Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-5220 (SFD)
w PI8 23G4 P.O. Box_l SO4 7814.9,5-CALI:EAMP C LA QUINTA':CALIFOR=N JBUILDING & SAFETY DEPARTMENT ' (760).777-7012 FAX (760) 777-7011 K-9'2 2 5 3 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number Property Address APN: Application description Property Zoning . . . . . Application valuation Owner SHEA LA QUINTA C/O JEFF MCQUEEN 8800 N GAINEY CENTER 350 SCOTTSDALE AZ 85258 047-'000052.20 Date 6/29/04 60340 DESERT ROSE DR 764 -270 -999 -11 -300233 - DWELLING - SINGLE FAMILY DETACHED MEDIUM HIGH DENSITY RES 150034 Contractor _a •,t !. ---------.---------- --.- SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA CA 92253 (760) 777-6005 WCC: NTL UNION INS WC: 7165833 08/01/04 CSLB: 672285 06/30/05 CCC: B -------------------------- Structure Information -------------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 # BEDROOMS 3.00 FIRE SPRINKLERS NO -GARAGE SQ FTG 57:6.00 •PATIO�SQ FTG 177.00 NUMBER OF UNITS 10.00 FIRST FLOOR SQ FTG 1688.00 -------------------------- ----------------------------------- s --------------- Permit . . ... . . BUILDING PERMIT Additional desc Permit Fee 818.00 Plan Check Fee 531.70 Issue Date . . . . Valuation 150034 Qty Unit Charge Per Extension BASE FEE 639.50 51.00 3.5000 THOU BLDG 100,001-500,000 178.50 ---------------------------------------------------------------------------- Permit . . . MECHANICAL Additional desc Permit Fee . . . . 64.00 Plan Check Fee 16.00 Issue Date . . . . Valuation 0 Qty. Unit Charge Per Extension P.O. Box 1504• �� VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT � r Application Number: Applicant: Applicant's Mailing Address: off- .:-aao Date: Architect or Engineer's Address: Lic. No.:. BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals /Code, and my Lice s in full force and effect. icense Classy A Q e—ricenns}e-�No. u ,--Date—'I a u 1 Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): (--) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044. Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I a d unit maintai workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is is; orke ' compensation innce ca _ I certify that, in the performance of the work for which thFs permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree t I. if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall (/fo hwith comply with those provisio S. /Date � I Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY 1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is I agree to comply with all city and county ordinances and state laws relating to building construction, anj hereby authorize representatives of this county to a ter upon )a6 property for inspection purposes. ate IYO-1 l ianature (Applicant.or Agen V ,l C Page 2 Application Number 04-00005220 Date 6/29/04 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 1.00 6.5000 EA' MECH VENT FAN 6.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---=--------------------------------------------------------=--------------- Permit . . ... . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . .85.60 Plan Check Fee . 21.40 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 1688.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 59.08 576.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 11.52 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 128.25 Plan Check Fee '32.06 Issue Date . . . Valuation. 0 Qty Unit Charge Per Extension BASE FEE 15.00 10.00 6.0000 EA PLB FIXTURE 60.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB.WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Permit . . . . . . GRADING PERMIT Additional desc Permit Fee . . . 15.00 Plan Check Fee,. .00 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ------------------------------- Special Notes and Comments --------------------------------------------- SFD -.LOT Plan 4520C 1688 SF with Box >w I 0 Page 3 Application Number . . . . . 0.4-00005220 Date 6/29/04 ---------------------------------------------------------------------------- Special Notes and Comments Bay @ Master (26sf) & 4' Ext Garage (88sf) . ---------------------------------------------------------------------------- Other Fees . . . . . . ... . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 53.17 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 ` DIF•LIBRARIES - RES 225.00 DIF PARK MAINT FAC --RES 5.00 DIF PARKS/REC RES 502."00 STRONG MOTION (SMI) - RES 15.00 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------- - ----- Charged ---------- Paid .,Credited Due Permit Fee Total 1110.85 ---------- ---------- ---------- .00 .00 1110.85 Plan Check Total 601.16 .00 .00 601.16 Other Fee Total 2473.17 .00 .00 2473.17 Grand Total 4185.18 .00 .00 4185.18 0 0/18%005 08:35 17603401819 7 is INSULATION CERTIFICATE This is I:o certify that insulation has been installed in conformance,with the current energy regulai::)n, California Administrative Code, Title 24, State of California, In the building at 60.340 DESERT ROSE DRIVE, I'LOT,301 1, PHASE 7B, LA QUINTA: CA CEI LI l', GS: TYPE: 13LOW MANUFACTURER: Certainteed THICKNESS: R-38 WALL! is TYPE: 13LOW MANUFACTURER: Certainfeed THICKNESS: R-13 GENEI:IAL CONTRACTOR: SHEA HOMES LICENSE -# BY: TITLE: PARACION SCHMID BUILDING PRODUCTS" A MASCO Company ' LIGENSE#2211517 4 BY: TITLE: ACCOUNT REPRESENTIVE ,DATE: INSULATION CERTIFICATE �n 'i the C!Lirre�lw �rgy This is rtiN, that insulation has been installed in conformance with regulatit in, Ca •irnia Administrative Code, Title 24, State of California, int-blGildinq located CEILIN(:iS: TYPE: 1: iLOW MAUNFACT ertainteed THICKNESS: R-38 WALL TYPE: BATTS MAUNFACTURER: Certaiertantee THICKNESS: R-13 -i GENER '�_L -CONTRACTOR: LICENSE TITLE: ITLE: PARA1:;ON SCHMID BUILDING PRODUCTS A MASCO Company LICENS�2211517 BY: TITLE: ACCOUNT REPRESENTIVE DATE' PAGE 11/37 Installation Certificate; Residential CF-6R Site Address PERMIT # - `- _60=340 .Desert Rose Drive; 1. BUILDER INFORMATION SUBDIVISION: Trilogy (o), La Quinta Shea Homes - Trilogy - .LaQuinta CITY: La Quinta 81260 Ave. 62 COUNTY: Riverside La Quinta, CA 92253 INSTALLING CONTRACTOR: WEST PAC AIR CONDITIONING 2. PROTECT INFORMATION DISTRIBUTION DUCTOR PIPING R- TYPE VALUE Flexible Ductwork Flexible Ductwork in Attic and Will have a R-Value Between Floors of 4.2 or Better I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment , installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition, Ihave verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings. ' 3. HEATING INFORMATION UATING MANUFACT HEATING UNIT ACTUAL EFF. HEATING EQUIP HEATING EQUIP. MAKE MODEL # AFUE CAPACITY LOAD Furnace Lennox G40UH48B-090X 80% 88000 4. COOLING INFORMATION COOLING MANUFACT COMPRESSOR ACTUAL EFF.. COOLING EQUIP COOLING EQUIP. MAKE MODEL # SEER CAPACITY LOAD A/C Lennox 13ACC-048 12 The building design heat loss and design heat gain rate have been determined using a method specified in Section 150(h) of. the Energy Efficiency Standards, and are two of the criteria used for equipment sizing and selection. 6.THERMOSTATIC EiPANSION VALVE (TXV); Thermostatic Expansion Valvc (or Commision approved equivalent) is installed and access is provided for inspection. ' Yes ❑ No ❑ N/A ( _ 6. SUBMITTED BY DATE: D5 Signature Installing HVAC Contractor JCM Inspections r 39725 Garand Lane Suite F _ Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 in INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: f p_11„0 Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA �✓ IBC Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips 5%foo psi to 33.04 kips/33,000 lbs Calibration Date: Machine #Z0 _c Phas-elb Lot# 30 11 Product., Plan %} G,o 3qo C�p�4 t ;) �, vz . , We er: ,n� Unresolved Items: ® None See Below Description of Work Inspected: Specified Lot # Location Tendons Elongation (in) Actual Elongation (in) � 0 Cor , t va'►1+� n`7 /o o�- cc.i : o ` l rlof'Ia., i a ,'1— or�-•- b �.»y Got q Q r✓�rj n\� �r �et i�! Z CA4. 3 1r,�at-(�c� I � W•�„dt7�1—S•�• ' I ran, �• lioc� �, e+�"• -�" L' -i' � S-!'-� I � G Orr. no- I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Ja�lc C. Millin ICC Ce if Miron No:0842216-89 Dl C✓ , Contra o step se ye: Copy 1 J )os Copy 2 Project Superintendent Copy 3 Gove ing Agency Page ofM Inspect JCM Inspections r 39725.Garand Lane Suite F ` Palm Desert, CA(92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 I,1' ST E C T I O N S REINFORCED CONCRETE INSPECTION REPORT. Date: ,p Project Name: ' ',k, it i +4 Project No: 1 Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: []Title 24 AWS r�] UBC Other: 81-260 Avenue 62 It S La Quinta, CA File # 0 D 1.1 7APp#, F-1 D 1.4 Client: Sub -Contractor: Shea La Quinta, LLC DCCCC Other General Contractor: Architect: Structural Engineer: i Shea Homes ° V` `a" Bassenian Lagoni % . Bonn & Assoc,lnc/Suncoast Post Tension LP Slump (inches): Supplier: Weather: Time Sampled: Mix Design: suf)n t Time In Mixer (min.): Specified Strength (PSI): Unresoly Items: Water Added @ Jobsite (gals.): Addmixture: None Concrete Temperature (F): Truck #: Ticket:#: Ambient Air Temperature (F):Field ID Marking: . 4 ❑'See Below Location of Sample: IN No Samples Taken Description of Work Inspected: Q h Q e.`� �O 3� p `�c)( a $ I r rn 0 Y l n i C.4]�]A •- v� o + ' n c e. `�1..., r -r1orCrto�C �CQt�.S uta\�i` �N�l`�Qv.� Se,�� ul t(i \• (vSf7,lA xq yrk,,nz. D cn\7 3 It3 �� ' �� GX��<►�,� i� gcr,r�s lg,� fJ)�T�p',`c� �Cliot• S�IG1� Scvc,n to 00 Q�� o n5 �( � , V0?S`oin S ra�, ^', d .J iaj S D�(Inc �a��yr .�� -k ( \W1 (�� \ f1©��:Qki''� E' •� ��-'( � ^oT�!'>c�S `�r Gl�l�\ �r1.icV ol�,c�r �feC�.T+L..0�3 i�C'^^'SFFSQ.. �C', �"i�� f �s 0,� nQ 0V1 - A , 0A L ��. arG Q C �( CnS� nil 'Er o W , na t7C? AT 4c (1 (�1 ` p YY le' Jt c � ScV,,e _ _, Oe t b G'. `SCS G�\\^4� i\er., sic Gi F ��bC((C��),-, . TzV%k �. wcr e Secucc 2-Z I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications -applicable building laws. Final report is . ed at project completion. Inspector: Jack Millin . ICC Cert''►►�`tcI{+� tion No0842216-80 QJ Contractor's IRepre tive: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Gij\ erning Agency Page _L of JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT. Date: 9_a _o Project Name: t Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: Title 24 AWS Q UBC Other: 81-260 Avenue 62 La Quinta, CA File # D 1.1 App# E] D 1.4 Client: Sub -Contractor: Shea La Quinta, LLC DCCCC E] Other General Contractor: i Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP ' Slump (Inches): Supplier: Weather: Time Sampled: ip M Mix Design: Time in Mixer (min.): f� ® Specified Strength (PSI): �Fya VA vn Unresolved ems: Water Added @ Jobsite (gals.): Addmixture: qrJ7- None Concrete Temperature (F): Truck #: 3d' Ticket #: Ambient Air Temperature (F): .� I Field ID Marking: _ a See Below Location of Sample: ,,.. ,,, : A „ .,,. No Samples Taken Description of Work Inspecte %L3Zj „, "e Gn SAO r l! r n c AV cI �� � a C1 dpi . C r n � •t 4.�i rt M � Q Q- env tl �, I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications -applicable building laws. Final report issued at project completion. Inspector: Jacky .Millin ICC Certificatio 842216-80 Contract isRepresenlive: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 ov r ing Agency Page _�of M JCM Inspections .11 T r!M I I 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT. Date: J-30-17A Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA []Title 24 AWS QUBC Other: File # f -I D 1.1 App# E] D 1.4 [] Other Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP • Slump (Inches): Supplier: Time Sampled: Mix Design: Time In Mixer (min.): Specified Strength (PSI): Water Added @ Jobsite (gals.): Addmixture: Concrete Temperature (F): Truck #: Ticket #: Ambient Air Temperature (F): Field ID Marking: Weather: Unresolved I ms: ® None See Below Location of Sample: Co r r- C c_ cAk + �m�. n I u c ', n n t� oa ?1 No Samples Taken Description of Work Inspected r,,j.Q' "�3$ Lo # 3o j Y, orkk �)l c Sap c-. 1 +�Q•+ cr�toc.�G Crl'n •c C C_n <1 l,,}'r+`CGr1o�� t rtnr C—+�C� &C7 0. ` lc'� Oft `` ��o t acl'V— ovf o`(a X13" s C►+^ lb -M .'1 it 1M V,�� ` • p < v��1',, u S�.�O � O ns n \ `I � 2 �uz. t Orx <<`- C/ , + . I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack Millin(( ICC C/ertific doM001 842216-80 Contra or's l3epr sen ire:: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Goveming Agency Page _�__ of _ JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-346-5554 - Fax: 760-772-3895 INSPECTIONS COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 11/14/04 Project: Trilogy @ La Quinta - Shea Homes 81-260 Avenue 62 La Quinta, CA 92274 Project No: 02-1109 Set ID Structure Age of Test Compression Strength JCM ip Location Date Cast Cylinder ID (days) (psi) Set A Phase 7B - Lot # 3011 Slab on Grade 9-29-04 Concrete 273-362 Great Room Required psi: 4000 7799 7 4080 �0 ®�5�/ �S 7800 28 6010 i 7801 28 600 n , \ CERTIFIED: Page 1 of 1 ,i Wnspections supplies the service of compression strength test results only. Per ASTMC39