Loading...
13-0205 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 13-00000205 79872 DANDELION DR 604-484-007-29 -24197 - REMODEL - RESIDENTIAL LOW DENSITY RESIDENTIAL 250000 (&`�v 4 " , J BUILDING & SAFETY DEPARTMENT J0 BUILDING PERMIT Owner: NGUYEN PAUL N 44750 MONTICELLO AVE LA QUINTA, CA 92253 Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am liceunder provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and To essio Is Code, and my License is in full force and effect. License Class: B C53 C10 cense No.: 836088 t7i 9 Date: 05 NCoa'ntrabctor: ER- ILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: r CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT r' Contractor: 1ST ATRIUM INC P.O. BOX 3882 PALM DESERT, CA 92261 (760)880-6606 Lic. No.: 836088 VOICE .(760) 717-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/08/13 MAY 14 2013 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is' issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0028277008 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should be u act to the workers' compensation provisions of Section 3700 of the Labor Code, I s I �f h it comply with those provisions. (� i\1 F`DateO-5I I T I �3 Applicant: A WARNING: FAILURE TO SECURE WO -t SKCOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE.HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a'result of this application, the.owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for ' ction purposes. Date: C./ 5 / 1411&a ture (Applicant or Agent): Application Number . . . . . 13-00000205 ------ Structure Information FIRE DAMAGE REPAIR & 189SF CONVERSION ----.- Other struct info . . . . . CODE EDITION 2010 ---------------------------------------------------------------------------- # BEDROOMS 1.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee 1164.50 Plan Check Fee 756.93 Issue Date . . . . Valuation . . . . 250000 Expiration Date 11/04/13 Qty Unit Charge Per Extension BASE FEE 639.50 150.00 3.5000 THOU BLDG 100,001-500,000 525.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee 113.15 Plan Check Fee 28.29 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/04/13 Qty, Unit Charge Per Extension BASE FEE 15.00 2570.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 89.95 410.00 .0200 -------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL =------------------------------- 8.20 Permit MECHANICAL Additional desc . Permit Fee . . . . 101.00 .Plan Check Fee 25.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/04/13 Qty Unit Charge Per Extension BASE FEE 15.00 2.00' 9.0000 EA MECH FURNACE <=100K 18.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 76.50 Plan Check Fee 19.13 Issue Date . . . . Valuation . . . . 0 LQPERMIT Application Number . . . . . 13-00000205 Permit . . . . . PLUMBING Expiration Date . . 11/04/13 Qty Unit Charge Per Extension BASE FEE 15.00 8.00 6.0000 EA PLB FIXTURE 48.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments FIRE DAMAGE REPAIR/REMODEL THROUGHOUT ENTIRE DWELLING AND 189SF BEDROOM CONVERSION OF SINGLE CAR GARAGE [ENGINEERED] THIS PERMIT DOES NOT INCLUDE DEMO OF ENTIRE DWELLING, WALLS ARE TO BE REPLACED PER PLAN ONLY. 2010 CALIFORNIA BUILDING CODES. May 8, 2013 8:51:13 AM AORTEGA ----------------------------------------------------------------------------- Other Fees BLDG STDS ADMIN (SB1473) 10.00 ENERGY REVIEW FEE 75.69 STRONG MOTION (SMI) - RES 25.00 Fee summary Charged Permit Fee Total 1455.15 Plan Check Total 829.60 Other Fee Total 110.69 Grand Total 2395.44 LQPERMIT Paid Credited Due .00 .00 1455.15 .00 .00 829.60 .00 .00 110.69 .00 .00 2395.44 440�. Bin # Permit # ­P Project.Addrms:'�; 72- 7 City of La Quanta A. BulkUng 8t Safety Division I . on C,+ P.O. Box 1504,78-495 Calle Tampico 0+,� L.a.Quinta, CA 92253 - -(760) 777-7012 r/+ 0 Building Permit -Application* and Tracking Owner's Name:. 1�7 It A. P. Number. Address:. -79 d'72 Legal Description: c& 'City, ST, Zip: 10 Contractor. /5" AY w tw c-* Telephone: ' Address: 0 go Project Description: City, ST, Zip: _?k64t,j 7)eA_e_4 i'C,1e,(, e-& Telephone: '7(ao "0 6606- "'City -e— CA q State Lic. N: Arch., Engr., Designer. Lit #, Cx if Ce /'j J,--00 14-7 .v v Address: City, ST, Zip: Telephone: 'Telephone: Construction Type: .1(161V Occupancy: State Lic. Nam"fContaci Name of Contact Person: WO&fo "06 Project type (circle one)�' 14ew Add'n. After Repair Demo Stories: -sq. . F' 0 Units: Ft: 2 570 1 Telephone # of Contact Person: Estimated Value of Project; 2 0. APPLICANT: DO NOT WRITE BELOW THIS LINE N I Submittal "Id lkc'd UUCMG PERMITTEES Pian Sets Plan Check Submitted Item Amount' Structural C41cs. Reviewed, ready for corrections Plan Check Deposit. Truss Coles. Called Contact Person Mu Check Balance. Mile 24 CaIcL Plans picked up Construction 'Flood plain plan Plans resubmitted Mechanical Grading plan V Review, ready for correctio Electrical SubcOntattor list Called ContactPerson Plumbing Great Deed Plans picked up S3U H.O.A. Approval Plans resubmitted Grading IN HOUSE;- 3" Re -view; ready for correCtionVISSUC Developer Impact Fee Planning Approval calm Contact Person Y. Pub. Wks. Appr Date of permit Inut School Fees Total Permit Fees —93-15 —7 -3 Date 5/8/13 No. 31632 Owner Paul Nyugen Address 79872 Dandelion Dr City La Quinta Zip Tract # Type Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 or APN # Jurisdiction Permit # No. of Units �t"It Ds��o c° 512 o BERMUDA DUNES Cn RANCHO MIRAGE t7 {� INDIAN WELLS PALM DESERT y LA QUINTA 9,Qr 0O T^ tet[[ rJ YJ 604-484-007 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79872 Dandelion Dr 189 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Garage Conversion At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 189 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Arne Perthus Check No. Bank Name/Recipient of Certificate Telephone Funding Exempt By Dr. Gary Rutherford Superintendent Fee collected /exem d by a Ivrey Payment Recd go.00 --Over/Under. Signature NOTICE: Pursuant to Government Code Section 66020(d)(1) this wil serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the da o hich the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting CCO 3380 La Sierra Ave, Ste 104/110 Riverside, CA 92503 (714) 267-6561 CELL I (951) 934-5444 FAX P�NGIN�P.i�71NG ' RU, . RGV'CV V Date: 5/8/2013 Re: 79872 DANDELION DR, LA QUINTA CA ------------------------------------------------------------- I have reviewed the truss calculations and concluded that they match the proposed roof layout as identified on the framing plans. Respectfully, Ben Ionescu, P.E. BCI Engineering r 1 I BUILDING ENERGY ANALYSIS REPORT PROJECT: Paul Nguyen Residence 79872 Dandelion Drive La Quinta, CA 92253 Project Designer: BCI Architecture and Engineering 3380 La Sierra Avenue, Suite 104/110 Riverside, CA 92503 (714) 267-6561 MAY 14 2013 CTY OF LA QUINTA COMMUNITY DEVELOPMENT Report Prepared by: James H. Terry Terry Engineering 14742 Newport Avenue Tustin, CA 92780 (714) 838-1124 Job Number: 130085 Date: 5/13/2013 MAA I• CITY OSA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION [DATE �J BY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. I . TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 15 18 EnergyPro 5.1 by EnergySoft Job Number: ID: 130085 User Number: 2448 1 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Paul Nguyen Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 5/13/2013 Project Address 79872 Dandeli6n Drw6 La Quiiita California Energy Climate Zone CA Clirnate Zone 15 Total Cond. Floor Area 2, 579 Addition 188 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area SPecial Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-30 2,104 Radiant Barrier Altered Wall Wood Framed R-13 1,336 Ext--R-3.8 Altered Slab Unheated Slab-on-Grade None 2,320 Perim = 199' Existing Door Opaque Door None 33 Altered Roof Wood Framed Attic R-30 475 Radiant Barrier New Wall Wood Framed R-13 207 New Slab Unheated Slab-on-Grade None 188 Perim = 9' New Wall Wood Framed R-13 170 Altered FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (N) 46.7 0.530 0.65 none none Bug Screen Existing Front (S) 8.0 0.350 0.30 2.0 none Bug Screen Existing Left (M 22.0 0.350 0.30 2.0 none Bug Screen Existing Front (S) 15.0 0.350 0.30 none none Bug Screen Altered Rear (N) 50.0 0.350 0.30 none none Bug Screen Altered Rear (N) 80.0 0.350 0.30 none none Bug Screen Altered Left (Vlo 20.0 0.350 0.30 4.0 none Bug Screen Existing Front (S) 25.0 0.350 0.30 2.0 none Bug Screen Existing Front (S) 25.0 0.350 0.30 2.0 none Bug Screen New Right (E) 25.0 0.580 0.65 none none Bug Screen Removed Right (E) 6.0 0.350 0.30 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Altered HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status Undefined System Ducted Ducted Attic, Ceiling Ins, vented 6.0 Altered WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.90 Kitchen Pipe Ins Altered [EnergyPro 5.1 by Energ Soft User Number. 2448 RunCode: 2013-05-13711:39:06 ID: 130085 Page 3 of 18 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Paul Nguyen Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration 1511312013 Date Project Address 79872 Dandelion Drive La Qiiiiita California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,579 Addition 188 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Ar -ea Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-13 28 Altered Slab Unheated Slab -on -Grade None 71 Perim = 0' Altered FENESTRATION U- Exterior Orientation Area( Factor SHGC Overhang Sidefins Shades Status Right (E) 15.0 0.350 0.30 none none Bug Screen Altered Left (W) 15.0 0.350 0.30 none none Bug Screen Altered Right (E) 10.0 0.350 0.30 none none Bug Screen Altered HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Energ Soft User Number: 2448 RunCode: 2013-05-13711:39:06 ID: 130085 Page 4 of 18 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Paul Nguyen Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ Addition/Alteration Date 1511312013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 301.0 ft2 Exposed Slab Floor, 4.000" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 55:0 ft2 Exposed Slab Floor,• 4:000" thick at Master Suite WIC HIGH MASS Design - Verify Thermal Mass: 170.0 ft2 Exposed Slab Floor, 4.000" thick at Master Bath HIGH MASS Design - Verify Thermal Mass: 25.0 ft2 Exposed Slab Floor, 4.000" thick at Left Toilet HIGH MASS Design - Verify Thermal Mass: 40.0 W Exposed Slab Floor, 4.000" thick at Entry HIGH MASS Design - Verify Thermal Mass: 477.0 ft2 Exposed Slab Floor, 4.000" thick at Living Room HIGH MASS Design - Verify Thermal Mass: 15 1. 0 ft2 Exposed Slab Floor, 4.000" thick at Bedroom HIGH MASS Design - Verify Thermal Mass: 148.0 ft2 Exposed Slab Floor, 4.000" thick at Bedroom HIGH MASS Design - Verify Thermal Mass: 188.0 W Exposed Slab Floor, 4.000" thick at (N) Bedroom HIGH MASS Design - Verify Thermal Mass: 49.0 W Exposed Slab Floor, 4.000" thick at Hallway HIGH MASS Design - Verify Thermal Mass: 51.0 ft2 Exposed Slab Floor, 4.000" thick at Bath HIGH MASS Design - Verify Thermal Mass: 46.0 ft2 Exposed Slab Floor, 4.000" thick at Bath HIGH MASS Design - Veiify Thermal Mass: 57.0 ft2 Ezpdsed Slab Floof, 4.000" thidk at Laundry HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed GF -4R form for each of the measures listed below for final to be given. Ene Pro 5.1 by EnemySoft User Number. 2448 Runcode: 2013-05-13T11:39:06 ID: 130085 Pa e 5 of 18 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Paul Nguyen Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ Addition/Alteration I Date 1511312013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 66.0 ft2 Exposed Stab Floor, 4.000" thick at Closet HIGH ASS Pesign - Verify Thermal Mass: 56,0 ft2 Exposed Slab Floor 4:000" thick at Bathroom HIGH MASS Design - Verify Thermal Mass: 22.0 ft2 Exposed Slab Floor, 4.000" thick at Right Toilet HIGH MASS Design - Verify Thermal Mass: 71.0 ft2 Exposed Slab Floor, 4.000" thick at Hallway HIGH MASS Design - Verify Thermal Mass: 59.0 ft2 Exposed Slab Floor, 4.000" thick at Morning Room HIGH MASS Design - Verify Thermal Mass: 260.0 W Exposed Slab Floor, 4.000" thick at Kitchen HIGH MASS Design - Verify Thermal Mass: 287.0 ft2 Exposed Slab Floor, 4.000" thick at (N) Bedroom The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specked in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnerPro 5.1 b Ene Soft User Number. 2448 RunCode: 2013-05-13T11:39:06 ID: 130085 Page 6 of 18 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) F-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Paul Nguyen Residence ❑ Multi Family m Existing+ Addition/Alteration 5/13/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 5.74 4.30 1.43 Space Cooling 67.90 68.18 -0.28 Fans 13.25 15.13 -1.88 Domestic Hot Water 14.02 9.40 4.62 Pumps 0.00 0.00 0.00 Totals 100.91 97.01 3.90 Percent Better Than Standard: 3.9% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 330 73 Fuel Available at Site: Natural Gas Im 543 57 Raised Floor Area: 0 (N) 867 177 Slab on Grade Area: 2,579 (E) 372 31 Average Ceiling Height: 8.0 Roof 2,579 0 Fenestration Average U-Factor: 0.37 TOTAL: 338 Average SHGC: 0.35 Fenestration/CFA Ratio: 13.1% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Terry Engineering 5/132013 Address 14742 Newport Avenue Name James H. Terry 9Signed City/Slate/ZipCity/Slate/Zip Tustin, CA 92780 Phone (714) 838-1124 Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company BCI Architecture and Engineering Address 3380 La Sierra Avenue, Suite 104/110 Name Benjamin Ionescu City/State/Zip Riverside, CA 92503 Phone (714) 267-6561 Signed License It Date EnerqyPro 5.1 by EnemySoft User Number 2448 RunCode: 2013-05-13711:39:06 ID: 130085 Pae 7 of 18 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Paul Nguyen Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1511312013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 301 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1 -A4 Residence Wall 64 0.074 R-13 3.8 None 0 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Wall 144 0.074 R-13 3.8 None 270 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Slab 301 0.730 None 0 180 Existing 4.4.7-A1 Residence Roof 55 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1 -A4 Residence Wall 83 0.074 R-13 3.8 None 270 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Slab 55 0.730 None 0 180 Existing 4.4.7-A 1 Residence Roof 170 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1 -A4 Residence Wall 73 0.074 R-13 3.8 None 90 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Wall 90 0.0741R-13 3.8 None 180 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Wall 65 0.074 R-13 3.8 None 270 90 Altered 4.3.1-A3 (E=4.3.1 -A3) Residence Slab 170 9:730 None 0 180 Existing 4;4;7-A1 Residence Roof 25 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1 -A4 Residence Wall 24 0.074 R-13 3.8 None 270 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Slab 25 0.730 None 0 180 Existin 4.4.7-A1 Residence Roof 40 0.031 R-30 0 15 1 Altered 4.2.1-A20 E=4.2.1 -A4 Residence FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 46.7 0.530 Default 0.65 Default 0 Existing (E)Double Vinyl Door Residence 2 Window 4.0 0.350 NFRC 0.30 NFRC 180 Existing (E)Double Vinyl Fixed Residence 3 Window 4.0 0.350 NFRC 0.30 NFRC 180 Existing (E)Double Vinyl Fixed Residence 4 Window 16.0 0.350 NFRC 0.30 NFRC 270 Existing (E)Double Vinyl Operable Residence 5 Window 6.01 0.350 NFRC 0.30 NFRC 270 Existing (E)Double Vinyl Operable Residence 6 Window 5.0 0.350 NFRC 0.30 NFRC 180 Altered Double Non Metal Operable Residence 7 Existing 0.550 Default 0.67 Default (Rem)Double Vinyl Fixed pre -altered for above 8 Window 20.0 0.350 NFRC 0.30 NFRC 0 Altered Double Non Metal Operable Residence 9 Existing 0.580 Default 0.65 Default (Rem)Double Vinyl Operable pre -altered for above 10 Window 40.0 0.350 NFRC 0.30 NFRC 0 Altered Double Non Metal Door Residence 11 Existing 0.530 Default 0.65 Default (Rem)Double Vinyl Door pre -altered for above 12 Window 10.0 0.350 NFRC 0.30 NFRC 180 Altered Double Non Metal Operable Residence 13 Existing 0.580 Default 0.65 Default (Rem Double Vinyl Operable pre -altered for above 14 Window 20.0 0.350 NFRC 0.30 NFRC 270 Existing (E)Double Vinyl Qperable Residence 15 Window 25.0 0.350 NFRC 0.30 NFRC 180 Existing (E)Double Vinyl Operable Residence 16 Window 25.0 0.350 NFRC 0.30 NFRC 180 New Double Non Metal Operable Residence (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Overhang Left Fin Ri ht Fin Len H t LEA PExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 2.0 2.0 2.0 0.1 4.0 4.0 3 Bug Screen 0.76 2.0 2.0 2.0 0.1 4.0 4.0 4 Bug Screen 0.76 4.0 4.0 2.0 0.1 4.0 4.0 5 Bug Screen 0.76 3.0 2.0 2.0 0.1 4.0 4.0 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0:76 14 Bug Screen 0.76 5.0 4.0 4.0 0.1 4.0 4.0 15 Bug Screen 0.76 0.0 0.0 2.0 0.5 6.0 6.0 16 Bug Screen 0.76 5.0 5.0 2.0 0.5 6.0 6.0 EnergyPro 5.1 by EnergySoft User Number: 2448 RunCode: 2013-05-13711:39:06 10: 130085 Page 8 of 18 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Paul Nguyen Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1511312013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 10 0.074 R-13 3.8 None 180 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Door 33 0.600 None 180 90 Altered 4.5.1-A5 E=4.5.1 -A5 Residence Slab 40 0.730 None 0 180 Existing 4.4.7-A 1 Residence Roof 477 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1 -A4 Residence Wall 100 0.074 R-13 3.8 None 0 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Slab 477 0.730 None 0 180 Existing 4.4.7-A 1 Residence Roof 151 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1 -A4 Residence Wall 17 0.074 R-13 3.8 None 180 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Wall 31 0.074 R-13 3.8 None 270 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Slab 151 0.730 None 0 180 Existing 4.4.7-A1 Residence Roof 148 0.031,R-30 0 0 Altered 4.2.1-A20 (E=4.2.1 -A4) Residence Wall 58 0:074 R-13 3:8 None 180 90 Altered 4:3:1-A3 E=4:3:1 -A3 Residence Wall 114 0.074 R-13 3.8 None 270 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Slab 148 0.730 None 0 180 Existing 4.4.7-A1 Residence Roof 188 0.031 R-30 0 15 1 New 4.2.1-A20 Residence Wall 49 0.102 R-13 i 180 90 1 New 14.3.1-A3 lResidence FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 17 Window 25.0 0.580 Default 0.65 Default 90 Removed (Rem)Double Vinyl Operable Residence 18 Window 6.0 0.350 NFRC 0.30 NFRC 90 New Double Non Metal Operable Residence 19 Window 30.0 0.350 NFRC 0.30 NFRC 0 Altered Double Non Metal Operable Residence 20 Existing 0.580 Default 0.65 Default (Rem)Double Vinyl Operable pre -altered for above 21 Window 15.0 0.350 NFRC 0.30 NFRC 90 Altered Double Non Metal Operable Residence 22 Existing 0.580 Default 0.65 Default (Rem)Double Vinyl Operable pre -altered for above 23 Window 15.0 0.350 NFRC 0.30 NFRC 270 Altered Double Non Metal Operable Residence 24 Existing 0.580 Default 0.65 Default (Rem)Double Vinyl Operable • pre -altered for above 25 Window 40.0 0.350 NFRC 0.30 NFRC 0 Altered Double Non Metal Door Residence 26 Existing 0.530 Default 0.65 Default (Rem)Double Vinyl Door pre -altered for above 27 Window 10.0 0.350 NFRC 0.30 NFRC 90 Altered Double Non Metal Fixed Residence 28 Existing 0.350 NFRC 0.30 NFRC (E)Double Vinyl Operable pre -altered for above (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: . 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Overhang Left Fin Ri ht Fin Len H t LExt FiExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 2448 RunCode: 2013-05-13T11:39:06 ID: 130085 Page 9 of 18 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Paul Nguyen Residence Building Type m Single Family ❑ Multi Family ❑ Addition Alone m Existing+ Addition/Alteration Date 1511312013 OPAQUE SURFACE DETAILS Surface U- Insulation Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments Wall 158 0.102 R-13 0 90 New 4.3.1-A3 Residence Slab 188 0.730 None 0 180 New 4.4,7-A1 Residence Roof 49 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1-A4 Residence Slab 49 0.730 None 0 180 Existing 4.4.7-A1 Residence Roof 51 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1-A4 Residence Slab 51 0.730 None 0 180 Existing 4.4.7-A1 Residence Roof 46 0.031 R-30 0 15 Altered 4.2,1-A20 E=4.2.1-A4 Residence Wall 12 0.102 R-13 0 90 Altered 4.3,1-A3 E=4.3.1-A3 Residence Slab 46 0.730 None 0 180 Existing 4.4,7-A1 Residence Roof 57 0.031.R-30 0 15 Altered 4.2.1-A20 E=4.2.1-A4 Residence Wall 70 0.102 R-13 0 90 Altered 4.3.1-A3 (E=4.3.1-A3) Residence Slab 57 0730 None 0 180 Existin 4.4:7-A1 Residence Roof 66 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1-A4 Residence Wall 88 0.102 R-13 0 90 Altered 4.3.1-A3 E=4.3.1-A3 Residence Slab 1 66 0.730 None 0 180 Existin 4.4.7-A1 Residence Roof 1 56 0.031,R-30 0 15 Altered 4.2.1-A20 E=4.2.1-A4 Residence FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Overhang Len H t LExt RExt Left Fin Right Fin Dist Len H t Dist Len H t EnergyPro 5.1 by EnergySoft User Number: 2448 RunCode: 2013-05-13T11:39:06 ID: 130085 Pae 10 of 18 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Paul Nguyen Residence Building Type m Single Family ❑ Multi Family ❑ Addition Alone m Existing+ Addition/Alteration Date 1511312013 OPAQUE SURFACE DETAILS Surface U- insulation Type Area Factor Cavity Exterior Frame Interior Frame Azm I Tilt Status Joint Appendix 4 Location/Comments Wall 50 0.074 R-13 3.8 None 901 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Slab 56 0.730 None 0 180 Existing 4.4.7-A 1 Residence Roof 22 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1 -A4 Residence Wail 48 0.074 R-13 3.8 None 90 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Wall 28 0.102 R-13 1 0 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Slab 22 0.730 None 0 180 Existing 4.4.7-A 1 Residence Roof 71 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1 -A4 Residence Slab 71 0.730 None 0 180 Altered 4.4.7-A1 E=4.4.7 -A1 Residence Roof 59 0.031 R-30 0 15 Altered 4.2.1-A20 E=4.2.1 -A4 Residence Wall 64 0.074 R-13 3.8 None 0 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Wall 25 0.074.R-13 3.8 None 90 90 Altered 4.3.1-A3 (E=4.3.1 -A3) Residence Wall 25 0:074 R-13 3:8 None 270 90 Altered 4:3:1-A3 E=4:3:1 -A3 Residence Slab 59 0.730 None 0 180 Existing 4.4.7-A1 Residence Roof 260 0.031 R-30 015 Altered 4.2.1-A20 E=4.2.1-64 Residence Wall 14 0.074 R-13 3.8 None 0 90 Altered 4.3.1-A3 E=4.3.1 -A3 Residence Slab 260 0.730 None 1 01 180 1 Existing 4.4.7-A1 Residence FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGCz Azm Status Glazing Type Location/Comments (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Overhanq Len H t LExt RExt Left Fin Dist Len H t Ri ht Fin Dist Len H t EnergyPro 5.1 by EnergySoft User Number.- 2448 RunCode: 2013-05-13T11:39:06 ID: 130085 Pae 11 of 18 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Paul Nguyen Residence Building Type m Single Family ❑ Multi Family ❑ Addition Alone m Existing+ Addition/Alteration Date 1511312013 OPAQUE SURFACE DETAILS Surface U- Insulation Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments Roof 287 0.031 R-30 0 15 New 4.2.1-A20 Residence Wall 92 0.074 R-13 3.8 None 0 90 Altered 4.3.1-A3 E=4.3.1-A3 Residence Wall 145 0.074 R-13 3.8 None 90 90 Altered 4.3.1-A3 E=4.3.1-A3 Residence Slab 1 287 0.730 None 0 180 Existing 4.4.7-A 1 Residence FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H f Wd Overhang Len H t LExt RExt Left Fin Dist Len H t Right Fin Dist Len H t EnergyPro 5.1 by EnergySoft User Number. 2448 RunCode: 2013-05-13711:39:06 ID: 130085 Pae 12 of 18 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Paul Nguyen Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family © Existing+ Addition/Alteration Date 1511312013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Removed Volume Year Built Undefined System Master Suite ­_Altered 301 2,408 2000 Master Suite WIC 55 440 2000 Master Bath 170 1,360 2000 Left Toilet 25 200 2000 Entry 451 320 2000 Living Room 477 3,816 2000 Bedroom 151 1,208 2000 Bedroom 148 1,184 2000 (N) Bedroom 188 1,504 Hallway 49 392 2000 Bath 51 408 2000 Bath 46 368 2000 Laundry 57 456 2000 Closet 66 528 2000 Bathroom 56 448 2000 Totals 1 188 561 2,3351 0 HVAC SYSTEMS -- System S stem Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Undefined System 2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Altered pre -altered for above Central Furnace 80% AFUE Split Air Conditioner 9.7 SEER Setback HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Undefined System Ducted Ducted Attic, Ceiling Ins, vented 6.0 ❑ Altered pre -altered for above Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ ❑ WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Tankless Water Heater 1 Instant Gas Kitchen Pipe Ins 199,000 0 0.90 n/a n/a Altered Standard Gas 50 gal or Le 1 1 Small Gas pre -altered for Above 40,000 50 1 .58 n/a I n/a MULTI=FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 Eu vN a S: System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number. 2448 RunCode: 2013-05-13TH:39:06 ID: 130085 Pae 13 of 18 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Paul Nguyen Residence Building Type D Single Family ❑ Addition Alone ❑ Multi Family © Existing+ Addition/Alteration Date 5/13/2013 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area Existinq Altered Removed Volume Year Built Right Toilet 22 176 2000 Hallway 71 568 2000 Morning Room 59 472 2000 Kitchen260 2,080 2000 (IV) Bedroom 287 2,296 2000 Totals 1881 56 2,335 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC DISTRIBUTION System Name Heating Cooling Duct Ducts Duct Location R -Value Tested? Status WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status MULTI=FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft � 0 v a — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number.' 2448 RunCode: 2013-05-13711:39:06 ID: 130085 Pae 14 of 18 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Paul Nguyen Residence Date 1 5/1312013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF=1 R, CF=1 R=ADD, or CF= 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 a 1 Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. e. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. 150(c): Minimum R-13 insulation in wood -frame wall orequivalent 1.1 -factor. 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. _ 1.56 f.:A_ ir_r_etardin wr_ _is tested,_labeled.-and_installed_accordin toASTM_E1.67_7_95. 2000 when_s .eci.fied_on-th.e_CF=tRF.orm.. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B; Masonry or factory -built fireplaces hay@ a combustion outside air intake; which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i Heath!- sV stern § afe Wi--dd with tMefrnostdts that meet the set6adk fe-iiif6fn-6ints df Sddtion 112(d). §150(j)l A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1506)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1506)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatingsections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 15O(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(6)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.1 by EnergySoft User Number. 2448 Run Code: 2013-05-13711:39:06 ID: 130085 Page 15 of 18 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Paul Nguyen Residence 1511312013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated d6M--er§. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing_ the Whole Building_ Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)l : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a lineevoltage socket or line= voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. XG€PTION; Up to 50 watts for dwelling units less than or equal to 2;500 ft2 or 100 watts for dwelling units larger than 2i500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro5.1 by EnergySoft User Number.' 2448 RunCode: 2013-05-13T11:39:06 /D: 130085 Page 16 of 18 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Paul Nguyen Residence 1511312013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housin and ceilin . §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number. 9446 RunCode: 2013-05-13711:39:06 10:150085 Page 17 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Paul Nguyen Residence Date 5/13/2013 System Name Undefined System Floor Area 2,579 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 2,878 Return Vented Lighting Return Air Ducts Return Fan Ventilation 387 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 68,000 33,304 4,997 835 29,910 Total Output Btuh 136,000 0 Output Btuh/s ft 52.7 2,273 1,725 Cooling System 01 0 Output per System 48,000 15,370 2,007 387 17,906 Total Output Btuh 96,000 0 7,003 0 Total Output (Tons) 8.0 2,273 1,725 Total Output Btuh/s ft 37.2 Total Output s tt/Ton 322.4 53,219 51,267 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Carrier 24ABB348 CU/58STX090-20 Fum 56,945 32,194 136,000 Airflow cfm/s ft 1.24 Airflow cfm/Ton 400.0 Total Adjusted System Output (Adjusted for Peak Design 666ditiens) 1 TIME OF SYSTEM PEAK 56,945 32,194 136,000 Aug 3 PM Jan 1 AM Outside Air % 12.1 % Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 64 OF Outside Air 387 cfm Supply Fan 3,200 cfm 69 OF 64 OF 104 OF Heating Coil _ 104 OF Roots 70 OF I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79!68°F 79/68°F 62/62°F Q' c Outside Air Ar 387 cfm Supply Fan Cooling Coil 3,200 cfm 75/66°F 63 / 62 OF M 65.4% I ROOM 74/66°F I EnergyPro 5.1 by EnergySoft User Number: 2448 RunCode: 2013-05-13T11:39:06 ID: 130085 Page 18 of 18 IN t✓iJGrIN��p�INGr J . 3380 La Sit a Ave, Ste 104/110 Riverside, bAA2503 (714)`267-6561 CELL (05 1) 934-5444 FAX PROJECT: NGUYENRESIDENCE ADDRESS: 798 72 DANDELION DR LA QUINTA, CA DATE: 02-2013 CODE: 2010 CALIFORNIA RESIDENTIAL CODE 1. All wood bearing on concrete or masonry shall be pressure treated Douglas -Fir or Redwood. 2. Structural members shall not be cut nor notched without the approval of the Engineer. 3. Metal anchors, fasteners, and connectors shall be Simpson Strong -Tie connectors. Substitutions must be approved by the Engineer. 4. All structural lumber shall be Douglas Fir -Larch with 19% maximum moisture content. 13FESS/ S. Unless otherwise noted, use the followinglumber grades: �� 10 �� 2x4 suds Constructionor Stud Grade PM1N FS,I 2x6 suds ......No. 2 �co G ro 2x Joists ......No. 2 LU No.r654,182 / 4x 10 beams and smaller ......No. 2 Exp. 4x12 beams and larger ......No. 1 6x beams ......No. 1 sTq�OFCAI-Wp��\P Posts and columns ......No. 1 1. Drypack shall be composed of one part Portland cement to not more than three parts sand. 2. All structural concrete.................................fc = 3000 psi All slab-on-grade/continuous footings/pads ......... fc = 2500 psi All concrete shall reach minimum compressive strength at 28 days. IREINFORCING STEEL 1. All reinforcing shall be A.S.T.M. A-615-40 for #5 bars and smaller. All reinforcing shall be A.S.T.M. A-615-60 for #6 bars and larger. Welded wire fabric to be A.S.T.M..A-185, lap 1-1/2 spaces, 9" min. 2. Splicing of bars shall have lapping of 40 dia. or T-0" min. in all continuous concrete reinforcement (30 dia. for compression). Masonry reinforcement shall have lapping of 40rdia. or 21-0". This is in all cases U.N.O. 3. All reinforcing bars shall be accurately and securely placed before pouring concrete, or grouting masonry. 4. Concrete protection for reinforcement shall be at least equal to the diameter of the bars. Cover shall be as follows, U.N.O.: A. Poured against earth........................3" B. Poured against form below grade........ 2" C. Slabs on grade (from top of slab)........ 1" D. Columns and beams to main bars ........ 2" 1. Fabrication and erection of structural steel shall be in accordance with "Specifications for the Design, Fabrication and "Erection of Structural Steel Buildings", AISC, current edition. Steel to conform to ASTM A36. Round pipe columns shall conform to ASTM A53, Grade B. Square/Rectangular steel tubes ASTM A500, Grade B. 2. All welding shall be performed by certified welders, using the Electric Shielded Arc Process at licensed shops or otherwise approved by the Bldg. Dept. Continuous inspection required for all field welding. 3. All steel exposed to weather shall be hot -dip galvanized after fabrication, or,other a roved weatherproofing method. 14. Where finish is attached to structural steel, provide 1/2"o bolt holes 4'-0" o.c_for .at ac t of nailers. See hit " x 3" CP ma�/rrp Olt ) CITY OF LA QUINTA BUILDING & SAFETY DEPT. h A V 11- M W FFe -90� � FOR CONSTRUCTION DATE M'101? BY c1, - <u/3 CMMUNo o QUINT �F�OP��N T /