --^� -� Fax: 406.542.1158 www.spectrumaqu.atics.com Swim -Lift@ Gallatin Thank you for purchasing the Swim -Lift®, Gallatin, from Spectrum Aquatics@, we appreciate your business. To assure -trouble free installation and operation of your Swim -Lift@ it is recommended that you read the entire Installation and Users Guide before attempting to install or operate the device. REMINDER: It is your responsibility to inspect product shipments, checking for the following: • Check the number of cartons/boxes/crates against the shipper's bill of lading. • Check the cartons/boxes/crates for freight, handling and/or suspected hidden damage: Refer to our published freight policy in for more informa= tion related to shipping. If you have any questions or problems related to your shipment we will do everything in our power to assist you. Please feel free to contact us at 800.791.8056. Our customer support team is there to help you. Spectrum employs heavy-duty shipping materials/car- tons/boxes/crates to protect product finishes and compo- nents from freight handling damage. Our quality control department guarantees that the proper quantities of items/components are packaged in each individual ship- ment, having a two -counter sign -off responsibility, insuring that there are no shortages of items/components. If freight damage or shortages of cartons/boxes/crates should occur you must file a claim with the carrier, noting damage or shortage on the bill of lading, before accepting shipment. It is Spectrum's desire to provide you with superior prod- ucts and services. Unfortunately we cannot control cir- cumstance related to the shipment of products beyond our freight docks. Box C Box A Box B Figure 1 Each Gallatin will arrive in three boxes being partially assem- bled. Before accepting the Gallatin shipment from the carrier, inspect for visible damage and match the contents of the boxes with those listed below. Step 1: Unpacking and Inspection Each Swim -Lift@ will arrive partially assembled in three boxes. Before accepting the Swim -Lift@ from the carrier, inspect for visible damage and/or match the contents with those listed below. . Box A: (1) Seat Assembly (1) Footrest (1) 50 Ft. Garden Hose Box B: (1) Cylinder Assembly (1) Seat Arm (1) Support Column (1) Valve Assembly Box C: (1) Support Leg Assembly (1) Base Stand Leg (3) Hardware/Donut Shims (2) Anchor Assemblies (Standard Swim -Lift@ Only) (2) Male Acme Bolts (1) Pressure Foot Assembly Tools Required The following tools will be required to complete assembly and installation: • Rotary impact drift (retrofit anchors only) • 1%2" diameter concrete drill bit (retrofit anchors only) • 1 1/2" diameter concrete core drill (retrofit anchors only) • Hydraulic cement or two-part epoxy • Socket wrench • 9/16" deep well socket (retrofit anchors only) • 3/4" socket or wrench • 9/16" socket or wrench • 1/2" socket or wrench • 15/16" open end wrench • 7/64" hex key (allen) wrench • Carpenters level • Marking pen or chalk (retrofit anchors only) • Spanner Wrench (provided) • Hammer (retrofit anchors only) • Torque wrench I Spectrum Aquatics® 800.776.5309 • www.spectrumaquatics.com NOTE: The two-piece collar on the valve handle holds the valve handle in place and may need to be reposi- tioned.. To move the collar, loosen the screws in the collar using a 7/64" hex key wrench. Move the collar so that it is just below the valve handle bracket and retighten the screws. See Figure 4. d) Attach the input/output hose (the hose attached to the center valve coupling on the valve) to the hose coupling at the base of the lift cylinder. See Figure 4. The valve is shipped with the input/output hose attached. Upper Valve Handle Knob' Two=Piece Collar e Valve Support Handle Column Cylinder Valve Handle Bracket Support Leg Valve Bracket ' Valve Input/Output Hose Coupling Figure 4 e) Attach the seat receiver to the seat pole Using one 3/8"-16 x 2-1/4" hex head bolt and one 3/8" acorn nut as shown in Figure 5. f) Slide the seat receiver tube over the seat receiver on.the seat arm. The seat receiver tube should slide up to the seat receiver gussets. The seat is secured in place by tightening the 1/2" bolt on the end of the seat receiver: Make sure this bolt is tight enough to prevent the seat from sliding off of the seat receiver. See Figure 5. g) Bolt the base stand to the anchors in the deck using two 1" diameter acme bolts as shown in Figure 6. Do not completely tighten the 1" diameter.ACME bolts at this time. 3 Seat Arm Seat Receiver Gussets 1/2" _ Hex Bolt— Seat Receiver------ ��' Chair Assembly Seat Receiver Tube Figure 5 h) Carefully insert the support leg into the base stand as shown in Figure 6. Push the lift assembly into the base stand until the leveler shoe is against the pool/spa wall. Pull the support leg out of the base stand slightly until two of the holes in the support leg line up with the two holes in.the base stand. Secure the support leg in the base stand with two 3/8"-16 x 2-1/4" hex head bolts and two 3/8" acorn nuts. Figure 6 Spectrum Aquatics® 800.776.5309 www.spectrumaquatics.com r.' NOTE If the. anchors are set a 20-1/2" from the pool/spa edge, only one hole in the base stand will be available for a bolt and the other will be blocked. It is acceptable in this situation to mount the support leg in the base stand using only one bolt. i) Attach the pressure foot to the support leg using two 3/8"-16 x 3-1/2" hex head bolts and two 3/8" nylock nuts as shown in Figure 7. Choose the appropriate bolt holes in the support leg and pressure foot so that the pressure foot contacts the deck and holds the lift in a straight up and down position left to right. If necessary, adjust the pressure foot leveler or remove one or two of the shims bolted to the bottom of the pressure foot to properly level the lift. IVOTE: It is best to secure the pressure foot to the Support Leg -With one bolt in one upper and one bolt in on lower m©Ating hole. Figure 7 j) Tighten the 1" acme anchor bolts using the supplied spanner wrench. Level the lift front to back, if necessary, by using donut shims between the base stand and each anchor. The donut shims can be used individually or in combination to level the lift. The donut shims can be used above the anchor foot plate or below as shown in Figure 8 to prevent the " acme bolts from bottoming out in the anchors. j) Adjust the leveler shoe at the bottom of the cylinder so that it contacts the pool/spa wall and I.ock it in place with the 5/8" jam nut. See Figure 6. NOTE. Use of the leveler shoe at the base of the cylin- der is not required for operation of the lift. The leveler shoe should be used if possible, but if its position is at the water line on a gutter it may not be possible adjust it to fit. This will not affect the operation of the lift k) Check that the cylinder is perpendicular to the deck1n all directions with a carpenters level. Adjust the pressure foot or change donut shims at each anchor. to level the lift. If the lift is not installed level and perpendicular it may lower the lifting capacity, reduce the operational life of the lift, or void the warranty. 1) Connect the water supply to the female garden hose coupling on the control valve. Read the 'Operation section before using your Swim -Lift@. Acme Bolt t Donut Shim can be 1 used above or below— l Acme Bolt r b Donut Shim can be Anchor used above or below Foot Plate Plate Figure 8 Figure 8 Foot Spectrum Aquatics@ 800.776.5309 • www.spectrumaquatics.com 4 Operators Guide Please read the Operation section completely before using your Swim -Lift®. , The Swim-LiftO is a water -powered handicapped lifting aid designed for use with water systems that have a 55 PSI rating. This lift will function with as little as 45 PSI water pressure. Optional pump kits are available for sup- plying a constant pressure of.55 PSI. Lifting capacities are based on a continual pressure supply without pres- sure drops incurred during peak demand periods of city water systems. The lifting capacity/pressure ratios are as follows: Pressure Lift Capacity 55 PSI 400 Lbs. 50 PSI 350 Lbs. 45 PSI 300 Lbs. Never exceed the maximum rated load of 400 lbs. Other lift models are available for loads in excess of 400 lbs. The outer chair arm flips up and back for ease of transfer from a wheelchair to the lift seat. In addi- tion, the stationary arm on the inside of the chair may assist in transferring. Use of the seatbelt is recommended for all users. To facilitate safe load- ing and unloading of inexperienced users, we recommend that an attendant always be'present. Instruct all facility on the proper use of the chair features and transfer procedure. The leg rest provided is adjustable in length. The leg rest is adjusted by pushing or pulling it in or out to the desired position. It can also be removed completely if it is not needed. 4. A lock pin is attached to the top of the cylinder to lock the chair in the fully raised position or rotated 180° over the pool. Push the pin through the piston rod (lower hole) to lock the chair in the fully raised position when the lift is not in use and/or when the water supply is turned off. Use the 1800 rotated lock pin hole (upper hole) to lock the chair in place when removing the lift from the anchors. A backflow preventer may be required on this lift to pre- vent contamination of the municipal water supply. Please 5. check your state and local codes to see if a backflow pre - venter is required. Lift Preparation: 1. Turn the control valve to the intermediate stop position and attach the water supply hose to the valve. Turn the water supply on. 2. With no weight on the chair, turn the control valve handle to the up position. Allow the chair to fully raise. 3. Turn the control valve handle to. the down position. Allow the seat to lower to a fully down position. Repeat steps 2 and 3 until a smooth operation is obtained. This process purges the air from the system and should not take more than 1 to 2 cycles to complete. 4. The lift is now fully operable. Lift Operation: 5 Lift operation is controlled through the use of the control valve. The valve handle turned clockwise will lower the chair and turned counter -clockwise will raise the chair. The chair will stop at any point along its travel if the valve handle is turned to the intermediate position. Excessive force is not required to tum the valve handle. Instruct the facility on the use of the control valve prior to operation. Keep other swimmers and children away from the lift at all times. Remove the lift from poolside when not in use if possible. A safety cover is available from Spectrum Aquatics@ to prevent tampering or unauthorized use of the lift. 6. To drain the water from the lift for storage: discon- nect the water source, tum the control valve to down, push the chair down, turn the valve to up, and push the chair back up. Repeat if necessary. This process will force the water from the cylinder, valve, and hoses for storage. Lift Maintenance The Swim -Lift® is virtually maintenance free since the drive component (water) is a self -lubricant. Providing it is installed correctly, the lift will furnish the user with many years of trouble-free use. The following should be per- formed periodically to ensure safe and dependable use.* Remove any discoloration with a 3M scratch pad. Rinse with water. Repeat these steps several times to passi- vate the stainless steel. Cleanup kits are available from Spectrum. Disengage the deck anchors and lubricate the acme thread nut with a small amount of Vaseline. Also, check that the inside bolt is tight. If it is loose or corroded, replace it immediately. Do not operate the lift until the bolt is replaced. Spectrum Aquatics® 800.776.5309 • www.spectrumaquatics.com J_' ot P.O. BOX 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 April 12, 2006 Mr. Mike Daley Centex Homes 1123 Auraria Parkway, Suite 400 . Denver, CO 80204 BUILDING & SAFETY DEPARTMENT (760) 777-7012 FAX (760) 777-7011 RE: Building Permits Extension Request — 48800 Legacy Drive. Dear Mr. Daley: I have reviewed your e. -mail letter dated April 5, 2006, requesting an extension for two commercial pools -being constructed at the above address under Building Permits #05-3530 and 05-3531. Our records. indicate the following status on these projects. Inspection status: Permits issued: 10/13/05 Last successful inspection: None 180 -day expiration date: 4/11/06 180 -day extension. date: 10/9/06 Under the provisions of California Building Code Section 106.4.4, your request is hereby granted. Because the Building Code specifies that "no permit shall be extended more than once," please be advised that unless the project passes its next required inspection,ori or before Monday, October 9, 2006, your building permits will expire automatically. Greg Butler Building & Safety Manager Greg tIt'r, From: sptaggart@centexhomes.com on behalf of mfdaley@centexhomes.com Sent: Tuesday, April 04, 2006 8:47 AM To: Greg Butler Subject: Legacy Villas Permit #s 05-3531 & 05-3530 Follow Up Flag: Follow up Due By: Wednesday, April 05, 2006 4:30 PM Flag Status: Flagged Greg, We are requesting an extension on Permit #s 05-3531 & 05-3530. These are permits for two Clubhouse .pools. at 48-800 Legacy Drive. The reason for this r',equest is due to a delay in beginning the Clubhouse due to processing and approval or various other permits. Thank you for Iyour cooperation. If you have any questions or concerns please do not hesitate to contact me. Thank you, Mike Daley V.P. Development & Operations Centex Destination Properties, West Division 41-865 Boardwalk, Suite 101 Palm Desert, CA 92211 (760) 862-1030 (760) 862-1040 Fax (760) 275-4022 Cell mfdaley@centexhomes.com 1 L