Loading...
06-0256 (RPL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Td�v 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 06-00000256--) Owner: Property Address: 44760 LIBERTY AVE BURGE JAMES G APN: 604-493-011-30 -24197 - 44760 LIBERTY_AVENUE Application description: POOL - RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 20000 Contractor: Applicant: Architect or Engineer: FPD SERVICES INC 43653 PARKWAY ESPLANADE LA QUINTA,-CA 92253 (760)324-7946 Lic. No.: 820132 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the B i ss and Profess' al Code, and my License is in full force and effect. License Class: C53 i n No.: 820132 Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not.intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY 1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date JAN 2 5 2006 1/17/06 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I c=at, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if 1 sho become subject to the workers' compensation provisions of Section 3700 of the Labor C e I shall for" p with those provisions. IIF --V Applican . WARNING: FAILURE TO SECURE WOR ERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL ENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to buil iqg construction,tl�and hC.elirreebbilY aau�thorize representatives of this county to enter upon the above-mentioned prop y 1 r 'nspection p V V v D-__� Signature (Applicant or Agent): M Application Number . . . . . 06-00000256 Permit BLDG POOL PERMIT Additional desc . Permit Fee . . . . 207.00 Plan Check Fee 134.55 Issue Date . . . . Valuation 20000 Expiration Date 7/16/06 Qty Unit Charge Per Extension BASE FEE 45.00 18.00 9.0000 ----------------------------- THOU BLDG 2,001-25,000 ----------------------------------------------- 162.00 Permit MECH POOL Additional desc .' . Permit Fee . . . . 26.00 Plan Check Fee 6.50 Issue Date Valuation _0 Expiration Date 7/16/06 -" Qty Unit Charge Per Extension BASE FEE 15.00 1.00 11.0000 ---------------------------------------- EAMECH FURNACE >100K ---------------'--------------------- 11.00 Permit ELEC_POOL PERMIT -RES Additional desc . Permit Fee 45.00 Plan Check Fee 11.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/16/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 30.0000 ---------------------------------------------------------------------------- EA ELEC PRIVATE SWIMMING POOL 30.00 Permit . . . PLUMBING Additional desc . Permit Fee . . 27.00 Plan Check Fee 6.75 Issue Date . . . . Valuation 0 Expiration Date 7/16/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 6.0000 EA PLB FIXTURE 6.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3..00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments FIBERGLASS POOL ONLY. ALARMS/BARRIERS LQPERMIT . Application Number 06-00000256 Special Notes and Comments SHALL BE IN PLACE PRIOR TO PRE -PLASTER INSPECTION. EQUIPMENT ENCLOSURE NOT INCLUDED.IN PERMIT. Fee summary Charged Paid Credited Due Permit Fee Total 305.00 .00 .00 305.00 Plan Check Total 159.05 .00 .00 159.05 Grand Total 464.05 .00 .00 464.05 i LQPERMIT J013 ADDRESS �fLt�(-PQ I91)er CITY OF LA QU2N�A SUB -CONTRACTOR LIST -PERMIT NUMBER 0 . ;2*OWNER .QrA e&Q-t, 6- _BUILDERqfP Sey-V(,-E:5 o3c- This form shall be nested on the job with the he BUildinq Inspection Card at all times in a conspicmous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this'. list must be approved the Building Division prior to commencement of work. Failure to comply will .result in a stoppage of work and/or the voidance building np.rmit- F:nr onnh nmnlirAhln f-1. all of bu I 771 -do Classification"tr'cto on a I -Staile.:.Contract6r"A Licen nsurance::-, SO City. BusinessLicense: Company Name 'Classification License Number Exp. Date Carrier Name (e.g. A, 0, C-8) (xxxxxx) (Xxtxx/xx) (e.g. State Fund, CalCompl Policy Number (Format Varies) Exp. Date (xx/xx/xx) License Number fxxxx) Exp. Date (xx/xxfxx) EARTHWORK (C-12) CONCRETE (C-81 L] 5LI 9, Hw 5 �1 0d,:1 5 Dy FRAMING (t -S)* 7 STRUCT.'STEEL MASONRY iC-29) MBINd (C -3 G) L .U L4+K PLASTER (C 135) DRYWALL (C-9) .P HVAC (C-20) ELECTRICAL, (C=10)' 10)* SHEET. METAL 10.43) FLOORING I GLAZING (C INSULATIOW(C-2): SEWAGh DIS PAINTINGIC-33) CERAMIC TILE (C-54) CABINETS (C-6) FEN.CIN*6 (.C-13) LANDSCAPING (C-27) (4 h. aOL, (C-53')- 1q,,z7-, 7 (-7jod i-5Li ZS- 3c,`� I F\ISV LEGACY REPORT � PFC-3608 Reissued January 1, 2004 4C==0.. W ICC Evaluation Service, Inc. SLolnesslRegional Orrice ■ 5360 Worlanan ME Road, Whitfiw, caffomia 90601 a (562) 699-0543 $S.Or Regkmal Office a 900 Montclair Road, Suite A. Birmingham00 , Alabama 35213 ■ (205) 599-98 WWW.ICC 9 Regional Office ■ 4051 west Fbssrnoor Road, Country Club Hats, Illinois 60478 ■ (708) 799-2305 Legacy report on the 1997 Uniform Building Code'rm DIVISION: 13—SPECIAL CONSTRUCTION Section: 13150—Swimming Pools FIBERGLASS ONE-PIECE SWIMMING POOLS AND SPAS VIKING POOLS, INC. POST OFFICE BOX 96 WILLIAMS, CALIFORNIA 95987 1.0 SUBJECT Fiberglass One-piece Swimming Pools and Spas. 2.0 DESCRIPTION 2.1 General: The swimming pools and spas consist of one-piece fiberglass construction shop -formed over a mold. The material is fiberglass reinforced plastic (FRP), a minimum of/, inch (6.4 mm) thick, composed of isophtalic resin, vinyl ester resin, fiberglass, and ceramic. The surface finish is a neo pentyl glycol gel coat. Viking Pools produces various styles of swimming pools and spas. When installed in accordance with this evaluation report, the pools and spas comply with applicable requirements of the following codes: * 2000 International Building Code® (IBC) * 1997 Uniform Building CodeT'A (UBC) * 130CA8 National Building Code/1999 (BNBC) * 1999 Standard Building Code® (SBC) * 2000 Intemational Plumbing Code® (IPC) * 2000 IAPMO Uniform Plumbing Code (UPC)* The overall pool dimensions, depths and capacities are shown in Table 1. For mini -pools, see Table 2; for spas, see Table 3. The units comply with ANSI/NSPI-5, specified in Section AG103.1 of the IRC, and IAPMO IGC -2000*, specified in the UPC. Models described in Table 4 can be placed up to 191/2 inches (49.5 mm) above ground. Vertical supports consisting of 1 -inch -by -l'/2 -inch -by -36 -inch -long (25 mm by 38 mm by 914 mm), Douglas fir, No. 2 wood members encapsulated in the FRP process at 41/2 -foot (1372 mm) intervals are required. These pools and spas may be placed with or without concrete or wood decking. Unless elevated portions of the units are protected from sunlight by soil berms, decking, etc., these portions must be coated with a UV -inhibiting opaque paint that is compatible with the laminate. All plumbing must comply with the IPC or UPC. Electrical work must comply with the code in effect at the construction site. The pool and spa must remain full of water at all times. A permanent sign, bearing the following statement, must be attached to the pumping equipment: Notice --The pool or spa is designed to remain full of water at all times. The pool shell may be damaged if the water level is allowed to drop below the skimmer. When appreciable draw -down is noticed or if it becomes necessary to drain the pool or spa, contact Viking Pools or its dealers for instructions. A permanent label must be installed adjacent to the above sign indicating the Viking Pool dealer's name, address and telephone number. 2.2 Installation: Viking pools and spas may be installed without a soil investigation by a registered design professional (RDP), subjectto the building official's approval, provided none of the following conditions are encountered at the site: 1. The existence of groundwater within the depth of the pool or spa excavation. 2. The existence of an uncompacted fill in contact with any portion of the pool or spa. 3. The existence of any expansive or adobe -type soils. 4. The existence of any soil types with an angle of repose that will not support the walls of the excavation at desired slopes. 5. Dangerto adjacent structures posed bythe proposed pool or spa location. 6. The existence of any cracks or openings in soil that would not confine sand bedding. If any of the conditions above is encountered, excavation must cease immediately. The specified conditions at the site must then be reviewed and recommendations made by the RDP. The building official must approve the RDP's report before work is continued. The pool or spa excavation profile must coincide with the contours of the pool. The overexcavation is approximately 6 *The Uniform Plumbing Code and IGC -2000 are copyrighted publications of the International Association of Plumbing and Mechanical Officials, 5001 East Philadelphia Street, Ontario, California 91761. ICC -ES legacy reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, .,a t any finding or other matter in this report, or as to any product covered by the report. copyright 0 2004 Page 1 of 6 Page 2 of 6 to 12 inches (152 to 305 mm) on the sides and ends. The overexcavation at the pool bottom is approximately 4 to 8 inches (102 to 203 mm). The backfill for the pool or spa bottom is a layer of 3 -inch -thick (76 mm) bedding sand matching the pool or spa profile. This sand layer is compacted using a manual tamper and water. The pool or spa is then set into place using a crane or excavator. A properly placed pool or spa must sit firmly on the sand and be within 1 inch (25 mm) of level. Simultaneous waterfall and sand backfill operations then commence. The sand is compacted with a tamper and water. The installer must ensure that the backfill level and water level are approximately the same throughout this procedure. After completion of the backfill and plumbing, the decking is placed. Decks are prepared as indicated in Figures 1 through 4: 1. Cantilevered concrete decks are constructed as noted in Figure 2 in all cases. 2. Cantilevered decks are constructed with brick or stone as noted Figure 3 in all cases. 3. Noncantilevered concrete decks are constructed as noted in Figure 1 in all cases. 4. Raised bond beams are constructed as noted in Figure 4 in all cases. 5. Aboveground installations are constructed as noted in Figure 5 in all cases. Barriers are required where pools are on premises of UBC Group R, Division 3, Occupancies or IBC Group R Occupancies. The barriers must comply with Appendix Chapter 4, Division I, of the UBC or Section 3109.4 of the IBC. 2.3 BNBC: Viking pools and spas may be used as public swimming pools or private swimming pools, in connection with Group R-3 Occupancies only. In addition to other requirements in this report, swimming pools used under the BNBC must satisfy the following items: 2.3.1 Location: Swimming pool and spa walls shall maintain distances from property lines required in Section 421.4 of the BNBC. 2.3.2 Construction: Requirements in Section 421.5 of the BNBC, concerning slopes, cleaning devices, walkways, steps and ladders, must be observed. 2.3.3 Water Supply: The water supply and drainage must comply with Section 421.6 of the BNBC. PFC-3608 2.3.4 Barriers: Barriers for private swimming pools must comply with requirements in Section 421.10 of the BNBC. 2.3.5 Diving Boards: Diving board distances and water depths must comply with Section 421.11 of the BNBC. 2.4 Identification: Viking pools and spas are identified by the following information imprinted on the top step of the pool or spa: manufacturer's name (Viking Pools, Inc., Viking Pools Central, or Viking Pools Northeast) and address, pool or spa model designation, a coded serial number and the evaluation report number (PFC-3608). The units also bear the label of the quality control agency, Columbia Research & Testing Corporation (AA -527). 3.0 EVIDENCE SUBMITTED Plans, fabrication and installation data, calculations and a quality control manual. 4.0 FINDINGS Thatthe Fiberglass One-piece Swimming Pools and Spas comply with the 2000 International Building Code® (IBC), the 1997 Uniform Building CodeTM (UBC), the 1999 Standard Building Code®, the BOCO National Building Code/1999 (BNBC), the 2000 International Plumbing Code®, and the 2000 IAPMO Uniform Plumbing Code, subject to the following conditions: 4.1 The construction and pool/spa installation comply with this report and the manufacturer's instructions. 4.2 Electrical and plumbing installation complywith the respective codes in effect at the construction site. 4.3 The pools and spas are installed bytrained dealers, agents or customers approved by Viking Pools, Inc., Viking Pools Central, or Viking Pools Northeast. 4.4 Clearances from slopes are observed as set forth in Section 1806.5.4 of the UBC, Section 1805.3.3 of the IBC or Sections 421.4 and 421.5 of the BNBC. 4.5 The pools and spas produced by Viking Pools Northeast, Inc.,176 Viking Drive Industrial Park, Jane Lew, West Virginia; Viking Pools Central, Inc., 10600 West Interstate 20 East, Midland, Texas; and Viking Pools, Inc., 121 Crawford Road, Williams, California, are manufactured under a quality control program with inspections by Columbia Research & Testing Corporation (AA -527). This report Is subject to reexamination in two years. Page 3 of 6 PFC-3608 TABLE 1 -POOLS SERIES LENGTH (ft. -In.) WIDTH (ft.4n.) Deep End (ft. -In.) DEPTH Shallow End (ft.4n.) CAPACITY (gal.) L 31-6 14-0 7-0 3-6 13,700 N 37-0 15-0 8-3 3-5 20,000 B 25.2 11-10 4-6 Uniform depth 8,100 K 34-0 15-0 8-3 3-5 16,000 MK 28-0 14-0 15-10 3-6 10,000 BL 40-0 11-10 4-6 Uniform depth 14,000 BFF 25-7 12-0 6-0 3-6 9,000 FF 30-0 14-0 6-0 3.6 12,000 BKD 24-0 12-0 5-0 3-6 6,000 SL 39-0 7.6 4-0 Uniform depth 6,500 BP 38-0 16-0 6-0 3-0 17,000 SFF 24-0 12-0 6-0 3-6 9,000 RS 30-0 14-0 6.6 3-6 12,500 GC 40-0 16-0 8-0 3-6 19,600 GS 35-0 16-0 5-10 3.6 15,000 RP 31-0 14-0 5-10 3-0 12,800 FP 25-0 12-0 5-5 3-0 6,000 CD 33-0 16-0 5-0 3-6 15,000 BPD 38-0 16-0 8-0 3.6 20,000 CP 31-0 12-0 5-0 3-0 10,500 MT 35-0 14-0 5-0 3.6 12,400 AC 39-0 16-0 6-0 3-0 16,700 OB 40--0--- 16-0 5-8 3-6 18,900 BN 40-0 16-0 8-0 3-0 22,000 TN 30-0 14-0 6-0 3-7 13,500 PS 40-0 16-0 7-0 3.6 23,000 LG 30-0 14-0 6-0 3-0 14,800 CC 35-0 16-0 6-0 3-0 15,000 AL 24-0 12-0 5-0 3.6 7,000 CL 30-0 12-0 6-0 3-0 10,000 MN 24-0 12-0 5-0 3-6 7,000 CY 30-0 14-0 1 6-0 3-0 12,500 BR 35-0 16-0 6-0 3.6 16,000 MR 40-0 1 16-0 8-0 3.6 1 22,000 ror an i mcn = zs.v mm, i toot = sus mm, i ganon =J. itis L. Page 4 of 6 TABLE 2—MINI POOLS PFC-3608 SERIES LENGTH (fL4n.) WIDTH (ft.4n.) Deep End (it-ln.) DEPTH Shallow End (ft.4n.) CAPACITY (gal.) SP 20-0 11-0 5-0 35 3,600 SK 20-0 10-0 5-0 3.6 2,750 MP 145 9.6 4-0 Uniform depth 2,500 MFF 14-0 8-6 4-0 Uniform depth 2,100 MLL 15.10 8-5 4-0 Uniform depth 2,200 MTK 16-0 9-3 4-0 374 2,300 HL 22-0 75 4-0 Uniform depth 3,500 WGA 18-0 85 6-0 Uniform depth 4,500 WGB 18-0 85 6-0 55 4,300 WGC 18-0 8-6 55 Uniform depth 4,050 WGD 18-0 85 5-0 5-0 3,850 WGE 18-0 8.6 5-0 Uniform depth 3,600 WGF 18-0 8.6 5-0 45 3,400 WGG 1 9-0 1 85 4-6 Uniform depth 1,200 WGH 9-0 8-6 5-0 Uniform depth 1,350 WGDXL 21-0 9-6 4-0 Uniform depth 3,000 WGDLXS 18-0 8-6 1 5-0 Uniform depth 2,800 ror se t mcn = z5.4 mm, 1 toot = :w5 mm, 1 gallon = 3.785 L. TABLE 3—SPAS SERIES SHAPE WIDTH OR DIAMETER (fL4n.) DEPTH (ft4n.) CAPACITY (gal.) RS Round 5-8 3-0 275 RSSW Round 5-8 3-0 275 RSSP Round 5-8 1-6 150 OS Octagonal 6-0 3-0 375 OSSW Octagonal 6-0 3-0 375 OSSP Octagonal 6-0 1-6 125 SS Square 6-6 3-0 295 SSSW Square 6-6 3-0 295 SSSP Square 6-6 15 150 LOS Octagonal 7-6 3-0 450 LOSSW Octagonal 7-6 3-0 450 LOSSP Octagonal 75 15 220 LRS Round 7-0 3-0 420 LRSSW Round 7-0 3-0 420 LRSSP Round 7-0 1-6 180 BOS Octagonal 8-0 3-0 475 BOSSW Octagonal 8-0 3-0 475 BOSSP Octagonal 8-0 15 270 CS Octagonal 8-0 x 12-0 3-0 700 CSSW Octagonal 8-0 x 12-0 3-0 700 CSSP Octagonal 8-0 x 12-0 1-6 430 RG Freeform 8-0 x 11-0 3-4 600 RGSW Freeform 8-0 x 11-0 3-4 600 RGSP Freeform 8-0 x 11-0 1.6 470 RY Rectangle 8-0 x 10-0 3-4 600 RYSW Rectangle 8-0 x 10-0 3-4 600 RYSP Rectangle 8-0 x 10-0 1.6 330 M Round 10-0 3-4 550 MSW Round 10-0 3-4 550 MSP Round 10-0 1-6 325 CB Kidney 8-0 x 10-0 3.4 525 CBSW Kidney 8-0 x 10-0 3-4 525 CBSP Kidney 8-0 x 10-0 1-6 275 LCS Rectangle 8-6 x 17-0 1 3-0 1 1,840 For w.. i mcn = zo.4 mm, i Toon = 3u5 mm, i gauon = J. M L. Page 5 of 6 PFC-3608 TABLE 4—ABOVEGROUND (19% INCHES MAXIMUM ABOVE GRADE) ror sr. 1 mcn = zo.4 mm. 6'X6'-W1.4XWL4 WIRE MESH OR 7A4HREBAR NO. 3,@2'-0- EACH WAY. POOLS FOR CLAY (ADOBE) SPAS ,Ir B MFF SK RS LOS CS M BFF MK SL RSSW LOSSW CSSW MSW BKD MLL SP RSSP LOSSP CSSP MSP FP MP AL OS LRS RG CB HL MTK MN OSSW LRSSW RGSW CBSW WGA WGB WGC OSSP LRSSP RGSP CBSP WGD WGE WGF SS BOS RY LCS WGG WGH WGDXL SSSW BOSSW RYSW WGDXLS SSSP BOSSP RYSP ror sr. 1 mcn = zo.4 mm. 6'X6'-W1.4XWL4 WIRE MESH OR 7A4HREBAR NO. 3,@2'-0- EACH WAY. SLOPED 1/4'.=1 9' FOR CLAY (ADOBE) SOIL ONLY. ,Ir LL, r — FOR CLAY (ADOBE) SOIL ONLY. 3' THICK COMPACTED SAND (TYPICAL) 4' MIN. THICK COMPACTED GRAVEL FOR CLAY <ADORE) SOIL ONLY. SAND e FIBERGLASS POOL SHELL IPA FIGURE 1—TYPICAL CONCRETE DECK ,ar FIGURE 2—TYPICAL CANTILEVER CONCRETE DECK 6'X6'-VI.4XVI.4 X MIN. VIRE MESH OR REBAR NO. 3, @ 2.0- EACH WAY. g _ FOR CLAY (ADOBE) SLOPED 1/4'-1' SOIL ONLY. T•.,. �.� 6. 1 ,r icr I FOR CLAY (ADOBE) 3' THICK CORPACTED SOIL ONLY. SAND (TYPICAL) 4' HIM. THICK COMPACTED GRAVEL FOR CLAY (ADOBE) SOIL ONLY. SAND ,ar FIGURE 2—TYPICAL CANTILEVER CONCRETE DECK Page 6 of 6 PFC-3608 6'%6' - V1.4 X V1.4 BRICK, FILLED BLOCK, a nun. BRICK VIRE MESH OR OR POURED CONCRETE e' OR NATURAL a•aaN. REBAR NO. 3.1 7.0' BACKFILLED DIRT STONE DECK EACH WAY. SLOPED 1/4'-1' V FOR CLAY (ADOBE) SOIL ONLY. y` �— IM:UAtUh� 6'X6' - v64 % V1.4 ' 7-a y -• a, VIRE MESH OR 12, 1It t MBAR NO. 3.®r-0' EACH AY. FOR CLAY (ADOBE) I/d'vl' SOIL ONLY. 10' FOR CLAY (ADOBE)" SOIL ONLY. 3' THICK COMPACTED SAND (TYPICAL) 4' M[N, THICK COMPACTED GRAVEL FOR CLAY 3' THICK COtPACTED WD08E) SOIL ONLY. SAND criPI'AU 4' MIK THICK CONPALTEO SAND GRAVEL FOR CLAY .FIBERGLASS (ADOBE) SOIL ONLY. POOL SHELL SAND �a FIBERGLASS L POOSMELL i FIGURE 3 --CONCRETE DECK WITH BRICK OR STONE MAXIMUM 19 117 FIGURE 4—TYPICAL BOND BEAM CONSTRUCTION MOUND DIRT OPTIIINAL AROUND POOL APPROX, 6 WOOD DECK FIGURE 5—TYPICAL ABOVE GROUND INSTALLATION I Bin # City of La Quinta Building u Safety Division Permit # P.O. Box. 1504, 78-495 Calle Tampico f La Quinta, CA 92253 -.(760) 777-7012 Building Permit Application and Tracking$hee t Project Address:Ce p L.1 1 gf Jr— Owners Name: _TI wl bUej A. P. Number: Address: q yl (Q,0 �� rg1lt Legal Description: a City' ST, Zip: hA Qu) n—oq GSA 9 a Contractor: f-Vp Smv I Cry i ,.Address: i City, ST, Zip: 'N7to Cr, _ 92'2A / • Telephone: ?S XLt ,'� `J State Lic. # : 79-O City.Lic. #: Arch., Engr., Designer: Address: City, ST, Zip: Telephone: Project Description: 17,1 x'3i' �gee_&,L rsS Copt✓ Construction Type: Occupancy: State Lic. #: :.Elm- - Project type (circle one): New Add'n Alter Repair Demo . Name of Contact Person: JA-SaJ Sq. Ft.: #Stories: #Units: Telephone # of Contact person: ') tz-d Total Permit Fees i ` 7 Estimated Value of Project: >-u t .o oo � APPLICANT: DO NOT WRITE•B%ELOW THIS UNE # Submittal Req'd Recd TRACMG' ' PERMIT FEES -Plan Sets • Plan Check submitted 1 Item Amount Reviewed, ready'for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans.picked up Construction Flood plain plan Plans resubmitted Mechanical Grading, plan' 2"4 Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '," Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees i PREPARED BY: FIBERGLASS POOLS of the DESERT 44-267 MONTEREY AVE 5TE C PALM DESERT, CA: 92260 760.324.7946. fax 760.773.2778 NOTES: 1. All doors from house Nnth access to the pool shall be equipped with an audible alarm. , + 2. All gates with access to the pool shall be Self closmg, self latchmg, and open out. 3. 5ee ICBG report NPFC-3608 I t G' Rear P.L. Wall i f 3' Retaining Wall - .House Wall 3'-0" 0 / d Tapered pool,wv ` o F, J EX15tincg Bottom of Footing o9sG`` ,• Deepest point of pool ` I Surcharge Detail A NEW FIBERGLA55 POOL FOR: LIBERTY AVE. Mr. * Mr5,. Jim Burge Liberty Ave., La Quinta, Ca. 92253 5� I1EET: INSULATION CERTIFICATE This Is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building located at: 44-760 Liberty Avenue, Lot 30, Monticetio-Heritage, La Quints, California CEILINGS. TYPE: BLOW MANUFACTURER: CERTAINTEED . THICKNESS: R-38 WALLS: TYPE: BATTS MANUFACTURER: CERTAINTEED THICKNESS: R-13 GENERAL CONTRACTOR: CENTURY CROWELL COMMUNITIES LICENSE # 7! ylaTr BY: LA& TITLE: 45�aw Sy.�ri PARAGON SCHMID BUILDING PRODUCTS, A MASCO COMPANY LICENSE 0 632072 B : TITLE: ADMINISTRATIVE ASSISTANT DATE: 12/12/2002