Loading...
04-4714 (BLCK)BUILDING & SAFETY DEPARTMENT P.O. Box 1504 (760).777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA; CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number . . . . . Property Address . . . . . . APN: Application description . . . Property Zoning . . . . . . . Application.valuation 0.4 - 0 4_7-1-4 Date 60-543 DESERT SHADOWS DR 764-270-999-88 -300231- WALL/FENCE MEDIUM HIGH DENSITY RES. d 7 1 1 6/10/04 Owner Contractor SHEA LA QUINTA SHEA HOMES, INC. .0/O JEFF MCQUEEN 81260 AVENUE 62 8800 N GAINEY CENTER 350 LA QUINTA CA 92253 SCOTTSDALE AZ 85258 (760) 777-6005 WCC: NTL UNION INS WC: 7165833 08/01/04 CSLB: 672285 06/30/05 CCC: B ----------------------------------------------------------------------------- Permit . . . . . WALL/FENCE PERMIT Additional.desc Permit Fee . . . 72.00 Plan Check Fee .00 Issue Date Valuation . . . . 4713 Qty Unit Charge Per. 'Extension BASE ,FEE: ;t,„' 45.00 3.00 9.0000 THOU '•BLDG 2,'0'0'1-25, 000 27.00 =-------=------------------------------------------------------------------- Special Notes and Comments 145 L.F. 6 ' GARDEN WALL , 6 8 L.F. 3 ' RETAINING WALL, BOTH ORCO SYSTEM Fee summary ----------------- Permit Fee Total Plan Check Total Grand Total Charged 72.00 - .00 72.00 Paid .00 .00 .ob Credited Due .00 72.00 .Ob .00 .00• 72.00 JUN 1 7 2004 P.O. BOX 1504_ • VOICE (760) 777-701: 78-495 CALLE TAMPICO FAX (760) 777-701 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-71 c. BUILDING &, SAFETY DEPARTMENT Application Number: o 4 " 47/1-1 1 Date: Applicant: Applicant's Mailing Architect or Engineer: Architect or Engineer's Address: A Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under arty of perjury that I am licensed un rovi ons of C pair 9 (coTWcing with Section 7000) of Division 3 of the Business and Professionals Code, and my Ucens full force and effect. /Ccense Class License No 77 Date P, LO ` ontractorOWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish. or repair any structure, prior to its issuance. also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work. and the structure is not intended or offered for safe (Sec. 7044. Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon. and who does the work himself or herself or through his or her own employees. provided that the improvements are not intended or offered for sale. If, however. the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. . BA P.C. for this reason Date • Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation. as provided for by Section 3700 of the Labor Code. for the perforrnance 1i of the work for which this permit is issued. and %gitl 9faintain work' compensatiorfinsurancg, / _ I certify that, in the performance of the work for which this permit is issued. I shall not employ any person in any manner so as to become subject to the workers' compensation laws of Califomi nd agr that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shell forthwith comply with those vi on . �at icant r WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO. ONE HUNDRED THOUSAND DOLLARS ($100.000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE. INTEREST. AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I Hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lenders Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a pernit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of Le Quints, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 dsyi from date of issuance of such permit. or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is co I agree to comply with all city and county ordinances and state laws retailing to building construciior�•an � re=Signature entatives of this county ter upon above-rtrentioned property for inspection purposes. ' Date //JJvv�p pplicant or Agent): CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING TD & TXV) CF-4R Page 1 of 1 PROJECT INFORMATION CZ. 15 Project Tltls: Trilogy Project Address: 60th St & Monroe, La Quinta, CA Builder Name: Shea Homes Voice # Builder Contact: Chrtopher Nevins Voice 760-777.6026 Project ID # : Tract # 30023 Phase #: Macro Lot #. 1088 Plan * 5505 Address: 60543Desert Shadow Drive Conditioned Floor Area: Square Feet HERS RATER & HERS PROVIDER INFORMATI N HERS Rater. Scott Johnson Joyme Carden Certification 0: CCNSJ614037 CCNJC615157 HERS Firm: Action Now Voice 0: 949-631-2274 Address: 2575 Westminster Avenue, Costa Mesa, CA 92627 HERS Provider: CHEERS Voice #; 800-424-3377 HERS Address: 9400 Topanga Canyon Blvd„ Chatsworth, CA 91311 HERS RATER COM LIANCL STA NT The house / unit was; Tested / Verfied x Approved as a part of sample, but was not Tested / Verified No Diagnostic Credits have been taken (visual inspections only) x The installer has provided a copy of CF-6R x T-24 Compliance Credit was Taken for Tight Ducts KAir Distribution System is Fully Ducted (sheetmetal, ductboard or Rex duct) ]Where cloth backed rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at the connections. COOLING System 1 tem 2 System 3 System 4 System 5 System Nominal Cooling Tons 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.08) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity In Nominal Tons) x (0.06) 0 0 0 Measured Fan Flow 0 0 0 0 uct Pressurization Test Results (CFM a 25 PA) 100 x Test Leakage / Fan Flow = % Leakage #DIV/0! #DIV/0! #DIV101 ODIV/01 I $DIV/0! I #DIV101 Check Box for Pass or Fail (Pass = 0% or Less) =T-24 Compliance Credit was Taken for TXV (Installed - Y / N) HEATING System 1 System System 3 System 4 System 5 system Heating Capacity In Thousands of Output BTU per hour 21.7 x Heating Capacity In 1000's of Output BTU per hour 0.0 0.0 0.0 0.0 21.7 x (Heating Cap. in 1000's of Output BTU per hour) x (0.06) 0.0 0.0 0.0 0.0 0.0 Duct Pressurization Test Results (CFM @ 25 PA) 100 x Test Leakage / Fan Flow = % Leakage J 1 /0! #DfV/0! Pass or Fail (Pass = 6% or Less) NOTES: TXV are Installed on all systems in this house even if compliance cmdlt was not taken for the TXV. U Raters Certifying Signature Date 11/10/2004 F2001-02 (4-02) Action Now T-24 CF-4Rmacroads 02/09/2002 03:17 17607769980 HOLLY PAGE 02 INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at 60-543 DESERT SHADOWS DRIVE LOT'f0$8,tAQUINTA CA CEILINGS: TYPE: BLOW r WALLS: ' TYPE: BLOW MAUNFACTURER: Certainteed MANUFACTURER: Certainteed THICKNESS: R-38 THICKNESS: R-13 GENERAL CONTRACTOR: SHEA HOMES LICENSE # BY: TITLE: PARAGON SCHMID BUILDING 0 A MASCO Company LICENSE # 2215 TITLE: ACCOUNT REPRESENTIVE DA .-. ,.,.,:7:'/. .. .: v,v,:Y..,;..•.:..,,........:•r.••:�-•+•�r7.:r.'•nrl.•7"rel,T.,.�I;•:,r�rlJl.,f'.rl.'r1YR>.�,,•,;;•i•,.:•/yin%.:c.r-"':•r:...r:•r.'•R. i:��.:�•... i INSULATION CERTIFICATE I I I • I I I at i i This is to c that insulation has been installed in conformance with the ent energy regulation, Califo Administrative Code, Title 24, State of Callfomi • the building locate 0 CEILINGS: TYPE: BLOW MAUNFACT inteed THICKNESS: R-38 WALLS: TYPE: BLOW NFACTURER: Certainteed THICKNESS: R-13 i GENERAL CO ACTOR, SHEA HOMES LIC E# s BY: TITLE: P, GON SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 2 7 BY: TITLE: ACCOUNT REPRESENTIVE DATE: i'/.•/e/'/r///iN!.•/:/•i././.I.•/iI.•I•,.I'!•!f/-!Y/.'/•'.r/'/:/'/•'/."/••%r%i%•%�i.!,%%i/.,�,ri�i.y.�r..wvrY.�Y"i-�i: r.DIY/f•%�ryrl•NYJY.'H/•'/r'//Y/%✓•M?'/1/..!. /.'!r!�/�/•' I I I • I I I at i i Installation Certificate: Residential CF -6R Site Address PERMIT # ..,fTr C-) v v 60-543. Desert Shadow Drive 1. BUILDER INFORMATION Shea Homes - Trilogy - LaQuinta 81260 Ave. 62 La Quinta, CA 92253 INSTALLING CONTRACTOR: 2. PROJECT INFORMATION SUBDIVISION: Trilogy @ La Quinta CITY: La Quinta COUNTY: Riverside WEST PAC AIR CONDITIONING DISTRIBUTION DUCT OR PIPING R - TYPE VALUE Flexible Ductwork Flexible Ductwork in Attic and Will have a R -Value Between Floors of 4.2 or Better I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition, Ihave verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings. 3. HEATING INFORMATION HEATING MANUFACT HEATING UNIT ACTUAL EFF. HEATING EQUIP HEATING EQUIP. MAKE MODEL # AFUE CAPACITY LOAD Furnace Lennox 80UHG4/5X-100 80% 100000 80% 4. COOLING INFORMATION COOLING EQUIP. A/C MANUFACT COMPRESSOR ACTUAL EFF. COOLING EQUIP COOLING MAKE MODEL # SEER CAPACITY LOAD Lennox 13ACC-060 12 The building design heat loss and design heat gain rate have been determined using a method specified in Section 150(h) of the Energy Efficiency Standards, and are two of the criteria used for equipment sizing and selection. &THERMOSTATIC EXPANSION VALVE (TXV): Thermostatic Expansion Valve (or Commision approved equivalent) is installed and access is provided for inspection. Yes ❑ No ❑ N/A ❑ 6. SUBMITTED BY DATE: /0=0 Signature Installing HVAC Contractor �r JCM.11nipe'.ctiqip's, 3972S Garapd, Lane Suite F eil, CA 02211 LT.M.J LJL INSPE:CTIONS- Phone: 760-345-5554 Fax':. 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City:, 81-260 Avenue 62 LOu'inta, CA Title 24 AWS . FV UBC Other: File # D 1.1 A pp# E] D 1.4 Other Client: Sub-Contractorr Shea La Quinta, LLC Sun Coast Tensioning General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc, Inc/Suncoast Post Tension LP Size and Type of Tendons SID &0 III—Z S�tt',Q e,0 0 Cl A Jack Machine Calibration: