BPOL2016-0148A-495 CALLE TAMPICOD Q� VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 11/2/2016
Application Number: BPOL2016-0148Q er:
Property Address: 53389 VIA BELLAGIO Q RDE RESIDENCE
APN: 777160029 D PLAINTA,
VIA BELLAGIO
Application Description: VELARDE RESIDENCE / POOL, SPA & ATURE CA 92253
Property Zoning: NOV 0 8 2016
Application Valuation: $30,000.00
CITY OF LA QUINTA
Applicant: DESIGN AND DEVELOPMENT DEPARTI��RRAN actor,
POOLS AND SPAS INC - ANDT POOLS AND SPAS INC
77564 COUNTRY CLUB DR 77564 COUNTRY CLUB DR
PALM DESERT, CA 92211 PALM DESERT, CA 92211
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C53, C27 License No.: 800680
(D_ r' ^Contractor:
�_
OWNE - ER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the"
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a'
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) 1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
(760)771-2121
Llc. No.: 800680
WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
Df the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: EXEMPT Policy Number:._
I certify that in the performance of the work for which this permit is issued_, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with thossee provisions.
Date: tY V tlo/Applican
WARNING: FAILURE TO SECURE W RKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if'work is
not commenced within 180 days from date of issuance of such permit, or cessation of'
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Dated—a/kignature (Applicant or A
Date: 11/2/2016
i4lication Number: BPOL2016-0148
Owner:
Property Address: 53399 VIA BELLAGIO
VELARDE RESIDENCE
APN: 777160029
53389 VIA BELLAGIO .
Application Description: VELARDE RESIDENCE / POOL, SPA & WATER FEATURE
LA QUINTA, CA 92253
Property Zoning:'
Application Valuation: '$30,000.00
Applicant:
Contractor:
REMBRANDT POOLS AND SPAS INC
REMBRANDT POOLS AND SPAS INC
77564 COUNTRY CLUB DR
77564 COUNTRY CLUB DR
PALM DESERT, CA 92211
PALM DESERT, CA 92211
(760)771-2121
---------------------- ------------------------------------------------------------------------
Llc. No.: 800680
Detail: POOL, SPA, FIRE PIT & WATER FEATURE. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE
WITH MANUFACTURER SPECIFICATIONS. ALARMS AND
BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2013 CALIFORNIA BUILDING
CODE.
FINANCIAL INFORMATION
DESCRIPTION.,.,.,.. ACCOUNT -QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $2.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$25.33
Total Paid for PLUMBING FEES: $38.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DETACHED SPA/WATER FEATURE/OTHER
101-0000-42404
0
$190.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SWIMMING POOL/SPA
101-0000-42404
0
$190.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SWIMMING POOL/SPA PC
101-0000-42600
0
$103.36
Total Paid for POOL / SPA: $483.36
i I U I ALS: 5523.36
Bin #
City of La Qc rota
Buildin; 8t- Safety Division
Permit u � + ' 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
1-00w Building Permit Application and Tracking Sheet
Project Address:
5-3 3 3`1 V i k (?�z (A 1� p Owner's Name: edp,,•(„�—
A. P. Number:
Address: , 5– 3 3 at u 1 w I l 0
Legal Description:
City, ST, Zip: C2 'Al
Contractor: n � (/ k $ ..S
b �/ J S
Telephone: �—
Address:
Project Description:V G
ST,
City, Zip:
— - ... _._
U d-4<.-r-
Te
Telephone: le h
o . 7O
G 1
State Lie. # : ';00 i� j10
City Lie. #;
Arch., Engr., Designer:
Address:
City, ST, Zip:
Telephone:
h one:
Construction Type: Occupancy:eY
:
State Lie.
e circle one < Alter ReaDe
Projecttype
t3P
Name of Contact Person: ,
Sq. Ft.:
#eAdd,n
Stories:
Units:
Telephone # of Contact Person: %iO
S'%
Estimated Value of Project: /Y- 3 0. W
APPLICANT: DO NOT WRITE BELOW THIS LINE
tl
Submittal
Req'd
Rcc'd
TRACYING .
.PERMIT FEES
Plan Sets
Plan Check submitted
'Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Clieck Deposit
Truss Calcs.
Called'Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction '
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for corrections/issue
Electrical
Subcontacfor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'`'. Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
Pub. Wks. Appr
Date of permit issue
School Fees,
..
I
Total Permit Fees
CITY. OF LA QUINTA -CONTRACTOR LIST
JOB ADDRESS 533
.SUB.
n- U
87� J I k In a d 'k CAA PERMIT. NUMBER OWNER VQ-��`� - _ BUILDER
This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response:
sification,.....
:..:::.:............................:....................................
Go.ntcac. for<a>::>:::::::>;:?:::»:::::::::<:.>::<:;:<
:;:>:::>.<:::;>a;> .. :::;:;::..:....::::;:>:>:;:
S a r License
t te..Contracto ..s..
<:•>::<>:>:>:::::<:.:>%'`;:::;:>::<::' :`'surance
W:orkers..Co. m ation:ln
Bu'sin ss.L
Name
Cla Classification
License se Nutuber
ExP. Date
Carrier
meromPanY
PoficYN
Exp.
Lice nse m
Exp.
Date
ABC 8
xxxxxx
' xx x
xa
e. . St to Fund, CaIComP
(Format Varies )
x!xxxx
xxxx1
xx/xx/x x
3e.9.
:EARTIWO K. (C 12)
;.
7U(1�"v nki C�rNS � .
C �j
3v�Y�
j
- I I
31 3
r �
c >�CG
S� G r n! S
Cl-Ua 7
[o
;:.;::.;::..;".
13-1I 3
_
h
c
r -r
/L
0. tko 1C.. l�
C� S'j
��� 63 �
G/ -;G, ( 7S'k
Cel, P SNS .
10 ):�o
f
L�ATH�::P�LASTER:: G -,o
:�.::::...........:::
1 "N
-�u r. P,v G.rr� .
�- s3
0 a"
�► 3 fi
- (31- l 7
S�� k ��s .
U �i
9 a 7.
7 %
.
FINE:::
;SKEET:{METAL..(,.:,43).. ..:...
1': »::
FLQ.Q RI NG:`:(C..., )..:>:'>>
`>
>GLAZIN:G : C :I:7j? >' > #z' <;
i
>>
ANS:ATIOf)I -'--JC2);> `
S E W A GF>D I S F(.C2) >:
`<
"PA'I N:TI N G`{ C'=3 3 )':>>'"'<'><
.:::::.::::::::
ERAMIC::...�4....:(:..::..::.:t
L-A .N,QSCAPING;(G::27)
;
i
t
Sladden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 9Z201 (760) 863.0713 Fax (760) 863-0847
6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
800 L Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778
March 27, 2014 Project No. 544-14075
14-03-113
Mike Jeha Construction
53731 Via Malloria
La Quanta, California 92253
Project: Proposed Custom Residence
53-389 Via Bellagio - Lot 312
The Hideaway
La Quinta, California
Subject: Geotechnical Update
Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated
September 22, 2000; File No. 07117-10, Report No. 00-09-772
Report of Testing and Observation During Rough Grading prepared by ESS dated
August 28, 2002; File No. 07117-11, Report No. 01-07-718
Report of Testing and Observation During Rough Grading prepared by Sladden
Engineering dated October 12, 2003; Project No. 544.2199 Report No. 03-10-647
As requested, we have reviewed the above referenced geotechnical reports as they relate to the
design and construction of the proposed custom residence. The project site is located at 53-389
Via Bellagio within the Hideaway Golf Club development ha the City of La Quinta, California. It
is our understanding that the proposed residence will be a relatively lightweight wood -frame
structure supported by conventional shallow spread footings and concrete slabs on grade.
The subject lot was previously graded during the rough grading of the Hideaway project site and
was subsequently regraded. The rough grading included over -excavation of the native surface
soil along with the placement of engineered fill soil to construct the building pads. The regrading
included processing the surface soil along with minor cuts and fills to construct the individual
building pads to the current configurations.' Some additional over -excavation was performed In
areas where the building envelopes were reconfigured. The most recent site grading is
summarized in the referenced Report of Testing and Observations During Rough Grading
prepared by Sladden Engineering along with the compaction test results.
The referenced reports include recommendations pertaining to the construction of residential
structure foundations. Based upon our review of the referenced reports, it is our opinion that the
structural .values included in the referenced grading report prepared by Sladden Engineering
remain applicable for the design and construction of the proposed residential structure
foundations.
Sladden Engineering
March 27, 2014 -2- Project No. 54414075
14-03-113
Because the lot has been previously rough graded, the remedial grading required `at this time
should be minimal provided that the building falls within the previously established building
envelope. The building area should be cleared of surface vegetation, scarified and moisture
conditioned prior to precise grading. The exposed surface should be compacted to a minimum of
90 percent relative compaction is attained prior to fill placement. Any fill material should be
placed in thin lifts at near optimum moisture content and compacted to at least 90 percent
relative compaction. .
The allowable bearing pressures recommended in the referenced grading report prepared by
Sladden Engineering remain applicable. Conventional shallow spread footings should be
bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent
grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be
at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing
allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf
for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be
utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The
recommended allowable bearing pressures may be increased by one-third for wind and seismic
loading.
Lateral forces may be resisted by friction along the base of the foundations and passive resistance
along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is
recommended for use in design. Passive resistance may be estimated using an equivalent fluid
weight of 300 pcf. - If used in combination with the passive resistance, the frictional resistance
should be reduced by one third to 0.33 times the normal dead load forces.
The bearing soil is non -expansive and falls within the "very low" expansion category in
accordance with 2013 California Building Code (CBC) classification criteria. Slab thickness and
reinforcement should be determined by the structural engineer. We recommend a minimum
floor slab thickness of 4.0 Inches. All slab reinforcement should be supported on concrete chairs
to ensure that reinforcement is placed at slab mid -height.
Slabs with moisture sensitive surfaces should be underlain will, a xhoisture vapor retarder
consisting of a polyvinyl chloride membrane such as 10 -mil Visqueen, or equivalent. All laps
within the membrane should be sealed and at least 2 inches of clean sand should be placed over
the membrane to promote uniform curing of the concrete. To reduce the potential for punctures,
the membrane should be placed on a pad surface that has been graded smooth without any sharp
protrusions. If a smooth surface can not be achieved by grading, consideration should be given to
placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the
membrane.
Based on our field observations and understanding of local geologic conditions, the soil profile
type judged applicable to this site is So, generally described as stiff soil. The following presents
additional coefficients and factors relevant to seismic mitigation for new construction based upon
the 2013 California Building Code (CBC).
Sladden Engineering
March 27, 2014 -3- Project No. 544-14075
14-03-113
The seismic design category for a structure may be determined in accordance with Section 1613
of the 2013 CBC or ASCE7, According to the 2013 CBC, Site Class D may be used to estimate
design seismic Ioading for the proposed structures. The 2013 CBC Seismic Design Parameters are
summarized below.
Risk Category (Table 1.5-1): I/11/II1
Site Class (Table 1613.3.2): D A
Ss (Figure 1613.3.1): 1.500g
S1(Figure 1613.3.1): 0.671g
Fe (Table 1613.3.3(1)):1.0
Fv (Table 1613.5.3(2)):1.5
Sms (Equation 16-37 (Fa X Ssl):1.5008
Sm1 (Equation 16-38 (Fv X S11): 1.006g -
SDS (Equation 16-39 (2/3 X Sms}): 1.000g
SD1(Equation 16-40 (2/3 X Sm1)): 0.671g'
Seismic Design Category: D
In addition, we have sampled the surface soil on the subject lot to determine the soluble sulfate
content as it relates to selecting appropriate concrete mix designs. Testing indicates that the site
soil is generally considered non- corrosive with respect to concrete. The testing indicated soluble
sulfate content of 250 ppm (0.250 percent) that corresponds with the "negligible" exposure
category in accordance with ACI 318-08, Table 3. Based upon this, the use of sulfate resistance
concrete mixes is not required.
If you have questions regarding this letter or the referenced reports, please contact the
undersigned.
Respectfully submitted,
SLADDEN ENGINEERING
Brett L. Ander4��M�
Principal EngiSER/lg
Copies: 4 / Addressee
Sladden Engineering
mm
K
8110 o CMT YMALE:
WATM WAU
,�Z�=,-_o-
wAL
TGH POOL CAPING
MITE SLAB
NLE5STEA SHEER DECENT
;,OL oOPIN6
GK
t TO E1E SELECTED BY INTERIOR
��-•'TAT