Loading...
13-0425 (SFD)44 " P.Ot. BOX 1504 J 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 13-00000425 Property Address: 52135 DESERT SPOON CT APN: 772-410-997-109 -30270 - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: MEDIUM HIGH DENSITY RES Application valuation: 114693 Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Cl a s: A B License No.: 690645 i� Date: b Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 703.1 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does notapply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT 0 Owner: RJT HOMES RNIZ gQ 1425 E UNI RAITYPfRI y �1e7 PHOENIX, A 85034 OEC Contractor: RJT INVESTMENTS INC 1425 E. UNIVERSITY DRIVE PHOENIX, AZ 85034 (602)257-1656 Lic. No.: 690645 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/10/13 WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation; as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is �issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier LUMBERMEN'S UND Policy Number 424430 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section / 700 oft he Labor Cod , I shat) forthwith comply with --those provisions. Date: (� Applicant:/�1��� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. - 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for ISO days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this cou y to nter upon the above-mentioned property�f/orpinspection purposes. Date: l� Signature (Applicant or Agent): �'•//-/'//�vfyllP— r 4i ,t :' LQPERAI[T Application Number . . . . 13-00000425 Structure Information 1,731SF DWELLING/VB/RES-3/CL-A-FR/13D Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 3.00 FIRE SPRINKLERS 13D GARAGE SQ FTG 598.00 NUMBER OF UNITS 1.0.0 1ST FLOOR -SQUARE FOOTAGE 989.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 742.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 692.00 Plan Check Fee 112.45 Issue Date . . Valuation . . . . 114693 Expiration Date 10/07/13 Qty Unit Charge Per Extension BASE FEE 639.50 15.00 3.5000 --------------------------------------------- THOU BLDG 100,001-500,000 ------------------------------- 52.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 87.55 Plan Check Fee 5.47 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/07/13 Qty Unit Charge Per Extension BASE FEE 15.00 1731.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 60.59 598.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 11.96 Permit . . . GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/07/13 Qty Unit Charge Per Extension BASE FEE 15.00 ----------------------------------------------------------------------------- Permit MECHANICAL Additional desc . Permit Fee . . . . 8'1.5'0 Plan Check Fee 5.1`0 Issue Date . . . . Valuation . . . . 0 Application Number . . . . . 13-00000425 Permit . . . . . MECHANICAL Expiration Date . . 10/07/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 11.0000 EA MECH FURNACE >100K 11.00 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 5.00 6.5000 EA MECH VENT FAN 32.50 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit PLUMBING Additional desc . Permit Fee . . . . 146.25 Plan Check Fee 9.14 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/07/13 Qty Unit Charge Per Extension BASE FEE 15.00 13.00' 6.0000 EA PLB FIXTURE 78.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00. 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000.EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB'LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 1,731SF DWELLING - PLAN SF3BSG, LOT 109 [V]3/RES-3/CLASS A-FR/13D/ENGINEERED] THIS PERMIT DOES NOT INCLUDE.BLOCK WALLS OR WATER FEATURES ***75% REDUCTION TO PLAN`CHECK FEES DUE TO MULTIPLE ISSUANCE OF PLAN TYPE*** 2010 CALIFORNIA BUILDING CODES. April 8, 2013 8:53:13 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 20.00 BLDG STDS ADMIN (SB1473) 5.00 DIF COMMUNITY CENTERS -RES 104.00 DIF CIVIC CENTER - RES 1089.00 ENERGY REVIEW FEE 11.25 DIF FIRE PROTECTION -RES 612.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 334.00 MULTI -SPECIES (MSHCP) FEE 521.00 DIF'PARR MAINT FAC - RES 51.00 DIF PARKS/REC - RES 1773.00 LQPEFN1IT Application Number . . . . . 13-00000425 7 --------------------------------------------------------------------------- Other Fees . . . . . . . STRONG MOTION (SMI) - RES 11.47 DIF STREET MAINT FAC -RES 158.00 DIF TRANSPORTATION - RES 3592,00 Fee summary Charged ---------- Paid. Credited ----------------------- Due ------- ----------------- Permit'Fee Total 1022.30 .00 .00 1022.30 Plan Check Total 132.16 .00 .00 132.16 Other Fee Total 8281.72 .00 .00 8281.72 Grand Total 9436.18 .00 .00 9436.18. LQPERMIT PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUSIDOUX CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 RIVERSIDE COUNTY FIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org July 8, 2013 Symons Fire Protection �Refe�ence LAQ-n1.3=-RS=013 for pl S 1050 Pioneer Way Suite R EI Cajon, CA 92020 Re: Residential Fire Sprinkler Plan Review LAQ-13-RS-040 52-135 Desert Spoon Court La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: A minimum of three spare fire sprinklers of each type and temperature rating along with a sprinkler wrench should be located in a spare head cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all control valves. A warning sign, with minimum'/ inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this•home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (b) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Departure t to schedu a inspection Sincerely, Jaso tubble Fire Safety Specialist