Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-1398 (BLCK)
7 . 14 4VQw P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number Property Address . . . . APN: Application description Property Zoning . . . . . Application valuation . . BUILDING PERMIT BUILDING &. SAFETY DEPARTMENT (760).777-7012 FAX (760) 77777011 INSPECTION REQUESTS (760) 777-7153 �05l000013'98� Date 4/14/05 81112 DESERT SAGE CT 764-270-999-152-300234- WALL/FENCE MEDIUM HIGH DENSITY RES 4500 Owner Contractor SHEA LA QUINTA SHEA HOMES, INC. C/O JEFF MCQUEEN 81260 AVENUE 62 8800 N GAINEY CENTER 350 LA QUINTA CA 92253 SCOTTSDALE AZ 85258 (760) 777-6005 WCC: NTL UNION INS WC: 6436568 08/01/05 CSLB: .672285 06/30/05 CCC: B ---------------------------------------------------------------------------- Permit . . . . . . WALL/FENCE PERMIT Additional desc Permit Fee . . . . 72.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 4500 Qty Unit Charge Per Extension BASE FEE_ 45.00 3.00 9.0000 THOU BLDG <,2,001-25,000 27.00 ----------------------------- 7 ---------------------------------------------- .Special Notes and Comments 180 L.F. 6' GARDEN WALL, ORCO SYSTEM Fee summary Charged Paid Credited- Due - -------------------------------------------------------- Permit Fee Total 72.00 .00 .00 72.00 Plan Check Total .00 .00 .00 .00 Grand Total 72.00 .00 .00 72.00 t- Q � MAY 19 2005 CITY OF LA QUINTA FINANCE DEPT. P.O. BOX 1504�� VOICE (760) 777-7012 T-Vf. 78-495 CALLS TAMPICOFAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: O 5 - 13'q 8' Date: 5.16-05- Applicant: •/8'05 Applicant: Applicant's Mailing Address: Architect or Engineer: Architect or Engineer's Address: N IA Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License ' in full force and effect. �.LR� A n Q C' License Class ense No. 2285 /� Date 07-bntracto, .�il aP V,S OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property. am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. . BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is //'suer.. �M_ y;� rs',t pmpensation in su a carrier an employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. vs WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY 1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name /� Lender's Address f K APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to. and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby , authorize representatives of this county to ente pon the above-mentione rope y for inspection purposes. 1 Date vS- Signature (Applicant or Agent): Ca10ERTS Certified Rating October, 7 2005 12 This Compliance rating is for the home located at: Desert Sage Court Laa QuDesert CA, 92253 Certificate Number: CC3- 1798350876 Date Inspected: - ' October, 4 R Value 2005 Ca10ERTS Rater: William Orientation Henson CC20.04076 HERS Analyst- N/A Builder/Developer: Shea Homes, Inc. Trilogy @ P Project: La Quinta Plan Name: 4520 Lot Number: 152 eh // ` Sane Cr Specifics about this home: General Information Conditioned Floor Area: 1650 Square Feet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Number of Stories: 1 Keating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 HVAC Air Distribution Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 Air Infiltration Blower Door Target: 96.0 Water Heating System Proposed TY I Size J Fuel I EF Distribution Water Heating S stem Actual TY I Size I Fuel I EF Distribution Building Envelope Surface Area Proposed Actual R Value U I Factor R Value U I Factor Windows FX TESTED . (PAGE 1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211. . PHONE: 760-772-2954. y CERTIFYING SIGNATURE DATE Proposed .1 Actual U U Orientation Area SHGC Value J§HGC Value FX TESTED . (PAGE 1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211. . PHONE: 760-772-2954. y CERTIFYING SIGNATURE DATE Testing Results Main System HVAC System Tested Duct Leakage: IYes - Passed Tested Leakage Flow in CFM: 80 00efm/ton x number of tons: 1600 Leakage Percentage (100 x Test Leakage/Fan Flow) .0 Tested TXV: Yes -Passed Thermostatic Expansion Valve is installed and Access is provided for inspection. Tested Duct Design Compliance: N/A Tested Duct in Conditioned Space: N/A Tested Reduced Duct Surface N/A Area: Tested Infiltration Reduction N/A Credit: The energy efficiency rating of this home is determined. using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for atypical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features fisted have been verified and approved by the Ca10ERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CaICERTS - Customer Service P.O. Box 6600, Folsom, CA 95763. (PAGE 2 OF PHASE // Z LOT z ` Ca10ERTS Certified Rating Area October, 7 2005 This Compliance rating is for the home located at: La Q Desert Sage Court La Quinta CA, 92253 Certificate Number: 17981798 350882 U Date Inspected: October, 4 2005 ` CalCERTS Rater:. William Henson HERS Analyst: CC2004076; N/A' Builder/Developer: Shea ���.,�'` :. .�z Homes, Inc.# Trilogy @ Project: La Quinta Plan Name: Casita Lot Number: 152 PM 116 Specifics about this home: General Information Conditioned Floor Area: 400 Square Feet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Number of Stories: 1 Heating and. Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 HVAC Air Distribution Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 Air Infiltration , Blower Door Target: 48.0 Water Heating S stem Proposed F_QTY I Size Fuel I EF Distribution Water Heatin S stem Actual TY Size I Fuel I EF Distribution Building Envelope Surface Area Proposed Actual RU Value Factor R Value U I Factor Windaws FX TESTED (PAGE 1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211 PHONE: 760-772-2954 CERTIFYING SIGNATURE'DATIE Proposed Actual U I U Orientation Area SHGC Value SHGC I Value FX TESTED (PAGE 1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211 PHONE: 760-772-2954 CERTIFYING SIGNATURE'DATIE r Te.stinQ Results Main System HVAC System Tested Duct Leakage: Iyes - Passed Tested Leakage Flow in CFM: 30 00cfm/ton x number of tons: 800 Leakage Percentage (100 x Test Leakage/Fan Flow) .8 k Tested TXV: Yes -Passed Thermostatic Expansion Valve is installed and Access is provided for inspection. Tested Duct Design Compliance: N/A Tested Duct in Conditioned Space: N/A Tested Reduced Duct Surface N/A Area: Tested Infiltration Reduction N/A Credit: The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the Ca10ERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CaICERTS - Customer Service P.O. Box 6600, Folsom, CA 95763. s (PAGE 2 OF 2) PHASE ( I A LOT��Z CctS( JCM Inspections 725 Garand Lane Suite F Palm Desert, CA 92211 To, INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA �✓ IBC Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Slump (inches): Supplier: Superior Time Sampled: ','p A r- Mix Design: D83625P Time in Mixer (min.): �S Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): Addmixture: POZZ 322N Concrete Temperature (F): Truck #: 4W Ticket #I. Ambient Air Temperature (F): Field ID Marking: Set A - 4 cylinders Weather: Unresolved Items: ®-None ❑ See Below Location of Sample: St t*� ©n V ( C, �lC �5 r C�V o Orn ❑ No Samples Taken Description of Work Inspected: Phase �j Lot# Product �. Plan L45 ao 8�- �a. flesrSQQ� ta� Co------------ 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed asper these details and as noted on S -3 —1 S 3- y S-3- a� j ` , t� �'� , �9 G G a e,� (�� Also, typical details 2, 3/SD-1 and Notes on SNA apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx 10= A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. C�-ai roJ 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx `q Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: J ck C. Millin +(ICC Cte(rtific do ryNo: 0842216-80 Contracttooes.Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page —4of • ,. �,,. ..,, -fit JCM Inspections 39725 Garand Lane Suite.F Palm Desert, "CA 922"11`x;, INSPECTIONS Phone: 760-345-5554 = Fax: 7609772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: ��o�c�-• C) Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: Q✓ IBC 81-260 Avenue 62 La Quinta, CA Title 24 Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning Other: General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Weather: Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons �v 'N A Lk Unreso`I ed Items: Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips psi to 33.04 kips/33,000 lbs one ❑ See Below Calibration Date: Machine #3%s 16 _tea Phas Lot# �.Produc� Planl4 `1 ��, �M� Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 11 h/SN2. - _a_ Yes No (11 A— .31� l � Z' El W Z ❑ o (� V� n � h .r, .ee ., V`}fie x�� •� •1r t tai '.'-" LJ ❑ (\�_ 1 `n?.�)'` H ❑ P1111 YLI [Er El I, ED' ❑ Mr,V _ 24 h 3 ©' ❑ 2 El C'n , . A -,3 yW 0' ❑ \\ 3 [Er El o ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability] have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued a`t project completion. Inspector:'J ck C. Millin ICC Certificati In N :08•°42216-89 Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page __J of I • JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 9/25/05 Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 81-260 Avenue 62 La Quinta, CA 92274 Set ID Structure Age of Test Compression Strength JCM ID Location Date Cast Cylinder ID (days) (psi) Set A Phase 11 B - Lot # 4152 Slab on Grade 273-546 Master Bedroom Page 1 of 1 6-17-05 Concrete Required psi: 4000 433 7 3310 434 28 4780 435 28 4820 CERTIFIED: JCM Inspections supplies the service of compression strength test results only. Per ASTMC39 10/06/2003 16:12 FAX PARAGONPSCHIMID IA 002/012 INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code. Title 24, State of California, in the building at 81-112 DESERT SAGE CT, LOT 4152, LA QUINTA, CA CEILINGS: TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-38 WALLS: TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-13 GENERAL CONTRACTOR: SHEA HOMES LICENSE # BY: TITLE: PARAG N SCHMID BUI tNG PRODUCTS A MASCO Company LICENSE # 221517 6Y: l TITLE: ACCOUNT REPRESENTIVE DATE: