05-1403 (BLCK)BUILDING & SAFETY DEPARTMENT P.O. Box 1504 (760),777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number . . . ... Date 4/14/05 Property Address . . . . . 81153 DESERT SAGE CT APN: 764-270-999-146 -300234- Application description WALL/FENCE Property Zoning . . . . . . . MEDIUM HIGH DENSITY RES Application val„ar;nn 'IR7S Owner SHEA LA QUINTA C/O JEFF MCQUEEN 8800 N GAINEY CENTER 350 SCOTTSDALE AZ 85258 ,Contractor ------------------ SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA CA 92253 (760) 777-6005 WCC: NTL UNION INS WC: 6436568 08/01/05 CSLB: 672285 06/30/05 CCC: B ---------------------------------------------------------------------------- Permit . . . . . . WALL/FENCE PERMIT Additional desc Permit Fee . . . . 63.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 3875 Qty Unit Charge Per Extension .BASE FEE _ 45.00 2.00 9.0000 THOU BLDG 2;00.1-25,000 18.00 ---------------------------------------------- 7 ----------------------------- Special Notes and Comments 155 L.F..6' GARDEN WALL, ORCO SYSTEM Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 63.00 .00 .00 63.00 Plan Check Total .00 .00 .00 .00 Grand Total 63.00 .00 .00 63.00 D Q � MAY 1.9 2005 CITV OF L1L OUINTA FINANCE DEPT. P.O. BOX 1504 • ����� VOICE (760) 777-7012 78-495 CALLS TAMPICo FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: U.5 " j o,-' I . Date: 5. 1 $ • O S - Applicant: Applicant's Mailing Address: Architect or Engineer: Architect or Engineer's Address: A) 1A Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals C e, and my License i full force and effect. icense Class n cense No. U7.22915 / Date Il �/ ntractor ✓IIJCM /v/ "`�� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving tha* he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. . BA P.C. for this reason Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance ``,, of the work for which this permit is issued. �1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is �/ issued. 4, worker6' co ensation m ce carrier ndp� �]�!m e' �efrier /►/�f• 1 Q7'1 I �p olicy Number t —f V!, (� _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, it I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ate 5 d S Applita�nt SA QL 7 71te � WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFLL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name //�� Lender's Address A APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, of cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to -building construction, and hereby authorize representatives of this county to enter upon the above-mentioned prDIDenty for inspection purposes. ate 6ture (Applicant or Agent): CaICERTS Certified Rating Area October, 13 2005 This Compliance rating is for the home located at: 81153 Desert Sage Court R Value U Factor La Quinta CA, 92253 Certificate Number: CC3- 1798350966 Date Inspected: October, 11 2005 CaICERTS Rater: William Henson CC2004076: E HERS Analyst: N/A. Builder/Developer: Shea Homes, Inc.; r� Project: Trilogy @ La Quinta Plan Name: 4210 Lot Number: 146 Ph -1115 �_ -. �/- /.�3 /%Se`s S��e Cr`• Specifics about this home: General Information Conditioned Floor Area: 1500 Square Feet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Number of Stories: 1 Heating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 HVAC Air Distribution Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 Air Infiltration Blower Door Target: 96.0 Water Heatin S stem Pro osed TY Size I Fuel I EF I Distribution Water Hean S stem Actual TY I Size I Fuel I EF Distribution Buildinp, Envelone Surface Area Proosed Actual R U Value Factor R Value U Factor Windows =X TESTED (PAGE1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211 PHONE: 760-772-2964 CERTIFYING SIGNATURE DATE Proposed Actual SHGC U Value SHGC I U Value Orientation Area =X TESTED (PAGE1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211 PHONE: 760-772-2964 CERTIFYING SIGNATURE DATE i Testin Results Main System HVAC System Tested Duct Leakage: IYes - Passed Tested Leakage Flow in CFM: 62 00cfm/ton x number of tons: 1600 Leakage Percentage (100 x Test Leakage/Fan Flow) .9 Tested TXV: I Yes'- Passed Thermostatic Expansion Valve is installed and Access is provided for inspection. Tested Duct Design Compliance: N/A Tested Duct in Conditioned Space: N/A Tested Reduced Duct Surface N/A Area: Tested Infiltration Reduction N/A Credit: I The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for atypical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the Ca10ERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CACERTS - Customer Service P.O. Box 6600, Folsom, CA 95763. (PAGE 2 OF 2) PHASE /I JS LOT / / w�. h CaICERTS Certified Rating October, 13 2005 This Compliance rating is for the home located at: 81153 Desert Sage Court La Quinta CA, 92253 Certificate Number: CC3- Proposed 1798350967 Date Inspected: October, 11 U I Factor 2005 Ca10ERTS Rater: William Henson SHGC CC2004076 HERS Analyst: N/A Builder/Developer: Shea Homes, Inc. Project: Trilogy @ La Quinta Plan Name: Casita Lot Number: 146 - ph l I Specifics about this home: General Information Building Envelope Conditioned Floor Area: 400 Square Feet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Number of Stories: 1 Heating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 HVAC Air Distribution Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 Air Infiltration Blower Door Target: 48.0 Water Hea n S stem Pro osed TY I Size Fuel I EF Distribution Water Hean S stem Actual TY I Size I Fuel I EF Distribution " Surface . Area Proposed I Actual R U Value Factor JR Value U I Factor Windows TESTED (PAGE 1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211 PHONE: 760-772-2954 CERTIFYING SIGNATURE DATE Proposed Actual U U Orientation Area SHGC I Value SHGC I Value TESTED (PAGE 1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211 PHONE: 760-772-2954 CERTIFYING SIGNATURE DATE '3 ., Testin Results Main System HVAC System Tested Duct Leakage: Iyes - Passed Tested Leakage Flow in CFM: 40 00cfm/ton x number of tons: 800 Leakage Percentage (100 x Test Leakage/Fan Flow) 5.0 Tested TXV: Yes -Passed Thermostatic Expansion Valve is installed and Access is provided for inspection. Tested Duct Design Compliance: N/A Tested Duct in Conditioned Space: N/A Tested Reduced Duct Surface N/A rea• Tested Infiltration Reduction N/A Credit: The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the Ca10ERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact CaICERTS - Customer Service P.O. Box 6600, Folsom, CA 95763. r s (PAGE 2 OF 2) PHASE I/ g L ` LOT(Th- t- JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: Z IBC 81-260 Avenue 62 La Quinta, CA Title 24 Client: Sub -Contractor: Shea La Quinta, LLC DCCCC Other: General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc, I nc/Suncoast Post Tension LP Slump (inches): ( Supplier: Superior Weather: Time Sampled: ei Mix Design: D83625P Time in Mixer (min.): fl �-- Specified Strength (PSI): 4000 Unresolved Items: Water Added @ Jobsite (gals.):,,).", Addmixture: POZZ 322N Concrete Temperature (F): Truck #: Ticket #--, ® None Ambient Air Temperature (F): t> Field ID Marking: Set A - 4 cylinders See Below Location of Sample: cj N 1�1 t ❑ No Samples Taken Description of Work Inspected: Phase 1 Lott'## Product.Z Plan 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed as per these details and as noted on _ , .. L( Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx 916 A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICC CertificaNo: 0842216-80 Contrac/toes Reeppr`e�senta'rti�ve- c Copy 1 JCM Inspe�s Copy 2 Project Superintendent Copy 3 Governing Agency Page of 4— JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date`_ t. _OZ -- Project Name: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA Z✓ IBC Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning General Contractor: Architect: Shea Homes Bassenian Lagoni Structural Engineer: Borm & Assoc,lnc/Suncoast Post Tension LP Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips Sgoo psi to 33.04 kips/33,000 lbs Calibration Date: Machine #38 S Phase Lot# 6 Product L Plan a\1 G (� a 3 e �, cz c_ o.C✓ �. Ca u t \' Weather: Suno Unresolved Items: ,24None ❑ See Below Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 11 h/SN2. L4 ' to YesNo 4) 4 r�_C% 7 e+ r. n ' i n"7 ` 5'T I I LTJ ❑ MCI Er 1:1 r� c c—;z\- ., rwn -- ca off, 3 ❑ j� \ Kr ❑ 4 VAll Ell -1:1 ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued t project completion. 1 Inspector: Jack C. Millin ICC Certi tcatio IV :0842216-89 Contracttoor's Reepre entative: Copy 1 JCM Inspections Copy 2�Project Superintendent Copy 3 Governing Agency Page of JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 9/25/05 Project: Trilogy @ La Quinta - Shea Homes 81-260 Avenue 62 La Quinta, CA 92274 Project No: 02-1109 Set ID Structure Age of Test Compression Strength JCM ID Location Date Cast Cylinder ID (days) (psi) Set A Phase 11 B - Lot # 4146 Slab on Grade 6-27-05 Concrete 273-535 Bedroom 2 Page 1 of 1 Required psi: 4000 512 7 3340 513 28 4720 514 28 4770 CERTIFIED: C , 117\U -V, - Inspections supplies the service of compression strength test results only. Per ASTMC39 10/10/2005 13:15 FAX PARAGONPSCHIMID 19002/008 INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California; in the building at 61-153 DESERT SAGE CT, LOT 4146, PHASE 11 B, LA QUINTA, CA CEILINGS: TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-38 WALLS: TYPE: BLOW MANUFACTURER: Certainteed THICKNESS:. R-13 GENERAL CONTRACTOR: SHEA HOMES LICENSE # BY, TITLE: PARAGO CHMID BUIL NG PRODUCTS A MASCO Company LICENSE # 221517 BY: TITLE: ACCOUNT REPRESENTIVE DATE: I� y