BWFE2014-10757e8-495 CQLLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
BWFE2014-1075
Property Address:
81600 MACBETH ST
APN:
767800063
Application Description:
GARDEN WALL 235 LF
Property Zoning:
Application Valuation:
$6,345.00
Applicant:
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Tihf 4 44umto
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
OCT 24 2014
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provis'ons of Chapter
9 (commencing w, h Section 7000) of Division 3 of the Business and Pr essions Code,.
and my License' in full force and effect.
License Class: icense No.: 728102
Date: Contractor
� M
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt fro,
ro the Co actor's State
License Law for the following reason (Sec. 7031.5, Business an essions Code:'Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
.basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's Ad
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS(760)777-7153
Date: 10/22/2014
Owner:
IOTA GRIFFIN
4675 MACARTHUR CT NO 1550
NEWPORT BEACH, CA 0
Contractor:
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
(949)349-8269
Llc. No.: 728102
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to he workers'
compensation laws of California, and agree that, if I should b e su ect to the
workers' compensation provisions of Section 00 of th abor Code" I shall forthwith
c
omply with th e r isions.at"'e: Ap�l t:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATIOOOVERAGEIS NLAWFUL,
AND SHALL SUBJECTAN EMPLOYER TO CRIMINAL PENALTS UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDIT OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose berefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and st to laws relating to ilding
construction, and hereby authorize representatives of this ty to enter th above
mentioned prop rty f r inspection purposes.
��<
Dat C/ Signature (Applicant or Age6t): `
� J�
FINANCIAL •
DESCRIPTION ACCOUNT
1
QTY AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE 101-0000-20306
0
$1.00
$0.00
a PAID BY METHOD'
RECEIPT #
CHECK #
CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WALL/FENCE - EA ADDITIONAL 50 LF
101-0000-42404
0
$91.36
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
" CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WALL/FENCE - FIRST 100 LF
101-0000-42404
0
$47.86
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WALL/FENCE - FIRST 100 LF PC
101-0000-42600
0
$60.91
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forFENCE OR FREESTANDING WALL• $200.13 $0.00
• ••
Description: GARDEN WALL 235 LF
A11913111rahl.
Type: WALL/FENCE
Subtype: Status: SUBMITTED
Applied: 9/15/2014 MFA
Approved:
Parcel No: 767800063 Site Address: 81600 MACBETH ST LA QUINTA,CA 92253
Subdivision: TR 32879
Block: Lot: 138
Issued:
Lot Sq Ft: 0
Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $6,345.00
Occupancy Type: Construction Type:
Expired:
No. Buildings: 0
No. Sturies: 0 No. Unites: 0
Details: 235 LF GARDEN WALL [PROTO II SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR
TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES.
Printed: Wednesday, October 22, 2014 3:56:28 PM 1 of 2
§?srsrems
A11913111rahl.
CHRONOLOGY
CONDITIONS
NAME TYPE
NAME
ADDRESSI
CONTArTS
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO
CA
92656
CONTRACTOR
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO
CA
92656
OWNER
IOTA GRIFFIN
4675 MACARTHUR CT
NO 1550
NEWPORT
BEACH
CA
0
FINANCIAL
•
DESCRIPTION ACCOUNT QTY
AMOUNT
PAID PAID DATE
RECEIPT # CHECK # METHOD PAID BY CLTD
BY
BSAS SB1473 FEE 101-0000-20306 0
$1.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION
BSA:
$1.00
$0.00
Printed: Wednesday, October 22, 2014 3:56:28 PM 1 of 2
§?srsrems
DESCRIPTION I ACCOUNT I QTY I` AMOUNT I PAID I PAID DATE I RECEIPT # CHECK # METHOD PAID BY CLTD
BY
WALL/FENCE - EA
101-0000-42404
0
$91.36
$0.00
SEQID
INSPECTION TYPE
INSPECTOR
ADDITIONAL SO LF
INSPECTIONS
COMPLETED RESULT
DATE
REMARKS
NOTES
BOND BEAM
WALL/FENCE - FIRST
101-0000-42404
0
$47.86
$0.00
FOOTINGS
100 LF
WALL/FENCE - FIRST
101-0000-42600
0
$60.91
$0.00
100 LF PC
Total Paid for FENCE OR FREESTANDING WALL $200.13 $0.00
PARENT PROJECTS
REVIEWS -
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES
DATE
BOND INFORMATION
ATTACHMENTS
Printed: Wednesday, October 22, 2014 3:56:28 PM 2 of 2 srsrEMS
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
INSPECTIONS
COMPLETED RESULT
DATE
REMARKS
NOTES
BOND BEAM
FINAL*"
FOOTINGS
PARENT PROJECTS
REVIEWS -
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES
DATE
BOND INFORMATION
ATTACHMENTS
Printed: Wednesday, October 22, 2014 3:56:28 PM 2 of 2 srsrEMS
6" (6-0" TO 6'-8'� PROTO II - EXPOSURE C - DIP FOOTING
DESIGN CRITERIA (PER 2013 CBC):
1. ALLOWABLE SOIL .BEARING PRESSURE PROTO II FENCE WALL
= 1000 PSF MIN.
2. ALLOWABLE SOIL PASSIVE PRESSURE
= 150 PCF MIN.
3. SEE SHEET B, C, & D PRIOR TO
START OF CONSTRUCTION. 6" STD. HOOK
6" CAP BLOCK PER
/—
SHEET C
STEEL PLATE TO BEAR
FULLY ON CENTER WEB
OR END FACE SHELL -
SIZE PER SHEET C.
00
r
I
I
I
I
I
I
I
8"
CONT
PER
NO COLD JOINTS ---
PERMITTED BETWEEN DIP ?
AND SETTING PAD
N
HORIZONTAL JOINT
2:1 SLOPE
M
REINFORCING TOP 2
12" TO 36"
COURSES BELOW PLATE
6" TO 11"
AND AT 24" O.C. BELOW
VERTICAL FOOTING
3'-1"
REINFORCING AT 6'-8"
-POST TENSION (PT)
ROD SEE SHEETB' FOR
FENCE, USE 1 #4 IN
f10 SCOle
CENTER OF DIP
ROD SPECS - CENTER
IN WALL
PROTO II FENCE WALL
FINISHED GRADE
_#4 CONTINUOUS
AT HOOK
z
2 1
MAX
CONT. CONCRETE
SETTING PAD =
'SEE SHEET D
I
I
I
I5-0" TO
DAYLIGH-r MIN.
LINE OF DIP
FOOTING BEYOND
3'-0"
V
16" MIN
FOR SIDEYARD RETURN WALLS
WHERE DRAINAGE SWALE
OCCURS, INSTALL DRAINAGE
BLOCK AT SWALE AT GRADE.
POST TENSION (PT)
ROD SEE SHEET B
CONCRETE DIP FOOTING
DIP MAY BE OVER
EXCAVATED AS SHOWN -
FILL WITH COMPACTED
FILL.OR CONCRETE
DIP DEPTH AT TOP OF
2:1 SLOPE
SETBACK - FACE OF FOOTING
TO TOP DF SLOPE
MIN. DEPTH 'D'
DIP FOOTING
12" TO 36"
2'-4"
6" TO 11"
2'-11"
3" TO 5"
3'-1"
FENCE WALL SCHEDULE AT LEVEL SOIL
'H' DESIGN WINO I PT ROD DIP
MAX
EXP/ P+# P•AGN+
6'-0"
CAT 110 6'�cQ'i
C AT 1 0 BU LDIieo
CAT1 0 _ Qs ---
6'-8"
C AT 1'0 a
C AT 1 0 --
C AT 120 I 1
tF
SAFETY IDEPT.
ROTO II ISTANDARD
7-IFCA OUIN11A, CA
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE
vr+I lz "77�
JOB NUMBER
O ��
SEALED ON
14-115-9155
/
f10 SCOle
TRACKING N
-DRAWN
w S 40 5 m
14-115-8964
TMH
°GC
A R U S O
PROTO-II TM WALL SYSTEMS
DATE
ENGR
S *
TURLEY
S ae�'^
WWW.PROT02.COM
08.19.2014
JAC
S'j9 TROCTU�P \Q
Yz '; ) SCOTT
W
41800 CASCADES COURTEHEC LA. CA 92591
OTTO
PACKAGE
SHEET
OF CA��
INC.
om
PH® (951) 694-3793 — goryotlo®pro(oi.com
ONLY CERTIFIED INSTALLERS)
S1.2
www.ctsoz.com
a...
»»»
{MAY BE INSTALLED BY APPROVED AND
4'. 6". AND r THICK POST-TER90REO MASONRY WALLS
�-•1
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE
GENERAL STRUCTURAL NOTES
I. SOIL SHALL BE FIRM AND COMPACTED PRIOR, TO PLACEMENT OF CONCRETE. PRIOR TO FOUNDATION EXCAVATION, USER SHALL
VERIFY THAT SITE SOILS CONDITIONS MEET OR EXCEED AN ALLOWABLE PASSIVE BEARING PRESSURE OF 150 PSF/FT (SOIL
CLASS 4 OR BETTER AS DEFINED BY THE CBC) STARTING AT THE TOP OF GRADE(I.E. NO TOP SOILS ARE NEGLECTED FOR .
PASSIVE) AND A MINIMUM ALLOWABLE BEARING PRESSURE OF 1000 PSF.
2. FOOTINGS TO BE LEVEL. IF GROUND, SLOPES THE FOOTING SHALL BE STEPPED. EACH STEP SHOULD BE PROPER HEIGHT TO FIT
BLOCK TYPE USED. ALL EXCAVATIONS SHOULD BE CLEAN AND CONTAIN NO LOOSE EARTH OR FOREIGN MATTER.
3. SEE SHEET A FOR EXPOSURE, WIND SPEED, POST TENSIONED ROD SPACING, FOOTING SIZES, ETC. USER IS RESPONSIBLE TO
VERIFY REQUIREMENTS WITH BUILDING DEPARTMENT AND OWNER. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE
APPROVED SITE PLAN AND APPLICABLE CODE OR JURISDICTION REQUIREMENTS.
4. SOIL BELOW FOUNDATIONS SHALL BE WELL DRAINED AND NON -EXPANSIVE. USE CONCRETE WITH A MIN. STRENGTH OF 2,500 PSI
- TYPE II CEMENT (TYPE V WHERE REQUIRED BY OWNER, SOILS ENGINEER OR JURISDICTION). CONCRETE SHALL BE A MIN. OF
48 HOURS OLD PRIOR TO FINAL TENSIONING ALL. ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED BY SUITABLE MEANS
DURING PLACEMENT.
5. LAP REINFORCING STEEL: LAP = 32" FOR 14 BARS IN CONCRETE.
6. CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 AND BE 2,000 PSI MIN. (F'M DESIGN CRITERIA FOR BLOCK IS
BASED ON 2000 PSI). BLOCK SHALL BE A MIN OF 7 DAYS OLD PRIOR TO ROD TENSIONING. STANDARD HEAD AND BED JOINT
BLOCKS WITH MORTAR MAY BE USED OR INTERLOCKING BLOCKS MAY BE USED. BLOCKS SHALL BE LAID IN RUNNING BOND.
7. MORTAR SHALL BE TYPE S, 2000 PSI MIN. MORTAR MUST BE A MIN. OF 4 HOURS OLD PRIOR TO INITIAL' TENSIONING AND 24
HOURS OLD PRIOR TO FINAL TENSIONING.
8. FIRST MASONRY COURSE MAY BE SET IN FRESH CONCRETE FOOTING.
9. REINFORCING REBAR SHALL CONFORM TO ASTM A641; Fy = 60,000 PSI.
10. PROTO-1I HARDWARE IS DEFINED AS: TENSION RODS, BEARING PLATES, COUPLERS, NUTS, ALL THREADS, DIRECT TENSION
INDICATORS (A DIRECT TENSION INDICATOR (DTI) IS A COMPRESSIBLE WASHER) AND PLASTIC SADDLES. ALL OF THIS HARDWARE
SHALL BE SUPPLIED BY ONLY AN APPROVED PROTO-11 LICENSEE TO THE CERTIFIED INSTALLER. POST TENSION RODS SHALL BE
7/16" DIAMETER WITH 1/2" ROLL THREADS CONFORMING TO ASTM A641 (FY = 60000 PSI) AND HAVE STEEL CHEMISTRY SO
THAT BENDING AND THREADING CAN BE ACCOMPLISHED WITHOUT DAMAGE TO THE POST TENSION ROD. AREA OF POST TENSION
ROD = .1503 SQUARE INCHES. BEARING PLATES ARE 1/4" THICK (Fy=50 KSI) SEE SHEET C FOR DIMENSIONS. 1/2" COUPLERS
PER ASTM A563 GRADE A, AND THE COUPLER MUST FULLY ENGAGE THE UPPER AND LOWER ROD, FULLY ENGAGED IS DEFINED
AS 1/2" MIN. INTO COUPLER. 1/2" NUTS ARE TO BE GRADE 8, PER ASTM A325. 1/2" ALL THREADS PER ASTM A307, GRADE
60. DIRECT TENSION INDICATOR (DTI - COMPRESSIBLE WASHER) IS MANUFACTURED PER ASTM F959. PLASTIC REBAR SADDLES
ARE NON-STRUCTURAL.
11. HORIZONTAL JOINT REINFORCING SHALL BE 9 GAGE DIAMETER WIRE AND PLACED PER SHEET A AND CONFORM TO ASTM A82
LADDER TYPE, 9 GAGE DIAMETER. LAP JOINT REINFORCING ONE FULL CROSS SQUARE (6" MINIMUM LAP).
12. IN LIEU OF FULL HEIGHT RODS, CONTRACTOR MAY USE SHORTER RODS, 1/2" COUPLERS AND STRAIGHT RODS THREADED BOTH
ENDS FOR ADDITIONAL LIFTS. RODS SHALL HAVE A MIN. OF 3" 'L' HOOK, WITH 1/2" NUT AT END OF TENSION ROD WHERE
EMBEDDED IN FOOTING.
13. VERTICAL CONTROL JOINTS TO BE PLACED AT MAX. 36' O.C. IN ALL NON -STUCCOED WALLS AND 20' ON CENTER IN STUCCOED
WALLS WITH CLEAN VERTICAL BREAK OF ALL MATERIALS. POST TENSION ROD SHALL OCCUR WITHIN 12" OF END OF WALL AND
12" EACH SIDE OF CONTROL JOINT.
14. NO COUPLERS MAY OCCUR DIRECTLY BELOW AND IN CONTACT WITH THE BEARING PLATE. NO BOND BEAM BLOCK MAY BE USED
AT PLATE/TENSION LOCATION.
15. TENSION RODS MAY BE STABBED INTO WET CONCRETE OR TIED IN PLACE AT CONTRACTOR OPTION; AT CONTRACTOR OPTION,
VERTICAL REBAR MAY BE STABBED DOWN INTO THE DIP.
16. A PROTO-11 DTI (COMPRESSIBLE WASHER) SHALL BE INSTALLED AT EVERY TENSION ROD BETWEEN THE BEARING PLATE AND NUT
WITH THE DTI "TABS" FACING UP AGAINST THE BOTTOM OF THE NUT. THE SPECIAL DEPUTY INSPECTION REQUIRED AT TIME OF
FINAL TENSIONING BY A DEPUTY INSPECTOR SHALL VERIFY FINAL TENSIONING TO 6,000 POUNDS BY 1 OF 2 METHODS; METHOD
1; VISUAL INSPECTION OF DIRECT TENSION INDICATOR (DTI), TABS FACING UP AND COLLAPSED AGAINST NUT WITH NO LIGHT
LEAKAGE BETWEEN THE PROTO-11 DTI AND BOTTOM OF NUT. METHOD 2: USE OF A CALIBRATED TORQUE WRENCH TORQUED TO
55 FT -LBS. (DTI MUST STILL BE PLACED WITH METHOD 2. NO VISUAL INSPECTION OF DTI REQUIRED WHEN USING METHOD 2).
INSPECTOR SHALL OBSERVE THE USE OF THREAD LUBRICANT, THE POSITION OF PLATE ON BLOCK, AND INTEGRITY OF MORTAR
JOINTS, AND PROVIDE A SIGNED REPORT TO ALL REQUIRED PARTIES. PROTO 11 MASONRY DESIGN IS BASED ON THIS SPECIAL
INSPECTION.
17. POST TENSION ROD SPACING IS INDEPENDENT OF DIP SPACING. TOLERANCE FOR DIP SPACING IS ±12" BUT THE NUMBER OF
FOOTINGS MUST REMAIN THE SAME FOR A GIVEN LENGTH OF WALL. PO III ROD-SPAGa-NG-%L{RA S t8" BUT
THE NUMBER OF RODS FOR A GIVEN LENGTH OF WALL MUST REMAI THF,-pAMEn� LA QUINTA
18. SEISMIC DESIGN CRITERIA: Ss=2.0, Sr=0.749 SOIL CLASS=D (ASSUMED) RISOCIATEG RY I.
19. FOUNDATION INSPECTION PRIOR TO PLACEMENT OF CONCRETE INCLUDE (jqQft0!�f}j&QbAOWVf RW q SIZE/DEPTH
AND CLEANLINESS OF77�
DDITIONAL SPECIAL INSPECTION A REQUIRED "U 1SDtC4T
RVED
FOR CO�TTRU: jC�TO II TANDARD
LA QUINTA CA
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORDS SEAL IS AFFIXED WITH WRITTEN SIGNATURE
Q F SS O
k,� K!
DATE
JOB MBER
-_773-9155
S p,'i
O � SEALED
G y
C
ON
co
S40 5
m
8/1`14
n0 Cole
TRACKING #
DRAWN
14-115-8964
TMH
*
CARUSO
=tee PROTO-II TM WALL SYSTEMS
DATE
ENGR
S
s� TRUCTV��Q
TURLEY
WWW.PROT02.COM
1 41800 CASCADESRT
08.19.2014
JAC
PACKAGE
SHEET
�000^�
:. -. SCOTT
INC. "o ecce TCO 0 EOULA, CA 92591
OF `WFO�
CA
www.CISOZ.COm
�� PHI (951) 694-3793 - goryotlo�roloii.com
a (NAI ONLI BE INSTALIEO BY APPROVED CERTIFIED
S1.2
i
v AND INSTALLERS)
» A . 6 . AND 8' THICK POST -TENSIONED MASONRY WALLS
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORDS SEAL IS AFFIXED WITH WRITTEN SIGNATURE
TOP OF PROTO II WALL
KEY NOTES:
1.
POST TENSION ROD.
S
2.
NUT.
3.
DIRECT TENSION INDICATOR (DTI).
4.
BEARING TOP PLATE.
5.
COLLAPSIBLE TABS.
6.
MINIMUM TENSION TO BE 6,000 LBS LOAD AND
CONFIRMED BY ONE OF TWO METHODS PER
NOTES "B" & "C" BELOW.
7.
FILL CAP BLOCK WITH MORTAR. IMMEDIATELY
\ /
"FLIP" ONTO ROD. COMPLETELY COVER NUT, ROD
AND PLATE WITH MORTAR.
S.
CAP BLOCK OF SUFFICIENT SIZE TO COVER
PROTO 11 �5�
PLATE AND ROD.
9.
CONTINUOUS HORIZONTAL JOINT REINFORCING.
10.
CENTER WEB OR END FACE SHELL BELOW.
(3) PLAN VIEW
11.
STEEL PLATE SIZES:
/
A. 4" PROTO 11:1/4"x3"x6"
B. 4" SLUMP PROTO II:1/4"x2 1/2"x6"
l2�
C. 6" PROTO 11:1/4"x4 1/2"x6"
0. 6" SLUMP PROTO 11:1/4"x4"x6"
STEEL PLATES TO BE PLACED AT THE EDGE OF
THE CELL SO THAT THE PLATE BEARS FULLY ON
THREE SIDES.
12.
00 NOT USE BOND BEAM BLOCK AT BEARING
(6)
PLATE LOCATIONS.
(8)
(7)
A. PROTO 11 DTI TO BE USED AT EACH TENSION ROD.
TABS FOR DTI SHOULD FACE UP AGAINST BOTTOM
OF NUT. TABS WILL COLLAPSE (NO LIGHT PASSES
BETWEEN BOTTOM OF NUT AND DTI) WHEN PROPER
TORQUE OF NUT HAS BEEN ACHIEVED.
B. AS ALTERNATE . TO VISUAL INSPECTION OF TABS,
INSPECTION OF NUT TORQUE MAY BE ACHIEVED BY
USE OF A CALIBRATED TORQUE WRENCH. TORQUE
NUTS TO 55 FT -LBS. DTI STILL MUST BE PLACED ON
'ROD IF USING TORQUE WRENCH METHOD. SEE
GENERAL NOTE ON SHEET B.
C. SPECIAL DEPUTY INSPECTOR WILL PERFORM' A
VISUAL INSPECTION WHEN USING THE DTI METHOD TO
CONFIRM THE OTI IS COLLAPSED WITH NO LIGHT
LEAKS BETWEEN THE TABS AND BOTTOM OF NUT.
IF USING TORQUE WRENCH METHOD, DEPUTY
INSPECTOR WILL CONFIRM WALL IS TORQUED TO 55
FT -LBS. NO VISUAL INSPECTION OF DTI IS REQUIRED.
D. INSTALLER MUST HAVE SPECIAL DEPUTY INSPECTION
OF TENSIONING PERFORMED BY ONE OF THE TWO
METHODS NOTED ABOVE. SPECIAL DEPUTY INSPECTOR
TO PROVIDE A COMPLETEDBFP-0R4-4e-LlsMD"'j
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE.
FOOTING ELEVATION AT POST TENSION ROD
PROTO II FENCE WALL
Y
THICKENED FOOTING TO PROVIDE
3" MIN. COVER AS REOUIRED
.AROUND ANCHOR BOLT AND NUT
ELEVATION
x
7/16" DIA. POST TENSION RODS
(PT) SEE SHEET B CENTER IN
WALL
li
THICKENED FOOTING TO PROVIDEI�
3" MIN. COVER AS REQUIRED
AROUND ANCHOR BOLT AND NUT
—\
L- — — — _ -
8"
SECTION
Y
CONCRETE SETTING PAD
7/16" DIA. POST TENSION RODS
(PT) SEE SHEET B CENTER IN
WALL
CITY O6 LA QUINTA
BUILDING & SAFETY DEPT.
% PP ROkQ I STAN
O " i
FOR CSTR �. CA
pJ K 1 �
y
Z
Lu S405 m
S *
sT T'4UCTV�P �P
9T ���
FOF `\F
CA
SEALED ON
8/114T07CKING
CARUSOOf-
TURLEY
b e SCOTT
INC.
WWW,CISO$.COrtT
_
DATE
n0 SC
_ PROTO-II TM WALL SYSTEMS
- WWW.PROT02.COM
47800 CASCADES COURT TEMECUTA, CA 92591
8. W3� .. ` ATTN: GARY OTTO )
�� aav PHy (95l) 694-}793 - goryotloOprotoii.tom
1 riNH MAY ONLY BE INSTALLED BY APPROVED AND CERnnED INSTALLERS
»»j J. 6'. ANDB, THIO( POST-TEN$IONEO MASONRY WALLS
JOB NUMBE
— —Flb
#
14-115-8964
DRAWN
TMH
DATE
08.19.2014
ENGR
JAC
PACKAGE
S1 ��
SHEET
D
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE
LEGEND
PROPERTY UNE
_ PUBLIC UTILITY
EASEMENT
RIGHT—OF—WAY
(R/W)
---W— WATER MAIN
—" "— ---� SEWER MAIN
GARDEN WALL
TOP � TOP. OF SLOPE
Toe TOE OF SLOPE
P RR CONDITIONING
TOP AD
CONCRETE STOOP
F1 SIDEYARD GATE
k% FIRE HYDRANT
9 WATER METER
6 SEWER LATERAL
�j
\` �.`•. .,,.,,,,,� � .6 71,;1. � ---;-
w MACBETH STREET
NOTE DIMENSIONS SHOWN ARE NOTE PLDT PLANS MAY NOT SHOW CURRENT REOORO INFORMATM REFER THE
tion TO' 9WLDINc FACE AND NOT TRtS REPORT FOR DIMENSIONS, EASEMENTS, AND OTHER INFORMATION OF RECORD.
ARC1{RflCTURAI POP—OUTS DRY UTAI ES ARE NOT SHOWN ON THIS PUW.
MSA CONSULTING, INC LE{WAR / CINTIN RANCH
rr eeauro • Cnx a Lm Euzymm JULY 2014
J'ID >W Ums Davu • Rmmw Mamm a CA MM TRACT NO. 32879
7'" CT"` . F,," c16m '� LOT 138 MW MaCBeth street Lor AaEA
LENNAR LA CUNTA, RI1l COL*M, CALFOFHA 16,385 SF
980 MONTECfTO ORTVE
CORONA, CA 92879