Loading...
14810 (BLCK)-'414 " r' - r P.O. BOX 1504 N o • 14 810 Building 78-495 CALLE TAMPICO I, ?Address 45-060 Desert.- .- Hill , Ct. LA OUINTA, CALIFORNIA 92253 Owner Century HOm--s BUILDING: TYPE CONST. OCC. GRP. Mailing Address 153x'3 South *DO St. A.P. Number City Zip ITel. San . BexYic�ic�i:� �. CA 9240 8 Legal Description' Contractor Project Description 751 of 51 high retaining ing wa I l Thland' MaiiG my Address 22235 Pulmar Place I Cit Zip Tel.: grand Terrace . CA92323 (900,) 825-5072 State Lic, City & Classif.. 'C29 3R9400 Lic. # 3598 Sq. Ft. No. No. Dw. Size Stories Units Arch., Engr.; Designer New ❑ Add ❑ Alter ❑ .Repair•❑ Demolition ❑ Address Tel. City Zip State __ i Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section ' 4.7M 7000) t.of Division 3 o the usipog ari P fe §tons Code nd my license is in full fo c and GNATUE TE OWNER -BUILD R ECLARATION Estimated Valuation �* n I hereby affirm that I am exempt from the Contractors License Law for the following $ 9 1,., 62.4. 00 reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a' permit to construct, after, Improve, demolish, or repair any structure; prior to its issuance also • requires the applicant for such permit to rile a signed statement that.he is licensed pursuant to PERMIT AMOUNT _ the provisions of the Contractor's License Law, Chapter 9 (commencing -with Section .7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the a0eged exemption. Any violation of Section 7031.5 by 'any applicant for a permit Plan Chk. Dep. i subjects the applicant to a civil penalty of not more than rive hundred dollars ($500)... ❑ I, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal. do the work, and the structure is not intended or offered for sale. (Sec. 7044; Buisness and COi1St. 0 Professions Code: The Contractor's License Law does not apply to an owner of property who • builds or improves thereon -and who does such work himself or through his own employees, Mech. ! . provided .that such improvements are not intended. or offered for sale. If, .however, the building or Improvement is sold within one year of completion, the. -owner -builder will have the burden Electrical of proving that he did not build or improve for the purpose of sale.). ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing struct the project. (Sec. 7044, Business and .Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and -who contracts for S.M.I, such projects with a contractor(s) pcensed pursuant to the Contractor's License Law.) Grading ❑ I am exempt under Sec B. & P.C.- for this reason Driveway Enc. Date owner Infrastructure WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Workers Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor•Code.) PolieyoQ!' .Company &Copy is filed with the city, ❑ Certified copy is hereby furnished. TOTAL 45.00 CERTIFICATE OF EXEMPTION FROM REMARKS WORKERS' COMPENSATION INSURANCE (This section need *not be completed If the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ anyparson in any manner so as to become subject to the Workers' Compensation Laws of California Date Owner . NOTICE TO APPUCANT: d, after making this Certificate of Exemption. you. should become ZONE: BY: subject to the workers' Compensation provisions of the Labor Code, you must forthwith Setback Distances: ` comply with such provisions or this permit shall be deemed revoked. .. •. Minimum Front Setback from Center Line Rear Setback from Rear Pro WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND Side Street Setback fro L e SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE - HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION,. Side Setback fro a ine DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,' INTEREST; AND ATTORNEYS FEES. FINAL DATE PEC This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this a_ pplication•and state that the above information is correct. Issued by: Date t rmi . I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives this i. f . :of city to enter. the above-., mentioned property for inspection purposes. •Validated by: Signature of applicant Date Mailing Address _ Validation: City, State, Zip CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBIW FEES IST FL. SQ. FT. ® $ UNITS COLL. AREA SLAB GRADE YARD SPKLR SYSTEM 2ND FL. SQ. FT. @ HEATING (ROUGH) STORAGE TANK FORMS MOBILEHOME SVC. BAR SINK POR. SQ. FT. ® DUCT WORK ROCKSTORAGE GAR. SQ. FT. ® POWER OUTLET ROOF DRAINS METER LOOP HEATING (FINAL) DRAINAGE PIPING CAR P. SQ. FT. GAS (FINAL) WALL SQ. FT. DRINKING FOUNTAIN SQ. FT. ® URINAL ESTIMATED CONSTRUCTION VALUATION $ FINAL INSP. WATER PIPING NOTE: Not to be used as property tax valuation V� FLOOR DRAIN MECHANICAL FEES GRADING cu. yd. $ plus x$ WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER FRAMING GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED ROOFING LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4 c SEWAGE DISPOSAL GAR. FIREWALL SO.FT.GAR ® 3/ac HOUSE SEWER LATHING GAS PIPING PERMIT FEE MESH PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCKSTORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APP.IEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM V� WATER SYSTEM GRADING cu. yd. $ plus x$ _$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL Z- I- c9f6D? lot P/l, QlkDe N,t2 00. .- 'hk Ul 7 Bit. A bq in NIAV- C:\WALL\WALLOl.DSNWALL01. LOT 11 TRACT 23935-3 CITY OF LA QUINTA BACKYARD RETAINING WALL SQA EXISTING GARDEN WALL• 7-o 8 x 8 x 18 SLUMP BLOCK FULLY GROUT ALL CELLS --, STEM ,}i4 R%) '[EEL (� #� 18° MIN FOOTIN 4L Ty;� STEEL (( 31 C, Sheet l of 8 #4 0 16" LOT 11 TRACT 23935 BACKYARD RETAINING 1AIA1 Wall Desi ned By: j NOT TO SCALE r - BR N MATE R.C.E. 21884 EXp.9/30/97 Date: February 24,. 1995 • I 1 •to 44 b I CV !c .C:\MALL\WALLOI.DSNWALL01. RETAINING WALL DESIGN. WALL CONFIGURATION: Soil Retention Height (H) 5.00 ft. Cover Over Toe. of Footing (TD) 18 in. Use SOIL Above TOE for RESISTANCE CALCULATIONS ? YES FOOTING CONFIGURATION: HEEL Distance Fixed at Footing Thickness Key Thickness. Key is Located 6 in. LOADING CONDITIONS: 6 in. 12 in. 12 in. from Heel of Footing. Type of Backfill is LEVEL Offset Load (OP) 700.00 plf Offset.Length (OL) = 1.00 £t. Offset.Distance (OD) - 1.50 ft. Offset Ht. Above Footing (OH) 4.00 ft. Sheet 2 of 8 ALLOWABLE STRESSES: (Note: **** Indicates Allowable Stresses EXCEEDED) Special Inspection Required ? .NO Half Allowable Stresses Will Be Used. Steel Grade or Fy (ksi) = 40 ksi (Fs) = 20,000.00 psi Masonry ultimate Compressivo Strength (f'm) = 1,500.00 psi Flexural Stress'(Fb) - 247.50 psi Shear Stress (Fv) - 25.00 psi Bond Stress (u) - 100.00 psi n = E!s/E/m -- 25.8 Concrete Ultimate Compressive Strength (fc)= 2,000.00 psi Flexural Stress (Flc) = 900.00 psi Shear Stress (Fv) -- 49.19 psi Bond Stress (u) 110-350 psi n = E'a/Elc 11.3 Factor of Safety for Sliding (FOSIS) = 1.50 Factor of Safety for Overturning (FOSIO) = 1.50 WALL MATERIAL: Slumpstone Concrete Masonry Units MATERIAL -WEIGHTS: Concrete 16 in. Block 12 in. Block 10 in. Block 8 in. Block 6 in. Block Backfill (SW) = 145.0 pcf 184.0 lbs/sf = 140.0 lbs/sf 116.0 lbs/sf 92.0 lbs/sf 68.0 lbs/sf 120.0 pcf w C:\WALL\WALL01.DSNWALL01. SOIL CONDITIONS: Soil Classification = 4 Sand, Silty Sand, Clayey Sand, Silty Gravel, and Gravel Foundation Pressure 1,500.00 psf Passive Pressure - 150.00 psf/ft Friction coefficient 0.25 Equivalent Fluid Pressure Method 1 1 = Table / Key -In 2 - 'Coulomb' Method 3 = 'Rankine' Method Sheet 3 of 8 Equivalent Fluid Pressure vs. Surface Slope (Per City of L. A. Building Code) Surface Eq. Fluid Slope Press. (pcf) Level 30 5:1 32 4:1 35 3:1. 38 2:1 43 1.5:1 55 1:1 80 Selected Equiv. Fluid Pressure for Design = 30.0 (pcf) OFFSET SURCHARGE LOAD: OR - (0.30 * P * h^2)/(x^2 + h^2)' ORH ;= h--(x*(((x^2 / h^2) -1) * ARCTAN(h/x) - (h/x))) Where: OR = Resultant Force on Wall 30.68 plf ORH Resultant Force Ht. Above Wall 2.49 ft. P Offset Load - 700.00 plf h Offset Ht. Above Footing - 4.00 ft. x = Offset Dist.. from Wall - 1.50 ft. L =Length of .Offset Load - 1.00 ft. or is Divided by 6 for Point Load Condition. E: CAS\ ------------------------------------------------------------------------------=------------------------- FF_R-27-95 MON 0_+8:22 ESGATE ENGINEERING 909 780 1345 P.04 . C;\WALL\WALL0I.DSNWALL01. STEM DESIGN: Soil Depth (H) = 5.00 ft. Block Size (T) - 8.00 in. Eff. Depth (d) = 5.00 in. Bar No. 4 @ 16 in. Spacing.. Sheet 4 of 8 Moment Soil = (EFP*H^3)/6 -- .625:00 + Moment Offset = (OR*ORH) = 76.37 -------..«.."vee'— . TOTAL Moment (M) - 701.3? ft -lbs Force Soil = (EFP*H^2)/2 - 375.00 + Force Offset = (.3'*P*H^2)/(X^2+H^2) = 30.68 TOTAL TOTAL Horizontal Force (P) ---------------- ----------------- _ 405.68 lbs As = PI*(BAR/16)^2*(12/SP) = 0.147 sq. in. Cir = PI*(BAR/8)*(12/SP) = 1.178 in. np = n*(As/(B*d)) = 0.0633 k = (2*np + np^2)^.5 - np 0.298140 j = 1-(k/3) 0.900620 Stresses: Actual Allowable fb =. (12*M/(B*d^2))*(2/(k*j)) = 208.97 psi 247.50 psi. fs = (12*M)/(As*j*d) = 12,691.85 psi 20,000.00 psi fv = P/(B*j*d) = 7.51 pSi 25.00 psi u = P/(Cir*j*d) a 76.47 psi 100.00 psi �i OF CA'VN STEM DESIGN: (Continued) Soil Depth (H) = 0.00 ft. Block Size (T) = 8.00 in. Eff: Depth (d) = 5.00 in. Bar No. 4 @ 16 in. Spacing. Moment Soil = (EFP*H^3)/6 TOTAL Moment (M) Force Soil = (EFP*H^2)/2 TOTAL Horizontal Force (P) .0.00 ----------- ------ 0.00 ft -lbs 0.00 ----------------- 0.00 lbs As = PI*(BAR/16)^2*(12/SP) = 0.147 sq. in. Cir = PI*(BAR/8)*(12/SP) = 1.178 in. np = n*(As/(B*d)) _ 0.0633 k = (2*np + np^2)^.5 - np = 0.298140 j = 1-(k/3) _ 0.900620 Stresses: Actual Allowable fb = (12*M/(B*d^2))*(2/(k*j)) = 0.00 psi 247.50 psi fs = (12*M)/(As*j*d) 0.00 psi 20,000.00 psi fv = P/(B*j*d) _ 0.00 psi 25.00 psi u- = P/(Cir*j*d) = 0.00 psi 100.00 psi. Min. Stem Horiz. Steel= 0.0007 * 512.00 = 0.36 sq. in.= 2 No. 4 Bars I ------------------------------------------------------ --------- --FEB-27-95-,MON 08:23 ESGATE ENGINEERING 909-780 1345 P.06 FOOTING DESIGN: Footing Length (L) - 2 ft. 6 -in. Footing Thickness (T) = 12 in. Toe to Stem (TD) 16 in. Heel to Stem (HD) = 6 in. OVERTURNING MOMENT (OTM): OTM Soil = (EFP*H^3)/6 1,080.00 + OTM Offset = (OR*ORH) = 107.83 ----------------- TOTAL OTM Moment = 1,187.83 ft -lbs Force Soil. = (EFP*H^2)/2 540.00 + Force Offset - (.3*P*H^2)/(X^2+H^2) = 32.11 TOTAL'Horizontal Force (P) = 572.11 lbs RIGHTING MOMENTS (RTM): Item Weight Moment Arm Footing ( 2.50 * 1.00 * 145.00) = 362.50 8 in. Block ( 5.00 * 92.00) -- 460.00 Soil 1 ( 5.00 * 0.50 * 120.0) = 300.00 Offset Load ( 0.50 * 87.50) -- 43.75 Stem Friction ( 572.11 / 3) 190.70- ---------- TOTAL 90.70---------- TOTAL Weight (Rv) = 1,356.95 r = (RTM-OTM)/Rv = ( 2,374.64 - 1,187.83) / Middle Third of Footing is from 0.83 to 1.67 r is in the Middle Third. e = (L/2) -r = SOIL BEARING PRESSURE: * 1.25 = * 1.67 -- * 2.25 * 2.25 * 2.00. _ TOTAL RTM = l Moment 453.13 766.67 675.00 98.44 381.41 ------ - - - - - 2,374.64 1,356.95 = 0.87 ft. 0.3754 ft. Maximum Allowable Soil Pressure = 11500.00 psf (Maximum increased by 20.0% for each foot of footing length over 1 foot to a maximum of 3 times allowable.) Adjusted Maximum Allowable Soil Pressure - 1,950.00 psf Soil Pressure at Toe of Footing = (Rv/L)*(1+((6*e)/L) = 1,031.80-psf Soil Pressure at Heel of Footing = (Rv/L)*(1-((6*e)/L) = 53.77 psf )- MUM' M' A -N F KNbUiZ1 U4 .ctv�� I),,-U� -------------------------------------------------------------------------------------------------------- FEB-27-95 MON 08:23 ESGATE ENGINEERING 909 780 1345 P.07 C :'\WALT.\WALLOI. DSNWALL01. FOOTING STRESS CHECK: TOE of FOOTING: Soil Pressure at Toe of .Stem = Moment at Toe of Stem = Vert. Force at Too of Stem Bar No. 4 @ 16 in. Spacing. As = Pl*(BAR/16)^2*(12/Sp) _ Cir = Pl*(BAR/8)*(12/SP) np = n*(As/(B*d)) k '(2*np + np^2)^.5 - np = stresses: fc = (12*M/(B*d^2))*(2/(k*j)) fs - (12*M)/(As*j*d) w vc = P/(B*J*d) - u = P/(Cir*j*d) 516.18 psf 633.71 ft -lbs 834.65 lbs 0.147 sq. in. 1.178 in. 0.0158 0.1,62891 0.945703 Actual 107.46 psi 6,240.48 psi 8.41 psi 85.62 psi CHECK PLAIN CONCRETE IN HEEL OF FOOTING: Sheet 7 of 8 Allowable 900.00 psi 20,000:00 psi 49.19 psi 304.11 psi Max. Stress in Plain Concrete 1.6*(F'c)^.5 = - 71.55 psi Max. Moment in Plain Concrete = 12*(M*c)/l 1,717.30 ft -lbs Moment at Heel of stem (ft -lbs) No Steel is Required. Actual Maximum 89.19 1,717.30 So SLIDING CHECK: Footing Thickness (T)= 12 in. • Cover over Toe (TC)= 18 in. Passive Res. _ (RES. * (T+TC).^2)/2 = (150.0 * 2.50 ^2)/2 Friction = Rv * Friction = 1,166.25 * 0.250 - TOTAL Sliding Resistance (SR) _ 468.75 lbS 291.56 lbs 760.31 lbs Factor of Safety = SR/P = 760.31-/ 5721.11 1.33 < 1.50 Key is Required. SLIDING CHECK: with 6 in. Key Average Pressure Under Footing = (TOE + HEEL)/2, = 542.78 psf Eq. Soil Depth.= Average/Soil Wt.= 542.78 / 120.-00 = 4.52 ft. Lat. Soil Press. Under Footing = 4.52 * 150.00 = 678.48 psf Key Pass. Soil Res. = (RES.* KEY^2)/2 ( 678.5 * 0.50 ^2)/2 Passive Soil Res. _ (RES. * 14t^2)/2 = (150.0 * 2.50 ^2)/2 Friction - Rv * Friction 1,238.75 * 0.250 . -- TOTAL Sliding Resistance (SR) 84.81 lb 468.75 lb 309.69 lb 863.25 lb Actual Required Factor of Safety = SR/P -- 863.25 / 572.11 = 1.51 1.50 CHECK.STEEL IN KEY: Max Moment on Key = (2/3)*KEY LEN * KEY PAS. RES.= 28.27 ft -lb Actual Maximum Tension in Concrete = (6 * KEY MOMENT) / (B*T^2)'= 1.18 psi 71.55 psi No Key Steel is Required. OVERTURNING CHECK: Actual Required' Factor of Safety = RTM/OTM = 2,374.64 / 1,187.83 = 2.00 1.50 Min. Footing Long. Steel= 0.0020 * 432.00 - 0.86 sq. in.- .5 No. 4 Bars FEB -27-95 MON 08:24 ESGATE ENGINEERING 909 780 1345 P.09 6'0 Ile fr A ie-- e. 0